Prax M, McDonald CP, Bekeredjian-Ding I, Cloutier M, Gravemann U, Grothaus A, Krut O, Mpumlwana X, O'Flaherty N, Satake M, Stafford B, Suessner S, Vollmer T, Ramirez-Arcos S. Characterization of transfusion-relevant bacteria reference strains in a lyophilized format. Vox Sang 2024. [PMID: 38754952 DOI: 10.1111/vox.13654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 04/29/2024] [Accepted: 04/29/2024] [Indexed: 05/18/2024]
Abstract
BACKGROUND AND OBJECTIVES Blood safety measures used by blood establishments to increase blood component safety can be validated using Transfusion-Relevant Bacterial Reference Strains (TRBRS). Ultra-cold storage conditions and manual preparation of the current TRBRS may restrict their practical use. To address this issue, the ISBT Transfusion-Transmitted Infectious Diseases Working Party's Bacterial Subgroup organized an international study to validate TRBRS in a user-friendly, lyophilised format. MATERIALS AND METHODS Two bacterial strains Klebsiella pneumoniae PEI-B-P-08 and Staphylococcus aureus PEI-B-P-63 were manufactured as lyophilised material. The lyophilised bacteria were distributed to 11 different labs worldwide to assess the robustness for enumeration, identification and determination of growth kinetics in platelet concentrates (PCs). RESULTS Production of lyophilised TRBRS had no impact on the growth properties compared with the traditional format. The new format allows a direct low-quantity spiking of approximately 30 bacteria in PCs for transfusion-relevant experiments. In addition, the lyophilised bacteria exhibit long-term stability across a broad temperature range and can even be directly rehydrated in PCs without losing viability. Interlaboratory comparative study demonstrated the robustness of the new format as 100% of spiked PC exhibited growth. CONCLUSION Lyophilised TRBRS provide a user-friendly material for transfusion-related studies. TRBRS in the new format have improved features that may lead to a more frequent use in the quality control of transfusion-related safety measures in the future.
Collapse
Affiliation(s)
| | | | | | | | - Ute Gravemann
- German Red Cross Blood Service NSTOB, Springe, Germany
| | | | - Oleg Krut
- Paul-Ehrlich-Institut, Langen, Germany
| | - Xoliswa Mpumlwana
- Constantia Kloof, South African National Blood Service, Johannesburg, South Africa
| | | | | | | | - Susanne Suessner
- Red Cross Transfusion Service of Upper Austria, Austrian Red Cross, Linz, Austria
| | - Tanja Vollmer
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum NRW, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Sandra Ramirez-Arcos
- Innovation & Portfolio Management, Canadian Blood Services, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
2
|
Ramirez-Arcos S, Kumaran D, Cap A, Cardenas KM, Cloutier M, Ferdin J, Gravemann U, Ketter P, Landry P, Lu T, Niekerk T, Parker J, Renke C, Seltsam A, Stafford B, Süssner S, Vollmer T, Zilkenat S, McDonald C. Proliferation of psychrotrophic bacteria in cold-stored platelet concentrates. Vox Sang 2024. [PMID: 38631895 DOI: 10.1111/vox.13640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 04/03/2024] [Accepted: 04/04/2024] [Indexed: 04/19/2024]
Abstract
BACKGROUND AND OBJECTIVES Platelet concentrates (PC) are stored at 20-24°C to maintain platelet functionality, which may promote growth of contaminant bacteria. Alternatively, cold storage of PC limits bacterial growth; however, data related to proliferation of psychotrophic species in cold-stored PC (CSP) are scarce, which is addressed in this study. MATERIALS AND METHODS Eight laboratories participated in this study with a pool/split approach. Two split PC units were spiked with ~25 colony forming units (CFU)/PC of Staphylococcus aureus, Klebsiella pneumoniae, Serratia liquefaciens, Pseudomonas fluorescens and Listeria monocytogenes. One unit was stored under agitation at 20-24°C/7 days while the second was stored at 1-6°C/no agitation for 21 days. PC were sampled periodically to determine bacterial loads. Five laboratories repeated the study with PC inoculated with lyophilized inocula (~30 CFU/mL) of S. aureus and K. pneumoniae. RESULTS All species proliferated in PC stored at 20-24°C, reaching concentrations of ≤109 CFU/mL by day 7. Psychrotrophic P. fluorescens and S. liquefaciens proliferated in CSP to ~106 CFU/mL and ~105 CFU/mL on days 10 and 17 of storage, respectively, followed by L. monocytogenes, which reached ~102 CFU/mL on day 21. S. aureus and K. pneumoniae did not grow in CSP. CONCLUSION Psychrotrophic bacteria, which are relatively rare contaminants in PC, proliferated in CSP, with P. fluorescens reaching clinically significant levels (≥105 CFU/mL) before day 14 of storage. Cold storage reduces bacterial risk of PC to levels comparable with RBC units. Safety of CSP could be further improved by implementing bacterial detection systems or pathogen reduction technologies if storage is beyond 10 days.
