1
|
Wu F, Khan AA, Klimovskij M, Harshen R. The effect of antiplatelet therapy and oral anticoagulants on the accuracy of faecal immunochemical testing. Ann R Coll Surg Engl 2024; 106:521-527. [PMID: 38478034 PMCID: PMC11214854 DOI: 10.1308/rcsann.2024.0015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/30/2024] [Indexed: 07/02/2024] Open
Abstract
INTRODUCTION Faecal immunochemical testing (FIT) has been adopted to identify patients requiring further investigations on the colorectal cancer (CRC) referral pathway. We aimed to investigate the effect of antiplatelet and anticoagulant drugs on the accuracy of FIT results. METHODS This observational study categorised patients with suspected CRC symptoms, who completed both FIT and colonic investigations, into two groups (control and exposed) based on their use of antiplatelet and anticoagulant drugs. Two-by-two tables and receiver operating characteristic (ROC) curve analysis were used to determine accuracy. RESULTS A total of 928 patients were divided into a control (n=683) and an exposed group (n=245). A nonsignificant higher proportion of patients tested positive in the exposed group (24.1% vs 18.4%, p=0.063). For detection of CRC, improved sensitivity of 87% vs 81.2%, specificity of 84.8% vs 79.9% and negative predictive value of 99.2% vs 98.3% was calculated in the control vs exposed groups, respectively. The positive predictive value was comparable between the two groups (21.4% vs 22% in the control and exposed groups, respectively). In ROC analysis, there was no difference between the groups (AUC 90% vs 87%, p=0.56). The use of antiplatelet and anticoagulant drugs did not increase the risk of positive FIT results on multivariate logistic regression analysis. CONCLUSIONS FIT accuracy for CRC detection remained unaffected despite more patients testing positive in the exposed group. FIT should be considered a supplementary tool for triage. Antiplatelet and anticoagulant drugs do not need to be discontinued before collection of FIT.
Collapse
Affiliation(s)
- F Wu
- East Sussex Hospitals NHS Trust, UK
| | - AA Khan
- East Kent Hospitals University NHS Trust, UK
| | | | | |
Collapse
|
2
|
Han Z, Nan X, Ma M, Zhou R, Wang P, Liu J, Li Y, Li Y. Effect of aspirin, warfarin, and proton-pump inhibitors on performance of fecal immunochemical test in colorectal cancer screening: a systematic review and meta-analysis. Clin Exp Med 2023; 23:4355-4368. [PMID: 37804359 DOI: 10.1007/s10238-023-01196-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 09/14/2023] [Indexed: 10/09/2023]
Abstract
This study aims to investigate the impact of antithrombotic agents and proton-pump inhibitors (PPIs) on fecal immunochemical test (FIT). PubMed, EMBASE, Web of Science, Cochrane Central, and Google Scholar were searched from inception until September 3, 2023. Studies comparing the diagnostic performance of FIT between medicine users and non-users in average-risk colorectal cancer screening populations were included. Pooled sensitivity, specificity, and positive predictive values (PPVs) for advanced neoplasia (AN) of FIT were compared by reporting pooled odds ratios (ORs) with 95% confidence intervals (CIs) using a random-effects model. Twenty-two studies enrolling 5,572,367 individuals were included. For aspirin, pooled sensitivity and specificity for AN were 57.2% and 88.4% in users versus 60.2% and 93.2% in non-users; while pooled ORs were 1.49 (95% CI 0.89-2.48, P = 0.13) and 0.72 (95% CI 0.62-0.83, P < 0.001), respectively. In subgroup analysis, there was no difference in sensitivity and specificity between the two groups at the cutoff of 20 μg Hb/g (P = 0.57 and 0.29, respectively) but a significantly lower specificity in users compared with non-users at lower cutoffs (P < 0.001). Moreover, a significantly lower PPVAN in users compared with non-users was observed after matching age and sex confounders (P = 0.001). Warfarin had no significant influence on PPVAN of FIT (P = 0.43). PPIs were associated with a significantly lower PPVAN in users (P < 0.001). Aspirin use was associated with lower specificity and PPV of FIT. Aspirin discontinuation before FIT to reduce false-positive results should be interpreted with caution given concerns about cardiovascular events. Increasing cutoff values of FIT in aspirin users may be another possible approach. Additionally, warfarin withdrawal before FIT is unnecessary but PPIs withdrawal before FIT is recommended to reduce false-positive results.
