1
|
Dias FM, Cardenas DAC, Toledo MAF, Oliveira FAC, Ribeiro E, Krieger JE, Gutierrez MA. Exploring the limitations of blood pressure estimation using the photoplethysmography signal. Physiol Meas 2025; 46:045007. [PMID: 40209759 DOI: 10.1088/1361-6579/adcb86] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2025] [Accepted: 04/10/2025] [Indexed: 04/12/2025]
Abstract
Objetive.Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) emerges as a promising approach for continuous BP monitoring. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, requiring a comprehensive evaluation of their efficacy. This paper aims to provide the potentials and limitations regarding BP estimation from single-site PPG signals.Approach.We developed a calibration-based Siamese ResNet model for BP estimation. We compared the use of normalized PPG (N-PPG) against the normalized invasive arterial BP (N-IABP) signals as input. N-IABP signals, while not directly presenting systolic (SBP) and diastolic (DBP) BP values, are expected to offer more precise estimations than PPG since it is a direct pressure sensor inside the body. Thus, if N-IABP poses challenges in BP estimation, predicting BP from PPG signals might be even more challenging.Main results.Our evaluation, conducted using the AAMI and BHS standards on the VitalDB dataset, revealed that inference using N-IABP signals meet with AAMI standards for both SBP and DBP, with errors of1.29±6.33mmHg for systolic pressure and1.17±5.78for diastolic pressure. In contrast, N-PPG based inference exhibited inferior performance than N-IABP, presenting1.49±11.82mmHg and0.89±7.27mmHg for systolic and diastolic pressure respectively in their best setup.Significance.Our findings establish a critical benchmark for PPG performance, providing realistic expectations for its BP estimation capabilities. We concluded that while PPG signals contain BP-correlated information, they may not suffice for accurate prediction.
Collapse
Affiliation(s)
- Felipe M Dias
- Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil
- Polytechnique School (POLI-USP), University of Sao Paulo, Brazil
| | - Diego A C Cardenas
- Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil
| | - Marcelo A F Toledo
- Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil
| | - Filipe A C Oliveira
- Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil
- Polytechnique School (POLI-USP), University of Sao Paulo, Brazil
| | - Estela Ribeiro
- Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil
| | - Jose E Krieger
- Heart Institute (InCor), Clinics Hospital University of Sao Paulo Medical School, Brazil
| | | |
Collapse
|
2
|
Min S, An J, Lee JH, Kim JH, Joe DJ, Eom SH, Yoo CD, Ahn HS, Hwang JY, Xu S, Rogers JA, Lee KJ. Wearable blood pressure sensors for cardiovascular monitoring and machine learning algorithms for blood pressure estimation. Nat Rev Cardiol 2025:10.1038/s41569-025-01127-0. [PMID: 39966649 DOI: 10.1038/s41569-025-01127-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/19/2025] [Indexed: 02/20/2025]
Abstract
With advances in materials science and medical technology, wearable sensors have become crucial tools for the early diagnosis and continuous monitoring of numerous cardiovascular diseases, including arrhythmias, hypertension and coronary artery disease. These devices employ various sensing mechanisms, such as mechanoelectric, optoelectronic, ultrasonic and electrophysiological methods, to measure vital biosignals, including pulse rate, blood pressure and changes in heart rhythm. In this Review, we provide a comprehensive overview of the current state of wearable cardiovascular sensors, focusing particularly on those that measure blood pressure. We explore biosignal sensing principles, discuss blood pressure estimation methods (including machine learning algorithms) and summarize the latest advances in cuffless wearable blood pressure sensors. Finally, we highlight the challenges of and offer insights into potential pathways for the practical application of cuffless wearable blood pressure sensors in the medical field from both technical and clinical perspectives.
Collapse
Affiliation(s)
- Seongwook Min
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Jaehun An
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Jae Hee Lee
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | - Ji Hoon Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Daniel J Joe
- Safety Measurement Institute, Korea Research Institute of Standards and Science (KRISS), Daejeon, Republic of Korea
| | - Soo Hwan Eom
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Chang D Yoo
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Hyo-Suk Ahn
- Department of Internal Medicine, Division of Cardiology, Uijeongbu St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jin-Young Hwang
- Department of Anaesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, College of Medicine, Seoul National University, Seoul, Republic of Korea
| | - Sheng Xu
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | - Keon Jae Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea.
| |
Collapse
|
3
|
Dasari A, Jeni LA, Tucker CS. Video-based estimation of blood pressure. PLoS One 2025; 20:e0311654. [PMID: 39883614 PMCID: PMC11781723 DOI: 10.1371/journal.pone.0311654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2024] [Accepted: 09/23/2024] [Indexed: 02/01/2025] Open
Abstract
In this work, we propose a non-contact video-based approach that estimates an individual's blood pressure. The estimation of blood pressure is critical for monitoring hypertension and cardiovascular diseases such as coronary artery disease or stroke. Estimation of blood pressure is typically achieved using contact-based devices which apply pressure on the arm through a cuff. Such contact-based devices are cost-prohibitive as well as limited in their scalability due to the requirement of specialized equipment. The ubiquity of mobile phones and video-based capturing devices motivates the development of a non-contact blood pressure estimation method-Video-based Blood Pressure Estimation (V-BPE). We leverage the time difference of the blood pulse arrival at two different locations in the body (Pulse Transit Time) and the inverse relation between the blood pressure and the velocity of blood pressure pulse propagation in the artery to analytically estimate the blood pressure. Through statistical hypothesis testing, we demonstrate that Pulse Transit Time-based approaches to estimate blood pressure require knowledge of subject specific blood vessel parameters, such as the length of the blood vessel. We utilize a combination of computer vision techniques and demographic information (such as the height and the weight of the subject) to capture and incorporate the aforementioned subject specific blood vessel parameters into our estimation of blood pressure. We demonstrate the robustness of V-BPE by evaluating the efficacy of blood pressure estimation in demographically diverse, outside-the-lab conditions. V-BPE is advantageous in three ways; 1) it is non-contact-based, reducing the possibility of infection due to contact 2) it is scalable, given the ubiquity of video recording devices and 3) it is robust to diverse demographic scenarios due to the incorporation of subject specific information.
Collapse
Affiliation(s)
- Ananyananda Dasari
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States of America
| | - Laszlo A. Jeni
- The Robotics Institute, Carnegie Mellon University, Pittsburgh, PA, United States of America
| | - Conrad S. Tucker
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States of America
- The Robotics Institute, Carnegie Mellon University, Pittsburgh, PA, United States of America
| |
Collapse
|
4
|
Lee S, Al-antari MA, Joshi GP. Improved Confidence-Interval Estimations Using Uncertainty Measure and Weighted Feature Decisions for Cuff-Less Blood-Pressure Measurements. Bioengineering (Basel) 2025; 12:131. [PMID: 40001651 PMCID: PMC11852306 DOI: 10.3390/bioengineering12020131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2024] [Revised: 01/24/2025] [Accepted: 01/24/2025] [Indexed: 02/27/2025] Open
Abstract
This paper presents a method to improve confidence-interval (CI) estimation using individual uncertainty measures and weighted feature decisions for cuff-less blood-pressure (BP) measurement. We obtained uncertainty using Gaussian process regression (GPR). The CI obtained from the GPR model is computed using the distribution of BP estimates, which provides relatively wide CIs. Thus, we proposed a method to obtain improved CIs for individual subjects by applying bootstrap and uncertainty methods using the cuff-less BP estimates of each subject obtained through GPR. This study also introduced a novel method to estimate cuff-less BP with high fidelity by determining highly weighted features using weighted feature decisions. The standard deviation of the proposed method's mean error is 2.94 mmHg and 1.50 mmHg for systolic blood pressure (SBP) and (DBP), respectively. The mean absolute error results were obtained by weighted feature determination combining GPR and gradient boosting algorithms (GBA) for SBP (1.46 mmHg) and DBP (0.69 mmHg). The study confirmed that the BP estimates were within the CI based on the test samples of almost all subjects. The weighted feature decisions combining GPR and GBA were more accurate and reliable for cuff-less BP estimation.
Collapse
Affiliation(s)
- Soojeong Lee
- Department of Computer Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea;
| | - Mugahed A. Al-antari
- Department of Artificial Intelligence and Data Science, Sejong University, Seoul 05006, Republic of Korea
| | - Gyanendra Prasad Joshi
- Department of AI Software, Kangwon National University, Kangwon State, Samcheok 10587, Republic of Korea
| |
Collapse
|
5
|
Chen J, Zhou X, Feng L, Ling BWK, Han L, Zhang H. rU-Net, Multi-Scale Feature Fusion and Transfer Learning: Unlocking the Potential of Cuffless Blood Pressure Monitoring With PPG and ECG. IEEE J Biomed Health Inform 2025; 29:166-176. [PMID: 39423074 DOI: 10.1109/jbhi.2024.3483301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2024]
Abstract
This study introduces an innovative deep-learning model for cuffless blood pressure estimation using PPG and ECG signals, demonstrating state-of-the-art performance on the largest clean dataset, PulseDB. The rU-Net architecture, a fusion of U-Net and ResNet, enhances both generalization and feature extraction accuracy. Accurate multi-scale feature capture is facilitated by short-time Fourier transform (STFT) time-frequency distributions and multi-head attention mechanisms, allowing data-driven feature selection. The inclusion of demographic parameters as supervisory information further elevates performance. On the calibration-based dataset, our model excels, achieving outstanding accuracy (SBP MAE ± std: 4.49 ± 4.86 mmHg, DBP MAE ± std: 2.69 ± 3.10 mmHg), surpassing AAMI standards and earning a BHS Grade A rating. Addressing the challenge of calibration-free data, we propose a fine-tuning-based transfer learning approach. Remarkably, with only 10% data transfer, our model attains exceptional accuracy (SBP MAE ± std: 4.14 ± 5.01 mmHg, DBP MAE ± std: 2.48 ± 2.93 mmHg). This study sets the stage for the development of highly accurate and reliable wearable cuffless blood pressure monitoring devices.
Collapse
|
6
|
Raju SMTU, Dipto SA, Hossain MI, Chowdhury MAS, Haque F, Nashrah AT, Nishan A, Khan MMH, Hashem MMA. DNN-BP: a novel framework for cuffless blood pressure measurement from optimal PPG features using deep learning model. Med Biol Eng Comput 2024; 62:3687-3708. [PMID: 38963467 DOI: 10.1007/s11517-024-03157-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 06/10/2024] [Indexed: 07/05/2024]
Abstract
Continuous blood pressure (BP) provides essential information for monitoring one's health condition. However, BP is currently monitored using uncomfortable cuff-based devices, which does not support continuous BP monitoring. This paper aims to introduce a blood pressure monitoring algorithm based on only photoplethysmography (PPG) signals using the deep neural network (DNN). The PPG signals are obtained from 125 unique subjects with 218 records and filtered using signal processing algorithms to reduce the effects of noise, such as baseline wandering, and motion artifacts. The proposed algorithm is based on pulse wave analysis of PPG signals, extracted various domain features from PPG signals, and mapped them to BP values. Four feature selection methods are applied and yielded four feature subsets. Therefore, an ensemble feature selection technique is proposed to obtain the optimal feature set based on major voting scores from four feature subsets. DNN models, along with the ensemble feature selection technique, outperformed in estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) compared to previously reported approaches that rely only on the PPG signal. The coefficient of determination ( R 2 ) and mean absolute error (MAE) of the proposed algorithm are 0.962 and 2.480 mmHg, respectively, for SBP and 0.955 and 1.499 mmHg, respectively, for DBP. The proposed approach meets the Advancement of Medical Instrumentation standard for SBP and DBP estimations. Additionally, according to the British Hypertension Society standard, the results attained Grade A for both SBP and DBP estimations. It concludes that BP can be estimated more accurately using the optimal feature set and DNN models. The proposed algorithm has the potential ability to facilitate mobile healthcare devices to monitor continuous BP.
