1
|
Gabriels JK, Kim BS, Shoda M, Birgersdotter-Green U, Di Cori A, Zucchelli G, Curnis A, Arabia G, Epstein LM. International experience with transvenous lead extractions of an active-fixation coronary sinus pacing lead. Heart Rhythm 2024; 21:686-687. [PMID: 38219890 DOI: 10.1016/j.hrthm.2024.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 12/20/2023] [Accepted: 01/07/2024] [Indexed: 01/16/2024]
Affiliation(s)
- James K Gabriels
- Northwell, Cardiovascular Institute, North Shore University Hospital, New Hyde Park, New York.
| | - Beom Soo Kim
- Northwell, Cardiovascular Institute, North Shore University Hospital, New Hyde Park, New York
| | - Morio Shoda
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Tokyo, Japan
| | | | - Andrea Di Cori
- Second Division of Cardiology, Cardiac-Thoracic-Vascular Department, Azienda Ospedaliero Universitaria Pisana, University of Pisa, Pisa, Italy
| | - Giulio Zucchelli
- Second Division of Cardiology, Cardiac-Thoracic-Vascular Department, Azienda Ospedaliero Universitaria Pisana, University of Pisa, Pisa, Italy
| | - Antonio Curnis
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Gianmarco Arabia
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Laurence M Epstein
- Northwell, Cardiovascular Institute, North Shore University Hospital, New Hyde Park, New York
| |
Collapse
|
2
|
Hayashi K, Younis A, Callahan T, Baranowski B, Martin DO, Nakhla S, Wilkoff BL. Clinical Predictors of Incomplete CS Lead Removal during Transvenous Lead Extraction in the Patients with Cardiac Resynchronization Therapy. Heart Rhythm 2023; 20:872-878. [PMID: 36933853 DOI: 10.1016/j.hrthm.2023.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/24/2023] [Accepted: 03/13/2023] [Indexed: 03/20/2023]
Abstract
BACKGROUND Reports of coronary sinus (CS) lead removal include small studies with short implant durations. Procedural outcomes for mature CS leads removed with long duration implantation are unavailable. OBJECTIVE To examine the safety, efficacy, and clinical predictors for incomplete CS lead removal by Transvenous Lead Extraction (TLE) in a large, long implant duration cardiac resynchronization therapy (CRT) patient cohort. METHODS Consecutive patients with CRT devices in the Cleveland Clinic Prospective TLE Registry who had TLE between 2013 and 2022. RESULTS CS leads, n=231, implant duration = 6.1±4.0 years, removed from 226 patients were included, employing powered sheaths for 137 leads (59.3%). Complete CS lead success was achieved in 95.2% of leads (n=220) and in 95.6% of patients (n=216). Major complications occurred in 5 patients (2.2%). Patients who had the CS lead extracted 1st had significantly higher incomplete removal rates than when the other leads were 1st removed. Multivariable analysis showed that older CS lead age (OR 1.35, 95% CI 1.01-1.82; P = 0.03), and removing the CS lead 1st (OR 7.48, 95% CI 1.02-54.95; P = 0.045) were independent predictors of incomplete CS lead removal. CONCLUSION Complete and safe lead removal rate of long implant duration CS leads by TLE was 95%. However, CS lead age and the order that leads were extracted were the independent predictors of incomplete CS lead removal. Therefore, before the CS lead is extracted, physicians should first extract the leads from the other chambers and employ powered sheaths.
Collapse
Affiliation(s)
- Katsuhide Hayashi
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States
| | - Arwa Younis
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States
| | - Thomas Callahan
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States
| | - Bryan Baranowski
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States
| | - David O Martin
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States
| | - Shady Nakhla
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States
| | - Bruce L Wilkoff
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, United States.
| |
Collapse
|
3
|
Ahmed A, Arabia G, Bontempi L, Cerini M, Salghetti F, Muneretto C, Mitacchione G, Milidoni A, Curnis A. Hybrid transvenous and surgical approach for the extraction of coronary sinus leads: A case series. Pacing Clin Electrophysiol 2022; 45:861-865. [PMID: 35596733 PMCID: PMC9541447 DOI: 10.1111/pace.14536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 04/14/2022] [Accepted: 05/13/2022] [Indexed: 11/29/2022]
Abstract
Background Transvenous lead extraction is the standard therapy for cardiac device‐related infection. In some patients, however, a hybrid surgical and transvenous approach may be necessary. Methods and Results We present three cases who underwent transvenous lead extraction for an infected CRT‐D system. In all cases the CS lead could not be retrieved transvenously due to extensive fibrosis. The lead was successfully extracted through left minithoracotomy in two patients and midline sternotomy in one patient. Conclusion In cases where the coronary sinus lead shows severe fibrosis, a transvenous approach can be used to free the proximal part of the lead, while the distal adhesions can be removed surgically through a limited thoracic incision.
