1
|
Haridy MF, Ahmed HS, Ahmed RN, Elhusseiny SE. Effect of different cavity designs and CAD/CAM blocks on fracture resistance of maxillary premolars with MOD cavities. Odontology 2025:10.1007/s10266-025-01079-4. [PMID: 40100538 DOI: 10.1007/s10266-025-01079-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2024] [Accepted: 02/18/2025] [Indexed: 03/20/2025]
Abstract
The aim of the study was to evaluate the fracture resistance of maxillary premolars restored by different CAD/CAM blocks with different MOD cavity designs. A total of 56 maxillary premolars were selected and randomly divided into 4 groups. I: intact teeth as a positive control group. Standardized MOD cavities were prepared in the remaining group specimens. II: teeth had MOD cavities but were left unrestored as a negative control group. III: MOD preparations restored with inlays with no cusp reduction. IV: MOD preparations restored with overlays with cusp reduction. Group III and IV were further subdivided into two subgroups according to material used, i.e., either lithium disilicate or composite CAD/CAM blocks. All specimens were subjected to 5000 cycles of thermocycling and then tested for fracture resistance. Failure patterns were also examined. Data were statistically analyzed using Welch one-way ANOVA followed by Games-Howell's post hoc test. The results showed significant differences among the experimental groups (p < 0.001). The highest fracture resistance value was observed in positive control group, followed by overlays restored with lithium disilicate blocks. This was followed by overlays restored with composite blocks, then inlays restored by lithium disilicate blocks, inlays restored with composite blocks, while the lowest fracture resistance value was found in negative control group. Regarding failure modes, there was a significant difference between different groups (p < 0.001). The conclusion was that fracture resistance of maxillary premolars restored by CAD/CAM inlays and overlays are greatly affected by the cavity design and material type.
Collapse
Affiliation(s)
- Mohamed F Haridy
- Department of Conservative Dentistry, Faculty of Dentistry, The British University, Al Shorouk City, Egypt.
- Department of Conservative Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt.
| | - Hend S Ahmed
- Department of Conservative Dentistry, Faculty of Dentistry, The British University, Al Shorouk City, Egypt
| | - Radwa Nagy Ahmed
- Department of Conservative Dentistry, Faculty of Dentistry, The British University, Al Shorouk City, Egypt
| | | |
Collapse
|
2
|
Hafez ME, Abd El-Ghany AA, Taha AI, Amin A. In vitro assessment of fracture resistance of endodontically treated teeth restored with short fiber reinforced resin based composite and ceramic overlays. BMC Oral Health 2025; 25:211. [PMID: 39922996 PMCID: PMC11807320 DOI: 10.1186/s12903-025-05480-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Accepted: 01/13/2025] [Indexed: 02/10/2025] Open
Abstract
BACKGROUND Conventional full-coverage crowns are used after endodontic treatment to enhance the fracture toughness of these teeth. However, these crowns lead to extensive loss of tooth structure. Continuous trials to develop a biomimetic conservative direct restorative material that can be used as a dentine substitute led to the development of the short fiber reinforced resin composite. METHODS Fifty extracted intact upper premolar teeth were selected. Ten teeth serve as positive control without any treatment (Group 1). The remaining forty teeth were received root canal therapy. Standardized MOD cavities were prepared in 30 teeth of them, then they were randomly divided into three groups: Group 2: teeth received no coronal restorations; Group 3: MOD cavities restored with packable short fiber reinforced composite (EverX Posterior), followed by 2 mm nanocomposite; and Group 4: MOD cavities restored with flowable short fiber reinforced composite (EverX Flow), followed by 2 mm nanocomposite. For the remaining ten teeth, MOD cavities were prepared, and cusps were reduced to receive ceramic overlays (CeraSmart 270). After thermocycling, fracture load is applied using the Instron Universal machine until samples fracture. Fracture loads were recorded, and fracture mode was evaluated. All data were subjected to statistical analysis. RESULTS Teeth restored with CeraSmart 270 overlays and those restored with high aspect ratio short fiber-reinforced resin composite recorded the highest resistance to fracture with no significant differences between them. CONCLUSIONS EverX Posterior may be considered a conservative substitute for indirect overlays to restore endodontically treated teeth with MOD cavities. CLINICAL RELEVANCE Clinically, using fiber reinforced composite as a substitute for indirect restorations preserves the tooth structure and provides proper resistance to fracture.
