Gausz FD, Lena KNM, Gedeon PE, Miklos M, Benak A, Bencsik G, Makai A, Kranyak D, Gagyi RB, Pap R, Saghy L, Szili-Torok T, Vamos M. Arrhythmia Detection in Atrioventricular, Single-Lead, Floating Atrial Dipole ICD Systems Compared with Conventional Single- and Dual-Chamber Defibrillators. J Cardiovasc Dev Dis 2024; 11:386. [PMID: 39728276 DOI: 10.3390/jcdd11120386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2024] [Revised: 11/26/2024] [Accepted: 11/29/2024] [Indexed: 12/28/2024] Open
Abstract
BACKGROUND An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators. METHODS Data from consecutive patients undergoing ICD implantation were retrospectively analyzed. The primary endpoint was the incidence of device-detected, new-onset atrial arrhythmias, while secondary endpoints were sensing parameters, complication rates, incidence of appropriate/inappropriate ICD therapy, arrhythmic/heart failure-related hospitalizations, and all-cause mortality. RESULTS A total of 256 patients (mean age 64 ± 12 years, male 75%, primary prophylaxis 28%, mean follow-up 3.7 ± 2.4 years) were included (VVI: 93, VDD: 94, DDD: 69). Atrial arrhythmia episodes were detected more frequently by VDD systems compared to VVI ICDs (aHR 7.087; 95% CI 2.371-21.183; p < 0.001), and at a rate similar to that of DDD ICDs (aHR 1.781; 95% CI 0.737-4.301; p = 0.200). The rate of inappropriate shocks was not different among the three ICD systems. CONCLUSION VDD devices revealed an advantage in atrial arrhythmia detection compared to VVI ICDs and were non-inferior to DDD systems. Their main indication may be closer monitoring in high-risk patients with atrial arrhythmias to help therapy optimization and not the improvement of tachycardia discrimination.
Collapse
Affiliation(s)
- Flora Diana Gausz
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Kom Nangob Manuela Lena
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
- Department of Oncotherapy, University of Szeged, 6720 Szeged, Hungary
| | - Paul Emmanuel Gedeon
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
- Neurosurgery, Queen Elizabeth University Hospital, G51 4TF Glasgow, UK
| | - Marton Miklos
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Attila Benak
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Gabor Bencsik
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Attila Makai
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Dora Kranyak
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Rita Beata Gagyi
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Robert Pap
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Laszlo Saghy
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Tamas Szili-Torok
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| | - Mate Vamos
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
| |
Collapse
|
2
|
Biffi M, Statuto G, Calvi V, Iori M, De Maria E, Bolognesi MG, Allocca G, Notarangelo F, Carinci V, Ammendola E, Boggian G, Saporito D, Mancini L, Potenza D, Celentano E, Giorgi D, Ziacchi M. Inappropriate therapies in modern implantable cardioverter-defibrillators: A propensity score-matched comparison between single- and dual-chamber discriminators in single-chamber devices THe sINGle lead Study (THINGS Study). Heart Rhythm 2024:S1547-5271(24)03417-9. [PMID: 39370028 DOI: 10.1016/j.hrthm.2024.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 09/17/2024] [Accepted: 10/01/2024] [Indexed: 10/08/2024]
Abstract
BACKGROUND In patients with implantable cardioverter-defibrillators (ICDs), inappropriate therapies (ITs) are often caused by supraventricular tachyarrhythmias (SVTs). OBJECTIVE We aimed to estimate the incidence of IT in modern single-lead ICDs. METHODS The THINGS study enrolled patients with single-lead ICDs with 2 SVT discrimination modalities: dual chamber (DC) with an atrial floating dipole or single chamber (SC) with morphology criterion. All devices were programmed with 2-zone therapy: ventricular tachycardia (VT) zone from 170 beats/min with ≥15 seconds (≥36 beats) detection time and SVT discriminators; and ventricular fibrillation (VF) zone from 214 beats/min with ≥7 seconds (≥24 beats) detection time. The primary end point was the first occurrence of IT, adjudicated by an independent board. RESULTS A total of 526 patients (median age, 66 years; 83% male), 183 (34.8%) with DC and 343 (65.2%) with SC discrimination, were observed for a median of 2.2 years. The incidence rate of IT was 4.2% (95% confidence interval [CI], 2.7%-6.4%) at 1 year and 7.1% (95% CI, 5.0%-9.9%) at 2 years. Younger age (adjusted hazard ratio, 0.97; 95% CI, 0.95-0.99; P = .013) and history of atrial fibrillation (adjusted hazard ratio, 2.67; 95% CI, 1.30-5.46; P = .007) were significantly associated with increased IT risk. In a propensity score-matched comparison, DC discrimination showed a trend toward reduced IT rates compared with SC discrimination in the VT zone (1-year incidence, 1.8% vs 3.5%; P = .105). CONCLUSION High-rate VF cutoff and prolonged detection time programming resulted in a low IT rate in single-lead ICD patients with modern SVT discriminators. A trend favoring the DC system was observed in the VT zone.
