1
|
Li R, Zheng S, Zhang Y, Zhang H, Du L, Cheng L, Li H, Zhang W, Du K, He W, Zhang W. Quantitative assessment of thenar to evaluate hand function after stroke by Bayes discriminant. BMC Musculoskelet Disord 2023; 24:682. [PMID: 37644487 PMCID: PMC10463400 DOI: 10.1186/s12891-023-06789-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 08/09/2023] [Indexed: 08/31/2023] Open
Abstract
BACKGROUND The incidence rate of stroke or cerebrovascular accidents ranks first in China. More than 85% of stroke patients have residual upper limb motor dysfunction, especially hand dysfunction. Normalizing the rehabilitation evaluation process and standard quantitative evaluation method is a complex and key point in rehabilitation therapy. The study aimed to establish a function model based on the Bayes discriminant by measuring the thenar stiffness with shear wave elastography (SWE) to quantitatively evaluate the hand motor function of hemiplegic patients after stroke. METHODS This study collected 60 patients diagnosed with hemiplegia after stroke from October 2021 to October 2022. Therapists used the Brunnstrom assessment (BA)scale to divide the patients into the stage. All the patients underwent the measurement of SWE examination of abductor pollicis brevis (APB), opponens pollicis (OP), flexor pollicis long tendon (FPLT), and flexor pollicis brevis (FPB) by two sonographers. The SWE change rate of four parts of the thenar area was calculated prospectively with the non-hemiplegic side as the reference, the function equation was established by the Bayes discriminant method, and the evaluation model was fitted according to the acquired training set data. Lastly, the model was verified by self-validation, cross-validation, and external data validation methods. The classification performance was evaluated regarding the area under the ROC curve (AUC), sensitivity, and specificity. RESULTS The median SWE values of the hemiplegic side of patients were lower than those of the non-hemiplegic side. According to the BA stage and SWER of APB, OP, FPLT, and FPB, our study established the Bayes discriminative model and validated it via self-validation and cross-validation methods. Then, the discriminant equation was used to validate 18 patients prospectively, the diagnostic coincidence rate was about 78.8%, and the misjudgment rate was approximately 21.2%. The AUC of the discriminant model for diagnosing BA stage I-VI was 0.928(95% CI: 0.839-1.0),0.858(95% CI: 0.748-0.969),1.0(95% CI: 1.0-1.0), 0.777(95% CI: 0.599-0.954),0.785(95% CI: 0.593-0.977) and 0.985(95% CI: 0.959-1.0), respectively. CONCLUSION This Bayes discriminant model built by measuring thenar stiffness was of diagnostic value and can provide an objective basis for evaluating clinical rehabilitation.
Collapse
Affiliation(s)
- Rui Li
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Shuai Zheng
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Yukang Zhang
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Hongxia Zhang
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Lijuan Du
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Linggang Cheng
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Hui Li
- Department of Ultrasound, Baoji City Hospital of Traditional Chinese Medicine, Baoji, China
| | - Wenkai Zhang
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Kai Du
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China
| | - Wen He
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China.
| | - Wei Zhang
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring Road West, Fengtai District, Beijing, 100070, China.
| |
Collapse
|
2
|
Roots J, Trajano GS, Fontanarosa D. Ultrasound elastography in the assessment of post-stroke muscle stiffness: a systematic review. Insights Imaging 2022; 13:67. [PMID: 35380302 PMCID: PMC8982789 DOI: 10.1186/s13244-022-01191-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 02/10/2022] [Indexed: 12/31/2022] Open
Abstract
Background Post-stroke muscle stiffness is a major challenge in the rehabilitation of stroke survivors, with no gold standard in clinical assessment. Muscle stiffness is typically evaluated by the Modified Ashworth Scale or the Tardieu Scale; however, these can have low reliability and sensitivity. Ultrasound elastography is an advanced imaging technology that can quantitatively measure the stiffness of a tissue and has been shown to have good construct validity when compared to clinically assessed muscle stiffness and functional motor recovery. Objective The purpose of this article is to systematically review the literature regarding the change in muscle stiffness as measured by ultrasound elastography in stroke survivors. Methods Scopus, PubMed, Embase, CINAHL, MEDLINE and Cochrane Library were searched for relevant studies that assessed the change in stiffness of post-stroke muscle stiffness measured by ultrasound elastography following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Results In total, 29 articles were identified, using either strain elastography and shear wave elastography to measure the stiffness of muscles in stroke survivors, most frequently in the biceps and medial gastrocnemius muscles. The stiffness was typically higher in the paretic compared to the non-paretic or healthy control. Other variations that increased the stiffness include increasing the joint angle and introducing a passive stretch or muscle activation. The paretic muscle has also been assessed pre- and post-treatment demonstrating a decrease in stiffness. Conclusion Ultrasound elastography is a promising imaging technology for determining the muscle stiffness in stroke survivors with need for a standardized imaging protocol.
