1
|
Jargieło A, Sterliński M, Oręziak A, Pracoń R, Kołsut P. Complications of transvenous lead extraction-focus on tricuspid valve damage: a case report. Eur Heart J Case Rep 2025; 9:ytae695. [PMID: 39811751 PMCID: PMC11732274 DOI: 10.1093/ehjcr/ytae695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 07/24/2024] [Accepted: 12/19/2024] [Indexed: 01/16/2025]
Abstract
Background Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications. Case summary An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection. Approximately 1 year prior, he underwent the implantation of a new ventricular lead and pacemaker replacement due to lead damage and battery depletion. Another lead had been abandoned. The patient underwent a procedure to remove the entire pacing system, which was complicated by tricuspid leaflet avulsion, resulting in acute and severe tricuspid regurgitation. A biological valve was successfully implanted to replace the damaged valve. Twenty days later, a new pacing system was implanted, which included one atrial lead and another positioned in the posterolateral coronary vein of the left ventricle. Post-procedural transthoracic echocardiography (TTE) showed the biological valve in place at the tricuspid orifice, with no regurgitation and preserved ejection fraction. Following recovery, the patient was discharged in good condition. Discussion While pre-procedural TTE and intra-procedural transesophageal echocardiography are commonly used to identify lead-induced tricuspid insufficiency, they often do not clarify the underlying mechanisms or predict potential complications during TLE. To address this issue safely, further research into new imaging techniques is necessary, as some existing methods may not be adequate in certain situations.
Collapse
Affiliation(s)
- Anna Jargieło
- 1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland
| | - Maciej Sterliński
- 1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland
| | - Artur Oręziak
- 1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland
| | - Radosław Pracoń
- 1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland
| | - Piotr Kołsut
- 1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland
| |
Collapse
|
2
|
Nowosielecka D, Jacheć W, Stefańczyk Dzida M, Polewczyk A, Mościcka D, Nowosielecka A, Kutarski A. What Important Information Does Transesophageal Echocardiography Provide When Performed before Transvenous Lead Extraction? J Clin Med 2024; 13:5278. [PMID: 39274491 PMCID: PMC11396690 DOI: 10.3390/jcm13175278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 08/25/2024] [Accepted: 09/02/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Transesophageal echocardiography (TEE) is mandatory before transvenous lead extraction (TLE), but its usefulness remains underestimated. This study aims to describe the broad range of TEE findings in TLE candidates, as well as their influence on procedure complexity, major complications (MCs) and long-term survival. Methods: Preoperative TEE was performed in 1191 patients undergoing TLE. Results: Lead thickening (OR = 1.536; p = 0.007), lead adhesion to heart structures (OR = 2.531; p < 0.001) and abnormally long lead loops (OR = 1.632; p = 0.006) increased the complexity of TLE. Vegetation-like masses on the lead (OR = 4.080; p = 0.44), lead thickening (OR = 2.389; p = 0.049) and lead adhesion to heart structures (OR = 6.341; p < 0.001) increased the rate of MCs. The presence of vegetations (HR = 7.254; p < 0.001) was the strongest predictor of death during a 1-year follow-up period. Conclusions: TEE before TLE provides a lot of important information for the operator. Apart from the visualization of possible vegetations, it can also detect various forms of lead-related scar tissue. Build-up of scar tissue and the presence of long lead loops are associated with increased complexity of the procedure and risk of MCs. Preoperative TEE performed outside the operating room may have an impact on the clinical decision-making process, such as transferring potentially more difficult patients to a more experienced center or having the procedure performed by the most experienced operator. Moreover, the presence of masses or vegetations on the leads significantly increases 1-year and all-cause mortality.
