1
|
Dhawan V, Cui XT. Carbohydrate based biomaterials for neural interface applications. J Mater Chem B 2022; 10:4714-4740. [PMID: 35702979 DOI: 10.1039/d2tb00584k] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Neuroprosthetic devices that record and modulate neural activities have demonstrated immense potential for bypassing or restoring lost neurological functions due to neural injuries and disorders. However, implantable electrical devices interfacing with brain tissue are susceptible to a series of inflammatory tissue responses along with mechanical or electrical failures which can affect the device performance over time. Several biomaterial strategies have been implemented to improve device-tissue integration for high quality and stable performance. Ranging from developing smaller, softer, and more flexible electrode designs to introducing bioactive coatings and drug-eluting layers on the electrode surface, such strategies have shown different degrees of success but with limitations. With their hydrophilic properties and specific bioactivities, carbohydrates offer a potential solution for addressing some of the limitations of the existing biomolecular approaches. In this review, we summarize the role of polysaccharides in the central nervous system, with a primary focus on glycoproteins and proteoglycans, to shed light on their untapped potential as biomaterials for neural implants. Utilization of glycosaminoglycans for neural interface and tissue regeneration applications is comprehensively reviewed to provide the current state of carbohydrate-based biomaterials for neural implants. Finally, we will discuss the challenges and opportunities of applying carbohydrate-based biomaterials for neural tissue interfaces.
Collapse
Affiliation(s)
- Vaishnavi Dhawan
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA. .,Center for Neural Basis of Cognition, Pittsburgh, PA, USA
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA. .,Center for Neural Basis of Cognition, Pittsburgh, PA, USA.,McGowan Institute for Regenerative Medicine, Pittsburgh, PA, USA
| |
Collapse
|
2
|
Carnicer-Lombarte A, Chen ST, Malliaras GG, Barone DG. Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics. Front Bioeng Biotechnol 2021; 9:622524. [PMID: 33937212 PMCID: PMC8081831 DOI: 10.3389/fbioe.2021.622524] [Citation(s) in RCA: 132] [Impact Index Per Article: 44.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 03/19/2021] [Indexed: 12/04/2022] Open
Abstract
The implantation of any foreign material into the body leads to the development of an inflammatory and fibrotic process-the foreign body reaction (FBR). Upon implantation into a tissue, cells of the immune system become attracted to the foreign material and attempt to degrade it. If this degradation fails, fibroblasts envelop the material and form a physical barrier to isolate it from the rest of the body. Long-term implantation of medical devices faces a great challenge presented by FBR, as the cellular response disrupts the interface between implant and its target tissue. This is particularly true for nerve neuroprosthetic implants-devices implanted into nerves to address conditions such as sensory loss, muscle paralysis, chronic pain, and epilepsy. Nerve neuroprosthetics rely on tight interfacing between nerve tissue and electrodes to detect the tiny electrical signals carried by axons, and/or electrically stimulate small subsets of axons within a nerve. Moreover, as advances in microfabrication drive the field to increasingly miniaturized nerve implants, the need for a stable, intimate implant-tissue interface is likely to quickly become a limiting factor for the development of new neuroprosthetic implant technologies. Here, we provide an overview of the material-cell interactions leading to the development of FBR. We review current nerve neuroprosthetic technologies (cuff, penetrating, and regenerative interfaces) and how long-term function of these is limited by FBR. Finally, we discuss how material properties (such as stiffness and size), pharmacological therapies, or use of biodegradable materials may be exploited to minimize FBR to nerve neuroprosthetic implants and improve their long-term stability.
Collapse
Affiliation(s)
- Alejandro Carnicer-Lombarte
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Shao-Tuan Chen
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - George G. Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Damiano G. Barone
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
- Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
3
|
Abstract
When nerves are damaged by trauma or disease, they are still capable of firing off electrical command signals that originate from the brain. Furthermore, those damaged nerves have an innate ability to partially regenerate, so they can heal from trauma and even reinnervate new muscle targets. For an amputee who has his/her damaged nerves surgically reconstructed, the electrical signals that are generated by the reinnervated muscle tissue can be sensed and interpreted with bioelectronics to control assistive devices or robotic prostheses. No two amputees will have identical physiologies because there are many surgical options for reconstructing residual limbs, which may in turn impact how well someone can interface with a robotic prosthesis later on. In this review, we aim to investigate what the literature has to say about different pathways for peripheral nerve regeneration and how each pathway can impact the neuromuscular tissue’s final electrophysiology. This information is important because it can guide us in planning the development of future bioelectronic devices, such as prosthetic limbs or neurostimulators. Future devices will primarily have to interface with tissue that has undergone some natural regeneration process, and so we have explored and reported here what is known about the bioelectrical features of neuromuscular tissue regeneration.
Collapse
|
4
|
Ferrari LM, Rodríguez-Meana B, Bonisoli A, Cutrone A, Micera S, Navarro X, Greco F, Del Valle J. All-Polymer Printed Low-Cost Regenerative Nerve Cuff Electrodes. Front Bioeng Biotechnol 2021; 9:615218. [PMID: 33644015 PMCID: PMC7902501 DOI: 10.3389/fbioe.2021.615218] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 01/11/2021] [Indexed: 11/13/2022] Open
Abstract
Neural regeneration after lesions is still limited by several factors and new technologies are developed to address this issue. Here, we present and test in animal models a new regenerative nerve cuff electrode (RnCE). It is based on a novel low-cost fabrication strategy, called "Print and Shrink", which combines the inkjet printing of a conducting polymer with a heat-shrinkable polymer substrate for the development of a bioelectronic interface. This method allows to produce miniaturized regenerative cuff electrodes without the use of cleanroom facilities and vacuum based deposition methods, thus highly reducing the production costs. To fully proof the electrodes performance in vivo we assessed functional recovery and adequacy to support axonal regeneration after section of rat sciatic nerves and repair with RnCE. We investigated the possibility to stimulate the nerve to activate different muscles, both in acute and chronic scenarios. Three months after implantation, RnCEs were able to stimulate regenerated motor axons and induce a muscular response. The capability to produce fully-transparent nerve interfaces provided with polymeric microelectrodes through a cost-effective manufacturing process is an unexplored approach in neuroprosthesis field. Our findings pave the way to the development of new and more usable technologies for nerve regeneration and neuromodulation.
