1
|
Ferguson TJ, Samuelson TW, Herndon L, Terveen DC, Bacharach J, Brubaker JW, Berdahl JP, Radcliffe NM. Negative Pressure Application by the Ocular Pressure Adjusting Pump to Lower Intraocular Pressure in Normal-Tension Glaucoma: HERCULES Study. Am J Ophthalmol 2025; 275:121-134. [PMID: 40147597 DOI: 10.1016/j.ajo.2025.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Revised: 03/16/2025] [Accepted: 03/17/2025] [Indexed: 03/29/2025]
Abstract
PURPOSE To evaluate the safety and intraocular pressure (IOP)-lowering efficacy of the ocular pressure adjusting pump in subjects with normal-tension glaucoma (NTG). DESIGN Prospective, multicenter, masked, randomized, fellow-eye controlled trial. SUBJECTS, PARTICIPANTS, AND/OR CONTROLS Subjects with NTG with an IOP ≥12 mm Hg and ≤21 mm Hg were enrolled. One eye of each subject was randomized to receive negative pressure application; the fellow eye served as a control. METHODS Subjects wore the device overnight for 1 year and the applied negative pressure was programmed by subtracting a reference IOP of 6 mm Hg from the baseline IOP. MAIN OUTCOME MEASURES The primary effectiveness endpoint was the proportion of eyes achieving an IOP reduction ≥20% at Week 52 during the day. The secondary endpoint was the proportion of eyes achieving a nocturnal IOP reduction ≥20% at Week 52. Exploratory endpoints included mean IOP reduction in clinic and in the sleep lab. RESULTS A total of 186 eyes were randomized across 11 sites. 120 eyes successfully completed all visits across 52 weeks without protocol deviations. At Week 52, 88.3% (n = 53) of study eyes vs 1.7% (n = 1) of control eyes met the primary endpoint. For the secondary endpoint, 96.7% (n = 58) of study eyes vs 5.0% (n = 3) met the endpoint. For exploratory IOP analysis, the mean nocturnal IOP reduction at Week 52 was 8.0 mm Hg (39.1%) from a baseline of 20.4 ± 2.5 mm Hg to 12.4 ± 2.7 mm Hg. There were no serious adverse events. The most commonly reported adverse events were lid (11.8% study, 1.1% control) and periorbital edema (12.9%, 1.1%). CONCLUSIONS The ocular pressure adjusting pump safely and effectively lowers both daytime and nocturnal IOP in patients with NTG.
Collapse
Affiliation(s)
- Tanner J Ferguson
- From the Vance Thompson Vision (T.J.F., D.C.T., and J.P.B.), Sioux Falls, South Dakota, USA.
| | | | - Leon Herndon
- Duke Eye Center (L.H.), Durham, North Carolina, USA
| | - Daniel C Terveen
- From the Vance Thompson Vision (T.J.F., D.C.T., and J.P.B.), Sioux Falls, South Dakota, USA
| | - Jason Bacharach
- North Bay Eye Associates (J.B.), Sonoma County, California, USA
| | - Jacob W Brubaker
- Sacramento Eye Consultants (J.W.B.), Sacramento, California, USA
| | - John P Berdahl
- From the Vance Thompson Vision (T.J.F., D.C.T., and J.P.B.), Sioux Falls, South Dakota, USA
| | | |
Collapse
|
2
|
Huang AS, Mai AP, Goldberg JL, Samuelson TW, Morgan WH, Herndon L, Ferguson TJ, Weinreb RN. The Benefit of Nocturnal IOP Reduction in Glaucoma, Including Normal Tension Glaucoma. Clin Ophthalmol 2024; 18:3153-3160. [PMID: 39525872 PMCID: PMC11550682 DOI: 10.2147/opth.s494949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Accepted: 10/29/2024] [Indexed: 11/16/2024] Open
Abstract
Nocturnal intraocular pressure (IOP) profiling has shown that the peak IOP usually occurs at night, particularly in patients with glaucoma. Multiple studies have demonstrated that these nocturnal IOP elevations drive glaucomatous progression, often despite stable daytime IOP. Existing vascular dysregulation and decreased nighttime blood pressure compound the damage via low ocular perfusion pressure while elevated nocturnal IOP disrupts axonal transport. These findings are consistent with studies that indicate lowering nocturnal IOP is important for slowing glaucoma progression. Many of the current treatment options lower nighttime IOP significantly less than daytime IOP. Non-invasive IOP-lowering treatments that effectively lower nocturnal IOP remain an unmet need in the treatment of glaucoma.