Collapse
Affiliation(s)
- Zhongxue Han
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Xueping Nan
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Mingjun Ma
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Ruchen Zhou
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Peizhu Wang
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Jing Liu
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Yanqing Li
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Yueyue Li
- Department of Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, 107 Wenhuaxi Road, Jinan, 250012, Shandong Province, China.
- Laboratory of Translational Gastroenterology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China.
- Robot Engineering Laboratory for Precise Diagnosis and Therapy of GI Tumor, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China.
| |
Collapse
|
3
|
Pang SJ, Lin ZP, Sun Z, Zhang Y, Yuan ZG, Yang N. Impact of antithrombotic drugs on the accuracy of fecal occult blood testing for advanced colorectal neoplasia screening: a meta-analysis and systematic review. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2023; 61:297-306. [PMID: 35580620 DOI: 10.1055/a-1817-3925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND The current meta-analysis was conducted to determine whether antithrombotic drug use would affect the diagnostic accuracy of fecal occult blood testing for advanced colorectal neoplasia. METHODS Articles published between 2000 and 2019 were systematically retrieved and screened according to the inclusion and exclusion criteria by two reviewers independently. Pooled analyses were conducted with a fixed-effect model if no apparent heterogeneity (I2 ≥ 50%) was found between studies; otherwise, the random effects model would be used. Sensitivity analysis and subgroup analysis were also conducted using Review Manager 5.3. RESULTS Pooled analysis revealed that aspirin and nonsteroidal anti-inflammatory drugs were associated with a decrease in the positive predictive value of fecal occult blood testing for advanced colorectal neoplasia screening, with a RR of 0.89 (95% CI: 0.84-0.94) and 0.88 (95% CI: 0.84-0.93, p<0.001) respectively. Subgroup analysis based on data limited to high-quality studies, fecal immunochemical testing, or in Caucasians also showed that the use of aspirin/NSAID drugs decreased the accuracy for advanced colorectal neoplasia screening. CONCLUSION Aspirin/NSAIDs and direct oral anticoagulants rather than warfarin may decrease the diagnostic accuracy of fecal occult blood testing for advanced colorectal neoplasia screening.
Collapse
Affiliation(s)
- Shu-Jie Pang
- Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai, China
| | - Zhi-Peng Lin
- Department of Hepatobiliary Surgery, The 940th Hospital of PLA Joint Logistics Support Force, Lanzhou, China.,Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai, China
| | - Zhe Sun
- Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai, China
| | - Yu Zhang
- Tongji Hospital, School of Medicine, Tongji University, Shanghai, China
| | - Zhen-Gang Yuan
- Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai, China
| | - Ning Yang
- Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai, China
| |
Collapse
|
4
|
Abstract
Colorectal cancer (CRC) is the second-leading cause of cancer death in the United States. Screening reduces CRC incidence and mortality. 2021 US Preventive Service Task Force (USPSTF) guidelines and available evidence support routine screening from ages 45 to 75, and individualized consideration of screening ages 76 to 85. USPSTF guidelines recommend annual guaiac fecal occult blood testing, annual fecal immunochemical testing (FIT), annual to every 3-year multitarget stool DNA-FIT, every 5-year sigmoidoscopy, every 10-year sigmoidoscopy with annual FIT, every 5-year computed tomographic colonography, and every 10-year colonoscopy as options for screening. The "best test is the one that gets done."
