1
|
Ranking the environmental factors of indoor air quality of metropolitan independent coffee shops by Random Forests model. Sci Rep 2022; 12:16057. [PMID: 36163251 PMCID: PMC9513105 DOI: 10.1038/s41598-022-20421-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 09/13/2022] [Indexed: 11/30/2022] Open
Abstract
Independent coffee shops are the alternative workplaces for people working remotely from traditional offices but are not concerned about their indoor air quality (IAQ). This study aimed to rank the environmental factors in affecting the IAQ by Random Forests (RFs) models. The indoor environments and human activities of participated independent coffee shops were observed and recorded for 3 consecutive days including weekdays and weekend during the business hours. The multi-sized particulate matter (PM), particle-bound polycyclic aromatic hydrocarbons (p-PAHs), total volatile organic compounds (TVOCs), CO, CO2, temperature and relative humidity were monitored. RFs models ranked the environmental factors. More than 20% of the 15-min average concentrations of PM10, PM2.5, and CO2 exceeded the World Health Organization guidelines. Occupant density affected TVOCs, p-PAHs and CO2 concentrations directly. Tobacco smoking dominated PM10, PM2.5, TVOCs and p-PAHs concentrations mostly. CO concentration was affected by roasting bean first and tobacco smoking secondly. The non-linear relationships between temperature and these pollutants illustrated the relative low concentrations happened at temperature between 22 and 24 °C. Tobacco smoking, roasting beans and occupant density are the observable activities to alert the IAQ change. Decreasing CO2 and optimizing the room temperature could also be the surrogate parameters to assure the IAQ.
Collapse
|
2
|
Xiao L, Du Z. Effects of Evaporative Cooling Air Conditioning on Classroom Pollutants and Thermal Environment. ENVIRONMENTAL HEALTH INSIGHTS 2022; 16:11786302221113995. [PMID: 35899225 PMCID: PMC9310290 DOI: 10.1177/11786302221113995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 06/29/2022] [Indexed: 06/15/2023]
Abstract
Indoor particles and carbon dioxide concentration are major indices to evaluate indoor air quality. Based on the two-dimensional filler sieving model of the direct evaporative cooling segment, the porous media model was used for the simulation of the water filler section, the filtering efficiency of particle was simulated by adjusting the water drenching density and airflow velocity in different operating conditions. The three-dimensional classroom model used to change the exhaust outlet position and control the use of air conditioners simulated the indoor thermal environment and the changes in pollutant concentration. The Euler method and Lagrangian method were used to analyze the indoor flow field and particle sieving in the direct evaporation section, respectively. Conclusions show that in the application of evaporative cooling and stratum ventilation air conditioning system in classroom, the position of the exhaust port affects the concentration of carbon dioxide in the student's breathing area. The water filler section can effectively reduce the concentration of particle and carbon dioxide supplied indoors. The filtration efficiency of particle in outdoor air passing through the direct evaporative cooling section based on diffusion, inertial collision, and interception is affected by the combined effect of particle size, onward wind speed, and water spray density. The filtration efficiency of particle increases as the density of the spray water increases. With the increase of head-on wind speed, the filtration efficiency of coarse particulate matter is higher than that of fine particulate matter. The research results help policy makers decide whether to install evaporative cooling air conditioning in schools and determine which exhaust outlet positions are most effective in improving indoor air quality.
Collapse
Affiliation(s)
| | - Zhenyu Du
- Zhenyu Du, College of Civil Engineering, Taiyuan University of Technology, No. 79 West Street Yingze, Taiyuan, Shanxi 030024, China.
| |
Collapse
|
3
|
An Assessment of Airborne Bacteria and Fungi in the Female Dormitory Environment: Level, Impact Factors and Dose Rate. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19116642. [PMID: 35682227 PMCID: PMC9180550 DOI: 10.3390/ijerph19116642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/18/2022] [Accepted: 05/27/2022] [Indexed: 11/17/2022]
Abstract
In this study, the levels of airborne bacteria and fungi were tested in a female dormitory room; the effects of heating, relative humidity and number of occupants on indoor microorganisms were analyzed and the dose rate of exposure to microbes was assessed. The bacterial and fungal concentrations in the room ranged from 100 to several thousand CFU/m3, and the highest counts were observed in the morning (930 ± 1681 CFU/m3). Staphylococcus spp. and Micrococcus spp. were found in the dormitory. When the heating was on, the total bacterial and fungal counts were lower than when there was no heating. Moreover, statistically significant differences were observed for bacterial concentrations during the morning periods between the times when there was no heating and the times when there was heating. The number of occupants had an obvious positive effect on the total bacterial counts. Moreover, RH had no correlation with the airborne fungi in the dormitory, statistically. Furthermore, the highest dose rate from exposure to bacteria and fungi was observed during sleeping hours. The dose rate from exposure to airborne microorganisms in the dormitory was associated with the activity level in the room. These results helped to elucidate the threat of bioaerosols to the health of female occupants and provide guidance for protective measures.
Collapse
|
4
|
Amouei Torkmahalleh M, Turganova K, Zhigulina Z, Madiyarova T, Adotey EK, Malekipirbazari M, Buonanno G, Stabile L. Formation of cluster mode particles (1-3 nm) in preschools. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 818:151756. [PMID: 34822884 DOI: 10.1016/j.scitotenv.2021.151756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 11/11/2021] [Accepted: 11/13/2021] [Indexed: 06/13/2023]
Abstract
This study is the first study that reports the cluster particle (1-3 nm) formation (CPF) in two modern preschools located in Nur-Sultan city of Kazakhstan from October 28 to November 27, 2019. The average particle number concentration and mode diameter values during major CPF events in Preschool I and Preschool II were found to be 1.90 × 106 (SD 6.43 × 106) particles/cm3 and 1.60 (SD 0.85) nm, and 1.11 × 109 (SD 5.46 × 109) particles/cm3 and 2.16 (SD 1.47) nm, respectively. The ultraviolet PM concentration reached as high as 7 μg/m3 in one of the measurement days. The estimated emission rate in Preschool I for CPF events was 9.57 × 109 (SD 1.92 × 109) particles/min. For Preschool II, the emission rate was 7.25 × 109 (SD 12.4 × 109) particles/min. We identified primary cluster particles (CPs) emitted directly from the sources such as candle burning, and secondary CPs formed as a result of the oxidation of indoor VOCs or smoking VOCs. The secondary CPs are likely to be SOA. Indoor VOCs were mainly emitted during cleaning activities as well as during painting and gluing. Indoor VOCs are the controlling factors in the CPF events. Changes in the training and cleaning programs may result in significant reductions in the exposure of the children to CPs.
Collapse
Affiliation(s)
- Mehdi Amouei Torkmahalleh
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan.
| | - Kamila Turganova
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Zhuldyz Zhigulina
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Tomiris Madiyarova
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Enoch Kwasi Adotey
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Milad Malekipirbazari
- Department of Industrial Engineering, Bilkent University, 06800 Bilkent, Ankara, Turkey
| | - Giorgio Buonanno
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, via Di Biasio 43, Cassino 03043, Italy
| | - Luca Stabile
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, via Di Biasio 43, Cassino 03043, Italy
| |
Collapse
|
5
|
Amouei Torkmahalleh M, Zhigulina Z, Madiyarova T, Turganova K, Adotey EK, Sabanov S. Exposure to fine, ultrafine particles and black carbon in two preschools in nur-sultan city of kazakhstan. INDOOR AIR 2021; 31:1178-1186. [PMID: 33506564 DOI: 10.1111/ina.12799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 01/09/2021] [Indexed: 06/12/2023]
Abstract
Children in preschools were studied as an exceptionally vulnerable group to lung diseases due to their immature immune system. Few data are available in the literature addressing the exposure of children in preschools to ultrafine (>10 nm) particles. Exposure of children to fine, ultrafine (10 nm-1 µm) particles and black carbon particles present inside and near two preschools in Nur-Sultan, Kazakhstan, during Fall 2019 was investigated. For Preschool I, the average daily (6 h) indoor (outdoor) PM1 , PM2.5 , and PM10 concentrations over three-week measurements were 15.0 (SD 12.5) µg/m3 , 34.6 (SD 35.1) µg/m3 , and 47.2 (SD 45.2) µg/m3 , respectively. Average indoor UFP concentrations (>10.0 nm) including candle burning events were 5.20 × 103 (SD 8.80 × 103 ) particles/cm3 , with the background UFP concentration to be 3.30 × 103 (SD 1.80 × 103 ) particles/cm3 . In Preschool II, the average UFP concentration (>30.0 nm) in the morning and afternoon was 3.94 × 103 (SD 5.34 × 102 ) and 3.36 × 103 (SD 1.90 × 103 ) particles/cm3 , respectively. Indoor black carbon (BC) concentrations were correlated with the outdoor smoking activity. The major sources of the indoor particles in the preschools were dust resuspension, candle burning, and infiltrated outdoor particles.