Collapse
Affiliation(s)
- Alex S Huang
- Doheny Eye Institute, Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | | | - Jeffrey L Goldberg
- Byers Eye Institute, Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Thomas W Samuelson
- Minnesota Eye Consultants, University of Minnesota, Minneapolis, MN, USA
| | - William H Morgan
- Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, Western Australia, Australia
| | - Leon Herndon
- Department of Ophthalmology, Duke Eye Center, Duke University, Durham, NC, USA
| | | | - Robert N Weinreb
- Hamilton Glaucoma Center, Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA, USA
| |
Collapse
|
3
|
Atar-Vardi M, Dubinsky-Pertzov B, Shemer A, Hecht I, Pras E, Einan-Lifshitz A, Or L. Behavior of biometric parameters during clinical hours. J Fr Ophtalmol 2024; 47:104296. [PMID: 39341042 DOI: 10.1016/j.jfo.2024.104296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 05/09/2024] [Accepted: 06/05/2024] [Indexed: 09/30/2024]
Abstract
PURPOSE To evaluate and quantify variation of biometric parameters - axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT) and white-to-white (WTW). METHODS A population-based retrospective cohort study was performed on patients who underwent a biometry test prior to cataract surgery using the IOL Master 700 (Carl Zeiss Meditec, Jena, Germany) between the years 2017-2021. Differences in these parameters were evaluated between scans executed at different times of the day. RESULTS 21,975 examinations of 8611 patients were included. Mean age was 70.50±12.56years. The mean time of the biometry exams was 10:52±1:23 AM. Measurements of AL, ACD, CCT and WTW were tested hourly and grouped between 7:00-9:00 AM and 12:00-03:00 PM. All the parameters showed a diurnal increase with a significance of P<0.001 (AL from 23.64±1.5 to 24.01±1.76mm; ACD from 3.29±0.67 to 3.35±0.64mm; CCT from 0.52±0.04 to 0.53±0.04μm and WTW from11.83±0.46 to 11.90±0.51mm). The most significant change was seen in AL. The difference between time groups remained significant in a generalized linear mixed model (P<0.001). CONCLUSIONS There are fluctuations in AL, ACD, CCT, WTW measurements during office hours. These results raise questions about the significance of timing of the biometry exam and the effect on the ELP calculation.
Collapse
Affiliation(s)
- M Atar-Vardi
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - B Dubinsky-Pertzov
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - A Shemer
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - I Hecht
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - E Pras
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - A Einan-Lifshitz
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - L Or
- Department of Ophthalmology, Shamir Medical Center, Zerifin, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
4
|
Samuelson TW, Ferguson TJ, Brubaker JW, Bacharach J, Gallardo MJ, Chaglasian M, Comer G, Yoo P. Negative Pressure Application via a Multi-Pressure Dial to Lower IOP in Patients with Suspected Glaucoma or Open Angle Glaucoma. J Glaucoma 2023; 32:708-720. [PMID: 37171994 DOI: 10.1097/ijg.0000000000002231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 04/16/2023] [Indexed: 05/14/2023]
Abstract
PRCIS The multi-pressure dial applies localized periocular negative pressure to safely and effectively lower IOP and represents the first non-invasive, non-pharmacologic device for IOP reduction. OBJECTIVE To evaluate the safety and effectiveness of the Multi-Pressure Dial (MPD) system, a device that applies periocular negative pressure to lower intraocular pressure (IOP). SETTING 6 investigational sites, United States. DESIGN Prospective, assessor-masked, randomized controlled trial. METHODS Subjects with suspected glaucoma, ocular hypertension (OHTN), and open angle glaucoma (OAG) with baseline IOP ≥13 mmHg and ≤32 mmHg were enrolled. One eye of each subject was randomized to receive negative pressure application; the fellow eye served as a control. The study eye negative pressure setting was programmed for 60% of the baseline IOP. The primary effectiveness endpoint was the proportion of study eyes versus control eyes achieving an IOP reduction ≥20% at Day 90. Secondary endpoints included the proportion of eyes achieving an IOP reduction ≥25% at Day 90 as well as the proportion of eyes achieving an IOP reduction ≥20% at Days 30 and 60. RESULTS 116 eyes of 58 subjects completed the study. At the Day 90 visit, 89.7% ( n =52) of study eyes versus 3.4% ( n =2) of control eyes achieved an IOP reduction ≥20% ( P <0.001). At Day 90, 77.6% ( n =45) of study eyes achieved a ≥25% IOP reduction compared to 1.7% ( n =1) of control eyes ( P <0.001). The most commonly reported adverse events were lid (17.2% study eye, 7.8% control eye) and periorbital edema (14.1% study eye, 10.9% control eye). CONCLUSIONS This trial demonstrates that the MPD safely and effectively lowers IOP in a group of patients that included glaucoma suspects, OHTN, and patients with OAG.
