1
|
Tang L, Shushtari M, Arami A. IMU-Based Real-Time Estimation of Gait Phase Using Multi-Resolution Neural Networks. SENSORS (BASEL, SWITZERLAND) 2024; 24:2390. [PMID: 38676007 PMCID: PMC11054798 DOI: 10.3390/s24082390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 03/26/2024] [Accepted: 04/07/2024] [Indexed: 04/28/2024]
Abstract
This work presents a real-time gait phase estimator using thigh- and shank-mounted inertial measurement units (IMUs). A multi-rate convolutional neural network (CNN) was trained to estimate gait phase for a dataset of 16 participants walking on an instrumented treadmill with speeds varying between 0.1 to 1.9 m/s, and conditions such as asymmetric walking, stop-start, and sudden speed changes. One-subject-out cross-validation was used to assess the robustness of the estimator to the gait patterns of new individuals. The proposed model had a spatial root mean square error of 5.00±1.65%, and a temporal mean absolute error of 2.78±0.97% evaluated at the heel strike. A second cross-validation was performed to show that leaving out any of the walking conditions from the training dataset did not result in significant performance degradation. A 2-sample Kolmogorov-Smirnov test showed that there was no significant increase in spatial or temporal error when testing on the abnormal walking conditions left out of the training set. The results of the two cross-validations demonstrate that the proposed model generalizes well across new participants, various walking speeds, and gait patterns, showcasing its potential for use in investigating patient populations with pathological gaits and facilitating robot-assisted walking.
Collapse
Affiliation(s)
- Lyndon Tang
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (M.S.); (A.A.)
| | - Mohammad Shushtari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (M.S.); (A.A.)
| | - Arash Arami
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada; (M.S.); (A.A.)
- KITE Institute, University Health Network, Toronto, ON M5G 2A2, Canada
| |
Collapse
|
2
|
Guo J, Guo C, Zhou J, Duan K, Wang Q. Flexible Capacitive Sensing and Ultrasound Calibration for Skeletal Muscle Deformations. Soft Robot 2022. [DOI: 10.1089/soro.2022.0065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Affiliation(s)
- Jiajie Guo
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Chuxuan Guo
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Jialei Zhou
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Kui Duan
- Huazhong University of Science and Technology, School Hospital, Wuhan, China
| | - Qining Wang
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing, China
| |
Collapse
|
3
|
Yang C, Yu L, Xu L, Yan Z, Hu D, Zhang S, Yang W. Current developments of robotic hip exoskeleton toward sensing, decision, and actuation: A review. WEARABLE TECHNOLOGIES 2022; 3:e15. [PMID: 38486916 PMCID: PMC10936331 DOI: 10.1017/wtc.2022.11] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/22/2022] [Accepted: 06/09/2022] [Indexed: 03/17/2024]
Abstract
The aging population is now a global challenge, and impaired walking ability is a common feature in the elderly. In addition, some occupations such as military and relief workers require extra physical help to perform tasks efficiently. Robotic hip exoskeletons can support ambulatory functions in the elderly and augment human performance in healthy people during normal walking and loaded walking by providing assistive torque. In this review, the current development of robotic hip exoskeletons is presented. In addition, the framework of actuation joints and the high-level control strategy (including the sensors and data collection, the way to recognize gait phase, the algorithms to generate the assist torque) are described. The exoskeleton prototypes proposed by researchers in recent years are organized to benefit the related fields realizing the limitations of the available robotic hip exoskeletons, therefore, this work tends to be an influential factor with a better understanding of the development and state-of-the-art technology.