Collapse
Affiliation(s)
- Ashraf Ahmed
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy.,Cardiology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| | - Gianmarco Arabia
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Luca Bontempi
- Department of Cardiology, Asst Bergamo Est, Bolognini Hospital, Seriate, Bergamo, Italy
| | - Manuel Cerini
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Francesca Salghetti
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Claudio Muneretto
- Department of Cardiac Surgery, Spedali Civili di Brescia, University of Brescia, Brescia, Italy
| | - Gianfranco Mitacchione
- Department of Cardiology, Asst-Fatebenefratelli Sacco, Luigi Sacco University Hospital, Milan, Italy
| | - Antonino Milidoni
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| | - Antonio Curnis
- Cardio-Thoracic Department, Electrophysiology and Electrostimulation Laboratory, University of Brescia, Spedali Civili di Brescia, Brescia, Italy
| |
Collapse
|
4
|
Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems? INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19105803. [PMID: 35627340 PMCID: PMC9141355 DOI: 10.3390/ijerph19105803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 05/03/2022] [Accepted: 05/07/2022] [Indexed: 02/05/2023]
Abstract
Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters as well as the efficacy and safety of TLE were compared between patients with infected CRT and pacemakers (PM) and ICD systems. Results: Infectious indications for TLE occurred in 1138 patients, including 150 infected CRT (112 CRT-D and 38 CRT-P). The general health condition of CRT patients was worse with higher Charlson’s comorbidity index. The number of extracted leads was higher in the CRT group, but implant duration was significantly longer in the PM than in the ICD and CRT groups (98.93 vs. 55.26 vs. 55.43 months p < 0.01). The procedure was longer in duration, more difficult, and more complex in patients with pacemakers than in those in the CRT group. The occurrence of major complications and clinical and procedural success as well as procedure-related death did not show any relationship to the type of CIED device. Mortality at more than one-year follow-up after TLE was significantly higher among patients with CRT devices (22.7% vs. 8.7%) than among those in the PM group. Conclusion: Despite the greater burden of lead and comorbidities, the complexity and efficiency of removing infected CRT systems is no more dangerous than removing other infected systems. The duration of the implant seems to play a dominant role.
Collapse
|
5
|
Mehta VS, O'Brien H, Elliott MK, Sidhu BS, Gould J, Shetty AK, Niederer S, Rinaldi CA. Assessing long-term survival and hospitalization following transvenous lead extraction in patients with cardiac resynchronization therapy devices: A propensity score-matched analysis. Heart Rhythm O2 2022; 2:597-606. [PMID: 34988504 PMCID: PMC8703147 DOI: 10.1016/j.hroo.2021.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background Longer-term outcomes of patients post transvenous lead extraction (TLE) are poorly understood in patients with cardiac resynchronization therapy (CRT) devices. Objectives A propensity score (PS)–matched analysis evaluating outcomes post TLE in CRT and non-CRT populations was performed. Methods Data from consecutive patients undergoing TLE between 2000 and 2019 were prospectively collected. Patients surviving to discharge and reimplanted with the same device were included. The cohort was split depending on presence of CRT device. Associations with all-cause mortality and hospitalization were assessed by Kaplan-Meier estimates. An exploratory endpoint was evaluated whether early (<7 days) or late (>7 days) reimplantation was associated with poorer outcomes. Results Of 1005 patients included, 285 (25%) had a CRT device. Median follow-up was 57.00 [27.00–93.00] months, age at explant was 67.7 ± 12.1 years, 83.3% were male, and 54.4% had an infective indication for TLE. PS was calculated using 43 baseline characteristics. After matching, 192 CRT patients were compared with 192 non-CRT patients. In the matched cohort, no significant difference with respect to mortality (hazard ratio [HR] = 1.01, 95% confidence interval [CI] [0.74–1.39], P = .093) or hospitalization risk (HR = 1.2, 95% CI [0.87–1.66], P = .265) was observed. In the matched CRT group, late reimplantation was associated with increased mortality (HR = 1.64, [1.04–2.57], P = .032) and hospitalization risk (HR = 1.57, 95% CI [1.00–2.46], P = .049]. Conclusion Outcomes of CRT patients post TLE are similarly as poor as those of non-CRT patients in matched populations. Reimplantation within 7 days was associated with better outcomes in a CRT population but was not observed in a non-CRT population, suggesting prolonged periods without biventricular pacing should be avoided.