Collapse
Affiliation(s)
| | | | - Ahmed Ismail Taha
- Faculty of Dentistry, Kafr Elsheikh University, Kafr Elsheikh, Egypt
| | - Ashraf Amin
- Faculty of Dentistry, Kafr Elsheikh University, Kafr Elsheikh, Egypt
| |
Collapse
|
3
|
Refaey HS, Abdelkader SH, Aly YM. Fracture resistance and marginal fit of three different overlay designs using advanced zirconia-reinforced lithium disilicate CAD/CAM material. BMC Oral Health 2025; 25:20. [PMID: 39755589 DOI: 10.1186/s12903-024-05315-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2024] [Accepted: 12/09/2024] [Indexed: 01/06/2025] Open
Abstract
BACKGROUND Conservative dentistry introduced modern restoration designs, contributing to the greater use of partial-coverage ceramic restorations. New strong bondable ceramic materials made fabricating partial coverage ceramic restorations easier to restore the badly destructed teeth. AIM OF THE STUDY This study investigated the impact of three distinct overlay preparation designs on the marginal fit (both before and after thermal aging) and the fracture resistance of overlay restorations fabricated using advanced zirconia-reinforced lithium disilicate (ALD) CAD/CAM glass-ceramic blocks. MATERIALS AND METHODS Using a standardized preparation protocol, three typodont molars were prepared to receive three different indirect overlay ceramic restoration designs. The typodont teeth were duplicated to get 27 resin dies that were randomly allocated into three groups (n = 9) based on the preparation design; group (O): a traditional overlay preparation with anatomical occlusal reduction, group (OS): anatomical occlusal reduction with circumferential shoulder finish line, and group (OG): anatomical occlusal reduction with a central groove preparation at the mid-occlusal surface. After standardized restorations fabricated following the manufacturer's guidelines, the restorations were cemented to their corresponding dies and exposed to thermal aging corresponding to 6-month clinical service. Marginal gap was measured before and after thermal aging procedure using an optical microscope. To measure fracture resistance, specimens were loaded till failure using the universal testing machine. The Kruskal Wallis test was utilized to assess data among the groups, followed by Dunn's post hoc test with Bonferroni correction. Differences in the marginal fit before and after thermal aging were evaluated using Wilcoxon Sign Rank test. RESULTS A statistically significant difference in marginal fit was observed between the studied groups, with a p-value of 0.032 where group OS has the lowest micro gap compared to group OG and group O. The fracture resistance group (O) recorded the highest fracture resistance with a statistically significant difference between the studied groups at p value = 0.043. CONCLUSIONS Adjusting the tooth preparation significantly influenced both the fracture resistance load and the marginal fit observed for advanced zirconia-reinforced lithium disilicate glass-ceramic (ALD) overlays.
Collapse
Affiliation(s)
- Heidi Saad Refaey
- Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Sanaa H Abdelkader
- Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Yasser M Aly
- Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
4
|
Attia M, Fahmy N, Shaker A, Salah T. The effect of different materials and cavity designs on fracture resistance of ceramic partial coverage. J ESTHET RESTOR DENT 2024; 36:1459-1465. [PMID: 39076156 DOI: 10.1111/jerd.13286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 06/22/2024] [Accepted: 07/12/2024] [Indexed: 07/31/2024]
Abstract
BACKGROUND Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces. METHODS Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (n = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples. RESULTS Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs. CONCLUSIONS Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did. CLINICAL SIGNIFICANCE When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.