Collapse
Affiliation(s)
| | | | | | | | - Mark J Gallardo
- El Paso Eye Surgeons, El Paso, TX, USA
- University of Texas Health Sciences Center, San Antonio, TX, USA
| | | | - George Comer
- Southern California College of Optometry, Fullerton, CA, USA
| | - Paul Yoo
- Equinox Ophthalmic, Inc., Newport Beach, CA, USA
| |
Collapse
|
5
|
Shi Y, Zhang Y, Sun W, Huang AS, Chen S, Zhang L, Wang W, Xie L, Xie X. 24-Hour efficacy of single primary selective laser trabeculoplasty versus latanoprost eye drops for Naïve primary open-angle glaucoma and ocular hypertension patients. Sci Rep 2023; 13:12179. [PMID: 37500642 PMCID: PMC10374636 DOI: 10.1038/s41598-023-38550-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 07/10/2023] [Indexed: 07/29/2023] Open
Abstract
This prospective, observer-masked, randomized clinical trial was conducted between December 2018 and June 2021 at Eye Hospital, China Academy of Chinese Medical Sciences. A total of 45 glaucoma patients from Beijing, China, were enrolled in this clinical trial to compare the short-term efficacy of primary single-selective laser trabeculoplasty (SLT) to 0.005% latanoprost eye drops for the treatment of 24-h intraocular pressure (IOP) in patients with newly diagnosed primary open angle glaucoma (POAG) and ocular hypertension (OHT). Both SLT and latanoprost significantly decreased mean 24-h IOP and peak IOP, although the latanoprost group effect was more potent when compared to the SLT group (both Ps < 0.05). Compared with the SLT group, the latanoprost group had a significant and stable decrease in IOP after treatment. The latanoprost group had a more pronounced reduction in IOP at weeks 4 and 12 (P < 0.05) but had no difference at week 1 (P = 0.097). As a first-line treatment, both SLT and latanoprost eye drops are effective in newly diagnosed POAG and OHT patients. However, the latanoprost eye drops may be better in decreasing mean and peak 24-h IOP and thus controlling 24-h IOP fluctuation compared to SLT.
Collapse
Affiliation(s)
- Yipeng Shi
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China
| | - Yan Zhang
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China
| | - Wenying Sun
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China
| | - Alex S Huang
- Hamilton Glaucoma Center, The Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, CA, USA
| | - Shuang Chen
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China
- China Academy of Chinese Medical Sciences, Beijing, China
| | - Lixia Zhang
- China Academy of Chinese Medical Sciences, Beijing, China
| | - Wei Wang
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China
| | - Like Xie
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China
| | - Xiaobin Xie
- Eye Hospital, China Academy of Chinese Medical Sciences, 33 Lugu Road, Shijingshan District, Beijing, 100040, China.
| |
Collapse
|
6
|
Pajic B, Resan M, Pajic-Eggspuehler B, Massa H, Cvejic Z. Triggerfish Recording of IOP Patterns in Combined HFDS Minimally Invasive Glaucoma and Cataract Surgery: A Prospective Study. J Clin Med 2021; 10:3472. [PMID: 34441768 PMCID: PMC8396965 DOI: 10.3390/jcm10163472] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 07/30/2021] [Accepted: 08/04/2021] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The aim of the study is to investigate whether the circadian IOP rhythm can be influenced by combined cataract surgery with high frequency deep sclerotomy (HFDS) and whether intraocular pressure (IOP) can be significantly reduced by HFDS. METHODS In our study 10 patients were included, in whom 24 h IOP monitoring was installed before and after HFDS/cataract surgery using a Triggerfish. HFDS is a minimally invasive glaucoma surgery (MIGS). RESULTS After performed HFDS combined with cataract surgery, the IOP was reduced from 27.7 ± 2.11 mmHg to 14.4 ± 2.59 mmHg, which is highly significant (p < 0.001). The contact lens sensor (CLS) cosinor analysis pre- and postoperatively showed that the circadian rhythm is not influenced by the surgery, i.e., the circadian IOP rhythm did not show significant differences before and after surgery. CONCLUSIONS HFDS combined with cataract surgery is a potent surgical method that can significantly reduce the IOP. However, the circadian rhythm cannot be changed by the surgery. The acrophase remained during the night in all patients.
Collapse
Affiliation(s)
- Bojan Pajic
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach AG, Switzerland;
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, 1205 Geneva, Switzerland;
- Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia;
| | - Mirko Resan
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia;
| | | | - Horace Massa
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, 1205 Geneva, Switzerland;
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
| |
Collapse
|
7
|
Landers J. Selective laser trabeculoplasty: A review. Clin Exp Ophthalmol 2021; 49:1102-1110. [PMID: 34331388 DOI: 10.1111/ceo.13979] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 07/09/2021] [Accepted: 07/15/2021] [Indexed: 11/24/2022]
Abstract
Glaucoma is the second most prevalent cause of blindness worldwide, and the only effective management is the lowering of intraocular pressure (IOP). Selective laser trabeculoplasty (SLT) has become an essential part of glaucoma management since its commercial release in 2001. It has been an improvement from the previous argon laser trabeculoplasty (ALT), by using 1% of the laser energy, reducing the amount of anterior segment inflammation and minimising the degree of mechanical injury to the trabecular meshwork. There is now a large volume of work that demonstrates SLT is equally effective as ALT and topical medication in lowering IOP. It is simple to perform, with a well described side-effect profile, and is long-lasting and repeatable. This review will summarise the current literature on SLT for each of these topics.