Collapse
Affiliation(s)
- Mehdi Amouei Torkmahalleh
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Zhuldyz Zhigulina
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Tomiris Madiyarova
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Kamila Turganova
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Enoch K Adotey
- Department of Chemical and Materials Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Sergei Sabanov
- Department of Mining, School of Mining and Geosciences, Nur-Sultan, Kazakhstan
| |
Collapse
|
6
|
Li H, Li X, Zheng H, Liu L, Wu Y, Zhou Y, Meng X, Hong J, Cao L, Lu Y, Dong X, Xia M, Ding B, Qian L, Wang L, Zhou W, Gui Y, Kan H, Chen R, Zhang X. Ultrafine particulate air pollution and pediatric emergency-department visits for main respiratory diseases in Shanghai, China. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 775:145777. [PMID: 33631593 DOI: 10.1016/j.scitotenv.2021.145777] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 01/31/2021] [Accepted: 02/06/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND Few studies have explored the short-term effects of ultrafine particles (UFPs, particles < 0.1 μm) air pollution on the exacerbations of pediatric respiratory diseases. OBJECTIVES We aimed to evaluate short-term association between UFP and emergency-department visits (EDVs) for main pediatric respiratory diseases. METHODS We collected daily data on UFP and pediatric EDVs for main respiratory diseases [asthma, pneumonia, bronchitis and upper respiratory tract infections (URTI)] from 66 hospitals in Shanghai, China from 2016 to 2018. Generalized additive models combined with polynomial distributed lag models were applied to explore the associations between UFP level and pediatric EDVs for respiratory diseases. We fitted two-pollutant models with criteria air pollutants and performed stratified analyses by gender and age. RESULTS UFP was associated with increased EDVs for all respiratory diseases in cumulative lags up to 2 d and 3 d. The greatest risk was found at cumulative lags (0-2 d) for all respiratory diseases. At cumulative lags (0-2 d), an interquartile range increase in concentrations of UFP (1800 particles/cm3) was associated with relative risks of EDVs due to asthma [1.35, 95% confidence interval (CI): 1.14-1.59], pneumonia (1.20, 95% CI: 1.04-1.38), bronchitis (1.17, 95% CI: 1.03-1.33) and URTI (1.14, 95% CI: 1.02-1.28). These associations were almost unchanged when controlling for criteria air pollutants, and there was no threshold below which the associations were not present. There were stronger associations in children aged 0-13 years. CONCLUSIONS Short-term exposure to UFP may independently increase the risks of EDVs for asthma, pneumonia, bronchitis and URTI exacerbations among children.
Collapse
Affiliation(s)
- Hongjin Li
- School of Public Health, Key Lab of Public Health Safety of the Ministry of Education and NHC Key Laboratory of Health Technology Assessment, Fudan University, Shanghai 200032, China
| | - Xiaoling Li
- Department of Respiratory Medicine, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Hongmei Zheng
- Department of Respiratory Medicine, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Lijuan Liu
- Department of Respiratory Medicine, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Yihan Wu
- School of Public Health, Key Lab of Public Health Safety of the Ministry of Education and NHC Key Laboratory of Health Technology Assessment, Fudan University, Shanghai 200032, China
| | - Yufeng Zhou
- Institute of Pediatrics, Children's Hospital of Fudan University, Shanghai 201102, China; Institutes of Biomedical Sciences, Fudan University, Shanghai 200032, China
| | - Xia Meng
- School of Public Health, Key Lab of Public Health Safety of the Ministry of Education and NHC Key Laboratory of Health Technology Assessment, Fudan University, Shanghai 200032, China
| | - Jianguo Hong
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai 200080, China
| | - Lanfang Cao
- Department of Pediatrics, Renji Hospital, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Yanming Lu
- Department of Pediatrics, South Campus, Renji Hospital, Shanghai Jiao Tong University, Shanghai 201112, China
| | - Xiaoyan Dong
- Department of Respiratory Medicine, Children's Hospital of Shanghai Jiaotong University, Shanghai 200040, China
| | - Min Xia
- Department of Pediatrics, Renji Hospital, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Bo Ding
- Department of Pediatrics, South Campus, Renji Hospital, Shanghai Jiao Tong University, Shanghai 201112, China
| | - Liling Qian
- Department of Respiratory Medicine, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Libo Wang
- Department of Respiratory Medicine, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Wenhao Zhou
- Department of Neonatology, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Yonghao Gui
- Cardiovascular Center, Children's Hospital of Fudan University, Shanghai 201102, China
| | - Haidong Kan
- School of Public Health, Key Lab of Public Health Safety of the Ministry of Education and NHC Key Laboratory of Health Technology Assessment, Fudan University, Shanghai 200032, China
| | - Renjie Chen
- School of Public Health, Key Lab of Public Health Safety of the Ministry of Education and NHC Key Laboratory of Health Technology Assessment, Fudan University, Shanghai 200032, China.
| | - Xiaobo Zhang
- Department of Respiratory Medicine, Children's Hospital of Fudan University, Shanghai 201102, China.
| |
Collapse
|
7
|
Madureira J, Slezakova K, Silva AI, Lage B, Mendes A, Aguiar L, Pereira MC, Teixeira JP, Costa C. Assessment of indoor air exposure at residential homes: Inhalation dose and lung deposition of PM 10, PM 2.5 and ultrafine particles among newborn children and their mothers. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 717:137293. [PMID: 32092813 DOI: 10.1016/j.scitotenv.2020.137293] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 01/28/2020] [Accepted: 02/11/2020] [Indexed: 06/10/2023]
Abstract
Accurate assessment of particulate matter (PM) dose and respiratory deposition is essential to better understand the risks of exposure to PM and, consequently, to develop the respective risk-control strategies. In homes, this is especially relevant in regards to ultrafine particles (UFP; <0.1 μm) which origin in these environments is mostly due to indoor sources. Thus, this study aimed to estimate inhalation doses for different PM mass/number size fractions (i.e., PM10, PM2.5 and UFP) in indoor air of residential homes and to quantify the deposition (total, regional and lobar) in human respiratory tract for both newborn children and mothers. Indoor real-time measurements of PM10, PM2.5 and UFP were conducted in 65 residential homes situated in Oporto metropolitan area (Portugal). Inhalation doses were estimated based on the physical characteristics of individual subjects and their activity patterns. The multi-path particle dosimetry model was used to quantify age-specific depositions in human respiratory tract. The results showed that 3-month old infants exhibited 4-fold higher inhalation doses than their mothers. PM10 were primarily deposited in the head region (87%), while PM2.5 and UFP depositions mainly occurred in the pulmonary area (39% and 43%, respectively). Subject age affected the pulmonary region and the total lung deposition; higher deposition being observed among the newborns. Similarly, lower lobes (left lobe: 37% and right lobe: 30%) received higher PM deposition than upper and middle lobes; right lobes lung are prone to be more susceptible to respiratory problems, since asymmetric deposition was observed. Considering that PM-related diseases occur at specific sites of respiratory system, quantification of site-specific particle deposition should be predicted in order to better evidence the respective health outcomes resulting from inhaled PM.