Collapse
Affiliation(s)
- Mahmoud Attia
- Fixed Prosthodontic Department, Faculty of Dentistry, October University for Modern Sciences and Arts, Giza, Egypt
| | - Nadia Fahmy
- Fixed Prosthodontic Department, Faculty of Dentistry, October University for Modern Sciences and Arts, Giza, Egypt
| | - Atef Shaker
- Fixed Prosthodontic Department, Faculty of Dentistry, Cairo University, Giza, Egypt
| | - Tarek Salah
- Fixed Prosthodontic Department, Faculty of Dentistry, Ain Shams University, Giza, Egypt
| |
Collapse
|
5
|
Hofsteenge JW, Bresser RA, Buijs GJ, van der Made SA, Özcan M, Cune MS, Gresnigt MM. Clinical performance of bonded partial lithium disilicate restorations: The influence of preparation characteristics on survival and success. J Dent 2024; 142:104828. [PMID: 38159900 DOI: 10.1016/j.jdent.2023.104828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 12/21/2023] [Accepted: 12/27/2023] [Indexed: 01/03/2024] Open
Abstract
OBJECTIVES The aim of this study was to investigate the influence of preparation characteristics on the survival, success, and clinical performance of partial indirect lithium disilicate restorations with immediate dentin sealing. METHODS This retrospective clinical study evaluated partial indirect lithium disilicate restorations placed in conjunction with Immediate Dentin Sealing (IDS) in (pre)molar teeth between March 2018 and May 2021. The restorations were luted using pre-heated composite. The study focused on survival, success, and clinical performance, which was evaluated using the modified United States Public Health Service (USPHS) criteria. Results were analyzed using the Kaplan-Meier estimates, log-rank tests, and Fisher exact tests. RESULTS Partial indirect lithium disilicate restorations (N = 454) were evaluated in 214 patients. The mean evaluation time was 37 months, with a cumulative survival rate of 99.2 % and a cumulative success rate of 97.6 %. Fourteen failures occurred, with endodontic pathology as the predominant failure mode, followed by secondary caries, debonding, and tooth fracture. No statistically significant influence of the preparation variables on survival and success was observed (p > .05). The short-term clinical performance was clinically acceptable in > 90 % of the evaluations. CONCLUSIONS This retrospective study on partial indirect lithium disilicate restorations in conjunction with IDS demonstrates survival and success rates of 99.2 and 96.7 % over a mean evaluation period of 37 months. A marked influence of the studied preparation characteristics on the survival, success and clinical performance of lithium disilicate partial restorations could not be demonstrated. Partial lithium disilicate restorations exhibit good clinical performance in >90 % of the cases. CLINICAL SIGNIFICANCE The results of this study suggest that preparation characteristics had no significant impact on the survival, success, and clinical performance of partial lithium disilicate restorations in conjunction with IDS. Results show good clinical performance and high survival and success rates, regardless of preparation characteristics.
Collapse
Affiliation(s)
- Jelte W Hofsteenge
- Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, Groningen, AV 9713, the Netherlands.