Collapse
Affiliation(s)
- Dorota Nowosielecka
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland
| | | | - Anna Polewczyk
- Department of Physiology, Pathopysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Swietokrzyskie Cardiology Center, 25-736 Kielce, Poland
| | - Dominika Mościcka
- Internal Medicine Residency Program, Tallahassee Memorial HealthCare, Florida State University, 1300 Miccosukee Road Tallahassee, Tallahassee, FL 32308, USA
| | - Agnieszka Nowosielecka
- Department of Internal Medicine and Geriatrics, The A. Falkiewicz Specialist Hospital, 52-114 Wrocław, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| |
Collapse
|
3
|
Mohammad AM, Mohammed HM. Preoperative Echocardiographic Assessment in Elective Surgery Patients: A Cross-Sectional Study From Duhok, Iraqi Kurdistan. Cureus 2024; 16:e70395. [PMID: 39469375 PMCID: PMC11516081 DOI: 10.7759/cureus.70395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/28/2024] [Indexed: 10/30/2024] Open
Abstract
Background and aim Echocardiography plays a pivotal role in the preoperative risk assessment of patients undergoing various surgical procedures. Therefore, we conducted this study to detect various cardiac abnormalities through a preoperative echocardiographic study for cases undergoing elective surgeries in Duhok, Iraqi Kurdistan. Methods This cross-sectional study assessed echocardiographic findings in preoperative patients at Azadi Teaching Hospital, Duhok, Kurdistan Region of Iraq, from 2023 to 2024. The study encompasses 468 adult patients. We gathered clinicodemographic characteristics, indications of referral to a preoperative echo study, and the echocardiographic findings, particularly regional wall motion abnormalities, valvular heart diseases, and heart failure (systolic or diastolic/left ventricular hypertrophy). Results In a cohort of 468 patients, 205 (43.80%) were aged 35-54 years, and 269 (57.48%) were female. Most patients (366; 78.21%) resided in Duhok. Nearly only half of the cases 219 (46.79%) had clear preoperative echostudy indications. A total of 289 (61.74%) had no remarkable echocardiographic findings. Diastolic heart failure was most prevalent at 65 (13.89%). Older cases had more prevalent echo findings in terms of valve dysfunctions and heart failure. Notable associations were found between echocardiographic abnormalities and surgical types, particularly higher regional wall motion abnormalities in genito-urinary system operations (4; 8.16%) and valvular heart disease in orthopedic surgeries (13; 15.85%). Conclusions Echocardiographic abnormalities were remarkably observed in patients aged 65 and older. Many cases had no clear indications for preoperative echo study and hence unremarkable echo findings. More scrutiny is indicated during referral, and focusing on older adults' preoperative cardiac screening is recommended.
Collapse
Affiliation(s)
- Ameen M Mohammad
- Department of Internal Medicine, University of Duhok, Duhok, IRQ
| | | |
Collapse
|
4
|
Silvetti MS, Porco L, Campisi M, Pazzano V, Tamburri I, Saputo FA, Silvetti G, Ravà L, Drago F. Transvenous lead advancement in pediatric pacing to overcome growth-induced lead straightening and stretching. Pacing Clin Electrophysiol 2024; 47:635-641. [PMID: 38552167 DOI: 10.1111/pace.14979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 03/12/2024] [Accepted: 03/15/2024] [Indexed: 04/26/2024]
Abstract
BACKGROUND The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.