Collapse
Affiliation(s)
- Sandra Ramirez-Arcos
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| | - Dilini Kumaran
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| | - Andrew Cap
- Coagulation and Blood Research Task Area US Army Institute of Surgical Research, Fort Sam Houston, Texas, USA
| | - Kristin Michelle Cardenas
- Coagulation and Blood Research Task Area US Army Institute of Surgical Research, Fort Sam Houston, Texas, USA
| | | | - Justin Ferdin
- Coagulation and Blood Research Task Area US Army Institute of Surgical Research, Fort Sam Houston, Texas, USA
| | - Ute Gravemann
- German Red Cross Blood Service NSTOB, Springe, Germany
| | - Patrick Ketter
- Coagulation and Blood Research Task Area US Army Institute of Surgical Research, Fort Sam Houston, Texas, USA
| | | | - Thea Lu
- Cerus Corporation, Concord, California, USA
| | - Truscha Niekerk
- South African National Blood Service, Roodepoort, South Africa
| | - Joel Parker
- Coagulation and Blood Research Task Area US Army Institute of Surgical Research, Fort Sam Houston, Texas, USA
| | - Claudia Renke
- Austrian Red Cross, Blood Centre Linz, Linz, Austria
| | - Axel Seltsam
- Bavarian Red Cross Blood Service, Nuremberg, Germany
| | | | | | - Tanja Vollmer
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum NRW, Universitätsklinikum der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | | | | |
Collapse
|
3
|
Kou Y, Kumaran D, Howell A, Ramirez-Arcos S. Comparable bacterial growth in platelet concentrates suspended in plasma and platelet additive solution and improved detection of bacterial contamination using a new generation automated culture system. Transfusion 2024; 64:665-673. [PMID: 38456520 DOI: 10.1111/trf.17772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 03/09/2024]
Abstract
BACKGROUND Microbial screening of platelet concentrates (PC) with automated culture methods is widely implemented to reduce septic transfusion reactions. Herein, detection of bacterial contamination in PC was compared between units prepared in plasma and a mix of plasma and platelet additive solution (PAS) and between the BACT/ALERT 3D and next generation BACT/ALERT VIRTUO systems. STUDY DESIGN/METHODS Double apheresis units were split into single units, diluted in either PAS (PAS-PC) or plasma (plasma-PC), and tested for in vitro quality and sterility prior to spiking with ~30 CFU/unit of Staphylococcus epidermidis, Staphylococcus aureus, Serratia marcescens, and Klebsiella pneumoniae or ~10 CFU/mL of Cutibacterium acnes. Spiked PC were sampled for BACT/ALERT testing (36 and 48 h post-spiking) and colony counts (24, 36, and 48 h post-spiking). Times to detection (TtoD) and bacterial loads were compared between PC products and BACT/ALERT systems (N = 3). RESULTS Bacterial growth was similar in plasma-PC and PAS-PC. No significant differences in TtoD were observed between plasma-PC and PAS-PC at the 36-h sampling time except for S. epidermidis which grew faster in plasma-PC and C. acnes which was detected earlier in PAS-PC (p < .05). Detection of facultative bacteria was 1.3-2.2 h sooner in VIRTUO compared with 3D (p < .05) while TtoD for C. acnes was not significantly different between the two systems. DISCUSSION Comparable bacterial detection was observed in plasma-PC and PAS-PC with PC sampling performed at 36-h post blood collection. PC sampling at ≤36 h could result in faster detection of facultative pathogenic organisms with the VIRTUO system and improved PC safety.