| | - Rijkje A Bresser
- Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, Groningen, AV 9713, the Netherlands
| | - Gerrit J Buijs
- Private Practice Buijs Tandartsen, Groningen, the Netherlands
| | | | - Mutlu Özcan
- Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, Groningen, AV 9713, the Netherlands; Center of Dental Medicine, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | - Marco S Cune
- Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, Groningen, AV 9713, the Netherlands; Department of Oral Maxillofacial Surgery, Prosthodontics and Special Dental Care, St. Antonius Hospital, Nieuwegein, the Netherlands
| | - Marco Mm Gresnigt
- Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, Groningen, AV 9713, the Netherlands; Department of Special Dental Care, Martini Hospital, Groningen, the Netherlands
| |
Collapse
|
6
|
Hofsteenge JW, Carvalho MA, Borghans PM, Cune MS, Özcan M, Magne P, Gresnigt MMM. Effect of preparation design on fracture strength of compromised molars restored with lithium disilicate inlay and overlay restorations: An in vitro and in silico study. J Mech Behav Biomed Mater 2023; 146:106096. [PMID: 37659167 DOI: 10.1016/j.jmbbm.2023.106096] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 08/24/2023] [Accepted: 08/28/2023] [Indexed: 09/04/2023]
Abstract
PURPOSE The objective of this study was to determine the influence of different preparation designs on the fracture strength, failure type, repairability, formation of polymerization-induced cracks, and tooth deformation of structurally compromised molars restored with lithium disilicate inlays and overlays in combination with Immediate Dentin Sealing (IDS). MATERIAL AND METHODS Human molars (N = 64) were randomly assigned to four different preparation designs: Undermined Inlay (UI), Extended Inlay (EI), Restricted Overlay (RO), and Extended Overlay (EO). The teeth were restored using lithium disilicate partial restorations and subjected to thermomechanical fatigue in a chewing simulator (1,2 × 10 (Mondelli et al., 2007) cycles on 50 N, 8000x 5-55 °C), followed by load to failure testing. In silico finite element analysis was conducted to assess tooth deformation. Polymerization-induced cracks were evaluated using optical microscopy and transillumination. Fracture strengths were statistically analyzed using a Kruskal-Wallis test, while the failure mode, repairability, and polymerization cracks were analyzed using Fisher exact test. RESULTS The propagation of polymerization-induced cracks did not significantly differ among preparation designs. All specimens withstood chewing simulator fatigue, with no visible cracks in teeth or restorations. Fracture strength was significantly influenced by preparation design, with restricted overlay (RO) showing higher fracture strength compared to extended inlay (EI) (p = .042). Tooth deformation and fracture resistance correlated between in vitro and in silico analyses). UI exhibited a statistically less destructive failure pattern than EO (p < .01) and RO (p = .036). No statistically significant influence of the preparation design on repairability was observed. Groups with higher repairability rates experienced increased tooth deformation, leading to less catastrophic failures. CONCLUSIONS The preparation design affected the fracture strength of compromised molars restored with lithium disilicate inlays and overlays, with significantly lower fracture strength for an extended inlay. The failure pattern of lithium disilicate overlays is significantly more destructive than that of undermined and extended inlays. The finite element analysis showed more tooth deformation in the inlay restorations, with lower forces in the roots, leading to less destructive fractures. Since cusp coverage restorations fracture in a more destructive manner, this study suggests the undermined inlay preparation design as a viable option for restoring weakened cusps.
Collapse
Affiliation(s)
- Jelte W Hofsteenge
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands.
| | | | - Pauline M Borghans
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands
| | - Marco S Cune
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; St. Antonius Hospital Nieuwegein, Department of Oral-Maxillofacial Surgery, Prosthodontics and Special Dental Care, Nieuwegein, the Netherlands
| | - Mutlu Özcan
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; University of Zurich, Center of Dental Medicine, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Zurich, Switzerland
| | - Pascal Magne
- Center for Education and Research in Biomimetic Restorative Dentistry (CER BRD), Beverly Hills, CA, USA
| | - Marco M M Gresnigt
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; Martini Hospital, Department of Special Dental Care, Groningen, the Netherlands
| |
Collapse
|
7
|