Collapse
Affiliation(s)
- Vishal S Mehta
- Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Hugh O'Brien
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Mark K Elliott
- Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Baldeep S Sidhu
- Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Justin Gould
- Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Anoop K Shetty
- Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Steven Niederer
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Christopher A Rinaldi
- Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.,School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
6
|
Yagishita D, Shoda M, Saito S, Kataoka S, Yazaki K, Kanai M, Ejima K, Hagiwara N. Technical Features and Clinical Outcomes of Coronary Venous Left Ventricular Lead Removal and Reimplantation. Circ J 2021; 85:1349-1355. [PMID: 33814523 DOI: 10.1253/circj.cj-20-1199] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The number of patients undergoing cardiac resynchronization therapy has increased. Consequently, there is increased frequency in the removal and reimplantation of coronary venous (CV) leads due to infection or malfunction.Methods and Results:A total of 345 consecutive patients referred for lead(s) extraction were reviewed. Of these, 34 patients who underwent a CV lead removal were investigated. The indications for CV leads removal were device-related infections in 29 patients and lead malfunctions in 5 patients. The average duration of the CV leads was 4.1±3.8 years. All CV leads were successfully removed without any major complications, except for 1 in-hospital death. Successful CV lead removal by simple traction (ST) was achieved in 21 patients (62%), whereas extraction tools were required in 13 patients (38%). Local infection and CV lead dwell time were significantly associated with successful ST (P=0.04 and P=0.014, respectively). CV lead re-implantation was successfully performed in 25 patients; however, a right-side approach was required in 92%, and occlusion/stenosis of the previous CV was observed in 80% of the patients. CONCLUSIONS CV lead removal is relatively successful and safe. The presence of local infection and a shorter lead duration may enable successful ST of a CV lead. However, the re-implantation procedure should be well prepared for the complexity related to the right-side approach and occlusion/stenosis of the previous CV.
Collapse
Affiliation(s)
| | - Morio Shoda
- Department of Cardiology, Tokyo Women's Medical University.,Clinical Research Division for Heart Rhythm Management, Tokyo Women's Medical University
| | - Satoshi Saito
- Department of Cardiovascular Surgery, Tokyo Women's Medical University
| | - Shohei Kataoka
- Department of Cardiology, Tokyo Women's Medical University
| | | | - Miwa Kanai
- Department of Cardiology, Tokyo Women's Medical University
| | - Koichiro Ejima
- Department of Cardiology, Tokyo Women's Medical University.,Clinical Research Division for Heart Rhythm Management, Tokyo Women's Medical University
| | | |
Collapse
|
7
|
Guella E, Brack M, Abozguia K, Cassidy CJ. First experience in quadripolar active fixation coronary sinus lead extraction: a case report. Eur Heart J Case Rep 2020; 4:1-5. [PMID: 33426434 PMCID: PMC7780495 DOI: 10.1093/ehjcr/ytaa184] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 03/27/2020] [Accepted: 05/29/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND The Attain Stability Quadripolar 4798 lead is a relatively new quadripolar active fixation coronary sinus (CS) lead. No cases of extraction of a chronically implanted 4798 lead have been published to date. CASE SUMMARY A 52-year-old man with a history of previous cardiac resynchronization therapy pacemaker (CRT-P) insertion and atrioventricular node ablation presented to our institution with a pocket infection 69 weeks after implantation. Directed intravenous antibiotic therapy was commenced and an extraction was performed the following day. Extraction of the right atrial and right ventricular leads was simple and achieved with gentle manual traction. Extraction of the CS lead was more difficult. Significant traction was required due to the formation of adhesions inside the CS but extraction of the lead was eventually successful without complication. Specialized extraction equipment was not required. A new contralateral CRT-P device was implanted, and the patient was discharged home. He remains well at 3 months of follow-up. DISCUSSION We present the first case of extraction of a chronically implanted active fixation Attain Stability Quadripolar lead. Our experience demonstrates that this has been performed successfully without specialist tools and with preservation of the CS branch. Significant adhesion was noted at the site of active fixation, however. Potential difficulty with this lead's extraction should therefore be considered when contemplating its use.
