Amodeo A, Ündar A. Welcome to the Thirteen International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion. Artif Organs 2017. [DOI: 10.1111/aor.13014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
2
|
Adedayo P, Wang S, Kunselman AR, Ündar A. Impact of Pulsatile Flow Settings on Hemodynamic Energy Levels Using the Novel Diagonal Medos DP3 Pump in a Simulated Pediatric Extracorporeal Life Support System. World J Pediatr Congenit Heart Surg 2014; 5:440-8. [DOI: 10.1177/2150135114526760] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Accepted: 02/10/2014] [Indexed: 11/15/2022]
Abstract
Background: The objective of this study was to evaluate the pump performance of the novel diagonal Medos Deltastream DP3 diagonal pump (MEDOS Medizintechnik AG, , Stolberg, Germany) under nonpulsatile to pulsatile mode with varying differential speed values in a simulated pediatric extracorporeal life support system. Methods: The experimental circuit consisted of a Medos Deltastream DP3 pump head and console, a Medos Hilite 2400 LT hollow fiber membrane oxygenator (MEDOS Medizintechnik AG), a 14F Medtronic DLP arterial cannula (Medtronic Inc, Minnesota), and a 20F Terumo TenderFlow Pediatric venous return cannula (Terumo Corporation, Michigan). Trials were conducted at flow rates ranging from 500 mL/min to 2,000 mL/min (500 mL/min increments) and pulsatile differential speed values ranging from 500 rpm to 2,500 rpm (500 rpm increments) using human blood (hematocrit 35%). The postcannula pressure was maintained constantly at 60 mm Hg. Real-time pressure and flow data were recorded using a custom-made data acquisition system and Labview software. Results: Under all experimental conditions, pulsatile flow (P) generated significantly greater energy equivalent pressure (EEP), surplus hemodynamic energy (SHE), and total hemodynamic energy (THE) than those of nonpulsatile flow (NP). Under NP, SHE was zero. Higher differential speed values generated greater EEP, SHE, and THE values. There was little variation in the oxygenator pressure drop and the cannula pressure drop in P, compared to NP. Conclusions: The novel Medos Deltastream DP3 diagonal pump is able to generate physiological quality of P, without backflow. With increased differential rpm, the pump generated greater EEP, SHE, and THE. Physiological quality of pulsatility may be associated with better microcirculation because of greater EEP, SHE, and THE.
Collapse
Affiliation(s)
- Pelumi Adedayo
- Department of Pediatrics, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children’s Hospital, Hershey, PA, USA
| | - Shigang Wang
- Department of Pediatrics, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children’s Hospital, Hershey, PA, USA
| | - Allen R. Kunselman
- Department of Public Health and Sciences, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children’s Hospital, Hershey, PA, USA
| | - Akif Ündar
- Department of Pediatrics, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children’s Hospital, Hershey, PA, USA
- Department of Surgery and Bioengineering, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children’s Hospital, Hershey, PA, USA
| |
Collapse
|
3
|
Wang S, Evenson A, Chin BJ, Kunselman AR, Ündar A. Evaluation of Conventional Nonpulsatile and Novel Pulsatile Extracorporeal Life Support Systems in a Simulated Pediatric Extracorporeal Life Support Model. Artif Organs 2014; 39:E1-9. [DOI: 10.1111/aor.12290] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- Shigang Wang
- Pediatric Cardiovascular Research Center; Penn State Hershey Children's Hospital; Penn State Milton S. Hershey Medical Center; Department of Pediatrics; Penn State Hershey College of Medicine; Hershey PA USA
| | - Alissa Evenson
- Pediatric Cardiovascular Research Center; Penn State Hershey Children's Hospital; Penn State Milton S. Hershey Medical Center; Department of Pediatrics; Penn State Hershey College of Medicine; Hershey PA USA
| | - Brian J. Chin
- Pediatric Cardiovascular Research Center; Penn State Hershey Children's Hospital; Penn State Milton S. Hershey Medical Center; Department of Pediatrics; Penn State Hershey College of Medicine; Hershey PA USA
| | - Allen R. Kunselman
- Department of Public Health Sciences; Penn State Hershey College of Medicine; Hershey PA USA
| | - Akif Ündar
- Pediatric Cardiovascular Research Center; Penn State Hershey Children's Hospital; Penn State Milton S. Hershey Medical Center; Department of Pediatrics; Penn State Hershey College of Medicine; Hershey PA USA
- Department of Surgery; Penn State Milton S. Hershey Medical Center; Penn State Hershey College of Medicine; Hershey PA USA
- Department of Bioengineering; College of Engineering; Pennsylvania State University; University Park PA USA
| |
Collapse
|
4
|
Wang S, Kunselman AR, Ündar A. In Vitro Performance Analysis of a Novel Pulsatile Diagonal Pump in a Simulated Pediatric Mechanical Circulatory Support System. Artif Organs 2013; 38:64-72. [DOI: 10.1111/aor.12181] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Shigang Wang
- Pediatric Cardiovascular Research Center; Penn State Hershey Children's Hospital; Penn State Milton S. Hershey Medical Center; Department of Pediatrics; Penn State Hershey College of Medicine; Hershey USA
| | - Allen R. Kunselman
- Department of Public Health Sciences; Penn State Hershey College of Medicine; Hershey USA
| | - Akif Ündar
- Pediatric Cardiovascular Research Center; Penn State Hershey Children's Hospital; Penn State Milton S. Hershey Medical Center; Department of Pediatrics; Penn State Hershey College of Medicine; Hershey USA
- Department of Surgery; Penn State Milton S. Hershey Medical Center; Penn State Hershey College of Medicine; Pennsylvania State University; Hershey USA
- Department of Bioengineering; College of Engineering; Pennsylvania State University; University Park PA USA
| |
Collapse
|
6
|
Ündar A, Akçevin A, Alkan-Bozkaya T, Bakır I, Pauliks L, Palanzo D, Durandy Y, Ersayin-Kantas H, Ravishankar C, Gruenwald CE, Sandica E, Sun K, Türköz R, Pekkan K, Ceyran H, Weaver B, Pierce WS, Myers JL. Outcomes of the Eighth International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion. Artif Organs 2013; 37:1-9. [PMID: 23305568 DOI: 10.1111/j.1525-1594.2012.01562.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
7
|
Undar A, Wang S, Krawiec C. Impact of a unique international conference on pediatric mechanical circulatory support and pediatric cardiopulmonary perfusion research. Artif Organs 2012; 36:943-50. [PMID: 23121202 DOI: 10.1111/j.1525-1594.2012.01563.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
There is no question that the International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion is a unique event that has had a significant impact on the treatment of neonatal, infantile, and pediatric cardiopulmonary patients around the globe since 2005. This annual event will continue as long as there is a need to fill the gap for underserved patient population. It will also continue to recognize promising young investigators based on their full manuscripts for young investigator awards.
Collapse
|
8
|
Ündar A, Akçevin A, Pauliks LB, Palanzo D, Durandy Y, Myers JL. Welcome to the 8th International Conference on Pediatric Mechanical Circulatory Support Systems & Pediatric Cardiopulmonary Perfusion. Artif Organs 2012; 36:460-2. [PMID: 22568503 DOI: 10.1111/j.1525-1594.2012.01450.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|