Collapse
Affiliation(s)
- Massimo Stefano Silvetti
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Luigina Porco
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Marta Campisi
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Vincenzo Pazzano
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Ilaria Tamburri
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Fabio Anselmo Saputo
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Giacomo Silvetti
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Lucilla Ravà
- Epidemiology Unit, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Fabrizio Drago
- Paediatric Cardiology and Cardiac Arrhythmias Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| |
Collapse
|
5
|
Kutarski A, Jacheć W, Stefańczyk P, Polewczyk A, Kosior J, Nowosielecka D. VDD Lead Extraction-Differences with Other Leads and Practical Tips in Management. J Clin Med 2024; 13:800. [PMID: 38337494 PMCID: PMC10856487 DOI: 10.3390/jcm13030800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/24/2024] [Accepted: 01/26/2024] [Indexed: 02/12/2024] Open
Abstract
Background: VDD (atrial sensing, ventricular sensing/pacing) leads are relatively rarely implanted; therefore, experience in their extraction is very limited. We aimed to investigate whether VDD lead removal may be a risk factor for the increased complexity of transvenous lead extraction (TLE) or major complications. Methods: We retrospectively analyzed 3808 TLE procedures (including 103 patients with VDD leads). Results: If TLE included VDD lead removal, procedure duration (lead dilation time) was prolonged, complicated extractions were slightly more common, and more advanced tools were required. This is partly due to longer implant duration (in patients with VDD systems-135.2 months; systems without VDD leads-109.3 months; p < 0.001), more frequent presence of abandoned leads (all systems containing VDD leads-22.33% and all systems without VDD leads-10.77%), and partly to the younger age of patients with VDD leads (51.74 vs. 57.72 years; p < 0.001, in the remaining patients) at the time of system implantation. VDD lead extraction does not increase the risk of major complications (1.94 vs. 2.34%; p = 0.905). Conclusions: The extraction of VDD leads may be considered a risk factor for increased procedure complexity, but not for major complications. However, this is not a direct result of VDD lead extraction but specific characteristics of the patients with VDD leads. Operator skill and team experience combined with special custom maneuvers can enable favorable results to be achieved despite the specific design of VDD leads, even with older VDD lead models.
Collapse
Affiliation(s)
- Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland;
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Anna Polewczyk
- Department of Medicine and Health Sciences, The John Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, 26-617 Radom, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamosc, 22-400 Zamosc, Poland
| |
Collapse
|
6
|
Kutarski A, Miszczak-Knecht M, Brzezinska M, Birbach M, Lipiński W, Polewczyk AM, Jacheć W, Polewczyk A, Tułecki Ł, Tomków K, Stefańczyk P, Nowosielecka D, Bieganowska K. Transvenous Lead Extraction in Pediatric Patients - Is It the Same Procedure in Children as in Adults? Circ J 2023; 87:990-999. [PMID: 36517020 DOI: 10.1253/circj.cj-22-0542] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/03/2024]
Abstract
BACKGROUND Cardiac implantable electronic devices (CIED) are very rare in the pediatric population. In children with CIED, transvenous lead extraction (TLE) is often necessary. The course and effects of TLE in children are different than in adults. Thus, this study determined the differences and specific characteristics of TLE in children vs. adults. METHODS AND RESULTS A post hoc analysis of TLE data in 63 children (age ≤18 years) and 2,659 adults (age ≥40 years) was performed. The 2 groups were compared with respect to risk factors, procedure complexity, and effectiveness. In children, the predominant pacing mode was a single chamber ventricular system and lead dysfunction was the main indication for lead extraction. The mean implant duration before TLE was longer in children (P=0.03), but the dwell time of the oldest extracted lead did not differ significantly between adults and children. The duration (P=0.006) and mean extraction time per lead (P<0.001) were longer in children, with more technical difficulties during TLE in the pediatric group (P<0.001). Major complications were more common, albeit not significantly, in children. Complete radiographic and procedural success were significantly lower in children (P<0.001). CONCLUSIONS TLE in children is frequently more complex, time consuming, and arduous, and procedural success is more often lower. This is related to the formation of strong fibrous tissue surrounding the leads in pediatric patients.