Collapse
Affiliation(s)
- S M Taslim Uddin Raju
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh.
| | - Safin Ahmed Dipto
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| | - Md Imran Hossain
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| | - Md Abu Shahid Chowdhury
- Department of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| | - Fabliha Haque
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| | - Ayesha Tun Nashrah
- Department of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| | - Araf Nishan
- Department of Business Administration, International American University, Los Angeles, CA, 90010, USA
| | - Md Mahamudul Hasan Khan
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| | - M M A Hashem
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
| |
Collapse
|
7
|
Cheung MY, Sabharwal A, Cote GL, Veeraraghavan A. Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation. IEEE Trans Biomed Eng 2024; 71:3569-3592. [PMID: 39106139 PMCID: PMC11799359 DOI: 10.1109/tbme.2024.3434344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2024]
Abstract
OBJECTIVE Rapid advances in cuffless blood pressure (BP) monitoring have the potential to radically transform clinical care for cardiovascular health. However, due to the large heterogeneity in device design and evaluation, it is difficult to critically and quantitatively evaluate research progress. In this two-part manuscript, we provide a principled way of describing and accounting for heterogeneity in device and study design. METHODS We first provide an overview of foundational elements and design principles of three critical aspects: 1) sensors and systems, 2) pre-processing and feature extraction, and 3) BP estimation algorithms. Then, we critically analyze the state-of-the-art methods via a systematic review. RESULTS First, we find large heterogeneity in study designs, making fair comparisons extremely challenging. Moreover, many study designs have data leakage and are underpowered. We suggest a first open-contribution BP estimation benchmark for standardization. Next, we observe that BP distribution in the study sample and the time between calibration and test in emerging personalized devices confound BP estimation error. We suggest accounting for these using a convenient metric coined "explained deviation". Finally, we complement this manuscript with a website, https://wearablebp.github.io, containing a bibliography, meta-analysis results, datasets, and benchmarks, providing a timely plaWorm to understand state-of-the-art devices. CONCLUSION There is large heterogeneity in device and study design, which should be carefully accounted for when designing, comparing, and contrasting studies. SIGNIFICANCE Our findings will allow readers to parse out the heterogeneous literature and move toward promising directions for safer and more reliable devices in clinical practice and beyond.
Collapse
|
8
|
Henry B, Merz M, Hoang H, Abdulkarim G, Wosik J, Schoettker P. Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits. Blood Press 2024; 33:2304190. [PMID: 38245864 DOI: 10.1080/08037051.2024.2304190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 01/07/2024] [Indexed: 01/22/2024]
Abstract
Background: Cuffless blood pressure measurement technologies have attracted significant attention for their potential to transform cardiovascular monitoring.Methods: This updated narrative review thoroughly examines the challenges, opportunities, and limitations associated with the implementation of cuffless blood pressure monitoring systems.Results: Diverse technologies, including photoplethysmography, tonometry, and ECG analysis, enable cuffless blood pressure measurement and are integrated into devices like smartphones and smartwatches. Signal processing emerges as a critical aspect, dictating the accuracy and reliability of readings. Despite its potential, the integration of cuffless technologies into clinical practice faces obstacles, including the need to address concerns related to accuracy, calibration, and standardization across diverse devices and patient populations. The development of robust algorithms to mitigate artifacts and environmental disturbances is essential for extracting clear physiological signals. Based on extensive research, this review emphasizes the necessity for standardized protocols, validation studies, and regulatory frameworks to ensure the reliability and safety of cuffless blood pressure monitoring devices and their implementation in mainstream medical practice. Interdisciplinary collaborations between engineers, clinicians, and regulatory bodies are crucial to address technical, clinical, and regulatory complexities during implementation. In conclusion, while cuffless blood pressure monitoring holds immense potential to transform cardiovascular care. The resolution of existing challenges and the establishment of rigorous standards are imperative for its seamless incorporation into routine clinical practice.Conclusion: The emergence of these new technologies shifts the paradigm of cardiovascular health management, presenting a new possibility for non-invasive continuous and dynamic monitoring. The concept of cuffless blood pressure measurement is viable and more finely tuned devices are expected to enter the market, which could redefine our understanding of blood pressure and hypertension.
Collapse
Affiliation(s)
- Benoit Henry
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Maxime Merz
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Harry Hoang
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ghaith Abdulkarim
- Neuro-Informatics Laboratory, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | - Jedrek Wosik
- Department of Medicine, Duke University School of Medicine, Durham, North Carolina
| | - Patrick Schoettker
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
9
|
Liu Q, Yang C, Yang S, Kwong CF, Wang J, Zhou N. Photoplethysmography-based non-invasive blood pressure monitoring via ensemble model and imbalanced dataset processing. Phys Eng Sci Med 2024; 47:1307-1321. [PMID: 39080206 PMCID: PMC11666703 DOI: 10.1007/s13246-024-01445-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 05/17/2024] [Indexed: 12/25/2024]
Abstract
Photoplethysmography, a widely embraced tool for non-invasive blood pressure (BP) monitoring, has demonstrated potential in BP prediction, especially when machine learning techniques are involved. However, predictions with a singular model often fall short in terms of accuracy. In order to counter this issue, we propose an innovative ensemble model that utilizes Light Gradient Boosting Machine (LightGBM) as the base estimator for predicting systolic and diastolic BP. This study included 115 women and 104 men, with experimental results indicating mean absolute errors of 5.63 mmHg and 9.36 mmHg for diastolic and systolic BP, in line with level B and C standards set by the British Hypertension Society. Additionally, our research confronts data imbalance in medical research which can detrimentally affect classification. Here we demonstrate an effective use for the Synthetic Minority Over-sampling Technique (SMOTE) with three nearest neighbors for handling moderate imbalanced datasets. The application of this method outperformed other methods in the field, achieving an F1 score of 81.6% and an AUC value of 0.895, emphasizing the potential value of SMOTE for addressing imbalanced datasets in medical research.
Collapse
Affiliation(s)
- Qianyu Liu
- School of Information Science and Engineering, NingboTech University, Ningbo, China
| | - Chaojie Yang
- Department of Electrical and Electronic Engineering, University of Nottingham Ningbo, Ningbo, China.
- Department of Electrical and Electronic Engineering, University of Nottingham, Nottingham, UK.
| | - Sen Yang
- Department of Electrical and Electronic Engineering, University of Nottingham Ningbo, Ningbo, China
- Next Generation Internet of Everything (NGIoE) Laboratory, University of Nottingham Ningbo, Ningbo, China
| | - Chiew Foong Kwong
- Department of Electrical and Electronic Engineering, University of Nottingham Ningbo, Ningbo, China
- Next Generation Internet of Everything (NGIoE) Laboratory, University of Nottingham Ningbo, Ningbo, China
| | - Jing Wang
- Department of Electrical and Electronic Engineering, University of Nottingham Ningbo, Ningbo, China
| | - Ning Zhou
- School of Civil Engineering and Architecture, NingboTech University, Ningbo, China
| |
Collapse
|
10
|
Callejas Pastor CA, Oh C, Hong B, Ku Y. Machine Learning-Based Cardiac Output Estimation Using Photoplethysmography in Off-Pump Coronary Artery Bypass Surgery. J Clin Med 2024; 13:7145. [PMID: 39685605 DOI: 10.3390/jcm13237145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 11/06/2024] [Accepted: 11/22/2024] [Indexed: 12/18/2024] Open
Abstract
Background/Objectives: Hemodynamic monitoring is crucial for managing critically ill patients and those undergoing major surgeries. Cardiac output (CO) is an essential marker for diagnosing hemodynamic deterioration and guiding interventions. The gold standard thermodilution method for measuring CO is invasive, prompting a search for non-invasive alternatives. This pilot study aimed to develop a non-invasive algorithm for classifying the cardiac index (CI) into low and non-low categories using finger photoplethysmography (PPG) and a machine learning model. Methods: PPG and continuous thermodilution CO data were collected from patients undergoing off-pump coronary artery bypass graft surgery. The dataset underwent preprocessing, and features were extracted and selected using the Relief algorithm. A CatBoost machine learning model was trained and evaluated using a validation and testing phase approach. Results: The developed model achieved an accuracy of 89.42% in the validation phase and 87.57% in the testing phase. Performance was balanced across low and non-low CO categories, demonstrating robust classification capabilities. Conclusions: This study demonstrates the potential of machine learning and non-invasive PPG for accurate CO classification. The proposed method could enhance patient safety and comfort in critical care and surgical settings by providing a non-invasive alternative to traditional invasive CO monitoring techniques. Further research is needed to validate these findings in larger, diverse patient populations and clinical scenarios.
Collapse
Affiliation(s)
- Cecilia A Callejas Pastor
- Research Institute for Medical Sciences, Chungnam National University College of Medicine, Daejeon 35015, Republic of Korea
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul 03080, Republic of Korea
| | - Chahyun Oh
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon 35015, Republic of Korea
| | - Boohwi Hong
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon 35015, Republic of Korea
| | - Yunseo Ku
- Department of Biomedical Engineering, Chungnam National University College of Medicine, Daejeon 35015, Republic of Korea
- Medical Device Research Center, Department of Biomedical Research Institute, Chungnam National University Hospital, Daejeon 35015, Republic of Korea
| |
Collapse
|
11
|
Tang Q, Tao C, Li X, Hu H, Chu X, Liu S, Zhang L, Su B, Xu J, An H. Data-knowledge co-driven feature based prediction model via photoplethysmography for evaluating blood pressure. Comput Biol Med 2024; 181:109076. [PMID: 39216405 DOI: 10.1016/j.compbiomed.2024.109076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/01/2024] [Accepted: 08/23/2024] [Indexed: 09/04/2024]
Abstract
BACKGROUND Knowledge feature (KF) with clear physiological significance of photoplethysmography are widely used in predicting blood pressure. However, KF primarily focus on local information of photoplethysmography, which may struggle to capture the overall characteristics. METHODS Firstly, functional data analysis (FDA) was introduced to extract two types of data feature (DF). Furthermore, data-knowledge co-driven feature (DKCF) was proposed by combining FDA and constraints of KF. Finally, random forest, ada boost, gradient boosting, support vector machine and deep neural network were adopted, to compare the abilities of KF, DFs and DKCF in predicting blood pressure with two datasets (A published dataset and a self-collected dataset). RESULTS Under the premise of extracting only 9 features, the average mean absolute errors (MAE) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) obtained by DKCF are both the smallest in dataset 1. In dataset 2, DKCF acquires the smallest MAE in predicting SBP and obtains the second smallest MAE in predicting DBP. CONCLUSIONS The results demonstrate that low-dimensional DKCF of photoplethysmography is closely correlated with blood pressure, which may serve as an important indicator for health assessment.
Collapse
Affiliation(s)
- Qingfeng Tang
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China; School of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| | - Chao Tao
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China.
| | - Xin Li
- School of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| | - Huihui Hu
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China.
| | - Xiaoyu Chu
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China.
| | - Shiping Liu
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China.
| | - Liangliang Zhang
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China.
| | - Benyue Su
- Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China; School of Mathematics and Computer Science, Tongling University, Tongling 244061, China.
| | - Jiatuo Xu
- School of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| | - Hui An
- Health Management & Physical Examination Center, Xiangyang Central Hospital, Affiliated Hospital of Hubei University of Arts and Science, Xiangyang 441021, China.
| |
Collapse
|
12
|
Fu X, Cheng W, Wan G, Yang Z, Tee BCK. Toward an AI Era: Advances in Electronic Skins. Chem Rev 2024; 124:9899-9948. [PMID: 39198214 PMCID: PMC11397144 DOI: 10.1021/acs.chemrev.4c00049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2024]
Abstract
Electronic skins (e-skins) have seen intense research and rapid development in the past two decades. To mimic the capabilities of human skin, a multitude of flexible/stretchable sensors that detect physiological and environmental signals have been designed and integrated into functional systems. Recently, researchers have increasingly deployed machine learning and other artificial intelligence (AI) technologies to mimic the human neural system for the processing and analysis of sensory data collected by e-skins. Integrating AI has the potential to enable advanced applications in robotics, healthcare, and human-machine interfaces but also presents challenges such as data diversity and AI model robustness. In this review, we first summarize the functions and features of e-skins, followed by feature extraction of sensory data and different AI models. Next, we discuss the utilization of AI in the design of e-skin sensors and address the key topic of AI implementation in data processing and analysis of e-skins to accomplish a range of different tasks. Subsequently, we explore hardware-layer in-skin intelligence before concluding with an analysis of the challenges and opportunities in the various aspects of AI-enabled e-skins.
