Hayashida Y, Kameda S, Umehira Y, Ishikawa S, Yagi T. Multichannel stimulation module as a tool for animal studies on cortical neural prostheses. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:927581. [PMID: 36176924 PMCID: PMC9513350 DOI: 10.3389/fmedt.2022.927581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 08/08/2022] [Indexed: 11/13/2022] Open
Abstract
Intracortical microstimulation to the visual cortex is thought to be a feasible technique for inducing localized phosphenes in patients with acquired blindness, and thereby for visual prosthesis. In order to design effective stimuli for the prosthesis, it is important to elucidate relationships between the spatio-temporal patterns of stimuli and the resulting neural responses and phosphenes through pre-clinical animal studies. However, the physiological basis of effective spatial patterns of the stimuli for the prosthesis has been little investigated in the literature, at least partly because that the previously developed multi-channel stimulation systems were designed specifically for the clinical use. In the present, a 64-channel stimulation module was developed as a scalable tool for animal experiments. The operations of the module were verified by not only dry-bench tests but also physiological animal experiments in vivo. The results demonstrated its usefulness for examining the stimulus-response relationships in a quantitative manner, and for inducing the multi-site neural excitations with a multi-electrode array. In addition, this stimulation module could be used to generate spatially patterned stimuli with up to 4,096 channels in a dynamic way, in which the stimulus patterns can be updated at a certain frame rate in accordance with the incoming visual scene. The present study demonstrated that our stimulation module is applicable to the physiological and other future studies in animals on the cortical prostheses.
Collapse
Affiliation(s)
- Yuki Hayashida
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
- Department of Information Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
| | - Seiji Kameda
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
| | - Yuichi Umehira
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
| | - Shinnosuke Ishikawa
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
| | - Tetsuya Yagi
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
- Department of Electrical and Electronic Engineering, School of Engineering, Fukui University of Technology, Fukui, Japan
| |
Collapse
|
2
|
MCU-less biphasic electrical stimulation circuit for miniaturized neuromodulator. Biomed Eng Lett 2022; 12:285-293. [DOI: 10.1007/s13534-022-00239-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 06/10/2022] [Accepted: 06/21/2022] [Indexed: 11/26/2022] Open
|
3
|
Kuo PH, Wong OY, Tzeng CK, Wu PW, Chiao CC, Chen PH, Chen PC, Tsai YC, Chu FL, Ohta J, Tokuda T, Noda T, Wu CY. Improved Charge Pump Design and Ex Vivo Experimental Validation of CMOS 256-Pixel Photovoltaic-Powered Subretinal Prosthetic Chip. IEEE Trans Biomed Eng 2019; 67:1490-1504. [PMID: 31494538 DOI: 10.1109/tbme.2019.2938807] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
An improved design of CMOS 256-pixel photovoltaic-powered implantable chip for subretinal prostheses is presented. In the proposed subretinal chip, a high-efficiency fully-integrated 4× charge pump is designed and integrated with on-chip photovoltaic (PV) cells and a 256-pixel array with active pixel sensors (APS) for image light sensing, biphasic constant current stimulators, and electrodes. Thus the PV voltage generated by infrared (IR) light can be boosted to above 1V so that the charge injection is increased. The proposed chip adopts the 32-phase divisional power supply scheme (DPSS) to reduce the required supply current and thus the required area of the PV cells. The proposed chip is designed and fabricated in 180-nm CMOS image sensor (CIS) technology and post-processed with biocompatible IrOx electrodes and silicone packaging. From the electrical measurement results, the measured stimulation frequency is 28.3 Hz under the equivalent electrode impedance load. The measured maximum output stimulation current is 7.1 μA and the amount of injected charges per pixel is 7.36 nC under image light intensity of 3200 lux and IR light intensity of 100 mW/cm2. The function of the proposed chip has been further validated successfully with the ex vivo experimental results by recording the electrophysiological responses of retinal ganglion cells (RGCs) of retinas from retinal degeneration (rd1) mice with a multi-electrode array (MEA). The measured average threshold injected charge is about 3.97 nC which is consistent with that obtained from the patch clamp recording on retinas from wild type (C57BL/6) mice with a single electrode pair.
