1
|
Rivkin B, Akbar F, Otto M, Beyer L, Paul B, Kosiba K, Gustmann T, Hufenbach J, Medina-Sánchez M. Remotely Controlled Electrochemical Degradation of Metallic Implants. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2307742. [PMID: 38326101 DOI: 10.1002/smll.202307742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/22/2024] [Indexed: 02/09/2024]
Abstract
Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.
Collapse
Affiliation(s)
- Boris Rivkin
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Farzin Akbar
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Martin Otto
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Institute of Materials Science, Technische Universität Bergakademie Freiberg, 09599, Freiberg, Germany
| | - Lukas Beyer
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Institute of Materials Science, Technische Universität Bergakademie Freiberg, 09599, Freiberg, Germany
| | - Birgit Paul
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Konrad Kosiba
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Tobias Gustmann
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
| | - Julia Hufenbach
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Institute of Materials Science, Technische Universität Bergakademie Freiberg, 09599, Freiberg, Germany
| | - Mariana Medina-Sánchez
- Leibniz Institute for Solid State and Materials Research (IFW), 01069, Dresden, Germany
- Center for Molecular Bioengineering (B CUBE), Chair of Micro- and Nano Systems, Technische Universität Dresden, 01307, Dresden, Germany
- CIC nanoGUNE-BRTA, Donostia-San Sebastián, 20018, Spain
- Ikerbasque, Basque Foundation for Science, Bilbao, 48013, Spain
| |
Collapse
|
2
|
Benbuk A, Gulick D, Moniz-Garcia D, Liu S, Quinones-Hinojosa A, Christen JB. Wireless Stimulation of Motor Cortex Through a Collagen Dura Substitute Using an Ultra-Thin Implant Fabricated on Parylene/PDMS. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:334-346. [PMID: 37910421 PMCID: PMC11080957 DOI: 10.1109/tbcas.2023.3329447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
We present the design, fabrication, and in vivo testing of an ultra-thin (100 μm) wireless and battery-free implant for stimulation of the brain's cortex. The implant is fabricated on a flexible and transparent parylene/PDMS substrate, and it is miniaturized to dimensions of 15.6 × 6.6 mm 2. The frequency and pulse width of the monophasic voltage pulses are determined through On-Off keying (OOK) modulation of a wireless transmission at 2.45 GHz. Furthermore, the implant triggered a motor response in vivo when tested in 6 rodents. Limb response was observed by wireless stimulation of the brain's motor cortex through an FDA-approved collagen dura substitute that was placed on the dura in the craniotomy site, with no direct contact between the implant's electrodes and the brain's cortical surface. Therefore, the wireless stimulation method reported herein enables the concept of an e-dura substitute, where wireless electronics can be integrated onto a conventional dura substitute to augment its therapeutic function and administer any desired stimulation protocol without the need for post-surgical intervention for battery replacement or reprogramming stimulation parameters.
Collapse
|
3
|
Jia Q, Liu Y, Lv S, Wang Y, Jiao P, Xu W, Xu Z, Wang M, Cai X. Wireless closed-loop deep brain stimulation using microelectrode array probes. J Zhejiang Univ Sci B 2024; 25:803-823. [PMID: 39420519 PMCID: PMC11494161 DOI: 10.1631/jzus.b2300400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 08/25/2023] [Indexed: 03/02/2024]
Abstract
Deep brain stimulation (DBS), including optical stimulation and electrical stimulation, has been demonstrated considerable value in exploring pathological brain activity and developing treatments for neural disorders. Advances in DBS microsystems based on implantable microelectrode array (MEA) probes have opened up new opportunities for closed-loop DBS (CL-DBS) in situ. This technology can be used to detect damaged brain circuits and test the therapeutic potential for modulating the output of these circuits in a variety of diseases simultaneously. Despite the success and rapid utilization of MEA probe-based CL-DBS microsystems, key challenges, including excessive wired communication, need to be urgently resolved. In this review, we considered recent advances in MEA probe-based wireless CL-DBS microsystems and outlined the major issues and promising prospects in this field. This technology has the potential to offer novel therapeutic options for psychiatric disorders in the future.