Collapse
Affiliation(s)
- Xuemei Fu
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore
- Institute for Health Innovation & Technology, National University of Singapore, Singapore 119276, Singapore
| | - Wen Cheng
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore
- Institute for Health Innovation & Technology, National University of Singapore, Singapore 119276, Singapore
- The N.1 Institute for Health, National University of Singapore, Singapore 117456, Singapore
| | - Guanxiang Wan
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore
- Institute for Health Innovation & Technology, National University of Singapore, Singapore 119276, Singapore
| | - Zijie Yang
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore
- Institute for Health Innovation & Technology, National University of Singapore, Singapore 119276, Singapore
| | - Benjamin C K Tee
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore
- Institute for Health Innovation & Technology, National University of Singapore, Singapore 119276, Singapore
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583, Singapore
- The N.1 Institute for Health, National University of Singapore, Singapore 117456, Singapore
- Institute of Materials Research and Engineering, Agency for Science Technology and Research, Singapore 138634, Singapore
| |
Collapse
|
13
|
Mi J, Feng T, Wang H, Pei Z, Tang H. Beat-by-Beat Estimation of Hemodynamic Parameters in Left Ventricle Based on Phonocardiogram and Photoplethysmography Signals Using a Deep Learning Model: Preliminary Study. Bioengineering (Basel) 2024; 11:842. [PMID: 39199800 PMCID: PMC11351883 DOI: 10.3390/bioengineering11080842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/26/2024] [Accepted: 07/30/2024] [Indexed: 09/01/2024] Open
Abstract
Beat-by-beat monitoring of hemodynamic parameters in the left ventricle contributes to the early diagnosis and treatment of heart failure, valvular heart disease, and other cardiovascular diseases. Current accurate measurement methods for ventricular hemodynamic parameters are inconvenient for monitoring hemodynamic indexes in daily life. The objective of this study is to propose a method for estimating intraventricular hemodynamic parameters in a beat-to-beat style based on non-invasive PCG (phonocardiogram) and PPG (photoplethysmography) signals. Three beagle dogs were used as subjects. PCG, PPG, electrocardiogram (ECG), and invasive blood pressure signals in the left ventricle were synchronously collected while epinephrine medicine was injected into the veins to produce hemodynamic variations. Various doses of epinephrine were used to produce hemodynamic variations. A total of 40 records (over 12,000 cardiac cycles) were obtained. A deep neural network was built to simultaneously estimate four hemodynamic parameters of one cardiac cycle by inputting the PCGs and PPGs of the cardiac cycle. The outputs of the network were four hemodynamic parameters: left ventricular systolic blood pressure (SBP), left ventricular diastolic blood pressure (DBP), maximum rate of left ventricular pressure rise (MRR), and maximum rate of left ventricular pressure decline (MRD). The model built in this study consisted of a residual convolutional module and a bidirectional recurrent neural network module which learnt the local features and context relations, respectively. The training mode of the network followed a regression model, and the loss function was set as mean square error. When the network was trained and tested on one subject using a five-fold validation scheme, the performances were very good. The average correlation coefficients (CCs) between the estimated values and measured values were generally greater than 0.90 for SBP, DBP, MRR, and MRD. However, when the network was trained with one subject's data and tested with another subject's data, the performance degraded somewhat. The average CCs reduced from over 0.9 to 0.7 for SBP, DBP, and MRD; however, MRR had higher consistency, with the average CC reducing from over 0.9 to about 0.85 only. The generalizability across subjects could be improved if individual differences were considered. The performance indicates the possibility that hemodynamic parameters could be estimated by PCG and PPG signals collected on the body surface. With the rapid development of wearable devices, it has up-and-coming applications for self-monitoring in home healthcare environments.
Collapse
Affiliation(s)
- Jiachen Mi
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (J.M.); (T.F.); (H.W.)
| | - Tengfei Feng
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (J.M.); (T.F.); (H.W.)
| | - Hongkai Wang
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (J.M.); (T.F.); (H.W.)
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, China
- Dalian Key Laboratory of Digital Medicine for Critical Diseases, Dalian 116024, China
| | - Zuowei Pei
- Department of Cardiology, Central Hospital of Dalian University of Technology, No.826 Xinan Road, Dalian 116033, China;
| | - Hong Tang
- School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China; (J.M.); (T.F.); (H.W.)
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, China
- Dalian Key Laboratory of Digital Medicine for Critical Diseases, Dalian 116024, China
| |
Collapse
|
14
|
Qiu Y, Ma X, Li X, Fan S, Deng Z, Huang X. Non-Contact Blood Pressure Estimation From Radar Signals by a Stacked Deformable Convolution Network. IEEE J Biomed Health Inform 2024; 28:4553-4564. [PMID: 38743528 DOI: 10.1109/jbhi.2024.3400961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
This study introduces a contactless blood pressure monitoring approach that combines conventional radar signal processing with novel deep learning architectures. During the preprocessing phase, datasets suitable for synchronization are created by integrating Kalman filtering, multiscale bandpass filters, and a periodic extraction method in the time domain. These data comprise data on chest micro variations, encapsulating a complex array of physiological and biomedical information reflective of cardiac micromotions. The Radar-based Stacked Deformable convolution Network (RSD-Net) integrates channel and spatial self attention mechanisms within a deformable convolutional framework to enhance feature extraction from radar signals. The network architecture systematically employs deformable convolutions for initial deep feature extraction from individual signals. Subsequently, continuous blood pressure estimation is conducted using self attention mechanisms on feature map from single source coupled with multi-feature map channel attention. The performance of model is corroborated via the open-source dataset procured using a non-invasive 24 GHz six-port continuous wave radar system. The dataset, encompassing readings from 30 healthy individuals subjected to diverse conditions including rest, the Valsalva maneuver, apnea, and tilt-table examinations. It serves to substantiate the validity and resilience of the proposed method in the non-contact assessment of continuous blood pressure. Evaluation metrics reveal Pearson correlation coefficients of 0.838 for systolic and 0.797 for diastolic blood pressure predictions. The Mean Error (ME) and Standard Deviation (SD) for systolic and diastolic blood pressure measurements are -0.32 ±6.14 mmHg and -0.20 ±5.50 mmHg, respectively. The ablation study assesses the contribution of different structural components of the RSD-Net, validating their significance in the overall of model performance.
Collapse
|
15
|
Li J, Chu H, Chen Z, Yiu CK, Qu Q, Li Z, Yu X. Recent Advances in Materials, Devices and Algorithms Toward Wearable Continuous Blood Pressure Monitoring. ACS NANO 2024; 18:17407-17438. [PMID: 38923501 DOI: 10.1021/acsnano.4c04291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Continuous blood pressure (BP) tracking provides valuable insights into the health condition and functionality of the heart, arteries, and overall circulatory system of humans. The rapid development in flexible and wearable electronics has significantly accelerated the advancement of wearable BP monitoring technologies. However, several persistent challenges, including limited sensing capabilities and stability of flexible sensors, poor interfacial stability between sensors and skin, and low accuracy in BP estimation, have hindered the progress in wearable BP monitoring. To address these challenges, comprehensive innovations in materials design, device development, system optimization, and modeling have been pursued to improve the overall performance of wearable BP monitoring systems. In this review, we highlight the latest advancements in flexible and wearable systems toward continuous noninvasive BP tracking with a primary focus on materials development, device design, system integration, and theoretical algorithms. Existing challenges, potential solutions, and further research directions are also discussed to provide theoretical and technical guidance for the development of future wearable systems in continuous ambulatory BP measurement with enhanced sensing capability, robustness, and long-term accuracy.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Hongwei Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China
| | - Zhenlin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qing'ao Qu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zhiyuan Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
- Hong Kong Institute for Clean Energy, City University of Hong Kong, Kowloon, Hong Kong, China
| |
Collapse
|
16
|
Hou Z, Huang Y, Huang J, Lv Y, Zhao N, Lu H, Shan C, Wang W. Can Pulse Arrival Time be Used for Cuffless Blood Pressure Estimation? A Clinical Study in ICU. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039284 DOI: 10.1109/embc53108.2024.10781935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Clinical studies have shown that Pulse Arrival Time (PAT) is potentially related with blood pressure (BP), but the subcomponent of PAT, i.e. Pre-Ejection Period (PEP), affects the reliability of BP estimation, so it is questionable whether PAT can be used to estimate BP. In this paper, we collect clinical data from 12 patients in the Intensive Care Unit (ICU) and validate the question based on different feature sets and regression models. We first verified whether it is feasible to use PAT alone for BP estimation. Subsequently, we explore the feasibility of using auxiliary features, including the statistical features of PAT (maximum, minimum and standard deviation) and three vital signs (heart rate, respiratory rate, and perfusion index), to facilitate the BP regression. The hybrid feature set led to a significant reduction of errors in BP regression. As compared to PAT alone, the MAE obtained by the hybrid feature set is reduced 11.68 mmHg for SBP, 7.90 mmHg for DBP, and 7.58 mmHg for MBP. Our conclusion is that PAT itself alone is not appropriate for BP estimation, due to the negative impact of PEP. But the fusion with auxiliary features can somehow weaken the effect of PEP on BP calibration.
Collapse
|
17
|
Alam J, Khan MF, Khan MA, Singh R, Mundazeer M, Kumar P. A Systematic Approach Focused on Machine Learning Models for Exploring the Landscape of Physiological Measurement and Estimation Using Photoplethysmography (PPG). J Cardiovasc Transl Res 2024; 17:669-684. [PMID: 38010481 DOI: 10.1007/s12265-023-10462-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/08/2023] [Indexed: 11/29/2023]
Abstract
A non-invasive optical technique known as photoplethysmography (PPG) can be used to provide various physiological measurements and estimations. PPG can be used to assess cardiovascular disease (CVD). Hypertension is a primary risk factor for CVD and a major health problem worldwide. PPG is popular because of its important applications in the evaluation of cardiac activity, variations in venous blood volume, blood oxygen saturation, blood pressure and heart rate variability, etc. In this study, we provide a comprehensive analysis of the extraction of various physiological parameters using PPG waveforms. In addition, we focused on the role of machine learning (ML) models used for the estimation of blood pressure and hypertension classification based on PPG waveforms to make future research and innovation recommendations. This study will be helpful for researchers, scientists, and medical practitioners working on PPG waveforms for monitoring, screening, and diagnosis, as a comparative study or reference.
Collapse
Affiliation(s)
- Javed Alam
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates.
| | | | - Meraj Alam Khan
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates
- DigiBiomics Inc, Mississauga, Ontario, Canada
| | - Rinky Singh
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates
| | | | - Pramod Kumar
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates
| |
Collapse
|
18
|
Lai K, Wang X, Cao C. A Continuous Non-Invasive Blood Pressure Prediction Method Based on Deep Sparse Residual U-Net Combined with Improved Squeeze and Excitation Skip Connections. SENSORS (BASEL, SWITZERLAND) 2024; 24:2721. [PMID: 38732827 PMCID: PMC11086107 DOI: 10.3390/s24092721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 04/09/2024] [Accepted: 04/19/2024] [Indexed: 05/13/2024]
Abstract
Arterial blood pressure (ABP) serves as a pivotal clinical metric in cardiovascular health assessments, with the precise forecasting of continuous blood pressure assuming a critical role in both preventing and treating cardiovascular diseases. This study proposes a novel continuous non-invasive blood pressure prediction model, DSRUnet, based on deep sparse residual U-net combined with improved SE skip connections, which aim to enhance the accuracy of using photoplethysmography (PPG) signals for continuous blood pressure prediction. The model first introduces a sparse residual connection approach for path contraction and expansion, facilitating richer information fusion and feature expansion to better capture subtle variations in the original PPG signals, thereby enhancing the network's representational capacity and predictive performance and mitigating potential degradation in the network performance. Furthermore, an enhanced SE-GRU module was embedded in the skip connections to model and weight global information using an attention mechanism, capturing the temporal features of the PPG pulse signals through GRU layers to improve the quality of the transferred feature information and reduce redundant feature learning. Finally, a deep supervision mechanism was incorporated into the decoder module to guide the lower-level network to learn effective feature representations, alleviating the problem of gradient vanishing and facilitating effective training of the network. The proposed DSRUnet model was trained and tested on the publicly available UCI-BP dataset, with the average absolute errors for predicting systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) being 3.36 ± 6.61 mmHg, 2.35 ± 4.54 mmHg, and 2.21 ± 4.36 mmHg, respectively, meeting the standards set by the Association for the Advancement of Medical Instrumentation (AAMI), and achieving Grade A according to the British Hypertension Society (BHS) Standard for SBP and DBP predictions. Through ablation experiments and comparisons with other state-of-the-art methods, the effectiveness of DSRUnet in blood pressure prediction tasks, particularly for SBP, which generally yields poor prediction results, was significantly higher. The experimental results demonstrate that the DSRUnet model can accurately utilize PPG signals for real-time continuous blood pressure prediction and obtain high-quality and high-precision blood pressure prediction waveforms. Due to its non-invasiveness, continuity, and clinical relevance, the model may have significant implications for clinical applications in hospitals and research on wearable devices in daily life.
