1
|
Thermal Effects on Dental Pulp during Laser-Assisted Bleaching Procedures with Diode Lasers in a Clinical Study. J Clin Med 2024; 13:2301. [PMID: 38673574 PMCID: PMC11050821 DOI: 10.3390/jcm13082301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 04/09/2024] [Accepted: 04/12/2024] [Indexed: 04/28/2024] Open
Abstract
Background In the current cosmetics industry, bleaching is often associated with lasers. However, such treatment also harbors risks. Tooth death is observed at pulpal temperature increases ≥5.6 °C. Therefore, it seems important to investigate the effects of using different lasers. The aim of this study was to determine pulpal temperature increases at different laser parameters during bleaching by modeling a realistic environment and to compare the temperature recording using a thermocouple and thermal camera. The authors assumed that there are laser settings for the lasers used at which the pulpal temperature increases are <5.6 °C and that the temperature recordings with thermocouples and thermal cameras differ only minimally. Methods Human teeth were used, which were extracted for dental reasons. During experiment, teeth were bleached conventionally and by laser activation at 940 nm, 445 nm, and 970 nm. The temperature in the pulp was recorded using thermocouples. In a second setup, longitudinally halved teeth were bleached, while the temperature in the pulp was recorded with a thermocouple and thermal camera. Descriptive statistics were used. The significance level is 0.05. Results In addition to conventional bleaching, temperature increases <5.6 °C were observed for bleaching at 940 nm 1.5 W, at 445 nm 0.3 W, and at 970 nm 0.5 W. For bleaching procedures using 940 nm 7 W, 940 nm 2 W, 445 nm 0.5 W, and 970 nm 1 W, the temperature increase was ≥5.6 °C. Significant differences (p < 0.05) were found in the maximum temperature increases (°C) between all groups. Temperature recordings using a thermocouple and thermal camera differed by about 2.3 °C. The working hypotheses were confirmed. Conclusion With laser bleaching, attention must be paid to the type of laser, its power, and the time in order to avoid excessive overheating of the dental pulp.
Collapse
|
2
|
Enamel changes of bleached teeth following application of an experimental combination of chitosan-bioactive glass. BMC Oral Health 2024; 24:445. [PMID: 38609921 PMCID: PMC11015582 DOI: 10.1186/s12903-024-04195-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 03/27/2024] [Indexed: 04/14/2024] Open
Abstract
BACKGROUND Considering the extensive use of bleaching agents and the occurrence of side effects such as enamel demineralization, this study aimed to assess the enamel changes of bleached teeth following the experimental application of chitosan-bioactive glass (CH-BG). METHODS In this in vitro study, CH-BG (containing 66% BG) was synthesized and characterized by Fourier-transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD). Thirty sound human premolars were bleached with 40% hydrogen peroxide, and the weight% of calcium and phosphorus elements of the buccal enamel surface was quantified before and after bleaching by scanning electron microscopy/ energy-dispersive X-ray spectroscopy (SEM, EDX). Depending on the surface treatment of the enamel surface, the specimens were divided into three groups (n = 10): control (no treatment), MI Paste (MI), and CH-BG. Then the specimens were stored in artificial saliva for 14 days. The SEM/EDX analyses were performed again on the enamel surface. Data were analyzed by one-way ANOVA and Tukey's test and a p-value of < 0.05 was considered statistically significant. RESULTS In all groups, the weight% of calcium and phosphorus elements of enamel decreased after bleaching; this reduction was significant for phosphorus (p < 0.05) and insignificant for calcium (p > 0.05). After 14 days of remineralization, the weight% of both calcium and phosphorus elements was significantly higher compared to their bleached counterparts in both MI and CH-BG groups (p < 0.05). Following the remineralization process, the difference between MI and CH-BG groups was not significant (p > 0.05) but both had a significant difference with the control group in this regard (p < 0.05). CONCLUSIONS The synthesized CH-BG compound showed an efficacy comparable to that of MI Paste for enamel remineralization of bleached teeth.
Collapse
|
3
|
An In Vitro Study on the Effects of Hydrogen Peroxide-Based Bleaching Agents on Enamel: Field Emission Scanning Electron Microscopy (FESEM) With Energy Dispersive Spectroscopy (EDS) Evaluation. Cureus 2024; 16:e58318. [PMID: 38752025 PMCID: PMC11095582 DOI: 10.7759/cureus.58318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/09/2024] [Indexed: 05/18/2024] Open
Abstract
Aim and objective The aim of the present in vitro study is to evaluate the morphological and elemental alterations in enamel following bleaching with hydrogen peroxide-based bleaching agents of different concentrations and pH values when exposed to different treatment times. Materials and method Twenty extracted maxillary central incisors were selected for the study. Tooth samples were prepared by sectioning the tooth cervico-incisally into two halves. The teeth were divided into different groups based on the bleaching protocol and bleaching agent applied: Group IA, Group IB, Group IIA, and Group IIB. Group IA received a 35% hydrogen peroxide-based bleaching agent of pH 6 for 10 minutes with light application. Group IB received a 35% hydrogen peroxide-based bleaching agent of pH 6 for 30 minutes with light activation. Group IIA received a 40% hydrogen peroxide-based bleaching agent of pH 8.5 for 10 minutes with chemical activation. Group IIB received a 40% hydrogen peroxide-based bleaching agent of pH 8.5 for 30 minutes with chemical activation. The morphology of the enamel before and after the application of the bleaching agent was evaluated using field emission scanning electron microscopy. The elemental analysis of enamel between the control and test samples was done with the help of energy dispersive spectroscopy. Results Paired t-test was used to analyze the data obtained from the study. The test samples showed erosive alterations in enamel surface morphology and also a decrease in the concentration of minerals when compared to the corresponding control groups. Conclusions The present study evidences the erosive potential of hydrogen peroxide-based bleaching agents. It can be concluded that bleaching agents containing high concentrations of hydrogen peroxide with acidic pH can cause mineral loss and surface erosion of enamel which is extremely detrimental to the tooth integrity.
Collapse
|
4
|
Analysis of Calcium and Phosphate Ion Extraction From Dental Enamel by Bleaching Gels Using Ion Chromatography, Micro-CT, and SEM. Oper Dent 2024; 49:157-165. [PMID: 38349817 DOI: 10.2341/23-026-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/12/2023] [Indexed: 02/15/2024]
Abstract
OBJECTIVES To evaluate the volume and depth of enamel loss promoted by 37.5% and 7.5% hydrogen peroxide (HP) gels, and quantify the loss of calcium (Ca) and phosphate (P) ions by using ion chromatography (IC) analysis after bleaching. METHODS Sixty bovine enamel specimens were randomly divided into three groups: Control - no bleaching gel; HP37.5%, application of HP 37.5% for 45 minutes for 14 days; and HP7.5%, application of HP 7.5% for 3 applications of 8 minutes. The surface analysis (n=5) was performed using a scanning electron microscope (SEM) and dispersive energy system (EDS) to calcium and phosphorus dosage. The micro-CT was used for the enamel loss analysis (n=5). IC was used to analyze extracted Ca and P (n=10). Data were analyzed by one-way ANOVA and two-way repeated measures ANOVA, followed by Tukey and Dunnett's tests (α=0.05). RESULTS Significantly higher volume and depth of enamel loss were found for bleached groups compared with the control group. HP7.5% had significantly higher enamel change than HP37.5%. SEM showed higher enamel porosity for HP37.5% and HP7.5% compared to control. The IC demonstrated a significant increase of Ca incorporated into the gel, however, only HP7.5% had a higher P presence than the control group. The HP7.5% showed higher Ca and P ion exchange than HP37.5% (p<0.001). CONCLUSION HP37.5% and HP7.5%, caused enamel mineral changes compared with the control group. The IC method was demonstrated to be an effective methodology for detecting enamel mineral loss by the bleaching gel.
Collapse
|
5
|
Comparative evaluation of remineralization potential of four different remineralization agents on human enamel: An in vitro study. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:29-35. [PMID: 38389734 PMCID: PMC10880471 DOI: 10.4103/jcde.jcde_113_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Revised: 10/17/2023] [Accepted: 10/26/2023] [Indexed: 02/24/2024]
Abstract
Aim The study aimed to assess the remineralizing potential of four different commercially available agents using a Scanning Electron Microscope (SEM), energy dispersive X-ray (EDX) analysis, and Vickers Microhardness (VMH) Test. Materials and Methods Forty-four specimens (n = 11 per group) were prepared from extracted teeth. A window of 6 mm × 4 mm was made on all the specimens that represented three zones, namely, sound enamel, demineralized enamel, and remineralized enamel. The zone for demineralized enamel was subjected to four different remineralizing agents; casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF), tricalcium phosphate fluoride (TCP-F), calcium sucrose phosphate (CSP), and self-assembling peptide (P11-4). Remineralization (REM) was assessed using VMH; the structural changes were assessed using SEM that was analyzed using EDX analysis. The specimens were subjected to a newer regimen of demineralization. One-way ANOVA followed by post hoc Tukey test was used with a level of significance at P ≤ 0.05. Results There were no significant differences in VMH between the groups for sound enamel (P = 0.472) and demineralized enamel (P = 0.116). VMH was statistically significantly more for P11-4 and the least for CPP-ACPF (P = 0.011). A post hoc analysis revealed higher VMH for P11-4 compared to CPP-ACPF (P = 0.014) and TCP-F (P = 0.035). SEM showed a homogeneous layer of minerals for all groups except CPP-ACPF. TCP-F reported a higher degree of REM, followed by P11-4 as assessed using EDX analysis. Conclusion Self-assembling peptide (P11-4) exhibited a higher degree of REM than other remineralizing agents followed by CSP.