Collapse
Affiliation(s)
- Qianli Jia
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yaoyao Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Shiya Lv
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yiding Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Peiyao Jiao
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhaojie Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Mixia Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China. ,
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China. ,
| |
Collapse
|
4
|
Miziev S, Pawlak WA, Howard N. Comparative analysis of energy transfer mechanisms for neural implants. Front Neurosci 2024; 17:1320441. [PMID: 38292898 PMCID: PMC10825050 DOI: 10.3389/fnins.2023.1320441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 12/19/2023] [Indexed: 02/01/2024] Open
Abstract
As neural implant technologies advance rapidly, a nuanced understanding of their powering mechanisms becomes indispensable, especially given the long-term biocompatibility risks like oxidative stress and inflammation, which can be aggravated by recurrent surgeries, including battery replacements. This review delves into a comprehensive analysis, starting with biocompatibility considerations for both energy storage units and transfer methods. The review focuses on four main mechanisms for powering neural implants: Electromagnetic, Acoustic, Optical, and Direct Connection to the Body. Among these, Electromagnetic Methods include techniques such as Near-Field Communication (RF). Acoustic methods using high-frequency ultrasound offer advantages in power transmission efficiency and multi-node interrogation capabilities. Optical methods, although still in early development, show promising energy transmission efficiencies using Near-Infrared (NIR) light while avoiding electromagnetic interference. Direct connections, while efficient, pose substantial safety risks, including infection and micromotion disturbances within neural tissue. The review employs key metrics such as specific absorption rate (SAR) and energy transfer efficiency for a nuanced evaluation of these methods. It also discusses recent innovations like the Sectored-Multi Ring Ultrasonic Transducer (S-MRUT), Stentrode, and Neural Dust. Ultimately, this review aims to help researchers, clinicians, and engineers better understand the challenges of and potentially create new solutions for powering neural implants.
Collapse
|
5
|
DAS D, Xu Z, Nasrollahpour M, Martos-Repath I, Zaeimbashi M, Khalifa A, Mittal A, Cash SS, Sun NX, Shrivastava A, Onabajo M. Circuit-Level Modeling and Simulation of Wireless Sensing and Energy Harvesting With Hybrid Magnetoelectric Antennas for Implantable Neural Devices. IEEE OPEN JOURNAL OF CIRCUITS AND SYSTEMS 2023; 4:139-155. [PMID: 37829556 PMCID: PMC10569408 DOI: 10.1109/ojcas.2023.3259233] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/14/2023]
Abstract
A magnetoelectric antenna (ME) can exhibit the dual capabilities of wireless energy harvesting and sensing at different frequencies. In this article, a behavioral circuit model for hybrid ME antennas is described to emulate the radio frequency (RF) energy harvesting and sensing operations during circuit simulations. The ME antenna of this work is interfaced with a CMOS energy harvester chip towards the goal of developing a wireless communication link for fully integrated implantable devices. One role of the integrated system is to receive pulse-modulated power from a nearby transmitter, and another role is to sense and transmit low-magnitude neural signals. The measurements reported in this paper are the first results that demonstrate simultaneous low-frequency wireless magnetic sensing and high-frequency wireless energy harvesting at two different frequencies with one dual-mode ME antenna. The proposed behavioral ME antenna model can be utilized during design optimizations of energy harvesting circuits. Measurements were performed to validate the wireless power transfer link with an ME antenna having a 2.57 GHz resonance frequency connected to an energy harvester chip designed in 65nm CMOS technology. Furthermore, this dual-mode ME antenna enables concurrent sensing using a carrier signal with a frequency that matches the second 63.63 MHz resonance mode. A wireless test platform has been developed for evaluation of ME antennas as a tool for neural implant design, and this prototype system was utilized to provide first experimental results with the transmission of magnetically modulated action potential waveforms.