Collapse
Affiliation(s)
- Elhosseyn Guella
- Cardiology Department, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire FY3 8NR, UK
| | - Michael Brack
- Cardiology Department, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire FY3 8NR, UK
| | - Khalid Abozguia
- Cardiology Department, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire FY3 8NR, UK
| | - Christopher John Cassidy
- Cardiology Department, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire FY3 8NR, UK
| |
Collapse
|
8
|
Safety and effectiveness of coronary sinus leads extraction - single high-volume centre experience. ADVANCES IN INTERVENTIONAL CARDIOLOGY 2019; 15:345-356. [PMID: 31592259 PMCID: PMC6777180 DOI: 10.5114/aic.2019.87890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Accepted: 04/07/2019] [Indexed: 11/17/2022] Open
Abstract
Introduction Transvenous leads extraction (TLE) of permanently implanted coronary sinus (CS) leads is widely believed to present greater risks than the removal of other leads. Aim To assess the safety and efficacy of CS leads extraction based on large research material obtained by one operator performing procedures in two TLE centres. Material and methods We extracted 408 CS leads from 389 patients, and the results were compared to a control group of 2465 patients who underwent non-CS lead TLE procedures. Results There were no significant differences in the clinical success rate (97.9% vs. 98.0%) or the major complication rate (2.1% vs. 1.8%) between the CS and control group. CS lead destination (LV/LA pacing) and tip location (CS ostium/mid CS /CS tributaries) influenced the procedural and radiological success rates and procedural complexity but not the complications. CS lead extraction did not affect the necessity for a cardiosurgical intervention or presence of procedure-related death. Conclusions TLE of CS leads can be achieved with a high procedural success rate. The major complication rate is not higher than that seen in non-CS lead extraction patients. More than half of CS leads cannot be removed by simple traction and the use of mechanical sheaths may be necessary. The detachment of CS leads from connective tissue scars in the venous and atrial areas up to the CS ostium is generally sufficient for further removal of the lead using simple traction.
Collapse
|
9
|
Gould J, Sidhu B, Porter B, Sieniewicz BJ, Teall T, Williams S, Shetty A, Bosco P, Blauth C, Gill J, Rinaldi CA. Prolonged lead dwell time and lead burden predict bailout transfemoral lead extraction. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2019; 42:1355-1364. [DOI: 10.1111/pace.13791] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 07/31/2019] [Accepted: 08/18/2019] [Indexed: 01/02/2023]
Affiliation(s)
- Justin Gould
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Baldeep.S. Sidhu
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Bradley Porter
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Benjamin. J. Sieniewicz
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Thomas Teall
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Steven.E. Williams
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Anoop Shetty
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Paolo Bosco
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
| | - Christopher Blauth
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
| | - Jaswinder Gill
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| | - Christopher. A. Rinaldi
- Cardiology DepartmentGuy's and St Thomas’ NHS Foundation Trust London UK
- School of Biomedical Engineering and Imaging SciencesKing's College London London UK
| |
Collapse
|
10
|
Zheng W, Li D, Li X, Ze F, Wang L, Duan J, Yuan C. Cardiac resynchronization therapy coronary venous left ventricular lead removal and reimplantation: Experience from a single center in China. Exp Ther Med 2019; 18:2213-2218. [PMID: 31452711 DOI: 10.3892/etm.2019.7818] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 06/27/2019] [Indexed: 11/05/2022] Open
Abstract
The present study aimed to investigate the success rate, methods and associated complications of left ventricular lead (LVL) extraction and venous pathway reimplantation in patients with cardiac resynchronization therapy device/defibrillator (CRT/CRTD). A retrospective analysis was performed in the patients who underwent CRT/CRTD extraction and reimplantation at our hospital from January 2012 to October 2018. The methods, patient complications and success rate of extraction and reimplantation of LVL were analyzed. A total of 54 patients underwent CRT/CRTD removal (pacemaker infection, n=51; LVL dysfunction, n=3; CRT/CRTD, 34/20). A total of 54 LVLs were removed (3 active electrodes and 51 passive electrodes). The average implantation duration of the LVL was 53.5 months (range, 1-204 months), whereas the success rate of the LVL extraction was 100% (94% completely removed and 6% clinically removed. A total of 6 patients (11%) were treated only by manual traction, whereas the remaining patients had their LVL successfully removed using extraction tools. In the peri-operative period, one fatality occurred (2%). The highest complication rate of the lead extraction was 2% and no minor complications were observed. A total of 36 patients were reimplanted on the right side, which was successful in 31 cases (success rate, 86.1%), whereas 3 cases were successfully reimplanted on the left side. The total success rate of LVL reimplantation was 87.2%. The procedure of the LVL removal and reimplantation exhibited a high success rate and a lower incidence of complications compared with that in patients with cardiac devices.