Collapse
Affiliation(s)
- Laura M Ferrari
- Center for Micro-BioRobotics @SSSA, Istituto Italiano di Tecnologia, Pontedera, Italy.,The BioRobotics Institute and Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pontedera, Italy.,Université Côte d'Azur, INRIA, Sophia Antipolis, France
| | - Bruno Rodríguez-Meana
- Department of Cell Biology, Physiology and Immunology, Institute of Neurosciences, Universitat Autònoma de Barcelona, and CIBERNED, Bellaterra, Spain
| | - Alberto Bonisoli
- Center for Micro-BioRobotics @SSSA, Istituto Italiano di Tecnologia, Pontedera, Italy.,The BioRobotics Institute and Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pontedera, Italy
| | - Annarita Cutrone
- The BioRobotics Institute and Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pontedera, Italy
| | - Silvestro Micera
- The BioRobotics Institute and Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pontedera, Italy.,Bertarelli Foundation Chair in Translational NeuroEngineering, Center for Neuroprosthetics and Institute of Bioengineering, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland
| | - Xavier Navarro
- Department of Cell Biology, Physiology and Immunology, Institute of Neurosciences, Universitat Autònoma de Barcelona, and CIBERNED, Bellaterra, Spain
| | - Francesco Greco
- Center for Micro-BioRobotics @SSSA, Istituto Italiano di Tecnologia, Pontedera, Italy.,Institute of Solid State Physics, NAWI Graz, Graz University of Technology, Graz, Austria.,Department of Life Science and Medical Bioscience, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan
| | - Jaume Del Valle
- Department of Cell Biology, Physiology and Immunology, Institute of Neurosciences, Universitat Autònoma de Barcelona, and CIBERNED, Bellaterra, Spain
| |
Collapse
|
5
|
Spearman BS, Kuliasha CA, Judy JW, Schmidt CE. Integration of flexible polyimide arrays into soft extracellular matrix-based hydrogel materials for a tissue-engineered electronic nerve interface (TEENI). J Neurosci Methods 2020; 341:108762. [PMID: 32413377 PMCID: PMC8086190 DOI: 10.1016/j.jneumeth.2020.108762] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 04/20/2020] [Accepted: 05/04/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND Biomimetic hydrogels used in tissue engineering can improve tissue regeneration and enable targeted cellular behavior; there is growing interest in combining hydrogels with microelectronics to create new neural interface platforms to help patient populations. However, effective processes must be developed to integrate flexible but relatively stiff (e.g., 1-10 GPa) microelectronic arrays within soft (e.g., 1-10 kPa) hydrogels. NEW METHOD Here, a novel method for integrating polyimide microelectrode arrays within a biomimetic hydrogel scaffold is demonstrated for use as a tissue-engineered electronic nerve interface (TEENI). Tygon tubing and a series of 3D printed molds were used to facilitate hydrogel fabrication and device assembly. COMPARISON WITH EXISTING METHODS Other comparable regenerative peripheral nerve interface technologies do not utilize the flexible microelectrode array design nor the hydrogel scaffold described here. These methods typically use stiff electrode arrays that are affixed to a similarly stiff implantable tube serving as the nerve guidance conduit. RESULTS Our results indicate that there is a substantial mechanical mismatch between the flexible microelectronic arrays and the soft hydrogel. However, using the methods described here, there is consistent fabrication of these regenerative peripheral nerve interfaces suitable for implantation. CONCLUSIONS The assembly process that was developed resulted in repeatable and consistent integration of microelectrode arrays within a soft tissue-engineered hydrogel. As reported elsewhere, these devices have been successfully implanted in a rat sciatic nerve model and yielded neural recordings. This process can be adapted for other applications and hydrogels in which flexible electronic materials are combined with soft regenerative scaffolds.
Collapse
Affiliation(s)
- Benjamin S Spearman
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States
| | - Cary A Kuliasha
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, United States; Nanoscience Institute for Medical and Engineering Technology, University of Florida, Gainesville, FL, United States
| | - Jack W Judy
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, United States; Nanoscience Institute for Medical and Engineering Technology, University of Florida, Gainesville, FL, United States
| | - Christine E Schmidt
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.
| |
Collapse
|
6
|
Yildiz KA, Shin AY, Kaufman KR. Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review. J Neuroeng Rehabil 2020; 17:43. [PMID: 32151268 PMCID: PMC7063740 DOI: 10.1186/s12984-020-00667-5] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Accepted: 02/17/2020] [Indexed: 12/22/2022] Open
Abstract
The field of prosthetics has been evolving and advancing over the past decade, as patients with missing extremities are expecting to control their prostheses in as normal a way as possible. Scientists have attempted to satisfy this expectation by designing a connection between the nervous system of the patient and the prosthetic limb, creating the field of neuroprosthetics. In this paper, we broadly review the techniques used to bridge the patient's peripheral nervous system to a prosthetic limb. First, we describe the electrical methods including myoelectric systems, surgical innovations and the role of nerve electrodes. We then describe non-electrical methods used alone or in combination with electrical methods. Design concerns from an engineering point of view are explored, and novel improvements to obtain a more stable interface are described. Finally, a critique of the methods with respect to their long-term impacts is provided. In this review, nerve electrodes are found to be one of the most promising interfaces in the future for intuitive user control. Clinical trials with larger patient populations, and for longer periods of time for certain interfaces, will help to evaluate the clinical application of nerve electrodes.