Collapse
Affiliation(s)
- Joana Madureira
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal.
| | - Klara Slezakova
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| | - Ana Inês Silva
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal; ICBAS-Institute of Biomedical Sciences Abel Salazar, U. Porto-University of Porto, Rua de Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal
| | - Bruna Lage
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| | - Ana Mendes
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| | - Lívia Aguiar
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal
| | - Maria Carmo Pereira
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - João Paulo Teixeira
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| | - Carla Costa
- Environmental Health Department, National Institute of Health, Rua Alexandre Herculano, 321, 4000-055 Porto, Portugal; EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| |
Collapse
|
8
|
Prokopciuk N, Franck U, Dudoitis V, Tarasiuk N, Juskiene I, Valiulis A, Cepuraite D, Staras K, Ulevicius V. On the seasonal aerosol pollution levels and its sources in some primary schools in Vilnius, Lithuania. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:15592-15606. [PMID: 32080817 DOI: 10.1007/s11356-020-08093-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 02/12/2020] [Indexed: 06/10/2023]
Abstract
Aerosol particle number (PNC) and mass concentrations (PMC) were studied in 11 primary schools during the 2017-2018 school years (from September to May) in Vilnius, Lithuania, with the aim to evaluate the main aerosol pollution sources and its levels. Expeditious information on the total aerosol particle concentration over the full range of sizes (from 0.01 to > 1 μm) was estimated using a condensation particle counter (CPC). Particle number and mass concentrations in the size range of 0.3-10 μm were measured and estimated using an optical particle sizer (OPS). The use of aerosol particle size spectra (OPS) in school lodgements facilitated the identification of the main sources of indoor air pollution. The main sources responsible for the elevated levels of indoor PN and PM aerosol concentrations were determined: local canteens in the absence of ventilation (particle concentrations up to 97,500 part/cm3 (CPC)), the school-grader activity during the lesson breaks (275-586 μg/m3), soft furniture and carpets in the classrooms and corridors (~ 200 μg/m3), and in some cases (city center) elevated outdoor aerosol pollution levels (16800-18,170 part/cm3). Elevated aerosol pollution levels were also due to the occasional sources: construction works during lessons (200-1000 μg/m3), scraping the exterior walls of buildings near schools (up to 1600 μg/m3), and the use of petrol-powered trimmers during cutting of green plantings (22500-66,400 part/cm3 (CPC)).
Collapse
Affiliation(s)
- Nina Prokopciuk
- SRI Center for Physical Sciences and Technology, Savanorių ave. 231, 02300, Vilnius, Lithuania.
| | - Ulrich Franck
- Helmholtz Centre for Environmental Research-UFZ, Permoserstrasse 15, 04318, Leipzig, Germany
| | - Vadimas Dudoitis
- SRI Center for Physical Sciences and Technology, Savanorių ave. 231, 02300, Vilnius, Lithuania
| | - Nikolaj Tarasiuk
- SRI Center for Physical Sciences and Technology, Savanorių ave. 231, 02300, Vilnius, Lithuania
| | - Izabele Juskiene
- Vilnius University Faculty of Medicine, Institute of Clinical Medicine, M.K. Ciurlionio St. 21, /27, Vilnius, Lithuania
| | - Arunas Valiulis
- Vilnius University Faculty of Medicine, Institute of Clinical Medicine, M.K. Ciurlionio St. 21, /27, Vilnius, Lithuania
| | - Daiva Cepuraite
- Vilnius University Faculty of Medicine, Public Institution Vilnius Centro Outpatient Clinic, Pylimo St. 3, 01117, Vilnius, Lithuania
| | - Kestutis Staras
- Vilnius University Faculty of Medicine, Public Institution Vilnius Centro Outpatient Clinic, Pylimo St. 3, 01117, Vilnius, Lithuania
| | - Vidmantas Ulevicius
- SRI Center for Physical Sciences and Technology, Savanorių ave. 231, 02300, Vilnius, Lithuania
| |
Collapse
|
9
|
Slezakova K, Pereira MC, Morais S. Ultrafine particles: Levels in ambient air during outdoor sport activities. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 258:113648. [PMID: 31806467 DOI: 10.1016/j.envpol.2019.113648] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Revised: 10/28/2019] [Accepted: 11/18/2019] [Indexed: 05/06/2023]
Abstract
Conducting aerobic activity on regular basis is recognised as one of the steps to maintain healthier lifestyle. The positive outcomes though can be outweighed if conducted in polluted atmosphere. Furthermore, the specific inhalation during exercising, which results in bypass of nasal filtration systems and deeper penetration into the respiratory system, might result in higher risks especially to pollutants such as ultrafine particles (UFP), which aerodynamic particle diameter are <100 nm. Thus, this work aims to evaluate UFP levels at sites used for conducting physical sport activities outdoors and to estimate the respective inhalation doses considering various scenarios and different physical activities. Monitoring of UFP was conducted during three weeks (May-June 2015) at four different sites (S1-S4) regularly used to conduct physical exercising. The results showed that UFP highly varied (medians 5.1-20.0 × 103 # cm-3) across the four sites, with the highest UFP obtained when exercising next to trafficked streets whereas S3 and S4 (a garden and city park) exhibited 2-4 times lower UFP. In view of the obtained UFP concentrations, the estimated inhalation doses ranged 1.73 × 108-3.81 × 108 # kg-1 when conducting moderately intense sport activities and 1.93 × 108-5.95 × 108 # kg-1 for highly intense ones. Highly intense activities (i.e. running) led to twice higher UFP exposure; children and youths (5-17 yrs old) experienced 203-267% higher doses. Considering the age- and gender- differences, estimated UFP doses of males were 1.1-2.8 times higher than of females. Finally, UFP inhalation doses estimated for walking (commuting to work and/or schools) were 1.6-7.5 times lower than when conducting sport activities. Thus to protect public health and to promote healthy and physically active lifestyle, strategies to minimize the negative impacts of air pollution should be developed and implemented.
Collapse
Affiliation(s)
- Klara Slezakova
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Maria Carmo Pereira
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal.
| |
Collapse
|
10
|
Felgueiras F, Mourão Z, Morais C, Santos H, Gabriel MF, de Oliveira Fernandes E. Comprehensive assessment of the indoor air quality in a chlorinated Olympic-size swimming pool. ENVIRONMENT INTERNATIONAL 2020; 136:105401. [PMID: 31884411 DOI: 10.1016/j.envint.2019.105401] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 12/03/2019] [Accepted: 12/07/2019] [Indexed: 06/10/2023]
Abstract
Elite swimmers and swimming pool employees are likely to be at greater health risk due to their regular and intense exposure to air stressors in the indoor swimming pool environment. Since data on the real long-term exposure is limited, a long-term monitoring and sampling plan (22 non-consecutive days, from March to July 2017) was carried out in an indoor Olympic-size pool with a chlorine-based disinfection method to characterize indoor environments to which people involved in elite swimming and maintenance staff may be exposed to. A comprehensive set of parameters related with comfort and environmental conditions (temperature, relative humidity (RH), carbon dioxide (CO2) and monoxide and ultrafine particles (UFP)) were monitored both indoors and outdoors in order to determine indoor-to-outdoor (I/O) ratios. Additionally, an analysis of volatile organic compounds (VOC) concentration and its dynamics was implemented in three 1-hr periods: early morning, evening elite swimmers training session and late evening. Samplings were simultaneously carried out in the air layer above the water surface and in the air surrounding the pool, selected to be representative of swimmers and coaches/employees' breathing zones, respectively. The results of this work showed that the indoor climate was very stable in terms of air temperature, RH and CO2. In terms of the other measured parameters, mean indoor UFP number concentrations (5158 pt/cm3) were about 50% of those measured outdoors whereas chloroform was the predominant substance detected in all samples collected indoors (13.0-369.3 µg/m3), among a varied list of chemical compounds. An I/O non-trihalomethanes (THM) VOC concentration ratio of 2.7 was also found, suggesting that, beyond THM, other potentially hazardous VOC have also their source(s) indoors. THM and non-THM VOC concentration were found to increase consistently during the evening training session and exhibited a significant seasonal pattern. Compared to their coaches, elite swimmers seemed to be exposed via inhalation to significantly higher total THM levels, but to similar concentrations of non-THM VOC, during routine training activities. Regarding swimming employees, the exposure to THM and other VOC appeared to be significantly minimized during the early morning period. The air/water temperature ratio and RH were identified as important parameters that are likely to trigger the transfer processes of volatile substances from water to air and of their accumulation in the indoor environment of the swimming pool, respectively.