Collapse
Affiliation(s)
- Canjun Yang
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
- School of Mechanical and Energy Engineering, NingboTech University, Ningbo, China
| | - Linfan Yu
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Linghui Xu
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Zehao Yan
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Dongming Hu
- School of Mechanical and Energy Engineering, NingboTech University, Ningbo, China
| | - Sheng Zhang
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Wei Yang
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
- School of Mechanical and Energy Engineering, NingboTech University, Ningbo, China
| |
Collapse
|
4
|
Comparison between Piezoelectric and Piezoresistive Wearable Gait Monitoring Techniques. MATERIALS 2022; 15:ma15144837. [PMID: 35888304 PMCID: PMC9321623 DOI: 10.3390/ma15144837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 07/05/2022] [Accepted: 07/06/2022] [Indexed: 12/04/2022]
Abstract
Insole plantar stress detection (PSD) techniques play an important role in gait monitoring. Among the various insole PSD methods, piezoelectric- and piezoresistive-based architectures are broadly used in medical scenes. Each year, a growing number of new research outcomes are reported. Hence, a deep understanding of these two kinds of insole PSD sensors and state-of-the-art work would strongly benefit the researchers in this highly interdisciplinary field. In this context, this review article is composed of the following aspects. First, the mechanisms of the two techniques and corresponding comparisons are explained and discussed. Second, advanced materials which could enhance the performance of current piezoelectric and piezoresistive insole prototypes are introduced. Third, suggestions for designing insole PSD prototypes/products for different diseases are offered. Last, the current challenge and potential future trends are provided.
Collapse
|
5
|
Xu D, Zhang Z, Crea S, Vitiello N, Wang Q. Adaptive estimation of continuous gait phase based on capacitive sensors. WEARABLE TECHNOLOGIES 2022; 3:e11. [PMID: 38486906 PMCID: PMC10936350 DOI: 10.1017/wtc.2022.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/25/2022] [Accepted: 03/25/2022] [Indexed: 03/17/2024]
Abstract
Continuous gait phase plays an important role in robotic prosthesis control. In this paper, we have conducted the offline adaptive estimation (at different speeds and on different ramps) of continuous gait phase of robotic transtibial prosthesis based on the adaptive oscillators. We have used the capacitive sensing method to record the deformation of the muscles. Two transtibial amputees joined in this study. Based on the strain signals of the prosthetic foot and the capacitive signals of the residual limb, the maximum and minimum of estimation errors are 0.80 rad and 0.054 rad, respectively, and their corresponding ratios in one gait cycle are 1.27% and 0.86%, respectively. This paper proposes an effective method to estimate the continuous gait phase based on the capacitive signals of the residual muscles, which provides a basis for the continuous control of robotic transtibial prosthesis.
Collapse
Affiliation(s)
- Dongfang Xu
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing100871, China
- Beijing Engineering Research Center of Intelligent Rehabilitation Engineering, Beijing, China
| | - Zhitong Zhang
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing100871, China
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Micro/Nano Electronics, Peking University, Beijing, China
| | - Simona Crea
- BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, Pisa, Italy
- IRCCS Fondazione Don Carlo Gnocchi, Milan, Italy
| | - Nicola Vitiello
- BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, Pisa, Italy
- IRCCS Fondazione Don Carlo Gnocchi, Milan, Italy
| | - Qining Wang
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing100871, China
- Beijing Engineering Research Center of Intelligent Rehabilitation Engineering, Beijing, China
- Institute for Artificial Intelligence, Peking University, Beijing, China
- University of Health and Rehabilitation Sciences, Qingdao, China
| |
Collapse
|
6
|
Pinto-Fernandez D, Torricelli D, Sanchez-Villamanan MDC, Aller F, Mombaur K, Conti R, Vitiello N, Moreno JC, Pons JL. Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review. IEEE Trans Neural Syst Rehabil Eng 2021; 28:1573-1583. [PMID: 32634096 DOI: 10.1109/tnsre.2020.2989481] [Citation(s) in RCA: 54] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Benchmarks have long been used to verify and compare the readiness level of different technologies in many application domains. In the field of wearable robots, the lack of a recognized benchmarking methodology is one important impediment that may hamper the efficient translation of research prototypes into actual products. At the same time, an exponentially growing number of research studies are addressing the problem of quantifying the performance of robotic exoskeletons, resulting in a rich and highly heterogeneous picture of methods, variables and protocols. This review aims to organize this information, and identify the most promising performance indicators that can be converted into practical benchmarks. We focus our analysis on lower limb functions, including a wide spectrum of motor skills and performance indicators. We found that, in general, the evaluation of lower limb exoskeletons is still largely focused on straight walking, with poor coverage of most of the basic motor skills that make up the activities of daily life. Our analysis also reveals a clear bias towards generic kinematics and kinetic indicators, in spite of the metrics of human-robot interaction. Based on these results, we identify and discuss a number of promising research directions that may help the community to attain a comprehensive benchmarking methodology for robot-assisted locomotion more efficiently.