Wang B, Fan J, Wang L, Xu B, Wang L, Chai L. Onlays/partial crowns versus full crowns in restoring posterior teeth: a systematic review and meta-analysis. Head Face Med 2022; 18:36. [PMID: 36411462 PMCID: PMC9677648 DOI: 10.1186/s13005-022-00337-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 10/20/2022] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Tooth-colored onlays and partial crowns for posterior teeth have been used increasingly in clinics. However, whether onlays/partial crowns could perform as well as full crowns in the posterior region was still not evaluated thoroughly. METHODS A literature search was conducted without language restrictions in Pubmed, Embase, Cochrane Central Register of Controlled Trial and Web of science until September 2021. RCTs, prospective and retrospective observational studies with a mean follow-up of 1 year were selected. Cochrane Collaboration's tool was adopted for quality assessment of the RCT. The quality of observational studies was evaluated following Newcastle-Ottawa scale. The random-effects and fixed-effects model were employed for meta-analysis. RESULTS Four thousand two hundred fifty-seven articles were initially searched. Finally, one RCT was identified for quality assessment and five observational studies for qualitative synthesis and meta-analysis. The RCT was of unclear risk of bias while five observational studies were evaluated as low risk. The meta-analysis indicated no statistically significant difference in the survival between onlays/partial crowns and full crowns after 1 year (OR = 0.55, 95% CI: 0.02-18.08; I2 = 57.0%; P = 0.127) and 3 years (OR = 0.65, 95% CI: 0.20-2.17; I2 = 0.0%; P = 0.747). For the success, onlays/partial crowns performed as well as crowns (OR = 0.58, 95% CI: 0.20-1.72; I2 = 0.0%; P = 0.881) at 3 years. No significant difference of crown fracture existed between the two methods (RD = 0.00, 95% CI: - 0.03-0.03; I2 = 0.0%; P = 0.972). CONCLUSIONS Tooth-colored onlays/partial crowns performed as excellently as full crowns in posterior region in a short-term period. The conclusions should be further consolidated by RCTs with long-term follow-up.
Collapse
Affiliation(s)
- Bingjie Wang
- grid.203507.30000 0000 8950 5267Department of Stomatology, The Affiliated People’s Hospital of Ningbo University (Ningbo Yinzhou People’s Hospital), No.251, Baizhang Road(E), Ningbo, 315000 China
| | - Jiayan Fan
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Lutao Wang
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Bin Xu
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Liang Wang
- grid.459833.00000 0004 1799 3336Department of Stomatology, Ningbo No.2 Hospital, Ningbo, 315000 China
| | - Luyi Chai
- grid.203507.30000 0000 8950 5267Department of Stomatology, The Affiliated People’s Hospital of Ningbo University (Ningbo Yinzhou People’s Hospital), No.251, Baizhang Road(E), Ningbo, 315000 China
| |
Collapse
|
8
|
Chen Y, Chen D, Ding H, Chen Q, Meng X. Fatigue behavior of endodontically treated maxillary premolars with MOD defects under different minimally invasive restorations. Clin Oral Investig 2021; 26:197-206. [PMID: 34031731 DOI: 10.1007/s00784-021-03991-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 05/14/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To analyze the stress distribution and subsequent fracture resistance of human maxillary premolars with mesial-occlusal-distal (MOD) defects restored with different minimally invasive restorations. MATERIALS AND METHODS Seventy non-carious human maxillary premolars were selected and divided into seven groups (n = 10). Ten teeth without further preparation served as control. The remaining teeth were endodontically treated and received three restorative patterns: inlays without cusp coverage (I), onlays with palatal coverage (O), overlays with both buccal and palatal coverage (Ov). Lithium disilicate glass ceramics (EM) and machinable composite resin (LU) were used for restoration. Specimens were tested under cycling loading with tongue direction of 45° for 1.2 × 106 cycles at a 50-N load and 2.0-Hz frequency. The survival time and two fracture mode classifications were assessed. Three-dimensional models of each group were designed. The magnitude and pattern of stresses were analyzed under the same condition of the in vitro test using finite element stress analysis. RESULTS Although the overlay model pattern produced more favorable stress distribution, three restorative patterns restored with the same material had no difference in survival curves (P > 0.05). Only the survival curve of the EM-Ov group had no statistical difference with that of the control group (P > 0.05). EM groups presented mainly interface adhesive failure, while LU groups were mainly material cohesive failure. CONCLUSION For the endodontically treated maxillary premolars with MOD defect, the lithium disilicate glass ceramic overlay pattern can reach the best restorative effect. CLINICAL RELEVANCE Comparing with restorative pattern, restorative material had a greater influence on the minimally invasive restoration of posterior teeth.