Collapse
Affiliation(s)
- Mauro Biffi
- Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy.
| | - Giovanni Statuto
- Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy
| | - Valeria Calvi
- Department of Cardiology, Azienda O.U. Policlinico "G. Rodolico"-San Marco, Catania, Italy
| | - Matteo Iori
- Department of Cardiology, Unità Operativa di Cardiologia, Azienda Ospedaliera S. Maria Nuova, Reggio Emilia, Italy
| | - Elia De Maria
- Cardiology Unit, Ramazzini Hospital, Carpi, Modena, Italy
| | | | - Giuseppe Allocca
- Department of Cardiology, S. Maria dei Battuti Hospital, AULSS 2 Veneto, Conegliano, Italy
| | | | - Valeria Carinci
- Cardiology Unit, Azienda AUSL, Maggiore Hospital, Bologna, Italy
| | - Ernesto Ammendola
- Department of Cardiology, Monaldi Hospital, University "Vanvitelli," Naples, Italy
| | | | | | | | - Domenico Potenza
- UOC Cardiology, Fondazione "Casa Sollievo della Sofferenza" IRCCS, S. Giovanni Rotondo, Foggia, Italy
| | - Eduardo Celentano
- Department of Electrophysiology, Humanitas Gavazzeni, Bergamo, Italy
| | | | - Matteo Ziacchi
- Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy
| |
Collapse
|
3
|
Vamos M, Nemeth M, Kesoi B, Papp R, Polgar B, Ruppert M, Mikler C, Liptak A, Selley T, Balazs T, Szili-Torok T, Zima E, Zoltan Duray G. Key influences of VDD (DX) ICD selection: Results from a prospective, national survey. Pacing Clin Electrophysiol 2024; 47:893-901. [PMID: 38884620 DOI: 10.1111/pace.15028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 05/19/2024] [Accepted: 05/30/2024] [Indexed: 06/18/2024]
Abstract
BACKGROUND To preserve the benefit of atrial sensing without the implantation of an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD) has been developed. The purpose of this nationwide survey was to provide an overview of the current key influences of device selection focusing on DX ICD and to test the applicability of a previously published decision-making flowchart of ICD-type selection. METHODS An online questionnaire was sent to all implanting centers in Hungary. Eleven centers reported data from 361 DX ICD and 10 CRT-DX systems implantations between February 2021 and May 2023. RESULTS The most important influencing clinical factors indicated by the participating doctors were elevated risk of atrial fibrillation (AF)/stroke (56%), risk of sinus/supraventricular tachycardias (SVT) (42%), and a potential need for CRT upgrade in the future (36%). The DX ICD was considered in the majority of cases instead of the VVI system (87%), and only in a small proportion instead of a DDD ICD (13%). 60% of the patients with DX ICDs were also included into remote monitoring-based follow-up. In 83% of the cases, good (>2 mV) or excellent (>5) atrial signal amplitude was recorded within 6 weeks after the implantation. CONCLUSION In the current national survey, the most important influencing factors indicated by the implanters for selecting a DX ICD were the elevated risk of stroke or sinus/SVT and a potential need for CRT upgrade in the future. These findings support the use of a previously published decision-making flowchart.
Collapse
Affiliation(s)
- Mate Vamos
- Cardiology Center, University of Szeged, Szeged, Hungary
| | - Marianna Nemeth
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Bence Kesoi
- Department of Adult Cardiology, Gottsegen National Cardiovascular Center, Budapest, Hungary
| | - Roland Papp
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Balazs Polgar
- Central Hospital of Northern Pest - Military Hospital, Budapest, Hungary
| | - Mihaly Ruppert
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Csaba Mikler
- Borsod-Abaúj-Zemplén County Central Hospital and University Teaching Hospital, Miskolc, Hungary
| | | | | | | | | | - Endre Zima
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Gabor Zoltan Duray
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
- Central Hospital of Northern Pest - Military Hospital, Budapest, Hungary
| |
Collapse
|
4
|
Rai R, Singh V, Ahmad Z, Jain A, Jat D, Mishra SK. Autonomic neuronal modulations in cardiac arrhythmias: Current concepts and emerging therapies. Physiol Behav 2024; 279:114527. [PMID: 38527577 DOI: 10.1016/j.physbeh.2024.114527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/21/2024] [Accepted: 03/22/2024] [Indexed: 03/27/2024]
Abstract
The pathophysiology of atrial fibrillation and ventricular tachycardia that result in cardiac arrhythmias is related to the sustained complicated mechanisms of the autonomic nervous system. Atrial fibrillation is when the heart beats irregularly, and ventricular arrhythmias are rapid and inconsistent heart rhythms, which involves many factors including the autonomic nervous system. It's a complex topic that requires careful exploration. Cultivation of speculative knowledge on atrial fibrillation; the irregular rhythm of the heart and ventricular arrhythmias; rapid oscillating waves resulting from mistakenly inconsistent P waves, and the inclusion of an autonomic nervous system is an inconceivable approach toward clinical intricacies. Autonomic modulation, therefore, acquires new expansions and conceptions of appealing therapeutic intelligence to prevent cardiac arrhythmia. Notably, autonomic modulation uses the neural tissue's flexibility to cause remodeling and, hence, provide therapeutic effects. In addition, autonomic modulation techniques included stimulation of the vagus nerve and tragus, renal denervation, cardiac sympathetic denervation, and baroreceptor activation treatment. Strong preclinical evidence and early human studies support the annihilation of cardiac arrhythmias by sympathetic and parasympathetic systems to transmigrate the cardiac myocytes and myocardium as efficient determinants at the cellular and physiological levels. However, the goal of this study is to draw attention to these promising early pre-clinical and clinical arrhythmia treatment options that use autonomic modulation as a therapeutic modality to conquer the troublesome process of irregular heart movements. Additionally, we provide a summary of the numerous techniques for measuring autonomic tone such as heart rate oscillations and its association with cutaneous sympathetic nerve activity appear to be substitute indicators and predictors of the outcome of treatment.