Collapse
Affiliation(s)
- Jacqueline Roots
- School of Clinical Sciences, Queensland University of Technology, Gardens Point Campus, 2 George St, Brisbane, QLD, 4000, Australia.,Centre for Biomedical Technologies (CBT), Queensland University of Technology, 2 George St, Brisbane, QLD, 4000, Australia
| | - Gabriel S Trajano
- School of Exercise and Nutrition Sciences, Queensland University of Technology, Gardens Point Campus, 2 George St, Brisbane, QLD, 4000, Australia
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Gardens Point Campus, 2 George St, Brisbane, QLD, 4000, Australia. .,Centre for Biomedical Technologies (CBT), Queensland University of Technology, 2 George St, Brisbane, QLD, 4000, Australia.
| |
Collapse
|
3
|
Miller T, Ying M, Sau Lan Tsang C, Huang M, Pang MYC. Reliability and Validity of Ultrasound Elastography for Evaluating Muscle Stiffness in Neurological Populations: A Systematic Review and Meta-Analysis. Phys Ther 2021; 101:5928445. [PMID: 33508855 DOI: 10.1093/ptj/pzaa188] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 06/04/2020] [Accepted: 09/10/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVE Ultrasound elastography is an emerging diagnostic technology used to investigate the biomechanical properties of the musculoskeletal system. The purpose of this study was to systematically review the psychometric properties of ultrasound elastography techniques for evaluating muscle stiffness in people with neurological conditions. METHODS A systematic search of MEDLINE, EMBASE, CINAHL, and Cochrane Library databases was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Using software, reviewers independently screened citations for inclusion. Peer-reviewed studies that evaluated in vivo muscle stiffness in people with neurological conditions and reported relevant psychometric properties were considered for inclusion. Twenty-one articles were included for final review. Data relevant to measurement technique, site, and neurological condition were extracted. The Consensus-Based Standards for the Selection of Health Measurement Instruments checklist was used to rate the methodological quality of included studies. The level of evidence for specific measurement outcomes was determined using a best-evidence synthesis approach. RESULTS Reliability varied across populations, ultrasound systems, and assessment conditions (ie, joint/body positions, active/passive muscle conditions, probe orientation), with most studies indicating moderate to good reliability (ICC = 0.5-0.9, n = 13). Meta-analysis results showed a good overall correlation across studies (r = 0.78, 95% confidence interval = 0.64-0.86), with no between-group difference based on population (Q1 = 0.00). Convergent validity was demonstrated by strong correlations between stiffness values and measures of spasticity (n = 5), functional motor recovery or impairment (n = 5), and grayscale or color histogram pixel intensities (n = 3). Discriminant or known-groups validity was also established for multiple studies and indicated either significant between-group differences in stiffness values (n = 12) or within-group differences between more and less affected limbs (n = 6). Responsiveness was observed in all intervention studies reporting posttreatment stiffness changes (n = 6). CONCLUSIONS Overall, ultrasound elastography techniques showed moderate reliability in evaluating in vivo muscle stiffness, good convergent validity with relevant clinical assessments, and good divergent validity in discriminating tissue changes within and between groups. IMPACT Ultrasound elastography has clinical utility in assessing muscle stiffness, monitoring its temporal changes, and measuring the response to intervention in people with neurological conditions.