Collapse
|
6
|
Effect of strontium fluorophosphate bioactive glass on color, microhardness and surface roughness of bleached enamel. Technol Health Care 2024; 32:285-292. [PMID: 37270825 DOI: 10.3233/thc-230074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
BACKGROUND Undesirable effects of tooth bleaching can alter the biomechanical properties of enamel. OBJECTIVE To determine the influence of strontium fluorophosphate bioactive glass (Sr-FPG) on color, microhardness and surface roughness of enamel bleached with 35% hydrogen peroxide. METHODS The labial enamel of 36 extracted intact human anterior teeth were divided into 3 groups (n= 12), group 1 (HP): bleaching with 35% hydrogen peroxide only, group 2 (Sr-HP): bleaching with Sr-FPG incorporated 35% hydrogen peroxide and group 3 (HP-SrFPG): bleaching with 35% hydrogen peroxide followed by remineralization with Sr-FPG. Four consecutive eight-minute applications of the bleaching gel were done twice in all the groups. Color change (ΔE), microhardness and surface roughness were evaluated at baseline, post-bleaching and post-remineralization using spectrophotometer, Vickers hardness tester and profilometric analysis respectively. RESULTS The mean ΔE among the groups was statistically similar (p> 0.05). Bleaching with HP significantly reduced microhardness (p< 0.05), whereas bleaching with Sr-HP and HP-SrFPG did not (p> 0.05). Post-bleaching microhardness in Sr-HP was significantly higher than HP-SrFPG (p< 0.05). An increased surface roughness was seen in Sr-HP bleached samples (p< 0.05). CONCLUSION The addition of Sr-FPG to hydrogen peroxide significantly improved enamel microhardness than its use post-bleaching. An increase in surface roughness was seen post-bleaching with HP and Sr-HP.
Collapse
|
7
|
Effect of the Teeth Whitening Procedure on the Mineral Composition of Oral Fluid. Dent J (Basel) 2023; 12:9. [PMID: 38248217 PMCID: PMC10814888 DOI: 10.3390/dj12010009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/19/2023] [Accepted: 12/28/2023] [Indexed: 01/23/2024] Open
Abstract
The basis of modern tooth whitening systems is the use of a whitening gel, which usually contains hydrogen peroxide or carbamide peroxide. The study included 81 patients aged 22 to 35 years with a tooth color A2 and a darker color on the Vita Classic scale. The purpose of our research was to identify a new approach to whitening teeth to improve safety and gentleness. To perform this, we assessed the effect of the tooth whitening procedure on the mineral composition of the oral fluid. A new approach to the teeth whitening procedure was to use a mouth retractor and a tool for aspirating the whitening gel, which we developed. Before the procedure, a protective film-forming aerosol, which included sodium ascorbate, was applied. After the tooth whitening procedure, the enamel was remineralized with a sealing liquid for 14 days. The concentrations of calcium and phosphorus in the oral fluid were determined using a spectrophotometer with a set of reagents (Human). The results obtained indicate that the new approach to the teeth whitening procedure contributed to less pronounced changes in the concentrations of calcium (+29.07, p < 0.001) and phosphorus (-14%, p < 0.001) in the oral fluid immediately after the procedure and in combination with the standard procedure for teeth whitening; immediately after this procedure, the calcium concentration increased by 74.4% (p < 0.001), and the phosphorus concentration decreased by 23.07% (p < 0.001). The use of remineralizing agents led to a faster recovery of the initial levels of calcium and phosphorus in the oral fluid.
Collapse
|
8
|
Chemical, morphological and microhardness analysis of coronary dentin submitted to internal bleaching with hydrogen peroxide and violet LED. Photodiagnosis Photodyn Ther 2023; 44:103862. [PMID: 37890812 DOI: 10.1016/j.pdpdt.2023.103862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/23/2023] [Accepted: 10/24/2023] [Indexed: 10/29/2023]
Abstract
BACKGROUND Violet LED has been used for internal bleaching, however its implications on coronary dentin composition are unclear. The present study aims to evaluate the effect of bleaching with violet LED, either associated with 35 % hydrogen peroxide or not, on microhardness, chemical composition, and morphological characteristics of coronal dentin. METHODS Thirty maxillary canines were selected to obtain 30 blocks of coronal dentin, distributed in 3 groups (n = 10): 35 % hydrogen peroxide (HP); violet LED (LED); HP 35 % + LED, (HP+LED). The chemical analysis was performed by FTIR and the morphological evaluation of the dentin structure by confocal laser scanning microscopy before (T0) and after treatment (T1). The microhardness analysis was performed by microdurometer after bleaching. The data were submitted to repeated measures ANOVA test (P> 0.05). RESULTS The intensity of the inorganic peaks decreased after bleaching for all groups (P = 0.003). There was an increase in the organic peak intensity after bleaching with HP, a decrease for LED, while HP+LED did not change the intensity (P = 0.044). Moreover, the inorganic/organic ratio decreased for HP (P = 0.022), while for LED and HP+LED there was no significant changes (P>0.05). HP and HP+LED showed lower microhardness values compared to LED (P< 0.05). Regarding morphological changes, an increase in the perimeter of the dentinal tubules was found for all groups, with the smallest increase being observed for LED. CONCLUSION HP bleaching decreased the chemical stability and microhardness of the coronal dentin, while the violet LED treatments had no significant impact on dentin stability. In all groups, there was an increase in exposure of the dentinal tubules after bleaching, which was less pronounced with the violet LED bleaching.
Collapse
|
9
|
In vitro bleaching efficacy of violet LED associated with 10% hydrogen peroxide and 10% carbamide peroxide. Photodiagnosis Photodyn Ther 2023; 44:103793. [PMID: 37689126 DOI: 10.1016/j.pdpdt.2023.103793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 09/11/2023]
Abstract
BACKGROUND This in vitro study evaluated the efficacy and the effect over the dental enamel surface of violet LED dental bleaching associated to different concentrations of carbamide and hydrogen peroxide. METHODS Human dental blocks (n = 100) were randomly distributed into 5 groups: 10% hydrogen peroxide (HP10), 10% carbamide peroxide (CP10), 10% hydrogen peroxide with violet LED (VHP10), 10% carbamide peroxide with violet LED (VCP10) and 35% hydrogen peroxide (HP35). The specimens were analyzed by Vickers microhardness test (n = 50) initially, immediately after and seven days after ending the bleaching protocol. For color analysis (n = 50), the specimens were evaluated for bleaching effectiveness (ΔE2000, ΔE1976) and whiteness index (ΔWID) with EasyShade spectrophotometer, before bleaching protocol and seven days after ending the bleaching protocol. The microhardness and color data were analyzed using one-way ANOVA with post-hoc Tukey test (α = 0.05). RESULTS The microhardness values showed difference among the investigated groups only immediately after the end of the dental bleaching (p < 0.05), with reduction for the groups HP35 (p < 0.01) and HP10 (p < 0.05), however the microhardness values were reestablished after seven days. Regarding the color changes, a difference between VHP10 and the others groups evaluated for ΔE2000 and ΔE1976 index was observed (p < 0.05). For ΔWID, there was no difference between the studied groups. CONCLUSIONS Violet LED associated with low concentration bleaching agents did not show a negative effect on dental enamel regarding the surface microhardness. All bleaching protocols were effective, therefore, perceptible to human eyes.