Collapse
Affiliation(s)
- Ravina Rai
- Department of Zoology, School of Biological Sciences, Dr. Harisingh Gour Central University, Sagar 470003 MP, India
| | - Virendra Singh
- School of Biochemical Engineering, Indian Institute of Technology (Banaras Hindu University), Varanasi 221005 UP, India
| | - Zaved Ahmad
- Department of Zoology, School of Biological Sciences, Dr. Harisingh Gour Central University, Sagar 470003 MP, India
| | - Abhishek Jain
- Sanjeevani Diabetes and Heart Care Centre, Shri Chaitanya Hospital, Sagar, 470002, MP, India
| | - Deepali Jat
- Department of Zoology, School of Biological Sciences, Dr. Harisingh Gour Central University, Sagar 470003 MP, India.
| | | |
Collapse
|
5
|
Jiang J, Sun X, Chen R, Su Y, Xu W, Cheng C, Zhang S. Association between nighttime heart rate and cardiovascular mortality in patients with implantable cardioverter-defibrillator: A cohort study. Heart Rhythm 2023; 20:1682-1688. [PMID: 37689174 DOI: 10.1016/j.hrthm.2023.08.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/27/2023] [Accepted: 08/31/2023] [Indexed: 09/11/2023]
Abstract
BACKGROUND Although studies have shown that an increased resting heart rate measured randomly at a single point of the day has been associated with adverse cardiovascular outcomes, the utility of continuous monitoring of nighttime heart rate (NTHR) has remained largely uninvestigated. OBJECTIVE This study aimed to explore the association between NTHR and cardiovascular mortality. METHODS The Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device-implanted Patients, which is a prospective cohort study, enrolled patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator between 2010 and 2015. Baseline NTHR was measured during the programmed sleep period from 30 to 60 days after implantation. The primary outcome was cardiovascular mortality, fitted by a restricted cubic spline function. RESULTS A total of 534 implantable cardioverter-defibrillator recipients with sinus rhythm during the detection window were included in the study. The mean baseline NTHR was 59.6 ± 8.0 beats/min. During the follow-up period of 60.4 ± 21.8 months, 88 (16.5%) patients experienced cardiovascular mortality. After considering potential confounders, a linear association was observed. Each 1 beat/min increase in NTHR was associated with a 7.8%, 10.1%, and 5.7% increase in the risk of cardiovascular mortality in the total population, patients with heart failure, and patients without heart failure, respectively. CONCLUSION Continuous monitoring of NTHR may identify patients at high risk of cardiovascular mortality in a timely manner, with the potential for "preemptive" action. TRIAL REGISTRATION No. ChiCTR-ONRC-13003695.
Collapse
Affiliation(s)
- Jiang Jiang
- State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xuerong Sun
- Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
| | - Ruohan Chen
- State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yangang Su
- Department of Cardiology, Cardiology, Shanghai Institute of Cardiovascular Diseases, Fudan University, Shanghai, China
| | - Wei Xu
- Department of Cardiology, Nanjing Drum Tower Hospital, Nanjing, China
| | - Chendi Cheng
- Department of Cardiovascular Medicine, the Second Xiangya Hospital of Central South University, Changsha, China.
| | - Shu Zhang
- State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| |
Collapse
|
6
|
Hindricks G, Theuns DA, Bar-Lev D, Anguera I, Ayala Paredes FA, Arnold M, Geller JC, Merkely B, Dyrda KM, Perings C, Maglia G, Ploux S, Meyhöfer J, Blomström-Lundqvist C, Karjalainen P, Liang Y, Diemberger I, Wranicz JK, Barr C, Quartieri F, Timmel T, Bollmann A. Ability to remotely monitor atrial high-rate episodes using a single-chamber implantable cardioverter-defibrillator with a floating atrial sensing dipole. Europace 2023; 25:euad061. [PMID: 37038759 PMCID: PMC10227664 DOI: 10.1093/europace/euad061] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 12/06/2022] [Indexed: 04/12/2023] Open
Abstract
AIMS To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.