Collapse
Affiliation(s)
- Kadir A Yildiz
- Motion Analysis Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Alexander Y Shin
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Kenton R Kaufman
- Motion Analysis Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
- Motion Analysis Laboratory, W. Hall Wendel, Jr., Musculoskeletal Research, 200 First Street SW, Rochester, MN, 55905, USA.
| |
Collapse
|
7
|
Cutrone A, Micera S. Implantable Neural Interfaces and Wearable Tactile Systems for Bidirectional Neuroprosthetics Systems. Adv Healthc Mater 2019; 8:e1801345. [PMID: 31763784 DOI: 10.1002/adhm.201801345] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 03/22/2019] [Indexed: 12/12/2022]
Abstract
Neuroprosthetics and neuromodulation represent a promising field for several related applications in the central and peripheral nervous system, such as the treatment of neurological disorders, the control of external robotic devices, and the restoration of lost tactile functions. These actions are allowed by the neural interface, a miniaturized implantable device that most commonly exploits electrical energy to fulfill these operations. A neural interface must be biocompatible, stable over time, low invasive, and highly selective; the challenge is to develop a safe, compact, and reliable tool for clinical applications. In case of anatomical impairments, neuroprosthetics is bound to the need of exploring the surrounding environment by fast-responsive and highly sensitive artificial tactile sensors that mimic the natural sense of touch. Tactile sensors and neural interfaces are closely interconnected since the readouts from the first are required to convey information to the neural implantable apparatus. The role of these devices is pivotal hence technical improvements are essential to ensure a secure system to be eventually adopted in daily life. This review highlights the fundamental criteria for the design and microfabrication of neural interfaces and artificial tactile sensors, their use in clinical applications, and future enhancements for the release of a second generation of devices.
Collapse
Affiliation(s)
- Annarita Cutrone
- The Biorobotics Institute, Viale Rinaldo Piaggio 34, 56025, Pontedera, Italy
| | - Silvestro Micera
- The Biorobotics Institute, Viale Rinaldo Piaggio 34, 56025, Pontedera, Italy
- Bertarelli Foundation Chair in Translational Neuroengineering, Centre for Neuroprosthetics and Institute of Bioengineering, School of Engineering, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne, CH-1202, Switzerland
| |
Collapse
|
8
|
A review for the peripheral nerve interface designer. J Neurosci Methods 2019; 332:108523. [PMID: 31743684 DOI: 10.1016/j.jneumeth.2019.108523] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 11/14/2019] [Accepted: 11/15/2019] [Indexed: 12/11/2022]
Abstract
Informational density and relative accessibility of the peripheral nervous system make it an attractive site for therapeutic intervention. Electrode-based electrophysiological interfaces with peripheral nerves have been under development since the 1960s and, for several applications, have seen widespread clinical implementation. However, many applications require a combination of neural target resolution and stability which has thus far eluded existing peripheral nerve interfaces (PNIs). With the goal of aiding PNI designers in development of devices that meet the demands of next-generation applications, this review seeks to collect and present practical considerations and best practices which emerge from the literature, including both lessons learned during early PNI development and recent ideas. Fundamental and practical principles guiding PNI design are reviewed, followed by an updated and critical account of existing PNI designs and strategies. Finally, a brief survey of in vitro and in vivo PNI characterization methods is presented.
Collapse
|
9
|
Zellmer ER, MacEwan MR, Moran DW. Modelling the impact of altered axonal morphometry on the response of regenerative nervous tissue to electrical stimulation through macro-sieve electrodes. J Neural Eng 2019; 15:026009. [PMID: 29192607 DOI: 10.1088/1741-2552/aa9e96] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Regenerated peripheral nervous tissue possesses different morphometric properties compared to undisrupted nerve. It is poorly understood how these morphometric differences alter the response of the regenerated nerve to electrical stimulation. In this work, we use computational modeling to explore the electrophysiological response of regenerated and undisrupted nerve axons to electrical stimulation delivered by macro-sieve electrodes (MSEs). APPROACH A 3D finite element model of a peripheral nerve segment populated with mammalian myelinated axons and implanted with a macro-sieve electrode has been developed. Fiber diameters and morphometric characteristics representative of undisrupted or regenerated peripheral nervous tissue were assigned to core conductor models to simulate the two tissue types. Simulations were carried out to quantify differences in thresholds and chronaxie between undisrupted and regenerated fiber populations. The model was also used to determine the influence of axonal caliber on recruitment thresholds for the two tissue types. Model accuracy was assessed through comparisons with in vivo recruitment data from chronically implanted MSEs. MAIN RESULTS Recruitment thresholds of individual regenerated fibers with diameters >2 µm were found to be lower compared to same caliber undisrupted fibers at electrode to fiber distances of less than about 90-140 µm but roughly equal or higher for larger distances. Caliber redistributions observed in regenerated nerve resulted in an overall increase in average recruitment thresholds and chronaxie during whole nerve stimulation. Modeling results also suggest that large diameter undisrupted fibers located close to a longitudinally restricted current source such as the MSE have higher average recruitment thresholds compared to small diameter fibers. In contrast, large diameter regenerated nerve fibers located in close proximity of MSE sites have, on average, lower recruitment thresholds compared to small fibers. Utilizing regenerated fiber morphometry and caliber distributions resulted in accurate predictions of in vivo recruitment data. SIGNIFICANCE Our work uses computational modeling to show how morphometric differences between regenerated and undisrupted tissue results in recruitment threshold discrepancies, quantifies these differences, and illustrates how large undisrupted nerve fibers close to longitudinally restricted current sources have higher recruitment thresholds compared to adjacently positioned smaller fibers while the opposite is true for large regenerated fibers.