Collapse
|
4
|
Lancashire HT, Jiang D, Demosthenous A, Donaldson N. An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:259-270. [PMID: 30624225 DOI: 10.1109/tbcas.2019.2891284] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This paper presents an active microchannel neural interface (MNI) using seven stacked application specific integrated circuits (ASICs). The approach provides a solution to the present problem of interconnect density in three-dimensional (3-D) MNIs. The 4 mm2 ASIC is implemented in 0.35 μm high-voltage CMOS technology. Each ASIC is the base for seven microchannels each with three electrodes in a pseudo-tripolar arrangement. Multiplexing allows stimulating or recording from any one of 49 channels, across seven ASICs. Connections to the ASICs are made with a five-line parallel bus. Current controlled biphasic stimulation from 5 to 500 μA has been demonstrated with switching between channels and ASICs. The high-voltage technology gives a compliance of 40 V for stimulation, appropriate for the high impedances within microchannels. High frequency biphasic stimulation, up to 40 kHz is achieved, suitable for reversible high frequency nerve blockades. Recording has been demonstrated with mV level signals; common-mode inputs are differentially distorted and limit the CMRR to 40 dB. The ASIC has been used in vitro in conjunction with an oversize (2 mm diameter) microchannel in phosphate buffered saline, demonstrating attenuation of interference from outside the microchannel and tripolar recording of signals from within the microchannel. By using five-lines for 49 active microchannels the device overcomes limitations when connecting many electrodes in a 3-D miniaturized nerve interface.
Collapse
|
5
|
Jiang D, Demosthenous A. A Multichannel High-Frequency Power-Isolated Neural Stimulator With Crosstalk Reduction. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:940-953. [PMID: 29993559 DOI: 10.1109/tbcas.2018.2832541] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In neuroprostheses applications requiring simultaneous stimulations on a multielectrode array, electric crosstalk, the spatial interaction between electric fields from various electrodes is a major limitation to the performance of multichannel stimulation. This paper presents a multichannel stimulator design that combines high-frequency current stimulation (using biphasic charge-balanced chopped pulse profile) with a switched-capacitor power isolation method. The approach minimizes crosstalk and is particularly suitable for fully integrated realization. A stimulator fabricated in a 0.6 μm CMOS high-voltage technology is presented. It is used to implement a multichannel, high-frequency, power-isolated stimulator. Crosstalk reduction is demonstrated with electrodes in physiological media while the efficacy of the high-frequency stimulator chip is proven in vivo. The stimulator provides fully independent operation on multiple channels and full flexibility in the design of neural modulation protocols.
Collapse
|
6
|
Design of a Compact Wireless Multi-Channel High Area-Efficient Stimulator with Arbitrary Channel Configuration. MICROMACHINES 2017; 9:mi9010006. [PMID: 30393283 PMCID: PMC6187733 DOI: 10.3390/mi9010006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 12/15/2017] [Accepted: 12/18/2017] [Indexed: 11/23/2022]
Abstract
This paper presents the design of a wireless, implantable, multi-channel, programmable stimulator with arbitrary channel combination. A novel channel management module using a switch array is presented, enabling arbitrary channel configuration with a silicon area reduction of 81%. The chip was fabricated in a 0.18-μm Taiwan semiconductor manufacturing company (TSMC) high voltage (HV) complementary metal–oxide semiconductor (CMOS) technology. A stimulator system was realized using the proposed integrated circuit (IC). A wireless communication link was established between a specified Android-based graphical user interface (GUI) and the proposed device for control of the stimulation pattern and wireless battery charging. The size of the entire system occupies a volume of only 14 mm × 14 mm × 4 mm (without the battery). Experimental results demonstrated a successful independent configuration between different channels, as well as an arbitrary channel combination, as expected.
Collapse
|
7
|
Luo Z, Ker MD. A High-Voltage-Tolerant and Precise Charge-Balanced Neuro-Stimulator in Low Voltage CMOS Process. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:1087-1099. [PMID: 27046880 DOI: 10.1109/tbcas.2015.2512443] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper presents a 4 × VDD neuro-stimulator in a 0.18- μm 1.8 V/3.3 V CMOS process. The self-adaption bias technique and stacked MOS configuration are used to prevent transistors from the electrical overstress and gate-oxide reliability issue. A high-voltage-tolerant level shifter with power-on protection is used to drive the neuro-stimulator The reliability measurement of up to 100 million periodic cycles with 3000- μA biphasic stimulations in 12-V power supply has verified that the proposed neuro-stimulator is robust. Precise charge balance is achieved by using a novel current memory cell with the dual calibration loops and leakage current compensation. The charge mismatch is down to 0.25% over all the stimulus current ranges (200-300 μA) The residual average dc current is less than 6.6 nA after shorting operation.
Collapse
|
8
|
Töreyin H, Bhatti PT. A Low-Power ASIC Signal Processor for a Vestibular Prosthesis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:768-78. [PMID: 26800546 PMCID: PMC5753592 DOI: 10.1109/tbcas.2015.2495341] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A low-power ASIC signal processor for a vestibular prosthesis (VP) is reported. Fabricated with TI 0.35 μm CMOS technology and designed to interface with implanted inertial sensors, the digitally assisted analog signal processor operates extensively in the CMOS subthreshold region. During its operation the ASIC encodes head motion signals captured by the inertial sensors as electrical pulses ultimately targeted for in-vivo stimulation of vestibular nerve fibers. To achieve this, the ASIC implements a coordinate system transformation to correct for misalignment between natural sensors and implanted inertial sensors. It also mimics the frequency response characteristics and frequency encoding mappings of angular and linear head motions observed at the peripheral sense organs, semicircular canals and otolith. Overall the design occupies an area of 6.22 mm (2) and consumes 1.24 mW when supplied with ± 1.6 V.