Collapse
Affiliation(s)
- Wencheng Zheng
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Ding Li
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Xuebin Li
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Feng Ze
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Long Wang
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Jiangbo Duan
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Cuizhen Yuan
- Department of Cardiac Electrophysiology, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| |
Collapse
|
11
|
Gould J, Klis M, Porter B, Sieniewicz BJ, Sidhu BS, Claridge S, Williams SE, Shetty A, O’Neill M, Gill J, Rinaldi CA. Transvenous lead extraction in patients with cardiac resynchronization therapy devices is not associated with increased 30-day mortality. Europace 2018; 21:928-936. [DOI: 10.1093/europace/euy290] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 11/14/2018] [Indexed: 12/30/2022] Open
Affiliation(s)
- Justin Gould
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Magdalena Klis
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Bradley Porter
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Benjamin J Sieniewicz
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Baldeep S Sidhu
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Simon Claridge
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Steven E Williams
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Anoop Shetty
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Mark O’Neill
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Jaswinder Gill
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| | - Christopher A Rinaldi
- Department of Cardiology, Lower Ground Floor, South Wing, Guy’s and St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, UK
| |
Collapse
|
12
|
Keiler J, Schulze M, Sombetzki M, Heller T, Tischer T, Grabow N, Wree A, Bänsch D. Neointimal fibrotic lead encapsulation - Clinical challenges and demands for implantable cardiac electronic devices. J Cardiol 2017; 70:7-17. [PMID: 28583688 DOI: 10.1016/j.jjcc.2017.01.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 01/16/2017] [Indexed: 01/09/2023]
Abstract
Every tenth patient with a cardiac pacemaker or implantable cardioverter-defibrillator implanted is expected to have at least one lead problem in his lifetime. However, transvenous leads are often difficult to remove due to thrombotic obstruction or extensive neointimal fibrotic ingrowth. Despite its clinical significance, knowledge on lead-induced vascular fibrosis and neointimal lead encapsulation is sparse. Although leadless pacemakers are already available, their clinical operating range is limited. Therefore, lead/tissue interactions must be further improved in order to improve lead removals in particular. The published data on the coherences and issues related to lead associated vascular fibrosis and neointimal lead encapsulation are reviewed and discussed in this paper.
Collapse
Affiliation(s)
- Jonas Keiler
- Department of Anatomy, Rostock University Medical Center, Rostock, Germany.
| | - Marko Schulze
- Department of Anatomy, Rostock University Medical Center, Rostock, Germany
| | - Martina Sombetzki
- Department for Tropical Medicine and Infectious Diseases, Rostock University Medical Center, Rostock, Germany
| | - Thomas Heller
- Institute of Diagnostic and Interventional Radiology, Rostock University Medical Center, Rostock, Germany
| | - Tina Tischer
- Heart Center Rostock, Department of Internal Medicine, Divisions of Cardiology, Rostock University Medical Center, Rostock, Germany
| | - Niels Grabow
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Andreas Wree
- Department of Anatomy, Rostock University Medical Center, Rostock, Germany
| | | |
Collapse
|
13
|
Cronin EM. Coronary Venous Lead Extraction. J Innov Card Rhythm Manag 2017; 8:2758-2764. [PMID: 32494456 PMCID: PMC7252920 DOI: 10.19102/icrm.2017.080604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Accepted: 04/18/2017] [Indexed: 11/06/2022] Open
Abstract
The increasing number of cardiac resynchronization therapy devices implanted, coupled with the increasing incidence of cardiac implantable electronic device infection, has led to a greater need for extraction of coronary venous pacing leads. The objectives of this study were to review the indications, techniques and published results of coronary venous lead extraction. In this study, we searched PubMed using the search terms "lead extraction," "coronary sinus," "coronary venous," "pacing," and "cardiac resynchronization therapy" for relevant papers. The reference lists of relevant articles were also searched, and personal experience was drawn upon. Published success rates and complications were found to be similar to those reported for non-coronary venous leads in experienced centers. However, reimplantation success differs and can be limited by vessel occlusion postextraction. The available active fixation coronary sinus lead (Attain Starfix™; Medtronic, MN, USA) is a particularly complex lead to extract, whereas limited data on the newer active fixation leads (Attain Stability™, Medtronic, MN, USA) suggest that they are less challenging to remove. The study concluded that coronary venous lead extraction presents unique challenges, especially reimplantation, that require special consideration and planning to overcome.
