1
|
Sakthivelpathi V, Li T, Qian Z, Lee C, Taylor Z, Chung JH. Advancements and Applications of Micro and Nanostructured Capacitive Sensors: A Review. SENSORS AND ACTUATORS. A, PHYSICAL 2024; 377:115701. [PMID: 39129941 PMCID: PMC11308742 DOI: 10.1016/j.sna.2024.115701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/13/2024]
Abstract
Capacitors are essential components in modern electrical systems, functioning primarily to store electrical charges and regulate current flow. Capacitive sensors, developed in the 20th century, have become crucial in various applications, including touchscreens and smart devices, due to their ability to detect both metallic and non-metallic objects with high sensitivity and low energy consumption. The advancement of microelectromechanical systems (MEMS) and nanotechnology has significantly enhanced the capabilities of capacitive sensors, leading to unprecedented sensitivity, dynamic range, and cost-effectiveness. These sensors are integral to modern devices, enabling precise measurements of proximity, pressure, strain, and other parameters. This review provides a comprehensive overview of the development, fabrication, and integration of micro and nanostructured capacitive sensors. In terms of an electric field, the working and detection principles are discussed with analytical equations and our numerical results. The focus extends to novel fabrication methods using advanced materials to enhance sensitivities for various parameters, such as proximity, force, pressure, strain, temperature, humidity, and liquid sensing. Their applications are demonstrated in wearable devices, human-machine interfaces, biomedical sensing, health monitoring, robotics control, industrial monitoring, and molecular detection. By consolidating existing research, this review offers insights into the advancements and future directions of capacitive sensor technology.
Collapse
Affiliation(s)
| | - Tianyi Li
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Zhongjie Qian
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Changwoo Lee
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Zachary Taylor
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| | - Jae-Hyun Chung
- Mechanical Engineering, University of Washington, Seattle, WA, USA 98195
| |
Collapse
|
2
|
Kim J, Noh S, Park JA, Park SC, Park SJ, Lee JH, Ahn JH, Lee T. Recent Advances in Aptasensor for Cytokine Detection: A Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:8491. [PMID: 34960590 PMCID: PMC8705356 DOI: 10.3390/s21248491] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/03/2021] [Accepted: 12/12/2021] [Indexed: 12/14/2022]
Abstract
Cytokines are proteins secreted by immune cells. They promote cell signal transduction and are involved in cell replication, death, and recovery. Cytokines are immune modulators, but their excessive secretion causes uncontrolled inflammation that attacks normal cells. Considering the properties of cytokines, monitoring the secretion of cytokines in vivo is of great value for medical and biological research. In this review, we offer a report on recent studies for cytokine detection, especially studies on aptasensors using aptamers. Aptamers are single strand nucleic acids that form a stable three-dimensional structure and have been receiving attention due to various characteristics such as simple production methods, low molecular weight, and ease of modification while performing a physiological role similar to antibodies.
Collapse
Affiliation(s)
- Jinmyeong Kim
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| | - Seungwoo Noh
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| | - Jeong Ah Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| | - Sang-Chan Park
- Department of Electronics Engineering, Chungnam National University, 99 Yuseong-gu, Daejeon 34134, Korea;
| | - Seong Jun Park
- Department of Electrical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea;
| | - Jin-Ho Lee
- School of Biomedical Convergence Engineering, Pusan National University, 49 Busandaehak-ro, Yangsan 50612, Korea;
| | - Jae-Hyuk Ahn
- Department of Electronics Engineering, Chungnam National University, 99 Yuseong-gu, Daejeon 34134, Korea;
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-gu, Seoul 01897, Korea; (J.K.); (S.N.); (J.A.P.)
| |
Collapse
|
3
|
Fluorescent paper strip immunoassay with carbon nanodots@silica for determination of human serum amyloid A1. Mikrochim Acta 2021; 188:386. [PMID: 34664145 DOI: 10.1007/s00604-021-05019-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 09/05/2021] [Indexed: 10/20/2022]
Abstract
A fluorescent paper strip immunoassay in conjunction with carbon nanodots@silica (CND@SiO2) as a label was developed for the quantitative measurements of human serum amyloid A1 (hSAA1) in serum at clinically significant concentrations for lung cancer diagnosis. Monodispersed CND@SiO2 was prepared by cohydrolysis between silane-crosslinked carbon nanodots and silica precursors via the Ströber method and further attached covalently to anti-hSAA1 (14F8) monoclonal antibody [anti-hSAA1(14F8)] specific to the hSAA1 target. The hSAA1 concentrations were then determined by quantifying the blue fluorescence intensity upon 365 nm excitation of the captured hSAA1 with anti-hSAA1(14F8)-CND@SiO2 conjugates in the test line on a paper strip where anti-hSAA1 (10G1) monoclonal antibody was physisorbed. The developed fluorescent paper strip with CND@SiO2 can detect hSAA1 at concentrations ranging from 0.1 to 5 nM (R2 = 0.995), with a limit of detection of 0.258 nM in 10 mM phosphate buffer pH 7.4 containing human serum albumin. The performance of recovery (90.98-109.17%) and repeatability (coefficients of variation < 8.46%) obtained was also acceptable for quantitative determinations. The platform was employed for direct determination of hSAA1 concentrations in undiluted serum samples from lung cancer patients (relative standard deviation (RSD) < 7.46%) and healthy humans (RSD < 3.96%). The results were compared with those obtained using a commercially available enzyme-linked immunosorbent assay alongside liquid chromatography with tandem mass spectrometry measurements.