Collapse
|
7
|
Xu D, Wang Q. Noninvasive Human-Prosthesis Interfaces for Locomotion Intent Recognition: A Review. CYBORG AND BIONIC SYSTEMS 2021; 2021:9863761. [PMID: 36285130 PMCID: PMC9494705 DOI: 10.34133/2021/9863761] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Accepted: 03/22/2021] [Indexed: 12/02/2022] Open
Abstract
The lower-limb robotic prostheses can provide assistance for amputees' daily activities by restoring the biomechanical functions of missing limb(s). To set proper control strategies and develop the corresponding controller for robotic prosthesis, a prosthesis user's intent must be acquired in time, which is still a major challenge and has attracted intensive attentions. This work focuses on the robotic prosthesis user's locomotion intent recognition based on the noninvasive sensing methods from the recognition task perspective (locomotion mode recognition, gait event detection, and continuous gait phase estimation) and reviews the state-of-the-art intent recognition techniques in a lower-limb prosthesis scope. The current research status, including recognition approach, progress, challenges, and future prospects in the human's intent recognition, has been reviewed. In particular for the recognition approach, the paper analyzes the recent studies and discusses the role of each element in locomotion intent recognition. This work summarizes the existing research results and problems and contributes a general framework for the intent recognition based on lower-limb prosthesis.
Collapse
Affiliation(s)
- Dongfang Xu
- Robotics Research Group, College of Engineering, Peking University, China
- Beijing Engineering Research Center of Intelligent Rehabilitation Engineering, China
| | - Qining Wang
- Robotics Research Group, College of Engineering, Peking University, China
- Beijing Engineering Research Center of Intelligent Rehabilitation Engineering, China
- The Beijing Innovation Center for Engineering Science and Advanced Technology (BIC-ESAT), Peking University, China
| |
Collapse
|
8
|
Wu X, Ma Y, Yong X, Wang C, He Y, Li N. Locomotion Mode Identification and Gait Phase Estimation for Exoskeletons During Continuous Multilocomotion Tasks. IEEE Trans Cogn Dev Syst 2021. [DOI: 10.1109/tcds.2019.2933648] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
Livolsi C, Conti R, Giovacchini F, Vitiello N, Crea S. A Novel Wavelet-Based Gait Segmentation Method for a Portable hip Exoskeleton. IEEE T ROBOT 2021. [DOI: 10.1109/tro.2021.3122975] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
10
|
Xu D, Wang Q. On-board Training Strategy for IMU-Based Real-Time Locomotion Recognition of Transtibial Amputees With Robotic Prostheses. Front Neurorobot 2020; 14:47. [PMID: 33192430 PMCID: PMC7642451 DOI: 10.3389/fnbot.2020.00047] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Accepted: 06/12/2020] [Indexed: 11/13/2022] Open
Abstract
The paper puts forward an on-board strategy for a training model and develops a real-time human locomotion mode recognition study based on a trained model utilizing two inertial measurement units (IMUs) of robotic transtibial prosthesis. Three transtibial amputees were recruited as subjects in this study to finish five locomotion modes (level ground walking, stair ascending, stair descending, ramp ascending, and ramp descending) with robotic prostheses. An interaction interface was designed to collect sensors' data and instruct to train model and recognition. In this study, the analysis of variance ratio (no more than 0.05) reflects the good repeatability of gait. The on-board training time for SVM (Support Vector Machines), QDA (Quadratic Discriminant Analysis), and LDA (Linear discriminant analysis) are 89, 25, and 10 s based on a 10,000 × 80 training data set, respectively. It costs about 13.4, 5.36, and 0.067 ms for SVM, QDA, and LDA for each recognition process. Taking the recognition accuracy of some previous studies and time consumption into consideration, we choose QDA for real-time recognition study. The real-time recognition accuracies are 97.19 ± 0.36% based on QDA, and we can achieve more than 95% recognition accuracy for each locomotion mode. The receiver operating characteristic also shows the good quality of QDA classifiers. This study provides a preliminary interaction design for human-machine prosthetics in future clinical application. This study just adopts two IMUs not multi-type sensors fusion to improve the integration and wearing convenience, and it maintains comparable recognition accuracy with multi-type sensors fusion at the same time.