Collapse
Affiliation(s)
- Fátima Felgueiras
- INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal
| | - Zenaida Mourão
- INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal
| | - Catarina Morais
- INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal
| | - Hugo Santos
- INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal
| | - Marta Fonseca Gabriel
- INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal.
| | | |
Collapse
|
11
|
García-Hernández C, Ferrero A, Estarlich M, Ballester F. Exposure to ultrafine particles in children until 18 years of age: A systematic review. INDOOR AIR 2020; 30:7-23. [PMID: 31692140 DOI: 10.1111/ina.12620] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 09/11/2019] [Accepted: 10/10/2019] [Indexed: 06/10/2023]
Abstract
Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. The bibliographical search was carried out in July 2019 using the online database PubMed and was completed with references in articles found in the search. We selected the studies that used continuous counters and measured UFP levels in both specific microenvironment (houses, schools, transport, etc) and personal exposure. Finally, 32 studies fulfilled the criteria: of these, 10 analyzed personal exposure and 22 examined UFP levels in the microenvironment (especially in schools or nurseries (18/22)) and five in various microenvironments (including dwellings and means of transport, where exposure levels were higher). The characteristics of the microenvironments with the greatest levels of UFP were being close to heavy traffic or near cooking and cleaning activities. This review revealed the wide differences in exposure assessment methodologies that could lead to a lack of uniform and comparable information about the real UFP exposure in children.
Collapse
Affiliation(s)
- Celia García-Hernández
- FISABIO-Universitat Jaume I-Universitat de València Joint Research Unit of Epidemiology and Environmental Health, Valencia, Spain
| | - Amparo Ferrero
- FISABIO-Universitat Jaume I-Universitat de València Joint Research Unit of Epidemiology and Environmental Health, Valencia, Spain
- Spanish Consortium for Research on Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - Marisa Estarlich
- FISABIO-Universitat Jaume I-Universitat de València Joint Research Unit of Epidemiology and Environmental Health, Valencia, Spain
- Spanish Consortium for Research on Epidemiology and Public Health (CIBERESP), Madrid, Spain
- Nursing School, Universitat de València, Valencia, Spain
| | - Ferran Ballester
- FISABIO-Universitat Jaume I-Universitat de València Joint Research Unit of Epidemiology and Environmental Health, Valencia, Spain
- Spanish Consortium for Research on Epidemiology and Public Health (CIBERESP), Madrid, Spain
- Nursing School, Universitat de València, Valencia, Spain
| |
Collapse
|
12
|
Li Y, Ge Y, Wu C, Guan D, Liu J, Wang F. Assessment of culturable airborne bacteria of indoor environments in classrooms, dormitories and dining hall at university: a case study in China. AEROBIOLOGIA 2020; 36:313-324. [PMID: 32421086 PMCID: PMC7223800 DOI: 10.1007/s10453-020-09633-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 02/21/2020] [Indexed: 05/05/2023]
Abstract
University students' health may be adversely affected by exposure to indoor bacterial contaminants on their campuses. This study aims (1) to quantify culturable bacterial concentrations in three indoor environments at a university, (2) to investigate the influence of meteorological factors and gender, to assess the relationship between indoor and outdoor, and (3) to estimate the bacterial dose for university students in different indoor environments. Airborne bacteria samples were collected in 12 classrooms, in 12 living rooms and four bathrooms in two dormitory buildings, and in a dining hall. The results showed that the microenvironment in the female dormitory had the highest mean bacterial concentration (2847 CFU/m3), whereas the lowest mean bacterial concentration was observed in classrooms (162 CFU/m3). Indoor bacterial concentrations in male dormitories were significantly lower than in female dormitories probably because of crowding and increased ventilation. Outdoor weather conditions were associated with the indoor concentrations with regard to insufficient ventilation and varying outdoor concentration. The occupants' activity level was also more closely related to the indoor bacteria concentration in the residential setting. Students experienced about four times higher dose of airborne bacteria in the dormitories than in the classrooms and dining hall.
Collapse
Affiliation(s)
- Yanju Li
- School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China
| | - Yanhui Ge
- School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin, China
| | - Chunbin Wu
- School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China
| | - Dexing Guan
- School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China
| | - Jinbao Liu
- School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin, China
| | - Fuyang Wang
- School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin, China
| |
Collapse
|
13
|
Slezakova K, de Oliveira Fernandes E, Pereira MDC. Assessment of ultrafine particles in primary schools: Emphasis on different indoor microenvironments. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 246:885-895. [PMID: 31159138 DOI: 10.1016/j.envpol.2018.12.073] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Revised: 12/21/2018] [Accepted: 12/22/2018] [Indexed: 05/07/2023]
Abstract
Due to the negative health impacts, significant efforts have been directed towards investigating ultrafine particle (UFP) exposure in various indoor environments. As children spend approximately one third of their time in schools, educatory environments deserve particular attention; however, majority of past research has focused on UFP assessment in classrooms. Thus, this work aims to expand the characterization of UFP in primary schools by considering different indoor and outdoor school microenvironments and estimating inhalation doses for the respective students (6-11yrs old). Real-time UFP measurements were daily conducted (9:00-17:30) in 20 primary schools in Oporto (January-April 2014; October-February 2015) in classrooms, canteens, gyms, libraries, and concurrently outdoors. Overall, UFP concentrations showed large temporal and spatial variations. For classrooms (n = 73), median UFP (1.56 × 103-16.8 × 103 # cm-3) were lower than the corresponding levels in ambient air of schools (1.79 × 103-24.1 × 103 # cm-3). Outdoor emissions contributed to indoor UFP (indoor-to-outdoor ratios I/O of 0.0.30-0.85), but ventilation, room characteristics and its occupancy were identified as important parameters contributing to overall indoor UFP levels. Considering specific indoor school microenvironments, canteens were the microenvironment with the highest UFP levels (5.47 × 103-36.4 × 103 # cm-3), cooking conducted directly on school grounds resulted in significantly elevated UFP in the respective classrooms (p < 0.05); the lowest UFP were found in libraries (4.45 × 103-8.50 × 103 # cm-3) mostly due to the limited occupancies. Although students spend majority of their school time in classrooms (66-71%), classroom exposure was not consistently the predominant contributor to school total UFP inhalation dose (29-75%). Outdoor exposure contributed 23-70% of school dose (depending on UFP levels in ambient levels and/or conducted activities) whereas short periods of lunch break accounted for 8-40%. Therefore, when evaluating UFP exposure in educatory settings other microenvironments beyond classrooms should be an integral part of the study.
Collapse
Affiliation(s)
- Klara Slezakova
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465, Porto, Portugal
| | | | - Maria do Carmo Pereira
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465, Porto, Portugal.
| |
Collapse
|
14
|
Slezakova K, Peixoto C, Carmo Pereira MD, Morais S. (Ultra) Fine particle concentrations and exposure in different indoor and outdoor microenvironments during physical exercising. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2019; 82:591-602. [PMID: 31288676 DOI: 10.1080/15287394.2019.1636494] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Although regular exercise improves overall well-being, increased physical activity results in enhanced breathing which consequently leads to elevated exposure to a variety of air pollutants producing adverse effects. It is well-known that one of these ambient air contaminants is ultrafine particles (UFP). Thus, this study aimed to (1) examine exposure to particle number concentrations (PNC) in size ranging from N20-1000 nm in different sport environments and (2) estimate the respective inhalation doses across varying activity scenarios based upon the World Health Organization recommendations for physical activity. PNC were continuously monitored (TSI P-Trak™ condensation particle counter) outdoors (Out1-Out2) and indoors (Ind1-Ind2; fitness clubs) over 4 weeks. Outdoor PNC (total median 12 563 # cm-3; means of 20 367 # cm-3 at Out1 and 7 122 # cm-3 at Out2) were approximately 1.6-fold higher than indoors (total median 7 653 # cm-3; means of 11 861 # cm-3 at Ind1 and 14 200 # cm-3 at Ind2). The lowest doses were inhaled during holistic group classes (7.91 × 107-1.87 × 108 # per kg body weight) whereas exercising with mixed cardio and strength training led to approximately 1.8-fold higher levels. In order to optimize the health benefit of exercises, environmental characteristics of the locations at which physical activities are conducted need to be considered.