Collapse
Affiliation(s)
- Erik R Zellmer
- Department of Biomedical Engineering, Washington University, St. Louis, MO 63130, United States of America
| | | | | |
Collapse
|
10
|
Renz AF, Reichmuth AM, Stauffer F, Thompson-Steckel G, Vörös J. A guide towards long-term functional electrodes interfacing neuronal tissue. J Neural Eng 2018; 15:061001. [DOI: 10.1088/1741-2552/aae0c2] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
11
|
Petersen BA, Nanivadekar AC, Chandrasekaran S, Fisher LE. Phantom limb pain: peripheral neuromodulatory and neuroprosthetic approaches to treatment. Muscle Nerve 2018; 59:154-167. [DOI: 10.1002/mus.26294] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/01/2018] [Indexed: 12/11/2022]
Affiliation(s)
- Bailey A. Petersen
- Department of Bioengineering; University of Pittsburgh; 3520 Fifth Avenue, Pittsburgh Pennsylvania 15213 USA
| | - Ameya C. Nanivadekar
- Department of Bioengineering; University of Pittsburgh; 3520 Fifth Avenue, Pittsburgh Pennsylvania 15213 USA
| | - Santosh Chandrasekaran
- Department of Physical Medicine and Rehabilitation; University of Pittsburgh; Pittsburgh Pennsylvania USA
| | - Lee E. Fisher
- Department of Bioengineering; University of Pittsburgh; 3520 Fifth Avenue, Pittsburgh Pennsylvania 15213 USA
- Department of Physical Medicine and Rehabilitation; University of Pittsburgh; Pittsburgh Pennsylvania USA
| |
Collapse
|
12
|
Delgado-Martínez I, Righi M, Santos D, Cutrone A, Bossi S, D'Amico S, Del Valle J, Micera S, Navarro X. Fascicular nerve stimulation and recording using a novel double-aisle regenerative electrode. J Neural Eng 2018; 14:046003. [PMID: 28382924 DOI: 10.1088/1741-2552/aa6bac] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE As artificial prostheses become more refined, they are most often used as a therapeutic option for hand amputation. By contrast to extra- or intraneural interfaces, regenerative nerve electrodes are designed to enable electrical interfaces with regrowing axonal bundles of injured nerves, aiming to achieve high selectivity for recording and stimulation. However, most of the developed designs pose an obstacle to the regrowth mechanisms due to low transparency and cause impairment to the nerve regeneration. APPROACH Here we present the double-aisle electrode, a new type of highly transparent, non-obstructive regenerative electrode. Using a double-side thin-film polyimide planar multi-contact electrode, two nerve fascicles can regenerate without physical impairment through two electrically isolated aisles. MAIN RESULTS We show that this electrode can be used to selectively record and stimulate fascicles, acutely as well as chronically, and allow regeneration in nerve gaps of several millimeters without impairment. SIGNIFICANCE This multi-aisle regenerative electrode may be suitable for neuroprosthetic applications, such as prostheses, for the restoration of hand function after amputation or severe nerve injuries.
Collapse
Affiliation(s)
- I Delgado-Martínez
- Department of Cell Biology, Physiology and Immunology, Institute of Neurosciences, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Spearman BS, Desai VH, Mobini S, McDermott MD, Graham JB, Otto KJ, Judy JW, Schmidt CE. Tissue-Engineered Peripheral Nerve Interfaces. ADVANCED FUNCTIONAL MATERIALS 2018; 28:1701713. [PMID: 37829558 PMCID: PMC10569514 DOI: 10.1002/adfm.201701713] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2023]
Abstract
Research on neural interfaces has historically concentrated on development of systems for the brain; however, there is increasing interest in peripheral nerve interfaces (PNIs) that could provide benefit when peripheral nerve function is compromised, such as for amputees. Efforts focus on designing scalable and high-performance sensory and motor peripheral nervous system interfaces. Current PNIs face several design challenges such as undersampling of signals from the thousands of axons, nerve-fiber selectivity, and device-tissue integration. To improve PNIs, several researchers have turned to tissue engineering. Peripheral nerve tissue engineering has focused on designing regeneration scaffolds that mimic normal nerve extracellular matrix composition, provide advanced microarchitecture to stimulate cell migration, and have mechanical properties like the native nerve. By combining PNIs with tissue engineering, the goal is to promote natural axon regeneration into the devices to facilitate close contact with electrodes; in contrast, traditional PNIs rely on insertion or placement of electrodes into or around existing nerves, or do not utilize materials to actively facilitate axon regeneration. This review presents the state-of-the-art of PNIs and nerve tissue engineering, highlights recent approaches to combine neural-interface technology and tissue engineering, and addresses the remaining challenges with foreign-body response.
