1
|
Arcas-Carbonell M, Orduna-Hospital E, Fernández-Espinosa G, Mechó-García M, Castro-Torres JJ, Sánchez-Cano A. Anterior Chamber and Retinal Morphological Changes During Accommodation in Different Age Ranges. Curr Eye Res 2024; 49:671-681. [PMID: 38379315 DOI: 10.1080/02713683.2024.2320771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/13/2024] [Indexed: 02/22/2024]
Abstract
PURPOSE Accommodation mainly affects the lens, a structure of the eyeball that degrades with age. The aim of this work was to study the morphological changes of different ocular structures during accommodation, both in the anterior pole and the posterior pole, which may also be involved in the accommodation process. METHODS The study will be carried out by stimulating accommodation through lenses of -1.00, -3.00 and -5.00 D starting from the spherical equivalent (M) of each participant in different age groups, from 18 to 66 years. To obtain the M value, aberrometry was achieved, and retinal optical coherence tomography and anterior pole tomography were performed to evaluate the possible structural modifications (central and peripheral), while accommodation was progressively stimulated. RESULTS It showed that as the accommodative demand increased, morphological changes were produced in retinal thickness, both in the central and peripheral retina, in all age groups. A thinning of the retina was observed in the central 3 mm, while significant progressive thickening was observed closer to the periphery (up to 6 mm from the fovea) as the required accommodative power increased. A decrease in the anterior chamber depth (ACD) and anterior chamber volume (ACV) was observed with increasing lens power. CONCLUSION Structural changes were observed in the central and peripheral retina, as well as in the ACD and ACV, while progressively greater accommodation was stimulated, showing that these structures were modified in the accommodation process even in advanced presbyopes.
Collapse
Affiliation(s)
| | | | | | - María Mechó-García
- Clinical & Experimental Optometry Research Lab, Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| | | | - Ana Sánchez-Cano
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
| |
Collapse
|
2
|
Davies LN, Biswas S, Bullimore M, Cruickshank F, Estevez JJ, Khanal S, Kollbaum P, Marcotte-Collard R, Montani G, Plainis S, Richdale K, Simard P, Wolffsohn JS. BCLA CLEAR presbyopia: Mechanism and optics. Cont Lens Anterior Eye 2024:102185. [PMID: 38796331 DOI: 10.1016/j.clae.2024.102185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2024]
Abstract
With over a billion adults worldwide currently affected, presbyopia remains a ubiquitous, global problem. Despite over a century of study, the precise mechanism of ocular accommodation and presbyopia progression remains a topic of debate. Accordingly, this narrative review outlines the lenticular and extralenticular components of accommodation together with the impact of age on the accommodative apparatus, neural control of accommodation, models of accommodation, the impact of presbyopia on retinal image quality, and both historic and contemporary theories of presbyopia.
Collapse
Affiliation(s)
- Leon N Davies
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK.
| | - Sayantan Biswas
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK
| | | | - Fiona Cruickshank
- Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, UK
| | - Jose J Estevez
- Caring Futures Institute, College of Nursing and Health Sciences, Optometry and Vision Science, Flinders University, Adelaide, Australia; Flinders Centre for Ophthalmology, Eye and Vision Research, Department of Ophthalmology, Flinders University, Adelaide, Australia
| | - Safal Khanal
- Department of Optometry and Vision Science, The University of Alabama at Birmingham, USA
| | | | | | | | - Sotiris Plainis
- Laboratory of Optics and Vision, School of Medicine, University of Crete, Greece
| | | | - Patrick Simard
- School of Optometry, Universite de Montreal, Montreal, Quebec, Canada
| | - James S Wolffsohn
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK
| |
Collapse
|
3
|
Dahaghin A, Salimibani M, Boszczyk A, Jóźwik A, Skrok M, Grasa J, Siedlecki D. Investigation of crystalline lens overshooting: ex vivo experiment and optomechanical simulation results. Front Bioeng Biotechnol 2024; 12:1348774. [PMID: 38655391 PMCID: PMC11035874 DOI: 10.3389/fbioe.2024.1348774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Accepted: 03/12/2024] [Indexed: 04/26/2024] Open
Abstract
Introduction: Crystalline lens overshooting refers to a situation in which the lens momentarily shifts too much from its typical location immediately after stopping the rotational movement of the eye globe. This movement can be observed using an optical technique called Purkinje imaging. Methods: In this work, an experimental setup was designed to reproduce this effect ex vivo using a fresh porcine eye. The sample was rotated 90° around its centroid using a high-velocity rotation stage, and the Purkinje image sequences were recorded, allowing us to quantify the overshooting effect. The numerical part of the study consisted of developing a computational model of the eye, based on the finite element method, that allowed us to understand the biomechanical behavior of the different tissues in this dynamic scenario. A 2D fluid-structure interaction model of the porcine eye globe, considering both the solid parts and humors, was created to reproduce the experimental outcomes. Results: Outputs of the simulation were analyzed using an optical simulation software package to assess whether the mechanical model behaves optically like the real ex vivo eye. The simulation predicted the experimental results by carefully adjusting the mechanical properties of the zonular fibers and the damping factor. Conclusion: This study effectively demonstrates the importance of characterizing the dynamic mechanical properties of the eye tissues to properly comprehend and predict the overshooting effect.
Collapse
Affiliation(s)
- Ali Dahaghin
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Milad Salimibani
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Agnieszka Boszczyk
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Agnieszka Jóźwik
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Marta Skrok
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| | - Jorge Grasa
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Damian Siedlecki
- Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
| |
Collapse
|
4
|
Ye L, Wang K, Grasa J, Pierscionek BK. The Effect of Lens Shape, Zonular Insertion and Finite Element Model on Simulated Shape Change of the Eye Lens. Ann Biomed Eng 2024:10.1007/s10439-024-03491-3. [PMID: 38503945 DOI: 10.1007/s10439-024-03491-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 03/11/2024] [Indexed: 03/21/2024]
Abstract
The process of lens shape change in the eye to alter focussing (accommodation) is still not fully understood. Modelling approaches have been used to complement experimental findings in order to determine how constituents in the accommodative process influence the shape change of the lens. An unexplored factor in modelling is the role of the modelling software on the results of simulated shape change. Finite element models were constructed in both Abaqus and Ansys software using biological parameters from measurements of shape and refractive index of two 35-year-old lenses. The effect of zonular insertion on simulated shape change was tested on both 35-year-old lens models and with both types of software. Comparative analysis of shape change, optical power, and stress distributions showed that lens shape and zonular insertion positions affect the results of simulated shape change and that Abaqus and Ansys show differences in their respective models. The effect of the software package used needs to be taken into account when constructing finite element models and deriving conclusions.
Collapse
Affiliation(s)
- Lin Ye
- Faculty of Health Education Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Chelmsford Campus, Chelmsford, UK
| | - Kehao Wang
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Engineering Medicine, Beihang University, Beijing, China
| | - Jorge Grasa
- Aragon Institute of Engineering Research (i3A), University of Zaragoza, Zaragoza, Spain
- Bioengineering, Biomaterials and Nanomedicine Networking Biomedical Research Centre (CIBER-BBN), Zaragoza, Spain
| | - Barbara K Pierscionek
- Faculty of Health Education Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Chelmsford Campus, Chelmsford, UK.
| |
Collapse
|
5
|
Liu Y, Liu L, Liu M, Wang X, Jin C, Ni B, Ke B. Change in three-dimensional choroidal vessel network after AR device assisted 1-hour visual task in 2D/3D mode in young healthy subjects. Acta Ophthalmol 2024; 102:e117-e125. [PMID: 37088997 DOI: 10.1111/aos.15671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/07/2023] [Accepted: 03/27/2023] [Indexed: 04/25/2023]
Abstract
PURPOSE The purpose of the study was to investigate the changes of choroidal blood perfusion in different layers and quadrants and its possible related factors after 1 h visual task by augmented reality (AR) device in two-dimensional (2D) and three-dimensional (3D) mode, respectively. METHODS Thirty healthy subjects aged 22-37 years watched the same video source in 2D and 3D mode separately using AR glasses for 1 h with a one-week interval. Swept-source optical coherence tomography angiography (SS-OCTA) was performed before and immediately after watching to acquire choroidal thickness (ChT), three-dimensional choroidal vascularity index (CVI) of large- and middle-sized choroidal vessels and choriocapillaris flow voids (FV%) at macular and peripapillary area. Near point of accommodation (NPA) and accommodative facility (AF) were examined to evaluate the accommodative ability. Pupil diameters by infrared-automated pupillometer under scotopic, mesopic and photopic condition were also obtained. RESULTS Compared with pre-visual task, the subfoveal CVI decreased from 0.406 ± 0.097 to 0.360 ± 0.102 after 2D watching (p < 0.001) and to 0.368 ± 0.102 after 3D watching (p = 0.002). Pupil sizes under different illuminance conditions became smaller after both 2D and 3D watching (all p < 0.001). AF increased after both 2D and 3D watching (both p < 0.05). NPA receded in post-3D watching (p = 0.017) while a not significant tendency was observed in post-2D. CONCLUSION A reduction in subfoveal choroidal blood flow accompanied with pupil constriction was observed immediately after 1 h visual task using AR glasses in 2D and 3D mode. Accommodative facility improved after 2D and 3D watching with AR glasses, whereas decrease in the maximum accommodation power was only found in 3D mode.
Collapse
Affiliation(s)
- Yuying Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Lu Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Mingming Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Xuetong Wang
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Chengcheng Jin
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Bingbing Ni
- Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Bilian Ke
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| |
Collapse
|
6
|
Korkmaz I, Esen Baris M, Guven Yilmaz S, Palamar M. Effect of Cycloplegia on Anterior Segment Structures and Scleral Thickness in Emmetropic Eyes. J Ocul Pharmacol Ther 2023; 39:699-704. [PMID: 37695817 DOI: 10.1089/jop.2023.0039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2023] Open
Abstract
Purpose: To evaluate the effects of topical cyclopentolate hydrochloride-induced cycloplegia on anterior segment biomechanics in emmetropic eyes using anterior segment-optical coherence tomography (AS-OCT). Methods: Twenty-five emmetropic eyes of 25 volunteers were included. All underwent central corneal thickness (CCT) and anterior chamber depth (ACD) measurements. Anterior scleral thickness (AST) was measured at the level of the scleral spur (SS)(AST-0), 1,000 μm posterior of the SS (AST-1), and 2,000 μm posterior of the SS (AST-2) in the nasal and temporal quadrants using AS-OCT. All measurements were repeated after cycloplegia. Results: The mean age was 30.6 ± 12.4 (8-45) years. The mean CCT did not significantly change after cycloplegia (P = 0.7). The mean ACD was significantly increased [3.3 ± 0.2 (2.7-3.9) to 3.7 ± 0.3 (3-4.2) μm; P = 0.001]. In the nasal quadrant, the mean AST-1 and AST-2 were 512.3 ± 34.4 (433-570) and 529.6 ± 34.2 (449-599); decreased to 478 ± 26.8 (423-530) and 486.2 ± 28.3 (422-544) μm, respectively, after cycloplegia (P = 0.00; P = 0.00). In the temporal quadrant, the mean AST-1 and AST-2 were 522.5 ± 24.7 (473-578) and 527.2 ± 39.9 (450-604); decreased to 481.1 ± 33.7 (421-550) and 484.6 ± 26.6 (433-528) μm, respectively (P = 0.00; P = 0.00). There was no significant difference in AST-0 after cycloplegia in both quadrants [from 697.5 ± 46 (605-785) to 709.5 ± 64.7 (565-785) for nasal and from 718.4 ± 40.1 (632-796) to 722.9 ± 60.6 (596-838) for temporal; P = 0.2; P = 0.3, respectively]. Conclusion: After cycloplegia, there was a significant thinning of ASTs posterior to SS and a slight increase in AST in the SS level. ACD deepened after cycloplegia, and there was no significant change in CCT. Cycloplegic agents temporarily inhibit ciliary muscle contraction and may affect anterior segment parameters and sclera. Inhibition of forward-inward movement of the ciliary body by cycloplegia affects ASTs and ACD by causing a change in the mechanical force of the ciliary muscle on the sclera.