Collapse
Affiliation(s)
- John Landers
- Department of Ophthalmology, Flinders Medical Centre, Adelaide, South Australia, Australia
| |
Collapse
|
8
|
The Utility of iCare HOME Tonometry for Detection of Therapy-Related Intraocular Pressure Changes in Glaucoma and Ocular Hypertension. Ophthalmol Glaucoma 2021; 5:85-93. [PMID: 34082179 DOI: 10.1016/j.ogla.2021.05.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 04/30/2021] [Accepted: 05/21/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE To assess whether iCare HOME rebound tonometry can detect therapy-related changes during self-monitoring of intraocular pressure (IOP). DESIGN Prospective clinical trial. PARTICIPANTS A total of 43 eyes (n = 27 subjects) with open-angle glaucoma or ocular hypertension were enrolled during standard-of-care clinic visits. Participants were grouped into control eyes managed on stable therapy (n = 18 eyes) or therapy change eyes undergoing selective laser trabeculoplasty (SLT, n = 8 eyes), initiating topical therapy (n = 8 eyes), or adding a second medication to existing monotherapy (n = 9 eyes). METHODS Subjects recorded IOP 4 times daily for 1 week using iCare HOME tonometry. Upon tonometer return, subjects underwent SLT or new medication start; an additional week of iCare HOME measurements was collected after 4 to 6 weeks. Control subjects recorded an additional week of measurements after 6 weeks. Measurements were grouped into 4 time periods (5-10 am, 10 am to 3 pm, 3-8 pm, 8 pm to 1 am). Goldmann applanation tonometry (GAT) was performed at each study visit for comparison. MAIN OUTCOME MEASURES Detection of therapy response defined as an IOP reduction of ≥20%. RESULTS For eyes that demonstrated a therapy response by GAT (n = 11), iCare HOME detected a therapy response in 90.9% of eyes in ≥1 time period and 45.5% of eyes in all 4 time periods. In eyes without a GAT-measured therapy response (n = 14), iCare HOME detected a response for 71.4% (n = 10) of eyes in ≥1 time period and for 7.1% of eyes (n = 1) at all 4 time periods. In treatment eyes, intraday and interday average minimum and maximum IOP, as well as interday IOP range, were significantly reduced after therapy without a significant change in intraday IOP range. Control group eyes did not demonstrate a significant change in average IOP minimum, maximum, or range between study weeks. CONCLUSIONS Home tonometry with iCare HOME reliably detects therapy-related IOP changes in patients with glaucoma and ocular hypertension. Treatment responses correlated well with in-office GAT and may detect treatment responses missed by GAT. Intraocular pressure measurements via home tonometry provide additional clinical information regarding intraday and interday IOP fluctuation beyond standard of care in office GAT measurements. The iCare HOME is a valuable tool to monitor therapeutic efficacy in patients with glaucoma.
Collapse
|
9
|
Short-term Evaluation of Negative Pressure Applied by the Multi-Pressure Dial System to Lower Nocturnal IOP: A Prospective, Controlled, Intra-subject Study. Ophthalmol Ther 2021; 10:349-358. [PMID: 33871812 PMCID: PMC8079468 DOI: 10.1007/s40123-021-00343-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 03/26/2021] [Indexed: 12/19/2022] Open
Abstract
Introduction The purpose of this study was to investigate the short-term safety and feasibility of negative pressure application by the Multi-Pressure Dial (MPD) System to lower nocturnal intraocular pressure (IOP) in subjects with open-angle glaucoma (OAG). Methods A prospective, controlled, intra-subject study of 22 eyes from 11 subjects at a single site was performed. All subjects had a history of OAG and were currently using a topical prostaglandin. For each subject, the eye with the highest IOP in the supine position was selected as the treatment eye (TE) and the contralateral eye served as the control eye (CE). The negative pressure for the TE was set to 60% of the baseline IOP value with no negative pressure in the CE. IOP measurements were collected at three prespecified time points overnight in the supine position with active negative pressure. The primary outcome measure was mean IOP with the application of negative pressure. Results At the three overnight time points, the mean (± standard deviation) baseline IOP prior to negative pressure application was 22.2 ± 2.5 mmHg in the TE and 21.8 ± 2.5 mmHg in the CE. With the application of 60% negative pressure to the TE and no active negative pressure to the CE, the mean IOP was 14.2 ± 2.2 and 19.5 ± 2.4 mmHg, respectively. The mean percentage IOP reduction in the TE was 35% (p < 0.001). There were two minor adverse events, both unrelated to device wear, and there were no IOP spikes ≥ 10 mmHg. Conclusion The MPD can safely and effectively lower nocturnal IOP in the supine position. The MPD holds promise as a potential new, non-invasive treatment option for the control of nocturnal IOP.