Collapse
|
9
|
Hageman KN, Kalayjian ZK, Tejada F, Chiang B, Rahman MA, Fridman GY, Dai C, Pouliquen PO, Georgiou J, Della Santina CC, Andreou AG. A CMOS Neural Interface for a Multichannel Vestibular Prosthesis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:269-79. [PMID: 25974945 PMCID: PMC4641830 DOI: 10.1109/tbcas.2015.2409797] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We present a high-voltage CMOS neural-interface chip for a multichannel vestibular prosthesis (MVP) that measures head motion and modulates vestibular nerve activity to restore vision- and posture-stabilizing reflexes. This application specific integrated circuit neural interface (ASIC-NI) chip was designed to work with a commercially available microcontroller, which controls the ASIC-NI via a fast parallel interface to deliver biphasic stimulation pulses with 9-bit programmable current amplitude via 16 stimulation channels. The chip was fabricated in the ONSemi C5 0.5 micron, high-voltage CMOS process and can accommodate compliance voltages up to 12 V, stimulating vestibular nerve branches using biphasic current pulses up to 1.45±0.06 mA with durations as short as 10 μs/phase. The ASIC-NI includes a dedicated digital-to-analog converter for each channel, enabling it to perform complex multipolar stimulation. The ASIC-NI replaces discrete components that cover nearly half of the 2nd generation MVP (MVP2) printed circuit board, reducing the MVP system size by 48% and power consumption by 17%. Physiological tests of the ASIC-based MVP system (MVP2A) in a rhesus monkey produced reflexive eye movement responses to prosthetic stimulation similar to those observed when using the MVP2. Sinusoidal modulation of stimulus pulse rate from 68-130 pulses per second at frequencies from 0.1 to 5 Hz elicited appropriately-directed slow phase eye velocities ranging in amplitude from 1.9-16.7 °/s for the MVP2 and 2.0-14.2 °/s for the MVP2A. The eye velocities evoked by MVP2 and MVP2A showed no significant difference ( t-test, p=0.34), suggesting that the MVP2A achieves performance at least as good as the larger MVP2.
Collapse
Affiliation(s)
- Kristin N. Hageman
- Vestibular NeuroEngineering Lab (affiliated with the Departments of Biomedical Engineering and Otolaryngology Head and Neck Surgery), Johns Hopkins School of Medicine, Baltimore, MD 21205 USA
| | - Zaven K. Kalayjian
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218 USA
| | - Francisco Tejada
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218 USA
| | - Bryce Chiang
- Vestibular NeuroEngineering Lab (affiliated with the Departments of Biomedical Engineering and Otolaryngology Head and Neck Surgery), Johns Hopkins School of Medicine, Baltimore, MD 21205 USA
| | - Mehdi A. Rahman
- Vestibular NeuroEngineering Lab (affiliated with the Departments of Biomedical Engineering and Otolaryngology Head and Neck Surgery), Johns Hopkins School of Medicine, Baltimore, MD 21205 USA
| | - Gene Y. Fridman
- Vestibular NeuroEngineering Lab (affiliated with the Departments of Biomedical Engineering and Otolaryngology Head and Neck Surgery), Johns Hopkins School of Medicine, Baltimore, MD 21205 USA
| | - Chenkai Dai
- Vestibular NeuroEngineering Lab (affiliated with the Departments of Biomedical Engineering and Otolaryngology Head and Neck Surgery), Johns Hopkins School of Medicine, Baltimore, MD 21205 USA
| | - Philippe O. Pouliquen
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218 USA
| | - Julio Georgiou
- Department of Electrical and Computer Engineering, University of Cyprus, 1678 Nicosa, Cyprus
| | - Charles C. Della Santina
- Vestibular NeuroEngineering Lab (affiliated with the Departments of Biomedical Engineering and Otolaryngology Head and Neck Surgery), Johns Hopkins School of Medicine, Baltimore, MD 21205 USA
| | - Andreas G. Andreou
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218 USA
| |
Collapse
|
10
|
Unguez G, Duran C, Valles-Rosales D, Harris M, Salazar E, McDowell M, Tang W. 3D-printed wearable backpack stimulator for chronic in vivo aquatic stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:2147-50. [PMID: 26736714 DOI: 10.1109/embc.2015.7318814] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The neural mechanisms underlying changes in gene expression in the interconversion between skeletal muscle and the non-contractile electrogenic cells of the electric organ in electric fishes require several days to be manifested. It is extremely challenging to study these non-immediate forms of plasticity in reduced preparations in cell culture due to the time requirements. To address this experimental obstacle we developed a 3D-printed wearable backpack that allows chronic electrical stimulation of aquatic teleost fish. The backpack holds a biphasic simulator using a full H-bridge driver structure. Stimulation amplitude is adjusted with a current source controlled by a micro potentiometer whereas the stimulation waveform is reconfigurable through a micro-controller. A 3.7 V Lithium Ion Polymer battery powers the entire circuit. This backpack system will allow underwater chronic stimulation experiments aimed to study the role that neuronal input exerts on cell phenotypes in a vertebrate species with high tissue regeneration and cell trans-differentiation capabilities.