Collapse
Affiliation(s)
- Dongfang Xu
- The Robotics Research Group, College of Engineering, Peking University, Beijing, China
- Beijing Engineering Research Center of Intelligent Rehabilitation Engineering, Beijing, China
| | - Qining Wang
- The Robotics Research Group, College of Engineering, Peking University, Beijing, China
- Beijing Engineering Research Center of Intelligent Rehabilitation Engineering, Beijing, China
- Beijing Innovation Center for Engineering Science and Advanced Technology, Peking University, Beijing, China
| |
Collapse
|
11
|
Zheng E, Wan J, Xu D, Wang Q, Qiao H. Identification of muscle morphology with noncontact capacitive sensing: Preliminary study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:4109-4113. [PMID: 33018902 DOI: 10.1109/embc44109.2020.9175438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Human-machine interface with muscle signals serves as an important role in the field of wearable robotics. To compensate for the limitations of the existing surface Electromyography (sEMG) based technologies, we previously proposed a noncontact capacitive sensing approach that could record the limb shape changes. The sensing approach frees the human skin from contacting to the metal electrodes, thus enabling the measurement of muscle signals by dressing the sensing front-ends outside of the clothes. We validated the capacitive sensing in human motion intent recognition tasks with the wearable robots and produced comparable results to existing studies. However, the biological significance of the capacitance signals is still unrevealed, which is an indispensable issue for robot intuitive control. In this study, we address the problems of identifying the relationships between the muscle morphological parameters and the capacitance signals. We constructed a measurement system that recorded the noncon-tact capacitive sensing signals and the muscle ultrasound (US) images simultaneously. With the designed device, five subjects were employed and the US images from the gastrocnemius muscle (GM) and the tibialis anterior (TA) muscle during level walking were sampled. We fitted the calculated muscle morphological parameters (the pinnation angles and the muscle fascicle length) and the capacitance signals of the same gait phases. The results demonstrated that at least one-channel capacitance signal strongly correlated to the muscle morphological parameters (R2 > 0.5, quadratic regression). The average R2s of the most correlated channels were up to 0.86 for pinnation angles and 0.83 for the muscle fascicle length changes. The interesting findings in this preliminary study suggest the biological physical significance of the capacitance signals during human locomotion. Future efforts are worth being paid in this new research direction for more promising results.
Collapse
|
12
|
Continuous Finite-Time Torque Control for Flexible Assistance Exoskeleton with Delay Variation Input. ROBOTICA 2020. [DOI: 10.1017/s0263574720000375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
SUMMARYAccurate torque control is a critical issue in the compliant human–robot interaction scenario, which is, however, challenging due to the ever-changing human intentions, input delay, and various disturbances. Even worse, the performances of existing control strategies are limited on account of the compromise between precision and stability. To this end, this paper presents a novel high-performance torque control scheme without compromise. In this scheme, a new nonlinear disturbance observer incorporated with equivalent control concept is proposed, where the faster convergence and stronger anti-noise capability can be obtained simultaneously. Meanwhile, a continuous fractional power control law is designed with an iteration method to address the matched/unmatched disturbance rejection and global finite-time convergence. Moreover, the finite-time stability proof and prescribed control performance are guaranteed using constructed Lyapunov function with adding power integrator technique. Both the simulation and experiments demonstrate enhanced control accuracy, faster convergence rate, perfect disturbance rejection capability, and stronger robustness of the proposed control scheme. Furthermore, the evaluated assistance effects present improved gait patterns and reduced muscle efforts during walking and upstair activity.