Collapse
Affiliation(s)
- Klara Slezakova
- a LEPABE, Faculdade de Engenharia, Universidade do Porto , Porto , Portugal
- b REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
| | - Cátia Peixoto
- b REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
| | | | - Simone Morais
- b REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
| |
Collapse
|
15
|
Hwang SH, Park WM. Radon and PM 10 concentrations in underground parking lots and subway stations with health risks in South Korea. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:35242-35248. [PMID: 30341751 DOI: 10.1007/s11356-018-3428-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Accepted: 10/08/2018] [Indexed: 06/08/2023]
Abstract
This study examined the environmental factors that affect indoor radon (Rn) and particulate matter (PM10) concentrations in underground public facilities such as subway stations and underground parking lots. Rn and PM10 concentrations from March 2014 to October 2015 were evaluated at 40 subway stations and 19 underground parking lots. Average underground concentrations of Rn and PM10 were 37.3 ± 17.1 Bq/m3 and 78.6 ± 15.1 μg/m3, respectively. There were significant difference in Rn concentration between sampling points, with the highest concentration 41.8 ± 18.1 Bq/m3 on subway platforms, while the highest concentration of PM10 was 83.7 ± 13.8 μg/m3 in transfer pathways. Rn concentration showed positive correlation with PM10 concentration (r = 0.380, p < 0.001). The highest Rn concentration occurred during fall season, followed by summer and spring. At 60-h exposure duration in underground subway stations and parking lots, the hazard quotient (HQ) of Rn exceeded 1 for children less than 1 year old and those between 8 and 10 years old.
Collapse
Affiliation(s)
- Sung Ho Hwang
- National Cancer Center, National Cancer Control Institute, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, South Korea
| | - Wha Me Park
- The Institute for Occupational Health, Yonsei University College of Medicine, Seoul, South Korea.
- Graduate School of Public Health, Yonsei University, Seoul, South Korea.
| |
Collapse
|
16
|
Hwang SH, Roh J, Park WM. Evaluation of PM 10, CO 2, airborne bacteria, TVOCs, and formaldehyde in facilities for susceptible populations in South Korea. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 242:700-708. [PMID: 30029169 DOI: 10.1016/j.envpol.2018.07.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Revised: 06/27/2018] [Accepted: 07/04/2018] [Indexed: 06/08/2023]
Abstract
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations; however, few studies have measured multiple pollutants in facilities for susceptible populations at a national scale in South Korea. Therefore, we measured the concentrations of indoor pollutants (fine particulate matter (PM10), CO2, airborne bacteria (AB), total volatile organic compounds (TVOCs), and formaldehyde) to determine their possible relation to other indoor environmental factors and characteristics of facilities with susceptible populations, such as hospitals, geriatric hospitals, elderly care facilities, and postnatal care centers throughout South Korea. Indoor pollutants were sampled at 82 indoor facilities, including 62 facilities for susceptible populations. Spearman's correlation, Kruskal-Wallis, and Mann-Whitney analyses were used to examine the relationship among and differences between pollutants at indoor facilities and indoor/outdoor differences in PM10 concentration. There were significant correlations between indoor temperature and AB concentration (r = 0.37, p < 0.01), TVOCs, and formaldehyde (r = 0.264, p < 0.01). Indoor PM10 concentrations were higher than outdoor concentrations at all facilities for susceptible populations (p < 0.01). CO2 might be a good indicator for predicting indoor pollutants when categorized into two levels (≤750 ppm and >750 ppm). The hazard quotient of formaldehyde was higher than the acceptable level of 1 for children under the age of eight in postnatal care centers, indicative of unsafe levels. Therefore, more depth study for exposure characteristics of formaldehyde and indoor air quality (IAQ) in postnatal care facilities as a national scale is needed for finding the children exposure levels.
Collapse
Affiliation(s)
- Sung Ho Hwang
- National Cancer Control Institute, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si Gyeonggi-do, South Korea
| | - Jaehoon Roh
- The Institute for Occupational Health, Yonsei University College of Medicine, South Korea; Graduate School of Public Health, Yonsei University, South Korea; Department of Preventive Medicine, College of Medicine, Yonsei University, Seoul, South Korea; Inchen Worker's Health Center, Incheon, South Korea
| | - Wha Me Park
- The Institute for Occupational Health, Yonsei University College of Medicine, South Korea; Graduate School of Public Health, Yonsei University, South Korea.
| |
Collapse
|
17
|
Slezakova K, Peixoto C, Pereira MDC, Morais S. Indoor air quality in health clubs: Impact of occupancy and type of performed activities on exposure levels. JOURNAL OF HAZARDOUS MATERIALS 2018; 359:56-66. [PMID: 30014915 DOI: 10.1016/j.jhazmat.2018.07.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 07/02/2018] [Accepted: 07/03/2018] [Indexed: 06/08/2023]
Abstract
Associations between indoor air quality (IAQ) and health in sport practise environments are not well understood due to limited knowledge of magnitude of inhaled pollutants. Thus, this study assessed IAQ in four health clubs (HC1-HC4) and estimated inhaled doses during different types of activities. Gaseous (TVOCs, CO, O3, CO2) and particulate pollutants (PM1, PM4) were continuously collected during 40 days. IAQ was influenced both by human occupancy and the intensity of the performed exercises. Levels of all pollutants were higher when clubs were occupied (p < 0.05) than for vacant periods, with higher medians in main workout areas rather than in spaces/studios for group activities. In all spaces, TVOCs highly exceeded legislative limit (600 μg/m3), even when unoccupied, indicating possible risks for the respective occupants. CO2 levels were well correlated with relative humidity (rs 0.534-0.625) and occupancy due to human exhalation and perspiration during exercising. Clubs with natural ventilations exhibited twice higher PM, with PM1 accounting for 93-96% of PM4; both PM were highly correlated (rs 0.936-0.995) and originated from the same sources. Finally, cardio classes resulted in higher inhalation doses than other types of exercising (1.7-2.6).
Collapse
Affiliation(s)
- Klara Slezakova
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal; LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Cátia Peixoto
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal
| | - Maria do Carmo Pereira
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal.
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal.
| |
Collapse
|
18
|
Hwang SH, Park JB, Lee KJ. Exposure assessment of particulate matter and blood chromium levels in people living near a cement plant. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH 2018; 40:1237-1246. [PMID: 29164359 DOI: 10.1007/s10653-017-0039-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2017] [Accepted: 11/15/2017] [Indexed: 06/07/2023]
Abstract
This study evaluates the effect of air pollution caused by cement plants on nearby residential areas and performs an exposure assessment of particulate matter (PM) and total Cr, Cr6+, Pb, and Al. Further, the blood Cr levels of residents exposed to PM released by cement plants are also assessed. Nine buildings (eight residential and one elementary school building) close to cement plants were selected for this study, which were located in Pyeongtaek port, in west of Gyeonggi Province, South Korea. A total of 51 suspended particulate samples were collected at a flow rate of 2.0 L/min. Total Cr was more widely detected in residents' houses and elementary schools. PM levels were higher at distances of 4.1 and 4.8 km than those at closer distances of 2.7 km. This was due to the influence of wind direction. The estimated mean blood level of Cr for the study participants was 3.80 μg/L, which is higher than levels estimated by other studies on Cr blood levels. Therefore, cement plants could cause an increase in total Cr and blood Cr levels in residential areas, and more continuous monitoring is necessary to better understand their impacts.