Collapse
Affiliation(s)
| | | | | | - Mariusz Birbach
- Department of Cardiac Surgery, The Children's Memorial Health Institute
| | - Wojciech Lipiński
- Department of Cardiac Surgery, The Children's Memorial Health Institute
| | | | - Wojciech Jacheć
- Second Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice
| | - Anna Polewczyk
- Department of Physiology, Patophysiology and Clinical Immunology, Jan Kochanowski University, Institute of Medical Sciences
- Department of Cardiac Surgery, Świętokrzyskie Cardiology Center
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital
| | - Konrad Tomków
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital
| | | | | |
Collapse
|
7
|
Gutiérrez Carretero E, Ortiz Carrellán A, Valverde Pérez I, Rodríguez Mora F, Kambiz R, de Alarcón González A. Extracción percutánea de dispositivos de estimulación cardiaca. Uso de las técnicas diagnósticas de imagen para un abordaje seguro. CIRUGIA CARDIOVASCULAR 2023. [DOI: 10.1016/j.circv.2022.12.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
8
|
Nowosielecka D, Jacheć W, Polewczyk A, Tułecki Ł, Stefańczyk P, Kutarski A. "Ghost", a Well-Known but Not Fully Explained Echocardiographic Finding during Transvenous Lead Extraction: Clinical Significance. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12542. [PMID: 36231841 PMCID: PMC9565986 DOI: 10.3390/ijerph191912542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 09/25/2022] [Accepted: 09/26/2022] [Indexed: 06/16/2023]
Abstract
UNLABELLED "Ghosts" are fibrinous remnants that become visible during transvenous lead extraction (TLE). METHODS Data from transoesophageal echocardiography-guided TLE procedures performed in 1103 patients were analysed to identify predisposing risk factors for the development of so-called disappearing ghosts-flying ghosts (FG), or attached to the cardiovascular wall-stable ghosts (SG), and to find out whether the presence of ghosts affected patient prognosis after TLE. RESULTS Ghosts were detected in 44.67% of patients (FG 15.5%, SG 29.2%). The occurrence of ghosts was associated with patient age at first system implantation [FG (OR = 0.984; p = 0.019), SG (OR = 0.989; p = 0.030)], scar tissue around the lead (s) [FG (OR = 7.106; p < 0.001, OR = 1.372; p = 0.011), SG (OR = 1.940; p < 0.001)], adherence of the lead to the cardiovascular wall [FG (OR = 0.517; p = 0.034)] and the number of leads [SG (OR = 1.450; p < 0.002). The presence of ghosts had no impact on long-term survival after TLE in the whole study group [FG HR = 0.927, 95% CI (0.742-1.159); p = 0.505; SG HR = 0.845, 95% CI (0.638-1.132); p = 0.265]. CONCLUSIONS The degree of growth and maturation of scar tissue surrounding the lead was the strongest factor leading to the development of both types of ghosts. The presence of either form of ghost did not affect long-term survival even after TLE indicated for infection.
Collapse
Affiliation(s)
- Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences, Silesian Medical University, 41-800 Zabrze, Poland
| | - Anna Polewczyk
- Institute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, 25-736 Kielce, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| |
Collapse
|
9
|
Polewczyk A, Jacheć W, Nowosielecka D, Tomaszewski A, Brzozowski W, Szczęśniak-Stańczyk D, Duda K, Kutarski A. Tricuspid Valve Damage Related to Transvenous Lead Extraction. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph191912279. [PMID: 36231579 PMCID: PMC9566121 DOI: 10.3390/ijerph191912279] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 09/20/2022] [Accepted: 09/21/2022] [Indexed: 05/29/2023]
Abstract
BACKGROUND Damage to the tricuspid valve (TVD) is now considered either a major or minor complication of the transvenous lead extraction procedure (TLE). As yet, the risk factors and long-term survival after TLE in patients with TVD have not been analyzed in detail. METHODS This post hoc analysis used clinical data of 2631 patients (mean age 66.86 years, 39.64% females) who underwent TLE procedures performed in three high-volume centers. The risk factors and long-term survival of patients with worsening tricuspid valve (TV) function after TLE were analyzed. RESULTS In most procedures (90.31%), TLE had no negative influence on TV function, but in 9.69% of patients, a worsening of tricuspid regurgitation (TR) to varying degrees was noted, including significant dysfunction in 2.54% of patients. Risk factors of TLE relating to severe TVD were: TLE of pacing leads (5.264; p = 0.029), dwell time of the oldest extracted lead (OR = 1.076; p = 0.032), strong connective scar tissue connecting a lead with tricuspid apparatus (OR = 5.720; p < 0.001), and strong connective scar tissue connecting a lead with the right ventricle wall (OR = 8.312; p < 0.001). Long-term survival (1650 ± 1201 [1-5519] days) of patients with severe TR was comparable to patients without tricuspid damage related to TLE. CONCLUSIONS Severe tricuspid valve damage related to TLE is relatively rare (2.5%). The main risk factors for the worsening of TV function are associated with a longer lead dwell time (more often the pacing lead), causing stronger connective tissue scars connecting the lead to the tricuspid apparatus and right ventricle. TVD is unlikely to affect long-term survival after TLE.