Collapse
Affiliation(s)
- Ilayda Korkmaz
- Department of Ophthalmology, Ege University Medical Faculty Hospital, Izmir, Turkey
| | - Mine Esen Baris
- Department of Ophthalmology, Ege University Medical Faculty Hospital, Izmir, Turkey
| | - Suzan Guven Yilmaz
- Department of Ophthalmology, Ege University Medical Faculty Hospital, Izmir, Turkey
| | - Melis Palamar
- Department of Ophthalmology, Ege University Medical Faculty Hospital, Izmir, Turkey
| |
Collapse
|
7
|
Goswami S, Bharadwaj SR. Temporal fluctuations in defocus may reverse the acuity loss encountered with induced refractive errors. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2023; 40:2008-2018. [PMID: 38038066 DOI: 10.1364/josaa.497091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 10/02/2023] [Indexed: 12/02/2023]
Abstract
A recent template-matching model hypothesized that simulated visual acuity loss with uncorrected refractive errors may be recovered by adding temporal defocus fluctuations up to the magnitude of the refractive error. Acuity recovery saturates or gets attenuated beyond this magnitude. These predictions were confirmed for monocular high-contrast visual acuity of 10 young, cyclopleged adults with 0.5-2.0D of induced myopia combined with the same range of temporal defocus fluctuations at 4.0 Hz frequency. The outcomes reinforce that spatial resolution may be optimized by averaging time-varying defocus over the entire stimulus presentation epoch or around the point of least defocus within this epoch.
Collapse
|
8
|
Rodriguez-Lopez V, Hernandez-Poyatos A, Dorronsoro C. Defocus flicker of chromatic stimuli deactivates accommodation. BIOMEDICAL OPTICS EXPRESS 2023; 14:3671-3688. [PMID: 37497489 PMCID: PMC10368037 DOI: 10.1364/boe.486466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/20/2023] [Accepted: 05/20/2023] [Indexed: 07/28/2023]
Abstract
Tunable lenses, optical elements able to change their optical power within milliseconds, constitute an emerging technology increasingly used in ophthalmic applications. In this study, 25 subjects looked through tunable lenses at a chromatic stimulus to evaluate the perceptual response of the human visual system to periodic changes in defocus of 0.25D of amplitude and 15 Hz of temporal frequency. These defocus changes produce flicker and chromatic distortions that change with the overall level of defocus. The task in this study was to minimize the flicker by varying the average optical power, and it was performed for different myopic and hyperopic starting points. Subjects also performed a blur-minimization task in a black-and-white stimulus of the same geometry. The flicker-minimization task is more repeatable than the blur-minimization task (standard deviations ±0.17D and ±0.49D). The time per repetition of the flicker-minimization task is only 38s. Cycloplegia severely affects the blur-minimization, but not the flicker-minimization task, confirming that defocus flicker deactivates the accommodative system. This discovery can be used to develop new methods for measuring the refractive error of the eye that does not require supervision and can potentially improve existing subjective methods in terms of accuracy, precision, and measurement time.
Collapse
Affiliation(s)
- Victor Rodriguez-Lopez
- Institute of Optics, Spanish National Research Council (IO-CSIC), IO-CSIC, Serrano 121, E-28006, Madrid, Spain
| | - Alfonso Hernandez-Poyatos
- Institute of Optics, Spanish National Research Council (IO-CSIC), IO-CSIC, Serrano 121, E-28006, Madrid, Spain
| | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council (IO-CSIC), IO-CSIC, Serrano 121, E-28006, Madrid, Spain
- 2EyesVision SL, Plaza de la Encina, 10, núcleo 3, planta 4ª, E-28760 Tres Cantos, Madrid, Spain
| |
Collapse
|
9
|
Panagiotopoulou EK, Boboridis K, Seimenis I, Labiris G. Impact of Light Conditions on Visual Performance following Premium Pseudophakic Presbyopia Corrections. J Clin Med 2023; 12:4324. [PMID: 37445358 DOI: 10.3390/jcm12134324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/13/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023] Open
Abstract
The primary objective of this study was to objectively compare the visual performance of patients following premium pseudophakic presbyopia corrections in different light combinations for near- and intermediate-vision activities of daily living (ADLs). This is a prospective, comparative study. A total of 75 patients populated three study groups: G1-patients with bilateral trifocal implantation, G2-patients with bilateral bifocal implantation, and G3-patients with bilateral monofocal implantation. All participants addressed 10 ADLs in nine combinations of light temperature (3000 K, 4000 K, and 6000 K) and light intensity (25 fc, 50 fc, and 75 fc) and declared their subjectively optimal light combination while reading. G2 and G3 had the best total ADL scores in 6000 K/75 fc, while G1 had the best total ADL score in 4000 K/75 fc. Total ADL, easy ADL, and moderate difficulty ADL scores were significantly better in G2, while difficult ADL score was significantly better in G1. The majority of all groups selected 6000 K/75 fc as the most comfortable light combination, and no group selected 3000 K and 25 fc. In conclusion, trifocal patients benefit from intense daylight, while bifocal and monofocal patients benefit from intense, cold lighting. Trifocal patients present superior near-vision capacity in difficult near-vision daily tasks, while bifocal patients present superiority in easy and moderate-difficulty ADLs.
Collapse
Affiliation(s)
| | - Kostas Boboridis
- Ophthalmology Department, AHEPA University Hospital, 54636 Thessaloniki, Greece
| | - Ioannis Seimenis
- Medical Physics Laboratory, School of Medicine, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Georgios Labiris
- Department of Ophthalmology, University Hospital of Alexandroupolis, 68100 Alexandroupolis, Greece
| |
Collapse
|
10
|
Souchet AD, Lourdeaux D, Burkhardt JM, Hancock PA. Design guidelines for limiting and eliminating virtual reality-induced symptoms and effects at work: a comprehensive, factor-oriented review. Front Psychol 2023; 14:1161932. [PMID: 37359863 PMCID: PMC10288216 DOI: 10.3389/fpsyg.2023.1161932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 05/16/2023] [Indexed: 06/28/2023] Open
Abstract
Virtual reality (VR) can induce side effects known as virtual reality-induced symptoms and effects (VRISE). To address this concern, we identify a literature-based listing of these factors thought to influence VRISE with a focus on office work use. Using those, we recommend guidelines for VRISE amelioration intended for virtual environment creators and users. We identify five VRISE risks, focusing on short-term symptoms with their short-term effects. Three overall factor categories are considered: individual, hardware, and software. Over 90 factors may influence VRISE frequency and severity. We identify guidelines for each factor to help reduce VR side effects. To better reflect our confidence in those guidelines, we graded each with a level of evidence rating. Common factors occasionally influence different forms of VRISE. This can lead to confusion in the literature. General guidelines for using VR at work involve worker adaptation, such as limiting immersion times to between 20 and 30 min. These regimens involve taking regular breaks. Extra care is required for workers with special needs, neurodiversity, and gerontechnological concerns. In addition to following our guidelines, stakeholders should be aware that current head-mounted displays and virtual environments can continue to induce VRISE. While no single existing method fully alleviates VRISE, workers' health and safety must be monitored and safeguarded when VR is used at work.
Collapse
Affiliation(s)
- Alexis D. Souchet
- Heudiasyc UMR 7253, Alliance Sorbonne Université, Université de Technologie de Compiègne, CNRS, Compiègne, France
- Institute for Creative Technologies, University of Southern California, Los Angeles, CA, United States
| | - Domitile Lourdeaux
- Heudiasyc UMR 7253, Alliance Sorbonne Université, Université de Technologie de Compiègne, CNRS, Compiègne, France
| | | | - Peter A. Hancock
- Department of Psychology, University of Central Florida, Orlando, FL, United States
| |
Collapse
|
11
|
Goswami S, Bharadwaj SR. Impact of temporal fluctuations in optical defocus on visual acuity: Empirical results and modeling outcomes. J Vis 2023; 23:14. [PMID: 36971683 PMCID: PMC10064932 DOI: 10.1167/jov.23.3.14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
Optical defocus in human eyes is seldom steady during naturalistic steady-state viewing. It fluctuates by 0.3 to 0.5 diopters (D) from accommodative microfluctuations and by 1.5 to 2.5 D in dysfunctions such as spasm of near reflex, both with ≤2 Hz low-pass frequency spectra. This study observed losses in monocular visual acuity of cyclopleged adults who encountered varying amplitude (0.25-2.0 D) and temporal frequency (0.25-2.0 Hz) combinations of sinusoidal defoci induced using an electrically tunable lens. Visual acuity, recorded for 300-ms flashes of Sloan optotype presentation using the method of constant stimuli, deteriorated with defocus amplitude at a rate steeper for lower than higher temporal frequencies. A template matching model of acuity, incorporating optical and neural low-pass filters, neural noise, and a cross-correlated decision operator, showed the best match with empirical data when acuity was governed by the minimum defocus available during optotype display. This criterion minimized acuity loss for higher temporal frequencies due to the increased probability of zero-defocus encounters within the presentation duration. Other decision criteria such as defocus averaging across the entire or parts of the presentation duration yielded less satisfactory results. These results imply that vision loss in humans encountering broadband time-varying defocus is dictated by the dominant low frequencies, with higher frequencies largely compensated using the least defocus decision strategy.
Collapse
Affiliation(s)
- Sabyasachi Goswami
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, Telangana, India
- Prof Brien Holden Eye Research Centre, Hyderabad Eye Research Foundation, L V Prasad Eye Institute, Hyderabad, Telangana, India
| | - Shrikant R Bharadwaj
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, Telangana, India
- Prof Brien Holden Eye Research Centre, Hyderabad Eye Research Foundation, L V Prasad Eye Institute, Hyderabad, Telangana, India
| |
Collapse
|
12
|
Design of an Automatically Controlled Multi-Axis Stretching Device for Mechanical Evaluations of the Anterior Eye Segment. Bioengineering (Basel) 2023; 10:bioengineering10020142. [PMID: 36829636 PMCID: PMC9952546 DOI: 10.3390/bioengineering10020142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/14/2023] [Accepted: 01/18/2023] [Indexed: 01/22/2023] Open
Abstract
The young eye has an accommodative ability involving lens shape changes to focus over different distances. This function gradually decreases with age, resulting in presbyopia. Greater insights into the mechanical properties of anterior eye structures can improve understanding of the causes of presbyopia. The present study aims to develop a multi-axis stretching device for evaluating the mechanical properties of the intact eye lens. A stretching device integrating the mechanical stretcher, motor, torque sensor and data transmission mechanism was designed and developed by 3D printing. The mechanical stretcher can convert rotation into radial movement, both at constant speeds, according to the spiral of Archimedes. The loading unit equipped with eight jaws can hold the eye sample tightly. The developed device was validated with a spring of known constant and was further tested with anterior porcine eye segments. The validation experiment using the spring resulted in stiffness values close to the theoretical spring constant. Findings from measurements with porcine eye samples indicated that the measured forces are within the ranges reported in the literature. The developed multi-axis stretching device has good repeatability during experiments with similar settings and can be reliably used for mechanical evaluations of the intact eye lens.