Collapse
Affiliation(s)
- Edmond M Cronin
- Hartford HealthCare Heart and Vascular Institute at Hartford Hospital, Hartford, CT.,University of Connecticut School of Medicine, Farmington, CT
| |
Collapse
|
14
|
|
15
|
Pecha S, Kennergren C, Yildirim Y, Gosau N, Aydin A, Willems S, Treede H, Reichenspurner H, Hakmi S. Coronary Sinus Lead Removal: A Comparison between Active and Passive Fixation Leads. PLoS One 2016; 11:e0153651. [PMID: 27119368 PMCID: PMC4847909 DOI: 10.1371/journal.pone.0153651] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 04/02/2016] [Indexed: 11/28/2022] Open
Abstract
Background Implantation of coronary sinus (CS) leads may be a difficult procedure due to different vein anatomies and a possible lead dislodgement. The mode of CS lead fixation has changed and developed in recent years. Objectives We compared the removal procedures of active and passive fixation leads. Methods Between January 2009 and January 2014, 22 patients at our centre underwent CS lead removal, 6 active and 16 passive fixation leads were attempted using simple traction or lead locking devices with or without laser extraction sheaths. Data on procedural variables and success rates were collected and retrospectively analyzed. Results The mean patient age was 67.2 ± 9.8 years, and 90.9% were male. The indication for lead removal was infection in all cases. All active fixation leads were Medtronic® Attain StarFix™ Model 4195 (Medtronic Inc., Minneapolis, MN, USA). The mean time from implantation for the active and passive fixation leads was 9.9 ± 11.7 months (range 1.0–30.1) and 48.7 ± 33.6 months (range 5.7–106.4), respectively (p = 0.012). Only 3 of 6 StarFix leads were successfully removed (50%) compared to 16 of 16 (100%) of the passive fixation CS leads (p = 0.013). No death or complications occurred during the 30-day follow-up. Conclusion According to our experience, removal of the Starfix active fixation CS leads had a higher procedural failure rate compared to passive.
Collapse
Affiliation(s)
- Simon Pecha
- Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany
- * E-mail:
| | - Charles Kennergren
- Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Göteborg, Sweden
| | - Yalin Yildirim
- Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany
| | - Nils Gosau
- Department of Cardiology, Electrophysiology, University Heart Center Hamburg, Hamburg, Germany
| | - Ali Aydin
- Department of Cardiology, St. Adolf-Stift Hospital Reinbek, Reinbek, Germany
| | - Stephan Willems
- Department of Cardiology, Electrophysiology, University Heart Center Hamburg, Hamburg, Germany
| | - Hendrik Treede
- Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany
| | | | - Samer Hakmi
- Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany
| |
Collapse
|
16
|
Golzio PG, Meynet I, Orzan F, Pellissero E, Castagno D, Ferraris F, Gaita F. Starfix lead extraction: Clinical experience and technical issues. J Cardiol Cases 2016; 13:25-30. [PMID: 30546604 PMCID: PMC6281896 DOI: 10.1016/j.jccase.2015.09.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Revised: 09/08/2015] [Accepted: 09/15/2015] [Indexed: 11/29/2022] Open
Abstract
Transvenous lead extraction (TLE) of the Starfix coronary sinus (CS) active-fixation lead may be challenging, due to undeployment of fixation lobes and venous occlusion. We report our experience in Starfix TLE, in comparison with previous data. A 78-year-old male, implanted in 2009 with Starfix lead, was referred to our institution for TLE, due to infective endocarditis with lead-associated vegetations. The tip of Starfix lead was located in distant, anterior position, in the great cardiac vein, close to patent left internal mammary artery-to-left anterior descending artery anastomosis, and first-choice surgical removal had a prohibitive operative risk. Conventional dilatation beyond CS ostium, as well as the use of a standard delivery catheter, was ineffective. An off-label modification of the delivery, by cutting the distal soft tip, was successful. However, the tip of the lead fragmented and was trapped in the innominate vein. Then a gooseneck snare grasped the fragment, allowing complete retrieval. TLE of Starfix leads may be particularly challenging, especially when its tip is located in a distant anterior location. In these cases, important help may be obtained by dilatation within the CS, by means of conventional or modified delivery catheters. Only experienced operators, sometimes with non-conventional techniques, should perform TLE of Starfix leads. .
Collapse
Affiliation(s)
- Pier Giorgio Golzio
- Division of Cardiology, Department of Internal Medicine, Azienda Ospedaliero-Universitaria Città della Salute e della Scienza di Torino, Turin, Italy
| | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
Expanded indications for cardiac resynchronization therapy and the increasing incidence of cardiac implantable electronic device infection have led to an increased need for coronary sinus (CS) lead extraction. The CS presents unique anatomical obstacles to successful lead extraction. Training and facility requirements for CS lead extraction should mirror those for other leads. Here we review the indications, technique, and results of CS lead extraction. Published success rates and complications are similar to those reported for other leads, although multiple techniques may be required. Re-implantation options may be limited, which should be incorporated into pre-procedural decision making.