Collapse
Affiliation(s)
- Diptashree DAS
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Ziyue Xu
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Mehdi Nasrollahpour
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
- MediaTek Inc., Woburn, MA 01801, USA
| | - Isabel Martos-Repath
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Mohsen Zaeimbashi
- The Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Adam Khalifa
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Ankit Mittal
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Sydney S Cash
- Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Nian X Sun
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Aatmesh Shrivastava
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Marvin Onabajo
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| |
Collapse
|
6
|
Benbuk A, Esmaeili H, Liu S, Patino-Guerrero A, Migrino RQ, Chae J, Nikkhah M, Blain Christen J. Passive and Flexible Wireless Electronics Fabricated on Parylene/PDMS Substrate for Stimulation of Human Stem Cell-Derived Cardiomyocytes. ACS Sens 2022; 7:3287-3297. [PMID: 36281962 PMCID: PMC9706816 DOI: 10.1021/acssensors.2c00794] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
In this paper, we report the development of a wireless, passive, biocompatible, and flexible system for stimulation of human induced pluripotent stem cell derived cardiomyocytes (hiPSC-CMS). Fabricated on a transparent parylene/PDMS substrate, the proposed stimulator enables real-time excitation and characterization of hiPSC-CMs cultured on-board. The device comprises a rectenna operating at 2.35 GHz which receives radio frequency (RF) energy from an external transmitter and converts it into DC voltage to deliver monophasic stimulation. The operation of the stimulator was primarily verified by delivering monophasic voltage pulses through gold electrodes to hiPSC-CMs cultured on the Matrigel-coated substrates. Stimulated hiPSC-CMs beat in accordance with the monophasic pulses when delivered at 0.5, 1, and 2 Hz pulsing frequency, while no significant cell death was observed. The wireless stimulator could generate monophasic pulses with an amplitude of 8 V at a distance of 15 mm. These results demonstrated the proposed wireless stimulator's efficacy for providing electrical stimulation to engineered cardiac tissues. The proposed stimulator will have a wide application in tissue engineering where a fully wireless stimulation of electroconductive cells is needed. The device also has potential to be employed as a cardiac stimulator by delivering external stimulation and regulating the contractions of cardiac tissue.
Collapse
Affiliation(s)
- Ahmed
Abed Benbuk
- School of
Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287-5706, United States
| | - Hamid Esmaeili
- School
of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona 85281, United States
| | - Shiyi Liu
- School of
Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287-5706, United States
| | - Alejandra Patino-Guerrero
- School
of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona 85281, United States
| | - Raymond Q. Migrino
- Phoenix
Veterans Affairs Health Care System, Phoenix, Arizona 85022, United States,University
of Arizona College of Medicine, Phoenix, Arizona 85004, United States
| | - Junseok Chae
- School of
Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287-5706, United States
| | - Mehdi Nikkhah
- School
of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona 85281, United States,Center
for Personalized Diagnostics (CPD), Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States,
| | - Jennifer Blain Christen
- School of
Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287-5706, United States,
| |
Collapse
|
7
|
Habibagahi I, Omidbeigi M, Hadaya J, Lyu H, Jang J, Ardell JL, Bari AA, Babakhani A. Vagus nerve stimulation using a miniaturized wirelessly powered stimulator in pigs. Sci Rep 2022; 12:8184. [PMID: 35581302 PMCID: PMC9114380 DOI: 10.1038/s41598-022-11850-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 04/26/2022] [Indexed: 11/09/2022] Open
Abstract
Neuromodulation of peripheral nerves has been clinically used for a wide range of indications. Wireless and batteryless stimulators offer important capabilities such as no need for reoperation, and extended life compared to their wired counterparts. However, there are challenging trade-offs between the device size and its operating range, which can limit their use. This study aimed to examine the functionality of newly designed wirelessly powered and controlled implants in vagus nerve stimulation for pigs. The implant used near field inductive coupling at 13.56 MHz industrial, scientific, and medical band to harvest power from an external coil. The circular implant had a diameter of 13 mm and weighed 483 mg with cuff electrodes. The efficiency of the inductive link and robustness to distance and misalignment were optimized. As a result, the specific absorption rate was orders of magnitude lower than the safety limit, and the stimulation can be performed using only 0.1 W of external power. For the first time, wireless and batteryless VNS with more than 5 cm operation range was demonstrated in pigs. A total of 84 vagus nerve stimulations (10 s each) have been performed in three adult pigs. In a quantitative comparison of the effectiveness of VNS devices, the efficiency of systems on reducing heart rate was similar in both conventional (75%) and wireless (78.5%) systems. The pulse width and frequency of the stimulation were swept on both systems, and the response for physiological markers was drawn. The results were easily reproducible, and methods used in this study can serve as a basis for future wirelessly powered implants.