Collapse
|
13
|
Roorda A, Tiruveedhula P, Naseri A, Rhee P, Clarke M. FIAT: A Device for Objective, Optical Measures of Accommodation in Phakic and Pseudophakic Eyes. Transl Vis Sci Technol 2023; 12:9. [PMID: 36607622 PMCID: PMC9836010 DOI: 10.1167/tvst.12.1.9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Purpose To present FIAT, a novel optical instrument and analysis package that is designed to elicit and optically record accommodation in human eyes. Methods FIAT employs a Shack-Hartmann wavefront sensor and a retro-illumination pupil camera that records from a single eye at video rates. It is effective at eliciting accommodation by offering the subject a full-field binocular view of an alternating distant target and a near-eye display. FIAT analysis software computes wave aberrations for each video frame over full- or subpupil sizes and computes accommodative dynamics and accommodative range. Results The system is validated by showing accurate refraction measurements in model eyes and human eyes with trial lenses. Robust accommodative responses are shown for young eyes, and a lack of accommodative response is shown for a known presbyopes. Accommodative stimulus-response curves from five phakic subjects over a range of ages show expected results. Results from two individuals with monofocal intraocular lenses are shown. Conclusions FIAT is an effective instrument for making accurate, objective measures of accommodation in phakic and pseudophakic eyes. Translational Relevance We present a device that can play an important role in the development and testing of accommodating intraocular lenses.
Collapse
Affiliation(s)
- Austin Roorda
- University of California at Berkeley, Berkeley, CA, USA
| | | | - Ayman Naseri
- ForSight VISION6, Inc. South San Francisco, CA, USA,University of California, San Francisco, San Francisco, CA, USA
| | - Paul Rhee
- ForSight VISION6, Inc. South San Francisco, CA, USA
| | - Matt Clarke
- ForSight VISION6, Inc. South San Francisco, CA, USA
| |
Collapse
|
14
|
Wolffsohn JS, Davies LN, Sheppard AL. New insights in presbyopia: impact of correction strategies. BMJ Open Ophthalmol 2023. [DOI: 10.1136/bmjophth-2022-001122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Presbyopia occurs when the physiologically normal age-related reduction in the eyes focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual’s requirements. Hence, it is more about the impact it has on an individual’s visual ability to function in their environment to maintain their lifestyle than a measured loss of focusing ability. Presbyopia has a significant impact on an individual’s quality of life and emotional state. While a range of amelioration strategies exist, they are often difficult to access in the developing world and prescribing is generally not optimal even in developed countries. This review identified the need for a standardised definition of presbyopia to be adopted. An appropriate battery of tests should be applied in evaluating presbyopic management options and the results of clinical trials should be published (even if unsuccessful) to accelerate the provision of better outcomes for presbyopes.
Collapse
|
15
|
Regulation of lens water content: Effects on the physiological optics of the lens. Prog Retin Eye Res 2022:101152. [DOI: 10.1016/j.preteyeres.2022.101152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 11/21/2022] [Accepted: 11/22/2022] [Indexed: 12/09/2022]
|
16
|
Chen Y, Ye S, Wang Q, Shen M, Lu F, Qu J, Zhu D. In situ assessment of lens elasticity with noncontact optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2022; 13:6671-6681. [PMID: 36589560 PMCID: PMC9774883 DOI: 10.1364/boe.475306] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 11/16/2022] [Accepted: 11/17/2022] [Indexed: 06/17/2023]
Abstract
Lens biomechanics has great potential for application in clinical diagnostics and treatment monitoring of presbyopia and cataracts. However, current approaches to lens elastography do not meet the desired safety or sensitivity for clinical application. In this regard, we propose a noncontact optical coherence elastography (OCE) method to facilitate quantitative in situ imaging of lens elasticity. Elastic waves induced by air-pulse stimulation on the limbus propagate to the lens and are then imaged using custom-built swept-source optical coherence tomography to obtain the elastic wave velocity and Young's modulus. The proposed OCE method was first validated by comparing the results of in situ and in vitro measurements of porcine lenses. The results demonstrate that the Young's modulus measured in situ was highly consistent with that measured in vitro and had an intraclass correlation coefficient of 0.988. We further investigated the elastic changes induced by cold storage and microwave heating. During 36-hour cold storage, the mean Young's modulus gradually increased (from 5.62 ± 1.24 kPa to 11.40 ± 2.68 kPa, P < 0.0001, n = 9) along with the formation of nuclear opacities. 15-second microwave heating caused a greater increase in the mean Young's modulus (from 6.86 ± 1.21 kPa to 25.96 ± 8.64 kPa, P < 0.0025, n = 6) without apparent cataract formation. Accordingly, this study reports the first air-pulse OCE measurements of in situ lenses, which quantified the loss of lens elasticity during simulated cataract development with good repeatability and sensitivity, thus enhancing the potential for adoption of lens biomechanics in the clinic.
Collapse
Affiliation(s)
- Yulei Chen
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Shuling Ye
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Qingying Wang
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Meixiao Shen
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Fan Lu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Jia Qu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Dexi Zhu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| |
Collapse
|
17
|
Kaphle D, Varnas SR, Schmid KL, Suheimat M, Leube A, Atchison DA. Accommodation lags are higher in myopia than in emmetropia: Measurement methods and metrics matter. Ophthalmic Physiol Opt 2022; 42:1103-1114. [PMID: 35775299 PMCID: PMC9544228 DOI: 10.1111/opo.13021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 05/31/2022] [Accepted: 05/31/2022] [Indexed: 12/29/2022]
Abstract
Purpose To determine whether accommodative errors in emmetropes and myopes are systematically different, and the effect of using different instruments and metrics. Methods Seventy‐six adults aged 18–27 years comprising 24 emmetropes (spherical equivalent refraction of the dominant eye +0.04 ± 0.03 D) and 52 myopes (−2.73 ± 0.22 D) were included. Accommodation responses were measured with a Grand Seiko WAM‐5500 and a Hartmann–Shack Complete Ophthalmic Analysis System aberrometer, using pupil plane (Zernike and Seidel refraction) and retinal image plane (neural sharpness—NS; and visual Strehl ratio for modulation transfer function—VSMTF) metrics at 40, 33 and 25 cm. Accommodation stimuli were presented to the corrected dominant eye, and responses, referenced to the corneal plane, were determined in the fellow eye. Linear mixed‐effects models were used to determine influence of the refractive group, the measurement method, accommodation stimulus, age, race, parental myopia, gender and binocular measures of heterophoria, accommodative convergence/accommodation and convergence accommodation/convergence ratios. Results Lags of accommodation were affected significantly by the measurement method (p < 0.001), the refractive group (p = 0.003), near heterophoria (p = 0.002) and accommodative stimulus (p < 0.05), with significant interactions between some of these variables. Overall, emmetropes had smaller lags of accommodation than myopes with respective means ± standard errors of 0.31 ± 0.08 D and 0.61 ± 0.06 D (p = 0.003). Lags were largest for the Grand Seiko and Zernike defocus, intermediate for NS and VSMTF, and least for Seidel defocus. Conclusions The mean lag of accommodation in emmetropes is approximately equal to the previously reported depth of focus. Myopes had larger (double) lags than emmetropes. Differences between methods and instruments could be as great as 0.50 D, and this must be considered when comparing studies and outcomes. Accommodative lag increased with the accommodation stimulus, but only for methods using a fixed small pupil diameter.
Collapse
Affiliation(s)
- Dinesh Kaphle
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.,Discipline of Optometry, Faculty of Health, University of Canberra, Canberra, Australian Capital Territory, Australia
| | - Saulius R Varnas
- Carl Zeiss Vision Australia Holdings Limited, Adelaide, South Australia, Australia
| | - Katrina L Schmid
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Marwan Suheimat
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | | | - David A Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| |
Collapse
|
18
|
Warjri GB, Senthil S. Imaging of the Ciliary Body: A Major Review. Semin Ophthalmol 2022; 37:711-723. [PMID: 35695216 DOI: 10.1080/08820538.2022.2085515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE We conducted a systematic search of literature to understand the various methods of imaging of the ciliary body. METHODS PubMed, Science Direct, Cochrane Library and Google Scholar were searched comprehensively and systematically to find studies related to the various modalities of ciliary body imaging. RESULTS The various ciliary body parameters that have been described are Ciliary body thickness, Ciliary body length, ciliary muscle thickness, ciliary process length, ciliary muscle length, ciliary muscle anterior length, trabecular ciliary process distance and Iris ciliary process distance. The various angles which have been measured, which mostly have a significance in Primary angle closure glaucoma (PACG) are Iris ciliary angle, Trabecular ciliary angle, scleral ciliary process angle. Various authors have defined them in various ways with subtle differences. Plateau iris and PACG mechanisms, not forgetting malignant glaucoma are better understood with imaging of the ciliary body using the ultrasound biomicroscopy (UBM). The anterior segment optical coherence tomography (ASOCT) imaging of the ciliary body has been described albeit with its own disadvantages. A few other fields dependant on the importance of ciliary body imaging are intravitreal injections, pars plana vitrectomy, measurements for implantable collamer lens (ICL) and of utmost importance, the differentiating features of ciliary body masses. CONCLUSION The UBM is still preferred over the ASOCT for imaging of the ciliary body. A lot of lacunae of knowledge still exists and consensus has to be reached on defining all the parameters universally. Future studies will be able to shed more light on the role of the ciliary body in the many ocular disorders mentioned in this review.
Collapse
Affiliation(s)
| | - Sirisha Senthil
- VST Centre for Glaucoma Services, L V Prasad Eye Institute, Hyderabad, India
| |
Collapse
|
19
|
Schumayer S, Simon N, Sittkus B, Wagner S, Bucher V, Strasser T. Novel Three-Dimensional and Biocompatible Lift-Off Method for Selective Metallization of a Scleral Contact Lens Electrode for Biopotential Detection. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:920384. [PMID: 35756534 PMCID: PMC9226725 DOI: 10.3389/fmedt.2022.920384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 05/23/2022] [Indexed: 11/13/2022] Open
Abstract
Presbyopia describes the eye's physiological loss of the ability to see close objects clearly. The adaptation to different viewing distances, termed accommodation, is achieved by a change in the curvature of the eye lens induced by the ciliary muscle. A possible approach to correct presbyopia could be to detect the ciliary muscle's neuromuscular signals during accommodation and transfer these signals electronically to a biomimetic, micro-optical system to provide the necessary refractive power. As a preliminary step toward such a described system, a novel three-dimensional and biocompatible lift-off method was developed. In addition, the influence of the distance between the electrically conducting surfaces of the lens on the accommodated signal amplitudes was investigated. Compared to the conventional masking methods, this process has the advantage that three-dimensional surfaces can be masked with biocompatible gelling sugar by utilizing a direct writing process with a dispensing robot. Since gelling sugar can be used at room temperature and is water-soluble, the process presented is suitable for materials that should not be exposed to organic solvents or excessively high temperatures. Apart from investigating the shrinkage behavior of the gelling sugar during the physical vapor deposition (PVD) coating process, this paper also describes the approaches used to partially coat a commercial scleral contact lens with an electrically conductive material. It was shown that gelling sugar withstands the conditions during the PVD processes and a successful lift-off was performed. To investigate the influence of the spacing between the electrically conductive regions of the contact lens on the measured signals, three simplified electrode configurations with different distances were fabricated using a 3D printer. By testing these in an experimental setup, it could be demonstrated that the distance between the conductive surfaces has a significant influence on the amplitude. Regarding the described lift-off process using gelling sugar, it was found that the dispensing flow rate has a direct influence on the line uniformity. Future work should address the influence of the viscosity of the gelling sugar as well as the diameter of the cannula. It is assumed that they are the prevailing limitations for the lateral resolution.