Collapse
|
10
|
Neroev V, Malishevskaya T, Weinert D, Astakhov S, Kolomeichuk S, Cornelissen G, Kabitskaya Y, Boiko E, Nemtsova I, Gubin D. Disruption of 24-Hour Rhythm in Intraocular Pressure Correlates with Retinal Ganglion Cell Loss in Glaucoma. Int J Mol Sci 2020; 22:359. [PMID: 33396443 PMCID: PMC7795318 DOI: 10.3390/ijms22010359] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 12/27/2020] [Accepted: 12/28/2020] [Indexed: 02/08/2023] Open
Abstract
Parameters of 24-h rhythm in intraocular pressure (IOP) were assessed in patients with stable or advanced primary open-angle glaucoma (S-POAG/A-POAG) and referenced to the phase of "marker" circadian temperature rhythm of each patient. Body temperature and IOP were measured over a 72-h span in 115 participants (65 S-POAG and 50 A-POAG). Retinal Ganglion Cell (RGC) damage was assessed by high-definition optical coherence tomography. The 24-h IOP rhythm in A-POAG patients peaked during the night, opposite to the daytime phase position in S-POAG patients (p < 0.0001). The 24-h IOP phase correlated with RGC loss (p < 0.0001). The internal phase shift between IOP and body temperature gradually increased with POAG progression (p < 0.001). Angiotensin converting enzyme Alu-repeat deletion/insertion (ACE I/D) emerged as a candidate gene polymorphism, which may play a role in the alteration of the circadian IOP variability in advanced glaucoma. To conclude, a reliable estimation of the 24-h rhythm in IOP requires the degree of RGC damage to be assessed. In advanced POAG, the 24-h phase of IOP tended to occur during the night and correlated with RGC loss, being progressively delayed relative to the phase of temperature.
Collapse
Affiliation(s)
- Vladimir Neroev
- Helmholtz Research Institute of Eye Diseases, 105062 Moscow, Russia; (V.N.); (T.M.)
| | | | - Dietmar Weinert
- Institute of Biology/Zoology, Martin Luther University, 06108 Halle-Wittenberg, Germany;
| | - Sergei Astakhov
- Department of Ophthalmology, Pavlov First Saint Petersburg State Medical University, 197022 St. Petersburg, Russia;
| | - Sergey Kolomeichuk
- Laboratory of Genetics, Institute of Biology of the Karelian Science Center of the Russian Academy of Sciences, 185910 Petrozavodsk, Russia;
| | - Germaine Cornelissen
- Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN 55455, USA;
| | - Yana Kabitskaya
- Сenter for Genomic Technologies, Northern Trans-Ural State Agricultural University, 625003 Tyumen, Russia; (Y.K.); (E.B.)
| | - Elena Boiko
- Сenter for Genomic Technologies, Northern Trans-Ural State Agricultural University, 625003 Tyumen, Russia; (Y.K.); (E.B.)
| | - Irina Nemtsova
- State Autonomous Health Care Institution Tyumen Regional Ophthalmological Dispensary, 625048 Tyumen, Russia;
| | - Denis Gubin
- Department of Biology, Medical University, 625023 Tyumen, Russia
- Tyumen Cardiology Research Center, Tomsk National Research Medical Center, Russian Academy of Science, 634009 Tomsk, Russia
| |
Collapse
|
11
|
Chen X, Wu X, Lin X, Wang J, Xu W. Outcome, influence factor and development of CLS measurement in continuous IOP monitoring: A narrative review. Cont Lens Anterior Eye 2020; 44:101376. [PMID: 33092960 DOI: 10.1016/j.clae.2020.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 09/25/2020] [Accepted: 10/08/2020] [Indexed: 10/23/2022]
Abstract
A large fluctuation in intraocular pressure (IOP) and a high peak IOP remain the risk factors for progressive visual field loss in patients with glaucoma, which is a leading cause of irreversible blindness. However, IOP measurements during working time cannot provide sufficient information on IOP to guide clinicians in setting IOP target values. Contact lenses are extensively used in ophthalmology to correct the refractive error, and recently, they are serving as platforms for detection and drug delivery. Contact lens sensor (CLS) is a feasible and promising approach to continuously monitor IOP, with superior tolerance, non-invasiveness, and without sleep disturbance. The present work reviewed the associations between progressive course and Triggerfish® CLS outputs as well as the relationship between treatments and Triggerfish® CLS outputs. Moreover, it further summarized state-of-the-art CLS devices of the past decade.
Collapse
Affiliation(s)
- Xiang Chen
- The Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China
| | - Xingdi Wu
- The Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China
| | - Xueqi Lin
- The Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China
| | - Jingwen Wang
- The Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China
| | - Wen Xu
- The Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China.