Collapse
|
10
|
Influence of bleaching gels formulated with nano-sized sodium trimetaphosphate and fluoride on the physicochemical, mechanical, and morphological properties of dental enamel. J Dent 2023; 139:104743. [PMID: 37839624 DOI: 10.1016/j.jdent.2023.104743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 10/02/2023] [Accepted: 10/12/2023] [Indexed: 10/17/2023] Open
Abstract
OBJECTIVES To evaluate in vitro the effects of sodium fluoride (F) and nano-sized sodium trimetaphosphate (TMPnano) added to a 35% hydrogen peroxide (H2O2) bleaching gel on the color alteration, enamel mechanical and morphological properties, and H2O2 transamelodentinal diffusion. MATERIALS AND METHODS Bovine enamel/dentin discs (n = 180) were divided according to the bleaching gel: 35% H2O2 (HP); 35% H2O2 + 0.1% F (HP/F); 35% H2O2 + 1% TMPnano (HP/TMPnano); 35% H2O2 + 0.1% F + 1% TMPnano (HP/F/TMPnano) and 35% H2O2 + 2% calcium gluconate (HP/Ca). The gels were applied 3 times by 40 min; once each 7-day. The Commission Internationale de l'Eclairage (CIE) L*a*b* total color alteration (ΔE), color alteration by CIEDE2000 (ΔE00), whitening index (ΔWID), surface (SH) and cross-sectional hardness (ΔKHN), surface roughness (Ra), and transamelodentinal diffusion were determined. Enamel surfaces were evaluated by Scanning Electron Microscopy (SEM) and X-ray Dispersive Energy (EDX). Data were submitted to ANOVA, followed by the Student-Newman-Keuls test (p <0.05). RESULTS ΔE, ΔE00, and ΔWID were similar among the gels that promoted a bleaching effect after treatment (p <0.001). Mineral loss (SH and ΔKHN), Ra, and H2O2 diffusion were lower for HP/F/TMPnano; the HP and HP/Ca groups presented the highest values (p <0.001). For SEM/EDX, surface changes were observed in all bleached groups, but less intense with TMPnano. CONCLUSIONS Gels containing F/TMPnano do not interfere with the bleaching effect and reduce enamel demineralization, roughness, H2O2 diffusion, and morphological changes. CLINICAL RELEVANCE Whitening gels containing F/TMPnano can be used as a new strategy to increase safety and maintain clinical performance.
Collapse
|
11
|
Assessment of the Remineralizing Potential of Biomimetic Materials on Early Artificial Caries Lesions after 28 Days: An In Vitro Study. Bioengineering (Basel) 2023; 10:bioengineering10040462. [PMID: 37106649 PMCID: PMC10135753 DOI: 10.3390/bioengineering10040462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/03/2023] [Accepted: 03/14/2023] [Indexed: 04/29/2023] Open
Abstract
This study aimed to evaluate the loss of mineral content in the enamel surface in early artificial lesions and to assess the remineralizing potential of different agents by means of SEM coupled with energy-dispersive X-ray analysis (EDX). The analysis was performed on the enamel of 36 molars divided into six equal groups, in which the experimental ones (3-6) were treated using remineralizing agents for a 28-day pH cycling protocol as follows: Group 1, sound enamel; Group 2, artificially demineralized enamel; Group 3, CPP-ACP treatment; Group 4, Zn-hydroxyapatite treatment; Group 5, NaF 5% treatment; and Group 6, F-ACP treatment. Surface morphologies and alterations in Ca/P ratio were evaluated using SEM-EDX and data underwent statistical analysis (p < 0.05). Compared with the sound enamel of Group 1, the SEM images of Group 2 clearly showed loss of integrity, minerals, and interprismatic substances. Groups 3-6 showed a structural reorganization of enamel prisms, interestingly comprising almost the entire enamel surface. Group 2 revealed highly significant differences of Ca/P ratios compared with other groups, while Groups 3-6 showed no differences with Group 1. In conclusion, all tested materials demonstrated a biomimetic ability in remineralizing lesions after 28 days of treatment.
Collapse
|
12
|
Efficacy of Endodontic Disinfection Protocols in an E. faecalis Biofilm Model-Using DAPI Staining and SEM. J Funct Biomater 2023; 14:jfb14040176. [PMID: 37103266 PMCID: PMC10145082 DOI: 10.3390/jfb14040176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 03/15/2023] [Accepted: 03/21/2023] [Indexed: 04/28/2023] Open
Abstract
The aim of this study was to investigate the antimicrobial efficacy of different disinfection protocols in a novel Enterococcus faecalis biofilm model based on a visualization method and to evaluate the potential alteration of dentinal surface. A total of 120 extracted human premolars were allocated to 6 groups with different irrigation protocols. The assessment of the effectiveness of each protocol and the alteration of dentinal surface were visualized by using SEM and fluorescence microscopy (DAPI). A dense E. faecalis biofilm with a penetration depth of 289 μm (medial part of the root canal) and 93 μm (apical part) validated that the biofilm model had been successfully implemented. A significant difference between the 3% NaOCl groups and all the other groups in both observed parts of the root canal (p < 0.05) was detected. However, the SEM analysis revealed that the dentinal surface in the 3% NaOCl groups was severely altered. The established biofilm model and the visualization method based on DAPI are appropriate for bacterial quantification and evaluation of the depth effect of different disinfection protocols in the root canal system. The combination of 3% NaOCl with 20% EDTA or MTAD with PUI allows the decontamination of deeper dentine zones within the root canal but simultaneously alters the dentinal surface.
Collapse
|
13
|
Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2403. [PMID: 36984283 PMCID: PMC10058876 DOI: 10.3390/ma16062403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/11/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
Lack of standardization of the retention phase has led to many studies of stability of movements and characteristic of retainers, disregarding the enamel repercussions of fixed retention on this phase. This study aimed to analyze different methods of enamel polishing after detachment of orthodontic retainers. Forty-five healthy premolars were divided into three groups according to the polishing bur after debonding, and four specimens without intervention were used as control. A 0.038 × 0.015 inches gold chain was bonded between the premolars and then removed. The adhesive remnant was removed with three types of burs according to the study groups (Group 1: white stone at high speed; Group 2: high-speed handpiece with a 30-blade tungsten carbide bur; Group 3: low-speed handpiece and a 30-blade tungsten bur). After debonding and polishing, all samples were analyzed with a confocal microscopy on surface roughness parameters: Sa: Arithmetic mean of the height of the surface. Rq: Square mean of the height of the surface and Sz: Maximum surface height. Mechanical tests were carried out to determine the bonding stress of the retention adhered to the teeth using an electromechanical testing machine. The adhesion stress was 8.23 MPa (±0.87). The quality of the refinement of the enamel after debonding is essential in order to preserve its integrity. The use of the 30-blade tungsten carbide bur provides a smooth enamel surface after polishing.
Collapse
|
14
|
Use of calcium-containing bioactive desensitizers in dental bleaching: A systematic review and meta-analysis. J Am Dent Assoc 2023; 154:245-259.e12. [PMID: 36717350 DOI: 10.1016/j.adaj.2022.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 10/26/2022] [Accepted: 11/28/2022] [Indexed: 01/30/2023]
Abstract
BACKGROUND Topical application of calcium-containing bioactive desensitizers (CBs) has been used to minimize bleaching-induced tooth sensitivity (TS). This study answered the research question "Is the risk of TS lower when CBs are used with dental bleaching in adults compared with bleaching without desensitizers?" TYPES OF STUDIES REVIEWED The authors included randomized clinical trials comparing topical CB application with a placebo or no intervention during bleaching. Searches for eligible articles were performed in MEDLINE via PubMed, Cochrane Library, Brazilian Library in Dentistry, Latin American and Caribbean Health Sciences Literature, Scopus, Web of Science, Embase, and gray literature without language and date restrictions and updated in September 2022. The risk of bias was evaluated using Risk of Bias Version 2.0. The authors conducted meta-analyses with the random-effects model. The authors assessed heterogeneity with the Cochrane Q test, I2 statistics, and prediction interval. The authors used the Grading of Recommendations Assessment, Development and Evaluation approach to assess the certainty of the evidence. RESULTS After database screening, 22 studies remained, with most at high risk of bias. No difference in the risk of TS was detected (risk ratio, 0.95; 95% CI, 0.90 to 1.01; P = .08, low certainty). In a visual analog scale, the intensity of TS (mean difference, -0.98; 95% CI, -1.36 to -0.60; P < .0001, very low certainty) was lower for the CB group. The color change was unaffected (P > .08). PRACTICAL IMPLICATIONS Although topical CB dental bleaching did not reduce the risk of TS and color change, these agents slightly reduced the TS intensity, but the certainty of the evidence is very low.
Collapse
|
15
|
Tooth Whitening with Hydroxyapatite: A Systematic Review. Dent J (Basel) 2023; 11:dj11020050. [PMID: 36826195 PMCID: PMC9955010 DOI: 10.3390/dj11020050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 02/06/2023] [Accepted: 02/09/2023] [Indexed: 02/16/2023] Open
Abstract
A steadily increasing public demand for whiter teeth has resulted in the development of new oral care products for home use. Hydroxyapatite (HAP) is a new ingredient to whiten teeth. This systematic review focuses on the evidence of whether HAP can effectively whiten teeth. A systematic search using the PICO approach and PRISMA guidelines was conducted using PubMed, Scopus, Web of Science, SciFinder, and Google Scholar as databases. All study designs (in vitro, in vivo) and publications in foreign language studies were included. Of the 279 study titles that the searches produced, 17 studies met the inclusion criteria. A new "Quality Assessment Tool For In Vitro Studies" (the QUIN Tool) was used to determine the risk of bias of the 13 studies conducted in vitro. Moreover, 12 out of 13 studies had a low risk of bias. The in vivo studies were assigned Cochrane-based GRADE scores. The results in vitro and in vivo were consistent in the direction of showing a statistically significant whitening of enamel. The evidence from in vitro studies is rated overall as having a low risk of bias. The evidence from in vivo clinical trials is supported by modest clinical evidence based on six preliminary clinical trials. It can be concluded that the regular use of hydroxyapatite-containing oral care products effectively whitens teeth, but more clinical trials are required to support the preliminary in vivo evidence.