Collapse
Affiliation(s)
- Yuntong Kou
- Product & Process Development, Canadian Blood Services, Ottawa, Ontario, Canada
| | - Dilini Kumaran
- Product & Process Development, Canadian Blood Services, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| | - Anita Howell
- Product & Process Development, Canadian Blood Services, Ottawa, Ontario, Canada
| | - Sandra Ramirez-Arcos
- Product & Process Development, Canadian Blood Services, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
4
|
Gravemann U, Handke W, Schulze TJ, Seltsam A. Growth and Distribution of Bacteria in Contaminated Whole Blood and Derived Blood Components. Transfus Med Hemother 2024; 51:76-83. [PMID: 38584696 PMCID: PMC10996057 DOI: 10.1159/000536242] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 01/10/2024] [Indexed: 04/09/2024] Open
Abstract
Introduction Bacterial contamination of blood products presumably occurs mainly during blood collection, starting from low initial concentrations of 10-100 colony-forming units (CFUs) per bag. As little is known about bacterial growth behavior and distribution in stored whole blood (WB) and WB-derived blood products, this study aims to provide data on this subject. Methods WB units were inoculated with transfusion-relevant bacterial species (Acinetobacter baumannii, Bacillus cereus, Escherichia coli, Klebsiella pneumoniae, Listeria monocytogenes, Pseudomonas fluorescens, Serratia marcescens, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus dysgalactiae, Streptococcus pyogenes, Yersinia enterocolitica; n = 12 for each species), stored for 22-24 h at room temperature, and then centrifuged for separation into plasma, red blood cells (RBCs), and buffy coats (BCs). The latter were pooled with 3 random donor BCs and one unit of PAS-E each to yield plasma-reduced platelet concentrates (PCs). Samples for bacterial colony counting were collected after WB storage and immediately after blood component production. Sterility testing in PCs (n = 12 for each species) was performed by bacterial culture after 7 days of storage. Results Bacterial growth in WB varied remarkably between donations and species. Streptococcus species produced the highest titers in WB, whereas Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, and Pseudomonas fluorescens did not multiply. Centrifugation resulted in preferential accumulation of bacteria in BCs, with titers of up to 3.5 × 103 CFU/mL in BCs and up to ≤0.9 × 103 CFU/mL in BC-derived PCs. Overall, 72/144 PCs (50%) tested positive for bacteria after storage. Sterility test results were species-dependent, ranging from 12 of 12 PCs tested positive for Streptococcus pyogenes to 1 of 12 PCs positive for Escherichia coli. Bacterial contamination of RBC and plasma units was much less common and was associated with higher initial bacterial counts in the parent WB units. Conclusions Bacterial growth in WB is species-dependent and varies greatly between donations. Preferential accumulation of bacteria in BCs during manufacturing is a critical determinant of the contamination risk of BC-derived pooled PCs.