Collapse
Affiliation(s)
- Samir Gupta
- GI Section, VA San Diego Healthcare System, Department of Gastroenterology, University of California San Diego, 3350 La Jolla Village Drive, MC 111D, San Diego, CA 92161, USA.
| |
Collapse
|
5
|
Jung YS, Im E, Park CH. Impact of antiplatelet agents and anticoagulants on the performance of fecal immunochemical tests: a systematic review and meta-analysis. Surg Endosc 2022; 36:4299-4311. [PMID: 34716478 DOI: 10.1007/s00464-021-08774-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 10/12/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND Antithrombotic agents may increase the bleeding tendency and affect the performance of fecal immunochemical test (FIT). We aimed to evaluate the impact of antithrombotic agents on the performance of FIT through a systematic review and meta-analysis. METHODS All relevant studies published between January 1980 and September 2020 that examined the diagnostic performance of FIT were searched through MEDLINE, EMBASE, and Cochrane Library databases. We performed a meta-analysis for the positive predictive value (PPV) of FIT for detecting advanced colorectal neoplasia (ACRN) or colorectal cancer (CRC) according to the administration of antithrombotic agents including aspirin, antiplatelet agents, and oral anticoagulants (OACs). RESULTS Thirteen studies with 27,518 patients were included. Of these, 11 studies with data required for the calculation of pooled PPV were included in the meta-analysis. The pooled PPV of FIT for detecting ACRN was significantly lower in antithrombotic agent users than in non-users (odds ratio [OR] [95% confidence interval [CI]]: aspirin, 0.82 [0.68-0.99]; antiplatelet agents, 0.82 [0.69-0.96]; OACs, 0.66 [0.52-0.84]). For detecting CRC, antithrombotic agent use tended to be associated with a reduced PPV (aspirin, 0.76 [0.51-1.14]; antiplatelet agents, 0.73 [0.52-1.02]; OACs, 0.60 [0.25-1.44]). In the subgroup analysis, a FIT cutoff value of 15 μg Hb/g feces tended to be associated with lower PPVs compared to a value of 20 μg Hb/g feces in antithrombotic agent users. CONCLUSIONS Aspirin, antiplatelet agents, and OACs significantly lowered the PPV of FIT for detecting ACRN. These drugs may increase the false-positive of FIT.
Collapse
Affiliation(s)
- Yoon Suk Jung
- Department of Internal Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Eui Im
- Division of Cardiology, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine and Cardiovascular Center, Yongin, Republic of Korea
| | - Chan Hyuk Park
- Department of Internal Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, 153 Gyeongchun-ro, Guri, 11923, Republic of Korea.
| |
Collapse
|
6
|
False-positive fecal immunochemical test results in colorectal cancer screening and gastrointestinal drug use. Int J Colorectal Dis 2021; 36:1861-1869. [PMID: 33982138 DOI: 10.1007/s00384-021-03947-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/27/2021] [Indexed: 02/04/2023]
Abstract
PURPOSE The study aimed to determine the influence of drug treatments (proton pump inhibitors [PPIs] combined with other drugs) on the false-positive (FP) rate in the fecal immunochemical test (FIT). METHODS Patients undergoing colonoscopy in the setting of a CRC screening program due to a positive FIT result were included prospectively. Demographic data and drug intake of PPIs, antiplatelet therapy (APA), anticoagulants, selective serotonin reuptake inhibitors (SSRIs), and nonsteroidal anti-inflammatory drugs (NSAIDs) were collected. An FP FIT result was considered normal colonoscopy or with nonneoplastic pathology (NNP). Logistic regression models were used to evaluate the effect of these drugs on the rate of FP FIT results. RESULTS We included 515 patients, and 59% (304/515) were males. The rate of FP FIT results was 48% (249/515). Study drug use was higher in patients > 60 years old and females than in those < 60 years old and males (p < 0.001 and p = 0.049, respectively). Multivariate logistic regression revealed that female sex (OR = 2.7 95% CI 1.9-3.9), NNP (OR = 1.5 95% CI 1.1-2.2), and the use of any of the study drugs (OR = 1.4 95% CI 0.9-2.0) were independent risk factors for FP FIT results. The risk of FP FIT results was significantly higher in PPI users than in nonusers (OR = 1.8 95% CI 1.1-2.9), specifically when PPIs were combined with other drugs (OR = 2.01 95% CI 1.1-3.6) only in men. CONCLUSION Female sex, NNP, and PPIs combined with other drugs in males were identified as independent risk factors for FP FIT results.