Collapse
Affiliation(s)
- Sven Schumayer
- Institute of Microsystems Technology, Furtwangen University, Furtwangen, Germany
- Institute for Ophthalmic Research, University of Tuebingen, Tuebingen, Germany
| | - Nicolai Simon
- Institute of Microsystems Technology, Furtwangen University, Furtwangen, Germany
- IMTEK—Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Benjamin Sittkus
- Institute of Microsystems Technology, Furtwangen University, Furtwangen, Germany
- IMTEK—Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Sandra Wagner
- Institute for Ophthalmic Research, University of Tuebingen, Tuebingen, Germany
| | - Volker Bucher
- Institute of Microsystems Technology, Furtwangen University, Furtwangen, Germany
- *Correspondence: Volker Bucher
| | - Torsten Strasser
- Institute for Ophthalmic Research, University of Tuebingen, Tuebingen, Germany
- University Eye Hospital Tuebingen, Tuebingen, Germany
| |
Collapse
|
20
|
Kaphle D, Schmid KL, Davies LN, Suheimat M, Atchison DA. Ciliary Muscle Dimension Changes With Accommodation Vary in Myopia and Emmetropia. Invest Ophthalmol Vis Sci 2022; 63:24. [PMID: 35749128 PMCID: PMC9234357 DOI: 10.1167/iovs.63.6.24] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Purpose The purpose of this study was to determine whether accommodation-induced changes in ciliary muscle dimensions vary between emmetropes and myopes, and the effect of the image analysis method. Methods Seventy adults aged 18 to 27 years consisted of 25 people with emmetropia (spherical equivalent refraction [SER] +0.21 ± 0.36 diopters [D]) and 45 people with myopia (−2.84 ± 1.72 D). There were 23 people with low myopia (>−3 D) and 22 people with moderate myopia (−3 to −6 D). Right eye ciliary muscles were imaged (Visante OCT; Carl Zeiss Meditec) at 0 D and 6 D demands. Measures included ciliary muscle length (CML), ciliary muscle curved length (CMLarc), maximum ciliary muscle thickness (CMTmax), CMT1, CMT2, and CMT3 (fixed distances 1–3 mm from the scleral spur), CM25, CM50, and CM75 (proportional distances 25%–75%). Linear mixed model analysis determined effects of refractive groups, race, and demand on dimensions. Significance was set at P < 0.05. Results Myopic eyes had greater CML and CMLarc nasally than emmetropic eyes. Myopic eyes had thicker muscles than emmetropic eyes at nasal positions, except CM25 and CMT3, and at CM75 temporally. During accommodation and only nasally, CML reduced in emmetropic and myopic eyes, and CMLarc reduced in myopic eyes only. During accommodation, both nasally and temporally, muscles thickened anteriorly (CMT1 and CM25) and thinned posteriorly (CMT3 and CM75) except for temporal CM75. Moderate myopic eyes had greater temporal CMLarc than low myopic eyes, and the moderate myopes had thicker muscles both nasally and temporally using fixed and proportional distances. Conclusions People with myopia had longer and thicker ciliary muscles than people with emmetropia. During accommodation, the anterior muscle thickened and the curved nasal muscle length shortened, more in myopic than in emmetropic eyes. The fixed distance method is recommended for repeat measures in the same individual. The proportional distance method is recommended for comparisons between refractive groups.
Collapse
Affiliation(s)
- Dinesh Kaphle
- Centre for Vision and Eye Research, Queensland University of Technology, Kelvin Grove, Queensland, Australia.,Discipline of Optometry, Faculty of Health, University of Canberra, Bruce ACT 2617, Australia
| | - Katrina L Schmid
- Centre for Vision and Eye Research, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Leon N Davies
- School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | - Marwan Suheimat
- Centre for Vision and Eye Research, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - David A Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| |
Collapse
|
21
|
Abstract
The retinal and the choroidal thickness were measured at four locations along the horizontal direction (foveola, one nasal to the fovea and two temporal) in a group of 43 young adults (mean age: 27.1 ± 3.9 years), with ocular refraction ranging from emmetropia to high myopia (0 to −10D). Thickness values were obtained from OCT images centered at the foveal depression. The retinal thickness exhibited a correlation with refraction at all eccentricities but not at the fovea. When different subgroups of refraction were considered, the analysis of such correlations indicated that only the retinal thickness in the group of high myopia (refraction ≤ −6D) was statistically different from the other two groups (emmetropes: [−0.5, 0] D, and myopes: (−6, −0.5) D). No significant differences were found between emmetropic and myopic groups. In contrast to the retina, the choroidal thickness exhibited a significant correlation with refraction at the fovea, although such dependency only stood for high myopes (the choroid of myopes and emmetropes exhibited similar thickness). Correlation with refraction was also found at the nasal location, arising between emmetropic and high myopia groups. Other choroidal locations among groups did not exhibit relationship with the refraction. It is concluded that the differences in the choroid and retina thickness along the horizontal meridian as a function of refraction do not characterize the onset and progression of myopia at early stages, since they only manifest in the group of high myopia.
Collapse
|
22
|
Labiris G, Panagiotopoulou EK, Ntonti P. Development and Validation of a Lighting Facility for the Objective Assessment of the Visual Performance of Presbyopic Patients in a Series of Activities of Daily Living. Cureus 2022; 14:e24548. [PMID: 35651385 PMCID: PMC9138179 DOI: 10.7759/cureus.24548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/15/2022] [Indexed: 12/03/2022] Open
Abstract
Introduction The primary objective of this study is to develop and validate an experimental lighting facility that allows the evaluation of near and intermediate vision in different user-defined illuminance levels. Methods This is a prospective, randomized, controlled study. Normophakic patients populated three validation groups (VGs) according to their binocular uncorrected near visual acuity (UNVA): a) VG1, 0.0-0.1 logMAR; b) VG2, 0.4 logMAR; and c) VG3, 0.7 logMAR. All participants addressed 10 near and intermediate activities of daily life (ADLs) in the three following lighting settings: 1) 25 foot candles (fc)/3000 kelvins (K), 2) 50 fc/4000 K, and 3) 75 fc/6000 K. Results Thirty patients in each group performed all ADLs in the three lighting settings. VG1 demonstrated the best ADL scores in all ADLs and lighting settings, followed by the VG2. VG3 presented the worst scores. ADLs using printed material showed significant differences among the three lighting settings for all study groups, while ADLs using screens or needing manual dexterity demonstrated no significant differences except for the Screwdriver Test (ST) in VG1. All ADL scores demonstrated a high correlation with UNVA in all lighting settings (p < 0.001). Conclusion This is the first study that validates a lighting facility for comparative studies in patients with different near vision capacities performing a series of ADLs.
Collapse
Affiliation(s)
- Georgios Labiris
- Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, GRC
| | | | - Panagiota Ntonti
- Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, GRC
| |
Collapse
|
23
|
Wu T, Wang Y, Wei S, Guo Y, Li X. Developing dynamic defocus curve for evaluating dynamic vision accommodative function. BMC Ophthalmol 2022; 22:106. [PMID: 35248018 PMCID: PMC8898511 DOI: 10.1186/s12886-022-02335-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 03/03/2022] [Indexed: 11/16/2022] Open
Abstract
Background To assess dynamic visual acuity (DVA) under different defocus statuses and explore the assessment of dynamic vision accommodation. Methods Twenty subjects (6 males and 14 females) aged 18 to 35 were recruited. Nonmydriatic subjective refraction (sphere and cylinder) and accommodative tests including negative relative accommodation (NRA), positive relative accommodation (PRA), binocular cross cylinder (BCC) and accommodative facility using a flipper were performed. Binocular static visual acuity (SVA) and DVA at 40 degrees per second (dps) were measured under different defocus statuses (+1.5D to -4D in -0.5D steps) based on the refractive error fully corrected. Static and dynamic defocus curves were plotted. The area under the curve (AUC) and corrected dynamic vision accommodation (CDVAc) were calculated. Results The study showed that the dynamic defocus curve fitted the cubic curve properly (p<0.001). DVA was significantly worse than SVA at all defocused statuses (p<0.001), and the difference was more significant at greater defocus diopters. Single factor analysis indicated that CDVAc was significantly correlated with NRA-PRA (p=0.012) and AUCdynamic (p<0.001). Significant associations were observed between AUCdynamic and PRA (p=0.013) as well as NRA-PRA (p=0.021). Meanwhile, DVA was positively correlated with PRA at 0D, -1.0D, -1.5D, -2.5D and -3.0D (p<0.05) and with NRA-PRA at 0D, -1.0D, -1.5D, -2.0D and -2.5D (p<0.05). Multiple factor regression analysis indicated that CDVAc (0D ~ -3.5D) and SVA (+1.5D ~ +1.0D & -2.5D ~ -4.0D) were significant influential factors for defocused DVA (p<0.05). Conclusions Our study demonstrated that DVA had a defocus curve similar to that of SVA. CDVAc was feasible for the assessment of dynamic vision accommodative function. The dynamic defocus curve test could efficiently be applied in the evaluation of dynamic visual performance under different defocus statuses.
Collapse
|
24
|
Beesley J, Davey CJ, Elliott DB. What are the causes of non‐tolerance to new spectacles and how can they be avoided? Ophthalmic Physiol Opt 2022; 42:619-632. [PMID: 35156719 PMCID: PMC9303957 DOI: 10.1111/opo.12961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 01/17/2022] [Accepted: 01/17/2022] [Indexed: 11/26/2022]
Abstract
Purpose To investigate non‐tolerance cases from several UK practices to determine their likely causes and how they might have been avoided. Methods Patient complaint and refraction data were collected from non‐tolerance recheck examinations. For one practice, clinical data were also collected retrospectively to investigate the quality of the eye examinations. Results Data for 279 rechecks were gathered from 10 practices and a recheck frequency of 2.3% was found. The mean patient age was 60 (SD 16) years, with cylinder changes responsible for 38% of prescription‐related causes of rechecks, overplusing or underminusing 26%, and underplusing or overminusing just 11%. An assessment of 242 recheck corrections found that 40% were unsatisfactory (e.g., failed to address initial or recheck symptoms, N = 45) and retrospective analysis of 217 case records showed many limitations (e.g., 61% or 28% recorded no uncorrected or habitual visual acuity (VA) at either initial examination or recheck). Conclusions Given that overplus‐underminus was a much bigger proportion of prescription‐related cases than overminus‐underplus (26% vs. 11%), the refraction mantra of “maximum plus for maximum VA” should be balanced by increased teaching of the problems of overplusing and underminusing, and the use of prescribing guidelines. In addition, continuing professional development regarding the basics of the recheck examination, refraction, visual acuity and prism determination is needed. Changes of oblique cylinders should be carefully considered in older patients as this is a common cause of non‐tolerance. In addition, if the “if it ain't broke, don't fix it” and related maxims had been applied to all patients who were asymptomatic at the original examination, one third of all non‐tolerance cases could have been avoided. Finally, it would seem appropriate for practices to develop a system to deal better with non‐tolerance cases. Perhaps an experienced clinician should examine all patients with non‐tolerance and provide feedback to the original clinician.