Collapse
Affiliation(s)
- Ute Gravemann
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Wiebke Handke
- Bavarian Red Cross Blood Service, Institute Nuremberg, Nuremberg, Germany
| | - Torsten J. Schulze
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Axel Seltsam
- Bavarian Red Cross Blood Service, Institute Nuremberg, Nuremberg, Germany
| |
Collapse
|
5
|
Salamanca-Pachon M, Guayacan-Fuquene NI, Garcia-Otalora MA. Septic Transfusion Reactions Involving Burkholderia cepacia Complex: A Review. Microorganisms 2023; 12:40. [PMID: 38257866 PMCID: PMC10818922 DOI: 10.3390/microorganisms12010040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/31/2023] [Accepted: 08/05/2023] [Indexed: 01/24/2024] Open
Abstract
This review was conducted to assess the global incidence of transfusion-transmitted infections (TTIs) caused by contamination of blood components with the Burkholderia cepacia complex (Bcc). Our search encompassed various specialized databases such as Medline/PubMed, Web of Science, Scopus, Scielo, ScienceDirect, and ClinicalKey. An analysis of the literature revealed a total of eleven reported cases where blood components contaminated with Bcc had been transfused, resulting in sepsis among the affected patients. Of these cases, eight were documented in the literature, while the remaining three occurred within the institution involving the authors of this review. A comparative examination was conducted, considering factors such as primary diagnosis, transfused blood component, time elapsed between transfusion and manifestation of symptoms, administration of antibiotics, and final outcome. Interestingly, regardless of the storage temperature, all blood components were found to be susceptible to Bcc contamination. Furthermore, the cases investigated revealed diverse sources of contamination, and it was observed that all the affected patients had compromised immune systems due to underlying illnesses. Based on these findings, a series of preventive strategies were derived to mitigate and decrease the occurrence of similar cases.
Collapse
Affiliation(s)
| | | | - Michel-Andres Garcia-Otalora
- Public Health Research Group, School of Medicine and Health Science, Universidad del Rosario, Bogotá 111221, Colombia;
| |
Collapse
|
6
|
Mpumlwana XL, Kruger W, Jentsch U. Establishment of a stable proficiency testing matrix in transfusion microbiology in South Africa. Afr J Lab Med 2023; 12:2095. [PMID: 38362035 PMCID: PMC10867670 DOI: 10.4102/ajlm.v12i1.2095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 06/13/2023] [Indexed: 02/17/2024] Open
Abstract
Background All medical laboratories must participate in proficiency testing (PT) programmes to ensure high-quality results. Proficiency testing samples mimic clinical samples; however, PT programmes for detection of bacteria in blood products are not routinely performed due to unavailability of matrix-equivalent samples. Objective The aim of this study was to develop and test a matrix-equivalent PT programme using blood products as the basis matrix. Methods A prospective cross-sectional study was conducted from April 2021 until June 2021, using 52 blood products comprising 36 pooled platelet and 16 red blood cell products at the South African National Blood Service PT laboratory in Gauteng. Products were manipulated into matrix-equivalent PT samples by spiking 42 products with known bacterial strains at specific concentrations and treating the remaining 10 products with preserving fluid containing antibiotics. The level of agreement between the researcher results and participating laboratories' results was assessed. Results Of the prepared matrices, 568 out of 572 (99%) were stable for 30 days. Bacteria could correctly be identified in spiked samples for up to 23 days. Samples treated with preserving fluid remained negative until day 30. For spiked samples, an average of 98% agreement (153/156) was achieved between the three participating laboratories when compared with the researcher's results; 100% agreement was achieved for unspiked samples. The kappa scores obtained from all tested variables presented with scores between 0.856 and 1.000, and the p-value was < 0.001 throughout. Conclusion The developed PT matrix was therefore stable and suitable to be implemented in transfusion microbiology. What this study adds This study demonstrated that a stable microbiology PT programme using platelets and red blood cells can be developed for use on bacterial detection analysers and could help to close the gap presented by unavailability of a blood PT matrix for transfusion microbiology.