Collapse
Affiliation(s)
- Sung Ho Hwang
- National Cancer Control Institute, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, South Korea
| | - Jae Bum Park
- Department of Occupational and Environmental Medicine, School of Medicine, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon, 16499, South Korea
| | - Kyung Jong Lee
- Department of Occupational and Environmental Medicine, School of Medicine, Ajou University, San 5, Woncheon-dong, Yeongtong-gu, Suwon, 16499, South Korea.
| |
Collapse
|
19
|
Slezakova K, Peixoto C, Oliveira M, Delerue-Matos C, Pereira MDC, Morais S. Indoor particulate pollution in fitness centres with emphasis on ultrafine particles. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 233:180-193. [PMID: 29073525 DOI: 10.1016/j.envpol.2017.10.050] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 10/10/2017] [Accepted: 10/12/2017] [Indexed: 06/07/2023]
Abstract
Fitness centres (FC) represent a unique indoor microenvironment. Exercising on regular basis provides countless health benefits and improves overall well-being, but if these facilities have poor indoor air quality, the respective exercisers might be subjected to some adverse risks. Considering the limited existent data, this work aimed to evaluate particulate pollution (PM10, PM2.5, and ultrafine particles - UFP) in indoor air of FC and to estimate the respective risks for occupants (both staff and exercising subjects). Sampling was conducted during 40 consecutive days of May-June 2014 in general fitness areas, studios and classrooms (for group activities) of four different fitness centres (FC1-FC4) situated within Oporto metropolitan area, Portugal. The results showed that across the four FC, PM10 ranged between 5 and 1080 μg m-3 with median concentrations (15-43 μg m-3) fulfilling the limit (50 μg m-3) of Portuguese legislation in all FC. PM2.5 (medians 5-37 μg m-3; range 5-777 μg m-3) exceeded thresholds of 25 μg m-3 at some FC, indicating potential risks for the respective occupants; naturally ventilated FC exhibited significantly higher PM ranges (p < 0.05). Similarly, UFPs (range 0.5-88.6 × 103 # cm-3) median concentrations were higher (2-3 times) at FC without controlled ventilation systems. UFP were approximately twice higher (p < 0.05) during the occupied periods (mean of 9.7 × 103vs. 4.8 × 103 # cm-3) with larger temporal variations of UFP levels observed in general fitness areas than in classrooms and studios. Cardio activities (conducted in studios and classrooms) led to approximately twice the UFPs intakes than other types of exercising. These results indicate that even short-term physical activity (or more specifically its intensity) might strongly influence the daily inhalation dose. Finally, women exhibited 1.2 times higher UFPs intake than men thus suggesting the need for future gender-specific studies assessing UFP exposure.
Collapse
Affiliation(s)
- Klara Slezakova
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal; LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Cátia Peixoto
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal
| | - Marta Oliveira
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal
| | - Cristina Delerue-Matos
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal
| | - Maria do Carmo Pereira
- LEPABE, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal.
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal.
| |
Collapse
|
20
|
Morawska L, Ayoko GA, Bae GN, Buonanno G, Chao CYH, Clifford S, Fu SC, Hänninen O, He C, Isaxon C, Mazaheri M, Salthammer T, Waring MS, Wierzbicka A. Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure. ENVIRONMENT INTERNATIONAL 2017; 108:75-83. [PMID: 28802170 DOI: 10.1016/j.envint.2017.07.025] [Citation(s) in RCA: 135] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 07/27/2017] [Accepted: 07/29/2017] [Indexed: 05/10/2023]
Abstract
It has been shown that the exposure to airborne particulate matter is one of the most significant environmental risks people face. Since indoor environment is where people spend the majority of time, in order to protect against this risk, the origin of the particles needs to be understood: do they come from indoor, outdoor sources or both? Further, this question needs to be answered separately for each of the PM mass/number size fractions, as they originate from different sources. Numerous studies have been conducted for specific indoor environments or under specific setting. Here our aim was to go beyond the specifics of individual studies, and to explore, based on pooled data from the literature, whether there are generalizable trends in routes of exposure at homes, schools and day cares, offices and aged care facilities. To do this, we quantified the overall 24h and occupancy weighted means of PM10, PM2.5 and PN - particle number concentration. Based on this, we developed a summary of the indoor versus outdoor origin of indoor particles and compared the means to the WHO guidelines (for PM10 and PM2.5) and to the typical levels reported for urban environments (PN). We showed that the main origins of particle metrics differ from one type of indoor environment to another. For homes, outdoor air is the main origin of PM10 and PM2.5 but PN originate from indoor sources; for schools and day cares, outdoor air is the source of PN while PM10 and PM2.5 have indoor sources; and for offices, outdoor air is the source of all three particle size fractions. While each individual building is different, leading to differences in exposure and ideally necessitating its own assessment (which is very rarely done), our findings point to the existence of generalizable trends for the main types of indoor environments where people spend time, and therefore to the type of prevention measures which need to be considered in general for these environments.
Collapse
Affiliation(s)
- L Morawska
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Institute of Health and Biomedical Innovation, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia.
| | - G A Ayoko
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Institute of Health and Biomedical Innovation, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia
| | - G N Bae
- Center for Environment, Health and Welfare Research, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - G Buonanno
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Department of Engineering, University of Naples "Parthenope", Isola C4 Centro Direzionale, Naples, Italy; Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, via Di Biasio 43, Cassino (FR), Italy
| | - C Y H Chao
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - S Clifford
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Institute of Health and Biomedical Innovation, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; ARC Centre of Excellence for Mathematical and Statistical Frontiers, Queensland University of Technology, Brisbane 4000, Australia
| | - S C Fu
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - O Hänninen
- National Institute for Health and Welfare, Department of Environmental Health, POB 95/Neulaniementie 4, FI-70701 Kuopio, Finland
| | - C He
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Institute of Health and Biomedical Innovation, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia
| | - C Isaxon
- Division of Ergonomics and Aerosol Technology, Lund University, Box 118, SE-221 00 Lund, Sweden
| | - M Mazaheri
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Institute of Health and Biomedical Innovation, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia
| | - T Salthammer
- International Laboratory for Air Quality and Health, Queensland University of Technology, GPO Box 2434, Brisbane, QLD 4001, Australia; Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany
| | - M S Waring
- Drexel University, Department of Civil, Architectural and Environmental Engineering, 3141 Chestnut St., Philadelphia, PA 19104, USA
| | - A Wierzbicka
- Division of Ergonomics and Aerosol Technology, Lund University, Box 118, SE-221 00 Lund, Sweden
| |
Collapse
|
21
|
Viitanen AK, Uuksulainen S, Koivisto AJ, Hämeri K, Kauppinen T. Workplace Measurements of Ultrafine Particles—A Literature Review. Ann Work Expo Health 2017; 61:749-758. [DOI: 10.1093/annweh/wxx049] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Accepted: 06/08/2017] [Indexed: 01/29/2023] Open
|
22
|
Oliveira M, Slezakova K, Delerue-Matos C, Pereira MDC, Morais S. Indoor air quality in preschools (3- to 5-year-old children) in the Northeast of Portugal during spring-summer season: pollutants and comfort parameters. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2017; 80:740-755. [PMID: 28569620 DOI: 10.1080/15287394.2017.1286932] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Indoor air quality at schools (elementary, primary) has been the subject of many studies; however, there are still relative few data regarding preschool (3- to 5-year-old children) environments. This investigation determined the concentrations of particulate matter (PM)2.5, total volatile organic compounds (TVOC), formaldehyde, carbon monoxide (CO), and ozone (O3) as well as the levels of carbon dioxide (CO2), temperature, and relative humidity (RH) in the indoor and outdoor air of two preschools situated in different geographical regions of Portugal. The indoor concentrations of TVOC, CO, O3, and CO2 were predominantly higher at the end of school day compared to early morning periods. The TVOC and CO2 concentrations were higher indoors than outdoors suggesting predominantly an indoor origin. Outdoor air infiltrations were the major contributing source of CO and O3 to indoor air in both preschools. The concentrations of all pollutants were within the limits defined by national regulations and international organizations, except for TVOC that exceeded 8-12-fold higher than the recommendation of 0.2 mg/m3 proposed by European Commission. The levels of CO2 were below the protective guideline of 2250 mg/m3 (Portuguese legislation); however, the observed ranges exceeded the Portuguese margin of tolerance (2925 mg/m3) at the end of school days, indicating the impact of occupancy rates particularly at one of the preschools. Regarding comfort parameters, temperature exerted a significant influence on O3 concentrations, while RH values were significantly correlated with TVOC levels in indoor air of preschools, particularly during the late afternoon periods.