Collapse
|
7
|
Use of Antiplatelet Agents Decreases the Positive Predictive Value of Fecal Immunochemical Tests for Colorectal Cancer but Does Not Affect Their Sensitivity. J Pers Med 2021; 11:jpm11060497. [PMID: 34205974 PMCID: PMC8227279 DOI: 10.3390/jpm11060497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 05/19/2021] [Accepted: 05/25/2021] [Indexed: 11/17/2022] Open
Abstract
Previous studies have evaluated the effects of antithrombotic agents on the performance of fecal immunochemical tests (FITs) for the detection of colorectal cancer (CRC), but the results were inconsistent and based on small sample sizes. We studied this topic using a large-scale population-based database. Using the Korean National Cancer Screening Program Database, we compared the performance of FITs for CRC detection between users and non-users of antiplatelet agents and warfarin. Non-users were matched according to age and sex. Among 5,426,469 eligible participants, 768,733 used antiplatelet agents (mono/dual/triple therapy, n = 701,683/63,211/3839), and 19,569 used warfarin, while 4,638,167 were non-users. Among antiplatelet agents, aspirin, clopidogrel, and cilostazol ranked first, second, and third, respectively, in terms of prescription rates. Users of antiplatelet agents (3.62% vs. 4.45%; relative risk (RR): 0.83; 95% confidence interval (CI): 0.78–0.88), aspirin (3.66% vs. 4.13%; RR: 0.90; 95% CI: 0.83–0.97), and clopidogrel (3.48% vs. 4.88%; RR: 0.72; 95% CI: 0.61–0.86) had lower positive predictive values (PPVs) for CRC detection than non-users. However, there were no significant differences in PPV between cilostazol vs. non-users and warfarin users vs. non-users. For PPV, the RR (users vs. non-users) for antiplatelet monotherapy was 0.86, while the RRs for dual and triple antiplatelet therapies (excluding cilostazol) were 0.67 and 0.22, respectively. For all antithrombotic agents, the sensitivity for CRC detection was not different between users and non-users. Use of antiplatelet agents, except cilostazol, may increase the false positives without improving the sensitivity of FITs for CRC detection.
Collapse
|
8
|
Ibuka T, Adachi S, Horibe Y, Ohno T, Mabuchi M, Suzuki Y, Yamauchi O, Takada E, Iwama M, Saito K, Arao M, Takai K, Araki H, Shimizu M. Effects of antithrombotic drugs on the results of fecal immunochemical test in colorectal neoplasms screening. Sci Rep 2021; 11:4348. [PMID: 33623065 PMCID: PMC7902607 DOI: 10.1038/s41598-021-83007-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 01/22/2021] [Indexed: 12/12/2022] Open
Abstract
Fecal immunochemical test (FIT) is widely used as a colorectal cancer screening tool. Antithrombotic drugs may affect the screening performance of FIT for colorectal tumors. The aim of this study was to clarify the effect of antithrombotic agents on FIT accuracy in screening for colorectal neoplasms. This retrospective study enrolled a total of 758 patients who underwent both FIT and total colonoscopy. The effect of antithrombotic drugs on FIT accuracy in detecting colorectal neoplasms (CN), including colorectal cancer (CRC), advanced adenoma (AA), and non-advanced adenoma (NAA), was examined. Of the 758 patients, 144 (19%) received antithrombotic drugs (administration group). In administration group, 61/144 (42%) cases had CN [CRC:14, AA:15, NAA:32] and 217/614 (35%) cases had CN (CRC:43, AA:56, NAA:118) in non-administration group. The prevalence of CN was not significantly different between the two groups (p = 0.1157). There was no significant difference in sensitivity or specificity of the detection of all types of CN with or without taking antithrombotic drugs. Neither the positive predictive value nor negative predictive value of FIT was affected by antithrombotic drug administration. Taking antithrombotic drugs may not have a large impact on sensitivity, specificity, positive predictive value, or negative predictive value of FIT in screening for CN.