Collapse
Affiliation(s)
- Edmond M Cronin
- Division of Cardiology, Hartford Hospital, 80 Seymour Street PO Box 5037, Hartford CT 06102, USA.
| | - Bruce L Wilkoff
- Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue, Cleveland OH 44195, USA
| |
Collapse
|
18
|
Di Monaco A, Pelargonio G, Narducci ML, Manzoli L, Boccia S, Flacco ME, Capasso L, Barone L, Perna F, Bencardino G, Rio T, Leo M, Di Biase L, Santangeli P, Natale A, Rebuzzi AG, Crea F. Safety of transvenous lead extraction according to centre volume: a systematic review and meta-analysis. Europace 2014; 16:1496-507. [PMID: 24965015 DOI: 10.1093/europace/euu137] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Transvenous lead extraction (TLE) is a complex invasive procedure and the experience of the operator and the team is a major determinant of procedural outcomes. AIM Because of very limited data available on minimum procedural volumes to enable training and ongoing competency for TLEs, we performed a meta-analysis aimed at assessing the outcomes of TLE in the centres with low, medium, and high volume of procedures. METHODS Of the 280 papers initially retrieved until February 2013, 66 observational studies met inclusion criteria and were included in at least one stratified meta-analysis: 17 were prospective studies; 47 had a retrospective design; and 2 were defined 'experience studies'. We included only articles published after the introduction of laser technique (year 1999). We divided the studies in low, medium, and high volume centres utilizing either the European Heart Rhythm Association (EHRA) or Lexicon classification criteria. RESULTS When meta-analyses were carried out separately for the studies with larger and smaller sample sizes, either using EHRA or Lexicon classification criteria, no clear differences emerged in the combined rate of major complications or intraoperative deaths. In contrast, both minor complications and mortality at 30 days decreased as centre volume increased. CONCLUSIONS In our meta-analysis of observational studies, patients who have been treated in higher volume centres have a lower probability of minor complications and death at 30 days regardless of the infection rate, length of lead duration, type of device, and type of extraction.
Collapse
Affiliation(s)
- Antonio Di Monaco
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Gemma Pelargonio
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Maria Lucia Narducci
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Lamberto Manzoli
- Department of Medicine and Aging Sciences, University 'G D'Annunzio' Chieti, Chieti, Italy
| | - Stefania Boccia
- Institute of Hygiene, Catholic University of Sacred Heart, Rome, Italy
| | - Maria Elena Flacco
- Department of Medicine and Aging Sciences, University 'G D'Annunzio' Chieti, Chieti, Italy
| | - Lorenzo Capasso
- Department of Medicine and Aging Sciences, University 'G D'Annunzio' Chieti, Chieti, Italy
| | - Lucy Barone
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Francesco Perna
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Gianluigi Bencardino
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Teresa Rio
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Milena Leo
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Luigi Di Biase
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, NY, USA Department of Cardiology, University of Foggia, Foggia, Italy
| | - Pasquale Santangeli
- Department of Cardiology, University of Foggia, Foggia, Italy Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA
| | - Antonio Giuseppe Rebuzzi
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - Filippo Crea
- Department of Cardiovascular Sciences, Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| |
Collapse
|
19
|
Madhavan M, Swale MJ, Gard JJ, Hayes DL, Asirvatham SJ. Contemporary pacemaker and ICD lead management: techniques for lead extraction. Expert Rev Cardiovasc Ther 2014; 10:875-87. [DOI: 10.1586/erc.12.75] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
20
|
Lisy M, Kornberger A, Schmid E, Kalender G, Stock UA, Doernberger V, Steger V. Application of Intravascular Dissection Devices for Closed Chest Coronary Sinus Lead Extraction: An Interdisciplinary Approach. Ann Thorac Surg 2013; 95:1360-5. [DOI: 10.1016/j.athoracsur.2012.12.051] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2012] [Revised: 12/13/2012] [Accepted: 12/21/2012] [Indexed: 12/01/2022]
|
21
|
Pelargonio G, Narducci ML. Transvenous lead extractions in CRT patients: the end is only the beginning. J Cardiovasc Electrophysiol 2012; 23:1217-8. [PMID: 23148987 DOI: 10.1111/j.1540-8167.2012.02404.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
Active fixation mechanism complicates coronary sinus lead extraction and limits subsequent reimplantation targets. J Interv Card Electrophysiol 2012; 36:81-6; discussion 86. [DOI: 10.1007/s10840-012-9704-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2012] [Accepted: 05/30/2012] [Indexed: 10/28/2022]
|
23
|
RICKARD JOHN, TARAKJI KHALDOUN, CRONIN EDMOND, BRUNNER MICHAELP, JACKSON GREGORY, BARANOWSKI BRYAN, BOREK PETERP, MARTIN DAVIDO, WAZNI OUSSAMA, WILKOFF BRUCEL. Cardiac Venous Left Ventricular Lead Removal and Reimplantation Following Device Infection: A Large Single-Center Experience. J Cardiovasc Electrophysiol 2012; 23:1213-6. [DOI: 10.1111/j.1540-8167.2012.02392.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