Collapse
Affiliation(s)
- Anna Polewczyk
- Institute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Andrzej Tomaszewski
- Department of Cardiology, Medical University of Lublin Poland, 20-059 Lublin, Poland
| | - Wojciech Brzozowski
- Department of Cardiology, Medical University of Lublin Poland, 20-059 Lublin, Poland
| | | | - Krzysztof Duda
- Department of Cardiac Surgery, Masovian Specialistic Hospital, 26-617 Radom, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin Poland, 20-059 Lublin, Poland
| |
Collapse
|
10
|
Martin A, De Bie B, O'Loughlin J. Anaesthesia for extraction of long-term cardiac device leads. BJA Educ 2022; 22:290-294. [PMID: 36097574 PMCID: PMC9463625 DOI: 10.1016/j.bjae.2022.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/27/2022] [Indexed: 10/18/2022] Open
|
11
|
Czajkowski M, Jacheć W, Polewczyk A, Kosior J, Nowosielecka D, Tułecki Ł, Stefańczyk P, Kutarski A. Risk Factors for Lead-Related Venous Obstruction: A Study of 2909 Candidates for Lead Extraction. J Clin Med 2021; 10:jcm10215158. [PMID: 34768676 PMCID: PMC8584439 DOI: 10.3390/jcm10215158] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/10/2021] [Accepted: 11/02/2021] [Indexed: 12/29/2022] Open
Abstract
Background: our knowledge of lead-related venous stenosis/occlusion (LRVSO) remains limited and there is still controversy regarding the risk factors for LRVSO. Venography is mandatory before transvenous lead extraction (TLE). Methods: we performed a retrospective analysis of venograms in 2909 patients (39.43% females, average age 66.90 years) who underwent TLE between 2008 and 2021 at high-volume centers. Results: the severity of LRVSO was likely to be dependent on the number of leads in the system (OR = 1.345; p = 0.003), the number of abandoned leads (OR = 1.965; p < 0.001), the presence of coronary sinus leads (OR = 1.184; p = 0.056), male gender (OR = 1.349; p = 0.003) and patient age at first CIED implantation (OR = 1.008; p = 0.021). The presence of permanent atrial fibrillation (OR = 0.666; p < 0.001) and right ventricular diastolic diameter (OR = 0.978; p = 0.006) showed an inverse correlation with the degree of LRVSO. The combined three-model multivariate analysis provided better prediction of LRSVO using the above-mentioned factors than the CHA2DS2-VASc score. Conclusions: the severity of LRVSO is probably dependent on the mechanical impact of the implanted/abandoned leads on the vein wall, therefore the study has demonstrated the central role of system-/procedure-related risk factors. The thrombotic mechanism may be less important, especially long after implantation, and for this reason the combined prediction model for LRVSO in this study was more effective than the CHA2DS2-VASc score.