Collapse
|
4
|
Özmen EN, Kartal E, Turan MB, Yazıcıoğlu A, Niazi JH, Qureshi A. Graphene and carbon nanotubes interfaced electrochemical nanobiosensors for the detection of SARS-CoV-2 (COVID-19) and other respiratory viral infections: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112356. [PMID: 34579878 PMCID: PMC8339589 DOI: 10.1016/j.msec.2021.112356] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/24/2021] [Accepted: 08/02/2021] [Indexed: 01/15/2023]
Abstract
Recent COVID-19 pandemic has claimed millions of lives due to lack of a rapid diagnostic tool. Global scientific community is now making joint efforts on developing rapid and accurate diagnostic tools for early detection of viral infections to preventing future outbreaks. Conventional diagnostic methods for virus detection are expensive and time consuming. There is an immediate requirement for a sensitive, reliable, rapid and easy-to-use Point-of-Care (PoC) diagnostic technology. Electrochemical biosensors have the potential to fulfill these requirements, but they are less sensitive for sensing viruses/viral infections. However, sensitivity and performance of these electrochemical platforms can be improved by integrating carbon nanostructure, such as graphene and carbon nanotubes (CNTs). These nanostructures offer excellent electrical property, biocompatibility, chemical stability, mechanical strength and, large surface area that are most desired in developing PoC diagnostic tools for detecting viral infections with speed, sensitivity, and cost-effectiveness. This review summarizes recent advancements made toward integrating graphene/CNTs nanostructures and their surface modifications useful for developing new generation of electrochemical nanobiosensors for detecting viral infections. The review also provides prospects and considerations for extending the graphene/CNTs based electrochemical transducers into portable and wearable PoC tools that can be useful in preventing future outbreaks and pandemics.
Collapse
Affiliation(s)
- Emine Nur Özmen
- Department of Molecular Biology and Genetics, Boğaziçi University, Bebek, 34342 Istanbul, Turkey
| | - Enise Kartal
- Department of Mechanical Engineering, Bilkent University, Ankara, Turkey
| | - Mehmet Bora Turan
- Department of Mechanical Engineering, Bilkent University, Ankara, Turkey
| | - Alperen Yazıcıoğlu
- Faculty of Engineering and Natural Sciences, Sabanci University, Orta Mahalle 34956, Tuzla, Istanbul, Turkey
| | - Javed H Niazi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla 34956, Istanbul, Turkey.
| | - Anjum Qureshi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla 34956, Istanbul, Turkey.
| |
Collapse
|
5
|
Mikuła E. Recent Advancements in Electrochemical Biosensors for Alzheimer's Disease Biomarkers Detection. Curr Med Chem 2021; 28:4049-4073. [PMID: 33176635 PMCID: PMC8287894 DOI: 10.2174/0929867327666201111141341] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 09/28/2020] [Accepted: 10/07/2020] [Indexed: 02/06/2023]
Abstract
Background It is estimated that the average time between the diagnosis of Alzheimer’s disease (AD) and the patient’s death is 5-9 years. Therefore, both the initial phase of the disease and the preclinical state can be included in the critical period in disease diagnosis. Accordingly, huge progress has recently been observed in biomarker research to identify risk factors for dementia in older people with normal cognitive functions and mild cognitive impairments. Methods Electrochemical biosensors are excellent analytical tools that are used in the detection of AD biomarkers as they are easy to use, portable, and can do analysis in real time. Results This review presents the analytical techniques currently used to determine AD biomarkers in terms of their advantages and disadvantages; the most important clinical biomarkers of AD and their role in the disease. All recently used biorecognition molecules in electrochemical biosensor development, i.e., receptor protein, antibodies, aptamers and nucleic acids, are summarized for the first time. Novel electrochemical biosensors for AD biomarker detection, as ideal analytical platforms for point-of-care diagnostics, are also reviewed. Conclusion The article focuses on various strategies of biosensor chemical surface modifications to immobilize biorecognition molecules, enabling specific, quantitative AD biomarker detection in synthetic and clinical samples. In addition, this is the first review that presents innovative single-platform systems for simultaneous detection of multiple biomarkers and other important AD-associated biological species based on electrochemical techniques. The importance of these platforms in disease diagnosis is discussed.