Collapse
|
11
|
Becerra-Fajardo L, Ivorra A. In Vivo Demonstration of Addressable Microstimulators Powered by Rectification of Epidermically Applied Currents for Miniaturized Neuroprostheses. PLoS One 2015; 10:e0131666. [PMID: 26147771 PMCID: PMC4493086 DOI: 10.1371/journal.pone.0131666] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 06/05/2015] [Indexed: 11/18/2022] Open
Abstract
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters < 0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to decode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we numerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible.
Collapse
Affiliation(s)
- Laura Becerra-Fajardo
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain
- * E-mail:
| | - Antoni Ivorra
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain
| |
Collapse
|
12
|
Shulyzki R, Abdelhalim K, Bagheri A, Salam MT, Florez CM, Velazquez JLP, Carlen PL, Genov R. 320-channel active probe for high-resolution neuromonitoring and responsive neurostimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:34-49. [PMID: 25486647 DOI: 10.1109/tbcas.2014.2312552] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We present a 320-channel active probe for high-spatial-resolution neuromonitoring and responsive neurostimulation. The probe comprises an integrated circuit (IC) cell array bonded to the back side of a pitch-matched microelectrode array. The IC enables up to 256-site neural recording and 64-site neural stimulation at the spatial resolution of 400 μ m and 200 μ m, respectively. It is suitable for direct integration with electrode arrays with the shank pitch of integer multiples of 200 μm. In the presented configuration, the IC is bonded with a 8 × 8 400 μ m-pitch Utah electrode array (UEA) and up to additional 192 recording channels are used for peripheral neuromonitoring. The 0.35 μ m CMOS circuit array has a total die size of 3.5 mm × 3.65 mm. Each stimulator channel employs a current memory for simultaneous multi-site neurostimulation, outputs 20 μA-250 μA square or arbitrary waveform current, occupies 0.02 mm (2), and dissipates 2.76 μ W quiescent power. Each fully differential recording channel has two stages of amplification and filtering and an 8-bit single-slope ADC, occupies 0.035 mm (2) , and consumes 51.9 μ W. The neural probe has been experimentally validated in epileptic seizure propagation studies in a mouse hippocampal slice in vitro and in responsive neurostimulation for seizure suppression in an acute epilepsy rat model in vivo .
Collapse
|
13
|
Jiang D, Cirmirakis D, Demosthenous A. A vestibular prosthesis with highly-isolated parallel multichannel stimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:124-137. [PMID: 25073175 DOI: 10.1109/tbcas.2014.2323310] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This paper presents an implantable vestibular stimulation system capable of providing high flexibility independent parallel stimulation to the semicircular canals in the inner ear for restoring three-dimensional sensation of head movements. To minimize channel interaction during parallel stimulation, the system is implemented with a power isolation method for crosstalk reduction. Experimental results demonstrate that, with this method, electrodes for different stimulation channels located in close proximity ( mm) can deliver current pulses simultaneously with minimum inter-channel crosstalk. The design features a memory-based scheme that manages stimulation to the three canals in parallel. A vestibular evoked potential (VEP) recording unit is included for closed-loop adaptive stimulation control. The main components of the prototype vestibular prosthesis are three ASICs, all implemented in a 0.6- μm high-voltage CMOS technology. The measured performance was verified using vestibular electrodes in vitro.
Collapse
|
14
|
Becerra-Fajardo L, Ivorra A. Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:3973-6. [PMID: 25570862 DOI: 10.1109/embc.2014.6944494] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Electrical stimulation has been explored to restore the capabilities of the nervous system in paralysis patients. This area of research and of clinical practice, known as Functional Electrical Stimulation, would greatly benefit from further miniaturization of implantable stimulators. To that end, we recently proposed and demonstrated an innovative electrical stimulation method in which implanted microstimulators operate as rectifiers of bursts of innocuous high frequency current supplied by skin electrodes, thus generating low frequency currents capable of stimulating excitable tissues. A diode could suffice in some applications but, in order to broaden the method's clinical applicability, we envision rectifiers with advanced capabilities such as current control and addressability. We plan flexible thread-like implants (diameters < 300 μm) containing ASICs. As an intermediate stage, we are developing macroscopic implants (diameters ~ 2 mm) made of off-the-shelf components. Here we present a circuit which responds to commands modulated within the high frequency bursts and which is able to deliver charge-balanced currents. We show that a number of these circuits can perform independent stimulation of segments of an anesthetized earthworm following commands from a computer.