Collapse
Affiliation(s)
- Marek Czajkowski
- Department of Cardiac Surgery, Medical University of Lublin, 20-090 Lublin, Poland;
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Science in Zabrze, Medical University of Silesia in Katowice, 41-800 Zabrze, Poland;
| | - Anna Polewczyk
- Department of Physiology, Patophysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, 25-317 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Center of Cardiology, 25-736 Kielce, Poland
- Correspondence: ; Tel.: +48-600024074
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialistic Hospital of Radom, 26-617 Radom, Poland;
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland;
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-090 Lublin, Poland;
| |
Collapse
|
12
|
A Study of Major and Minor Complications of 1500 Transvenous Lead Extraction Procedures Performed with Optimal Safety at Two High-Volume Referral Centers. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph181910416. [PMID: 34639716 PMCID: PMC8508178 DOI: 10.3390/ijerph181910416] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 09/22/2021] [Accepted: 09/29/2021] [Indexed: 11/16/2022]
Abstract
Background: Transvenous lead extraction (TLE) is the preferred management strategy for complications related to cardiac implantable electronic devices. TLE sometimes can cause serious complications. Methods: Outcomes of TLE procedures using non-powered mechanical sheaths were analyzed in 1500 patients (mean age 68.11 years; 39.86% females) admitted to two high-volume centers. Results: Complete procedural success was achieved in 96.13% of patients; clinical success in 98.93%, no periprocedural death occurred. Mean lead dwell time in the study population was 112.1 months. Minor complications developed in 115 (7.65%), major complications in 33 (2.20%) patients. The most frequent minor complications were tricuspid valve damage (TVD) (3.20%) and pericardial effusion that did not necessitate immediate intervention (1.33%). The most common major complication was cardiac laceration/vascular tear (1.40%) followed by an increase in TVD by two or three grades to grade 4 (0.80%). Conclusions: Despite the long implant duration (112.1 months) satisfying results without procedure-related death can be obtained using mechanical tools. Lead remnants or severe tricuspid regurgitation was the principal cause of lack of clinical and procedural success. Worsening TR(Tricuspid regurgitation) (due to its long-term consequences), but not cardiac/vascular wall damage; is still the biggest TLE-related problem; when non-powered mechanical sheaths are used as first-line tools.
Collapse
|
13
|
The Influence of Lead-Related Venous Obstruction on the Complexity and Outcomes of Transvenous Lead Extraction. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18189634. [PMID: 34574558 PMCID: PMC8465436 DOI: 10.3390/ijerph18189634] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/04/2021] [Accepted: 09/09/2021] [Indexed: 11/17/2022]
Abstract
Background: Little is known about lead-related venous stenosis/occlusion (LRVSO), and the influence of LRVSO on the complexity and outcomes of transvenous lead extraction (TLE) is debated in the literature. Methods: We performed a retrospective analysis of venograms from 2909 patients who underwent TLE between 2008 and 2021 at a high-volume center. Results: Advanced LRVSO was more common in elderly men with a high Charlson comorbidity index. Procedure duration, extraction of superfluous leads, occurrence of any technical difficulty, lead-to-lead binding, fracture of the lead being extracted, need to use alternative approach and lasso catheters or metal sheaths were found to be associated with LRVSO. The presence of LRVSO had no impact on the number of major complications including TLE-related tricuspid valve damage. The achievement of complete procedural or clinical success did not depend on the presence of LRVSO. Long-term mortality, in contrast to periprocedural and short-term mortality, was significantly worse in the groups with LRSVO. Conclusions: LRVSO can be considered as an additional TLE-related risk factor. The effect of LRVSO on major complications including periprocedural mortality and on short-term mortality has not been established. However, LRVSO has been associated with poor long-term survival.
Collapse
|
14
|
Wang L, Hai T, Feng Y, Han Q, Li Y, Ju H, Jiang Y, Li X, Ze F, Liu G, Jiang L. The clinical role of transesophageal echocardiography during transvenous lead extraction. Echocardiography 2021; 38:1552-1557. [PMID: 34510520 DOI: 10.1111/echo.15171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Revised: 06/19/2021] [Accepted: 07/20/2021] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND Transesophageal echocardiography (TEE) is commonly used during cardiothoracic procedures. TEE has also become standard during transvenous lead extraction (TLE) procedures, but its effect and role have not been optimally defined. The goal of this study is to identify how TEE was used during TLE at our institute and review its utility. METHODS We retrospectively reviewed high-risk patients undergoing TLE, for whom more complications during extraction procedures, from June 2012 to September 2020. The patients were divided into TEE group and non-TEE group according to real-time TEE monitoring. We compared the rate of procedural success, complications between two groups and concluded the clinical utility of TEE during TLE. RESULTS A total of 195 patients were included (105 in TEE group vs 90 in non-TEE group), the rate of procedure success (97.8% vs 96.5%, p = 0.41) and complications during extraction (8.6% vs 12.2%, p = 0.40, major complication 5.7% vs 12.2%, p = 0.11, minor complication 2.9% vs 0%, p = 0.30) were comparable. In TEE group, 12 patients (11.4%) received following benefits: altering surgical plans, guiding subsequent therapy strategies, and rapidly diagnosing complications, moreover no complications occurred from TEE. CONCLUSIONS This study demonstrates that real-time monitoring by TEE cannot change the rate of procedural success and complication during TLE; however, TEE provides valuable information to instruct clinical therapy and improves the safety of TLE.