Collapse
Affiliation(s)
- Iman Habibagahi
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA.
| | - Mahmoud Omidbeigi
- Department of Neurosurgery, University of California at Los Angeles, Los Angeles, CA, USA.
| | - Joseph Hadaya
- UCLA Cardiac Arrhythmia Center, University of California Los Angeles, Los Angeles, CA, USA.,UCLA Neurocardiology Research Program of Excellence, University of California Los Angeles, Los Angeles, CA, USA.,Molecular, Cellular and Integrative Physiology Program, University of California Los Angeles, Los Angeles, CA, USA
| | - Hongming Lyu
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA
| | - Jaeeun Jang
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA
| | - Jeffrey L Ardell
- UCLA Cardiac Arrhythmia Center, University of California Los Angeles, Los Angeles, CA, USA.,UCLA Neurocardiology Research Program of Excellence, University of California Los Angeles, Los Angeles, CA, USA
| | - Ausaf A Bari
- Department of Neurosurgery, University of California at Los Angeles, Los Angeles, CA, USA
| | - Aydin Babakhani
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
8
|
Fully Implantable Neural Stimulator with Variable Parameters. ELECTRONICS 2022. [DOI: 10.3390/electronics11071104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Neural implantable systems have promoted the development of neurosurgery research and clinical practice. However, traditional tethered neural implants use physical wires for power supply and signal transmission, which have many restrictions on implant targets. Therefore, untethered, wireless, and controllable neural stimulation has always been widely recognized as the engineering goal of neural implants. In this paper, magnetically coupled resonant wireless power transfer (MCR-WPT) technology is adopted to design and manufacture a wireless stimulator for the electrical stimulation experiment of nerve repair. In the process of device development, SCM technology, signal modulation, demodulation, wireless power supply, and integration/packaging are used. Through experimental tests, the stimulator can output single-phase pulse signals with a variable frequency of (1–20 Hz), a duty cycle of (1–50%), and voltage. The average power is approximately 25 mW. The minimum pulse width of the signal is 200 μs and the effective distance of transmission is 1–4 cm. The stimulator can perform low-frequency, safe and controllable wireless stimulation.
Collapse
|
9
|
Wang W, Pun KP, Zhao B. A Current-Switching Technique for Intra-Body Communication With Miniaturized Electrodes. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:1343-1353. [PMID: 34748499 DOI: 10.1109/tbcas.2021.3125422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Medical implants are required to be minimized in size to alleviate surgical pains. Battery and antenna are often the main bottlenecks in system miniaturization. Wireless power transfer (WPT) is a possible way to minimize or eliminate the battery. Medical implants with WPT often use backscattering for data communication due to its low power consumption and low hardware cost. However, the conventional backscattering approach with WPT requires a large implanted antenna to ensure a relatively high efficiency and enough signal-to-noise ratio (SNR) for demodulation. In this work, we propose a current-switching technique for intra-body communication to achieve a high SNR and data rate with a pair of small implanted electrodes. Instead of the conventional electric-field based WPT and communication, a current loop is configured in the body tissue for WPT, where a new passive-communication scheme is implemented at the same time. A prototype is implemented to validate the proposed technique, in which the implanted electrodes are designed to be as small as 200 μm × 200 μm, located 13 mm deep in the tissue. The system achieves a communication rate of 10 Mbps with a bit error rate (BER) of 8.4 ×10-4 over the 406 MHz MedRadio band, while the signal-to-blocker ratio and SNR are measured to be -35.7 dB and 12.4dB, respectively.
Collapse
|
10
|
Kopyl S, Surmenev R, Surmeneva M, Fetisov Y, Kholkin A. Magnetoelectric effect: principles and applications in biology and medicine- a review. Mater Today Bio 2021; 12:100149. [PMID: 34746734 PMCID: PMC8554634 DOI: 10.1016/j.mtbio.2021.100149] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 10/05/2021] [Accepted: 10/08/2021] [Indexed: 12/26/2022] Open
Abstract
Magnetoelectric (ME) effect experimentally discovered about 60 years ago remains one of the promising research fields with the main applications in microelectronics and sensors. However, its applications to biology and medicine are still in their infancy. For the diagnosis and treatment of diseases at the intracellular level, it is necessary to develop a maximally non-invasive way of local stimulation of individual neurons, navigation, and distribution of biomolecules in damaged cells with relatively high efficiency and adequate spatial and temporal resolution. Recently developed ME materials (composites), which combine elastically coupled piezoelectric (PE) and magnetostrictive (MS) phases, have been shown to yield very strong ME effects even at room temperature. This makes them a promising toolbox for solving many problems of modern medicine. The main ME materials, processing technologies, as well as most prospective biomedical applications will be overviewed, and modern trends in using ME materials for future therapies, wireless power transfer, and optogenetics will be considered.