| |
Collapse
|
12
|
Ferguson TJ, Radcliffe NM, Van Tassel SH, Baartman BJ, Thompson VM, Lindstrom RL, Ibach MJ, Berdahl JP. Overnight Safety Evaluation of a Multi-Pressure Dial in Eyes with Glaucoma: Prospective, Open-Label, Randomized Study. Clin Ophthalmol 2020; 14:2739-2746. [PMID: 33061256 PMCID: PMC7518782 DOI: 10.2147/opth.s256891] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 08/12/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose To investigate the safety and tolerability of the multi-pressure dial (MPD) worn overnight for seven consecutive days. Design Prospective, open-label, randomized, single-site study. Subjects Twenty eyes of 10 subjects with open-angle glaucoma were fitted with an MPD and randomized to negative pressure application of −10 mmHg in one eye (study eye) worn overnight for 7 consecutive days. Methods Safety measures included best-corrected visual acuity (BCVA), intraocular pressure (IOP) changes from baseline during and after negative pressure application, slit lamp and dilated fundus exam findings, and rate of adverse events. Subjective assessments were completed daily by the subjects during the 7-day study period and immediately following the study period. Results Prior to the 7-day testing period, application of 10 mmHg negative pressure reduced mean IOP from 18.2 ± 3.8 mmHg to 14.0 ± 2.1 mmHg (p<0.01), a 22% reduction. After 7 days of consecutive nightly wear, repeat IOP measurements with the application of negative pressure showed a decrease in mean IOP from 16.9 ± 4.3 mmHg to 13.5 ± 3.7 mmHg. The observed IOP reduction was in addition to the subjects’ current treatment regimen. There were no statistically significant changes in IOP, BCVA from baseline following the 7-day period of nightly wear with the application of negative pressure. The patient-reported outcomes were favorable. Conclusion The MPD can safely and comfortably be worn overnight. The decrease in IOP of >20% in addition to current therapy is both clinically and statistically significant. The MPD shows promise as a potential new treatment option for nocturnal IOP control.
Collapse
Affiliation(s)
| | | | | | | | | | - Richard L Lindstrom
- Vance Thompson Vision, Sioux Falls, SD, USA.,Minnesota Eye Consultants, Minnesota, MN, USA
| | - Mitch J Ibach
- Vance Thompson Vision, Sioux Falls, SD, USA.,Minnesota Eye Consultants, Minnesota, MN, USA
| | | |
Collapse
|
13
|
Al-Nosairy KO, van den Bosch JJON, Pennisi V, Mansouri K, Thieme H, Choritz L, Hoffmann MB. Use of a novel telemetric sensor to study interactions of intraocular pressure
and ganglion-cell function in glaucoma. Br J Ophthalmol 2020; 105:661-668. [DOI: 10.1136/bjophthalmol-2020-316136] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 05/07/2020] [Accepted: 06/03/2020] [Indexed: 11/03/2022]
Abstract
Aims
(1) To test the feasibility of simultaneous steady-state pattern
electroretinogram (ssPERG) and intraocular pressure (IOP) measurements with an
implanted IOP sensor. (2) To explore the scope of this approach for detecting
PERG changes during IOP manipulation in a model of lateral decubitus
positioning (LDP; lateral position).
Methods
15 healthy controls and 15 treated glaucoma patients participated in the
study. 8 patients had an IOP sensor (Eyemate-IO, Implandata Ophthalmic Products
GmbH) in the right eye (GLAIMP) and 7 had no sensor and
with glaucoma in the left eye. (1) We compared PERGs with and without
simultaneous IOP read-out in GLAIMP. (2) All participants
were positioned in the following order: sitting1 (S1), right LDP
(LDR), sitting2 (S2), left LDP
(LDL) and sitting3 (S3). For each position, PERG
amplitudes and IOP were determined with rebound tonometry (Icare TA01i) in all
participants without the IOP sensor.
Results
Electromagnetic intrusions of IOP sensor read-out onto ssPERG recordings
had, due to different frequency ranges, no relevant effect on PERG amplitudes.
IOP and PERG measures were affected by LDP, for example, IOP was increased
during LDR versus S1 in the lower eyes of
GLAIMP and controls (5.1±0.6 mmHg,
P0.025=0.00004 and 1.6±0.6 mmHg,
P0.025=0.02, respectively) and PERG amplitude was
reversibly decreased (−25±10%, P0.025=0.02 and −17±5%,
P0.025, respectively).
Conclusions
During LDP, both IOP and PERG changed predominantly in the lower eye. IOP
changes induced by LDP may be a model for studying the interaction of IOP and
ganglion-cell function.