Collapse
Affiliation(s)
- Benjamin S Spearman
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
| | - Vidhi H Desai
- Department of Electrical and Computer Engineering, The University of Florida, 216 Larsen Hall, 116200, Gainesville, FL 32611-6200
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
| | - Sahba Mobini
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
| | - Matthew D McDermott
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Dr., West Lafayette, IN 47907-2032
| | - James B Graham
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
| | - Kevin J Otto
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
- Department of Neuroscience, The University of Florida, 1149 Newell Dr., Room L1-100, 100244, Gainesville, FL 32610-0244
- Department of Neurology, The University of Florida, 2000 SW Archer Rd., Third Floor, 100383, Gainesville, FL 32610
| | - Jack W Judy
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Department of Electrical and Computer Engineering, The University of Florida, 216 Larsen Hall, 116200, Gainesville, FL 32611-6200
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
| | - Christine E Schmidt
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
| |
Collapse
|
14
|
Righi M, Puleo GL, Tonazzini I, Giudetti G, Cecchini M, Micera S. Peptide-based coatings for flexible implantable neural interfaces. Sci Rep 2018; 8:502. [PMID: 29323135 PMCID: PMC5765121 DOI: 10.1038/s41598-017-17877-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 11/29/2017] [Indexed: 11/23/2022] Open
Abstract
In the last decade, the use of flexible biosensors for neuroprosthetic and translational applications has widely increased. Among them, the polyimide (PI)-based thin-film electrodes got a large popularity. However, the usability of these devices is still hampered by a non-optimal tissue-device interface that usually compromises the long-term quality of neural signals. Advanced strategies able to improve the surface properties of these devices have been developed in the recent past. Unfortunately, most of them are not easy to be developed and combined with micro-fabrication processes, and require long-term efforts to be testable with human subjects. Here we show the results of the design and in vitro testing of an easy-to-implement and potentially interesting coating approach for thin-film electrodes. In particular, two biocompatible coatings were obtained via covalent conjugation of a laminin-derived peptide, CAS-IKVAV-S (IKV), with polyimide sheets that we previously functionalized with vinyl- and amino- groups (PI_v and PI_a respectively). Both the engineered coatings (PI_v+IKV and PI_a+IKV) showed morphological and chemical properties able to support neuronal adhesion, neurite sprouting, and peripheral glial cell viability while reducing the fibroblasts contamination of the substrate. In particular, PI_v+IKV showed promising results that encourage further in vivo investigation and pave the way for a new generation of peptide-coated thin-film electrodes.
Collapse
Affiliation(s)
- Martina Righi
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, 56025, Pontedera (PI), Italy.
| | - Gian Luigi Puleo
- Istituto Italiano di Tecnologia, Center of Micro-BioRobotics@SSSA, Viale Rinaldo Piaggio 34, 56025, Pontedera (PI), Italy
| | - Ilaria Tonazzini
- NEST (National Enterprise for nanoScience and nanoTechnology), Istituto Nanoscienze-CNR & Scuola Normale Superiore, Piazza San Silvestro 12, 56127, Pisa, Italy
| | - Guido Giudetti
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, 56025, Pontedera (PI), Italy
| | - Marco Cecchini
- NEST (National Enterprise for nanoScience and nanoTechnology), Istituto Nanoscienze-CNR & Scuola Normale Superiore, Piazza San Silvestro 12, 56127, Pisa, Italy
| | - Silvestro Micera
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, 56025, Pontedera (PI), Italy. .,Bertarelli Foundation Chair in NeuroEngineering, Center for Neuroprosthetics and Institute of Bioengineering (IBI)-School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
| |
Collapse
|
15
|
Preferential Enhancement of Sensory and Motor Axon Regeneration by Combining Extracellular Matrix Components with Neurotrophic Factors. Int J Mol Sci 2016; 18:ijms18010065. [PMID: 28036084 PMCID: PMC5297700 DOI: 10.3390/ijms18010065] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 11/28/2016] [Accepted: 12/24/2016] [Indexed: 11/29/2022] Open
Abstract
After peripheral nerve injury, motor and sensory axons are able to regenerate but inaccuracy of target reinnervation leads to poor functional recovery. Extracellular matrix (ECM) components and neurotrophic factors (NTFs) exert their effect on different neuronal populations creating a suitable environment to promote axonal growth. Here, we assessed in vitro and in vivo the selective effects of combining different ECM components with NTFs on motor and sensory axons regeneration and target reinnervation. Organotypic cultures with collagen, laminin and nerve growth factor (NGF)/neurotrophin-3 (NT3) or collagen, fibronectin and brain-derived neurotrophic factor (BDNF) selectively enhanced sensory neurite outgrowth of DRG neurons and motor neurite outgrowth from spinal cord slices respectively. For in vivo studies, the rat sciatic nerve was transected and repaired with a silicone tube filled with a collagen and laminin matrix with NGF/NT3 encapsulated in poly(lactic-co-glycolic acid) (PLGA) microspheres (MP) (LM + MP.NGF/NT3), or a collagen and fibronectin matrix with BDNF in PLGA MPs (FN + MP.BDNF). Retrograde labeling and functional tests showed that LM + MP.NGF/NT3 increased the number of regenerated sensory neurons and improved sensory functional recovery, whereas FN + MP.BDNF preferentially increased regenerated motoneurons and enhanced motor functional recovery. Therefore, combination of ECM molecules with NTFs may be a good approach to selectively enhance motor and sensory axons regeneration and promote appropriate target reinnervation.
Collapse
|
16
|
Guo L. The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective. Front Neurosci 2016; 10:599. [PMID: 28082862 PMCID: PMC5186773 DOI: 10.3389/fnins.2016.00599] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Accepted: 12/15/2016] [Indexed: 12/19/2022] Open
Abstract
Brain-computer interfaces represent one of the most astonishing technologies in our era. However, the grand challenge of chronic instability and limited throughput of the electrode-tissue interface has significantly hindered the further development and ultimate deployment of such exciting technologies. A multidisciplinary research workforce has been called upon to respond to this engineering need. In this paper, I briefly review this multidisciplinary pursuit of chronically reliable neural interfaces from a materials perspective by analyzing the problem, abstracting the engineering principles, and summarizing the corresponding engineering strategies. I further draw my future perspectives by extending the proposed engineering principles.