Collapse
Affiliation(s)
- Takashi Ibuka
- Division for Regional Cancer Control, Gifu University Graduate School of Medicine, Gifu, Japan.,Department of Gastroenterology, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Seiji Adachi
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan.
| | - Yohei Horibe
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Tomohiko Ohno
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Masatoshi Mabuchi
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Yusuke Suzuki
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Osamu Yamauchi
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Eri Takada
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Midori Iwama
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Koshiro Saito
- Department of Gastroenterology/Internal Medicine, Gihoku Kosei Hospital, 1187-3 Takatomi, Yamagata, 501-2105, Japan
| | - Masamichi Arao
- Department of Gastroenterology, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Koji Takai
- Division for Regional Cancer Control, Gifu University Graduate School of Medicine, Gifu, Japan.,Department of Gastroenterology, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Hiroshi Araki
- Department of Gastroenterology, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Masahito Shimizu
- Department of Gastroenterology, Gifu University Graduate School of Medicine, Gifu, Japan
| |
Collapse
|
9
|
Impact of antithrombotics on the fecal immunochemical test for colorectal cancer screening : a multi-center Belgian experience. Acta Gastroenterol Belg 2021; 84:19-24. [PMID: 33639689 DOI: 10.51821/84.1.349] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Background Impact of antithrombotics on the fecal immunochemical test (FIT) for colorectal cancer (CRC) screening remains unclear. Methods Patients undergoing colonoscopy for positive FIT in 2015 were assessed at 3 Belgian centers. Significant findings were advanced polyps (AP) (sessile serrated, tubular or villous adenomas >1cm or high-grade dysplasia) and CRC. False positive FIT and detection of AP/CRC with antithrombotics were calculated. Results 510 patients (64% male, median (IQR) age 63.2 (60.2 - 66.4) years) were included. Colorectal pathology in 371/510 (73%) was associated with male gender (70% vs. 48% ; p= .0001) and family history (16% vs. 8% ; p= .02). Antithrombotics in 125/510 (25%) were associated with male gender (78% vs. 59% ; p= .0001), older age (65.2 (62.2-70.3) vs. 62.3 (58.7-66.3) years ; p= .0001) and GI-symptoms (18% vs. 11% ; p= .04). False positive FIT (25% vs. 28% ; p= .52) and detection of AP (42% vs. 36% ; p=.27) or CRC (6% vs. 5% ; p= .69) were similar in patients with vs. no antithrombotics. Use of antithrombotics did not predict a higher chance of colorectal pathology after adjusting for confounders. Conclusion Although antithrombotics were prescribed more frequently in male and older patients, detection of AP/CRC was similar. Despite increased GI symptoms, false positive FIT was similar with antithrombotics.