Collapse
|
14
|
The Effect of Therapeutic IOP-lowering Interventions on the 24-hour Ocular Dimensional Profile Recorded With a Sensing Contact Lens. J Glaucoma 2020; 28:252-257. [PMID: 30640804 DOI: 10.1097/ijg.0000000000001185] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PRéCIS:: The 24-hour ocular dimensional profile recorded by a contact lens sensor was affected by intraocular pressure lowering interventions. Among different treatments, incisional surgery had the most significant effect. PURPOSE We investigated the effect of different intraocular pressure (IOP)-lowering interventions on contact lens sensor (CLS) parameters and their relationship with Goldmann applanation tonometry (GAT)-measured IOP reduction. METHODS Data from reliable CLS recordings performed before and after IOP-lowering interventions were analyzed. Three interventions were evaluated: topical medications, laser trabeculoplasty, and incisional surgery. A set of 115 different CLS parameters were derived from 24-hour curves. We compared before versus after values for each parameter. In addition, linear regression was performed using the percentage change of each CLS parameter as the outcome variable and the type of IOP-lowering procedure as the predictor after adjusting age and race. Finally, we investigated the relationship between changes in CLS parameters and GAT IOP with the Spearman rank correlation coefficient. RESULTS A total of 182 eyes of 182 patients were included in the analyses: 60 (33%) topical medications, 69 (38%) laser, and 53 (29%) surgery. The mean GAT IOP change was 3.6±6.5 mm Hg (P<0.001). Overall, more CLS parameters had a significant change after surgery than in the other groups (surgery>laser=drug). Linear regression showed that, for 20 CLS parameters, surgery was the most predictive of greatest percentage change in CLS signals. In all, 11 (9.5%) of the CLS parameters were significantly correlated with GAT changes. CONCLUSIONS Incisional glaucoma surgery had a more pronounced effect on GAT and CLS parameters than laser and drugs. The CLS can detect changes in patterns resulting from IOP-lowering interventions beyond daytime GAT IOP. This device could potentially be used to assess treatment efficacy in glaucoma.
Collapse
|
15
|
Review of the measurement and management of 24-hour intraocular pressure in patients with glaucoma. Surv Ophthalmol 2020; 65:171-186. [DOI: 10.1016/j.survophthal.2019.09.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 09/23/2019] [Accepted: 09/25/2019] [Indexed: 02/06/2023]
|
16
|
Gillmann K, Bravetti GE, Niegowski LJ, Mansouri K. Using sensors to estimate intraocular pressure: a review of intraocular pressure telemetry in clinical practice. EXPERT REVIEW OF OPHTHALMOLOGY 2019. [DOI: 10.1080/17469899.2019.1681264] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Kevin Gillmann
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
| | | | | | - Kaweh Mansouri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio, Lausanne, Switzerland
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
| |
Collapse
|
17
|
Xu L, Yu RJ, Ding XM, Li M, Wu Y, Zhu L, Chen D, Peng C, Zeng CJ, Guo WY. Efficacy of low-energy selective laser trabeculoplasty on the treatment of primary open angle glaucoma. Int J Ophthalmol 2019; 12:1432-1437. [PMID: 31544039 DOI: 10.18240/ijo.2019.09.10] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 04/08/2019] [Indexed: 12/20/2022] Open
Abstract
AIM To investigate the efficacy of low-energy selective laser trabeculoplasty (SLT) on the treatment of primary open angle glaucoma (POAG) patients. METHODS Outpatients with POAG who underwent 360-degree SLT using an initial energy of 0.3 mJ (total energy of 30-40 mJ) were reviewed retrospectively from September 2011 to January 2018. RESULTS Eight-six eyes of 44 POAG patients underwent 360-degree SLT using initial energy of 0.3 mJ and were followed up regularly. The total energy used was 32.5±2.5 mJ (23-40 mJ, 105±6 spots). The average pretreatment intraocular pressure (IOP) was 19.8±3.9 mm Hg. At 1, 3, 6mo, 1, and 2y, the post-SLT IOPs (mm Hg) were 16.9±3.3, 16.5±3.3, 17.1±3.4, 16.6±3.5, 16.5±2.8, which were significantly lower than that before treatment (P<0.001). The patients in the SLT success group were found to be younger than those in the SLT failure group. After SLT, 59 eyes that maintained pretreatment medications were defined as the drug retention group. The pre-SLT IOP was 20.1±3.7 mm Hg. At 1, 3, 6mo, 1, and 2y, the post-SLT IOPs (mm Hg) were 17.3±3.6, 16.6±3.5, 17.2±3.6, 16.9±3.8 and 16.5±2.9, respectively. Twenty-seven eyes that required reduced drugs were defined as the drug reduction group. The pre-SLT IOP was 19.2±4.4 mm Hg. At 1, 3, 6mo, 1, and 2y, the post-SLT IOPs (mm Hg) were 16.1±2.6, 16.5±3.1, 16.8±2.9, 16.0±2.6 and 16.3±2.4, respectively. Compared with the pretreatment IOPs, the post-SLT IOPs were significantly lower in drug retention group and drug reduction group. The patients in the drug reduction group were found to be younger than those in the drug retention group. CONCLUSION Low-energy SLT is safe and effective for POAG patients during a 2-year follow-up. Younger POAG patients may obtain better results after low-energy SLT treatment.