Collapse
Affiliation(s)
- Liang Guo
- Department of Electrical and Computer Engineering, The Ohio State UniversityColumbus, OH, USA; Department of Neuroscience, The Ohio State UniversityColumbus, OH, USA
| |
Collapse
|
17
|
Xiang Z, Sheshadri S, Lee S, Wang J, Xue N, Thakor NV, Yen S, Lee C. Mapping of Small Nerve Trunks and Branches Using Adaptive Flexible Electrodes. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2016; 3:1500386. [PMID: 27981020 PMCID: PMC5039981 DOI: 10.1002/advs.201500386] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Revised: 01/21/2016] [Indexed: 05/29/2023]
Abstract
Selective stimulation is delivered to the sciatic nerve using different paris of contacts on a split-ring electrode, while simulatneous recordings are acquired by the neural ribbon electrodes on three different branches. Two hook electrodes are also implanted in the muscle to monitor the activated muscle responses. It shows that the high precision implantation of electrodes, increases the efficacy and reduces the incidence of side effects.
Collapse
Affiliation(s)
- Zhuolin Xiang
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
- Center for Intelligent Sensors and MEMSNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
| | - Swathi Sheshadri
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
| | - Sang‐Hoon Lee
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
- Center for Intelligent Sensors and MEMSNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
| | - Jiahui Wang
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
- Center for Intelligent Sensors and MEMSNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
| | - Ning Xue
- Institute of Microelectronics (IME)Agency for Science, Technology and Research (A*STAR)11 Science Park Road, Singapore Science Park IISingapore117685Singapore
| | - Nitish V. Thakor
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
- Department of Biomedical EngineeringSchool of MedicineJohns Hopkins University BaltimoreMD21205USA
| | - Shih‐Cheng Yen
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
| | - Chengkuo Lee
- Department of Electrical and Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117583Singapore
- Singapore Institute for Neurotechnology (SiNAPSE)National University of Singapore28 Medical Drive, #05‐CORSingapore117456Singapore
- Center for Intelligent Sensors and MEMSNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
| |
Collapse
|
18
|
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording. Med Biol Eng Comput 2016; 54:23-44. [PMID: 26753777 DOI: 10.1007/s11517-015-1430-4] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Accepted: 12/10/2015] [Indexed: 12/22/2022]
Abstract
Electrodes serve as the first critical interface to the biological organ system. In neuroprosthetic applications, for example, electrodes interface to the tissue for either signal recording or tissue stimulation. In this review, we consider electrodes for recording neural activity. Recording electrodes serve as wiretaps into the neural tissues, providing readouts of electrical activity. These signals give us valuable insights into the organization and functioning of the nervous system. The recording interfaces have also shown promise in aiding treatment of motor and sensory disabilities caused by neurological disorders. Recent advances in fabrication technology have generated wide interest in creating tiny, high-density electrode interfaces for neural tissues. An ideal electrode should be small enough and be able to achieve reliable and conformal integration with the structures of the nervous system. As a result, the existing electrode designs are being shrunk and packed to form small form factor interfaces to tissue. Here, an overview of the historic and state-of-the-art electrode technologies for recording neural activity is presented first with a focus on their development road map. The fact that the dimensions of recording electrode sites are being scaled down from micron to submicron scale to enable dense interfaces is appreciated. The current trends in recording electrode technologies are then reviewed. Current and future considerations in electrode design, including the use of inorganic nanostructures and biologically inspired or biocomapatible materials are discussed, along with an overview of the applications of flexible materials and transistor transduction schemes. Finally, we detail the major technical challenges facing chronic use of reliable recording electrode technology.
Collapse
|
19
|
Bonakdar M, Latouche EL, Mahajan RL, Davalos RV. The Feasibility of a Smart Surgical Probe for Verification of IRE Treatments Using Electrical Impedance Spectroscopy. IEEE Trans Biomed Eng 2015; 62:2674-84. [PMID: 26057529 DOI: 10.1109/tbme.2015.2441636] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
SIGNIFICANCE Irreversible electroporation (IRE) is gaining popularity as a focal ablation modality for the treatment of unresectable tumors. One clinical limitation of IRE is the absence of methods for real-time treatment evaluation, namely actively monitoring the dimensions of the induced lesion. This information is critical to ensure a complete treatment and minimize collateral damage to the surrounding healthy tissue. GOAL In this study, we are taking advantage of the biophysical properties of living tissues to address this critical demand. METHODS Using advanced microfabrication techniques, we have developed an electrical impedance microsensor to collect impedance data along the length of a bipolar IRE probe for treatment verification. For probe characterization and interpretation of the readings, we used potato tuber, which is a suitable platform for IRE experiments without having the complexities of in vivo or ex vivo models. We used the impedance spectra, along with an electrical model of the tissue, to obtain critical parameters such as the conductivity of the tissue before, during, and after completion of treatment. To validate our results, we used a finite element model to simulate the electric field distribution during treatments in each potato. RESULTS It is shown that electrical impedance spectroscopy could be used as a technique for treatment verification, and when combined with appropriate FEM modeling can determine the lesion dimensions. CONCLUSIONS This technique has the potential to be readily translated for use with other ablation modalities already being used in clinical settings for the treatment of malignancies.
Collapse
|
20
|
Srinivasan A, Tipton J, Tahilramani M, Kharbouch A, Gaupp E, Song C, Venkataraman P, Falcone J, Lacour SP, Stanley GB, English AW, Bellamkonda RV. A regenerative microchannel device for recording multiple single-unit action potentials in awake, ambulatory animals. Eur J Neurosci 2015; 43:474-85. [PMID: 26370722 DOI: 10.1111/ejn.13080] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 08/07/2015] [Accepted: 09/08/2015] [Indexed: 12/28/2022]
Abstract
Despite significant advances in robotics, commercially advanced prosthetics provide only a small fraction of the functionality of the amputated limb that they are meant to replace. Peripheral nerve interfacing could provide a rich controlling link between the body and these advanced prosthetics in order to increase their overall utility. Here, we report on the development of a fully integrated regenerative microchannel interface with 30 microelectrodes and signal extraction capabilities enabling evaluation in an awake and ambulatory rat animal model. In vitro functional testing validated the capability of the microelectrodes to record neural signals similar in size and nature to those that occur in vivo. In vitro dorsal root ganglia cultures revealed striking cytocompatibility of the microchannel interface. Finally, in vivo, the microchannel interface was successfully used to record a multitude of single-unit action potentials through 63% of the integrated microelectrodes at the early time point of 3 weeks. This marks a significant advance in microchannel interfacing, demonstrating the capability of microchannels to be used for peripheral nerve interfacing.