Collapse
Affiliation(s)
- Lu Wang
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - Ting Hai
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - Yi Feng
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - QiaoYu Han
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - YaRu Li
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - Hui Ju
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - Yan Jiang
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| | - XueBin Li
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Beijing, China
| | - Feng Ze
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Beijing, China
| | - Gang Liu
- Department of Cardiac Surgery, Peking University People's Hospital, Beijing, China
| | - LuYang Jiang
- Department of Anesthesiology, Peking University People's Hospital, Beijing, China
| |
Collapse
|
15
|
Tułecki Ł, Polewczyk A, Jacheć W, Nowosielecka D, Tomków K, Stefańczyk P, Kosior J, Duda K, Polewczyk M, Kutarski A. Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18179100. [PMID: 34501689 PMCID: PMC8431163 DOI: 10.3390/ijerph18179100] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/22/2021] [Accepted: 08/25/2021] [Indexed: 01/28/2023]
Abstract
Background: Transvenous lead extraction (TLE) is a relatively safe procedure, but it may cause severe complications such as cardiac/vascular wall tear (CVWT) and tricuspid valve damage (TVD). Methods: The risk factors for CVWT and TVD were examined based on an analysis of data of 1500 extraction procedures performed in two high-volume centers. Results: The total number of major complications was 33 (2.2%) and included 22 (1.5%) CVWT and 12 (0.8%) TVD (with one case of combined complication). Patients with hemorrhagic complications were younger, more often women, less often presenting low left ventricular ejection fraction (LVEF) and those who received their first cardiac implantable electronic device (CIED) earlier than the control group. A typical patient with CVWT was a pacemaker carrier, having more leads (including abandoned leads and excessive loops) with long implant duration and a history of multiple CIED-related procedures. The risk factors for TVD were similar to those for CVWT, but the patients were older and received their CIED about nine years earlier. Any form of tissue scar and technical problems were much more common in the two groups of patients with major complications. Conclusions: The risk factors for CVWT and TVD are similar, and the most important ones are related to long lead dwell time and its consequences for the heart (various forms of fibrotic scarring). The occurrence of procedural complications does not affect long-term survival in patients undergoing lead extraction.
Collapse
Affiliation(s)
- Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (Ł.T.); (K.T.)
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology Collegium Medicum, The Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, 25-369 Kielce, Poland
- Correspondence:
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Silesian Medical University, 41-808 Zabrze, Poland;
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Konrad Tomków
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (Ł.T.); (K.T.)
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamość, Poland; (D.N.); (P.S.)