Collapse
Affiliation(s)
- Edyta Mikuła
- Department of Biosensors, Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland
| |
Collapse
|
6
|
Maciel Braga LA, Mota FB. Early cancer diagnosis using lab-on-a-chip devices : A bibliometric and network analysis. COLLNET JOURNAL OF SCIENTOMETRICS AND INFORMATION MANAGEMENT 2021. [DOI: 10.1080/09737766.2021.1949949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Luiza Amara Maciel Braga
- Faculty of Economics, Fluminense Federal University, Prof. Marcos Waldemar de Freitas Reis Street, 24210-200, Brazil,
| | - Fabio Batista Mota
- Center for Strategic Studies, Oswaldo Cruz Foundation, Brasil Avenue 4036, 21040-361, Brazil
| |
Collapse
|
7
|
Ouyang M, Tu D, Tong L, Sarwar M, Bhimaraj A, Li C, Coté GL, Di Carlo D. A review of biosensor technologies for blood biomarkers toward monitoring cardiovascular diseases at the point-of-care. Biosens Bioelectron 2021; 171:112621. [PMID: 33120234 DOI: 10.1016/j.bios.2020.112621] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 09/06/2020] [Accepted: 09/14/2020] [Indexed: 01/03/2023]
Abstract
Cardiovascular diseases (CVDs) cause significant mortality globally. Notably, CVDs disproportionately negatively impact underserved populations, such as those that are economically disadvantaged and often located in remote regions. Devices to measure cardiac biomarkers have traditionally been focused on large instruments in a central laboratory but the development of affordable, portable devices that measure multiple cardiac biomarkers at the point-of-care (POC) are needed to improve clinical outcomes for patients, especially in underserved populations. Considering the enormity of the global CVD problem, complexity of CVDs, and the large candidate pool of biomarkers, it is of great interest to evaluate and compare biomarker performance and identify potential multiplexed panels that can be used in combination with affordable and robust biosensors at the POC toward improved patient care. This review focuses on describing the known and emerging CVD biosensing technologies for analysis of cardiac biomarkers from blood. Initially, the global burden of CVDs and the standard of care for the primary CVD categories, namely heart failure (HF) and acute coronary syndrome (ACS) including myocardial infarction (MI) are discussed. The latest United States, Canadian and European society guidelines recommended standalone, emerging, and add-on cardiac biomarkers, as well as their combinations are then described for the prognosis, diagnosis, and risk stratification of CVDs. Finally, both commercial in vitro biosensing devices and recent state-of-art techniques for detection of cardiac biomarkers are reviewed that leverage single and multiplexed panels of cardiac biomarkers with a view toward affordable, compact devices with excellent performance for POC diagnosis and monitoring.
Collapse
Affiliation(s)
- Mengxing Ouyang
- Department of Bioengineering, University of California, Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095, USA
| | - Dandan Tu
- Department of Biomedical Engineering, Texas A&M University, 400 Bizzell St, College Station, TX, 77843, USA
| | - Lin Tong
- Nanobioengineering/Bioelectronics Lab, Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, Miami, FL, 33174, USA
| | - Mehenur Sarwar
- Nanobioengineering/Bioelectronics Lab, Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, Miami, FL, 33174, USA
| | - Arvind Bhimaraj
- Department of Cardiology, Houston Methodist J.C. Walter Transplant Center, Houston Methodist Hospital, 6550 Fannin St., Houston, TX, 77030, USA
| | - Chenzhong Li
- Nanobioengineering/Bioelectronics Lab, Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, Miami, FL, 33174, USA.
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, 400 Bizzell St, College Station, TX, 77843, USA; Center for Remote Health Technologies & Systems, Texas A&M Engineering Experiment Station, 101 Bizzell St, College Station, TX, 77840, USA.
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095, USA.
| |
Collapse
|
8
|
Mandal N, Pakira V, Samanta N, Das N, Chakraborty S, Pramanick B, RoyChaudhuri C. PSA detection using label free graphene FET with coplanar electrodes based microfluidic point of care diagnostic device. Talanta 2021; 222:121581. [DOI: 10.1016/j.talanta.2020.121581] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/20/2020] [Accepted: 08/21/2020] [Indexed: 12/17/2022]
|
9
|
Highly sensitive vertical flow based point-of-care immunokit for rapid and early detection of human CRP as a cardiovascular risk factor. Biomed Microdevices 2020; 22:28. [DOI: 10.1007/s10544-020-00480-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|