Collapse
Affiliation(s)
- S. Kopyl
- Department of Physics & CICECO - Aveiro Institute of Materials, University of Aveiro, Aveiro, Portugal
| | - R. Surmenev
- Physical Materials Science and Composite Materials Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
- Piezo- and Magnetoelectric Materials Research & Development Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - M. Surmeneva
- Physical Materials Science and Composite Materials Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
- Piezo- and Magnetoelectric Materials Research & Development Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Y. Fetisov
- Research & Education Centre ‘Magnetoelectric Materials and Devices’, MIREA – Russian Technological University, Moscow, Russia
| | - A. Kholkin
- Department of Physics & CICECO - Aveiro Institute of Materials, University of Aveiro, Aveiro, Portugal
- Piezo- and Magnetoelectric Materials Research & Development Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
- School of Natural Sciences and Mathematics, Ural Federal University, Ekaterinburg, Russia
| |
Collapse
|
11
|
Ultra-compact dual-band smart NEMS magnetoelectric antennas for simultaneous wireless energy harvesting and magnetic field sensing. Nat Commun 2021; 12:3141. [PMID: 34035237 PMCID: PMC8149822 DOI: 10.1038/s41467-021-23256-z] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Accepted: 04/13/2021] [Indexed: 11/12/2022] Open
Abstract
Ultra-compact wireless implantable medical devices are in great demand for healthcare applications, in particular for neural recording and stimulation. Current implantable technologies based on miniaturized micro-coils suffer from low wireless power transfer efficiency (PTE) and are not always compliant with the specific absorption rate imposed by the Federal Communications Commission. Moreover, current implantable devices are reliant on differential recording of voltage or current across space and require direct contact between electrode and tissue. Here, we show an ultra-compact dual-band smart nanoelectromechanical systems magnetoelectric (ME) antenna with a size of 250 × 174 µm2 that can efficiently perform wireless energy harvesting and sense ultra-small magnetic fields. The proposed ME antenna has a wireless PTE 1–2 orders of magnitude higher than any other reported miniaturized micro-coil, allowing the wireless IMDs to be compliant with the SAR limit. Furthermore, the antenna’s magnetic field detectivity of 300–500 pT allows the IMDs to record neural magnetic fields. Wireless implantable medical devices (IMDs) are hamstrung by both size and efficiency required for wireless power transfer. Here, Zaeimbashi et al. present a magnetoelectric nano-electromechanical systems that can harvest energy and sense weak magnetic fields like those arising from neural activity.
Collapse
|
12
|
Lyu H, Babakhani A. A 13.56-MHz -25-dBm-Sensitivity Inductive Power Receiver System-on-a-Chip With a Self-Adaptive Successive Approximation Resonance Compensation Front-End for Ultra-Low-Power Medical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:80-90. [PMID: 33373302 PMCID: PMC9215201 DOI: 10.1109/tbcas.2020.3047827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Battery-less and ultra-low-power implantable medical devices (IMDs) with minimal invasiveness are the latest therapeutic paradigm. This work presents a 13.56-MHz inductive power receiver system-on-a-chip with an input sensitivity of -25.4 dBm (2.88 μW) and an efficiency of 46.4% while driving a light load of 30 μW. In particular, a real-time resonance compensation scheme is proposed to mitigate resonance variations commonly seen in IMDs due to different dielectric environments, loading conditions, and fabrication mismatches, etc. The power-receiving front-end incorporates a 6-bit capacitor bank that is periodically adjusted according to a successive-approximation-resonance-tuning (SART) algorithm. The compensation range is as much as 24 pF and it converges within 12 clock cycles and causes negligible power consumption overhead. The harvested voltage from 1.7 V to 3.3 V is digitized on-chip and transmitted via an ultra-wideband impulse radio (IR-UWB) back-telemetry for closed-loop regulation. The IC is fabricated in 180-nm CMOS process with an overall current dissipation of 750 nA. At a separation distance of 2 cm, the end-to-end power transfer efficiency reaches 16.1% while driving the 30-μW load, which is immune to artificially induced resonance capacitor offsets. The proposed system can be applied to various battery-less IMDs with the potential improvement of the power transfer efficiency on orders of magnitude.