Collapse
Affiliation(s)
- Jeremy Beesley
- Bradford School of Optometry and Vision Science University of Bradford Bradford UK
| | - Christopher J Davey
- Bradford School of Optometry and Vision Science University of Bradford Bradford UK
| | - David B Elliott
- Bradford School of Optometry and Vision Science University of Bradford Bradford UK
| |
Collapse
|
25
|
Aging of visual mechanisms. PROGRESS IN BRAIN RESEARCH 2022; 273:257-273. [DOI: 10.1016/bs.pbr.2022.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
26
|
Scaffold-Free Retinal Pigment Epithelium Microtissues Exhibit Increased Release of PEDF. Int J Mol Sci 2021; 22:ijms222111317. [PMID: 34768747 PMCID: PMC8583603 DOI: 10.3390/ijms222111317] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 12/26/2022] Open
Abstract
The retinal pigmented epithelium (RPE) plays a critical role in photoreceptor survival and function. RPE deficits are implicated in a wide range of diseases that result in vision loss, including age-related macular degeneration (AMD) and Stargardt disease, affecting millions worldwide. Subretinal delivery of RPE cells is considered a promising avenue for treatment, and encouraging results from animal trials have supported recent progression into the clinic. However, the limited survival and engraftment of transplanted RPE cells delivered as a suspension continues to be a major challenge. While RPE delivery as epithelial sheets exhibits improved outcomes, this comes at the price of increased complexity at both the production and transplant stages. In order to combine the benefits of both approaches, we have developed size-controlled, scaffold-free RPE microtissues (RPE-µTs) that are suitable for scalable production and delivery via injection. RPE-µTs retain key RPE molecular markers, and interestingly, in comparison to conventional monolayer cultures, they show significant increases in the transcription and secretion of pigment-epithelium-derived factor (PEDF), which is a key trophic factor known to enhance the survival and function of photoreceptors. Furthermore, these microtissues readily spread in vitro on a substrate analogous to Bruch’s membrane, suggesting that RPE-µTs may collapse into a sheet upon transplantation. We anticipate that this approach may provide an alternative cell delivery system to improve the survival and integration of RPE transplants, while also retaining the benefits of low complexity in production and delivery.
Collapse
|
27
|
Chang DH, Waring GO, Hom M, Barnett M. Presbyopia Treatments by Mechanism of Action: A New Classification System Based on a Review of the Literature. Clin Ophthalmol 2021; 15:3733-3745. [PMID: 34522079 PMCID: PMC8432361 DOI: 10.2147/opth.s318065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 07/08/2021] [Indexed: 01/07/2023] Open
Abstract
Presbyopia, a loss of accommodative ability associated with aging, is a significant cause of vision impairment globally. At the clinical level, it is a frustrating and difficult issue that negatively impacts patients’ quality of life. Less appreciated is the fact that loss of accommodative ability and its current treatments methods may present safety concerns, for example, increasing the risk of falls. Therefore, a more complete understanding of treatment options with respect to how they relate to the natural ability of the eye is needed to improve decision making and to aid clinicians in individualizing treatment options. This article reviews the options for expanding functional through focus—a term coined to describe the ability of the eye to see at all distances with minimal latency—by how they vary the refractive power over time, across the visual field, between eyes, or across a range of distances. ![]()
Point your SmartPhone at the code above. If you have a QR code reader the video abstract will appear. Or use: https://youtu.be/HZw7qvIu6pw
Collapse
Affiliation(s)
| | | | | | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| |
Collapse
|
28
|
Karkhanis MU, Ghosh C, Banerjee A, Hasan N, Likhite R, Ghosh T, Kim H, Mastrangelo CH. Correcting Presbyopia With Autofocusing Liquid-Lens Eyeglasses. IEEE Trans Biomed Eng 2021; 69:390-400. [PMID: 34232861 DOI: 10.1109/tbme.2021.3094964] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Presbyopia, an age-related ocular disorder, is characterized by the loss in the accommodative abilities of the human eye. Conventional methods of correcting presbyopia divide the field of view, thereby resulting in significant vision impairment. We demonstrate the design, assembly and evaluation of autofocusing eyeglasses for restoration of accommodation without dividing the field of view. METHODS The adaptive optics eyeglasses comprise of two variable-focus liquid lenses, a time-of-flight range sensor and low-power, dual microprocessor control electronics, housed within an ergonomic frame. Subject-specific accommodation deficiency models were utilized to demonstrate high-fidelity accommodative correction. The abilities of this system to reduce accommodation deficiency, its power consumption, response time, optical performance and MTF were evaluated. RESULTS Average corrected accommodation deficiencies for 5 subjects ranged from -0.021 D to 0.016 D. Each accommodation correction calculation was performed in ∼67 ms which consumed 4.86 mJ of energy. The optical resolution of the system was 10.5 cycles/degree, and featured a restorative accommodative range of 4.3 D. This system was capable of running for up to 19 hours between charge cycles and weighed ∼132 g. CONCLUSION The design, assembly and performance of an autofocusing eyeglasses system to restore accommodation in presbyopes has been demonstrated. SIGNIFICANCE The new autofocusing eyeglasses system presented in this article has the potential to restore pre-presbyopic levels of accommodation in subjects diagnosed with presbyopia.
Collapse
|
29
|
Sheppard AL, Bashir A, Wolffsohn JS, Davies LN. Accommodating intraocular lenses: a review of design concepts, usage and assessment methods. Clin Exp Optom 2021; 93:441-52. [DOI: 10.1111/j.1444-0938.2010.00532.x] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Affiliation(s)
| | - Abar Bashir
- Aston University, Birmingham, United Kingdom
E‐mail:
| | | | - Leon N Davies
- Aston University, Birmingham, United Kingdom
E‐mail:
| |
Collapse
|
30
|
Barcala X, Vinas M, Romero M, Gambra E, Mendez-Gonzalez JL, Marcos S, Dorronsoro C. Multifocal acceptance score to evaluate vision: MAS-2EV. Sci Rep 2021; 11:1397. [PMID: 33446794 PMCID: PMC7809428 DOI: 10.1038/s41598-021-81059-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 01/04/2021] [Indexed: 11/30/2022] Open
Abstract
We present a new metric (Multifocal Acceptance Score, MAS-2EV) to evaluate vision with presbyopic corrections. The MAS-2EV is based on a set of images representing natural visual scenes at day and night conditions projected in far and near displays, and a near stereo target. Subjects view and score the images through different binocular corrections (monofocal corrections at far; bifocal corrections; monovision and modified monovision) administered with soft contact lenses (in cyclopleged young subjects) or with a binocular simultaneous vision simulator (in presbyopic and cyclopleged young subjects). MAS-2EV scores are visually represented in the form of polygons, and quantified using different metrics: overall visual quality, visual degradation at far, visual benefit at near, near stereo benefit, visual imbalance near-far, overall visual imbalance and a combined overall performance metric. We have found that the MAS-2EV has sufficient repeatability and sensitivity to allow differentiation across corrections with only two repetitions, and the duration of the psychophysical task (3 min for subject/condition/correction) makes it useable in the clinic. We found that in most subjects binocular bifocal corrections produce the lowest visual imbalance, and the highest near stereo benefit. 46.67% of the subjects ranked binocular bifocal corrections first, and 46.67% of the subjects ranked monovision first. MAS-2EV, particularly in combination with visual simulators, can be applied to select prospective presbyopic corrections in patients prior to contact lens fitting or intraocular lens implantation.
Collapse
Affiliation(s)
| | - Maria Vinas
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Mercedes Romero
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | | | | | - Susana Marcos
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| |
Collapse
|
31
|
Turski J. A Geometric Theory Integrating Human Binocular Vision With Eye Movement. Front Neurosci 2020; 14:555965. [PMID: 33364918 PMCID: PMC7750472 DOI: 10.3389/fnins.2020.555965] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 09/18/2020] [Indexed: 11/25/2022] Open
Abstract
A theory of the binocular system with asymmetric eyes (AEs) is developed in the framework of bicentric perspective projections. The AE accounts for the eyeball's global asymmetry produced by the foveal displacement from the posterior pole, the main source of the eye's optical aberrations, and the crystalline lens' tilt countering some of these aberrations. In this theory, the horopter curves, which specify retinal correspondence of binocular single vision, are conic sections resembling empirical horopters. This advances the classic model of empirical horopters as conic sections introduced in an ad hoc way by Ogle in 1932. In contrast to Ogle's theory, here, anatomically supported horopteric conics vary with the AEs' position in the visual plane of bifoveal fixations and their transformations are visualized in a computer simulation. Integrating horopteric conics with eye movements can help design algorithms for maintaining a stable perceptual world from visual information captured by a mobile robot's camera head. Further, this paper proposes a neurophysiologically meaningful definition for the eyes' primary position, a concept which has remained elusive despite its theoretical importance to oculomotor research. Finally, because the horopteric conic's shape is dependent on the AE's parameters, this theory allows for changes in retinal correspondence, which is usually considered preformed and stable.
Collapse
|
32
|
|
33
|
Rodriguez-Lopez V, Dorronsoro C, Burge J. Contact lenses, the reverse Pulfrich effect, and anti-Pulfrich monovision corrections. Sci Rep 2020; 10:16086. [PMID: 32999323 PMCID: PMC7527565 DOI: 10.1038/s41598-020-71395-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 08/10/2020] [Indexed: 11/09/2022] Open
Abstract
Interocular differences in image blur can cause processing speed differences that lead to dramatic misperceptions of the distance and three-dimensional direction of moving objects. This recently discovered illusion-the reverse Pulfrich effect-is caused by optical conditions induced by monovision, a common correction for presbyopia. Fortunately, anti-Pulfrich monovision corrections, which darken the blurring lens, can eliminate the illusion for many viewing conditions. However, the reverse Pulfrich effect and the efficacy of anti-Pulfrich corrections have been demonstrated only with trial lenses. This situation should be addressed, for clinical and scientific reasons. First, it is important to replicate these effects with contact lenses, the most common method for delivering monovision. Second, trial lenses of different powers, unlike contacts, can cause large magnification differences between the eyes. To confidently attribute the reverse Pulfrich effect to interocular optical blur differences, and to ensure that previously reported effect sizes are reliable, one must control for magnification. Here, in a within-observer study with five separate experiments, we demonstrate that (1) contact lenses and trial lenses induce indistinguishable reverse Pulfrich effects, (2) anti-Pulfrich corrections are equally effective when induced by contact and trial lenses, and (3) magnification differences do not cause or impact the Pulfrich effect.
Collapse
Affiliation(s)
- Victor Rodriguez-Lopez
- Institute of Optics, Spanish National Research Council (IO-CSIC), Madrid, Spain
- Department of Psychology, University of Pennsylvania, Philadelphia, PA, USA
| | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council (IO-CSIC), Madrid, Spain
- 2Eyes Vision SL, Madrid, Spain
| | - Johannes Burge
- Department of Psychology, University of Pennsylvania, Philadelphia, PA, USA.
- Neuroscience Graduate Group, University of Pennsylvania, Philadelphia, PA, USA.