Collapse
|
15
|
Corradi F, Zambrano D, Raglianti M, Passetti G, Laschi C, Indiveri G. Towards a neuromorphic vestibular system. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2014; 8:669-680. [PMID: 25314706 DOI: 10.1109/tbcas.2014.2358493] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The vestibular system plays a crucial role in the sense of balance and spatial orientation in mammals. It is a sensory system that detects both rotational and translational motion of the head, via its semicircular canals and otoliths respectively. In this work, we propose a real-time hardware model of an artificial vestibular system, implemented using a custom neuromorphic Very Large Scale Integration (VLSI) multi-neuron chip interfaced to a commercial Inertial Measurement Unit (IMU). The artificial vestibular system is realized with spiking neurons that reproduce the responses of biological hair cells present in the real semicircular canals and otholitic organs. We demonstrate the real-time performance of the hybrid analog-digital system and characterize its response properties, presenting measurements of a successful encoding of angular velocities as well as linear accelerations. As an application, we realized a novel implementation of a recurrent integrator network capable of keeping track of the current angular position. The experimental results provided validate the hardware implementation via comparisons with a detailed computational neuroscience model. In addition to being an ideal tool for developing bio-inspired robotic technologies, this work provides a basis for developing a complete low-power neuromorphic vestibular system which integrates the hardware model of the neural signal processing pathway described with custom bio-mimetic gyroscopic sensors, exploiting neuromorphic principles in both mechanical and electronic aspects.
Collapse
|
16
|
Nguyen TAK, Ranieri M, DiGiovanna J, Peter O, Genovese V, Perez Fornos A, Micera S. A real-time research platform to study vestibular implants with gyroscopic inputs in vestibular deficient subjects. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2014; 8:474-484. [PMID: 25073124 DOI: 10.1109/tbcas.2013.2290089] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Researchers have succeeded in partly restoring damaged vestibular functionality in several animal models. Recently, acute interventions have also been demonstrated in human patients. Our previous work on a vestibular implant for humans used predefined stimulation patterns; here we present a research tool that facilitates motion-modulated stimulation. This requires a system that can process gyroscope measurements and send stimulation parameters to a hybrid vestibular-cochlear implant in real-time. To match natural vestibular latencies, the time from sensor input to stimulation output should not exceed 6.5 ms. We describe a system based on National Instrument's CompactRIO platform that can meet this requirement and also offers floating point precision for advanced transfer functions. It is designed for acute clinical interventions, and is sufficiently powerful and flexible to serve as a development platform for evaluating prosthetic control strategies. Amplitude and pulse frequency modulation to predetermined functions or sensor inputs have been validated. The system has been connected to human patients, who each have received a modified MED-EL cochlear implant for vestibular stimulation, and patient tests are ongoing.
Collapse
|
17
|
Andreou CM, Pahitas Y, Georgiou J. Bio-inspired micro-fluidic angular-rate sensor for vestibular prostheses. SENSORS 2014; 14:13173-85. [PMID: 25054631 PMCID: PMC4168436 DOI: 10.3390/s140713173] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 07/01/2014] [Accepted: 07/09/2014] [Indexed: 11/16/2022]
Abstract
This paper presents an alternative approach for angular-rate sensing based on the way that the natural vestibular semicircular canals operate, whereby the inertial mass of a fluid is used to deform a sensing structure upon rotation. The presented gyro has been fabricated in a commercially available MEMS process, which allows for microfluidic channels to be implemented in etched glass layers, which sandwich a bulk-micromachined silicon substrate, containing the sensing structures. Measured results obtained from a proof-of-concept device indicate an angular rate sensitivity of less than 1 °/s, which is similar to that of the natural vestibular system. By avoiding the use of a continually-excited vibrating mass, as is practiced in today's state-of-the-art gyroscopes, an ultra-low power consumption of 300 μW is obtained, thus making it suitable for implantation.