Collapse
|
13
|
Abstract
Wireless power transmission (WPT) is a critical technology that provides an alternative for wireless power and communication with implantable medical devices (IMDs). This article provides a study concentrating on popular WPT techniques for IMDs including inductive coupling, microwave, ultrasound, and hybrid wireless power transmission (HWPT) systems. Moreover, an overview of the major works is analyzed with a comparison of the symmetric and asymmetric design elements, operating frequency, distance, efficiency, and harvested power. In general, with respect to the operating frequency, it is concluded that the ultrasound-based and inductive-based WPTs have a low operating frequency of less than 50 MHz, whereas the microwave-based WPT works at a higher frequency. Moreover, it can be seen that most of the implanted receiver’s dimension is less than 30 mm for all the WPT-based methods. Furthermore, the HWPT system has a larger receiver size compared to the other methods used. In terms of efficiency, the maximum power transfer efficiency is conducted via inductive-based WPT at 95%, compared to the achievable frequencies of 78%, 50%, and 17% for microwave-based, ultrasound-based, and hybrid WPT, respectively. In general, the inductive coupling tactic is mostly employed for transmission of energy to neuro-stimulators, and the ultrasonic method is used for deep-seated implants.
Collapse
|
14
|
Yu Z, Chen JC, Alrashdan FT, Avants BW, He Y, Singer A, Robinson JT, Yang K. MagNI: A Magnetoelectrically Powered and Controlled Wireless Neurostimulating Implant. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:1241-1252. [PMID: 33180732 PMCID: PMC8712272 DOI: 10.1109/tbcas.2020.3037862] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
This paper presents the first wireless and programmable neural stimulator leveraging magnetoelectric (ME) effects for power and data transfer. Thanks to low tissue absorption, low misalignment sensitivity and high power transfer efficiency, the ME effect enables safe delivery of high power levels (a few milliwatts) at low resonant frequencies ( ∼ 250 kHz) to mm-sized implants deep inside the body (30-mm depth). The presented MagNI (Magnetoelectric Neural Implant) consists of a 1.5-mm 2 180-nm CMOS chip, an in-house built 4 × 2 mm ME film, an energy storage capacitor, and on-board electrodes on a flexible polyimide substrate with a total volume of 8.2 mm 3. The chip with a power consumption of 23.7 μW includes robust system control and data recovery mechanisms under source amplitude variations (1-V variation tolerance). The system delivers fully-programmable bi-phasic current-controlled stimulation with patterns covering 0.05-to-1.5-mA amplitude, 64-to-512- μs pulse width, and 0-to-200-Hz repetition frequency for neurostimulation.
Collapse
|
15
|
Lyu H, Wang Z, Babakhani A. A UHF/UWB Hybrid RFID Tag With a 51-m Energy-Harvesting Sensitivity for Remote Vital-Sign Monitoring. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES 2020; 68:4886-4895. [PMID: 36337340 PMCID: PMC9632603 DOI: 10.1109/tmtt.2020.3017674] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A novel ultra-high frequency (UHF)/ultra-wideband (UWB) hybrid RFID tag is reported for object-specific remote vital-sign monitoring application. The tag achieves a record energy-harvesting sensitivity at UHF band by codesigning a meander dipole antenna and a passive rectifier. The especially high quality-factor makes the frontend sensitive to near-field motions such as heartbeats and respiration in a wearable setting. The custom CMOS IC of approximately 1-μW power consumption builds around a low-power UWB transmitter and converts variations of the supply voltage to the impulse repetition rate. The tag consisting of the IC and UHF/UWB antennas requires no other discrete components and features a size of 4.2 cm × 2.9 cm and a weight of 0.93 g. A long-distance experiment verifies that the tag can be wirelessly powered up at 51 meters from a 4-W equivalent-isotropic-radiation-power (EIRP) UHF transmitter. Remote vital-sign monitoring is validated on a human subject, in which the UHF power source is placed 2 meters away from the subject with a power emission of less than 20 dBm. This work proposes a first-of-its-kind remote vital-sign monitoring scheme based on a noncontact wearable tag. The design of the far-field energy-harvesting frontend with a record sensitivity serves as a reference for future works on battery-free remote sensors.