Collapse
Affiliation(s)
- Gerhard Hindricks
- Department of Electrophysiology, Heart Centre Leipzig and Leipzig Heart Institute, Strümpellstrasse 39, 04289 Leipzig, Germany
| | - Dominic A Theuns
- Erasmus University Medical Center,‘s-Gravendijkwal 230, 3015 GD Rotterdam, TheNetherlands
| | - David Bar-Lev
- Chaim Sheba Medical Center,52621 Tel Hashomer, Israel
| | - Ignasi Anguera
- Arrhythmia Unit, Heart Diseases Institute, Bellvitge Biomedical Research Institute (IDIBELL), Bellvitge University Hospital, Feixa Llarga, 08907 L'Hospitalet, Barcelona, Spain
| | | | - Martin Arnold
- Department of Cardiology, Friedrich-Alexander-Universität Erlangen-Nuremberg, Ulmenweg 18, 91054 Erlangen, Germany
| | - J Christoph Geller
- Zentralklinik Bad Berka GmbH,Robert-Koch-Allee 9, 99437 Bad Berka, Germany
| | - Béla Merkely
- Semmelweis Medical University, Városmajorutca 68, 1122 Budapest, Hungary
| | - Katia Marjolaine Dyrda
- Montreal Heart Institute affiliated with Université de Montréal, 5000, rue Belanger, H1T 1C8 Montréal, Québec, Canada
| | | | - Giampiero Maglia
- Azienda Ospedaliera Pugliese Ciaccio, Via Vinicio Cortese 25, 88100 Catanzaro, Italia
| | - Sylvain Ploux
- Hôpital Haut Lévêque (CHU), 1 avenue de Magellan, 33600 Pessac Cedex, France
| | - Jürgen Meyhöfer
- Maria Heimsuchung—Caritas-Klinik Pankow,Breite Str. 46/47, 13187 Berlin, Germany
| | - Carina Blomström-Lundqvist
- Department of Cardiology, School of Medical Sciences, Faculty of Medicine and Health, Örebro University, SE-701 82 Örebro, Sweden
- Department of Medical Science and Cardiology, Uppsala University, S-751 85 Uppsala, Sweden
| | - Pasi Karjalainen
- Satakunta Central Hospital, Sydänyksikkö, Sairaalantie 3, 28500 Pori, Finland
| | - Yanchun Liang
- General Hospital of Northern Theater Command, No. 83 Wenhua Road, Shenhe District, 110016 Shenyang, China
| | - Igor Diemberger
- Department of Experimental, Diagnostic and Specialty Medicine, Institute of Cardiology, University of Bologna, Via Massarenti 9, 40138 Bologna, Italia
| | - Jerzy Krzysztof Wranicz
- Department of Electrocardiology, Medical University of Lodz, Ul. Pomorska 251, 92-213 Łódź, Poland
| | - Craig Barr
- Russells Hall Hospital, Pensett Road, DY1 2HQ Dudley, UK
| | - Fabio Quartieri
- Arcispedale Santa Maria Nuova, Viale Risorgimento 80, 42123 Reggio Emilia, Italia
| | - Tobias Timmel
- Biotronik SE & Co. KG,Woermannkehre 1, 12359 Berlin, Germany
| | | |
Collapse
|
7
|
O'Connor M, Kolb C, Klein N, Rauwolf T, Kuster S, Kääb S, Tilz RR, Bänsch D, Ince H, Belke R, Hauser T, Rietsch K, Krämer JF, Wessel N, Lennerz C. REACT DX registry: Real world REACTion to atrial high rate episodes detected in implantable cardioverter-defibrillator recipients with a DX lead. Technol Health Care 2023; 31:735-746. [PMID: 36442163 DOI: 10.3233/thc-220432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
BACKGROUND Atrial fibrillation (AF) is associated with significant morbidity and is predicted by atrial high rate events. The early detection of AF is paramount to timely interventions to reduce the morbidity of AF. The DX ICD system combined with Home Monitoring® allows for continuous atrial rhythm monitoring without the need for a dedicated atrial lead. OBJECTIVE To establish the reaction to and timing of reactions to the detection of atrial high rate episodes (AHRE). METHODS A prospective cohort of DX ICD systems was followed up and the response to AHREs was collected and evaluated. RESULTS A total of 234 patients were enrolled; an AHRE ⩾ 6 min was detected in 13.7% of patients (n= 32) within a mean follow-up duration of 16 months. A high rate of oral anticoagulation (OAC) prescription was seen with the detection of AHREs in patients with a not-low risk CHA2DS2-VASc score. There was a delay in this prescription highlighting the potential to improve the timeliness of patient care in this group of patients. CONCLUSIONS The DX ICD system provides rapid and ongoing atrial rhythm monitoring such that physicians are rapidly aware of AHRE without the need for a dedicated atrial lead, but local protocols are needed to improve the response time of anti-coagulation prescription.
Collapse
Affiliation(s)
- Matthew O'Connor
- German Heart Center Munich, Department of Electrophysiology, Technical University of Munich, Munich, Germany
- The Royal Brompton and Harefield NHS Trust, Department of Electrophysiology, London, UK
| | - Christof Kolb
- German Heart Center Munich, Department of Electrophysiology, Technical University of Munich, Munich, Germany
| | - Norbert Klein
- Department of Cardiology, Angiology and Internal Intensive-Care Medicine, Klinikum St. Georg gGmbH, Leipzig, Germany
| | - Thomas Rauwolf
- Internal Medicine/Cardiology and Angiology, Magdeburg University, Magdeburg, Germany
| | - Stefan Kuster
- Department of Internal Medicine, Cardiology, DRK Hospital Mölln-Ratzeburg, Ratzeburg, Germany
| | - Stefan Kääb
- Department of Medicine 1, University Hospital, LMU Munich, Munich, Germany
- German Heart Center Munich, Department of Electrophysiology, Technical University of Munich, Munich, Germany
| | - Roland Richard Tilz
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein (UKSH), Lübeck, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| | - Dietmar Bänsch
- Clinic for Electrophysiology, KMG Klinikum, Güstrow, Germany
| | - Hüseyin Ince
- Department of Cardiology, Rostock University Medical Center, Rostock, Germany
| | - Roberto Belke
- BIOTRONIK, Berlin, Germany
- German Heart Center Munich, Department of Electrophysiology, Technical University of Munich, Munich, Germany
| | | | | | - Jan F Krämer
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Niels Wessel
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
- German Heart Center Munich, Department of Electrophysiology, Technical University of Munich, Munich, Germany
| | - Carsten Lennerz
- German Heart Center Munich, Department of Electrophysiology, Technical University of Munich, Munich, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Munich Heart Alliance, Munich, Germany
| |
Collapse
|
8
|