Collapse
Affiliation(s)
- Tiev Miller
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| | - Michael Ying
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, S.A.R
| | - Charlotte Sau Lan Tsang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| | - Meizhen Huang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| | - Marco Y C Pang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| |
Collapse
|
4
|
Rasool G, Wang AB, Rymer WZ, Lee SSM. Shear Waves Reveal Viscoelastic Changes in Skeletal Muscles After Hemispheric Stroke. IEEE Trans Neural Syst Rehabil Eng 2019; 26:2006-2014. [PMID: 30334740 DOI: 10.1109/tnsre.2018.2870155] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We investigated alterations in material properties such as elasticity and viscoelasticity of stroke-affected muscles using ultrasound induced shear waves and mechanical models. We used acoustic radiation force to generate shear waves along fascicles of biceps muscles and measured their propagation velocity. The shear wave data were collected in muscles of 13 hemiplegic stroke survivors under passive conditions at 90°, 120°, and 150° elbow flexion angles. In a viscoelastic medium, as opposed to a purely elastic medium, the shear wave propagation velocity depends on the frequency content of the induced wave. Therefore, in addition to the shear wave group velocity (GpV), we also estimated a frequency-dependent phase velocity (PhV). We found significantly higher GpVs and PhVs in stroke-affected muscles ( ). The velocity data were used to estimate shear elasticity and viscosity using an elastic and viscoelastic material models. A pure elastic model showed increased shear elasticity in stroke-affected muscles ( ). The Voigt model estimates of viscoelastic properties were also significantly different between the stroke-impaired and non-impaired muscles. We observed significantly larger model-estimated viscosity values on the stroke-affected side at elbow flexion angles of 120° and 150°. Furthermore, the creep behavior (tissue strain resulting from the application of sudden constant stress) of the model was also different between muscles of the paretic and non-paretic side. We speculate that these changes are associated with the structural disruption of muscles after stroke and may potentially affect force generation from muscle fibers as well as transmission of force to tendons.
Collapse
|
5
|
Saadat F, Son J, Rymer WZ, Lee SSM. Frequency Dependence of Shear Wave Velocity in Stroke-Affected Muscles During Isometric Contraction- Preliminary Data .. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:2292-2295. [PMID: 30440864 DOI: 10.1109/embc.2018.8512857] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In addition to changes in the central nervous system, many changes can occur in the composition and structure of skeletal muscles after a hemispheric stroke. The mechanical behavior of skeletal muscles is linked to the density and structural arrangement of key constituents. Yet, little is known about changes in post-stroke muscle mechanical properties such as viscoelasticity. The aim of this study was to explore the frequency-dependent changes in shear wave (SW) velocity as a potentially informative feature accompanying changes in muscle viscoelastic properties under passive and active conditions in hemiplegic stroke. We used the ultrasound SuperSonic Imaging technique to induce and measure SW propagation in the biceps brachii muscle for both the paretic and contralateral limbs in three hemiplegic stroke survivors during passive and submaximal voluntary muscle contractions. We found that for all subjects, the muscles on both the paretic and non-paretic sides demonstrated large dispersion (i.e., a change in SW phase velocities as a function of frequency within each contraction level) under both passive and active conditions, although muscles on the paretic side displayed larger dispersion. In addition, for a range of frequencies from 108-756 Hz, the SW phase velocity was higher in active nonparetic muscles compared to those of paretic side with an increase of 42% at 756 Hz. This is in contrast with the muscle response under passive condition where the SW phase velocity exhibited a 97 % increase at 765Hz on the paretic side compared to the non-paretic side. These results suggest the mechanical properties are altered for stroke-affected muscles, which may be a result of changes in the muscle extracellular matrix composition. Further, this study provides evidence that there are changes in tissue mechanical properties and that may consequently influence muscle function.
Collapse
|
6
|
Rubiano A, Delitto D, Han S, Gerber M, Galitz C, Trevino J, Thomas RM, Hughes SJ, Simmons CS. Viscoelastic properties of human pancreatic tumors and in vitro constructs to mimic mechanical properties. Acta Biomater 2018; 67:331-340. [PMID: 29191507 PMCID: PMC5797706 DOI: 10.1016/j.actbio.2017.11.037] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 11/08/2017] [Accepted: 11/14/2017] [Indexed: 01/18/2023]