Collapse
|
16
|
Effect of highly concentrated bleaching gels on enamel microhardness and superficial morphology, and the recovery action of four remineralizing agents. BMC Oral Health 2022; 22:645. [PMID: 36575416 PMCID: PMC9793581 DOI: 10.1186/s12903-022-02693-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 12/23/2022] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Dental bleaching is a common clinical practice. The aim of this study is to investigate the effect of 35% hydrogen peroxide (HP) bleaching gel on the morphology and microhardness of enamel, and to analyze the effect of four remineralizing agents. METHODS One hundred blocks were prepared. The enamel surfaces were bleached with 35% HP in one session. The specimens were divided into four remineralization treatment groups (n = 25). G1: Tooth Mousse, G2: Remin-Pro, G3: Colgate Pro-Relif, G4: Mirafluor. The remineralizing protocol was applied 3 min per day for one week. Vickers microhardness (HV) measurements and SEM observations were performed at baseline, after bleaching, and after remineralizing treatment in all groups. Statistical analyses were performed using the paired t-test and ANOVA. RESULTS After bleaching, SEM showed an increase of irregularities on the surface of the samples. Enamel microhardness decreased a mean of 47.7 HV, equivalent to a mean decrease of 18.3% (p < 0.05). After remineralization, the HV increased in all groups between 16 and 33% (p < 0.01), recovering the initial microhardness of enamel samples. SEM images revealed a higher quantity of superficial mineral deposits in groups 1 and 2 compared to the rest of the groups. CONCLUSIONS The application of remineralizing products generates a significant increase in enamel microhardness. Tooth Mousse-treated samples showed a greater microhardness recovery, followed by Remin Pro. The superficial morphology of the samples reflects the results obtained in the HV tests.
Collapse
|
17
|
The impact of remineralization agents on dental bleaching efficacy and mineral loss in bleached enamel. Eur J Oral Sci 2022; 130:e12905. [PMID: 36349560 DOI: 10.1111/eos.12905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 10/24/2022] [Indexed: 11/11/2022]
Abstract
This study evaluated the effect of remineralization agents on bleaching efficiency, enamel mineral changes, and post-bleaching color stability. A total of 112 enamel-dentin blocks were prepared from bovine teeth. Following initial color measurements, separate treatment regimens were carried out as follows: negative control (no treatment); positive control (bleaching only); bleaching, then NaF; bleaching + NaF (mix); bleaching, then CPP-ACPF; bleaching + CPP-ACPF (mix); bleaching, then nHAP+F; bleaching + nHAP+F (mix). Color measurements were repeated after immersion in distilled water for 7 days, and again after staining with coffee solution for 14 days. The CIELAB-based whiteness index was used to evaluate bleaching efficiency, and the CIEDE2000 color difference formula for color stability. Chemical investigation was performed using scanning electron microscopy with energy dispersive spectroscopy and X-ray diffraction analyses. The experimental groups showed significant increases in whiteness compared to the negative control, and the staining after bleaching did not result in statistically significant differences between the groups. Energy dispersive spectroscopic analysis revealed that bleaching protocols had no impact on elemental levels as well as the ratio of Ca/P. The combined use of bleaching agents with remineralization agents did not affect bleaching effectiveness but also did not provide an additional contribution.
Collapse
|
18
|
Effectiveness of violet LED dental bleaching compared to 35% hydrogen peroxide: An in vitro study. Photodiagnosis Photodyn Ther 2022; 40:102978. [PMID: 35728754 DOI: 10.1016/j.pdpdt.2022.102978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 05/23/2022] [Accepted: 06/17/2022] [Indexed: 12/14/2022]
Abstract
AIM This in vitro study assessed the efficacy and adverse effects of violet LED bleaching with or without bleaching agents. MATERIAL AND METHODS Dental blocks (n=40) were randomly distributed in 4 groups: violet LED (VL), 35% hydrogen peroxide (HP35), the association of hydrogen peroxide 35% with violet LED (VHP35) and the association of hydrogen peroxide 35% with blue LED (BHP35). Specimens were analyzed for Vickers microhardness initially, immediately after and seven days after ending bleaching protocol. The color analysis of the specimens was evaluated for bleaching effectiveness (ΔE2000, ΔE1976) and whiteness index (ΔWID) with EasyShade spectrophotometer, before bleaching protocol and seven days after ending bleaching protocol. The mineral composition of the enamel was evaluated by percentage of phosphorus and calcium on the enamel surface with energy dispersive spectroscopy (EDS). The color and the microhardness data were analyzed using one-way ANOVA with post-hoc Tukey (α=0.05). RESULTS The microhardness test showed a difference among the groups only immediately after the completion of the protocol, in which there was a reduction in the value for the groups HP35 from 277,36 ± 21,56 to 198,76 ±32,2 (p<0,01); and BHP35 from 261,14 ± 36,01 to 212,66 ± 25,99 (p<0,01), but the microhardness was reestablished after seven days. Regarding EDS analysis, a reduction in the mineral percentage immediately after bleaching with the use of VL was observed, however, after seven days it was reestablished. Regarding the color analysis, there was no difference among the groups evaluated. CONCLUSIONS The use of VL was effective as a dental bleaching tool and did not adversely affect the enamel surface after seven days of the ending of the bleaching protocol.
Collapse
|
19
|
|
20
|
Effect of a Self-Assembly Peptide on Surface Roughness and Hardness of Bleached Enamel. J Funct Biomater 2022; 13:jfb13020079. [PMID: 35735934 PMCID: PMC9224554 DOI: 10.3390/jfb13020079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 05/31/2022] [Accepted: 06/09/2022] [Indexed: 01/28/2023] Open
Abstract
After bleaching, enamel surfaces are damaged, contributing to erosion and tooth sensitivity. Although fluoride is used after bleaching to try and revert alterations, it is not capable of repairing tooth structure. This study compared the effect of a self-assembly peptide (P11-4), with and without fluoride, and sodium fluoride (NaF 2%) on the Knoop microhardness (KHN) and surface roughness (Ra (μm)) of bleached enamel with an in-office bleaching regimen. Enamel blocks of bovine teeth (5 × 5 × 2 mm) with standardized surface hardness were bleached with 35% carbamide peroxide, following the manufacturer’s instructions. The teeth were randomly divided into the following groups (n = 7) according to post-bleaching treatment: no treatment (negative control) (C-); 2% NaF (NaF); Curodont™ Repair (Repair); and Curodont™ Protect (Protect). Specimens were stored in artificial saliva at 37 °C. To evaluate the effect of the post-bleaching treatments, KHN and Ra were measured before bleaching (baseline) and 24 h and 7 days after bleaching. Data were submitted to repeated measures ANOVA and Bonferroni tests (α = 0.05). There were significant interactions between the study factors (p = 0.001). After 7 days, Repair (572.50 ± 79.04) and Protect (583.00 ± 74.76) specimens showed increased surface KHN, with values higher than the NaF (465.50 ± 41.50) and C- (475.22 ± 58.95) baseline values. There was no significant difference in KHN at 24 h among groups (p = 0.587). At 24 h after bleaching, Repair was significantly different from all groups (p < 0.05). Repair showed the lowest Ra (μm) values (0.133 ± 0.035). After seven days, there was no significant difference in Ra values among groups when compared to the baseline. The use of P11-4-based materials after bleaching resulted in the fastest recovery to baseline enamel properties.
Collapse
|
21
|
Use of Computerized Microtomography, Energy Dispersive Spectroscopy, Scanning Electron Microscopy, and Atomic Force Microscopy to Monitor Effects of Adding Calcium to Bleaching Gels. Oper Dent 2022; 47:E162-E173. [PMID: 35584324 DOI: 10.2341/20-217-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/06/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the mineral content, expressed by calcium (Ca) and phosphate (P), in dental enamel exposed to bleaching agents using micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and atomic force microscopy (AFM). METHODS Sixty bovine dental enamel specimens were randomly divided into three groups (n=20): HP35ca (bleached using 35% hydrogen peroxide with Ca); HP35wca (bleached using 35% hydrogen peroxide without Ca); and control (without bleaching). Five specimens from each group were used for SEM and EDS analyses, 10 specimens were used for AFM analysis, and the remaining five specimens were used for micro-CT analysis. The pH of the gels was measured using a pH meter. The EDS and micro- CT data were analyzed using one-way ANOVA and Pearson's correlation test. The AFM data were analyzed using one-way ANOVA (α=0.05). RESULTS The weight percentages of Ca and P obtained using EDS were similar between the bleached and control groups. Small, superficial changes were observed by SEM in the HP35wca group. The HP35ca group showed similar patterns to the control group. AFM results showed no significant changes in the enamel roughness in any of the tested groups. No significant difference in the volume or depth of structural enamel loss was found between gels with and without Ca. No mineral loss was observed in the dentin substrate. The EDS and micro-CT analysis data exhibited a high correlation (p<0.001). CONCLUSION The addition of Ca to the bleaching gel had no beneficial effect on the bleached tooth enamel in terms of composition, mineral loss, and surface roughness. Micro-CT results exhibited a high correlation with the EDS results.