Collapse
Affiliation(s)
- Charalambos M Andreou
- Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
| | - Yiannis Pahitas
- Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
| | - Julius Georgiou
- Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
| |
Collapse
|
18
|
Töreyin H, Bhatti P. A field-programmable analog array development platform for vestibular prosthesis signal processing. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:319-325. [PMID: 23853331 PMCID: PMC4349338 DOI: 10.1109/tbcas.2012.2216525] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report on a vestibular prosthesis signal processor realized using an experimental field programmable analog array (FPAA). Completing signal processing functions in the analog domain, the processor is designed to help replace a malfunctioning inner ear sensory organ, a semicircular canal. Relying on angular head motion detected by an inertial sensor, the signal processor maps angular velocity into meaningful control signals to drive a current stimulator. To demonstrate biphasic pulse control a 1 k Ω resistive load was placed across an H-bridge circuit. When connected to a 2.4 V supply, a biphasic current of 100 μA was maintained at stimulation frequencies from 50-350 Hz, pulsewidths from 25-400 μ sec, and interphase gaps ranging from 25-250 μsec.
Collapse
Affiliation(s)
- Hakan Töreyin
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0250, USA.
| | | |
Collapse
|
19
|
Nag S, Jia X, Thakor NV, Sharma D. Flexible charge balanced stimulator with 5.6 fC accuracy for 140 nC injections. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:266-275. [PMID: 23853326 DOI: 10.1109/tbcas.2012.2205574] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Electrical stimulations of neuronal structures must ensure net injected charges to be zero for biological safety and voltage compliance reasons. We present a novel architecture of general purpose biphasic constant current stimulator that exhibits less than 5.6 fC error while injecting 140 nC charges using 1.4 mA currents. The floating current sources and conveyor switch based system can operate in monopolar or bipolar modes. Anodic-first or cathodic-first pulses with optional inter-phase delays have been demonstrated with zero quiescent current requirements at the analog front-end. The architecture eliminates blocking capacitors, electrode shorting and complex feedbacks. Bench-top and in-vivo measurement results have been presented with emulated electrode impedances (resistor-capacitor network), Ag-AgCl electrodes in saline and in-vivo (acute) peripheral nerve stimulations in anesthetized rats.
Collapse
Affiliation(s)
- Sudip Nag
- Electrical Engineering Department, Indian Institute of Technology Bombay, IIT Powai, Mumbai, Maharashtra 400076, India.
| | | | | | | |
Collapse
|
20
|
Chiu HW, Chuang JM, Lu CC, Lin WT, Lin CW, Lin ML. In situ measurement of tissue impedance using an inductive coupling interface circuit. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:225-235. [PMID: 23853322 DOI: 10.1109/tbcas.2012.2199488] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this work, a method of an inductive coupling impedance measurement (ICIM) is proposed for measuring the nerve impedance of a dorsal root ganglion (DRG) under PRF stimulation. ICIM provides a contactless interface for measuring the reflected impedance by an impedance analyzer with a low excitation voltage of 7 mV. The paper develops a calibration procedure involving a 50-Ω reference resistor to calibrate the reflected resistance for measuring resistance of the nerve in the test. A de-embedding technique to build the equivalent transformer circuit model for the ICIM circuit is also presented. A batteryless PRF stimulator with ICIM circuit demonstrated good accuracy for the acute measurement of DRG impedance both in situ and in vivo. Besides, an in vivo animal experiment was conducted to show that the effectiveness of pulsed radiofrequency (PRF) stimulation in relieving pain gradually declined as the impedance of the stimulated nerve increased. The experiment also revealed that the excitation voltage for measuring impedance below 25 mV can prevent the excitation of a nonlinear response of DRG.
Collapse
Affiliation(s)
- Hung-Wei Chiu
- Department of Electronic Engineering and Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
| | | | | | | | | | | |
Collapse
|
21
|
Chiu HW, Lu CC, Chuang JM, Lin WT, Lin CW, Kao MC, Lin ML. A dual-mode highly efficient class-E stimulator controlled by a low-Q class-E power amplifier through duty cycle. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:243-255. [PMID: 23853324 DOI: 10.1109/tbcas.2012.2205245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper presents the design flow of two high-efficiency class-E amplifiers for the implantable electrical stimulation system. The implantable stimulator is a high-Q class-E driver that delivers a sine-wave pulsed radiofrequency (PRF) stimulation, which was verified to have a superior efficacy in pain relief to a square wave. The proposed duty-cycle-controlled class-E PRF driver designed with a high-Q factor has two operational modes that are able to achieve 100% DC-AC conversion, and involves only one switched series inductor and an unchanged parallel capacitor. The measured output amplitude under low-voltage (LV) mode using a 22% duty cycle was 0.98 V with 91% efficiency, and under high-voltage (HV) mode using a 47% duty cycle was 2.95 V with 92% efficiency. These modes were inductively controlled by a duty-cycle detector, which can detect the duty-cycle modulated signal generated from the external complementary low-Q class-E power amplifier (PA). The design methodology of the low-Q inductive interface for a non-50% duty cycle is presented. The experimental results exhibits that the 1.5-V PA that consumes DC power of 14.21 mW was able to deliver a 2.9-V sine wave to a 500 Ω load. The optimal 60% drain efficiency of the system from the PA to the load was obtained at a 10-mm coupling distance.