Collapse
Affiliation(s)
- Marta Oliveira
- a REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
| | - Klara Slezakova
- a REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
- b LEPABE, Departamento de Engenharia Química , Faculdade de Engenharia, Universidade do Porto , Porto , Portugal
| | - Cristina Delerue-Matos
- a REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
| | - Maria do Carmo Pereira
- b LEPABE, Departamento de Engenharia Química , Faculdade de Engenharia, Universidade do Porto , Porto , Portugal
| | - Simone Morais
- a REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto , Porto , Portugal
| |
Collapse
|
23
|
Deng WJ, Zheng HL, Tsui AKY, Chen XW. Measurement and health risk assessment of PM 2.5, flame retardants, carbonyls and black carbon in indoor and outdoor air in kindergartens in Hong Kong. ENVIRONMENT INTERNATIONAL 2016; 96:65-74. [PMID: 27608428 DOI: 10.1016/j.envint.2016.08.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Revised: 07/19/2016] [Accepted: 08/19/2016] [Indexed: 06/06/2023]
Abstract
Indoor air pollution is closely related to children's health. Polybrominated diphenyl ethers (PBDEs) and dechlorane plus (DP) transmitted through indoor PM2.5 and dust, along with carbonyl compounds and black carbon (BC) aerosol were analysed in five Hong Kong kindergartens. The results showed that 60% of the median PM2.5 levels (1.3×101 to 2.9×101μg/m3 for indoor; 9.5 to 8.8×101μg/m3 for outdoor) in the five kindergartens were higher than the guidelines set by the World Health Organization (2.5×101μg/m3). Indoor PM2.5 mass concentrations were correlated with outdoor PM2.5 in four of the kindergartens. The PBDEs (0.10-0.64ng/m3 in PM2.5; 0.30-2.0×102ng/g in dust) and DP (0.05-0.10ng/m3 in PM2.5; 1.3-8.7ng/g in dust) were detected in 100% of the PM2.5 and dust samples. Fire retardant levels in the air were not correlated with the levels of dust in this study. The median BC concentrations varied by >7-fold from 8.8×102ng/m-3 to 6.7×103ng/m-3 and cooking events might have caused BC concentrations to rise both indoors and outdoors. The total concentrations of 16 carbonyls ranged from 4.7×101μg/m3 to 9.3×101μg/m3 indoors and from 1.9×101μg/m3 to 4.3×101μg/m3 outdoors, whilst formaldehyde was the most abundant air carbonyl. Indoor carbonyl concentrations were correlated with outdoor carbonyls in three kindergartens. The health risk assessment showed that hazard indexes (HIs) HIs of non-cancer risks from PBDEs and DPs were all lower than 0.08, whilst non-cancer HIs of carbonyl compounds ranged from 0.77 to 1.85 indoors and from 0.50 to 0.97 outdoors. The human intake of PBDEs and DP through inhalation of PM2.5 accounted for 78% to 92% of the total intake. The cancer hazard quotients (HQs) of formaldehyde ranged from 4.5E-05 to 2.1E-04 indoors and from 1.9E-05 to 6.2E-05 outdoors. In general, the indoor air pollution in the five Hong Kong kindergartens might present adverse effects to children, although different schools showed distinct pollution levels, so indoor air quality might be improved through artificial measures. The data will be useful to developing a feasible management protocol for indoor environments.
Collapse
Affiliation(s)
- Wen-Jing Deng
- Department of Science and Environmental Studies, The Education University of Hong Kong, Tai Po, N.T., Hong Kong, China.
| | - Hai-Long Zheng
- Department of Geography and Resource Management, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong, China
| | - Anita K Y Tsui
- Department of Early Childhood Education, The Hong Kong Institute of Education, Tai Po, N.T., Hong Kong, China
| | - Xun-Wen Chen
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| |
Collapse
|
24
|
Cavaleiro Rufo J, Madureira J, Paciência I, Slezakova K, Pereira MDC, Aguiar L, Teixeira JP, Moreira A, Oliveira Fernandes E. Children exposure to indoor ultrafine particles in urban and rural school environments. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:13877-13885. [PMID: 27040535 DOI: 10.1007/s11356-016-6555-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Accepted: 03/23/2016] [Indexed: 06/05/2023]
Abstract
Extended exposure to ultrafine particles (UFPs) may lead to consequences in children due to their increased susceptibility when compared to older individuals. Since children spend in average 8 h/day in primary schools, assessing the number concentrations of UFPs in these institutions is important in order to evaluate the health risk for children in primary schools caused by indoor air pollution. Thus, the purpose of this study was to assess and determine the sources of indoor UFP number concentrations in urban and rural Portuguese primary schools. Indoor and outdoor ultrafine particle (UFP) number concentrations were measured in six urban schools (US) and two rural schools (RS) located in the north of Portugal, during the heating season. The mean number concentrations of indoor UFPs were significantly higher in urban schools than in rural ones (10.4 × 10(3) and 5.7 × 10(3) pt/cm(3), respectively). Higher UFP levels were associated with higher squared meters per student, floor levels closer to the ground, chalk boards, furniture or floor covering materials made of wood and windows with double-glazing. Indoor number concentrations of ultrafine-particles were inversely correlated with indoor CO2 levels. In the present work, indoor and outdoor concentrations of UFPs in public primary schools located in urban and rural areas were assessed, and the main sources were identified for each environment. The results not only showed that UFP pollution is present in augmented concentrations in US when compared to RS but also revealed some classroom/school characteristics that influence the concentrations of UFPs in primary schools.
Collapse
Affiliation(s)
- João Cavaleiro Rufo
- INEGI, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal.
- Faculty of Medicine of the University of Porto, Al. Prof. Hernâni Monteiro, 4200-319, Porto, Portugal.
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal.
| | | | - Inês Paciência
- INEGI, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- Faculty of Medicine of the University of Porto, Al. Prof. Hernâni Monteiro, 4200-319, Porto, Portugal
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal
| | - Klara Slezakova
- LEPABE, Faculty of Engineering of University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Maria do Carmo Pereira
- LEPABE, Faculty of Engineering of University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Lívia Aguiar
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal
- National Institute of Health, Rua Alexandre Herculano, 321, 4200-055, Porto, Portugal
| | - João Paulo Teixeira
- Epidemiology Research Unit - Institute of Public Health (EPIUnit), University of Porto, Rua das Taipas n°135, Porto, 4050-600, Portugal
- National Institute of Health, Rua Alexandre Herculano, 321, 4200-055, Porto, Portugal
| | - André Moreira
- Faculty of Medicine of the University of Porto, Al. Prof. Hernâni Monteiro, 4200-319, Porto, Portugal
| | | |
Collapse
|
25
|
Branco PTBS, Nunes RAO, Alvim-Ferraz MCM, Martins FG, Sousa SIV. Children's exposure to indoor air in urban nurseries--Part II: Gaseous pollutants' assessment. ENVIRONMENTAL RESEARCH 2015; 142:662-670. [PMID: 26342590 DOI: 10.1016/j.envres.2015.08.026] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Revised: 08/24/2015] [Accepted: 08/25/2015] [Indexed: 06/05/2023]
Abstract
This study, Part II of the larger study "Children's exposure to indoor air in urban nurseries", aimed to: (i) evaluate nursery schools' indoor concentrations of several air pollutants in class and lunch rooms; and (ii) analyse them according to guidelines and references. Indoor continuous measurements were performed, and outdoor concentrations were obtained to determine indoor/outdoor ratios. The influence of outdoor air seemed to be determinant on carbon monoxide (CO), nitrogen dioxide (NO2) and ozone (O3) indoor concentrations. The peak concentrations of formaldehyde and volatile organic compounds (VOC) registered (highest concentrations of 204 and 2320 µg m(-3) respectively), indicated the presence of specific indoor sources of these pollutants, namely materials emitting formaldehyde and products emitting VOC associated to cleaning and children's specific activities (like paints and glues). For formaldehyde, baseline constant concentrations along the day were also found in some of the studied rooms, which enhances the importance of detailing the study of children's short and long-term exposure to this indoor air pollutant. While CO, NO2 and O3 never exceeded the national and international reference values for IAQ and health protection, exceedances were found for formaldehyde and VOC. For this reason, a health risk assessment approach could be interesting for future research to assess children's health risks of exposure to formaldehyde and to VOC concentrations in nursery schools. Changing cleaning schedules and materials emitting formaldehyde, and more efficient ventilation while using products emitting VOC, with the correct amount and distribution of fresh air, would decrease children's exposure.