Collapse
|
13
|
Tschiedel M, Russold MF, Kaniusas E. Relying on more sense for enhancing lower limb prostheses control: a review. J Neuroeng Rehabil 2020; 17:99. [PMID: 32680530 PMCID: PMC7368691 DOI: 10.1186/s12984-020-00726-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 07/06/2020] [Indexed: 12/02/2022] Open
Abstract
Modern lower limb prostheses have the capability to replace missing body parts and improve the patients' quality of life. However, missing environmental information often makes a seamless adaptation to transitions between different forms of locomotion challenging. The aim of this review is to identify the progress made in this area over the last decade, addressing two main questions: which types of novel sensors for environmental awareness are used in lower limb prostheses, and how do they enhance device control towards more comfort and safety. A literature search was conducted on two Internet databases, PubMed and IEEE Xplore. Based on the criteria for inclusion and exclusion, 32 papers were selected for the review analysis, 18 of those are related to explicit environmental sensing and 14 to implicit environmental sensing. Characteristics were discussed with a focus on update rate and resolution as well as on computing power and energy consumption. Our analysis identified numerous state-of-the-art sensors, some of which are able to "look through" clothing or cosmetic covers. Five control categories were identified, how "next generation prostheses" could be extended. There is a clear tendency towards more upcoming object or terrain prediction concepts using all types of distance and depth-based sensors. Other advanced strategies, such as bilateral gait segmentation from unilateral sensors, could also play an important role in movement-dependent control applications. The studies demonstrated promising accuracy in well-controlled laboratory settings, but it is unclear how the systems will perform in real-world environments, both indoors and outdoors. At the moment the main limitation proves to be the necessity of having an unobstructed field of view.
Collapse
Affiliation(s)
- Michael Tschiedel
- Research Group Biomedical Sensing, TU Wien, Institute of Electrodynamics, Microwave and Circuit Engineering, Vienna, 1040 Austria
- Global Research, Ottobock Healthcare Products GmbH, Vienna, 1110 Austria
| | | | - Eugenijus Kaniusas
- Research Group Biomedical Sensing, TU Wien, Institute of Electrodynamics, Microwave and Circuit Engineering, Vienna, 1040 Austria
| |
Collapse
|
14
|
Gong C, Xu D, Zhou Z, Vitiello N, Wang Q. BPNN-Based Real-Time Recognition of Locomotion Modes for an Active Pelvis Orthosis with Different Assistive Strategies. INT J HUM ROBOT 2020. [DOI: 10.1142/s0219843620500048] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Real-time human intent recognition is important for controlling low-limb wearable robots. In this paper, to achieve continuous and precise recognition results on different terrains, we propose a real-time training and recognition method for six locomotion modes including standing, level ground walking, ramp ascending, ramp descending, stair ascending and stair descending. A locomotion recognition system is designed for the real-time recognition purpose with an embedded BPNN-based algorithm. A wearable powered orthosis integrated with this system and two inertial measurement units is used as the experimental setup to evaluate the performance of the designed method while providing hip assistance. Experiments including on-board training and real-time recognition parts are carried out on three able-bodied subjects. The overall recognition accuracies of six locomotion modes based on subject-dependent models are 98.43% and 98.03% respectively, with the wearable orthosis in two different assistance strategies. The cost time of recognition decision delivered to the orthosis is about 0.9[Formula: see text]ms. Experimental results show an effective and promising performance of the proposed method to realize real-time training and recognition for future control of low-limb wearable robots assisting users on different terrains.