Collapse
Affiliation(s)
- Xoliswa L Mpumlwana
- Department of Quality Control, South African National Blood Service, Roodepoort, South Africa
| | - Winnie Kruger
- Department of Biomedical Sciences, Faculty of Health Sciences, University of Johannesburg, Johannesburg, South Africa
| | - Ute Jentsch
- Department of Specialized Lab Services and Quality Control, South African National Blood Service, Roodepoort, South Africa
| |
Collapse
|
7
|
Kozakai M, Matsumoto M, Takakura A, Furuta RA, Matsubayashi K, Goto N, Satake M. Two cases of Streptococcus dysgalactiae subspecies equisimilis infection transmitted through transfusion of platelet concentrate derived from separate blood donations by the same donor. Vox Sang 2023. [PMID: 37191237 DOI: 10.1111/vox.13472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/04/2023] [Accepted: 05/05/2023] [Indexed: 05/17/2023]
Abstract
BACKGROUND Transfusion-transmitted bacterial infections (TTBIs) in Japan have been largely prevented due to a short shelf life of 3.5 days after blood collection for platelet concentrate (PC) and washed PCs (WPCs; PC in which 95% plasma is replaced by platelet additive solution). CASE PRESENTATION Case 1: In January 2018, a woman in her 50s with aplastic anaemia who received WPC transfusion and developed a fever the next day and Streptococcus dysgalactiae subspecies equisimilis (SDSE) was detected in the residual WPC. Case 2: In May 2018, a man in his 60s with a haematologic malignancy who received PC transfusion and developed chills during the transfusion. SDSE was detected in the patient's blood and residual PC. The contaminated platelet products were both manufactured from blood donated by the same donor. The multi-locus sequencing typing revealed that SDSE detected in case 1 was identical to that from case 2; however, whole blood subsequently obtained from the donor was culture negative. CONCLUSION WPC and PC produced from two blood donated 106 days apart by the same donor were contaminated with SDSE of the same strain and both caused TTBIs. Safety measures should be considered regarding blood collection from a donor with a history of bacterial contamination.
Collapse
Affiliation(s)
- Moe Kozakai
- Japanese Red Cross Society, Central Blood Institute, Tokyo, Japan
| | - Mami Matsumoto
- Japanese Red Cross Society, Central Blood Institute, Tokyo, Japan
| | - Akiko Takakura
- Japanese Red Cross Society, Central Blood Institute, Tokyo, Japan
| | - Rika A Furuta
- Japanese Red Cross Society, Central Blood Institute, Tokyo, Japan
| | | | - Naoko Goto
- Japanese Red Cross Society, Blood Service Headquarters, Tokyo, Japan
| | - Masahiro Satake
- Japanese Red Cross Society, Blood Service Headquarters, Tokyo, Japan
| |
Collapse
|
8
|
Handke W, Gravemann U, Müller TH, Wagner FF, Schulze TJ, Seltsam A. New ultraviolet C light-based method for pathogen inactivation of red blood cell units. Transfusion 2022; 62:2314-2323. [PMID: 36087025 DOI: 10.1111/trf.17098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 08/18/2022] [Accepted: 08/20/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Pathogen inactivation (PI) technologies for platelet concentrates and plasma are steadily becoming more established, but new PI treatment options for red blood cells (RBCs), the most commonly used blood component, still need to be developed. We present a novel approach to inactivating pathogens in RBC units employing ultraviolet C (UVC) light. METHODS Whole blood-derived leukoreduced RBCs suspended in PAGGS-C, a third generation additive solution, served as test samples, and RBCs in PAGGS-C or SAG-M as controls. Vigorous agitation and hematocrit reduction by diluting the RBCs with additional additive solution during illumination ensured that UVC light penetrated and inactivated the nine bacteria and eight virus species tested. Bacterial and viral infectivity assays and in vitro analyses were performed to evaluate the system's PI capacity and to measure the RBC quality, metabolic, functional, and blood group serological parameters of UVC-treated versus untreated RBCs during 36-day storage. RESULTS UVC treatment of RBCs in the PAGGS-C additive solution did not alter RBC antigen expression, but significantly influenced some in vitro parameters. Compared to controls, hemolysis was higher in UVC-treated RBC units, but was still below 0.8% at 36 days of storage. Extracellular potassium increased early after PI treatment and reached ≤70 mmol/L by the end of storage. UVC-treated RBC units had higher glucose and 2,3-diphosphoglycerate levels than controls. CONCLUSION As UVC irradiation efficiently reduces the infectivity of relevant bacteria and viruses while maintaining the quality of RBCs, the proposed method offers a new approach for PI of RBC concentrates.