Collapse
|
22
|
Bleaching effect of violet LED of 405-410 nm on stained endodontically treated teeth. Photodiagnosis Photodyn Ther 2022; 39:102929. [DOI: 10.1016/j.pdpdt.2022.102929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/05/2022] [Accepted: 05/25/2022] [Indexed: 10/18/2022]
|
23
|
Abstract
Tooth whitening is one of the most conservative procedures for increasing the aesthetics of patients, but the effect of bleaching on ceramic restorations has not been extensively studied. In this study, the bleaching effect on three dental restoration materials (polished/glazed lithium disilicate glass ceramic, leucite reinforced glass ceramic and zirconium dioxide ceramic) has been investigated in terms of surface roughness changes of the exposed samples. Philips Zoom NiteWhite 16% carbamide peroxide, Philips Zoom 6% hydrogen peroxide with following LED illumination and Pola Office 6% hydrogen peroxide have been used for ceramic bleaching. The experimental investigation and performed statistical analysis revealed that the highest surface roughness changes of all investigated ceramics were caused by the hydrogen peroxide and the lowest by carbamide peroxide. These findings correlated well with the colour changes observed in the same bleached dental ceramic samples indicating potential of carbamide peroxide as the most prospective bleaching agent.
Collapse
|
24
|
Design of a thermosensitive ibuprofen-loaded nanogel as smart material applied as anti-inflammatory in tooth bleaching: An in vivo study. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2022.103123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
25
|
Influence of two remineralizing agents on bleached enamel surface morphology and mineral composition – An In Vitro study. Indian J Dent Res 2022; 33:188-192. [DOI: 10.4103/ijdr.ijdr_896_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
26
|
Effects of Bleaching Associated with Er:YAG and Nd:YAG Laser on Enamel Structure and Bacterial Biofilm Formation. SCANNING 2021; 2021:6400605. [PMID: 35003484 PMCID: PMC8712178 DOI: 10.1155/2021/6400605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 12/03/2021] [Indexed: 06/14/2023]
Abstract
OBJECTIVE To compare the effects of bleaching associated with Er:YAG and Nd:YAG laser on enamel structure and mixed biofilm formation on teeth surfaces. MATERIALS AND METHODS Sixty-eight enamel samples were randomly divided into four groups (n = 17), control, Opalescence Boost only, Opalescence Boost plus Er: YAG laser, and Opalescence Boost plus Nd:YAG laser. The structure was observed using SEM after bleaching. Subsequently, the treated enamel samples were also cultured in suspensions of Streptococcus mutans, Streptococcus sanguis, Actinomyces viscosus, and Fusobacterium nucleatum (Fn) for 24 and 48 h. Biofilm formation was quantified by crystal violet staining, and the structure was visualized by confocal laser scanning microscopy. The data were analyzed using the Kruskal-Wallis method. RESULTS The enamel structure significantly changed after bleaching. There was no obvious difference in the biofilm formation after 24 h; however, after 48 hours, the amount of biofilm increased significantly. Remarkably, the amount was significantly higher on enamel bleached only, however, there was no significant difference between samples bleached with Er:YAG or Nd:YAG laser compared to the control. CONCLUSIONS Bleaching only appeared to markedly promote biofilm formation after 48 h, and the biofilms on samples bleached with Er:YAG or Nd:YAG laser did not change significantly, showing that bleaching with Er:YAG or Nd:YAG laser can be safely applied in clinical practice.
Collapse
|
27
|
Effects of 35% hydrogen peroxide solution containing hydrated calcium silicate on enamel surface. Clin Oral Investig 2021; 26:2133-2142. [PMID: 34591181 DOI: 10.1007/s00784-021-04194-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Accepted: 09/21/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES The objectives of this study were to develop a novel bleaching material containing hydrated calcium silicate (hCS) particles and investigate the effects of hCS on the bleaching efficacy, microhardness, and surface morphology of bovine enamel. MATERIALS AND METHODS To prepare the hCS particles, white Portland cement was mixed with distilled water and ground into a fine powder. The particles in various proportions were then mixed with 35% hydrogen peroxide solution (HP), while HP without hCS was used as a control (HP), and teeth whitening gel was used as a commercial control (CC). Following the thrice application of experimental and control solutions on the discolored bovine enamel surface for 15 min, color change (n = 10), microhardness (n = 10), and micromorphology (n = 2) of the enamel surface were analyzed. RESULTS The Δ E* of the enamel surface treated with the experimental solution containing hCS was significantly higher than that of the CC, but there were no significant differences between the different hCS contents. The experimental solution containing hCS reduced the percentage of microhardness loss on the enamel surface, and the percentage of microhardness loss significantly decreased as the content of hCS increased (p < 0.05). The erosion pattern was only observed on enamel surfaces treated with HP and CC. CONCLUSIONS This study suggests that HP containing hCS is effective in bleaching efficacy. In addition, hCS could also minimize the microhardness loss of tooth structure caused by HP and maintain enamel surface morphology. CLINICAL RELEVANCE This novel bleaching material is promising for inhibiting demineralization and promoting the remineralization of teeth during bleaching treatment in dental clinics.
Collapse
|
28
|
The micro-shear bond strength of resin cements to aged laser bleached enamel after using different desensitizing agents. Clin Exp Dent Res 2021; 8:248-256. [PMID: 34562058 PMCID: PMC8874074 DOI: 10.1002/cre2.496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 09/06/2021] [Accepted: 09/09/2021] [Indexed: 11/10/2022] Open
Abstract
Objectives To evaluate the micro‐shear bond strength of two resin cements to aged laser bleached enamel after the application of three different desensitizing agents. Materials and methods Forty extracted human central and lateral incisors were prepared and bleached using laser activation bleaching protocol. The teeth were assigned randomly into four groups for desensitization; G1: No post‐bleaching treatment, G2: GC MI Paste Plus, G3: Hydroxyapatite nanoparticles (n‐HAP) and G4: Flor‐Opal. Specimens were subjected to aging for 6 months. All groups were subdivided into two subgroups according to the resin cements used (dual‐curing resin cement and light‐curing resin cement). Results Flor‐Opal groups showed the highest statistically significant micro‐shear bond strength (MSBS), followed by GC MI Paste Plus and n‐HAP groups with no statistically significant difference between them. The light‐curing resin cement had statistically higher MSBS than dual‐curing resin cement in case of no‐post bleaching treatment and n‐HAP groups, and no statistical difference in case of GC MI Paste Plus and Flor‐Opal groups. Conclusion Usage of desensitizing agents containing, CPP‐ACP, n‐HAP or fluoride after laser bleaching can enhance the bond strength of the resin cements to enamel. Clinical significance The composition of the desensitizing agents applied after laser bleaching could interfere in bond strength values.
Collapse
|
29
|
Do dental bleaching sessions prior to orthodontic treatment change the bond strength of esthetic brackets? Dental Press J Orthod 2021; 26:e2119124. [PMID: 34468559 PMCID: PMC8405136 DOI: 10.1590/2177-6709.26.4.e2119124.oar] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2019] [Accepted: 04/23/2020] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE The aim of this experimental in vitro study was to evaluate whether dental bleaching performed before orthodontic treatment change the shear bond strength (SBS) of monocrystalline and polycrystalline esthetic brackets. METHODS Sixty (60) bovine incisors teeth were used and randomly divided into the following six groups (n=10): SCP (without bleaching/polycrystalline brackets); SCM (without bleaching/monocrystalline brackets); 1CP (one bleaching session/polycrystalline brackets); 1CM (one bleaching session/monocrystalline brackets); 3CP (three bleaching sessions/polycrystalline brackets); and 3CM (three bleaching sessions/monocrystalline brackets). The brackets were bonded seven days after the bleaching sessions. The samples were submitted to the SBS test in a universal testing machine (Instron model 4411) at 1 mm/min crosshead speed. The two-way analysis of variance (ANOVA) and the Tukey tests were performed at a 5% level of significance. After the mechanical test, samples were evaluated to determine the adhesive remnant index (ARI). RESULTS The SBS values were significantly higher for the monocrystalline brackets, when compared with the polycrystalline type (p< 0.0001), and significantly higher with three bleaching sessions than without bleaching (p< 0.0436). The ARI showed predominance of failures between the bracket and resin for all the groups (score 3). CONCLUSION Three dental bleaching sessions increased the SBS values. Monocrystalline brackets showed higher SBS values than the polycrystalline type.