Collapse
|
10
|
Nieuwenburg SAV, Vuik FER, Kruip MJHA, Kuipers EJ, Spaander MCW. Effect of anticoagulants and NSAIDs on accuracy of faecal immunochemical tests (FITs) in colorectal cancer screening: a systematic review and meta-analysis. Gut 2019; 68:866-872. [PMID: 29871970 DOI: 10.1136/gutjnl-2018-316344] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 04/18/2018] [Accepted: 05/10/2018] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Most colorectal cancer (CRC) screening programmes are nowadays based on faecal immunochemical testing (FIT). Eligible subjects often use oral anticoagulants (OACs) or non-steroidal anti-inflammatory drugs (NSAIDs), which could possibly stimulate bleeding from both benign and premalignant lesions in the colon. The aim of this meta-analysis was to study the effect of OACs and NSAIDs use on FIT performance. DESIGN A systematic search was conducted until June 2017 to retrieve studies from PubMed, Embase, MEDLINE, Web of science, Cochrane Central and Google Scholar. Studies were included when reporting on FIT results in users versus non-users of OACs and/or NSAIDs in average risk CRC screening populations. Primary outcome was positive predictive value for advanced neoplasia (PPVAN) of FIT in relation to OACs/NSAIDs use. Values were obtained by conducting random-effect forest plots. RESULTS Our literature search identified 2022 records, of which 8 studies were included. A total of 3563 participants with a positive FIT were included. Use of OACs was associated with a PPVAN of 37.6% (95% CI 33.9 to 41.4) compared with 40.3% (95% CI 38.5 to 42.1) for non-users (p=0.75). Pooled PPVAN in aspirin/NSAID users was 38.2% (95% CI 33.8 to 42.9) compared with 39.4% (95% CI 37.5 to 41.3) for non-users (p=0.59). CONCLUSION FIT accuracy is not affected by OACs and aspirin/NSAIDs use. Based on the current literature, withdrawal of OACs or NSAIDs before FIT screening is not recommended. Future studies should focus on duration of use, dosage and classes of drugs in association with accuracy of FIT to conduct more specific guideline recommendations.
Collapse
Affiliation(s)
- Stella A V Nieuwenburg
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Fanny E R Vuik
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Marieke J H A Kruip
- Department of Hematology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Ernst J Kuipers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Manon C W Spaander
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
11
|
Participant-Related Risk Factors for False-Positive and False-Negative Fecal Immunochemical Tests in Colorectal Cancer Screening: Systematic Review and Meta-Analysis. Am J Gastroenterol 2018; 113:1778-1787. [PMID: 30158713 PMCID: PMC6768609 DOI: 10.1038/s41395-018-0212-7] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 06/29/2018] [Indexed: 02/06/2023]
Abstract
OBJECTIVES Colorectal cancer (CRC) screening using fecal immunochemical tests (FIT) may reduce CRC-related mortality but its effectiveness is influenced by the limited accuracy of FIT. Identifying individuals at increased risk of a false FIT result could improve screening, but the available evidence is conflicting. We performed a systematic review and meta-analysis on risk factors for false-positive and false-negative FIT results in CRC screening. METHODS A systematic search in MEDLINE, EMBASE, and Cochrane Library identified publications (before 29 January 2017) on risk factors (known at time of FIT invitation) associated with false FIT results (presence/absence of advanced neoplasia) in a CRC screening setting. Risk of bias was assessed using QUIPS. In meta-analysis, summary relative risk ratios and corresponding 95% confidence intervals were calculated for each risk factor. RESULTS Of 518 records identified, 14 studies with 54,499 participants in total were included for analysis. In meta-analysis, male sex was associated with a significantly lower risk of false-positivity (RR 0.84, CI 0.74-0.94), whereas participants using non-steroidal anti-inflammatory drugs (NSAIDs) had a higher risk (RR 1.16, CI 1.06-1.27). The use of anticoagulants was most frequently studied, without a significant effect on FIT positivity. Males (RR 1.83, CI 1.53-2.19), participants with a family history for CRC (RR 1.61, CI 1.19-2.15), hyperglycemia (RR 1.29, CI 1.02-1.65), hypertension (RR 1.50, CI 1.14-1.98), obesity (RR 1.38, CI 1.11-1.71), and (former) smokers (RR 1.93, CI 1.52-2.45) were all at significantly higher risk for false-negative results. Age was not found to have a systematic effect on either FIT false-positivity or false-negativity in meta-analysis. CONCLUSIONS Multiple risk factors, known at time of FIT invitation, are associated with false FIT results in CRC screening. This information can be used to identify populations risking false reassurance after a negative result or unnecessary colonoscopy after a positive result, and to further optimize CRC screening effectiveness.