Carinci V, Ziacchi M, Iori M, De Maria E, Bolognesi MG, Zardini M, Calvi V, Allocca G, Ammendola E, Boggian G, Saporito D, Giorgi D, Statuto G, Giacopelli D, Grassini D, Biffi M. Incremental value of atrial sensing in the diagnosis of ICD recordings: findings from the THINGS registry. J Cardiovasc Med (Hagerstown) 2023; 24:62-64. [PMID: 36219152 DOI: 10.2459/jcm.0000000000001382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
| | | | | | | | | | | | - Valeria Calvi
- Azienda O.U. Policlinico G. Rodolico - San Marco, Catania
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
D’Onofrio A, Marini M, Rovaris G, Zanotto G, Calvi V, Iacopino S, Biffi M, Solimene F, Della Bella P, Caravati F, Pisanò EC, Amellone C, D’Alterio G, Pedretti S, Santobuono VE, Russo AD, Nicolis D, De Salvia A, Baroni M, Quartieri F, Manzo M, Rapacciuolo A, Saporito D, Maines M, Marras E, Bontempi L, Morani G, Giacopelli D, Gargaro A, Giammaria M. Prognostic significance of remotely monitored nocturnal heart rate in heart failure patients with reduced ejection fraction. Heart Rhythm 2022. [DOI: 10.1016/j.hrthm.2022.10.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
10
|
Gwag HB, Kim HR, Park SJ, Kim J, Chung TW, Choi JH, Kim JY, Park KM, On YK, Kim JS. The efficacy of single-lead implantable cardioverter-defibrillator with atrial sensing dipole to detect atrial fibrillation and to reduce inappropriate therapy according to atrial sensing ON or OFF: Rationale and design of the SMART-CONTROL study, a prospective multicenter randomized trial. Am Heart J 2022; 251:25-31. [PMID: 35568193 DOI: 10.1016/j.ahj.2022.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 04/30/2022] [Accepted: 05/04/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND Few studies have compared the efficacy of single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (VDD-ICD) and conventional single-chamber ICD from the aspect of atrial fibrillation (AF) detection or inappropriate ICD therapy reduction. In the SMART-CONTROL trial (NCT03932604), we primarily aim to investigate whether the atrial sensing capability of VDD-ICD is useful in AF detection and inappropriate therapy reduction by randomly activating or deactivating the atrial sensing function. METHODS AND DESIGN This study was designed as a prospective, multicenter, open-label, randomized trial to enroll 640 patients with no history of clinical AF or rhythm control for AF within 1 year who were undergoing the implantation of VDD-ICD system. Patients are assigned randomly to atrial sensing "ON" or "OFF" group, with crossover allowed during follow-up. The coprimary outcomes are the incidence of AF detection and inappropriate ICD therapy over a 2-year follow-up period. The secondary outcomes include non-AF atrial tachyarrhythmia, ventricular tachyarrhythmia with or without ICD therapy, thromboembolic events, bleeding, heart failure hospitalization, mortality, a composite of adverse cardiovascular events, and long-term atrial sensing stability or variability. CONCLUSION We expect that this trial can evaluate the efficacy of a single-lead ICD system on various clinical outcomes including AF detection and inappropriate therapy reduction, and ultimately provide guidance to selection of ICD system.
Collapse
Affiliation(s)
- Hye Bin Gwag
- Division of Cardiology, Department of Internal Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Republic of Korea
| | - Hye Ree Kim
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Seung-Jung Park
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
| | - Juwon Kim
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Tae Wan Chung
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Ji-Hoon Choi
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Ju Youn Kim
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Kyoung-Min Park
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Young Keun On
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - June Soo Kim
- Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| |
Collapse
|
11
|
Pung X, Hong DZ, Ho TY, Shen X, Tan PT, Yeo C, Tan VH. The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new-onset atrial high-rate episodes or subclinical atrial fibrillation: A systematic review and meta-analysis. J Arrhythm 2022; 38:177-186. [PMID: 35387136 PMCID: PMC8977580 DOI: 10.1002/joa3.12675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 12/14/2021] [Accepted: 01/03/2022] [Indexed: 11/10/2022] Open
Abstract
This meta-analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD-ICD) recipients in particular diagnosing new-onset atrial high-rate episodes (AHREs) defined as rate threshold of 200 beats per minute, or subclinical atrial fibrillation (SCAF) defined as device-detected AF without symptoms. We comprehensively searched PubMed, Embase, and ClinicalTrials.gov. Studies comparing contemporary single- and dual-chamber ICD (VVI-/DDD-ICD) versus VDD-ICD were included. Restricted maximum likelihood method for random effect model and Mantel-Haenszel method for fixed effect model were used to estimate the effect size of new-onset AHREs, or SCAF detection in each group. Three prospective studies were identified and total of 991 participants were included. There were 330 (33.3%) in VDD-ICD and 661 (66.7%) in VVI-/DDD-ICD. Most (78%) participants were men. Median follow-up was from 365 days to 847 days. VDD-ICD has a higher likelihood of detecting AHREs or SCAF as compared to VVI-/DDD-ICD [(OR random effect : 2.6; 95% CI: 1.2, 5.8; p = .018); I-squared = 67.8%, p = .019]. This difference was more apparently seen in the comparison between VDD-ICD and VVI-ICD [(OR random effect: 3.8; 95% CI: 2.1, 6.6, p < .001), I-squared = 0.0%, p = .518]. The result is same as fixed effect. Rate of AHREs detection observed in VDD-ICD was not statistically different when compared to the only group with DDD-ICD from SENSE trial. In conclusion, this meta-analysis reveals that the use of floating atrial sensing dipole in VDD-ICD increases the detection of new-onset AHREs or SCAF when compared to VVI-ICD, with similar atrial sensing performance to DDD-ICD.