Collapse
Affiliation(s)
- Hongming Lyu
- Department of Electrical and Computer Engineering, University of California Los Angeles, CA 90095 USA
| | - Zeyu Wang
- Department of Electrical and Computer Engineering, University of California Los Angeles, CA 90095 USA
| | - Aydin Babakhani
- Department of Electrical and Computer Engineering, University of California Los Angeles, CA 90095 USA
| |
Collapse
|
16
|
Akgun OC, Nanbakhsh K, Giagka V, Serdijn WA. A Chip Integrity Monitor for Evaluating Moisture/Ion Ingress in mm-Sized Single-Chip Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:658-670. [PMID: 32746351 DOI: 10.1109/tbcas.2020.3007484] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
For mm-sized implants incorporating silicon integrated circuits, ensuring lifetime operation of the chip within the corrosive environment of the body still remains a critical challenge. For the chip's packaging, various polymeric and thin ceramic coatings have been reported, demonstrating high biocompatibility and barrier properties. Yet, for the evaluation of the packaging and lifetime prediction, the conventional helium leak test method can no longer be applied due to the mm-size of such implants. Alternatively, accelerated soak studies are typically used instead. For such studies, early detection of moisture/ion ingress using an in-situ platform may result in a better prediction of lifetime functionality. In this work, we have developed such a platform on a CMOS chip. Ingress of moisture/ions would result in changes in the resistance of the interlayer dielectrics (ILD) used within the chip and can be tracked using the proposed system, which consists of a sensing array and an on-chip measurement engine. The measurement system uses a novel charge/discharge based time-mode resistance sensor that can be implemented using simple yet highly robust circuitry. The sensor array is implemented together with the measurement engine in a standard 0.18 μm 6-metal CMOS process. The platform was validated through a series of dry and wet measurements. The system can measure the ILD resistance with values of up to 0.504 peta-ohms, with controllable measurement steps that can be as low as 0.8 M Ω. The system works with a supply voltage of 1.8 V, and consumes 4.78 mA. Wet measurements in saline demonstrated the sensitivity of the platform in detecting moisture/ion ingress. Such a platform could be used both in accelerated soak studies and during the implant's life-time for monitoring the integrity of the chip's packaging.
Collapse
|
17
|
Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers. Sci Rep 2020; 10:2067. [PMID: 32034237 PMCID: PMC7005712 DOI: 10.1038/s41598-020-59017-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Accepted: 01/22/2020] [Indexed: 11/15/2022] Open
Abstract
About 30% of patients with impaired cardiac function have ventricular dyssynchrony and seek cardiac resynchronization therapy (CRT). In this study, we demonstrate synchronized biventricular (BiV) pacing in a leadless fashion by implementing miniaturized and wirelessly powered pacemakers. With their flexible form factors, two pacemakers were implanted epicardially on the right and left ventricles of a porcine model and were inductively powered at 13.56 MHz and 40.68 MHz industrial, scientific, and medical (ISM) bands, respectively. The power consumption of these pacemakers is reduced to µW-level by a novel integrated circuit design, which considerably extends the maximum operating distance. Leadless BiV pacing is demonstrated for the first time in both open-chest and closed-chest porcine settings. The clinical outcomes associated with different interventricular delays are verified through electrophysiologic and hemodynamic responses. The closed-chest pacing only requires the external source power of 0.3 W and 0.8 W at 13.56 MHz and 40.68 MHz, respectively, which leads to specific absorption rates (SARs) 2–3 orders of magnitude lower than the safety regulation limit. This work serves as a basis for future wirelessly powered leadless pacemakers that address various cardiac resynchronization challenges.