Collapse
|
12
|
Teixeira CR, Bonotto ML, Lima JP, Figueiredo LF, Conrado L, Frasca C. Clinical impact of the immunochemical fecal occult blood test for colorectal cancer screening in Brazil. Ann Gastroenterol 2017; 30:442-445. [PMID: 28655982 PMCID: PMC5479998 DOI: 10.20524/aog.2017.0151] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Accepted: 03/03/2017] [Indexed: 11/24/2022] Open
Abstract
Background Colorectal cancer (CRC) screening programs based on the fecal occult blood test (FOBT) reduce CRC mortality. We carried out an observational prospective study to determine the accuracy of immunochemical FOBTs for the detection of CRC in individuals at average risk for the disease. Methods This population-based study was performed between April 2015 and January 2016 in two gastroenterology referral centers in Southern Brazil. It included 1039 average-risk volunteers aged 50-75 years who were symptom-free for colonic disease. Participants underwent OC-Light immunochemical fecal occult blood test (i-FOBT, EIKEN chemical Co., Tokyo, Japan) as well as screening colonoscopy. Results Nine hundred forty-eight (91.2%) of the 1039 participants completed and returned the i-FOBT (95% confidence interval [CI] 89.4-92.9). Among the 73 participants with a positive i-FOBT who underwent colonoscopy, advanced CRC was detected in 9 (12.3%). Two (2.7%) early CRCs, 7 (9.5%) high-grade dysplasia adenomas and 25 (34.2%) low-grade dysplasia adenomas were also diagnosed. Among the 243 negative i-FOBT cases who underwent colonoscopy, one (0.4%) advanced CRC and 91 (37.6%) low-grade dysplasia adenomas were detected. The detection rate of CRC considering the whole screened population (n=1039) was 1.05% (11/1039). Conclusions The i-FOBT test in the CRC screening programs in Brazil showed a high compliance and high detection rates for cancers and high-risk adenomas. The i-FOBT test is feasible for CRC screening in an average-risk population.
Collapse
Affiliation(s)
- Cláudio R Teixeira
- Department of Endoscopy, Moinhos de Vento Hospital (Cláudio R. Teixeira, Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca)
| | - Michele L Bonotto
- Department of Endoscopy, Moinhos de Vento Hospital (Cláudio R. Teixeira, Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca).,Gastroenterology Fundation of Rio Grande do Sul, Fugast, Endoscopy Unit (Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca), Brazil
| | - Júlio P Lima
- Department of Endoscopy, Moinhos de Vento Hospital (Cláudio R. Teixeira, Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca).,Gastroenterology Fundation of Rio Grande do Sul, Fugast, Endoscopy Unit (Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca), Brazil
| | - Luciana F Figueiredo
- Department of Endoscopy, Moinhos de Vento Hospital (Cláudio R. Teixeira, Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca).,Gastroenterology Fundation of Rio Grande do Sul, Fugast, Endoscopy Unit (Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca), Brazil
| | - Leonardo Conrado
- Department of Endoscopy, Moinhos de Vento Hospital (Cláudio R. Teixeira, Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca).,Gastroenterology Fundation of Rio Grande do Sul, Fugast, Endoscopy Unit (Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca), Brazil
| | - Carlos Frasca
- Department of Endoscopy, Moinhos de Vento Hospital (Cláudio R. Teixeira, Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca).,Gastroenterology Fundation of Rio Grande do Sul, Fugast, Endoscopy Unit (Michele L. Bonotto, Júlio P. Lima, Luciana F. Figueiredo, Leonardo Conrado, Carlos Frasca), Brazil
| |
Collapse
|