Collapse
Affiliation(s)
- Akhil Srinivasan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - John Tipton
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Mayank Tahilramani
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Adel Kharbouch
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Eric Gaupp
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Chao Song
- School of Electrical and Computer Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, GA, USA
| | - Poornima Venkataraman
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Jessica Falcone
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Stéphanie P Lacour
- Centre for Neuroprosthetics, School of Engineering, Institute of Microengineering and Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne, Switzerland
| | - Garrett B Stanley
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| | - Arthur W English
- Department of Cell Biology, Emory University School of Medicine, Atlanta, GA, USA
| | - Ravi V Bellamkonda
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, 313 Ferst Drive, Atlanta, GA, 30332, USA
| |
Collapse
|
21
|
Lee S, Yen SC, Sheshadri S, Delgado-Martinez I, Xue N, Xiang Z, Thakor NV, Lee C. Flexible Epineural Strip Electrode for Recording in Fine Nerves. IEEE Trans Biomed Eng 2015; 63:581-7. [PMID: 26276980 DOI: 10.1109/tbme.2015.2466442] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper demonstrates flexible epineural strip electrodes (FLESE) for recording from small nerves. Small strip-shaped FLESE enables us to easily and closely stick on various sized nerves for less damage in a nerve and optimal recording quality. In addition, in order to enhance the neural interface, the gold electrode contacts were coated with carbon nanotubes, which reduced the impedance of the electrodes. We used the FLESEs to record electrically elicited nerve signals (compound neural action potentials) from the sciatic nerve in rats. Bipolar and differential bipolar configurations for the recording were investigated to optimize the recording configuration of the FLESEs. The successful results from differential bipolar recordings showed that the total length of FLESEs could be further reduced, maintaining the maximum recording ability, which would be beneficial for recording in very fine nerves. Our results demonstrate that new concept of FLESEs could play an important role in electroceuticals in near future.
Collapse
|
22
|
Update in facial nerve paralysis: tissue engineering and new technologies. Curr Opin Otolaryngol Head Neck Surg 2015; 22:291-9. [PMID: 24979369 DOI: 10.1097/moo.0000000000000062] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PURPOSE OF REVIEW To present the recent advances in the treatment of facial paralysis, emphasizing the emerging technologies. This review will summarize the current state of the art in the management of facial paralysis and discuss the advances in nerve regeneration, facial reanimation, and use of novel biomaterials. This review includes surgical innovations in reinnervation and reanimation as well as progress with bioelectrical interfaces. RECENT FINDINGS The last decade has witnessed major advances in the understanding of nerve injury and approaches for management. Key innovations include strategies to accelerate nerve regeneration, provide tissue-engineered constructs that may replace nonfunctional nerves, approaches to influence axonal guidance, limiting of donor-site morbidity, and optimization of functional outcomes. Approaches to muscle transfer continue to evolve, and new technologies allow for electrical nerve stimulation and use of artificial tissues. SUMMARY The fields of biomedical engineering and facial reanimation increasingly intersect, with innovative surgical approaches complementing a growing array of tissue engineering tools. The goal of treatment remains the predictable restoration of natural facial movement, with acceptable morbidity and long-term stability. Advances in bioelectrical interfaces and nanotechnology hold promise for widening the window for successful treatment intervention and for restoring both lost neural inputs and muscle function.
Collapse
|
23
|
Tan DW, Schiefer MA, Keith MW, Anderson JR, Tyler DJ. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees. J Neural Eng 2015; 12:026002. [PMID: 25627310 DOI: 10.1088/1741-2560/12/2/026002] [Citation(s) in RCA: 101] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. APPROACH Multi-contact cuff electrodes were implanted in the median, ulnar, and radial nerves of the upper-limb. MAIN RESULTS Nerve stimulation produced a selective sensory response on 19 of 20 contacts and 16 of 16 contacts in subjects 1 and 2, respectively. Stimulation elicited multiple, distinct percept areas on the phantom and residual limb. Consistent threshold, impedance, and percept areas have demonstrated that the neural interface is stable for the duration of this on-going, chronic study. SIGNIFICANCE We have achieved selective nerve response from multi-contact cuff electrodes by demonstrating characteristic percept areas and thresholds for each contact. Selective sensory response remains consistent in two upper-limb amputees for 1 and 2 years, the longest multi-contact sensory feedback system to date. Our approach demonstrates selectivity and stability can be achieved through an extraneural interface, which can provide sensory feedback to amputees.