Collapse
Affiliation(s)
- Wiebke Handke
- Bavarian Red Cross Blood Service, Nuremberg, Germany
| | - Ute Gravemann
- German Red Cross Blood Service NSTOB, Springe, Germany
| | | | | | | | - Axel Seltsam
- Bavarian Red Cross Blood Service, Nuremberg, Germany
| |
Collapse
|
9
|
Wang Y, Rao Q, Li X. Adverse transfusion reactions and what we can do. Expert Rev Hematol 2022; 15:711-726. [PMID: 35950450 DOI: 10.1080/17474086.2022.2112564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Transfusions of blood and blood components have inherent risks and the ensuing adverse reactions. It is very important to understand the adverse reactions of blood transfusion comprehensively for ensuring the safety of any future transfusions. AREAS COVERED According to the time of onset, adverse reactions of blood transfusion are divided into immediate and delayed transfusion reactions. In acute transfusion reactions, timely identification and immediate cessation of transfusion is critical. Vigilance is required to distinguish delayed responses or reactions that present non-specific signs and symptoms. In this review, we present the progress of mechanism, clinical characteristics and management of commonly encountered transfusion reactions. EXPERT OPINION The incidence of many transfusion-related adverse events is decreasing, but threats to transfusion safety are always emerging. It is particularly important for clinicians and blood transfusion staff to recognize the causes, symptoms and treatment methods of adverse blood transfusion reactions to improve the safety. In the future, at-risk patients will be better identified and can benefit from more closely matched blood components.
Collapse
Affiliation(s)
- Yajie Wang
- Department of Blood Transfusion, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Quan Rao
- Department of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Xiaofei Li
- Department of Blood Transfusion, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| |
Collapse
|
10
|
Schmidt M, Ramirez-Arcos S, Stiller L, McDonald C. Current status of rapid bacterial detection methods for platelet components: A 20-year review by the ISBT Transfusion-Transmitted Infectious Diseases Working Party Subgroup on Bacteria. Vox Sang 2022; 117:983-988. [PMID: 35412655 DOI: 10.1111/vox.13283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 01/17/2022] [Accepted: 02/10/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND OBJECTIVES Bacterial contamination of platelet components (PCs) poses a safety challenge for transfusion patients. Despite mitigation interventions, the residual risk of transfusion-transmitted bacterial infections remains predominant. PC safety can be improved either by pathogen reduction or by implementation of bacterial detection methods. Detection methodologies include culture methods and rapid detection methods. The current review focuses on currently available rapid detection methods. MATERIALS AND METHODS We reviewed published manuscripts since 2000 on rapid bacterial detection methods used for PC screening with result determination within 4 h. Methods meeting this criterion included Verax PGDprime, BacTx and nucleic amplification testing. The analytical and diagnostic sensitivity and specificity of these systems were assessed. RESULTS The analytical sensitivity between the different detection methods ranged between 50 and 100,000 CFU/ml. The sample volume used by these testing systems varies between 0.5 and 1.0 ml of PCs. A delay of at least 48 h before sampling enhances detectability. All rapid detection methods generate results in a timely manner, allowing testing to be performed before transfusion with optimal sensitivity. CONCLUSION Rapid detection methods improve PC safety regarding bacterial contamination. The assays are optimal for rapidly growing bacteria, which are more likely to cause septic transfusion reactions in patients. Because of the reduced diagnostic sensitivity, the sample collection should be late in shelf-life and ideally just before transfusion. The major benefit of these methods is that the test result can be obtained before releasing PCs for transfusion or to be used in combination with other screening methods applied early during PC storage.