Collapse
Affiliation(s)
- Li Xu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Ru-Jing Yu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Xu-Ming Ding
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Mao Li
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Yue Wu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Li Zhu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Di Chen
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Cheng Peng
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Chang-Juan Zeng
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| | - Wen-Yi Guo
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai 200011, China
| |
Collapse
|
18
|
Twenty-Four-Hour Contact Lens Sensor Monitoring of Aqueous Humor Dynamics in Surgically or Medically Treated Glaucoma Patients. J Ophthalmol 2019; 2019:9890831. [PMID: 30809389 PMCID: PMC6369465 DOI: 10.1155/2019/9890831] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2018] [Accepted: 01/10/2019] [Indexed: 11/23/2022] Open
Abstract
Aim This study assessed the 24 h circadian rhythm of intraocular pressure (IOP) using a contact lens sensor in three groups of patients with open-angle glaucoma. Methods This study was a monocentric, cross-sectional, nonrandomized, prospective, pilot study. Eighty-nine patients were enrolled: 29 patients previously underwent an Ex-PRESS mini glaucoma device procedure (Group 1), 28 patients previously underwent Hydrus microstent implantation (Group 2), and 32 patients were currently being treated medically for primary open-angle glaucoma (Group 3). Circadian rhythm patterns were considered with five circadian indicators: fluctuation ranges, maximum, minimum, acrophase (time of peak value), and bathyphase (time of trough value). A two-tailed Mann–Whitney U-test was used to evaluate differences between groups. Results All subjects exhibited a circadian rhythm and a nocturnal pattern. The signal fluctuation range was significantly smaller in the surgical groups than in the medically treated group (Group 1 vs. Group 3, p=0.003; Group 2 vs. Group 3, p=0.010). Subjects who underwent the Ex-PRESS procedure (Group 1) exhibited significant differences compared with the drug therapy group (Group 3) with regard to the minimum value (p=0.015), acrophase (p=0.009), and bathyphase (p=0.002). The other circadian indicators were not significantly different among groups. Conclusions Patients who underwent IOP-lowering surgery had an intrinsic nyctohemeral rhythm. Both surgical procedures, Ex-PRESS and Hydrus, were associated with smaller signal fluctuations compared with medical treatment.
Collapse
|
19
|
Konstas AG, Kahook MY, Araie M, Katsanos A, Quaranta L, Rossetti L, Holló G, Detorakis ET, Oddone F, Mikropoulos DG, Dutton GN. Diurnal and 24-h Intraocular Pressures in Glaucoma: Monitoring Strategies and Impact on Prognosis and Treatment. Adv Ther 2018; 35:1775-1804. [PMID: 30341506 PMCID: PMC6223998 DOI: 10.1007/s12325-018-0812-z] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Indexed: 12/19/2022]
Abstract
The present review casts a critical eye on intraocular pressure (IOP) monitoring and its value in current and future glaucoma care. Crucially, IOP is not fixed, but varies considerably during the 24-h cycle and between one visit and another. Consequently, a single IOP measurement during so-called office hours is insufficient to characterize the real IOP pathology of a patient with glaucoma. To date IOP remains the principal and only modifiable risk factor for the development and progression of glaucoma. Only by evaluating IOP characteristics (mean, peak and fluctuation of IOP) at diagnosis and after IOP-lowering interventions can we appreciate the true efficacy of therapy. Unfortunately, a major limiting factor in glaucoma management is lack of robust IOP data collection. Treatment decisions, advancement of therapy and even surgery are often reached on the basis of limited IOP evidence. Clearly, there is much room to enhance our decision-making and to develop new algorithms for everyday practice. The precise way in which daytime IOP readings can be used as predictors of night-time or 24-h IOP characteristics remains to be determined. In practice it is important to identify those at-risk glaucoma patients for whom a complete 24-h curve is necessary and to distinguish them from those for whom a daytime curve consisting of three IOP measurements (at 10:00, 14:00 and 18:00) would suffice. By employing a staged approach in determining the amount of IOP evidence needed and the rigour required for our monitoring approach for the individual patient, our decisions will be based on more comprehensive data, while at the same time this will optimize use of resources. The patient’s clinical picture should be the main factor that determines which method of IOP monitoring is most appropriate. A diurnal or ideally a 24-h IOP curve will positively impact the management of glaucoma patients who show functional/anatomical progression, despite an apparently acceptable IOP in the clinic. The potential impact of nocturnal IOP elevation remains poorly investigated. The ideal solution in the future is the development of non-invasive methods for obtaining continuous, Goldmann equivalent IOP data on all patients prior to key treatment decisions. Moreover, an important area of future research is to establish the precise relationship between 24-h IOP characteristics and glaucoma progression.
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW IOP is the only treatable risk factor contributing to glaucoma and most management and treatment of glaucoma is based on IOP. However, current IOP measurements are limited to office hours and control of glaucoma in many patients would benefit from the ability to monitor IOP diurnally so as not to miss abnormal pressures, which occur outside of office hours Consequently, to improve patient care, the ability to enable accurate and minimally disruptive diurnal IOP monitoring would improve caring for these patients. RECENT FINDINGS The studies we selected for this review can be divided into three categories: self-/home-tonometry, continuous invasive intraocular pressure measurements, and continuous noninvasive ocular measurements. SUMMARY The desire to obtain better insight in our patients' true diurnal IOP has led to the development of home-tonometers, in addition to extraocular and intraocular continuous pressure measurement devices. All of the devices have respective advantages and disadvantages, but none to date completely fulfills the goal of providing a true diurnal IOP profile.Video abstracthttp://links.lww.com/COOP/A27.
Collapse
|