- Bioengineering Graduate Group, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
34
|
Wolffsohn JS, Leteneux-Pantais C, Chiva-Razavi S, Bentley S, Johnson C, Findley A, Tolley C, Arbuckle R, Kommineni J, Tyagi N. Social Media Listening to Understand the Lived Experience of Presbyopia: Systematic Search and Content Analysis Study. J Med Internet Res 2020; 22:e18306. [PMID: 32955443 PMCID: PMC7536603 DOI: 10.2196/18306] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 06/05/2020] [Accepted: 07/07/2020] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Presbyopia is defined as the age-related deterioration of near vision over time which is experienced in over 80% of people aged 40 years or older. Individuals with presbyopia have difficulty with tasks that rely on near vision. It is not currently possible to stop or reverse the aging process that causes presbyopia; generally, it is corrected with glasses, contact lenses, surgery, or the use of a magnifying glass. OBJECTIVE This study aimed to explore how individuals used social media to describe their experience of presbyopia with regard to the symptoms experienced and the impacts of presbyopia on their quality of life. METHODS Social media sources including Twitter, forums, blogs, and news outlets were searched using a predefined search string relating to symptoms and impacts of presbyopia. The data that were downloaded, based on the keywords, underwent manual review to identify relevant data points. Relevant posts were further manually analyzed through a process of data tagging, categorization, and clustering. Key themes relating to symptoms, impacts, treatment, and lived experiences were identified. RESULTS A total of 4456 social media posts related to presbyopia were identified between May 2017 and August 2017. Using a random sampling methodology, we selected 2229 (50.0%) posts for manual review, with 1470 (65.9%) of these 2229 posts identified as relevant to the study objectives. Twitter was the most commonly used channel for discussions on presbyopia compared to forums and blogs. The majority of relevant posts originated in Spain (559/1470, 38.0%) and the United States (426/1470, 29.0%). Of the relevant posts, 270/1470 (18.4%) were categorized as posts written by individuals who have presbyopia, of which 37 of the 270 posts (13.7%) discussed symptoms. On social media, individuals with presbyopia most frequently reported experiencing difficulty reading small print (24/37, 64.9%), difficulty focusing on near objects (15/37, 40.5%), eye strain (12/37, 32.4%), headaches (9/37, 24.3%), and blurred vision (8/37, 21.6%). 81 of the 270 posts (30.0%) discussed impacts of presbyopia-emotional burden (57/81, 70.4%), functional or daily living impacts (46/81, 56.8%), such as difficulty reading (46/81, 56.8%) and using electronic devices (21/81, 25.9%), and impacts on work (3/81, 3.7%). CONCLUSIONS Findings from this social media listening study provided insight into how people with presbyopia discuss their condition online and highlight the impact of presbyopia on individuals' quality of life. The social media listening methodology can be used to generate insights into the lived experience of a condition, but it is recommended that this research be combined with prospective qualitative research for added rigor and for confirmation of the relevance of the findings.
Collapse
Affiliation(s)
- James S Wolffsohn
- Optometry and Vision Science, College of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | | | | | - Sarah Bentley
- Patient-Centered Outcomes, Adelphi Values Ltd, Bollington, United Kingdom
| | - Chloe Johnson
- Patient-Centered Outcomes, Adelphi Values Ltd, Bollington, United Kingdom
| | - Amy Findley
- Patient-Centered Outcomes, Adelphi Values Ltd, Bollington, United Kingdom
| | - Chloe Tolley
- Patient-Centered Outcomes, Adelphi Values Ltd, Bollington, United Kingdom
| | - Rob Arbuckle
- Patient-Centered Outcomes, Adelphi Values Ltd, Bollington, United Kingdom
| | - Jyothi Kommineni
- Novartis Business Services, Product Lifecycle Services, Hyderabad, India
| | - Nishith Tyagi
- Novartis Business Services, Product Lifecycle Services, Hyderabad, India
| |
Collapse
|
35
|
Difference in Pupillary Diameter as an Important Factor for Evaluating Amplitude of Accommodation: A Prospective Observational Study. J Clin Med 2020; 9:jcm9082678. [PMID: 32824849 PMCID: PMC7465210 DOI: 10.3390/jcm9082678] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/11/2020] [Accepted: 08/15/2020] [Indexed: 12/29/2022] Open
Abstract
Presbyopia is increasing globally due to aging and the widespread use of visual display terminals. Presbyopia is a decrease in the eye's amplitude of accommodation (AA) due to loss of crystalline lens elasticity. AA differs widely among individuals. We aimed to determine the factors that cause presbyopia, other than advanced age, for early medical intervention. We examined 95 eyes of 95 healthy volunteers (33 men, 62 women) aged 22-62 years (mean: 37.22 ± 9.77 years) with a corrected visual acuity of ≥1.0 and without other eye afflictions except ametropia. Subjective refraction, AA, maximum and minimum pupillary diameters during accommodation, axial length of the eye, and crystalline lens thickness were measured. AA was measured using an auto refractometer/keratometer/tonometer/pachymeter. The difference between maximum and minimum pupillary diameters was calculated. On multiple regression analysis, age and difference in pupillary diameter were both significantly and independently associated with AA in participants aged <44 years, but not in those aged ≥45 years. Our results suggest that the difference in pupillary diameter could be an important age-independent factor for evaluating AA in healthy individuals without cataract. Thus, improving the difference in pupillary diameter values could be an early treatment target for presbyopia.
Collapse
|
36
|
Chen Z, Li T, Li M, Xu Y, Zhou X. Effect of Tropicamide on crystalline Lens rise in low-to-moderate myopic eyes. BMC Ophthalmol 2020; 20:327. [PMID: 32778077 PMCID: PMC7418382 DOI: 10.1186/s12886-020-01594-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 07/31/2020] [Indexed: 12/17/2022] Open
Abstract
Background Cycloplegics have been reported to induce changes in the lens thickness. However, the studies of correlation between cycloplegia and the lens position are limited. This study aims to investigate changes in crystalline lens rise (CLR) and other anterior segment parameters after inducing cycloplegia with tropicamide. Methods In this consecutive case study, 39 children (20 boys and 19 girls; mean age, 9.51 ± 1.75 years, mean spherical equivalence [SE], − 1.9 ± 1.5 D) with low-to moderate myopia were examined using CASIA 2 both before and after 30 min of administering 5-cycles (each 5 min apart) of 0.5% tropicamide. Measurements included CLR, crystalline lens thickness (CLT), mean radius of curvature of the anterior/posterior surface of the lens (Rf_ave/Rb_ave), anterior chamber depth (ACD), anterior chamber width (ACW), and central corneal thickness (CCT). Correlations of CLT and CLR with ACD, SE, and age were assessed respectively. Results CLT and CLR decreased significantly after cycloplegia (p < 0.001 and p < 0.001, respectively); whereas CCT, ACD, and Rf_ave increased (p = 0.008, p < 0.001, p < 0.001, respectively). A positive correlation was found between CLR and SE (r = 0.565, p < 0.001). However, a negative correlation between ACD and CLR was found before and after cycloplegia (r = − 0.430, p = 0.006; r = − 0.342, p = 0.035, respectively). Conclusions The crystalline lens appeared thinner and moved backward after cycloplegia. ACD increased mainly due to the backward movement of the crystalline lens. These results aid in elucidating the impact of crystalline lens changes during the process of accommodation.
Collapse
Affiliation(s)
- Zhuoyi Chen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Tao Li
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Meiyan Li
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Ye Xu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China. .,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. .,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
| |
Collapse
|
37
|
Mitsukawa T, Suzuki Y, Momota Y, Suzuki S, Yamada M. Anterior Segment Biometry During Accommodation and Effects of Cycloplegics by Swept-Source Optical Coherence Tomography. Clin Ophthalmol 2020; 14:1237-1243. [PMID: 32440090 PMCID: PMC7213076 DOI: 10.2147/opth.s252474] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 04/21/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose We analyzed changes in the crystalline lens during accommodation and the effects of cycloplegics by swept-source anterior-segment optical coherence tomography (AS-OCT). Materials and Methods Twenty healthy volunteers (7 males and 13 females, aged 22–34 years), with no history of eye disease except for refractive errors, were recruited. Biometric parameters, including anterior chamber depth (ACD), lens thickness (LT), and anterior and posterior curvature of the lens (ACL and PCL), were measured using AS-OCT (CASIA2). The measurements were performed with or without an accommodative demand of 5.0 diopters (D). The same tests were repeated following the topical administration of 1% cyclopentolate or a compounding agent comprising 0.5% tropicamide and 0.5% phenylephrine. Results The AS-OCT system was capable of simultaneous visualization of all optical components of the anterior segment in a single frame. ACD, LAC, and LPC decreased and LT increased significantly during 5.0 D accommodative stimulation in both eyes. Both cyclopentolate and tropicamide/phenylephrine eyedrops led to deeper ACD, thinner LT, and flatter LAC. There were no significant differences in all lens parameters despite having 5.0 D accommodative stimulation in both eyes with cycloplegia. Conclusion Our results suggest that both tropicamide/phenylephrine and cyclopentolate eyedrops have enough cycloplegic effects in young adults.
Collapse
Affiliation(s)
- Tadahiro Mitsukawa
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Yumi Suzuki
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Yosuke Momota
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Shun Suzuki
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| | - Masakazu Yamada
- Department of Ophthalmology, Kyorin University School of Medicine, Mitaka, Tokyo 181-8611, Japan
| |
Collapse
|
38
|
Kim JJ, Liu H, Ousati Ashtiani A, Jiang H. Biologically inspired artificial eyes and photonics. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2020; 83:047101. [PMID: 31923911 PMCID: PMC7195211 DOI: 10.1088/1361-6633/ab6a42] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Natural visual systems have inspired scientists and engineers to mimic their intriguing features for the development of advanced photonic devices that can provide better solutions than conventional ones. Among various kinds of natural eyes, researchers have had intensive interest in mammal eyes and compound eyes due to their advantages in optical properties such as focal length tunability, high-resolution imaging, light intensity modulation, wide field of view, high light sensitivity, and efficient light management. A variety of different approaches in the broad field of science and technology have been tried and succeeded to duplicate the functions of natural eyes and develop bioinspired photonic devices for various applications. In this review, we present a comprehensive overview of bioinspired artificial eyes and photonic devices that mimic functions of natural eyes. After we briefly introduce visual systems in nature, we discuss optical components inspired by the mammal eyes, including tunable lenses actuated with different mechanisms, curved image sensors with low aberration, and light intensity modulators. Next, compound eye inspired photonic devices are presented, such as microlenses and micromirror arrays, imaging sensor arrays on curved surfaces, self-written waveguides with microlens arrays, and antireflective nanostructures (ARS). Subsequently, compound eyes with focal length tunability, photosensitivity enhancers, and polarization imaging sensors are described.