Collapse
Affiliation(s)
- Kaixuan Lai
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| | - Xusheng Wang
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| | - Congjun Cao
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| |
Collapse
|
19
|
Nishan A, M. Taslim Uddin Raju S, Hossain MI, Dipto SA, M. Tanvir Uddin S, Sijan A, Chowdhury MAS, Ahmad A, Mahamudul Hasan Khan M. A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms. Heliyon 2024; 10:e27779. [PMID: 38533045 PMCID: PMC10963242 DOI: 10.1016/j.heliyon.2024.e27779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/01/2024] [Accepted: 03/06/2024] [Indexed: 03/28/2024] Open
Abstract
Background and objective Hypertension is a potentially dangerous health condition that can be detected by measuring blood pressure (BP). Blood pressure monitoring and measurement are essential for preventing and treating cardiovascular diseases. Cuff-based devices, on the other hand, are uncomfortable and prevent continuous BP measurement. Methods In this study, a new non-invasive and cuff-less method for estimating Systolic Blood Pressure (SBP), Mean Arterial Pressure (MAP), and Diastolic Blood Pressure (DBP) has been proposed using characteristic features of photoplethysmogram (PPG) signals and nonlinear regression algorithms. PPG signals were collected from 219 participants, which were then subjected to preprocessing and feature extraction steps. Analyzing PPG and its derivative signals, a total of 46 time, frequency, and time-frequency domain features were extracted. In addition, the age and gender of each subject were also included as features. Further, correlation-based feature selection (CFS) and Relief F feature selection (ReliefF) techniques were used to select the relevant features and reduce the possibility of over-fitting the models. Finally, support vector regression (SVR), K-nearest neighbour regression (KNR), decision tree regression (DTR), and random forest regression (RFR) were established to develop the BP estimation model. Regression models were trained and evaluated on all features as well as selected features. The best regression models for SBP, MAP, and DBP estimations were selected separately. Results The SVR model, along with the ReliefF-based feature selection algorithm, outperforms other algorithms in estimating the SBP, MAP, and DBP with the mean absolute error of 2.49, 1.62 and 1.43 mmHg, respectively. The proposed method meets the Advancement of Medical Instrumentation standard for BP estimations. Based on the British Hypertension Society standard, the results also fall within Grade A for SBP, MAP, and DBP. Conclusion The findings show that the method can be used to estimate blood pressure non-invasively, without using a cuff or calibration, and only by utilizing the PPG signal characteristic features.
Collapse
Affiliation(s)
- Araf Nishan
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - S. M. Taslim Uddin Raju
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Md Imran Hossain
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Safin Ahmed Dipto
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - S. M. Tanvir Uddin
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur, Bangladesh
| | - Asif Sijan
- Department of Software Engineering, American International University, Dhaka, Bangladesh
| | - Md Abu Shahid Chowdhury
- Department of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Ashfaq Ahmad
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Md Mahamudul Hasan Khan
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| |
Collapse
|
20
|
Tang H, Ma G, Qiu L, Zheng L, Bao R, Liu J, Wang L. Blood Pressure Estimation Based on PPG and ECG Signals Using Knowledge Distillation. Cardiovasc Eng Technol 2024; 15:39-51. [PMID: 38191807 DOI: 10.1007/s13239-023-00695-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 10/31/2023] [Indexed: 01/10/2024]
Abstract
OBJECTIVE Easy access bio-signals are useful for alleviating the shortcomings and difficulties associated with cuff-based and invasive blood pressure (BP) measurement techniques. This study proposes a deep learning model, trained using knowledge distillation, based on photoplethysmographic (PPG) and electrocardiogram (ECG) signals to estimate systolic and diastolic blood pressures. METHODS The estimation model comprises convolutional layers followed by one bidirectional recurrent layer and attention layers. The training approach involves knowledge distillation, where a smaller model (student model) is trained by leveraging information from a larger model (teacher model). RESULTS The proposed multistage model was evaluated on 1205 subjects from Medical Information Mart for Intensive Care (MIMIC) III database using the Association for the Advancement of Medical Instrumentation (AAMI) and the standards of the British Hypertension Society (BHS). The results revealed that our model performance achieved grade A in estimating both systolic blood pressure (SBP) and diastolic blood pressure (DBP) and met the requirements of the AAMI standard. After training with knowledge distillation (KD), the model achieved a mean absolute error and standard deviation of 2.94 ± 5.61 mmHg for SBP and 2.02 ± 3.60 mmHg for DBP. CONCLUSION Our results demonstrate the benefits of the knowledge distillation training method in reducing the number of parameters and improving the predictive accuracy of the blood pressure regression model.
Collapse
Affiliation(s)
- Hui Tang
- School of Electronic and Information Engineering, Soochow University, Suzhou, 215006, China
| | - Gang Ma
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou, 215163, China
| | - Lishen Qiu
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou, 215163, China
| | - Lesong Zheng
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou, 215163, China
| | - Rui Bao
- School of Electronic and Information Engineering, Soochow University, Suzhou, 215006, China
| | - Jing Liu
- School of Electronic and Information Engineering, Soochow University, Suzhou, 215006, China
| | - Lirong Wang
- School of Electronic and Information Engineering, Soochow University, Suzhou, 215006, China.
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou, 215163, China.
| |
Collapse
|
21
|
Liu Z, Zhang Y, Zhou C. BiGRU-attention for Continuous blood pressure trends estimation through single channel PPG. Comput Biol Med 2024; 168:107795. [PMID: 38056206 DOI: 10.1016/j.compbiomed.2023.107795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/23/2023] [Accepted: 11/28/2023] [Indexed: 12/08/2023]
Abstract
BACKGROUND Physiological parameter monitoring based on photoplethysmography (PPG) detection has the advantage of fast, portable, and non-invasive. Changes in the morphology of the PPG waveform can reflect the effect of arterial elasticity changes on blood pressure (BP). However, machine learning models and non-recurrent neural network models typically ignore the time-dependency of continuous PPG data, leading to the decrease of accuracy or the increased calibration frequency. OBJECTIVE This paper proposes a BiGRU model with attention to estimate BP trends, which uses a single-channel PPG signal combined with demographic information to estimate continuous BP trends point-by-point and to discuss the impact of calibration cycle. METHODS This paper selects 15 typical subjects from two groups with/without cardiovascular disease (CVD) and evaluates the model performance. Regarding the calibration frequency problem, we set two modes of non-calibration and calibration to validate the results of blood pressure trends estimation. RESULTS In the calibration mode, the estimation errors (ME ± STD) of SBP for CVD/non-CVD groups are 0.91 ± 10.58 mmHg/0.17 ± 10.06 mmHg respectively, and DBP are 0.34 ± 5.28 mmHg/-0.19 ± 5.36 mmHg; in the non-calibration mode, the estimation errors of SBP for CVD/non-CVD groups are 0.27 ± 9.87 mmHg/-0.82 ± 9.92 mmHg respectively, and DBP are -0.63 ± 3.28 mmHg/0.80 ± 4.93 mmHg. CONCLUSIONS The results show that the proposed model has high accuracy in estimating BP levels, which is expected to achieve real-time, long-term continuous BP trends monitoring in wearable devices.
Collapse
Affiliation(s)
- Ziyi Liu
- Guangdong Transtek Medical Electronics Co., Ltd., Zhongshan, 52843, People's Republic of China
| | - Yiming Zhang
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, 310027, People's Republic of China
| | - Congcong Zhou
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, 310027, People's Republic of China; Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, National Engineering Research Center for Innovation and Application of Minimally Invasive Devices, 3 East Qingchun Road, Hangzhou, 310016, Zhejiang Province, People's Republic of China.
| |
Collapse
|
22
|
Cano J, Bertomeu-González V, Fácila L, Hornero F, Alcaraz R, Rieta JJ. Improved Hypertension Risk Assessment with Photoplethysmographic Recordings Combining Deep Learning and Calibration. Bioengineering (Basel) 2023; 10:1439. [PMID: 38136030 PMCID: PMC10741001 DOI: 10.3390/bioengineering10121439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/08/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023] Open
Abstract
Hypertension, a primary risk factor for various cardiovascular diseases, is a global health concern. Early identification and effective management of hypertensive individuals are vital for reducing associated health risks. This study explores the potential of deep learning (DL) techniques, specifically GoogLeNet, ResNet-18, and ResNet-50, for discriminating between normotensive (NTS) and hypertensive (HTS) individuals using photoplethysmographic (PPG) recordings. The research assesses the impact of calibration at different time intervals between measurements, considering intervals less than 1 h, 1-6 h, 6-24 h, and over 24 h. Results indicate that calibration is most effective when measurements are closely spaced, with an accuracy exceeding 90% in all the DL strategies tested. For calibration intervals below 1 h, ResNet-18 achieved the highest accuracy (93.32%), sensitivity (84.09%), specificity (97.30%), and F1-score (88.36%). As the time interval between calibration and test measurements increased, classification performance gradually declined. For intervals exceeding 6 h, accuracy dropped below 81% but with all models maintaining accuracy above 71% even for intervals above 24 h. This study provides valuable insights into the feasibility of using DL for hypertension risk assessment, particularly through PPG recordings. It demonstrates that closely spaced calibration measurements can lead to highly accurate classification, emphasizing the potential for real-time applications. These findings may pave the way for advanced, non-invasive, and continuous blood pressure monitoring methods that are both efficient and reliable.
Collapse
Affiliation(s)
- Jesús Cano
- BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain;
| | - Vicente Bertomeu-González
- Cardiovascular Research Group, Clinical Medicine Department, Miguel Hernández University, 03202 Alicante, Spain;
| | - Lorenzo Fácila
- Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain;
| | - Fernando Hornero
- Cardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain;
| | - Raúl Alcaraz
- Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain;
| | - José J. Rieta
- BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain;
| |
Collapse
|
23
|
Yao C, Sun T, Huang S, He M, Liang B, Shen Z, Huang X, Liu Z, Wang H, Liu F, Chen HJ, Xie X. Personalized Machine Learning-Coupled Nanopillar Triboelectric Pulse Sensor for Cuffless Blood Pressure Continuous Monitoring. ACS NANO 2023; 17:24242-24258. [PMID: 37983291 DOI: 10.1021/acsnano.3c09766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
A wearable system that can continuously track the fluctuation of blood pressure (BP) based on pulse signals is highly desirable for the treatments of cardiovascular diseases, yet the sensitivity, reliability, and accuracy remain challenging. Since the correlations of pulse waveforms to BP are highly individualized due to the diversity of the patients' physiological characteristics, wearable sensors based on universal designs and algorithms often fail to derive BP accurately when applied on individual patients. Herein, a wearable triboelectric pulse sensor based on a biomimetic nanopillar layer was developed and coupled with Personalized Machine Learning (ML) to provide accurate and continuous monitoring of BP. Flexible conductive nanopillars as the triboelectric layer were fabricated through soft lithography replication of a cicada wing, which could effectively enhance the sensor's output performance to detect weak signal characteristics of pulse waveform for BP derivation. The sensors were coupled with a personalized Partial Least-Squares Regression (PLSR) ML to derive unknown BP based on individual pulse characteristics with reasonable accuracy, avoiding the issue of individual variability that was encountered by General PLSR ML or formula algorithms. The cuffless and intelligent design endow this ML-sensor as a highly promising platform for the care and treatments of hypertensive patients.
Collapse
Affiliation(s)
- Chuanjie Yao
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Tiancheng Sun
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Shuang Huang
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Mengyi He
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Baoming Liang
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Zhiran Shen
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Xinshuo Huang
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Zhengjie Liu
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - HaoLin Wang
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Fanmao Liu
- The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-sen University, Guangzhou 510080, China
| | - Hui-Jiuan Chen
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Xi Xie
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| |
Collapse
|
24
|
Baker S, Yogavijayan T, Kandasamy Y. Towards Non-Invasive and Continuous Blood Pressure Monitoring in Neonatal Intensive Care Using Artificial Intelligence: A Narrative Review. Healthcare (Basel) 2023; 11:3107. [PMID: 38131997 PMCID: PMC10743031 DOI: 10.3390/healthcare11243107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 11/29/2023] [Accepted: 12/04/2023] [Indexed: 12/23/2023] Open
Abstract
Preterm birth is a live birth that occurs before 37 completed weeks of pregnancy. Approximately 11% of babies are born preterm annually worldwide. Blood pressure (BP) monitoring is essential for managing the haemodynamic stability of preterm infants and impacts outcomes. However, current methods have many limitations associated, including invasive measurement, inaccuracies, and infection risk. In this narrative review, we find that artificial intelligence (AI) is a promising tool for the continuous measurement of BP in a neonatal cohort, based on data obtained from non-invasive sensors. Our findings highlight key sensing technologies, AI techniques, and model assessment metrics for BP sensing in the neonatal cohort. Moreover, our findings show that non-invasive BP monitoring leveraging AI has shown promise in adult cohorts but has not been broadly explored for neonatal cohorts. We conclude that there is a significant research opportunity in developing an innovative approach to provide a non-invasive alternative to existing continuous BP monitoring methods, which has the potential to improve outcomes for premature babies.