Collapse
Affiliation(s)
- Hung-Wei Chiu
- Department of Electronic Engineering and Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
| | | | | | | | | | | | | |
Collapse
|
22
|
Chu JU, Song KI, Shon A, Han S, Lee SH, Kang JY, Hwang D, Suh JKF, Choi K, Youn I. Feedback control of electrode offset voltage during functional electrical stimulation. J Neurosci Methods 2013; 218:55-71. [PMID: 23685268 DOI: 10.1016/j.jneumeth.2013.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Revised: 05/09/2013] [Accepted: 05/09/2013] [Indexed: 10/26/2022]
Abstract
Control of the electrode offset voltage is an important issue related to the processes of functional electrical stimulation because excess charge accumulation over time damages both the tissue and the electrodes. This paper proposes a new feedback control scheme to regulate the electrode offset voltage to a predetermined reference value. The electrode offset voltage was continuously monitored using a sample-and-hold (S/H) circuit during stimulation and non-stimulation periods. The stimulation current was subsequently adjusted using a proportional-integral (PI) controller to minimise the error between the reference value and the electrode offset voltage. During the stimulation period, the electrode offset voltage was maintained through the S/H circuit, and the PI controller did not affect the amplitude of the stimulation current. In contrast, during the non-stimulation period, the electrode offset voltage was sampled through the S/H circuit and rapidly regulated through the PI controller. The experimental results obtained using a nerve cuff electrode showed that the electrode offset voltage was successfully controlled in terms of the performance specifications, such as the steady- and transient-state responses and the constraint of the controller output. Therefore, the proposed control scheme can potentially be used in various nerve stimulation devices and applications requiring control of the electrode offset voltage.
Collapse
Affiliation(s)
- Jun-Uk Chu
- Biomedical Research Institute, Korea Institute of Science and Technology, 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul 136-791, Republic of Korea
| | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Valentin NS, Hageman KN, Dai C, Della Santina CC, Fridman GY. Development of a multichannel vestibular prosthesis prototype by modification of a commercially available cochlear implant. IEEE Trans Neural Syst Rehabil Eng 2013; 21:830-9. [PMID: 23649285 DOI: 10.1109/tnsre.2013.2259261] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
No adequate treatment exists for individuals who remain disabled by bilateral loss of vestibular (inner ear inertial) sensation despite rehabilitation. We have restored vestibular reflexes using lab-built multichannel vestibular prostheses (MVPs) in animals, but translation to clinical practice may be best accomplished by modification of a commercially available cochlear implant (CI). In this interim report, we describe preliminary efforts toward that goal. We developed software and circuitry to sense head rotation and drive a CI's implanted stimulator (IS) to deliver up to 1 K pulses/s via nine electrodes implanted near vestibular nerve branches. Studies in two rhesus monkeys using the modified CI revealed in vivo performance similar to our existing dedicated MVPs. A key focus of our study was the head-worn unit (HWU), which magnetically couples across the scalp to the IS. The HWU must remain securely fixed to the skull to faithfully sense head motion and maintain continuous stimulation. We measured normal and shear force thresholds at which HWU-IS decoupling occurred as a function of scalp thickness and calculated pressure exerted on the scalp. The HWU remained attached for human scalp thicknesses from 3-7.8 mm for forces experienced during routine daily activities, while pressure on the scalp remained below capillary perfusion pressure.
Collapse
|
24
|
Williams I, Constandinou TG. An energy-efficient, dynamic voltage scaling neural stimulator for a proprioceptive prosthesis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:129-139. [PMID: 23853295 DOI: 10.1109/tbcas.2013.2256906] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper presents an 8 channel energy-efficient neural stimulator for generating charge-balanced asymmetric pulses. Power consumption is reduced by implementing a fully-integrated DC-DC converter that uses a reconfigurable switched capacitor topology to provide 4 output voltages for Dynamic Voltage Scaling (DVS). DC conversion efficiencies of up to 82% are achieved using integrated capacitances of under 1 nF and the DVS approach offers power savings of up to 50% compared to the front end of a typical current controlled neural stimulator. A novel charge balancing method is implemented which has a low level of accuracy on a single pulse and a much higher accuracy over a series of pulses. The method used is robust to process and component variation and does not require any initial or ongoing calibration. Measured results indicate that the charge imbalance is typically between 0.05%-0.15% of charge injected for a series of pulses. Ex-vivo experiments demonstrate the viability in using this circuit for neural activation. The circuit has been implemented in a commercially-available 0.18 μm HV CMOS technology and occupies a core die area of approximately 2.8 mm(2) for an 8 channel implementation.