Collapse
Affiliation(s)
- Jae-Jun Kim
- Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706, United States of America
| | | | | | | |
Collapse
|
39
|
Park HM, Ryu YU, Park IJ, Chu BS. Can Tinted Lenses Be Used to Manipulate Pupil Size and Visual Performance When Wearing Multifocal Contact Lenses? CLINICAL OPTOMETRY 2020; 12:27-35. [PMID: 32184694 PMCID: PMC7062197 DOI: 10.2147/opto.s245715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Accepted: 02/21/2020] [Indexed: 06/10/2023]
Abstract
BACKGROUND The purpose of this study is to investigate the effect of wearing neutral density (ND) filters with different transmittance levels over multifocal contact lenses (MTF CLs) on pupil size, visual functions and the dynamic accommodative response under daylight conditions in early presbyopes. METHODS Seventeen individuals aged between 40 and 48 years (mean age 42.35±2.62 years) were recruited to participate in this study. This study involved a repeated-measures design with two within-subject factors: optical condition (which had five levels), and fixation distance (which had three levels). The five optical conditions were no correction (baseline), MTF CL wear, MTF CL wear + 0.3 ND filter (transmission [Tv]=48.38%), MTF CL wear + 0.6 ND filter (Tv=27.12%) and MTF CL wear + 0.9 ND filter (Tv=14.58%). The three fixation distances were 3 m, 40 cm and 20 cm. Outcome measures were pupil size, the measured accommodative response (optical aid + physiological accommodation), distance visual acuity (VA), near VA and contrast sensitivity (CS). RESULTS There was no effect of optical condition on the accommodative response; however, there was a significant effect of fixation distance. (Accommodative response was 0.44±0.29, 1.83±0.37 and 4.03±0.46 D for fixation distances of 3 m, 40 cm and 20 cm, respectively; p<0.05.) There was a significant effect of optical condition (p<0.05) and of fixation distance on pupil size variation (5.13±0.90 mm for 3 m, 4.71±0.92 mm for 40 cm and 4.11±1.04 mm for 20 cm; p<0.05). Optical condition had a significant effect on distance VA, near VA and CS (p<0.05). Compared to the reduction in distance VA, near VA was relatively small (two-letter reduction with 0.9 ND) and unlikely to be clinically significant. CONCLUSION This study demonstrated that in a group of adults with early presbyopia, the use of ND filters enlarged pupil size. However, the combination of enlarged pupils and MTF CL did not improve distance vision, and if transmittance was reduced by 50% it resulted in decrements in vision and CS. MTF CL designs which incorporate tints, or tints that vary in darkness in response to ultraviolet exposure, should consider these findings.
Collapse
Affiliation(s)
- Hyung Min Park
- School of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea
| | - Young Uk Ryu
- Department of Physical Therapy, Daegu Catholic University, Gyeongsan-si, Republic of Korea
| | - Inn-Jee Park
- School of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea
| | - Byoung Sun Chu
- School of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea
| |
Collapse
|
40
|
Atropine 0.01% for the Control of Myopia in Chinese Children: Effect on Accommodation Functions and Pupil Size. J Ophthalmol 2020. [DOI: 10.1155/2020/7525180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background. To explore the effect of atropine 0.01% on accommodation functions and pupil size for safely and effectively controlling myopia in Chinese children. Methods. This was a single-center randomized clinical trial. 63 participants with myopia of at least −0.50 D and astigmatism of ≤−2.50 D were enrolled and randomized to receive atropine 0.01% once nightly with regular single-vision lenses or to wear regular single-vision lenses, in an allocation ratio of 3 : 2. Primary outcomes included changes of accommodation functions, pupil diameter, distant and near best-corrected visual acuity (BCVA), near stereoacuity, and intraocular pressure (IOP). Secondary outcome was myopic progression at 6 months. Results. 61 participants completed the follow-up. Compared with the control group, the atropine-treated children showed a statistically significant increase in pupil diameter after 6 months (0.7 ± 0.7 vs. 0.1 ± 0.5 mm, P=0.01). Despite the enlarged pupil, routine vision-related activities were not affected. The mean changes in accommodative functions, BCVA, near stereoacuity, and IOP, did not differ significantly between the groups. At 6 months, participants in the control group showed greater myopia progression than those in the atropine group (spherical equivalent: −0.60 ± 0.43 vs.−0.30 ± 0.42 D, P<0.001; axial length: 0.35 ± 0.20 vs. 0.24 ± 0.16 mm, P=0.001). Conclusions. Atropine 0.01% eye drops significantly increased pupil diameter less than one mm, but it did not affect accommodative functions, BCVA, near stereoacuity, and IOP. Combined with its reducing myopia progression, atropine 0.01% can be used as a safe and effective treatment for myopia in Chinese children.
Collapse
|
41
|
Monocular accommodation response to random defocus changes induced by a tuneable lens. Vision Res 2019; 165:45-53. [PMID: 31634733 DOI: 10.1016/j.visres.2019.10.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 09/20/2019] [Accepted: 10/01/2019] [Indexed: 11/23/2022]
Abstract
Accommodation of the human eye relies on multiple factors and visual cues that include object size, monochromatic and chromatic aberrations, and vergence. Yet, even in monocular conditions, accommodation corrects for defocus. Studies of eye growth in chicks have addressed whether the retina can decode the sign of defocus as this may play a role for emmetropization and possibly also accommodation. However, findings have not been unambiguous and questions remain. Here, we report on monocular accommodation studies of emmetropic and myopic human subjects to clarify whether foveal vision drives accommodation in the correct direction by removing out-of-focus blur potentially before relying on other cues. Subjects viewed monocularly a green target at 1-meter distance while being presented with a random sequence of negative defocus step changes induced by a pupil-conjugated current-driven tuneable lens. The natural pupil was constricted by a pupil-conjugated motorized iris using three different diameters and target brightness was set with a liquid crystal variable attenuator. A Hartmann-Shack wavefront sensor with an infrared beacon captured real-time changes of defocus and Zernike polynomial coefficients up to 4th radial order. We find that the young adult eye accommodates reliably in the correct direction but with a latency of 300-700 ms. The findings are discussed in relation to an absorption model of light in outer segments that breaks the defocus symmetry and thus may serve as a plausible guide for accommodation and emmetropization.
Collapse
|
42
|
Mansoor N, Wahid F, Azam M, Shah K, den Hollander AI, Qamar R, Ayub H. Molecular Mechanisms of Complement System Proteins and Matrix Metalloproteinases in the Pathogenesis of Age-Related Macular Degeneration. Curr Mol Med 2019; 19:705-718. [PMID: 31456517 DOI: 10.2174/1566524019666190828150625] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 08/06/2019] [Accepted: 08/09/2019] [Indexed: 02/08/2023]
Abstract
Age-related macular degeneration (AMD) is an eye disorder affecting predominantly the older people above the age of 50 years in which the macular region of the retina deteriorates, resulting in the loss of central vision. The key factors associated with the pathogenesis of AMD are age, smoking, dietary, and genetic risk factors. There are few associated and plausible genes involved in AMD pathogenesis. Common genetic variants (with a minor allele frequency of >5% in the population) near the complement genes explain 40-60% of the heritability of AMD. The complement system is a group of proteins that work together to destroy foreign invaders, trigger inflammation, and remove debris from cells and tissues. Genetic changes in and around several complement system genes, including the CFH, contribute to the formation of drusen and progression of AMD. Similarly, Matrix metalloproteinases (MMPs) that are normally involved in tissue remodeling also play a critical role in the pathogenesis of AMD. MMPs are involved in the degradation of cell debris and lipid deposits beneath retina but with age their functions get affected and result in the drusen formation, succeeding to macular degeneration. In this review, AMD pathology, existing knowledge about the normal and pathological role of complement system proteins and MMPs in the eye is reviewed. The scattered data of complement system proteins, MMPs, drusenogenesis, and lipofusogenesis have been gathered and discussed in detail. This might add new dimensions to the understanding of molecular mechanisms of AMD pathophysiology and might help in finding new therapeutic options for AMD.
Collapse
Affiliation(s)
- Naima Mansoor
- Department of Biotechnology, COMSATS University Islamabad, Abbottabad Campus, 22060, Pakistan
| | - Fazli Wahid
- Department of Biotechnology, COMSATS University Islamabad, Abbottabad Campus, 22060, Pakistan
| | - Maleeha Azam
- Department of Biosciences, COMSATS University Islamabad, Pakistan
| | - Khadim Shah
- Department of Biotechnology, COMSATS University Islamabad, Abbottabad Campus, 22060, Pakistan
| | - Anneke I den Hollander
- Department of Ophthalmology, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands
| | - Raheel Qamar
- Department of Biosciences, COMSATS University Islamabad, Pakistan
| | - Humaira Ayub
- Department of Biotechnology, COMSATS University Islamabad, Abbottabad Campus, 22060, Pakistan
| |
Collapse
|
43
|
Sanz Diez P, Ohlendorf A, Schaeffel F, Wahl S. Effect of spatial filtering on accommodation. Vision Res 2019; 164:62-68. [PMID: 31356834 DOI: 10.1016/j.visres.2019.07.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 07/12/2019] [Accepted: 07/22/2019] [Indexed: 11/26/2022]
Abstract
The purpose of this study was to develop and test a new method that uses natural images to investigate the influence of their spatial frequency content on the accommodation response (AR). Furthermore, the minimum spatial frequency content was determined that was necessary to induce an AR. Blur of the images was manipulated digitally in the Fourier domain by filtering with a Sinc function. Fourteen young subjects participated in the experiment. A 2-step procedure was used: (1) verifying that a high amount of Sinc-blur does not evoke accommodation, (2) increasing the width of the Sinc-blur filter in logarithmic steps until an AR was evoked. AR was continuously monitored using eccentric infrared photorefraction at 60 Hz sampling rate under monocular viewing conditions. Under condition (1), Sinc-blur of λ = 1 cpd did not evoke accommodation, while under condition (2) an average (mean ± standard deviation) Sinc-blur of λ = 5.57 ± 4.67 cpd (median: 4 cpd, interquartile range: 2-7 cpd) evoked accommodation. Dividing the subjects into myopes and emmetropes revealed that the myopic group required higher amounts of λ (higher spatial frequencies) to stimulate their accommodation (mean λ = 9.33 ± 4.99 cpd, for myopes; and mean λ = 2.75 ± 0.97 cpd, for emmetropes). Our results support the notion that the AR is most effectively stimulated at mid-spatial frequencies and that myopes may require higher spatial frequencies to elicit a comparable AR.
Collapse
Affiliation(s)
- Pablo Sanz Diez
- Carl Zeiss Vision International GmbH, Turnstrasse 27, 73430 Aalen, Germany; Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Elfriede-Aulhorn-Straße 7, 72076 Tuebingen, Germany.
| | - Arne Ohlendorf
- Carl Zeiss Vision International GmbH, Turnstrasse 27, 73430 Aalen, Germany; Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Elfriede-Aulhorn-Straße 7, 72076 Tuebingen, Germany
| | - Frank Schaeffel
- Section of Neurobiology of the Eye, Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Elfriede-Aulhorn-Straße 7, 72076 Tuebingen, Germany
| | - Siegfried Wahl
- Carl Zeiss Vision International GmbH, Turnstrasse 27, 73430 Aalen, Germany; Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Elfriede-Aulhorn-Straße 7, 72076 Tuebingen, Germany
| |
Collapse
|
44
|
Burge J, Rodriguez-Lopez V, Dorronsoro C. Monovision and the Misperception of Motion. Curr Biol 2019; 29:2586-2592.e4. [PMID: 31353183 DOI: 10.1016/j.cub.2019.06.070] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 06/24/2019] [Accepted: 06/24/2019] [Indexed: 11/27/2022]
Abstract
Monovision is a common prescription lens correction for presbyopia [1]. Each eye is corrected for a different distance, causing one image to be blurrier than the other. Millions of people have monovision corrections, but little is known about how interocular blur differences affect motion perception. Here, we report that blur differences cause a previously unknown motion illusion that makes people dramatically misperceive the distance and three-dimensional direction of moving objects. The effect occurs because the blurry and sharp images are processed at different speeds. For moving objects, the mismatch in processing speed causes a neural disparity, which results in the misperceptions. A variant of a 100-year-old stereo-motion phenomenon called the Pulfrich effect [2], the illusion poses an apparent paradox: blur reduces contrast, and contrast reductions are known to cause neural processing delays [3-6], but our results indicate that blurry images are processed milliseconds more quickly. We resolve the paradox with known properties of the early visual system, show that the misperceptions can be severe enough to impact public safety, and demonstrate that the misperceptions can be eliminated with novel combinations of non-invasive ophthalmic interventions. The fact that substantial perceptual errors are caused by millisecond differences in processing speed highlights the exquisite temporal calibration required for accurate perceptual estimation. The motion illusion-the reverse Pulfrich effect-and the paradigm we use to measure it should help reveal how optical and image properties impact temporal processing, an important but understudied issue in vision and visual neuroscience.