Collapse
Affiliation(s)
- Cheng Gong
- The Robotics Research Group, College of Engineering, Peking University, Beijing 100871, P. R. China
| | - Dongfang Xu
- The Robotics Research Group, College of Engineering, Peking University, Beijing 100871, P. R. China
| | - Zhihao Zhou
- The Robotics Research Group, College of Engineering, Peking University, Beijing 100871, P. R. China
| | - Nicola Vitiello
- The BioRobotics Institute, Scuola Superiore SantAnna, Pisa 56127, Italy
| | - Qining Wang
- The Robotics Research Group, College of Engineering, Peking University, Beijing 100871, P. R. China
| |
Collapse
|
15
|
Ma Y, Wu X, Wang C, Yi Z, Liang G. Gait Phase Classification and Assist Torque Prediction for a Lower Limb Exoskeleton System Using Kernel Recursive Least-Squares Method. SENSORS (BASEL, SWITZERLAND) 2019; 19:s19245449. [PMID: 31835626 PMCID: PMC6961050 DOI: 10.3390/s19245449] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 11/23/2019] [Accepted: 11/26/2019] [Indexed: 06/10/2023]
Abstract
The gait phase classification method is a key technique to control an exoskeleton robot. Different people have different gait features while wearing an exoskeleton robot due to the gap between the exoskeleton and the wearer and their operation habits, such as the correspondence between the joint angle and the moment at which the foot contacts the ground, the amplitude of the joint angle and others. In order to enhance the performance of the gait phase classification in an exoskeleton robot using only the angle of hip and knee joints, a kernel recursive least-squares (KRLS) algorithm is introduced to build a gait phase classification model. We also build an assist torque predictor based on the KRLS algorithm in this work considering the adaptation of unique gait features. In this paper, we evaluate the classification performance of the KRLS model by comparing with two other commonly used gait recognition methods-the multi-layer perceptron neural network (MLPNN) method and the support vector machine (SVM) algorithm. In this experiment, the training and testing datasets for the models built by KRLS, MLPNN and SVM were collected from 10 healthy volunteers. The gait data are collected from the exoskeleton robot that we designed rather than collected from the human body. These data depict the human-robot coupling gait that includes unique gait features. The KRLS classification results are in average 3% higher than MLPNN and SVM. The testing average accuracy of KRLS is about 86%. The prediction results of KRLS are twice as good as MLPNN in assist torque prediction experiments. The KRLS performs in a good, stable, and robust way and shows model generalization abilities.
Collapse
Affiliation(s)
- Yue Ma
- Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.M.); (X.W.); (Z.Y.); (G.L.)
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen 518055, China
| | - Xinyu Wu
- Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.M.); (X.W.); (Z.Y.); (G.L.)
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen 518055, China
- SIAT Branch, Shenzhen Institute of Artificial Intelligence and Robotics for Society, Shenzhen 518055, China
| | - Can Wang
- Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.M.); (X.W.); (Z.Y.); (G.L.)
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen 518055, China
- SIAT Branch, Shenzhen Institute of Artificial Intelligence and Robotics for Society, Shenzhen 518055, China
| | - Zhengkun Yi
- Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.M.); (X.W.); (Z.Y.); (G.L.)
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen 518055, China
| | - Guoyuan Liang
- Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.M.); (X.W.); (Z.Y.); (G.L.)
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Shenzhen 518055, China
| |
Collapse
|
16
|
Grimmer M, Schmidt K, Duarte JE, Neuner L, Koginov G, Riener R. Stance and Swing Detection Based on the Angular Velocity of Lower Limb Segments During Walking. Front Neurorobot 2019; 13:57. [PMID: 31396072 PMCID: PMC6667673 DOI: 10.3389/fnbot.2019.00057] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 07/10/2019] [Indexed: 12/21/2022] Open
Abstract
Lower limb exoskeletons require the correct support magnitude and timing to achieve user assistance. This study evaluated whether the sign of the angular velocity of lower limb segments can be used to determine the timing of the stance and the swing phase during walking. We assumed that stance phase is characterized by a positive, swing phase by a negative angular velocity. Thus, the transitions can be used to also identify heel-strike and toe-off. Thirteen subjects without gait impairments walked on a treadmill at speeds between 0.5 and 2.1 m/s on level ground and inclinations between −10 and +10°. Kinematic and kinetic data was measured simultaneously from an optical motion capture system, force plates, and five inertial measurement units (IMUs). These recordings were used to compute the angular velocities of four lower limb segments: two biological (thigh, shank) and two virtual that were geometrical projections of the biological segments (virtual leg, virtual extended leg). We analyzed the reliability (two sign changes of the angular velocity per stride) and the accuracy (offset in timing between sign change and ground reaction force based timing) of the virtual and biological segments for detecting the gait phases stance and swing. The motion capture data revealed that virtual limb segments seem superior to the biological limb segments in the reliability of stance and swing detection. However, increased signal noise when using the IMUs required additional rule sets for reliable stance and swing detection. With IMUs, the biological shank segment had the least variability in accuracy. The IMU-based heel-strike events of the shank and both virtual segment were slightly early (3.3–4.8% of the gait cycle) compared to the ground reaction force-based timing. Toe-off event timing showed more variability (9.0% too early to 7.3% too late) between the segments and changed with walking speed. The results show that the detection of the heel-strike, and thus stance phase, based on IMU angular velocity is possible for different segments when additional rule sets are included. Further work is required to improve the timing accuracy for the toe-off detection (swing).