Collapse
Affiliation(s)
- Xuanming Pung
- Department of CardiologyChangi General HospitalSingapore CitySingapore
| | - Daniel Zhihao Hong
- Yong Loo Lin School of MedicineNational University of SingaporeSingapore CitySingapore
| | - Tzyy Yeou Ho
- Yong Loo Lin School of MedicineNational University of SingaporeSingapore CitySingapore
| | - Xiayan Shen
- Department of CardiologyChangi General HospitalSingapore CitySingapore
| | - Pei Ting Tan
- Health Services ResearchChangi General HospitalSingapore CitySingapore
| | - Colin Yeo
- Department of CardiologyChangi General HospitalSingapore CitySingapore
| | - Vern Hsen Tan
- Department of CardiologyChangi General HospitalSingapore CitySingapore
| |
Collapse
|
12
|
Hsu JC, Hesselson AB, Liang JJ, Mountantonakis S, David GT, Costea A. Atrial fibrillation associated with heart failure treated by a 2-lead CRT-DX system (BIO-AffectDX): Study design and clinical protocol. Heart Rhythm O2 2022; 2:642-650. [PMID: 34988510 PMCID: PMC8703153 DOI: 10.1016/j.hroo.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background Evidence to support use of cardiac resynchronization therapy (CRT) among patients with both heart failure (HF) and atrial fibrillation (AF) is largely limited to retrospective or post hoc subanalyses. Data from a prospectively enrolled and contemporary cohort are needed. Objective We aim to better characterize the changes from baseline in HF patients with concomitant AF subsequently implanted with a 2-lead CRT-DX system capable of sensing in the atrium, aggregating diagnostics, and delivering CRT therapy. The primary objective of this study is to evaluate the percentage of all HF subjects with an improvement in a clinical composite score from pre-CRT implant to 12 months. Methods The study is a US-based, prospective, observational multicenter clinical trial conducted at up to 50 sites and enrolling approximately 400 subjects with a follow-up period of 1 year. Multiple subject assessments, atrial rhythm status, and device interrogation will be collected at follow-up visits occurring at 3, 6, and 12 months postimplant. Results A Clinical Events Committee will adjudicate subject HF events, arrhythmia events, death events, and all device-classified ventricular tachycardia and ventricular fibrillation episodes with treatment that are collected throughout the follow-up period. Their decisions are based on independent physician review of the data from sites and device interrogation. Conclusion The BIO-AffectDX study aims to provide further insight into the expected outcomes from CRT treatment in patients with HF and AF.
Collapse
Affiliation(s)
- Jonathan C Hsu
- Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California, San Diego, La Jolla, California
| | - Aaron B Hesselson
- University of Kentucky Gill Heart & Vascular Institute, Lexington, Kentucky
| | - Jackson J Liang
- Electrophysiology, Division of Cardiology, Internal Medicine, University of Michigan, Ann Arbor, Michigan
| | - Stavros Mountantonakis
- Division of Cardiac Electrophysiology, Lenox Hill Hospital, Northwell Health, New York, New York
| | | | - Alexandru Costea
- Clinical Cardiac Electrophysiology at University of Cincinnati Medical Center, Cincinnati, Ohio
| |
Collapse
|
13
|
Rapacciuolo A, Iacopino S, D'Onofrio A, Curnis A, Pisanò EC, Biffi M, Della Bella P, Dello Russo A, Caravati F, Zanotto G, Calvi V, Rovaris G, Senatore G, Nicolis D, Santamaria M, Giammaria M, Maglia G, Duca A, Ammirati G, Romano SA, Piacenti M, Celentano E, Bisignani G, Vaccaro P, Miracapillo G, Bertini M, Nigro G, Giacopelli D, Gargaro A, Bisceglia C. Cardiac resynchronization therapy defibrillators in patients with permanent atrial fibrillation. ESC Heart Fail 2021; 8:5204-5212. [PMID: 34514741 PMCID: PMC8712818 DOI: 10.1002/ehf2.13599] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 07/22/2021] [Accepted: 08/19/2021] [Indexed: 11/16/2022] Open
Abstract
Aims There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation. Methods and results We retrospectively analysed remote monitoring data from 1141 CRT defibrillators. Propensity score with inverse‐probability weighting method was used to balance AF and sinus rhythm (SR) groups. Analysis endpoints included total mortality, appropriate defibrillation shocks, and CRT percentage. There were 229 patients (20.1%) in the AF group and 912 patients (79.9%) in the SR group. Compared with SR patients, AF patients were older (median age, 77 vs. 72 years, P < 0.001), more frequently male (82.5% vs. 75.5%, P = 0.02), and had higher heart rate (75.7 vs. 71.0 b.p.m., P < 0.001). Of the 229 AF patients, 162 (70.7%) received suboptimal CRT (<98%) and 67 (29.3%) had adequate CRT (≥98%). During a median follow‐up of 24 months, total mortality did not differ between AF and SR groups (propensity‐score‐weighted hazard ratio, HR 1.32 [95% confidence interval, 0.82–2.15], P = 0.25). The risk of appropriate shocks was significantly higher in the AF group with <98% CRT than in the SR group (weighted‐HR, 1.99 [1.21–3.26], P = 0.006) and was similar in the AF group with ≥98% CRT versus the SR group (1.29 [0.66–2.53], P = 0.45). During follow‐up, sinus rhythm was recovered in 23 patients in the AF group (10%) after a median time of 106 (42–256) days. The rate of sinus rhythm recovery in the AF group was 4.5 (95% CI, 2.8–6.7) per 100 patient‐years; the rate of permanent AF occurrence in the SR group was 2.5 (95% CI, 1.9–3.3) per 100 patient‐years. Conclusions Although mortality was similar across patient groups, patients with permanent AF and suboptimal CRT had twofold higher risk of appropriate shocks than SR patients or AF patients with CRT ≥ 98%.