Collapse
|
18
|
Zhang Z, Alwen A, Lyu H, Liu X, Li Z, Xie Z, Xie Y, Guan F, Babakhani A, Pei Q. Stretchable Transparent Wireless Charging Coil Fabricated by Negative Transfer Printing. ACS APPLIED MATERIALS & INTERFACES 2019; 11:40677-40684. [PMID: 31589402 DOI: 10.1021/acsami.9b14728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Wearable electronics, such as smartwatches, VR (virtual reality)/AR (augmented reality) smartglasses, and E-textiles, are an emerging technology platform that is reshaping the way people interact with the surrounding world. However, the power source of these devices can be a critical issue, causing short operational/standby times and frequent charging. Here, a stretchable transparent wireless charging coil fabricated by negative adhesive transfer printing (NATP) is demonstrated. The stretchable transparent conductor is based on the silver nanowire (AgNW)-polyurethane acrylate (PUA) composite with high conductivity and robustness under harsh mechanical treatment. A 10.6 ohm/sq thin film has a transmittance of 84% and is still conductive under a mechanical deformation up to 60% tensile strain. A maximum power of 59 mW (power transfer efficiency ∼24%) is transferred wirelessly. A green-light-emitting diode (LED) was wirelessly powered to illustratively demonstrate the functionality of the system. This work provides an alternative power solution which is compatible with the soft and flexible components of wearable devices.
Collapse
|
19
|
Khalifa A, Liu Y, Karimi Y, Wang Q, Eisape A, Stanacevic M, Thakor N, Bao Z, Etienne-Cummings R. The Microbead: A 0.009 mm 3 Implantable Wireless Neural Stimulator. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:971-985. [PMID: 31484132 DOI: 10.1109/tbcas.2019.2939014] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Wirelessly powered implants are increasingly being developed to interface with neurons in the brain. They often rely on microelectrode arrays, which are limited by their ability to cover large cortical surface areas and long-term stability because of their physical size and rigid configuration. Yet some clinical and research applications prioritize a distributed neural interface over one that offers high channel count. One solution to make large scale, fully specifiable, electrical stimulation/recording possible, is to disconnect the electrodes from the base, so that they can be arbitrarily placed freely in the nervous system. In this work, a wirelessly powered stimulating implant is miniaturized using a novel electrode integration technique, and its implanted depth maximized using new optimization design methods for the transmitter and receiver coils. The stimulating device is implemented in a 130 nm CMOS technology with the following characteristics: 300 μm × 300 μm × 80 μm size; optimized two-coil inductive link; and integrated circuit, electrodes and coil. The wireless and stimulation capability of the implant is demonstrated in a conductive medium, as well as in-vivo. To the best of our knowledge, the fabricated free-floating miniaturized implant has the best depth-to-volume ratio making it an excellent tool for minimally-invasive distributed neural interface, and thus could eventually complement or replace the rigid arrays that are currently the state-of-the-art in brain set-ups.
Collapse
|
20
|
Zaeimbashi M, Lin H, Dong C, Liang X, Nasrollahpour M, Chen H, Sun N, Matyushov A, He Y, Wang X, Tu C, Wei Y, Zhang Y, Cash SS, Onabajo M, Shrivastava A, Sun N. NanoNeuroRFID: A Wireless Implantable Device Based on Magnetoelectric Antennas. ACTA ACUST UNITED AC 2019. [DOI: 10.1109/jerm.2019.2903930] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
21
|
Lyu H, Gad P, Zhong H, Edgerton VR, Babakhani A. A 430-MHz Wirelessly Powered Implantable Pulse Generator With Intensity/Rate Control and Sub-1 μA Quiescent Current Consumption. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:180-190. [PMID: 30418917 DOI: 10.1109/tbcas.2018.2879357] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This work presents a miniaturized μW-level implantable pulse generator (IPG) inductively powered at 430 MHz. Notches are intentionally applied to the incident power, which are replicated to precisely control the timing of the output pulses. Fabricated in a 180-nm CMOS process, the concise circuitry occupies a pad-included footprint of 850 μm × 450 μm and achieves a quiescent current consumption of 950 nA. To reduce the form factor, 401-457 MHz MedRadio-band is utilized to realize the induction link. The finalized assembly achieves one of the smallest dimensions (4.6 mm × 7.0 mm) for near-field IPGs with the Rx coil size of 4.5 mm × 3.6 mm. Codesign of the rectifier and Rx coil accommodates the possible resonant frequency drifts in biological tissues. In the benchtop measurement, a 430-MHz Tx coil is demonstrated to operate the IPG at 4.5 and 4 cm proximities in the air and through water, respectively. An in vivo experiment has been performed, in which the IPG was implanted on the hindlimb muscle belly of an anesthetized rat with the connective tissue and skin sutured. The electrical stimuli induced the isolated ankle flexion at specific strengths and rates, and the experiment complies with the specific absorption rate regulations. This work shows the potential for applications requiring stringent form factors and high sensitivities.
Collapse
|