Collapse
Affiliation(s)
- Martin Grimmer
- Lauflabor Locomotion Laboratory, Department of Human Sciences, Institute of Sports Science, Technische Universität Darmstadt, Darmstadt, Germany
| | - Kai Schmidt
- Sensory-Motor Systems (SMS) Lab, Department of Health Sciences and Technology, Institute of Robotics and Intelligent Systems (IRIS), ETH Zurich, Zurich, Switzerland.,Spinal Cord Injury Center, University Hospital Balgrist, Zurich, Switzerland
| | - Jaime E Duarte
- Sensory-Motor Systems (SMS) Lab, Department of Health Sciences and Technology, Institute of Robotics and Intelligent Systems (IRIS), ETH Zurich, Zurich, Switzerland.,Spinal Cord Injury Center, University Hospital Balgrist, Zurich, Switzerland
| | - Lukas Neuner
- Sensory-Motor Systems (SMS) Lab, Department of Health Sciences and Technology, Institute of Robotics and Intelligent Systems (IRIS), ETH Zurich, Zurich, Switzerland
| | - Gleb Koginov
- Sensory-Motor Systems (SMS) Lab, Department of Health Sciences and Technology, Institute of Robotics and Intelligent Systems (IRIS), ETH Zurich, Zurich, Switzerland
| | - Robert Riener
- Sensory-Motor Systems (SMS) Lab, Department of Health Sciences and Technology, Institute of Robotics and Intelligent Systems (IRIS), ETH Zurich, Zurich, Switzerland.,Spinal Cord Injury Center, University Hospital Balgrist, Zurich, Switzerland
| |
Collapse
|
17
|
Abstract
SummaryNonlinear articular geometries of biological joints have contributed to highly agile and adaptable human-body motions. However, human–machine interaction could potentially distort natural human motions if the artificial mechanisms overload the articular surfaces and constrain biological joint kinematics. It is desired to better understand the deformable articular geometries of biological joints in vivo during movements for design and control of wearable robotics. An articular geometry reconstruction method is proposed to measure the effective articular profile with a wearable compliant device and illustrated with its application to knee-joint kinematic analysis. Regarding the joint articulation as boundary constraints for the compliant mechanism, the equivalent articular geometry is constructed from the beam deformations driven by knee motions, where the continuous deformations are estimated with strain data from the embedded sensors. Both simulated analysis and experimental validation are presented to justify the proposed method.
Collapse
|
18
|
Abstract
SummaryFor a real-time robotic prosthetic control, gait event detection plays an important role. In this paper, one novel sensor was proposed to realize gait event detection. The sensor includes one strain gauge bridge, which can reflect the entire deformation of carbon-fiber footplate on a robotic prosthesis. Three unilateral transtibial amputees participated in the experiments. Experimental results show that using the proposed sensor method, gait event detection (stance phase and swing phase) accuracy is approximately 100%. Based on the detected gait events, three locomotion modes (sit, stand, and walk) and the corresponding transition modes could be determined. Difference between different gait event detection systems was further conducted.