Collapse
Affiliation(s)
- Daniel W Tan
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH 44106, USA. Case Western Reserve University, Cleveland, OH 44106, USA
| | | | | | | | | |
Collapse
|
24
|
Gore RK, Choi Y, Bellamkonda R, English A. Functional recordings from awake, behaving rodents through a microchannel based regenerative neural interface. J Neural Eng 2015; 12:016017. [PMID: 25605627 DOI: 10.1088/1741-2560/12/1/016017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
OBJECTIVE Neural interface technologies could provide controlling connections between the nervous system and external technologies, such as limb prosthetics. The recording of efferent, motor potentials is a critical requirement for a peripheral neural interface, as these signals represent the user-generated neural output intended to drive external devices. Our objective was to evaluate structural and functional neural regeneration through a microchannel neural interface and to characterize potentials recorded from electrodes placed within the microchannels in awake and behaving animals. APPROACH Female rats were implanted with muscle EMG electrodes and, following unilateral sciatic nerve transection, the cut nerve was repaired either across a microchannel neural interface or with end-to-end surgical repair. During a 13 week recovery period, direct muscle responses to nerve stimulation proximal to the transection were monitored weekly. In two rats repaired with the neural interface, four wire electrodes were embedded in the microchannels and recordings were obtained within microchannels during proximal stimulation experiments and treadmill locomotion. MAIN RESULTS In these proof-of-principle experiments, we found that axons from cut nerves were capable of functional reinnervation of distal muscle targets, whether regenerating through a microchannel device or after direct end-to-end repair. Discrete stimulation-evoked and volitional potentials were recorded within interface microchannels in a small group of awake and behaving animals and their firing patterns correlated directly with intramuscular recordings during locomotion. Of 38 potentials extracted, 19 were identified as motor axons reinnervating tibialis anterior or soleus muscles using spike triggered averaging. SIGNIFICANCE These results are evidence for motor axon regeneration through microchannels and are the first report of in vivo recordings from regenerated motor axons within microchannels in a small group of awake and behaving animals. These unique findings provide preliminary evidence that efferent, volitional motor potentials can be recorded from the microchannel-based peripheral neural interface; a critical requirement for any neural interface intended to facilitate direct neural control of external technologies.
Collapse
Affiliation(s)
- Russell K Gore
- Department of Neurology, Emory University School of Medicine, 550 Peachtree Street NE, 9th Floor MOT, Atlanta, GA 30308, USA. Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory School of Medicine, 1760 Haygood Drive NE, Atlanta, GA 30322, USA
| | | | | | | |
Collapse
|
25
|
Ambrosio F, Boninger ML, Brubaker CE, Delitto A, Wagner WR, Shields RK, Wolf SL, Rando TA. Guest editorial: emergent themes from second annual symposium on regenerative rehabilitation, Pittsburgh, Pennsylvania. ACTA ACUST UNITED AC 2014; 50:vii-xiv. [PMID: 23881770 DOI: 10.1682/jrrd.2013.04.0081] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
26
|
Abstract
Advancements in modern robotic technology have led to the development of highly sophisticated upper extremity prosthetic limbs. High-fidelity volitional control of these devices is dependent on the critical interface between the patient and the mechanical prosthesis. Recent innovations in prosthetic interfaces have focused on several control strategies. Targeted muscle reinnervation is currently the most immediately applicable prosthetic control strategy and is particularly indicated in proximal upper extremity amputations. Investigation into various brain interfaces has allowed acquisition of neuroelectric signals directly or indirectly from the central nervous system for prosthetic control. Peripheral nerve interfaces permit signal transduction from both motor and sensory nerves with a higher degree of selectivity. This article reviews the current developments in each of these interface systems and discusses the potential of these approaches to facilitate motor control and sensory feedback in upper extremity neuroprosthetic devices.
Collapse
|
27
|
Owens CM, Marga F, Forgacs G, Heesch CM. Biofabrication and testing of a fully cellular nerve graft. Biofabrication 2013; 5:045007. [PMID: 24192236 DOI: 10.1088/1758-5082/5/4/045007] [Citation(s) in RCA: 116] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Rupture of a nerve is a debilitating injury with devastating consequences for the individual's quality of life. The gold standard of repair is the use of an autologous graft to bridge the severed nerve ends. Such repair however involves risks due to secondary surgery at the donor site and may result in morbidity and infection. Thus the clinical approach to repair often involves non-cellular solutions, grafts composed of synthetic or natural materials. Here we report on a novel approach to biofabricate fully biological grafts composed exclusively of cells and cell secreted material. To reproducibly and reliably build such grafts of composite geometry we use bioprinting. We test our grafts in a rat sciatic nerve injury model for both motor and sensory function. In particular we compare the regenerative capacity of the biofabricated grafts with that of autologous grafts and grafts made of hollow collagen tubes by measuring the compound action potential (for motor function) and the change in mean arterial blood pressure as consequence of electrically eliciting the somatic pressor reflex. Our results provide evidence that bioprinting is a promising approach to nerve graft fabrication and as a consequence to nerve regeneration.
Collapse
Affiliation(s)
- Christopher M Owens
- Department of Physics and Astronomy, University of Missouri, Columbia, MO 65211, USA
| | | | | | | |
Collapse
|
28
|
Interfaces with the peripheral nerve for the control of neuroprostheses. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2013; 109:63-83. [PMID: 24093606 DOI: 10.1016/b978-0-12-420045-6.00002-x] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Nervous system injuries lead to loss of control of sensory, motor, and autonomic functions of the affected areas of the body. Provided the high amount of people worldwide suffering from these injuries and the impact on their everyday life, numerous and different neuroprostheses and hybrid bionic systems have been developed to restore or partially mimic the lost functions. A key point for usable neuroprostheses is the electrode that interfaces the nervous system and translates not only motor orders into electrical outputs that activate the prosthesis but is also able to transform sensory information detected by the machine into signals that are transmitted to the central nervous system. Nerve electrodes have been classified with regard to their invasiveness in extraneural, intraneural, and regenerative. The more invasive is the implant the more selectivity of interfacing can be reached. However, boosting invasiveness and selectivity may also heighten nerve damage. This chapter provides a general overview of nerve electrodes as well as the state-of-the-art of their biomedical applications in neuroprosthetic systems.
Collapse
|