Collapse
|
30
|
A Comparative Evaluation of Nanohydroxyapatite-Enriched Hydrogen Peroxide Home Bleaching System on Color, Hardness and Microstructure of Dental Enamel. MATERIALS 2021; 14:ma14113072. [PMID: 34199770 PMCID: PMC8199990 DOI: 10.3390/ma14113072] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 05/28/2021] [Accepted: 06/01/2021] [Indexed: 02/03/2023]
Abstract
This study aimed to evaluate two hydrogen peroxide (HP)-based at-home bleaching systems in order to analyze whether nano-hydroxyapatite (nHA) addition may represent a reliable and safe solution for tooth whitening without altering dental microstructure and hardness. Human third molars (N = 15) were treated with two bleaching agents, one containing 6%HP (6HP) and the other 6% HP nHA-enriched (6HP-nHA) with average particle diameter ranging from 5-20 nm. Their effects on enamel were assessed using a spectrophotometer, Vickers microhardness (VMH) test and Scanning Electron Microscopy (SEM), comparing the treated groups with the non-treated control group (CTR). Color analysis revealed improvement in whiteness in both groups compared to CTR. VMH test results showed no differences among the groups. SEM analysis highlighted no evident changes in the enamel microstructure of tested groups compared to CTR. At high magnification, in 6HP group, a slight increase in irregularities of enamel surface morphology was observed, while 6HP-nHA group displayed removal of the aprismatic layer but preservation of the intact prismatic structure. These results suggest that the 6HP-nHA agent may be recommended to provide reliable whitening treatment, without damaging the enamel micromorphology and hardness.
Collapse
|
31
|
Effects of different remineralizing agents on color stability and surface characteristics of the teeth following vital bleaching. Microsc Res Tech 2021; 84:2206-2218. [PMID: 33852758 DOI: 10.1002/jemt.23774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/22/2021] [Accepted: 03/30/2021] [Indexed: 11/06/2022]
Abstract
The aim of the study was to investigate the effects of various remineralizing agents on the color stability and surface characteristics of the teeth after vital bleaching. The extracted 96 human incisors were used for the study. Initially, the samples were randomly divided into two groups and exposed to in-office and at-home bleaching agents. Then, the groups were divided into six subgroups (n = 8), including the control group did not undergo remineralization after bleaching, according to five remineralizing agents (Gelato APF Gel, Remin Pro, Tooth Mousse, MI Paste Plus, Curodont Protect). Surface roughness was assessed at baseline, after bleaching and remineralization procedures. Color measurements of the samples were obtained at baseline, after bleaching and then after immersion in the staining solution following remineralization process. Scanning electron microscopy and atomic force microscopy (AFM) analyzes were carried out in order to examine the morphological changes on the surface of the enamel. The independent t-test, paired-samples t-test, and one-way ANOVA was used to compare the data and post-hoc LSD test to compare the difference among the study groups (α = .05). Surface roughness increased following in-office and at-home bleaching in all groups, and reduced after application of remineralizing agents in all groups. Significant differences were found among the groups with respect to changes in surface roughness and color values following treatment with remineralizing agents (p <.05). AFM analyses revealed increased surface roughness after bleaching and a reduction of rough surfaces following treatment with remineralizing agents. Remineralizing agents can be used to reduce postbleaching increase in surface roughness and to maintain color stability after bleaching.
Collapse
|
32
|
Effect of Vital Bleaching on Micromorphology of Enamel Surface: an in Vitro Study. Prim Dent J 2021; 10:126-131. [PMID: 33722125 DOI: 10.1177/2050168420980966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVES The aims of this in vitro study was to investigate the effects of bleaching agents commonly used in micromorphology of the enamel surface and to assess the effect of concentration and of adding fluoride in the bleaching agents. METHODS Sixty freshly extracted intact teeth were stored in distilled water. One half of each tooth was served as control, the other part was treated with bleaching agent. Samples were randomly divided into six groups of ten, according to the bleaching agents: G1- at-home-CP10; G2- at-home-CP16; G3- at-home-CP22; G4- in-office-CP35; G5- in-office-HP40 with fluoride; G6- in-office-HP40 without fluoride. Enamel specimens for each group were then submitted to a quantitative scanning electron microscopy. Number of pores and their diameter were measured to assess porosity of enamel surface. RESULTS SEM analysis revealed enamel surface porosity after bleaching. Significant increase in number and major diameter of pores in bleached samples (p<0.001) were observed. The comparison between samples treated with 10% PC and samples treated with 22% PC showed significant increase in number of pores (p=0.006) and major diameter (p=0.001) from samples treated with 22% PC. Statistical analyses showed significant increase in the number of pores (p=0.006) from samples treated with 40% HP without fluoride compared to samples treated with 40% HP containing fluoride. CONCLUSIONS Bleaching products with low concentration cause less porosity at surface of the enamel compared to concentrated products. Adding fluoride in the bleaching agent appears to reduce porosity of enamel surface.
Collapse
|
33
|
In Vitro Enamel Remineralization Efficacy of Calcium Silicate-Sodium Phosphate-Fluoride Salts versus NovaMin Bioactive Glass, Following Tooth Whitening. Eur J Dent 2021; 15:515-522. [PMID: 33622008 PMCID: PMC8382453 DOI: 10.1055/s-0040-1722484] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objectives
This study aimed to evaluate the effect of in-office bleaching on the enamel surface and the efficacy of calcium silicate-sodium phosphate-fluoride salt (CS) and NovaMin bioactive glass (NM) dentifrice in remineralizing bleached enamel.
Materials and Methods
Forty extracted premolars were sectioned mesio-distally, and the facial and lingual enamel were flattened and polished. The samples were equally divided into nonbleached and bleached with 38% hydrogen peroxide (HP). Each group was further divided according to the remineralization protocol (
n
= 10); no remineralization treatment (nontreated), CS, or NM, applied for 3 minutes two times/day for 7 days, or CS combined with NR-5 boosting serum (CS+NR-5) applied for 3 minutes once/day for 3 days. The average Knoop hardness number (KHN) and surface roughness (utilizing atomic force microscopy) were measured. Surface topography/elemental analysis was analyzed by using scanning electron microscopy/energy dispersive X-ray analysis. All the tests were performed at baseline, after bleaching, and following each remineralization protocol. Data were statistically analyzed by two-way analysis of variance and Bonferroni post hoc multiple comparison tests (α = 0.05).
Results
HP significantly reduced KHN and increased roughness (
p
< 0.05). All remineralization materials increased the hardness and reduced the surface roughness after bleaching except NM, which demonstrated significantly increased roughness (
p
< 0.05). Ca/P ratio decreased after bleaching (
p < 0.05
), and following treatment, CS and CS+NR-5 exhibited higher remineralization capacity in comparison to NM (
p
< 0.05).
Conclusion
Although none of the material tested was able to reverse the negative effect of high-concentration in-office HP on enamel completely, the remineralization efficacy of CS and CS+NR-5 was superior to that of NM.
Collapse
|
34
|
ATR-FTIR, EDS and SEM evaluations of enamel structure after treatment with hydrogen peroxide bleaching agents loaded with nano-hydroxyapatite particles. PeerJ 2021; 9:e10606. [PMID: 33575125 PMCID: PMC7849511 DOI: 10.7717/peerj.10606] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 11/28/2020] [Indexed: 01/04/2023] Open
Abstract
Background Tooth whitening is one of the most requested dental treatments, but it still presents some side effects. Indeed, the bleaching agent can generate patients’ discomfort and dental hard tissue damages, not achieving an efficient and long-lasting treatment with optimum whitening effect. To overcome these limitations, the bleaching agents containing nano-hydroxyapatite can represent a reliable solution to avoid these detrimental effects. Methods In this study, human third molars were treated with commercial bleaching agents, containing nano-hydroxyapatite (nHA) and 6% (at-home treatment), 12% and 18% (in-office treatments) of hydrogen peroxide (HP), named respectively G1, G2 and G3. The results were evaluated descriptively and analytically using Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR), Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray spectroscopy (EDS), comparing the treated groups with a commercial gel containing 10% carbamide peroxide (CONV) and with a non-treated control group (CTRL). Results ATR-FTIR analysis revealed a similar composition in carbonates and phosphates for CTRL, G1 and G2 groups, which showed no significant differences in their spectral profiles; an increased amount of organic matter was found in G3, while CONV displayed an intermediate behavior. SEM analysis did not highlight significant changes in the enamel microstructure of G1 and CONV when compared to CTRL; the pattern observed in G2 presented a slight increase of enamel irregularities, while G3 displayed a partial removal of the aprismatic layer and microporosities. No evident effects due to nHA were observed in the structure of the hydroxyapatite component of G1, G2 and CONV, if compared to CTRL, while G3 showed a slight loss of crystallinity. In all groups, EDS identified slight changes in the concentration of chemical elements O and Ca, while the Ca/P ratio was similar when compared to CTRL. Conclusion The obtained results suggest that the application of the tested commercial bleaching agents, with a concentration of HP up to 12%, does not alter the morphological and chemical composition of the enamel surface and maintains its crystallinity.