Collapse
Affiliation(s)
- P T B S Branco
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - R A O Nunes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - M C M Alvim-Ferraz
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - F G Martins
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - S I V Sousa
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| |
Collapse
|
26
|
Wangchuk T, Mazaheri M, Clifford S, Dudzinska MR, He C, Buonanno G, Morawska L. Children's personal exposure to air pollution in rural villages in Bhutan. ENVIRONMENTAL RESEARCH 2015; 140:691-698. [PMID: 26087435 DOI: 10.1016/j.envres.2015.06.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 05/28/2015] [Accepted: 06/02/2015] [Indexed: 06/04/2023]
Abstract
Exposure assessment studies conducted in developing countries have been based on fixed-site monitoring to date. This is a major deficiency, leading to errors in estimating the actual exposures, which are a function of time spent and pollutant concentrations in different microenvironments. This study quantified school children's daily personal exposure to ultrafine particles (UFP) using real-time monitoring, as well as volatile organic compounds (VOCs) and NO2 using passive sampling in rural Bhutan in order to determine the factors driving the exposures. An activity diary was used to track children's time activity patterns, and difference in mean exposure levels across sex and indoor/outdoor were investigated with ANOVA. 82 children, attending three primary schools participated in this study; S1 and S2 during the wet season and S3 during the dry season. Mean daily UFP exposure (cm(-3)) was 1.08×10(4) for children attending S1, 9.81×10(3) for S2, and 4.19×10(4) for S3. The mean daily NO2 exposure (µg m(-3)) was 4.27 for S1, 3.33 for S2 and 5.38 for S3 children. Likewise, children attending S3 also experienced higher daily exposure to a majority of the VOCs than those attending S1 and S2. Time-series of UFP personal exposures provided detailed information on identifying sources of these particles and quantifying their contributions to the total daily exposures for each microenvironment. The highest UFP exposure resulted from cooking/eating, contributing to 64% of the daily exposure, due to firewood combustion in houses using traditional mud cookstoves. The lowest UFP exposures were during the hours that children spent outdoors at school. The outcomes of this study highlight the significant contributions of lifestyle and socio-economic factors in personal exposures and have applications in environmental risk assessment and household air pollution mitigation in Bhutan.
Collapse
Affiliation(s)
- Tenzin Wangchuk
- Department of Environmental Science, Sherubtse College, Royal University of Bhutan, Trashigang, Bhutan.
| | - Mandana Mazaheri
- International Laboratory for Air Quality and Health, Institute of Health and Biomedical Innovation, Queensland University of Technology, 2 George Street, Brisbane 4001, Australia
| | - Sam Clifford
- International Laboratory for Air Quality and Health, Institute of Health and Biomedical Innovation, Queensland University of Technology, 2 George Street, Brisbane 4001, Australia; Institute for Future Environments, Queensland University of Technology, 2 George St, Brisbane 4001, Australia
| | - Marzenna R Dudzinska
- Faculty of Environmental Engineering, Lublin University of Technology, Lublin, Poland
| | - Congrong He
- International Laboratory for Air Quality and Health, Institute of Health and Biomedical Innovation, Queensland University of Technology, 2 George Street, Brisbane 4001, Australia
| | - Giorgio Buonanno
- International Laboratory for Air Quality and Health, Institute of Health and Biomedical Innovation, Queensland University of Technology, 2 George Street, Brisbane 4001, Australia; Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, Italy
| | - Lidia Morawska
- International Laboratory for Air Quality and Health, Institute of Health and Biomedical Innovation, Queensland University of Technology, 2 George Street, Brisbane 4001, Australia
| |
Collapse
|
27
|
Branco PTBS, Alvim-Ferraz MCM, Martins FG, Sousa SIV. Children's exposure to indoor air in urban nurseries-part I: CO₂ and comfort assessment. ENVIRONMENTAL RESEARCH 2015; 140:1-9. [PMID: 25800634 DOI: 10.1016/j.envres.2015.03.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 03/10/2015] [Accepted: 03/11/2015] [Indexed: 06/04/2023]
Abstract
Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study "Children's exposure to indoor air in urban nurseries", aimed to: i) evaluate nurseries' indoor concentrations of carbon dioxide (CO2), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters-temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO2 concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health.
Collapse
Affiliation(s)
- P T B S Branco
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, E215, Porto, Portugal
| | - M C M Alvim-Ferraz
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, E215, Porto, Portugal
| | - F G Martins
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, E215, Porto, Portugal
| | - S I V Sousa
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, E215, Porto, Portugal.
| |
Collapse
|
28
|
Nunes RAO, Branco PTBS, Alvim-Ferraz MCM, Martins FG, Sousa SIV. Particulate matter in rural and urban nursery schools in Portugal. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2015; 202:7-16. [PMID: 25795175 DOI: 10.1016/j.envpol.2015.03.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 03/09/2015] [Accepted: 03/10/2015] [Indexed: 06/04/2023]
Abstract
Studies have been showing strong associations between exposures to indoor particulate matter (PM) and health effects on children. Urban and rural nursery schools have different known environmental and social differences which make their study relevant. Thus, this study aimed to evaluate indoor PM concentrations on different microenvironments of three rural nursery schools and one urban nursery school, being the only study comparing urban and rural nursery schools considering the PM1, PM2.5 and PM10 fractions (measured continuously and in terms of mass). Outdoor PM2.5 and PM10 were also obtained and I/O ratios have been determined. Indoor PM mean concentrations were higher in the urban nursery than in rural ones, which might have been related to traffic emissions. However, I/O ratios allowed concluding that the recorded concentrations depended more significantly of indoor sources. WHO guidelines and Portuguese legislation exceedances for PM2.5 and PM10 were observed mainly in the urban nursery school.
Collapse
Affiliation(s)
- R A O Nunes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - P T B S Branco
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - M C M Alvim-Ferraz
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - F G Martins
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - S I V Sousa
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| |
Collapse
|
29
|
Rufo JC, Madureira J, Paciência I, Slezakova K, Pereira MDC, Pereira C, Teixeira JP, Pinto M, Moreira A, Fernandes EDO. Exposure of Children to Ultrafine Particles in Primary Schools in Portugal. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2015; 78:904-914. [PMID: 26167756 DOI: 10.1080/15287394.2015.1048866] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Children spend a large part of their time at schools, which might be reflected as chronic exposure. Ultrafine particles (UFP) are generally associated with a more severe toxicity compared to fine and coarse particles, due to their ability to penetrate cell membranes. In addition, children tend to be more susceptible to UFP-mediated toxicity compared to adults, due to various factors including undeveloped immune and respiratory systems and inhalation rates. Thus, the purpose of this study was to determine indoor UFP number concentrations in Portuguese primary schools. Ultrafine particles were sampled between January and March 2014 in 10 public primary schools (35 classrooms) located in Porto, Portugal. Overall, the average indoor UFP number concentrations were not significantly different from outdoor concentrations (8.69 × 10(3) vs. 9.25 × 10(3) pt/cm(3), respectively; considering 6.5 h of indoor occupancy). Classrooms with distinct characteristics showed different trends of indoor UFP concentrations. The levels of carbon dioxide were negatively correlated with indoor UFP concentrations. Occupational density was significantly and positively correlated with UFP concentrations. Although the obtained results need to be interpreted with caution since there are no guidelines for UFP levels, special attention needs to be given to source control strategies in order to reduce major particle emissions and ensure good indoor air quality.
Collapse
Affiliation(s)
- João Cavaleiro Rufo
- a Institute of Mechanical Engineering and Industrial Management , Porto , Portugal
| | | | | | | | | | | | | | | | | | | |
Collapse
|