Collapse
Affiliation(s)
- Yani Chen
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China
| | - Du Chen
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China
| | - Hong Ding
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China
| | - Qiang Chen
- Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing, Jiangsu, China
| | - Xiangfeng Meng
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China.
| |
Collapse
|
9
|
Pilecco RO, Dalla-Nora F, Guilardi LF, Pereira GKR, de Andrade GS, de Melo RM, Valandro LF, Rippe MP. In-lab simulation of CAD/CAM milling of lithium disilicate glass-ceramic specimens: Effect on the fatigue behavior of the bonded ceramic. J Mech Behav Biomed Mater 2021; 121:104604. [PMID: 34087550 DOI: 10.1016/j.jmbbm.2021.104604] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/11/2021] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
The aim of this study was to evaluate the effect of in-lab simulation procedures performed on a lithium disilicate ceramic luted to a dentin-analogue material regarding the fatigue performance and topographic changes. Lithium disilicate ceramic (IPS e.max CAD) discs (Ø = 13.5 mm and 1.5 mm of thickness) were produced in different ways: milled in a CAD/CAM system (CAD/CAM - control group); mirror-polished (POL group); produced in-lab and ground with #60 silicon carbide paper (SiC group); with #60 wood sandpaper (WS group); with a fine diamond bur (DB group); or with a CAD/CAM bur adapted in a handpiece with a custom mandrel (MANDREL group). The ceramic discs were adhesively luted (Multilink N) onto dentin analogue discs (Ø = 12 mm and 2 mm of thickness) and fatigue testing (n = 19 discs) was performed by step-stress methodology (initial load of 200 N; step-size of 50 N; 10,000 cycles per step; 20 Hz). Surface roughness and contact angle analysis were also performed. According to Kaplan-Meier and post-hoc Mantel-Cox (log-rank), distinct fabrication methods affected the fatigue performance of bonded glass-ceramic discs (p< 0.001). The CAD/CAM group presented the lowest fatigue failure loads (1250 N) and number of cycles for failure (185,000), while the POL groups obtained the highest results (1752 N; 284,444 cycles). The in-lab groups had intermediate values (1355 - 1526 N; 206,052 - 238,684 cycles). Polished specimens presented the lowest roughness values (Ra = 0.041 μm), while the SiC (1.604 μm), WS (1.701 μm), and MANDREL (1.867 μm) groups showed statistically similar roughness values to the CAD/CAM group (1.738 μm). Despite differences before etching, the contact angle was similar among the milled and simulated groups after etching, except for the polished group. Even with some topographic similarities, the tested in-lab simulation methods were not able to mimic the milled specimens in terms of fatigue findings, leading to distinct magnitude of overestimations of the results.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Dalla-Nora
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luís Felipe Guilardi
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
10
|
Alassar R, Samy A, Abdel-Rahman F. Effect of cavity design and material type on fracture resistance and failure pattern of molars restored by computer-aided design/computer-aided manufacturing inlays/onlays. Dent Res J (Isfahan) 2021. [DOI: 10.4103/1735-3327.311421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
11
|
Kassis C, Khoury P, Mehanna CZ, Baba NZ, Bou Chebel F, Daou M, Hardan L. Effect of Inlays, Onlays and Endocrown Cavity Design Preparation on Fracture Resistance and Fracture Mode of Endodontically Treated Teeth: An In Vitro Study. J Prosthodont 2020; 30:625-631. [PMID: 33219727 DOI: 10.1111/jopr.13294] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/16/2020] [Indexed: 12/22/2022] Open
Abstract