Collapse
|
35
|
A comparative evaluation of the effect of three different concentrations of in-office bleaching agents on microhardness and surface roughness of enamel – An in vitro study. Dent Res J (Isfahan) 2021. [DOI: 10.4103/1735-3327.318944] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
36
|
Effects of different bleaching application time on tooth color and mineral alteration. Ann Anat 2020; 233:151590. [PMID: 32931915 DOI: 10.1016/j.aanat.2020.151590] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 07/20/2020] [Accepted: 08/03/2020] [Indexed: 11/23/2022]
Abstract
BACKGROUND The effects of HP-based products upon dental enamel are inconclusive. PURPOSE The purpose of this study was to evaluate the colour and mineral changes caused by the bleaching agent applications at different durations on the enamel surface. BASIC PROCEDURES 60 caries-free lower central incisor extracted for periodontal reasons were standardized for enamel and dentin thickness after cone-beam computed tomography (CBCT) measurements in terms of mineral (n = 24) and colour change (n = 36). All teeth were divided into 3 groups according to different bleaching durations for colour (n = 12) and mineral change (n = 8) measurements. The samples for mineral change were examined with the -energy scattering X-ray (EDX, JSM-6390 LV, Jeol Inc., Japan) device before and 2 weeks after the application. For colour change, the measurement of the samples was performed with spectrophotometer device (VITA EasyShade 4.0, Germany). Opalescence Boost PF 40% (Ultradent Products, USA) was applied for 20 min (min) in Group 1, 40 min in Group 2 and 60 min in Group 3. In order to determine the efficacy of bleaching, colour measurements were repeated at 24 h, 7 and 14 days after the application. In the intragroup comparison, Friedman and Wilcoxon tests were used for non-normally distributions, while repeated variance analysis and paired t test were used for normally distributions in dependent variables. In the intergroup comparison, ANOVA and LSD tests were used for normally distributions, while Kruskal-Wallis and Dunn tests were used for non-normally distributions in independent variables. p < 0.05 was considered significant. MAIN FINDINGS In the study, statistically significant difference was observed between all groups in terms of colour change at different measurement times (p < 0.05). The highest ΔE00 values were observed in Group 3 (ΔE003 = 8.37 ± 2.15); the lowest value was observed in Group 1 (ΔE001 = 4.74 ± 1.26). Ca values were similar increase among all groups (p > 0.05). The highest Ca values were observed in Group 3 (69.91 ± 5.34); the lowest value was observed in Group 2 (66.08 ± 1.50). P values were similar increase among all groups (p > 0.05). The lowest P values were observed in Group 3 (26.54 ± 5.92); the highest value was observed in Group 2 (29.86 ± 2.26). PRINCIPAL CONCLUSIONS Effective whitening was achieved in all study groups. When the results are evaluated as versatile in terms of bleaching effectiveness and mineral change, the most ideal bleaching duration was determined as 40 min (Group 2).
Collapse
|
37
|
In Vitro Re-Hardening of Bleached Enamel Using Mineralizing Pastes: Toward Preventing Bacterial Colonization. MATERIALS 2020; 13:ma13040818. [PMID: 32054090 PMCID: PMC7079603 DOI: 10.3390/ma13040818] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 01/30/2020] [Accepted: 02/07/2020] [Indexed: 12/14/2022]
Abstract
The search for materials able to remineralize human hard tissues is a modern medical challenge. In this study, the protective effect on the enamel microhardness by a paste based on hydroxyapatite and sodium fluoride (Remin Pro) was evaluated after two different enamel bleaching procedures. Forty sound human incisors were randomly assigned to different treatments: bleaching with an in-office agent (Perfect Bleach Office+); bleaching with an at-home agent (Perfect Bleach); bleaching with the in-office agent followed by the prophylaxis paste; bleaching with the at-home agent followed by the prophylaxis paste; no treatment (control). Bleaching was performed at 0, 8, 24 and 32 h, followed by a 3-min re-mineralizing treatment in the subgroups designed to receive it. Specimens underwent a micro-hardness tester and a mean Vickers Hardness number was considered for each specimen. ANOVA exhibited significant differences among groups. Post-hoc Tukey testing showed significant micro-hardness decrease after the application of both the two bleaching agents. The treatment with prophylaxis paste significantly increased the micro-hardness values of bleached enamel.
Collapse
|
38
|
Effect of Chitosan on Mineral Content of Human Tooth After Bleaching: An SEM-EDX Study. JOURNAL OF ADVANCED ORAL RESEARCH 2019. [DOI: 10.1177/2320206819881606] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Aim and Background: 35% carbamide peroxide can cause adverse effects on the structure and composition of teeth. However, the addition of calcium and fluoride in bleaching agents may reduce enamel demineralization. The aim of the study is to evaluate the chemical changes in a tooth submitted to 35% of carbamide peroxide containing chitosan and carbopol as a carrier system using scanning electron microscopy/energy dispersive x-ray analysis (SEM-EDX). Materials and Methods: 30 freshly extracted anterior teeth were given root canal treatment. The teeth were randomly divided into 3 groups. Group 1 was Opalescence PF (35% carbamide peroxide), group 2 was chitosan with 35% carbamide peroxide, and group 3 was a control group (no treatment). All canals were filled with 0.06 tapered gutta-percha and AH-plus sealer. Then, intracoronal bleaching was applied. SEM-EDX analysis was performed to determine whether bleaching procedures changed the mineral content of the tooth. While SEM-EDX analysis, the tooth was analyzed based on elemental content and elemental distribution from standardized points under 300× magnification. Statistical analysis was performed with one way analysis of variance. Results: There was no significant difference in C, O, Na, P, Mg, K, and S values and the Ca/P ratio obtained by SEM-EDX analysis among groups ( P > .05), whereas the Ca level was significantly lower in Opalescence PF group than the control group ( P < .05). Conclusions: The results of this study show that chitosan does not cause mineral loss and dissolution in the inorganic content of a tooth. Thus, chitosan can be used as an alternative carrier system in the bleaching agent.
Collapse
|
39
|
The application of casein phosphopeptide and amorphous calcium phosphate with fluoride (CPP-ACPF) for restoring mineral loss after dental bleaching with hydrogen or carbamide peroxide: An in vitro study. Ann Anat 2019; 225:48-53. [DOI: 10.1016/j.aanat.2019.05.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Revised: 05/06/2019] [Accepted: 05/06/2019] [Indexed: 10/26/2022]
|
40
|
Comparison of Bleaching Products With Up to 6% and With More Than 6% Hydrogen Peroxide: Whitening Efficacy Using BI and WI D and Side Effects - An in vitro Study. Front Physiol 2019; 10:919. [PMID: 31543822 PMCID: PMC6728628 DOI: 10.3389/fphys.2019.00919] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 07/05/2019] [Indexed: 12/30/2022] Open
Abstract
The aim of this study was to evaluate the effect of bleaching agents containing different concentrations of hydrogen peroxide (HP) on color-change and on enamel-surface in bovine teeth. Furthermore the influence on cell viability and proliferation was investigated. Two hundred and forty teeth were randomly assigned into four groups (home bleaching ≤6%, in-office bleaching ≤6%, in-office bleaching > 6% HP, and control group). Bleaching was performed after artificial staining and the bleached index (BI) as well as the whiteness index (WID) was measured at several time points. Chemical analysis for HP concentrations and the pH of the bleaching products was done. Furthermore, enamel surfaces of randomly selected specimens were analyzed using scanning electron microscopy (SEM) and cytotoxicity of the tested bleaching products was evaluated in vitro using dental pulp cells (DPCs) and L929 cells. A statistically significant whitening effect was observed in almost all products. As expected all investigated products resulted in decreased cell viability, however, with different values of LC50 (median lethal concentration). SEM analysis showed an analog of enamel alterations with decreasing pH, increasing exposure time, and increasing HP concentration. Bleaching agents containing a low HP concentration are considered to be effective and to have less damaging effects on enamel and tested cells.