Collapse
Affiliation(s)
- Stephanie Baker
- College of Science and Engineering, James Cook University, Cairns, QLD 4878, Australia
| | - Thiviya Yogavijayan
- College of Medicine and Dentistry, James Cook University, Townsville, QLD 4811, Australia;
| | - Yogavijayan Kandasamy
- Department of Neonatology, Townsville University Hospital, Townsville, QLD 4811, Australia;
| |
Collapse
|
25
|
Pankaj, Kumar A, Komaragiri R, Kumar M. Blood pressure estimation and classification using a reference signal-less photoplethysmography signal: a deep learning framework. Phys Eng Sci Med 2023; 46:1589-1605. [PMID: 37747644 DOI: 10.1007/s13246-023-01322-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 08/21/2023] [Indexed: 09/26/2023]
Abstract
The markers that help to predict th function of a cardiovascular system are hemodynamic parameters like blood pressure (BP), stroke volume, heart rate, and cardiac output. Continuous analysis of hemodynamic parameters such as BP can detect abnormalities earlier, preventing cardiovascular diseases (CVDs). However, sometimes due to motion artifacts, it becomes difficult to monitor the BP accurately and classify it. This work presents an optimized deep learning model having the capability to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP) and classify the BP stages simultaneously from the same network using only a single channel photoplethysmography (PPG) signal. The proposed model is designed by exploiting the deep learning framework of a convolutional neural network (CNN), exhibiting the inherent ability to extract features automatically. Moreover, the proposed framework utilizes the superlet transform method to transform a 1-D PPG signal into a 2-D super-resolution time-frequency (TF) spectrogram. A superlet transform separates the peaks related to true PPG signal components and motion artifacts components. Thus, the superlet provides a robust realtime approach to accurately estimating and classifying BP using a single PPG sensor signal and does not require additional ECG and PPG sensor signals for reference. Using a super-resolution spectrogram and CNN model makes the method profitable in motion artifact removal, feature selection, and extraction. Hence the proposed framework becomes less complex for deployment on wearable devices having limited battery resources. The performance of the proposed framework is demonstrated on the publicly available larger dataset MIMIC-III. This work obtained a mean absolute error (MAE) of 2.71 mmHg and 2.42 mmHg for SBP and DBP, respectively. The classification accuracy for the SBP prediction is about 96.79%, whereas it is 98.94% for DBP. From a motion artifact-affected PPG signal, SBP and DBP are estimated. Then the estimated BP is classified into three categories: normotension, prehypertension, and hypertension, and is compared with the state of art methods to show the effectiveness of the proposed optimized framework.
Collapse
Affiliation(s)
- Pankaj
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| | - Ashish Kumar
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
- School of Computer science engineering and technology, Bennett University, Greater Noida, India
| | - Rama Komaragiri
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| | - Manjeet Kumar
- Department of Electronics and Communication Engineering, Delhi Technological University, Delhi, India.
| |
Collapse
|
26
|
Pankaj, Kumar A, Kumar M, Komaragiri R. Optimized deep neural network models for blood pressure classification using Fourier analysis-based time-frequency spectrogram of photoplethysmography signal. Biomed Eng Lett 2023; 13:739-750. [PMID: 37872982 PMCID: PMC10590347 DOI: 10.1007/s13534-023-00296-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/28/2023] [Accepted: 06/09/2023] [Indexed: 10/25/2023] Open
Abstract
Appropriate blood pressure (BP) management through continuous monitoring and rapid diagnosis helps to take preventive care against cardiovascular diseases (CVD). As hypertension is one of the leading causes of CVDs, keeping hypertension under control by a timely screening of subjects becomes lifesaving. This work proposes estimating BP from motion artifact-affected photoplethysmography signals (PPG) by applying signal processing techniques in realtime. This paper proposes a deep neural network-based methodology to accurately classify PPG signals using a Fourier theory-based time-frequency (TF) spectrogram. This work uses the Fourier decomposition method (FDM) to transform a PPG signal into a TF spectrogram. In the proposed work, the last three layers of the pre-trained deep neural network, namely, GoogleNet, DenseNet, and AlexNet, are modified and then used to classify the PPG signal into normotension, pre-hypertension, and hypertension. The proposed framework is trained and tested using the MIMIC-III and PPG-BP databases using five-fold training and testing. Out of the three deep neural networks, the proposed framework with the DenseNet-201 network performs best, with a test accuracy of 96.5%. The proposed work uses FDM to compute the TF spectrogram to accurately separate the motion artifacts and noise components from a noise-corrupted PPG signal. Capturing more frequency components that contain more information from PPG signals makes the deep neural networks extract better and more meaningful features. Thus, training a deep neural network model with clean PPG signal features improves the generalized capability of a BP classification model when tested in realtime.
Collapse
Affiliation(s)
- Pankaj
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| | - Ashish Kumar
- School of Electronics Engineering, Vellore Institute of Technology, Chennai, Tamil Nadu India
| | - Manjeet Kumar
- Department of Electronics and Communication Engineering, Delhi Technological University, Delhi, India
| | - Rama Komaragiri
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| |
Collapse
|
27
|
Sarkar S, Ghosh A. Schrödinger spectrum based continuous cuff-less blood pressure estimation using clinically relevant features from PPG signal and its second derivative. Comput Biol Med 2023; 166:107558. [PMID: 37806054 DOI: 10.1016/j.compbiomed.2023.107558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 09/02/2023] [Accepted: 09/28/2023] [Indexed: 10/10/2023]
Abstract
The presented study estimates cuff-less blood pressure (BP) from photoplethysmography (PPG) signals using multiple machine-learning (ML) models and the semi-classical signal analysis (SCSA) technique. The study proposes a novel signal reconstruction algorithm, which optimizes the semi-classical constant of the SCSA approach and eliminates the trade-off between complexity and accuracy during signal reconstruction. It predicts BP values using regression algorithms by processing reconstructed PPG signals' spectral features, extracting clinically relevant PPG and its second derivative's (SDPPG) morphological features. The developed method was assessed using a virtual in-silico dataset with more than 4000 subjects and the Multi-Parameter Intelligent Monitoring in Intensive Care Units (MIMIC-II) dataset. Results showed that the method attained a mean absolute error (MAE) of 5.37 and 2.96 mmHg for systolic and diastolic BP, respectively, using the CatBoost algorithm. This approach met the Association for the Advancement of Medical Instrumentation's standard and achieved Grade A for all BP categories in the British Hypertension Society protocol. The proposed framework performs well even when applied to a combined clinically relevant database originating from MIMIC-III and the Queensland dataset. The proposed method's performance is further evaluated in a non-clinical setting with noisy and deformed PPG signals to validate the efficacy of the SCSA method. The noise stress tests further showed that the algorithm maintained its key feature detection, signal reconstruction capability, and estimation accuracy up to a 10 dB SNR ratio. The proposed cuff-less BP estimation technique has the potential to perform well in mobile healthcare devices due to its straightforward implementation approach.
Collapse
Affiliation(s)
- Sayan Sarkar
- Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong, China.
| | - Aayushman Ghosh
- Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, 11103, India; Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States
| |
Collapse
|
28
|
Vaseekaran M, Kaese S, Görlich D, Wiemer M, Samol A. WATCH-BPM-Comparison of a WATCH-Type Blood Pressure Monitor with a Conventional Ambulatory Blood Pressure Monitor and Auscultatory Sphygmomanometry. SENSORS (BASEL, SWITZERLAND) 2023; 23:8877. [PMID: 37960576 PMCID: PMC10650650 DOI: 10.3390/s23218877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 09/18/2023] [Accepted: 10/29/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry. METHODS Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) or multiple measurements during 24 h compared to a conventional ambulatory BP monitor on the upper arm (n = 50). The two BP monitoring devices were simultaneously worn on the same arm throughout the monitoring period. In a subgroup of 50 patients, single measurements were also performed with an additional infrared smart device. RESULTS The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both systole (0.765) and diastole (0.732). This is exactly how the ICC was calculated for the individual mean values calculated over the 24 h long-term measurement of the individual patients for both systole (0.880) and diastole (0.829). The ICC between the infrared device and the conventional method was "bad" for SBP (0.329) and DBP (0.025). Therefore, no further long-term measurements were performed with the infrared device. CONCLUSION The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data.
Collapse
Affiliation(s)
- Mathini Vaseekaran
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
| | - Sven Kaese
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
| | - Dennis Görlich
- Institute of Biostatistics and Clinical Research, University Münster, 48149 Muenster, Germany;
| | - Marcus Wiemer
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
| | - Alexander Samol
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
- Department of Cardiology and Angiology, St. Antonius-Hospital Gronau GmbH, Möllenweg 22, 48599 Gronau, Germany
| |
Collapse
|
29
|
Attivissimo F, D’Alessandro VI, De Palma L, Lanzolla AML, Di Nisio A. Non-Invasive Blood Pressure Sensing via Machine Learning. SENSORS (BASEL, SWITZERLAND) 2023; 23:8342. [PMID: 37837172 PMCID: PMC10574845 DOI: 10.3390/s23198342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/21/2023] [Accepted: 10/07/2023] [Indexed: 10/15/2023]
Abstract
In this paper, a machine learning (ML) approach to estimate blood pressure (BP) using photoplethysmography (PPG) is presented. The final aim of this paper was to develop ML methods for estimating blood pressure (BP) in a non-invasive way that is suitable in a telemedicine health-care monitoring context. The training of regression models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) was conducted using new extracted features from PPG signals processed using the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the interest was on the use of the most significant features obtained by the Minimum Redundancy Maximum Relevance (MRMR) selection algorithm to train eXtreme Gradient Boost (XGBoost) and Neural Network (NN) models. This aim was satisfactorily achieved by also comparing it with works in the literature; in fact, it was found that XGBoost models are more accurate than NN models in both systolic and diastolic blood pressure measurements, obtaining a Root Mean Square Error (RMSE) for SBP and DBP, respectively, of 5.67 mmHg and 3.95 mmHg. For SBP measurement, this result is an improvement compared to that reported in the literature. Furthermore, the trained XGBoost regression model fulfills the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) as well as grade A of the British Hypertension Society (BHS) standard.
Collapse
Affiliation(s)
| | | | | | - Anna Maria Lucia Lanzolla
- Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy; (F.A.); (V.I.D.); (L.D.P.); (A.D.N.)
| | | |
Collapse
|
30
|
Huang S, Gao Y, Hu Y, Shen F, Jin Z, Cho Y. Recent development of piezoelectric biosensors for physiological signal detection and machine learning assisted cardiovascular disease diagnosis. RSC Adv 2023; 13:29174-29194. [PMID: 37818271 PMCID: PMC10561672 DOI: 10.1039/d3ra05932d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 09/21/2023] [Indexed: 10/12/2023] Open
Abstract
As cardiovascular disease stands as a global primary cause of mortality, there has been an urgent need for continuous and real-time heart monitoring to effectively identify irregular heart rhythms and to offer timely patient alerts. However, conventional cardiac monitoring systems encounter challenges due to inflexible interfaces and discomfort during prolonged monitoring. In this review article, we address these issues by emphasizing the recent development of the flexible, wearable, and comfortable piezoelectric passive sensor assisted by machine learning technology for diagnosis. This innovative device not only harmonizes with the dynamic mechanical properties of human skin but also facilitates continuous and real-time collection of physiological signals. Addressing identified challenges and constraints, this review provides insights into recent advances in piezoelectric cardiac sensors, from devices to circuit systems. Furthermore, this review delves into the integration of machine learning technologies, showcasing their pivotal role in facilitating continuous and real-time assessment of cardiac status. The synergistic combination of flexible piezoelectric sensor design and machine learning holds substantial potential in automating the detection of cardiac irregularities with minimal human intervention. This transformative approach has the power to revolutionize patient care paradigms.
Collapse
Affiliation(s)
- Shunyao Huang
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Yujia Gao
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Yian Hu
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Fengyi Shen
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Zhangsiyuan Jin
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Yuljae Cho
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| |
Collapse
|
31
|
Wang L, Tian S, Zhu R. A new method of continuous blood pressure monitoring using multichannel sensing signals on the wrist. MICROSYSTEMS & NANOENGINEERING 2023; 9:117. [PMID: 37744263 PMCID: PMC10511443 DOI: 10.1038/s41378-023-00590-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 07/06/2023] [Accepted: 07/31/2023] [Indexed: 09/26/2023]
Abstract
Hypertension is a worldwide health problem and a primary risk factor for cardiovascular disease. Continuous monitoring of blood pressure has important clinical value for the early diagnosis and prevention of cardiovascular disease. However, existing technologies for wearable continuous blood pressure monitoring are usually inaccurate, rely on subject-specific calibration and have poor generalization across individuals, which limit their practical applications. Here, we report a new blood pressure measurement method and develop an associated wearable device to implement continuous blood pressure monitoring for new subjects. The wearable device detects cardiac output and pulse waveform features through dual photoplethysmography (PPG) sensors worn on the palmar and dorsal sides of the wrist, incorporating custom-made interface sensors to detect the wearing contact pressure and skin temperature. The detected multichannel signals are fused using a machine-learning algorithm to estimate continuous blood pressure in real time. This dual PPG sensing method effectively eliminates the personal differences in PPG signals caused by different people and different wearing conditions. The proposed wearable device enables continuous blood pressure monitoring with good generalizability across individuals and demonstrates promising potential in personal health care applications.