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialist Hospital of Radom, 26-617 Radom, Poland;
| | - Krzysztof Duda
- Department of Cardiac Surgery,
Masovian Specialist Hospital of Radom, 26-617 Radom, Poland;
| | - Maciej Polewczyk
- Faculty of Medicine and Health Studies, Jan Kochanowski University, 25-369 Kielce, Poland;
| | - Andrzej Kutarski
- Department of Cardiology, Medical University of Lublin, 20-509 Lublin, Poland;
| |
Collapse
|
16
|
Stefańczyk P, Nowosielecka D, Tułecki Ł, Tomków K, Polewczyk A, Jacheć W, Kleinrok A, Borzęcki W, Kutarski A. Transvenous Lead Extraction without Procedure-Related Deaths in 1000 Consecutive Patients: A Single-Center Experience. Vasc Health Risk Manag 2021; 17:445-459. [PMID: 34385818 PMCID: PMC8352641 DOI: 10.2147/vhrm.s318205] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 06/17/2021] [Indexed: 11/23/2022] Open
Abstract
Background Transvenous lead extraction (TLE) is now a first-line technique for the treatment of complications related to cardiac implantable electronic devices. The aim of the study was to demonstrate that it is possible to safely perform difficult TLE procedures with a maximum reduction of peri-procedural major complications. Methods A total of 1000 consecutive patients undergoing TLE in a single high-volume center from 2016 to 2019 were studied. All procedures were performed in a hybrid room or operating room by a specialized TLE team. TLE was performed under general anesthesia and monitored by transesophageal echocardiography, and the operating room was suitably equipped for immediate surgical intervention. The effectiveness and safety of the procedures were assessed, with particular emphasis on major complications. Results In all, 1952 leads with the mean implant duration of 111.7 ± 77.6 months had been extracted. Complete procedural success of patients was achieved in 95.9% and clinical success in 99.1%. Major complications, predominantly cardiac tamponade (63.3%), occurred in 22 patients (2.2%). Rapid diagnosis and immediate intervention were the key to a 100% survival in patients with this complication. Conclusion Performing procedures in a hybrid operating room under general anesthesia in the presence of a cardiac surgeon and with the use of transesophageal echocardiography significantly improves the safety of transvenous lead extraction.
Collapse
Affiliation(s)
- Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Konrad Tomków
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology, and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, Kielce, Poland.,Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, Kielce, Poland
| | - Wojciech Jacheć
- Silesian Medical University, 2nd Department of Cardiology, Zabrze, Poland
| | - Andrzej Kleinrok
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland.,Medical College, Department of Physiotherapy, University of Information Technology and Management, Rzeszów, Poland
| | - Wojciech Borzęcki
- Department of Cardiology, The Pope John Paul II Province Hospital of Zamość, Zamość, Poland
| | | |
Collapse
|
17
|
Prognostic Value of Preoperative Echocardiographic Findings in Patients Undergoing Transvenous Lead Extraction. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18041862. [PMID: 33672931 PMCID: PMC7918219 DOI: 10.3390/ijerph18041862] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 01/31/2021] [Accepted: 02/11/2021] [Indexed: 01/10/2023]
Abstract
(1) Background: In patients referred for transvenous lead extraction (TLE) transesophageal echocardiography (TEE) often reveals abnormalities related to chronically indwelling endocardial leads. The purpose of this study was to determine whether the results of pre-operative TEE might influence the long-term prognosis. (2) Methods: We analyzed data from 936 TEE examinations performed at a high volume center in patients referred for TLE from 2015 to 2019. The follow-up was 566.2 ± 224.5 days. (3) Results: Multivariate analysis of TEE parameters showed that vegetations (HR = 2.631 [1.738–3.983]; p < 0.001) and tricuspid valve (TV) dysfunction unrelated to the endocardial lead (HR = 1.481 [1.261–1.740]; p < 0.001) were associated with increased risk for long-term mortality. Presence of fibrous tissue binding sites between the lead and the superior vena cava (SVC) and/or right atrium (RA) wall (HR = 0.285; p = 0.035), presence of penetration or perforation of the lead through the cardiac wall up to the epicardium (HR = 0.496; p = 0.035) and presence of excessive lead loops (HR = 0.528; p = 0.026) showed a better prognosis. After adjustment the statistical model with recognized poor prognosis factors only vegetations were confirmed as a risk factor (HR = 2.613; p = 0.039). A better prognosis was observed in patients with fibrous tissue binding sites between the lead and the superior vena cava (SVC) and/or right atrium (RA) wall (HR = 0.270; p = 0.040). (4) Conclusions: Non-modifiable factors may have a negative influence on long-term survival after TLE. Various forms of connective tissue overgrowth and abnormal course of the leads modifiable by TLE can be a factor of better prognosis after TLE.
Collapse
|