Collapse
|
41
|
Remineralization potential of grape seed extract hydrogels on bleached enamel compared to fluoride gel: An in vitro study. J Clin Exp Dent 2019; 11:e401-e407. [PMID: 31275511 PMCID: PMC6599700 DOI: 10.4317/jced.55556] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 04/01/2019] [Indexed: 11/17/2022] Open
Abstract
Background Remineralizing of bleached enamel is a common procedure that aims to compensate enamel mineral lose. This study aimed to evaluate the remineralization effectiveness of experimentally prepared grape seed extract hydrogels (GSE) compared to fluoride gel on bleached enamel. Material and Methods Thirty extracted maxillary incisor were bleached using white smile bleaching agent. Bleached specimens were divided into three groups (10/group) according to the remineralizing agents tested: [GSE 6%, GSE 10%, or fluoride gel]. After bleaching and remineralization procedure, the specimens were stored in artificial saliva at 37°C. Micro-hardness and Energy-Dispersive X-ray and ultra-morphological evaluation were tested at baseline, after bleaching and after remineralization. Results Statistical significant decrease on mean micro-hardness values had resulted after bleaching procedure compared to baseline, followed by a significant increase in GSE (10%) and fluoride groups. GSE (6%) application showed the least statistical significant mean micro-hardness, which was statistically insignificant different compared to bleaching procedure. Elemental analysis results revealed a statistical significant decrease on Ca, and Ca/P ratios (At%) values after bleaching compared to baseline, followed by a significant increase after treatment with all tested remineralizing gels. SEM photomicrograph of sound enamel shows smooth uniform appearance with few pores. Bleached enamel showed irregular pitted disorganized enamel surface. Bleached enamel exposed to GSE and fluoride gel showed occlusion of enamel surface porosities and precipitates of different sizes. Conclusions The specially prepared GSE hydrogels has positive effects on the remineralization process of bleached enamel making it an effective natural agent with remineralizing potential. Key words:Remineralization, bleaching, grape seed extract, fluoride, enamel.
Collapse
|
42
|
Non-invasive analysis of bleaching effect of hydrogen peroxide on enamel by reflectance confocal microscopy (RCM): study of series of cases. Odontology 2019; 107:285-290. [PMID: 30810841 DOI: 10.1007/s10266-019-00416-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 08/07/2018] [Indexed: 12/14/2022]
Abstract
The aim of this study is to evaluate in vivo the effects of in-office tooth whitening hydrogen peroxide (HP) agent on enamel-microstructured surface by a reflectance confocal microscopy (RCM). Ten healthy volunteers assisted at the Dental School presenting teeth with vital pulp were selected. The 35% HP whiteness product was applied in two visits on discolored teeth, 1-week interval between, via 20-min applications. A commercially available hand-held RCM (Vivascope3000®, Lucid, Rochester, NY, USA) was used to image in vivo the dental surface of the selected tooth of each volunteer. Twenty upper central incisors' vestibular surfaces were imaged, before bleaching (T0), immediately after (T1) and 1 week later (T2). The peculiar structure of the enamel was seen at T0. After bleaching, white reflective circular bodies were found all over the teeth surfaces, which disappear 1 week later (T2). When the HP gel® was imaged, the same white circular areas were observed. Going deeper, the regular enamel architecture was preserved. Textural analysis of the images in T0 and T2 was performed: GLCM parameters were extracted. Mann-Whitney U test was performed to evaluate statistical differences between two groups of data (p > 0.05). Finally, 35 prisms were randomly selected from T0 and T2 image and diameters were measured; a paired t test was performed (p = 0.381). The RCM is a promisor tool for investigating the features of enamel in vivo, immediately after bleaching procedures, as well as longitudinally.
Collapse
|
43
|
Abstract
Objective The purpose of this study was to assess the hardness, mineral content, surface roughness, and micromorphology of sound and slightly demineralized enamels, before and after bleaching procedure using 10% carbamide peroxide. Methods Sixty bovine dental blocks were randomly divided into the following two groups: 30 slabs were submitted to three cycles of pH and 30 slabs were noncycled. Hardness (n=10) was measured using the microhardness tester with Knoop indenter under a 50 g load for 5 seconds. The calcium/phosphate (Ca/P) ratio (n=10) was obtained using a micro-energy-dispersive X-ray fluorescence (μ-EDXRF) spectrometer. The measurement of roughness average (n=10) was performed using a surface roughness tester. Specimens were bleached 6 hours/day during 21 days, and then, physicochemical properties were re-evaluated. Two additional specimens were carried out to evaluate surface micromorphology using the scanning electron microscopy. Data were statistically analyzed by ANOVA and Tukey's test (α=0.05). Results Sound and slightly demineralized enamels showed no difference in Ca/P ratio after dental bleaching according to the μ-EDXRF analysis, but the Ca/P ratio decreased after bleaching for slightly demineralized enamel. Bleaching treatment decreased the hardness and increased the surface roughness, causing micromorphology alterations. Conclusion Therefore, bleaching procedure promoted change in bovine enamel surface and increased the demineralization of slightly demineralized enamel but not affected the mineral content of sound enamel.
Collapse
|
44
|
Effects of in-office bleaching agent combined with different desensitizing agents on enamel. J Appl Oral Sci 2018; 27:e20180233. [PMID: 30427477 PMCID: PMC6223786 DOI: 10.1590/1678-7757-2018-0233] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 08/07/2018] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To analyze color change, microhardness and chemical composition of enamel bleached with in-office bleaching agent with different desensitizing application protocols. MATERIALS AND METHODS One hundred and seventeen polished anterior human enamel surfaces were obtained and randomly divided into nine groups (n = 13). After recording initial color, microhardness and chemical composition, the bleaching treatments were performed as G1: Signal Professional White Now POWDER&LIQUID FAST 38% Hydrogen peroxide(S); G2: S+Flor Opal/0.5% fluoride ion(F); G3: S+GC Tooth Mousse/Casein Phosphopeptide-Amorphous Calcium Phosphate (CPP-ACP) paste(TM); G4: S+UltraEZ/3% potassium nitrate&0.11% fluoride(U); G5: S+Signal Professional SENSITIVE PHASE 1/30% Nano-Hydroxyapatite (n-HAP) suspension(SP); G6: S-F mixture; G7: S-TM mixture; G8: S-U mixture; G9: S-SP mixture. Color, microhardness and chemical composition measurements were repeated after 1 and 14 days. The percentage of microhardness loss (PML) was calculated 1 and 14 days after bleaching. Data were analyzed with ANOVA, Welch ANOVA, Tukey and Dunnett T3 tests (p<0.05). RESULTS Color change was observed in all groups. The highest ΔE was observed at G7 after 1 day, and ΔE at G8 was the highest after 14 days (p<0.05). A decrease in microhardness was observed in all groups except G6 and G7 after 1 day. The microhardness of all groups increased after 14 days in comparison with 1 day after bleaching (p>0.05). PML was observed in all groups except G6 and G7 after bleaching and none of the groups showed PML after 14 days. No significant changes were observed after bleaching at Ca and P levels and Ca/P ratios at 1 or 14 days after bleaching (p>0.05). F mass increased only in G2 and G6, 1 day after bleaching (p<0.05). CONCLUSIONS The use of desensitizing agents containing fluoride, CPP-ACP, potassium nitrate or n-HAP after in-office bleaching or mixed in bleaching agent did not inhibit the bleaching effect. However, they all recovered microhardness of enamel 14 days after in-office bleaching.
Collapse
|
45
|
Effects of experimental bleaching agents on the mineral content of sound and demineralized enamels. J Appl Oral Sci 2018; 26:e20170589. [PMID: 30304124 PMCID: PMC6172021 DOI: 10.1590/1678-7757-2017-0589] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Accepted: 06/25/2018] [Indexed: 11/22/2022] Open
Abstract
High concentrations of hydrogen peroxide can cause adverse effects on composition and structure of teeth. However, the addition of calcium and fluoride in bleaching agents may reduce enamel demineralization.
Collapse
|
46
|
Effect of CPP-ACP on efficacy and postoperative sensitivity associated with at-home vital tooth bleaching using 20% carbamide peroxide. Clin Oral Investig 2018; 23:1555-1559. [PMID: 30121734 DOI: 10.1007/s00784-018-2574-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 08/09/2018] [Indexed: 10/28/2022]
Abstract
OBJECTIVES To evaluate CPP-ACP effect on colour change and tooth sensitivity (TS) associated with at-home vital tooth bleaching using 20% carbamide peroxide (CP). METHODS A randomised double-blind placebo-controlled clinical trial was conducted to measure the TS and tooth colour change of 24 patients at 3-day, 7-day, 14-day and 30-day periods. The participants were instructed to apply 20% CP (7 days-04 h each) followed by the application of either CPP-ACP or non-active placebo paste, delivered by the bleaching custom tray (7 days-30 min each). Lightness (L*), redness (a*) and yellowness (b*) were measured using a digital spectrophotometer and the overall colour changes ∆E were calculated. ∆E and TS values were statistically analysed. The level of statistical significance was established at p = 0.05. RESULTS No significant differences were detected between CPP-ACP and placebo groups regarding the ∆E. The ∆E measurements presented significant differences within CPP-ACP groups between 3-day vs. 14-day and 30-day measurements. The CPP-ACP application reduced significantly the TS reported by the participants at 3-day when compared with the placebo group. CONCLUSION The application of CPP-ACP paste during at-home tooth bleaching with 20% CP was beneficial since its use reduced the TS and presented no deteriorating effect on the colour change. CLINICAL RELEVANCE The current findings are of importance for clinicians to manage TS reported by patients when a high CP bleaching agent is used.
Collapse
|