Collapse
Affiliation(s)
- Liangqi Wang
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, 100084 Beijing, China
| | - Shuo Tian
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, 100084 Beijing, China
| | - Rong Zhu
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, 100084 Beijing, China
| |
Collapse
|
32
|
Liu ZD, Li Y, Zhang YT, Zeng J, Chen ZX, Cui ZW, Liu JK, Miao F. Cuffless Blood Pressure Measurement Using Smartwatches: A Large-Scale Validation Study. IEEE J Biomed Health Inform 2023; 27:4216-4227. [PMID: 37204948 DOI: 10.1109/jbhi.2023.3278168] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
This study aimed to evaluate the performance of cuffless blood pressure (BP) measurement techniques in a large and diverse cohort of participants. We enrolled 3077 participants (aged 18-75, 65.16% women, 35.91% hypertensive participants) and conducted followed-up for approximately 1 month. Electrocardiogram, pulse pressure wave, and multiwavelength photoplethysmogram signals were simultaneously recorded using smartwatches; dual-observer auscultation systolic BP (SBP) and diastolic BP (DBP) reference measurements were also obtained. Pulse transit time, traditional machine learning (TML), and deep learning (DL) models were evaluated with calibration and calibration-free strategy. TML models were developed using ridge regression, support vector machine, adaptive boosting, and random forest; while DL models using convolutional and recurrent neural networks. The best-performing calibration-based model yielded estimation errors of 1.33 ± 6.43 mmHg for DBP and 2.31 ± 9.57 mmHg for SBP in the overall population, with reduced SBP estimation errors in normotensive (1.97 ± 7.85 mmHg) and young (0.24 ± 6.61 mmHg) subpopulations. The best-performing calibration-free model had estimation errors of -0.29 ± 8.78 mmHg for DBP and -0.71 ± 13.04 mmHg for SBP. We conclude that smartwatches are effective for measuring DBP for all participants and SBP for normotensive and younger participants with calibration; performance degrades significantly for heterogeneous populations including older and hypertensive participants. The availability of cuffless BP measurement without calibration is limited in routine settings. Our study provides a large-scale benchmark for emerging investigations on cuffless BP measurement, highlighting the need to explore additional signals or principles to enhance the accuracy in large-scale heterogeneous populations.
Collapse
|
33
|
Zhou Y, Tan Z, Liu Y, Cheng H. Fully convolutional neural network and PPG signal for arterial blood pressure waveform estimation. Physiol Meas 2023; 44:075007. [PMID: 37402386 DOI: 10.1088/1361-6579/ace414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 07/04/2023] [Indexed: 07/06/2023]
Abstract
Objective. The quality of the arterial blood pressure (ABP) waveform is crucial for predicting the value of blood pressure. The ABP waveform is predicted through experiments, and then Systolic blood pressure (SBP), Diastolic blood pressure, (DBP), and Mean arterial pressure (MAP) information are estimated from the ABP waveform.Approach. To ensure the quality of the predicted ABP waveform, this paper carefully designs the network structure, input signal, loss function, and structural parameters. A fully convolutional neural network (CNN) MultiResUNet3+ is used as the core architecture of ABP-MultiNet3+. In addition to performing Kalman filtering on the original photoplethysmogram (PPG) signal, its first-order derivative and second-order derivative signals are used as ABP-MultiNet3+ enter. The model's loss function uses a combination of mean absolute error (MAE) and means square error (MSE) loss to ensure that the predicted ABP waveform matches the reference waveform.Main results. The proposed ABP-MultiNet3+ model was tested on the public MIMIC II databases, MAE of MAP, DBP, and SBP was 1.88 mmHg, 3.11 mmHg, and 4.45 mmHg, respectively, indicating a small model error. It experiment fully meets the standards of the AAMI standard and obtains level A in the DBP and MAP prediction standard test under the BHS standard. For SBP prediction, it obtains level B in the BHS standard test. Although it does not reach level A, it has a certain improvement compared with the existing methods.Significance. The results show that this algorithm can achieve sleeveless blood pressure estimation, which may enable mobile medical devices to continuously monitor blood pressure and greatly reduce the harm caused by Cardiovascular disease (CVD).
Collapse
Affiliation(s)
- Yongan Zhou
- School of Electrical and Information Engineering, Beijing University of Civil Engineering and Architecture, Beijing, 100044, People's Republic of China
| | - Zhi Tan
- School of Electrical and Information Engineering, Beijing University of Civil Engineering and Architecture, Beijing, 100044, People's Republic of China
| | - Yuhong Liu
- College of Pulmonary & Critical Care Medicine, 8th Medical Center, Chinese PLA General Hospital, People's Republic of China
- Beijing IROT Key Laboratory, People's Republic of China
| | - Haibo Cheng
- Jiangsu Future Network Group Co., Ltd, People's Republic of China
| |
Collapse
|
34
|
Li J, Jia H, Zhou J, Huang X, Xu L, Jia S, Gao Z, Yao K, Li D, Zhang B, Liu Y, Huang Y, Hu Y, Zhao G, Xu Z, Li J, Yiu CK, Gao Y, Wu M, Jiao Y, Zhang Q, Tai X, Chan RH, Zhang Y, Ma X, Yu X. Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure. Nat Commun 2023; 14:5009. [PMID: 37591881 PMCID: PMC10435523 DOI: 10.1038/s41467-023-40763-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 08/07/2023] [Indexed: 08/19/2023] Open
Abstract
Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial for preventing and diagnosing hypertension related diseases. However, current continuous BP monitoring instruments suffer from either bulky systems or poor user-device interfacial performance, hampering their applications in continuous BP monitoring. Here, we report a thin, soft, miniaturized system (TSMS) that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method, to allow real wearable, continuous wireless monitoring of ambulatory artery BP. By optimizing the materials selection, control/sampling strategy, and system integration, the TSMS exhibits improved interfacial performance while maintaining Grade A level measurement accuracy. Initial trials on 87 volunteers and clinical tracking of two hypertension individuals prove the capability of the TSMS as a reliable BP measurement product, and its feasibility and practical usability in precise BP control and personalized diagnosis schemes development.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Huiling Jia
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Jingkun Zhou
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Xingcan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Long Xu
- School of Mechanical and Aerospace Engineering, Jilin University, 130012, Changchun, China
| | - Shengxin Jia
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Zhan Gao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Kuanming Yao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Dengfeng Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Binbin Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yiming Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Ya Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yue Hu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Guangyao Zhao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zitong Xu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Jiyu Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuyu Gao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Mengge Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), 610054, Chengdu, China
| | - Yanli Jiao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qiang Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xuecheng Tai
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- Department of Mathematics, Hong Kong Baptist University, Hong Kong, China
| | - Raymond H Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuanting Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Xiaohui Ma
- Department of vascular and endovascular surgery, The first medical center of Chinese PLA General Hospital, 100853, Beijing, China.
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.
- City University of Hong Kong Shenzhen Research Institute, 518057, Shenzhen, China.
| |
Collapse
|
35
|
Chu Y, Tang K, Hsu YC, Huang T, Wang D, Li W, Savitz SI, Jiang X, Shams S. Non-invasive arterial blood pressure measurement and SpO 2 estimation using PPG signal: a deep learning framework. BMC Med Inform Decis Mak 2023; 23:131. [PMID: 37480040 PMCID: PMC10362790 DOI: 10.1186/s12911-023-02215-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 06/22/2023] [Indexed: 07/23/2023] Open
Abstract
BACKGROUND Monitoring blood pressure and peripheral capillary oxygen saturation plays a crucial role in healthcare management for patients with chronic diseases, especially hypertension and vascular disease. However, current blood pressure measurement methods have intrinsic limitations; for instance, arterial blood pressure is measured by inserting a catheter in the artery causing discomfort and infection. METHOD Photoplethysmogram (PPG) signals can be collected via non-invasive devices, and therefore have stimulated researchers' interest in exploring blood pressure estimation using machine learning and PPG signals as a non-invasive alternative. In this paper, we propose a Transformer-based deep learning architecture that utilizes PPG signals to conduct a personalized estimation of arterial systolic blood pressure, arterial diastolic blood pressure, and oxygen saturation. RESULTS The proposed method was evaluated with a subset of 1,732 subjects from the publicly available ICU dataset MIMIC III. The mean absolute error is 2.52 ± 2.43 mmHg for systolic blood pressure, 1.37 ± 1.89 mmHg for diastolic blood pressure, and 0.58 ± 0.79% for oxygen saturation, which satisfies the requirements of the Association of Advancement of Medical Instrumentation standard and achieve grades A for the British Hypertension Society standard. CONCLUSIONS The results indicate that our model meets clinical standards and could potentially boost the accuracy of blood pressure and oxygen saturation measurement to deliver high-quality healthcare.
Collapse
Affiliation(s)
- Yan Chu
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Kaichen Tang
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Yu-Chun Hsu
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Tongtong Huang
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Dulin Wang
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Wentao Li
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Sean I Savitz
- Institute for Stroke and Cerebrovascular Disease, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Xiaoqian Jiang
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA
- Institute for Stroke and Cerebrovascular Disease, University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Shayan Shams
- McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, TX, USA.
- Institute for Stroke and Cerebrovascular Disease, University of Texas Health Science Center at Houston, Houston, TX, USA.
- Department of Applied Data Science, San Jose State University, One Washington Sq, San Jose, CA, 95192, USA.
| |
Collapse
|
36
|
Noninvasive continuous blood pressure estimation with fewer parameters based on RA-ReliefF feature selection and MPGA-BPN models. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2023]
|
37
|
Ghosh A, Sarkar S, Liu H, Mandal S. Boosting Algorithms based Cuff-less Blood Pressure Estimation from Clinically Relevant ECG and PPG Morphological Features. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-6. [PMID: 38082568 DOI: 10.1109/embc40787.2023.10340405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Blood Pressure (BP) is often coined as a critical physiological marker for cardiovascular health. Multiple studies have explored either Photoplethysmogram (PPG) or ECG-PPG derived features for continuous BP estimation using machine learning (ML); deep learning (DL) techniques. Majority of those derived features often lack a stringent biological explanation and are not significantly correlated with BP. In this paper, we identified several clinically relevant (bio-inspired) ECG and PPG features; and exploited them to estimate Systolic (SBP), and Diastolic Blood Pressure (DBP) values using CatBoost, and AdaBoost algorithms. The estimation performance was then compared against popular ML algorithms. SBP and DBP achieved a Pearson's correlation coefficient of 0.90 and 0.83 between estimated and target BP values. The estimated mean absolute error (MAE) values are 3.81 and 2.22 mmHg with a Standard Deviation of 6.24 and 3.51 mmHg, respectively, for SBP and DBP using CatBoost. The results surpassed the Advancement of Medical Instrumentation (AAMI) standards. For the British Hypertension Society (BHS) protocol, the results achieved for all the BP categories resided in Grade A. Further investigation reveals that bio-inspired features along with tuned ML models can produce comparable results w.r.t parameter-intensive DL networks. ln(HR × mNPV), HR, BMI index, ageing index, and PPG-K point were identified as the top five key features for estimating BP. The group-based analysis further concludes that a trade-off lies between the number of features and MAE. Increasing the no. of features beyond a certain threshold saturates the reduction in MAE.
Collapse
|
38
|
Oliver E, Yue R, Dutta A. A Secure Vitals Monitoring Point-of-Care Device. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083555 DOI: 10.1109/embc40787.2023.10340768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Point-of-care (POC) devices continuously monitor vital signs and provide health suggestions to users. However, the devices are not affordable to everyone due to their cost. Here, we design a POC device that can continuously estimate vital signs using fewer sensors and lower costs. We do so by measuring photoplethysmogram signals and temperature and then estimating the heart rate, blood oxygen saturation, respiration rate, and blood pressure. For keeping the vital data secure, an auto-encoder and a convolutional neural network were also used for encryption and abnormality detection, respectively. Tests on the hardware showed the design accurately obtained users' vitals. The proposed design is expected to be generalized to obtain other vitals and fabricated at a low cost, making it affordable to all people.