Collapse
Affiliation(s)
- Antonio Rapacciuolo
- Department of Advanced Biomedical Sciences, Federico II University of Naples, Corso Umberto I, 40, Naples, 80138, Italy
| | | | | | | | | | - Mauro Biffi
- Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | | | | | | | | | - Valeria Calvi
- Policlinico G. Rodolico, Az. O.U. Policlinico - V. Emanuele, Catania, Italy
| | | | | | | | | | | | | | - Antonio Duca
- IRCCS Neurolesi-Ospedale Piemonte, Messina, Italy
| | - Giuseppe Ammirati
- Department of Advanced Biomedical Sciences, Federico II University of Naples, Corso Umberto I, 40, Naples, 80138, Italy
| | | | | | | | | | - Paola Vaccaro
- AOR Villa Sofia-Cervello P.O. Cervello, Palermo, Italy
| | | | | | - Gerardo Nigro
- University of Campania "Luigi Vanvitelli," Monaldi Hospital, Naples, Italy
| | - Daniele Giacopelli
- Biotronik Italia S.p.a., Vimodrone, Italy.,University of Padova, Padova, Italy
| | | | | |
Collapse
|
14
|
Long-term evaluation of sensing variability of a floating atrial dipole in a single‑lead defibrillator: The mechanistic basis of long-term stability of amplified atrial electrogram. Int J Cardiol 2021; 336:67-72. [PMID: 33992702 DOI: 10.1016/j.ijcard.2021.05.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 04/25/2021] [Accepted: 05/10/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND A single‑lead implantable cardioverter-defibrillator (ICD) with a floating atrial dipole has been developed to enhance the diagnostic capability of atrial arrhythmias and to facilitate adjudication of arrhythmic events without the additional effort required for atrial lead insertion. However, there have been concerns about the long-term reliability of atrial sensing. METHODS We enrolled patients with the single-chamber ICD with atrial-sensing electrodes from 4 tertiary university hospitals in Korea. Minimal, maximal, and mean P wave amplitudes were collected at 3-6 months, 6-12 months, and 12-24 months after implantation. The difference between the minimal and maximal sensing amplitudes was calculated as an indicator of the variability of atrial sensing, while the atrial sensing stability was assessed using the mean amplitude. RESULTS A total of 86 patients were included for analysis. The variability of atrial sensing amplitudes significantly decreased at 12-24 months compared to 3-6 months (p = 0.01), while mean atrial amplitudes were stable throughout the mean follow-up duration of 17.4 months. Nine patients (10.5%) experienced inappropriate ICD therapy mostly due to misclassification of supraventricular tachycardia. CONCLUSIONS Under the hypothesis that sensing stability can be guaranteed as the variability decreases with time, we suggest that the concern about long-term sensing stability of a floating dipole can be abated with an ICD that has been implanted for over 2 years.
Collapse
|
15
|
Vamos M, Nemeth M, Balazs T, Zima E, Duray GZ. Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice. Trends Cardiovasc Med 2021; 32:84-89. [PMID: 33482321 DOI: 10.1016/j.tcm.2021.01.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 01/12/2021] [Accepted: 01/14/2021] [Indexed: 01/30/2023]
Abstract
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed. Besides all of the potential benefits, the necessity of a reliable and stable atrial sensing via the floating dipole could be the main concern against the use of this lead type. In the current generation of DX devices, the specially filtered atrial signal seems to be high enough and stable over time, which is crucial in the early detection of atrial arrhythmias, discrimination between different forms of tachycardias in order to prevent inappropriate ICD therapy, and achieving an optimal atrioventricular and interventricular synchrony in patients with a two-lead CRT-DX system. The present review summarizes the benefits and potential drawbacks of the DX ICD systems based on the available literature, furthermore, proposes an evidence-based algorithm of ICD type selection.