Collapse
Affiliation(s)
- Ian Williams
- Centre for Bio-Inspired Technology and the Department of Electrical and Electronic Engineering, Imperial College London, London SW7 2BT, UK.
| | | |
Collapse
|
25
|
Fridman GY, Della Santina CC. Progress toward development of a multichannel vestibular prosthesis for treatment of bilateral vestibular deficiency. Anat Rec (Hoboken) 2012; 295:2010-29. [PMID: 23044664 DOI: 10.1002/ar.22581] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Accepted: 07/24/2012] [Indexed: 12/11/2022]
Abstract
This article reviews vestibular pathology and the requirements and progress made in the design and construction of a vestibular prosthesis. Bilateral loss of vestibular sensation is disabling. When vestibular hair cells are injured by ototoxic medications or other insults to the labyrinth, the resulting loss of sensory input disrupts vestibulo-ocular reflexes (VORs) and vestibulo-spinal reflexes that normally stabilize the eyes and body. Affected individuals suffer poor vision during head movement, postural instability, chronic disequilibrium, and cognitive distraction. Although most individuals with residual sensation compensate for their loss over time, others fail to do so and have no adequate treatment options. A vestibular prosthesis analogous to cochlear implants but designed to modulate vestibular nerve activity during head movement should improve quality of life for these chronically dizzy individuals. We describe the impact of bilateral loss of vestibular sensation, animal studies supporting feasibility of prosthetic vestibular stimulation, the current status of multichannel vestibular sensory replacement prosthesis development, and challenges to successfully realizing this approach in clinical practice. In bilaterally vestibular-deficient rodents and rhesus monkeys, the Johns Hopkins multichannel vestibular prosthesis (MVP) partially restores the three-dimensional (3D) VOR for head rotations about any axis. Attempts at prosthetic vestibular stimulation of humans have not yet included the 3D eye movement assays necessary to accurately evaluate VOR alignment, but these initial forays have revealed responses that are otherwise comparable to observations in animals. Current efforts now focus on refining electrode design and surgical technique to enhance stimulus selectivity and preserve cochlear function, optimizing stimulus protocols to improve dynamic range and reduce excitation-inhibition asymmetry, and adapting laboratory MVP prototypes into devices appropriate for use in clinical trials.
Collapse
Affiliation(s)
- Gene Y Fridman
- Department of Otolaryngology-Head & Neck surgery, Johns Hopkins School of Medicine, Baltimore, Maryland 21205, USA.
| | | |
Collapse
|
26
|
Bhatti PT, McClain MA. Low-power sensing for vestibular prostheses. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:3131-4. [PMID: 22255003 DOI: 10.1109/iembs.2011.6090854] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper describes a novel sensing approach for reducing power requirements of implantable vestibular prostheses. A passive, microfabricated polymeric inertial sensor for detecting angular head rotations based on the biomechanics of the human semicircular canal is described. Angular head motion is coded by deflection of a highly compliant capacitor plate placed in parallel with a rigid reference electrode. This capacitance change serves to detect instantaneous angular velocity along a given axis of rotation. Designed for integration with a microelectromechanical systems-based fully implantable vestibular prosthesis, this sensing method can provide substantial power savings when compared with contemporary gyroscopes.
Collapse
Affiliation(s)
- Pamela T Bhatti
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0250, USA.
| | | |
Collapse
|
27
|
Demosthenous A, Perkins T, Donaldson N. A Stimulator ASIC Featuring Versatile Management for Vestibular Prostheses. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2011; 5:147-159. [PMID: 23851203 DOI: 10.1109/tbcas.2011.2138139] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper presents a multichannel stimulator ASIC for an implantable vestibular prosthesis. The system features versatile stimulation management which allows fine setting of the parameters for biphasic stimulation pulses. To address the problem of charge imbalance due to rounding errors, the digital processor can calculate and provide accurate charge correction. A technique to reduce the data rate to the stimulator is described. The stimulator ASIC was implemented in 0.6-μ m high-voltage CMOS technology occupying an area of 2.27 mm(2). The measured performance of the ASIC has been verified using vestibular electrodes in saline.
Collapse
|
28
|
Sooksood K, Stieglitz T, Ortmanns M. An active approach for charge balancing in functional electrical stimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2010; 4:162-170. [PMID: 23853340 DOI: 10.1109/tbcas.2010.2040277] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Charge balancing is a major concern in functional electrical stimulation, since any excess charge accumulation over time leads to electrolysis with electrode dissolution and tissue destruction. This paper presents a new active approach for charge balancing using long-term offset regulation. Therefore, the electrode voltage is briefly monitored after each stimulation cycle and checked if it remains within a predefined voltage range. If not, an offset current is adjusted in order to track the biphasic current mismatch in upcoming stimulations. This technique is compared to a previously introduced active charge balancer as well as commonly used passive balancing techniques. Subsequently, the techniques are verified through experiments on a platinum black electrode in 0.9% saline solution.
Collapse
|