PURPOSE To evaluate the fracture resistance and failure modes of endodontically treated mandibular molars restored with different designs of inlays, onlays and endocrowns. MATERIALS AND METHODS Extracted mandibular third molars (n = 180) were used. An access cavity was prepared on the occlusal surface of each tooth and the roots were obturated with gutta percha. All specimens were randomly divided into 6 groups (n = 30/group) according to the cavity design and the restoration material used. C: control group without access cavity preparation. IE: MOD inlay preparation with EverX Posterior (GC Europe) in the pulp chamber. IG: MOD inlay preparation with G-aenial Universal Flo (GC America) in the pulp chamber. OE: onlay preparation with EverX Posterior (GC Europe) in the pulp chamber. OG: onlay preparation with G-aenial Universal Flo (GC America) in the pulp chamber. EC: endocrown with an empty pulp chamber. All restorations were fabricated with CAD/CAM system using CERASMART® (GC Dental products Europe, Belgium) CAD/CAM blocks. Specimens were thermal-cycled and were subjected to a compressive load applied at 30° angle relative to the long axis of the tooth with a universal testing machine. Results were statistically analyzed by ANOVA followed by Tukey post hoc tests. Chi-square test and Fisher Exact tests were used for the comparisons among groups. RESULTS The mean fracture strength was significantly different between the groups (p < 0.001); it was significantly highest for intact teeth, followed by endocrowns (p = 0.021). The strength was significantly lower for inlays (with G-aenial Universal Flo and EverX Posterior), intermediate for onlays with EverX Posterior followed by onlays with G-aenial Universal Flo. CONCLUSIONS Endocrowns exhibited higher fracture resistance than other tested composite resin groups. Endocrowns and onlays showed a more favorable failure mode than inlay restorations.
Collapse
Affiliation(s)
- Cynthia Kassis
- Department of Esthetic and Restorative Dentistry, Saint-Joseph University, School of Dentistry, Beirut, Lebanon
| | - Pierre Khoury
- Department of Prosthodontics, Lebanese University, School of Dentistry, Beirut, Lebanon
| | - Carina Z Mehanna
- Department of Esthetic and Restorative Dentistry, Saint-Joseph University, School of Dentistry, Beirut, Lebanon
| | - Nadim Z Baba
- Advanced Education Program in Implant Dentistry, Loma Linda University, School of Dentistry, Loma Linda, CA
| | - Fadi Bou Chebel
- Esthetic and Restorative Dentistry, Saint-Joseph University, School of Dentistry, Beirut, Lebanon
| | - Maha Daou
- Dental Materials, Saint-Joseph University, School of Dentistry, Beirut, Lebanon
| | - Louis Hardan
- Esthetic and Restorative Dentistry, Saint-Joseph University, School of Dentistry, Beirut, Lebanon
| |
Collapse
|
12
|
Griffis E, Abd Alraheam I, Boushell L, Donovan T, Fasbinder D, Sulaiman TA. Tooth-cusp preservation with lithium disilicate onlay restorations: A fatigue resistance study. J ESTHET RESTOR DENT 2020; 34:512-518. [PMID: 33009726 DOI: 10.1111/jerd.12666] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 09/12/2020] [Accepted: 09/15/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVES This study examined the in vitro fatigue resistance of maxillary premolars with 2 mm or 3 mm preserved cusp thicknesses restored with lithium disilicate onlays. MATERIALS AND METHODS Premolars(N = 48) were divided into six groups. Onlays for groups 1 to 4 preserved a 3 mm functional (G1), 2 mm functional (G2), 3 mm nonfunctional (G3), or 2 mm nonfunctional (G4) buccal-lingual cusp width. Onlays for group 5 (G5, control) replaced both cusps. Group 6 (G6) samples were identical to G1 with added retentive boxes. Lithium disilicate onlays were exposed to thermocycling (10 000 cycles, 5°C-55°C, 30s/cycle) and mechanical loading (1.2 million cycles at 1.4 Hz and 70 N). All samples were examined for onlay debonding or cusp or onlay fracture. RESULTS Failure rates were 75%(G1), 0.0%(G2), 12.5%(G3), 0.0%(G4), 0.0%(G5), and 0.0%(G6). The difference in percent failure between the groups preserving the functional cusps (37.5%) and the groups preserving the nonfunctional cusps (6.3%) was statistically significant (P = .04; 95%CI:2.11-55.66). No cusp or restoration fractures were observed; all failures were due to debonding of the restoration. CONCLUSION Teeth with thin remaining cusps that were restored with bonded lithium disilicate onlay restorations were not prone to fracture. Retentive preparation features that physically eliminated lateral displacement prevented onlay debonding even though the ceramic-enamel margin was directly at the occlusal contact. CLINICAL SIGNIFICANCE The use of adhesively retained lithium disilicate ceramic onlays may be a viable alternative to full coverage restorations and may challenge traditionally accepted principals related to preparation resistance and retention form of ceramic partial coverage restorations.