Collapse
Affiliation(s)
- Mate Vamos
- Department of Internal Medicine, Cardiac Electrophysiology Division, University of Szeged, Semmelweis u. 8., 6725 Szeged, Szeged, Hungary.
| | | | | | - Endre Zima
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Gabor Zoltan Duray
- Department of Cardiology, Medical Centre, Hungarian Defense Forces, Budapest, Hungary
| |
Collapse
|
16
|
Baalman SWE, Mittal S, Boersma LVA, Perschbacher D, Brisben AJ, Mahajan D, de Groot JR, Knops RE. Real-world performance of the atrial fibrillation monitor in patients with a subcutaneous ICD. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020; 43:1467-1475. [PMID: 32662101 PMCID: PMC7754353 DOI: 10.1111/pace.14010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 12/19/2022]
Abstract
Introduction The third‐generation subcutaneous implantable cardioverter‐defibrillator (S‐ICD) (EMBLEM™ A219, Boston Scientific) contains a new diagnostic tool to detect atrial fibrillation (AF) in S‐ICD patients, without the use of an intracardiac lead. This is the first study to evaluate the performance of the S‐ICD AF monitor (AFM). Methods The AFM algorithm analyzes a subcutaneous signal for the presence of AF, similar to the signals collected by implantable and wearable diagnostic devices. The AFM algorithm combines heart rate (HR) scatter analysis with an HR histogram. The algorithm was tested against publicly available electrocardiogram databases (simulated performance). Real‐world performance of the algorithm was evaluated by using the S‐ICD LATITUDE remote monitoring (RM) database. Results The simulated performance of the AFM algorithm resulted in a sensitivity of 95.0%, specificity of 100.0%, and positive predictive value (PPV) of 100.0%. To evaluate the real‐world performance of the AFM, 7744 S‐ICD devices were followed for up to 30 months by RM, whereof 99.5% had the AFM enabled. A total of 387 AF episodes were randomly chosen for adjudication, resulting in a PPV of 67.7%. The main cause of misclassification was atrial and ventricular ectopy. Conclusion The AFM exhibited a very high sensitivity and specificity in a simulated setting, designed to maximize PPV in order to minimize the clinical burden of reviewing falsely detected AF events. The real‐world performance of the AFM, enabled in 99.5% of S‐ICD patients, is a PPV of 67.7%.
Collapse
Affiliation(s)
- Sarah W E Baalman
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Suneet Mittal
- The Snyder Center for Comprehensive Atrial Fibrillation at the Valley Health System, Ridgewood, New Jersey
| | - Lucas V A Boersma
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.,St. Antonius Hospital, Nieuwegein, The Netherlands
| | | | | | | | - Joris R de Groot
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Reinoud E Knops
- Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
17
|
Shaik NA, Drucker M, Pierce C, Duray GZ, Gillett S, Miller C, Harrell C, Thomas G. Novel two-lead cardiac resynchronization therapy system provides equivalent CRT responses with less complications than a conventional three-lead system: Results from the QP ExCELs lead registry. J Cardiovasc Electrophysiol 2020; 31:1784-1792. [PMID: 32412126 PMCID: PMC7496977 DOI: 10.1111/jce.14552] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/05/2020] [Accepted: 05/11/2020] [Indexed: 01/20/2023]
Abstract
Introduction The novel two‐lead cardiac resynchronization therapy (CRT)‐DX system utilizes a floating atrial dipole on the implantable cardioverter‐defibrillator lead, and when implanted with a left ventricular (LV) lead, offers a two‐lead CRT system with AV synchrony. This study compared complication rates and CRT response among subjects implanted with a two‐lead CRT‐DX system to those subjects implanted with a standard three‐lead CRT‐D system. Methods and Results A total of 240 subjects from the Sentus QP—Extended CRT Evaluation with Quadripolar Left Ventricular Leads postapproval study were selected to identify 120 matched pairs based on similar demographic characteristics using a Greedy algorithm. The complication‐free rate was evaluated as the primary endpoint. All‐cause mortality, heart failure hospitalizations, device diagnostic data, New York Heart Association (NYHA) class improvement, and defibrillator therapy were evaluated from clinical data, in‐office interrogations, and remote monitoring throughout the follow‐up period. Complication‐free survival favored the CRT‐DX group with 92.5% without a major complication compared to 85.0% in the CRT‐D cohort (P = .0495; 95% confidence interval: 0.1%‐14.9%) over a mean follow‐up of 1.3 and 1.4 years, respectively. Incidence of all‐cause mortality, heart failure hospitalizations, NYHA changes at 6 months postimplant, and percent of LV pacing during CRT therapy were similar in both device cohorts. Inappropriate shocks were more frequent in the CRT‐D cohort with 5.8% of subjects receiving an inappropriate shock vs 0.8% in the CRT‐DX cohort. Conclusion The results of this subanalysis demonstrate that the CRT‐DX system can provide similar CRT responses and significantly fewer complications when compared to a similar cohort with a conventional three‐lead CRT‐D system.
Collapse
Affiliation(s)
- Naushad A Shaik
- Department of Cardiac Electrophysiology, Advent Health Orlando, Orlando, Florida
| | - Michael Drucker
- Department of Cardiac Electrophysiology, Novant Health Cardiology of Forsyth Medical Center, Winston-Salem, North Carolina
| | - Christopher Pierce
- Department of Cardiac Electrophysiology, Sanford Medical Center, Fargo, North Dakota
| | - Gabor Z Duray
- Department of Cardiology, Medical Centre, Hungarian Defense Forces, Budapest, Hungary
| | - Shane Gillett
- Clinical Studies Department, Biotronik, Inc, Lake Oswego, Oregon
| | - Crystal Miller
- Clinical Studies Department, Biotronik, Inc, Lake Oswego, Oregon
| | - Camden Harrell
- Clinical Studies Department, Biotronik, Inc, Lake Oswego, Oregon
| | - George Thomas
- Division of Cardiology, Weill Cornell Medical College, New York, New York
| |
Collapse
|