Collapse
|
39
|
Zhang C, Shen Z, Ding X. Continual Learning for Cuffless Blood Pressure Measurement using PPG and ECG Signals. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083321 DOI: 10.1109/embc40787.2023.10340100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Although numerous studies have been conducted on cuffless blood pressure (BP) estimation using machine learning methods, most of the data-driven models are static, with model parameters fixed after training is complete. However, BP is dynamic and the performance would degrade for a static model when the to-be predicted BP distribution deviates from the training BP distribution. In this paper, we propose a continual learning (CL) framework in which deep learning models are developed to learn dynamically and continuously for arterial BP (ABP) estimation with photoplethysmography (PPG) and electrocardiogram (ECG) waveforms. The effectiveness of the CL model is validated on UCI Repository and MIMIC-III database with a total of 132 individual samples, and compared with conventional training method. It was found that the CL model improved the ABP estimation accuracy in terms of mean absolute error (MAE) by 17.47% on average compared with conventional training model. Furthermore, the improvement increased with the variability of ABP. These results demonstrate that CL model has potential to estimate dynamic ABP, which has been challenging with conventional training.
Collapse
|
40
|
Manga S, Muthavarapu N, Redij R, Baraskar B, Kaur A, Gaddam S, Gopalakrishnan K, Shinde R, Rajagopal A, Samaddar P, Damani DN, Shivaram S, Dey S, Mitra D, Roy S, Kulkarni K, Arunachalam SP. Estimation of Physiologic Pressures: Invasive and Non-Invasive Techniques, AI Models, and Future Perspectives. SENSORS (BASEL, SWITZERLAND) 2023; 23:5744. [PMID: 37420919 DOI: 10.3390/s23125744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 05/25/2023] [Accepted: 06/12/2023] [Indexed: 07/09/2023]
Abstract
The measurement of physiologic pressure helps diagnose and prevent associated health complications. From typical conventional methods to more complicated modalities, such as the estimation of intracranial pressures, numerous invasive and noninvasive tools that provide us with insight into daily physiology and aid in understanding pathology are within our grasp. Currently, our standards for estimating vital pressures, including continuous BP measurements, pulmonary capillary wedge pressures, and hepatic portal gradients, involve the use of invasive modalities. As an emerging field in medical technology, artificial intelligence (AI) has been incorporated into analyzing and predicting patterns of physiologic pressures. AI has been used to construct models that have clinical applicability both in hospital settings and at-home settings for ease of use for patients. Studies applying AI to each of these compartmental pressures were searched and shortlisted for thorough assessment and review. There are several AI-based innovations in noninvasive blood pressure estimation based on imaging, auscultation, oscillometry and wearable technology employing biosignals. The purpose of this review is to provide an in-depth assessment of the involved physiologies, prevailing methodologies and emerging technologies incorporating AI in clinical practice for each type of compartmental pressure measurement. We also bring to the forefront AI-based noninvasive estimation techniques for physiologic pressure based on microwave systems that have promising potential for clinical practice.
Collapse
Affiliation(s)
- Sharanya Manga
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Neha Muthavarapu
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Renisha Redij
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Avneet Kaur
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Sunil Gaddam
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Keerthy Gopalakrishnan
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Rutuja Shinde
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Poulami Samaddar
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Devanshi N Damani
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Internal Medicine, Texas Tech University Health Science Center, El Paso, TX 79995, USA
| | - Suganti Shivaram
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA
| | - Shuvashis Dey
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58105, USA
| | - Dipankar Mitra
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Computer Science, University of Wisconsin-La Crosse, La Crosse, WI 54601, USA
| | - Sayan Roy
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Electrical Engineering and Computer Science, South Dakota Mines, Rapid City, SD 57701, USA
| | - Kanchan Kulkarni
- Centre de Recherche Cardio-Thoracique de Bordeaux, University of Bordeaux, INSERM, U1045, 33000 Bordeaux, France
- IHU Liryc, Heart Rhythm Disease Institute, Fondation Bordeaux Université, Bordeaux, 33600 Pessac, France
| | - Shivaram P Arunachalam
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
41
|
Sel K, Mohammadi A, Pettigrew RI, Jafari R. Physics-informed neural networks for modeling physiological time series for cuffless blood pressure estimation. NPJ Digit Med 2023; 6:110. [PMID: 37296218 PMCID: PMC10256762 DOI: 10.1038/s41746-023-00853-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 05/24/2023] [Indexed: 06/12/2023] Open
Abstract
The bold vision of AI-driven pervasive physiological monitoring, through the proliferation of off-the-shelf wearables that began a decade ago, has created immense opportunities to extract actionable information for precision medicine. These AI algorithms model input-output relationships of a system that, in many cases, exhibits complex nature and personalization requirements. A particular example is cuffless blood pressure estimation using wearable bioimpedance. However, these algorithms need training over significant amount of ground truth data. In the context of biomedical applications, collecting ground truth data, particularly at the personalized level is challenging, burdensome, and in some cases infeasible. Our objective is to establish physics-informed neural network (PINN) models for physiological time series data that would use minimal ground truth information to extract complex cardiovascular information. We achieve this by building Taylor's approximation for gradually changing known cardiovascular relationships between input and output (e.g., sensor measurements to blood pressure) and incorporating this approximation into our proposed neural network training. The effectiveness of the framework is demonstrated through a case study: continuous cuffless BP estimation from time series bioimpedance data. We show that by using PINNs over the state-of-the-art time series models tested on the same datasets, we retain high correlations (systolic: 0.90, diastolic: 0.89) and low error (systolic: 1.3 ± 7.6 mmHg, diastolic: 0.6 ± 6.4 mmHg) while reducing the amount of ground truth training data on average by a factor of 15. This could be helpful in developing future AI algorithms to help interpret pervasive physiologic data using minimal amount of training data.
Collapse
Affiliation(s)
- Kaan Sel
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
| | - Amirmohammad Mohammadi
- Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA
| | | | - Roozbeh Jafari
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
- Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA.
- School of Engineering Medicine, Texas A&M University, Houston, TX, USA.
| |
Collapse
|
42
|
Seo Y, Kwon S, Sunarya U, Park S, Park K, Jung D, Cho Y, Park C. Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor. Biomed Eng Lett 2023; 13:221-233. [PMID: 37124108 PMCID: PMC10130301 DOI: 10.1007/s13534-023-00271-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 01/02/2023] [Accepted: 02/16/2023] [Indexed: 05/02/2023] Open
Abstract
The rapid evolution of wearable technology in healthcare sectors has created the opportunity for people to measure their blood pressure (BP) using a smartwatch at any time during their daily activities. Several commercially-available wearable devices have recently been equipped with a BP monitoring feature. However, concerns about recalibration remain. Pulse transit time (PTT)-based estimation is required for initial calibration, followed by periodic recalibration. Recalibration using arm-cuff BP monitors is not practical during everyday activities. In this study, we investigated recalibration using PTT-based BP monitoring aided by a deep neural network (DNN) and validated the performance achieved with more practical wrist-cuff BP monitors. The PTT-based prediction produced a mean absolute error (MAE) of 4.746 ± 1.529 mmHg for systolic blood pressure (SBP) and 3.448 ± 0.608 mmHg for diastolic blood pressure (DBP) when tested with an arm-cuff monitor employing recalibration. Recalibration clearly improved the performance of both DNN and conventional linear regression approaches. We established that the periodic recalibration performed by a wrist-worn BP monitor could be as accurate as that obtained with an arm-worn monitor, confirming the suitability of wrist-worn devices for everyday use. This is the first study to establish the potential of wrist-cuff BP monitors as a means to calibrate BP monitoring devices that can reliably substitute for arm-cuff BP monitors. With the use of wrist-cuff BP monitoring devices, continuous BP estimation, as well as frequent calibrations to ensure accurate BP monitoring, are now feasible.
Collapse
Affiliation(s)
- Youjung Seo
- Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea
| | - Saehim Kwon
- Department of Artificial Intelligence, Kwangwoon University, Seoul, 01897 Korea
| | - Unang Sunarya
- Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea
- School of Applied Science, Telkom University, Bandung, 40257 Indonesia
| | - Sungmin Park
- Department of Convergence IT Engineering and the Department of Electrical Engineering, Pohang University of Science and Technology, Pohang, 37673 Korea
| | - Kwangsuk Park
- Department of Biomedical Engineering, College of Medicine, Seoul National University, Seoul, 03080 Korea
| | - Dawoon Jung
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, 13916 Korea
| | - Youngho Cho
- Department of Electrical and Communication Engineering, University of Daelim, Anyang, 13916 Korea
| | - Cheolsoo Park
- Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea
| |
Collapse
|
43
|
Ma G, Zhang J, Liu J, Wang L, Yu Y. A Multi-Parameter Fusion Method for Cuffless Continuous Blood Pressure Estimation Based on Electrocardiogram and Photoplethysmogram. MICROMACHINES 2023; 14:804. [PMID: 37421037 DOI: 10.3390/mi14040804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/27/2023] [Accepted: 03/29/2023] [Indexed: 07/09/2023]
Abstract
Blood pressure (BP) is an essential physiological indicator to identify and determine health status. Compared with the isolated BP measurement conducted by traditional cuff approaches, cuffless BP monitoring can reflect the dynamic changes in BP values and is more helpful to evaluate the effectiveness of BP control. In this paper, we designed a wearable device for continuous physiological signal acquisition. Based on the collected electrocardiogram (ECG) and photoplethysmogram (PPG), we proposed a multi-parameter fusion method for noninvasive BP estimation. An amount of 25 features were extracted from processed waveforms and Gaussian copula mutual information (MI) was introduced to reduce feature redundancy. After feature selection, random forest (RF) was trained to realize systolic BP (SBP) and diastolic BP (DBP) estimation. Moreover, we used the records in public MIMIC-III as the training set and private data as the testing set to avoid data leakage. The mean absolute error (MAE) and standard deviation (STD) for SBP and DBP were reduced from 9.12 ± 9.83 mmHg and 8.31 ± 9.23 mmHg to 7.93 ± 9.12 mmHg and 7.63 ± 8.61 mmHg by feature selection. After calibration, the MAE was further reduced to 5.21 mmHg and 4.15 mmHg. The result showed that MI has great potential in feature selection during BP prediction and the proposed multi-parameter fusion method can be used for long-term BP monitoring.
Collapse
Affiliation(s)
- Gang Ma
- School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| | - Jie Zhang
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| | - Jing Liu
- School of Electronics and Information Technology, Soochow University, Suzhou 215031, China
| | - Lirong Wang
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
- School of Electronics and Information Technology, Soochow University, Suzhou 215031, China
| | - Yong Yu
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| |
Collapse
|
44
|
Qin C, Li Y, Liu C, Ma X. Cuff-Less Blood Pressure Prediction Based on Photoplethysmography and Modified ResNet. Bioengineering (Basel) 2023; 10:bioengineering10040400. [PMID: 37106587 PMCID: PMC10135940 DOI: 10.3390/bioengineering10040400] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 03/20/2023] [Accepted: 03/20/2023] [Indexed: 04/29/2023] Open
Abstract
Cardiovascular disease (CVD) has become a common health problem of mankind, and the prevalence and mortality of CVD are rising on a year-to-year basis. Blood pressure (BP) is an important physiological parameter of the human body and also an important physiological indicator for the prevention and treatment of CVD. Existing intermittent measurement methods do not fully indicate the real BP status of the human body and cannot get rid of the restraining feeling of a cuff. Accordingly, this study proposed a deep learning network based on the ResNet34 framework for continuous prediction of BP using only the promising PPG signal. The high-quality PPG signals were first passed through a multi-scale feature extraction module after a series of pre-processing to expand the perceptive field and enhance the perception ability on features. Subsequently, useful feature information was then extracted by stacking multiple residual modules with channel attention to increase the accuracy of the model. Lastly, in the training stage, the Huber loss function was adopted to stabilize the iterative process and obtain the optimal solution of the model. On a subset of the MIMIC dataset, the errors of both SBP and DBP predicted by the model met the AAMI standards, while the accuracy of DBP reached Grade A of the BHS standard, and the accuracy of SBP almost reached Grade A of the BHS standard. The proposed method verifies the potential and feasibility of PPG signals combined with deep neural networks in the field of continuous BP monitoring. Furthermore, the method is easy to deploy in portable devices, and it is more consistent with the future trend of wearable blood-pressure-monitoring devices (e.g., smartphones and smartwatches).