Collapse
Affiliation(s)
| | - Sandra Ramirez-Arcos
- Department of Microbiology, Canadian Blood Services, Ottawa, Ontario, Canada.,Department of Microbiology, University of Ottawa, Ottawa, Ontario, Canada
| | - Lea Stiller
- German Red Cross, Institute Frankfurt, Frankfurt, Germany
| | | | | |
Collapse
|
11
|
Cloutier M, De Korte D. Residual risks of bacterial contamination for
pathogen‐reduced
platelet components. Vox Sang 2022; 117:879-886. [DOI: 10.1111/vox.13272] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 12/22/2021] [Accepted: 02/10/2022] [Indexed: 12/14/2022]
Affiliation(s)
- Marc Cloutier
- Medical Affairs and Innovation Héma‐Québec Québec Canada
- Biochemistry, Microbiology and Bio‐informatics Université Laval Québec Canada
| | - Dirk De Korte
- Blood Cell Research Sanquin Research Amsterdam The Netherlands
- Product and Process Development Sanquin Blood Bank Amsterdam The Netherlands
| | | |
Collapse
|
12
|
Arnason NA, Johannsson F, Landrö R, Hardarsson B, Gudmundsson S, Lian AM, Reseland J, Rolfsson O, Sigurjonsson OE. Protein Concentrations in Stored Pooled Platelet Concentrates Treated with Pathogen Inactivation by Amotosalen Plus Ultraviolet a Illumination. Pathogens 2022; 11:pathogens11030350. [PMID: 35335674 PMCID: PMC8954553 DOI: 10.3390/pathogens11030350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/10/2022] [Accepted: 03/11/2022] [Indexed: 02/04/2023] Open
Abstract
Platelet granules contain a diverse group of proteins. Upon activation and during storage, platelets release a number of proteins into the circulation or supernatant of stored platelet concentrate (PC). The aim of this work was to investigate the effect of pathogen inactivation (PI) on a selection of proteins released in stored platelets. Materials and Methods: PCs in platelet additive solution (PAS) were produced from whole blood donations using the buffy coat (BC) method. PCs in the treatment arm were pathogen inactivated with amotosalen and UVA, while PCs in the second arm were used as an untreated platelet control. Concentrations of 36 proteins were monitored in the PCs during storage. Results: The majority of proteins increased in concentration over the storage period. In addition, 10 of the 29 proteins that showed change had significantly different concentrations between the PI treatment and the control at one or more timepoints. A subset of six proteins displayed a PI-related drop in concentration. Conclusions: PI has limited effect on protein concentration stored PC supernatant. The protein’s changes related to PI treatment with elevated concentration implicate accelerated Platelet storage lesion (PSL); in contrast, there are potential novel benefits to PI related decrease in protein concentration that need further investigation.
Collapse
Affiliation(s)
- Niels Arni Arnason
- The Blood Bank, Landspitali-The National University Hospital of Iceland, 105 Reykjavik, Iceland; (N.A.A.); (R.L.); (B.H.); (S.G.)
- School of Engineering, Reykjavik University, 105 Reykjavik, Iceland
| | - Freyr Johannsson
- Department of Medicine, University of Iceland, 105 Reykjavik, Iceland; (F.J.); (O.R.)
| | - Ragna Landrö
- The Blood Bank, Landspitali-The National University Hospital of Iceland, 105 Reykjavik, Iceland; (N.A.A.); (R.L.); (B.H.); (S.G.)
| | - Björn Hardarsson
- The Blood Bank, Landspitali-The National University Hospital of Iceland, 105 Reykjavik, Iceland; (N.A.A.); (R.L.); (B.H.); (S.G.)
| | - Sveinn Gudmundsson
- The Blood Bank, Landspitali-The National University Hospital of Iceland, 105 Reykjavik, Iceland; (N.A.A.); (R.L.); (B.H.); (S.G.)
| | - Aina-Mari Lian
- Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, 0317 Oslo, Norway; (A.-M.L.); (J.R.)
| | - Janne Reseland
- Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, 0317 Oslo, Norway; (A.-M.L.); (J.R.)
| | - Ottar Rolfsson
- Department of Medicine, University of Iceland, 105 Reykjavik, Iceland; (F.J.); (O.R.)
| | - Olafur E. Sigurjonsson
- The Blood Bank, Landspitali-The National University Hospital of Iceland, 105 Reykjavik, Iceland; (N.A.A.); (R.L.); (B.H.); (S.G.)