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is almost universally fatal, in large part due to a protective fibrotic barrier generated by tumor-associated stromal (TAS) cells. This barrier is thought to promote cancer cell survival and confounds attempts to develop effective therapies. We present a 3D in vitro system that replicates the mechanical properties of the PDAC microenvironment, representing an invaluable tool for understanding the biology of the disease. Mesoscale indentation quantified viscoelastic metrics of resected malignant tumors, inflamed chronic pancreatitis regions, and histologically normal tissue. Both pancreatitis (2.15 ± 0.41 kPa, Mean ± SD) and tumors (5.46 ± 3.18 kPa) exhibit higher Steady-State Modulus (SSM) than normal tissue (1.06 ± 0.25 kPa; p < .005). The average viscosity of pancreatitis samples (63.2 ± 26.7 kPa·s) is significantly lower than that of both normal tissue (252 ± 134 kPa·s) and tumors (349 ± 222 kPa·s; p < .005). To mimic this remodeling behavior, PDAC and TAS cells were isolated from human PDAC tumors. Conditioned medium from PDAC cells was used to culture TAS-embedded collagen hydrogels. After 7 days, TAS-embedded gels in control medium reached SSM (1.45 ± 0.12 kPa) near normal pancreas, while gels maintained with conditioned medium achieved higher SSM (3.38 ± 0.146 kPa) consistent with tumors. Taken together, we have demonstrated an in vitro system that recapitulates in vivo stiffening of PDAC tumors. In addition, our quantification of viscoelastic properties suggests that elastography algorithms incorporating viscosity may be able to more accurately distinguish between pancreatic cancer and pancreatitis. STATEMENT OF SIGNIFICANCE Understanding tumor-stroma crosstalk in pancreatic ductal adenocarcinoma (PDAC) is challenged by a lack of stroma-mimicking model systems. To design appropriate models, pancreatic tissue must be characterized with a method capable of evaluating in vitro models as well. Our indentation-based characterization tool quantified the distinct viscoelastic signatures of inflamed resections from pancreatitis, tumors from PDAC, and otherwise normal tissue to inform development of mechanically appropriate engineered tissues and scaffolds. We also made progress toward a 3D in vitro system that recapitulates mechanical properties of tumors. Our in vitro model of stromal cells in collagen and complementary characterization system can be used to investigate mechanisms of cancer-stroma crosstalk in PDAC and to propose and test innovative therapies.
Collapse
Affiliation(s)
- Andres Rubiano
- Department of Mechanical and Aerospace Engineering, Herbert Wertheim College of Engineering, University of Florida, United States
| | - Daniel Delitto
- Department of Surgery, College of Medicine, University of Florida, United States
| | - Song Han
- Department of Surgery, College of Medicine, University of Florida, United States
| | - Michael Gerber
- Department of Surgery, College of Medicine, University of Florida, United States
| | - Carly Galitz
- Department of Mathematics, College of Liberal Arts and Sciences, University of Florida, United States
| | - Jose Trevino
- Department of Surgery, College of Medicine, University of Florida, United States
| | - Ryan M Thomas
- Department of Surgery, College of Medicine, University of Florida, United States
| | - Steven J Hughes
- Department of Surgery, College of Medicine, University of Florida, United States
| | - Chelsey S Simmons
- Department of Mechanical and Aerospace Engineering, Herbert Wertheim College of Engineering, University of Florida, United States; J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, United States.
| |
Collapse
|
7
|
Rasool G, Afsharipour B, Suresh NL, Rymer WZ. Spatial Analysis of Multichannel Surface EMG in Hemiplegic Stroke. IEEE Trans Neural Syst Rehabil Eng 2017; 25:1802-1811. [PMID: 28320672 DOI: 10.1109/tnsre.2017.2682298] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We investigated spatial activation patterns of upper extremity muscles during isometric force generation in both intact persons and in hemispheric stroke survivors. We used a 128-channel surface electromyogram (EMG) grid to record the electrical activity of biceps brachii muscles during these contractions. EMG data were processed to develop 2-D root mean square (RMS) maps of muscle activity. Our objective was to determine whether motor impairments following stroke were associated with changes in the muscle activity maps and in the spatial distribution of muscular activation. We found that, for a given subject, spatial patterns in muscle activity maps were consistent across all measured contraction levels differing only the RMS EMG. However, the maps from opposite arms (stroke-affected versus non-affected) of stroke survivors were significantly different from each other, especially when compared with the differences observed intact participants. Our analyses revealed that chronic stroke altered the size and location of the active region in these maps. The former is potentially related to disruption of fiber and tissue structure, possibly linked to factors such as extracellular fat accumulation, connective tissue infiltration, muscle fiber atrophy, fiber shortening, and fiber loss. Changes in spatial patterns in muscle activity maps may also be linked to a shift in the location of the innervation zone or the endplate region of muscles. Furthermore, the textural analysis of EMG activity maps showed a larger pixel-to-pixel variability in stroke-affected muscles. Alterations in the muscle activity maps were also related to functional impairment (estimated using Fugl-Meyer score) and to the degree of spasticity (estimated using the modified Ashworth scale). Overall, our investigation revealed that the muscle architecture and morphology were significantly altered in the chronic stroke.
Collapse
|