24
|
Maytin M, Carrillo RG, Baltodano P, Schaerf RHM, Bongiorni MG, Di Cori A, Curnis A, Cooper JM, Kennergren C, Epstein LM. Multicenter experience with transvenous lead extraction of active fixation coronary sinus leads. Pacing Clin Electrophysiol 2012; 35:641-7. [PMID: 22432739 DOI: 10.1111/j.1540-8159.2012.03353.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND/OBJECTIVE Active fixation coronary sinus (CS) leads limit dislodgement and represent an attractive option to the implanter. Although extraction of passive fixation CS leads is a common and frequently uncomplicated procedure, data regarding extraction of chronically implanted active fixation CS leads are limited. METHODS We performed a retrospective cohort study of patients undergoing active fixation CS lead extraction at six centers. Patient and procedural characteristics, indications for extraction, use of extraction sheath (ES) assistance, and outcomes are reported. RESULTS Between January 2009 and February 2011, 12 patients underwent transvenous lead extraction (TLE) of Medtronic StarFix® lead (Medtronic Inc., Minneapolis, MN, USA). The cohort was 83% male with mean age 71 ± 14 years. Average implant duration was 14.2 ± 5.7 months (2.3-23.6). All leads but one were removed for infectious indications (67% systemic infection). At the time of explant, the fixation lobes were completely retracted in only one of the 12 cases and ES assistance was required for lead removal in all cases (58% laser, 25% cutting, 25% mechanical, and 25% femoral). The majority of cases required advancement of the sheath into the CS (75.0%) and often into a branch vessel (41.7%). One lead could not be removed transvenously and required surgical lead extraction. There were no major complications. Examination of the leads after extraction frequently revealed significant tissue growth into the fixation lobes. CONCLUSIONS Although TLE of active fixation CS leads can be a safe procedure in select patients and experienced hands, powered sheaths and aggressive techniques are frequently required for successful removal despite relatively short implant durations. This raises significant concern regarding future TLE of active fixation CS leads with longer implant durations.
Collapse
Affiliation(s)
- Melanie Maytin
- Cardiovascular Division, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Sheldon S, Friedman PA, Hayes DL, Osborn MJ, Cha YM, Rea RF, Asirvatham SJ. Outcomes and predictors of difficulty with coronary sinus lead removal. J Interv Card Electrophysiol 2012; 35:93-100. [PMID: 22584767 DOI: 10.1007/s10840-012-9685-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2011] [Accepted: 04/02/2012] [Indexed: 01/31/2023]
Abstract
With increasing coronary sinus (CS) pacemaker leads for cardiac resynchronization therapy, the need to remove these leads has risen. The purpose of this study is to describe a single center's experience with CS lead removal and to attempt to identify predictors of difficulty with lead removal and complications. We reviewed all percutaneous endocardial CS lead removals performed at our institution through February 2010. Successful removal with traction alone was considered simple while complex extractions required traction devices and/or laser sheaths. Between December 1996 and February 2010, 125 CS leads were percutaneously removed ≥1 week post-implantation from 115 patients. One attempt at CS lead extraction was unsuccessful. The average duration since implantation for the CS leads was 1.54 years (± .75 years, range 8 days to 8.24 years). The majority of the leads were removed by simple traction (n = 114, 91.2 %). The remainder were removed by femoral approach with snare (n = 3, 2.4 %), locking stylet (n = 2, 1.6 %), or locking stylet and laser sheath (n = 6, 4.8 %). Half of CS leads in place greater than 4 years required complex extraction (n = 7/14, 50 %). CS complications (n = 11 patients, 8.8 %) included CS or tributary thrombosis (n = 7/102, 6.9 %) and CS dissection (n = 4/102, 3.9 %). Major non-CS complications (n = 2 patients, 1.6 %) included a cardiac tear requiring pericardiocentesis and thoracotomy (n = 1, 0.8 %) and subclavian vein tear requiring surgical repair (n = 1, 0.8 %). Minor non-CS complications (n = 9 patients, 7.2 %) included a pneumothorax (n = 1, 0.8 %), hematoma (n = 2, 1.6 %), subclavian vein thrombosis (n = 3, x%), and blood transfusion (n = 5, 4.0 %). A longer duration since implantation and larger lead diameter were associated with complex versus simple removal (p < .0001 and p = .0009 respectively). Percutaneous CS lead removal is successful by simple traction alone in the vast majority of cases. CS leads in place greater than 4 years, however, often require complex extraction. Specific extraction techniques can be implemented when simple traction is unsuccessful without an appreciable increase in complications.
Collapse
Affiliation(s)
- Seth Sheldon
- Department of Internal Medicine, Mayo Clinic, Rochester, MN, USA
| | | | | | | | | | | | | |
Collapse
|