Collapse
Affiliation(s)
- Caijie Qin
- Institute of Information Engineering, Sanming University, Sanming 365004, China
- CBSR&NLPR, Institute of Automation, Chinese Academy of Sciences, Beijing 100049, China
| | - Yong Li
- Institute of Information Engineering, Sanming University, Sanming 365004, China
| | - Chibiao Liu
- Institute of Information Engineering, Sanming University, Sanming 365004, China
| | - Xibo Ma
- CBSR&NLPR, Institute of Automation, Chinese Academy of Sciences, Beijing 100049, China
- School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
45
|
Arora A, Arora A. Machine learning models trained on synthetic datasets of multiple sample sizes for the use of predicting blood pressure from clinical data in a national dataset. PLoS One 2023; 18:e0283094. [PMID: 36928534 PMCID: PMC10019654 DOI: 10.1371/journal.pone.0283094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Accepted: 03/01/2023] [Indexed: 03/18/2023] Open
Abstract
INTRODUCTION The potential for synthetic data to act as a replacement for real data in research has attracted attention in recent months due to the prospect of increasing access to data and overcoming data privacy concerns when sharing data. The field of generative artificial intelligence and synthetic data is still early in its development, with a research gap evidencing that synthetic data can adequately be used to train algorithms that can be used on real data. This study compares the performance of a series machine learning models trained on real data and synthetic data, based on the National Diet and Nutrition Survey (NDNS). METHODS Features identified to be potentially of relevance by directed acyclic graphs were isolated from the NDNS dataset and used to construct synthetic datasets and impute missing data. Recursive feature elimination identified only four variables needed to predict mean arterial blood pressure: age, sex, weight and height. Bayesian generalised linear regression, random forest and neural network models were constructed based on these four variables to predict blood pressure. Models were trained on the real data training set (n = 2408), a synthetic data training set (n = 2408) and larger synthetic data training set (n = 4816) and a combination of the real and synthetic data training set (n = 4816). The same test set (n = 424) was used for each model. RESULTS Synthetic datasets demonstrated a high degree of fidelity with the real dataset. There was no significant difference between the performance of models trained on real, synthetic or combined datasets. Mean average error across all models and all training data ranged from 8.12 To 8.33. This indicates that synthetic data was capable of training equally accurate machine learning models as real data. DISCUSSION Further research is needed on a variety of datasets to confirm the utility of synthetic data to replace the use of potentially identifiable patient data. There is also further urgent research needed into evidencing that synthetic data can truly protect patient privacy against adversarial attempts to re-identify real individuals from the synthetic dataset.
Collapse
Affiliation(s)
- Anmol Arora
- School of Clinical Medicine, University of Cambridge, Cambridge, United Kingdom
| | - Ananya Arora
- School of Clinical Medicine, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
46
|
Lee S, Joshi GP, Son CH, Lee G. Combining Gaussian Process with Hybrid Optimal Feature Decision in Cuffless Blood Pressure Estimation. Diagnostics (Basel) 2023; 13:diagnostics13040736. [PMID: 36832226 PMCID: PMC9955403 DOI: 10.3390/diagnostics13040736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 02/06/2023] [Accepted: 02/08/2023] [Indexed: 02/17/2023] Open
Abstract
Noninvasive blood pressure estimation is crucial for cardiovascular and hypertension patients. Cuffless-based blood pressure estimation has received much attention recently for continuous blood pressure monitoring. This paper proposes a new methodology that combines the Gaussian process with hybrid optimal feature decision (HOFD) in cuffless blood pressure estimation. First, we can choose one of the feature selection methods: robust neighbor component analysis (RNCA), minimum redundancy, maximum relevance (MRMR), and F-test, based on the proposed hybrid optimal feature decision. After that, a filter-based RNCA algorithm uses the training dataset to obtain weighted functions by minimizing the loss function. Next, we combine the Gaussian process (GP) algorithm as the evaluation criteria, which is used to determine the best feature subset. Hence, combining GP with HOFD leads to an effective feature selection process. The proposed combining Gaussian process with the RNCA algorithm shows that the root mean square errors (RMSEs) for the SBP (10.75 mmHg) and DBP (8.02 mmHg) are lower than those of the conventional algorithms. The experimental results represent that the proposed algorithm is very effective.
Collapse
Affiliation(s)
- Soojeong Lee
- Department of Computer Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea
| | - Gyanendra Prasad Joshi
- Department of Computer Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea
| | - Chang-Hwan Son
- Department of Software Science & Engineering, Kunsan National University, 558 Daehak-ro, Gunsan-si 54150, Republic of Korea
- Correspondence: (C.-H.S.); (G.L.)
| | - Gangseong Lee
- Ingenium College, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
- Correspondence: (C.-H.S.); (G.L.)
| |
Collapse
|
47
|
Visco V, Izzo C, Mancusi C, Rispoli A, Tedeschi M, Virtuoso N, Giano A, Gioia R, Melfi A, Serio B, Rusciano MR, Di Pietro P, Bramanti A, Galasso G, D’Angelo G, Carrizzo A, Vecchione C, Ciccarelli M. Artificial Intelligence in Hypertension Management: An Ace up Your Sleeve. J Cardiovasc Dev Dis 2023; 10:jcdd10020074. [PMID: 36826570 PMCID: PMC9963880 DOI: 10.3390/jcdd10020074] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/05/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023] Open
Abstract
Arterial hypertension (AH) is a progressive issue that grows in importance with the increased average age of the world population. The potential role of artificial intelligence (AI) in its prevention and treatment is firmly recognized. Indeed, AI application allows personalized medicine and tailored treatment for each patient. Specifically, this article reviews the benefits of AI in AH management, pointing out diagnostic and therapeutic improvements without ignoring the limitations of this innovative scientific approach. Consequently, we conducted a detailed search on AI applications in AH: the articles (quantitative and qualitative) reviewed in this paper were obtained by searching journal databases such as PubMed and subject-specific professional websites, including Google Scholar. The search terms included artificial intelligence, artificial neural network, deep learning, machine learning, big data, arterial hypertension, blood pressure, blood pressure measurement, cardiovascular disease, and personalized medicine. Specifically, AI-based systems could help continuously monitor BP using wearable technologies; in particular, BP can be estimated from a photoplethysmograph (PPG) signal obtained from a smartphone or a smartwatch using DL. Furthermore, thanks to ML algorithms, it is possible to identify new hypertension genes for the early diagnosis of AH and the prevention of complications. Moreover, integrating AI with omics-based technologies will lead to the definition of the trajectory of the hypertensive patient and the use of the most appropriate drug. However, AI is not free from technical issues and biases, such as over/underfitting, the "black-box" nature of many ML algorithms, and patient data privacy. In conclusion, AI-based systems will change clinical practice for AH by identifying patient trajectories for new, personalized care plans and predicting patients' risks and necessary therapy adjustments due to changes in disease progression and/or therapy response.
Collapse
Affiliation(s)
- Valeria Visco
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Carmine Izzo
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Costantino Mancusi
- Department of Advanced Biomedical Sciences, Federico II University of Naples, 80138 Naples, Italy
| | - Antonella Rispoli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Michele Tedeschi
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Nicola Virtuoso
- Cardiology Unit, University Hospital “San Giovanni di Dio e Ruggi d’Aragona”, 84131 Salerno, Italy
| | - Angelo Giano
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Renato Gioia
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Americo Melfi
- Cardiology Unit, University Hospital “San Giovanni di Dio e Ruggi d’Aragona”, 84131 Salerno, Italy
| | - Bianca Serio
- Hematology and Transplant Center, University Hospital “San Giovanni di Dio e Ruggi d’Aragona”, 84131 Salerno, Italy
| | - Maria Rosaria Rusciano
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Paola Di Pietro
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Alessia Bramanti
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Gennaro Galasso
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Gianni D’Angelo
- Department of Computer Science, University of Salerno, 84084 Fisciano, Italy
| | - Albino Carrizzo
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
- Vascular Physiopathology Unit, IRCCS Neuromed, 86077 Pozzilli, Italy
| | - Carmine Vecchione
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
- Vascular Physiopathology Unit, IRCCS Neuromed, 86077 Pozzilli, Italy
| | - Michele Ciccarelli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
- Correspondence:
| |
Collapse
|
48
|
Wang W, Mohseni P, Kilgore KL, Najafizadeh L. PulseDB: A large, cleaned dataset based on MIMIC-III and VitalDB for benchmarking cuff-less blood pressure estimation methods. Front Digit Health 2023; 4:1090854. [PMID: 36844249 PMCID: PMC9944565 DOI: 10.3389/fdgth.2022.1090854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 12/28/2022] [Indexed: 02/10/2023] Open
Abstract
There has been a growing interest in developing cuff-less blood pressure (BP) estimation methods to enable continuous BP monitoring from electrocardiogram (ECG) and/or photoplethysmogram (PPG) signals. The majority of these methods have been evaluated using publicly-available datasets, however, there exist significant discrepancies across studies with respect to the size, the number of subjects, and the applied pre-processing steps for the data that is eventually used for training and testing the models. Such differences make conducting performance comparison across models largely unfair, and mask the generalization capability of various BP estimation methods. To fill this important gap, this paper presents "PulseDB," the largest cleaned dataset to date, for benchmarking BP estimation models that also fulfills the requirements of standardized testing protocols. PulseDB contains 1) 5,245,454 high-quality 10 -s segments of ECG, PPG, and arterial BP (ABP) waveforms from 5,361 subjects retrieved from the MIMIC-III waveform database matched subset and the VitalDB database; 2) subjects' identification and demographic information, that can be utilized as additional input features to improve the performance of BP estimation models, or to evaluate the generalizability of the models to data from unseen subjects; and 3) positions of the characteristic points of the ECG/PPG signals, making PulseDB directly usable for training deep learning models with minimal data pre-processing. Additionally, using this dataset, we conduct the first study to provide insights about the performance gap between calibration-based and calibration-free testing approaches for evaluating generalizability of the BP estimation models. We expect PulseDB, as a user-friendly, large, comprehensive and multi-functional dataset, to be used as a reliable source for the evaluation of cuff-less BP estimation methods.
Collapse
Affiliation(s)
- Weinan Wang
- Integrated Systems and NeuroImaging Laboratory, Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, United States
| | - Pedram Mohseni
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Kevin L. Kilgore
- Department of Physical Medicine & Rehabilitation, Case Western Reserve University and The MetroHealth System, Cleveland, OH, United States
| | - Laleh Najafizadeh
- Integrated Systems and NeuroImaging Laboratory, Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, United States
| |
Collapse
|
49
|
Roy D, Mazumder O, Jaiswal D, Ghose A, Khandelwal S, Mandana K, Sinha A. In-silico cardiovascular hemodynamic model to simulate the effect of physical exercise. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.104364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
50
|
Rastegar S, Gholam Hosseini H, Lowe A. Hybrid CNN-SVR Blood Pressure Estimation Model Using ECG and PPG Signals. SENSORS (BASEL, SWITZERLAND) 2023; 23:1259. [PMID: 36772300 PMCID: PMC9921259 DOI: 10.3390/s23031259] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/14/2023] [Accepted: 01/20/2023] [Indexed: 06/18/2023]
Abstract
Continuous blood pressure (BP) measurement is vital in monitoring patients' health with a high risk of cardiovascular disease. The complex and dynamic nature of the cardiovascular system can influence BP through many factors, such as cardiac output, blood vessel wall elasticity, circulated blood volume, peripheral resistance, respiration, and emotional behavior. Yet, traditional BP measurement methods in continuously estimating the BP are cumbersome and inefficient. This paper presents a novel hybrid model by integrating a convolutional neural network (CNN) as a trainable feature extractor and support vector regression (SVR) as a regression model. This model can automatically extract features from the electrocardiogram (ECG) and photoplethysmography (PPG) signals and continuously estimates the systolic blood pressure (SBP) and diastolic blood pressure (DBP). The CNN takes the correct topology of input data and establishes the relationship between ECG and PPG features and BP. A total of 120 patients with available ECG, PPG, SBP, and DBP data are selected from the MIMIC III database to evaluate the performance of the proposed model. This novel model achieves an overall Mean Absolute Error (MAE) of 1.23 ± 2.45 mmHg (MAE ± STD) for SBP and 3.08 ± 5.67 for DBP, all of which comply with the accuracy requirements of the AAMI SP10 standard.
Collapse
Affiliation(s)
| | - Hamid Gholam Hosseini
- Institute of Biomedical Technologies, School of Engineering, Computing and Mathematical Sciences, Auckland University of Technology, Auckland 1010, New Zealand
| | - Andrew Lowe
- Institute of Biomedical Technologies, School of Engineering, Computing and Mathematical Sciences, Auckland University of Technology, Auckland 1010, New Zealand
| |
Collapse
|