Collapse
Affiliation(s)
| | | | - Lee Boushell
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of Chapel Hill, Chapel Hill, North Carolina, USA
| | - Terrence Donovan
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of Chapel Hill, Chapel Hill, North Carolina, USA
| | - Dennis Fasbinder
- Department of Cariology and Restorative Sciences and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA
| | - Taiseer A Sulaiman
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of Chapel Hill, Chapel Hill, North Carolina, USA
| |
Collapse
|
13
|
Huang X, Zou L, Yao R, Wu S, Li Y. Effect of preparation design on the fracture behavior of ceramic occlusal veneers in maxillary premolars. J Dent 2020; 97:103346. [PMID: 32325176 DOI: 10.1016/j.jdent.2020.103346] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 03/27/2020] [Accepted: 04/15/2020] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES The fracture strengths of four types of occlusal veneers and a traditional full crown ceramic restoration and the influence of preparation design on the stress of restorations were examined. METHODS Forty intact maxillary premolars randomly divided into five groups were prepared based on the demands of type O (occlusal surface coverage), OF (occlusal and lingual surface coverage), POF (occlusal, lingual, and mesial surface coverage), and POFP (occlusal, lingual, mesial, and distal surface coverage) veneers and full crown, and then restored by glass ceramic. Specimens were subjected to fracture resistance tests after cyclic loading. The fracture strengths and modes were analyzed statistically. The level of significance was set at α = 0.05. One maxillary premolar was prepared for type O, OF, POF, POFP veneer and full crown, and then scanned to establish finite element models. The mean fracture load was applied vertically to calculate the maximum principal stress on the ceramic. RESULTS Type O veneer showed higher fracture strength than type POF and POFP veneers (P < 0.05). Both type O and OF veneers exhibited higher fracture strength than full crown (P < 0.05). No significant difference in failure mode was observed. The maximum principal stress for type O, OF, POF, POFP veneers, and full crown increased progressively and concentrated at the bonding surface directly beneath the loading area. CONCLUSIONS Four types of occlusal veneer showed fracture strengths that considerably exceeded normal biting forces. They represent conservative alternatives to full crowns and present a viable treatment for severely worn teeth. CLINICAL SIGNIFICANCE The occlusal veneers with different preparation designs, including type O, OF, POF and POFP veneers, show higher fracture resistances than traditional full coverage crowns that considerably exceed the normal biting forces. Therefore, these represent conservative alternatives to crown restorations and present a viable treatment for restoring severely worn teeth.
Collapse
Affiliation(s)
- Xiaoqiong Huang
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Leiyan Zou
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Run Yao
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Shuyi Wu
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Yan Li
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| |
Collapse
|
14
|
Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis. J Clin Med 2019; 8:jcm8111932. [PMID: 31717610 PMCID: PMC6912690 DOI: 10.3390/jcm8111932] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 11/06/2019] [Accepted: 11/07/2019] [Indexed: 12/02/2022] Open
Abstract
Background: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. Materials and methods: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Results: Applying inclusion criteria based on the review’s population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Conclusions: Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.
Collapse
|