Collapse
Affiliation(s)
- Johannes Burge
- Department of Psychology, University of Pennsylvania, Goddard 426, 3710 Hamilton Walk, Philadelphia, PA 19104, USA; Neuroscience Graduate Group, University of Pennsylvania, Goddard 426, 3710 Hamilton Walk, Philadelphia, PA 19104, USA; Bioengineering Graduate Group, University of Pennsylvania, Goddard 426, 3710 Hamilton Walk, Philadelphia, PA 19104, USA.
| | - Victor Rodriguez-Lopez
- Department of Psychology, University of Pennsylvania, Goddard 426, 3710 Hamilton Walk, Philadelphia, PA 19104, USA; Institute of Optics, Spanish National Research Council, IO-CSIC, Calle Serrano 121, 28006 Madrid, Spain
| | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Calle Serrano 121, 28006 Madrid, Spain
| |
Collapse
|
45
|
Condino S, Carbone M, Piazza R, Ferrari M, Ferrari V. Perceptual Limits of Optical See-Through Visors for Augmented Reality Guidance of Manual Tasks. IEEE Trans Biomed Eng 2019; 67:411-419. [PMID: 31059421 DOI: 10.1109/tbme.2019.2914517] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE The focal length of available optical see-through (OST) head-mounted displays (HMDs) is at least 2 m; therefore, during manual tasks, the user eye cannot keep in focus both the virtual and real content at the same time. Another perceptual limitation is related to the vergence-accommodation conflict, the latter being present in binocular vision only. This paper investigates the effect of incorrect focus cues on the user performance, visual comfort, and workload during the execution of augmented reality (AR)-guided manual task with one of the most advanced OST HMD, the Microsoft HoloLens. METHODS An experimental study was designed to investigate the performance of 20 subjects in a connect-the-dots task, with and without the use of AR. The following tests were planned: AR-guided monocular and binocular, and naked-eye monocular and binocular. Each trial was analyzed to evaluate the accuracy in connecting dots. NASA Task Load Index and Likert questionnaires were used to assess the workload and the visual comfort. RESULTS No statistically significant differences were found in the workload, and in the perceived comfort between the AR-guided binocular and monocular test. User performances were significantly better during the naked eye tests. No statistically significant differences in performances were found in the monocular and binocular tests. The maximum error in AR tests was 5.9 mm. CONCLUSION Even if there is a growing interest in using commercial OST HMD, for guiding high-precision manual tasks, attention should be paid to the limitations of the available technology not designed for the peripersonal space.
Collapse
|
46
|
Jarosz J, Molliex N, Chenon G, Berge B. Adaptive eyeglasses for presbyopia correction: an original variable-focus technology. OPTICS EXPRESS 2019; 27:10533-10552. [PMID: 31052911 DOI: 10.1364/oe.27.010533] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Accepted: 03/14/2019] [Indexed: 06/09/2023]
Abstract
We propose an original variable-focus technology specially designed for presbyopia-correcting adaptive eyeglasses. It has been thought through to offer vision comfort without cutting on aesthetics. It relies on a fluid-filled variable-focus lens (presenting 2 liquids and 1 ultra-thin membrane) assisted by a low-power, high-volume microfluidic actuator. It also features a distance-sensing system to provide automatic focusing. We demonstrate the qualities of this novel technology on our first prototype. Our prototype achieves the necessary 3-diopter-high power variation on a 20-millimeter-wide variable zone with low actuation pressures (~200 Pa at most), and the preliminary optical quality analysis shows the spatial resolution is much better than the one specified by classic eye charts. We discuss further improvements in terms of optics, aesthetics and portability. In particular, we point out that this variable technology is compatible with standard base curves, and we highlight an optimal configuration where the power consumption of our opto-fluidic engine is about 25 mW peak.
Collapse
|
47
|
Anterior Segment Biometry with Phenylephrine and Tropicamide during Accommodation Imaged with Ultralong Scan Depth Optical Coherence Tomography. J Ophthalmol 2019; 2019:6827215. [PMID: 30944731 PMCID: PMC6421770 DOI: 10.1155/2019/6827215] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Revised: 02/01/2019] [Accepted: 02/05/2019] [Indexed: 11/30/2022] Open
Abstract
Purpose To investigate the influence of phenylephrine and tropicamide on anterior segment biometry with ultralong scan depth optical coherence tomography (UL-OCT) during accommodation. Methods In this study, 20 left eyes of healthy volunteers with a mean ± standard deviation age of 31.05 ± 5.84 years and a mean refraction of −1.16 ± 1.11 diopters (range 0∼−3.0 D) were imaged using UL-OCT after instillation of artificial tears, phenylephrine, and tropicamide in three follow-up trials, respectively. At each follow-up trial, two repeated measurements were performed at states of relax and 5D accommodative stimulation. The dimensional parameters included central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter (PD), lens thickness (LT), and horizontal radii of the lens anterior and posterior surface curvatures (LAC and LPC). Results Tropicamide led to larger pupil, deeper ACD, thinner LT, and flatter crystalline lens surface (P < 0.05). Phenylephrine induced an increase in PD (P < 0.05), while no significant changes were seen in ACD, LT, LAC, and LPC (P > 0.05). CCT did not change after both phenylephrine and tropicamide instillation in this study (P > 0.05). Tropicamide induced the loss of accommodation and phenylephrine achieved pupil dilation without affecting the accommodation. PD, ACD decreased, LT increased significantly and the anterior and posterior surface of the lens in a 6.294 mm of diameter optical zone became steeper during accommodation after administration of phenylephrine (P < 0.05). Conclusion The anterior segment physiology changed after tropicamide instillation. Besides, tropicamide induced the loss of accommodation and phenylephrine preserved the accommodation with a larger pupil. And, the anterior and posterior surface of lens in a 6.294 mm of diameter optical zone became steeper during the accommodation.
Collapse
|
48
|
Wang K, Hoshino M, Uesugi K, Yagi N, Pierscionek BK. Contributions of shape and stiffness to accommodative loss in the ageing human lens: a finite element model assessment. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2019; 36:B116-B122. [PMID: 31044989 DOI: 10.1364/josaa.36.00b116] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Accepted: 03/06/2019] [Indexed: 06/09/2023]
Abstract
Ageing changes to the various components of the accommodative system of the eye lens contribute to the loss of focusing power. The relative contributions of each ageing component, however, are not well defined. This study investigates the contribution of geometric parameters and material properties on accommodation, simulated using models based on human lenses aged 16, 35, and 48 years. Each model was tested using two different sets of material properties and a range of zonular fiber angles and was compared to results from in vivo measurements. The geometries and material parameters of older and younger lens models were interchanged to investigate the role of shape and material on accommodative capacity. Results indicate that geometry has the greater role in accommodation.
Collapse
|
49
|
Sánchez-González MC, Pérez-Cabezas V, Gutiérrez-Sánchez E, Ruiz-Molinero C, Rebollo-Salas M, Jiménez-Rejano JJ. Nonstrabismic binocular dysfunctions and cervical complaints: The possibility of a cross-dysfunction. PLoS One 2019; 14:e0209710. [PMID: 30645581 PMCID: PMC6333362 DOI: 10.1371/journal.pone.0209710] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 12/09/2018] [Indexed: 11/29/2022] Open
Abstract
The aim of this study is to establish a relationship between non-strabismic binocular dysfunction and neck pain. One hundred twelve participants underwent binocular vision assessment by evaluating horizontal heterophoria, horizontal and vertical fusional vergence ranges and vergence facility. The subjects were classified into two groups: binocular anomalies and normal binocular function. Neck complaints were measured with the Neck Disability Index, visual analogue scale, cervical range of motion, deep-flexor muscle activation score (AS) and performance index (PI). Our results showed that participants with low AS had significantly altered values of lateral phoria (near) (mean = -6.99 SD ± 6.96 PD) and PFV (near) blur (mean = 9.49 SD ± 5.45 PD) against those who presented normal AS (lateral phoria (near) mean = -3.64 SD ± 6.37 PD; PFV (near) blur mean = 12.84 SD ± 6.20 PD). In addition, participants with NFV (near) recovery outside the norm had a significantly lower right side-bending (mean = 35.63 SD ± 8.35 PD) than those within the standard (mean = 39.64 SD ± 9 PD). The subjects with binocular vision impairment showed a diminished response to the deep cervical musculature, with low AS and PI, as well as a tendency to suffer from cervicalgia of more than three months’ evolution and a lower range of motion.
Collapse
Affiliation(s)
| | | | | | - Carmen Ruiz-Molinero
- Department of Nursing and Physiotherapy, University of Cadiz, Cadiz, Spain
- * E-mail:
| | | | | |
Collapse
|
50
|
Zetterlund C, Lundqvist LO, Richter HO. Visual, musculoskeletal and balance symptoms in individuals with visual impairment. Clin Exp Optom 2018; 102:63-69. [PMID: 29938826 DOI: 10.1111/cxo.12806] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Revised: 05/28/2018] [Accepted: 05/30/2018] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND Visual impairment is globally among the most prevalent disabilities. Research concerning the health consequences of visual deficits is challenged by confounding effects of age, because visual impairment becomes more prevalent with age. This study investigates the influence of visual deficits on visual, musculoskeletal and balance symptoms in adults with and without visual impairment, while controlling for age effects. METHODS Thirty-nine patients with visual impairment, aged 18-72 years, were compared to 37 age-matched controls with normal vision, allocated to two age groups: < 45 and ≥ 45 years. Self-reported symptoms were measured using the Visual, Musculoskeletal and Balance Symptoms Questionnaire and compared with demographic and optometric variables. RESULTS In total, patients with visual impairment reported more symptoms than age-matched normally sighted controls. Younger adults in the control group were almost free from symptoms, whereas younger adults with visual impairment reported levels of symptoms equal to older adults with visual impairment. Multiple logistic regression modelling identified use of eyeglasses, magnifying aids and presence of anisometropia to be the most influential risk factors for reporting visual, musculoskeletal and balance symptoms, with accentuated influence on balance symptoms. CONCLUSIONS People with visual impairments and people with age-related normal visual deficits are both predisposed to report visual, musculoskeletal and balance symptoms relative to people without visual defects or need for eye-wear correction. Age-related variations in symptoms were observed in the control groups but not in the visual impairment groups, with younger visual impairment patients reporting as many symptoms as older visual impairment patients. These findings indicate a need for a wider interdisciplinary perspective on eye care concerning people with visual impairment and people with need for habitual daily use of eye wear correction.
Collapse
Affiliation(s)
- Christina Zetterlund
- Low Vision Centre, Region Örebro County, Örebro, Sweden.,University Health Care Research Center, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - Lars-Olov Lundqvist
- University Health Care Research Center, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - Hans Olof Richter
- Centre for Musculoskeletal Research, Department of Occupational and Public Health Science, University of Gävle, Gävle, Sweden
| |
Collapse
|