Collapse
|
19
|
Zheng E, Wang Q, Qiao H. Identification of the relationships between noncontact capacitive sensing signals and continuous grasp forces: Preliminary study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:3922-3925. [PMID: 30441218 DOI: 10.1109/embc.2018.8513251] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This study explores the relationships between noncontact capacitive sensing signals and continuous grasp forces. It is a crucial step towards the volitional control of robotic systems based on the noncontact sensing approach. We firstly designed a measurement system including the capacitive sensing front-ends, the grasp force sensor, the signal sampling circuits and the graphic user interface. The capacitive sensing front-end was specifically designed for human forearm signal sampling, which was worn outside of the clothes. After implementation of the system, we carried out experiments on five healthy subjects, and the sensing bands were customized with their arm shapes. The grasp force and the capacitance signals were record simultaneously when the subjects gradually increased the force according to instruction. Linear regression and quadratic regression were used to evaluate the regulated signals. For each subject, at least one channel of capacitance signals were linear correlated to the normalized grasp force with ${{R}^{2}}\ge 0.85$. We found there was inter-subject similarity on the capacitance-force relationships. Cross validation on grasp force estimation with capacitance signals were also carried out, and the average relative estimation error was about 18%. The results proved the feasibility of the noncontact capacitive sensing method for human joint force estimation.
Collapse
|
20
|
Xu D, Feng Y, Mai J, Wang Q. Real-Time On-Board Recognition of Continuous Locomotion Modes for Amputees With Robotic Transtibial Prostheses. IEEE Trans Neural Syst Rehabil Eng 2018; 26:2015-2025. [DOI: 10.1109/tnsre.2018.2870152] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
21
|
Zheng E, Mai J, Liu Y, Wang Q. Forearm Motion Recognition With Noncontact Capacitive Sensing. Front Neurorobot 2018; 12:47. [PMID: 30100872 PMCID: PMC6072882 DOI: 10.3389/fnbot.2018.00047] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Accepted: 07/04/2018] [Indexed: 11/13/2022] Open
Abstract
This study presents a noncontact capacitive sensing method for forearm motion recognition. A method is proposed to record upper limb motion information from muscle contractions without contact with human skin, compensating for the limitations of existing sEMG-based methods. The sensing front-ends are designed based on human forearm shapes, and the forearm limb shape changes caused by muscle contractions will be represented by capacitance signals. After implementation of the capacitive sensing system, experiments on healthy subjects are conducted to evaluate the effectiveness. Nine motion patterns combined with 16 motion transitions are investigated on seven participants. We also designed an automatic data labeling method based on inertial signals from the measured hand, which greatly accelerated the training procedure. With the capacitive sensing system and the designed recognition algorithm, the method produced an average recognition of over 92%. Correct decisions could be made with approximately a 347-ms delay from the relaxed state to the time point of motion initiation. The confounding factors that affect the performances are also analyzed, including the sliding window length, the motion types and the external disturbances. We found the average accuracy increased to 98.7% when five motion patterns were recognized. The results of the study proved the feasibility and revealed the problems of the noncontact capacitive sensing approach on upper-limb motion sensing and recognition. Future efforts in this direction could be worthwhile for achieving more promising outcomes.
Collapse
Affiliation(s)
- Enhao Zheng
- The State Key Laboratory of Management and Control for Complex Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, China
| | - Jingeng Mai
- The Robotics Research Group, College of Engineering, Peking University, Beijing, China
- The Beijing Innovation Center for Engineering Science and Advanced Technology (BIC-ESAT), Peking University, Beijing, China
| | - Yuxiang Liu
- The Robotics Research Group, College of Engineering, Peking University, Beijing, China
| | - Qining Wang
- The Robotics Research Group, College of Engineering, Peking University, Beijing, China
- The Beijing Innovation Center for Engineering Science and Advanced Technology (BIC-ESAT), Peking University, Beijing, China
| |
Collapse
|
22
|
Dong W, Wang Y, Zhou Y, Bai Y, Ju Z, Guo J, Gu G, Bai K, Ouyang G, Chen S, Zhang Q, Huang Y. Soft human–machine interfaces: design, sensing and stimulation. INTERNATIONAL JOURNAL OF INTELLIGENT ROBOTICS AND APPLICATIONS 2018. [DOI: 10.1007/s41315-018-0060-z] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|