- School of Engineering, Reykjavik University, 105 Reykjavik, Iceland
- Correspondence: ; Tel.: +354-543-5523 or +354-694-9427; Fax: +354-543-5532
| |
Collapse
|
13
|
Ramirez-Arcos S, Kou Y, Kumaran D, Culibrk B, Stewart T, Schubert P, McTaggart K. Assessment of bacterial growth in leukoreduced cold-stored whole blood supports overnight hold at room temperature prior to filtration: A pilot study. Vox Sang 2022; 117:678-684. [PMID: 35014042 DOI: 10.1111/vox.13246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/20/2021] [Accepted: 12/20/2021] [Indexed: 12/13/2022]
Abstract
BACKGROUND AND OBJECTIVES Whole blood (WB) transfusion has regained attention to treat trauma patients. We reported no significant changes in in vitro quality through 21 days of cold storage for leukoreduced WB (LCWB) when time to filtration was extended from 8 to 24 h from collection. This study evaluated the impact of extended WB-hold at room temperature (RT) prior to leukoreduction on proliferation of transfusion-relevant bacteria. MATERIALS AND METHODS WB units were spiked with suspensions of Klebsiella pneumoniae, Streptococcus pyogenes, Staphylococcus aureus and Listeria monocytogenes prepared in saline solution (SS) or trypticase soy broth (TSB) to a concentration of ~0.2 CFU/ml (N = 6). Spiked units were held at RT for 18-24 h before leukoreduction and cold-stored for 21 days. Bacterial growth was determined on days 2, 7, 14 and 21. In vitro quality of WB inoculated with unspiked diluents was assessed. RESULTS K. pneumoniae and S. pyogenes proliferated in WB prior to leukoreduction reaching concentrations ≤102 CFU/ml. These bacteria, however, did not proliferate during the subsequent cold storage. S. aureus did not survive in WB while L. monocytogenes reached a concentration of ~102 CFU/ml by day 21. LCWB in vitro quality was not affected by SS or TSB. CONCLUSION Extended WB-hold prior to leukoreduction allowed proliferation of bacteria able to resist immune clearance, although they did not grow to clinically significant levels. While L. monocytogenes proliferated in LCWB, clinically relevant concentrations were not reached by day 21. These data suggest that transfusing LCWB may not pose a significant bacterial contamination safety risk to transfusion patients.
Collapse
Affiliation(s)
- Sandra Ramirez-Arcos
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada.,Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| | - Yuntong Kou
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada
| | - Dilini Kumaran
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada.,Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| | - Brankica Culibrk
- Medical Affairs and Innovation, Canadian Blood Services, Vancouver, British Columbia, Canada
| | - Tamiko Stewart
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada
| | - Peter Schubert
- Medical Affairs and Innovation, Canadian Blood Services, Vancouver, British Columbia, Canada
| | - Ken McTaggart
- Medical Affairs and Innovation, Canadian Blood Services, Ottawa, Ontario, Canada
| |
Collapse
|
14
|
Brown BL, Wagner SJ, Hapip CA, Fischer E, Getz TM, Thompson-Montgomery D, Turgeon A. Time from apheresis platelet donation to cold storage: Evaluation of platelet quality and bacterial growth. Transfusion 2022; 62:439-447. [PMID: 34994468 DOI: 10.1111/trf.16785] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 12/06/2021] [Accepted: 12/06/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND Cold storage reduces posttransfusion survival of platelets; however, it can improve platelet activation, lower risk of bacterial contamination, and extend shelf-life compared to room temperature (RT) storage. To facilitate large-scale availability, manufacturing process optimization is needed, including understanding the impact of variables on platelet potency and safety. Short time requirements from collection to storage is challenging for large blood centers to complete resuspension and qualify platelets for production. This study evaluated the impact of time from platelet component collection to cold storage on in vitro properties and bacterial growth. STUDY DESIGN AND METHODS Double-apheresis platelet components were collected from healthy donors, suspended in 65% PAS-III/35% plasma, and split into 2 equal units. One unit was placed into cold storage within 2 h and the other unit after 8 h. Eight matched pairs were evaluated for 12 in vitro parameters. Twenty-four matched pairs were evaluated with 8 bacterial strains tested in triplicate. Samples were tested throughout 21 days of storage. RESULTS In vitro properties were not different between 2 and 8 h units, and trends throughout storage were similar between arms. Time to cold storage did not significantly impact bacterial growth, with <1 log10 difference at all timepoints between units. DISCUSSION Our studies showed that extending time to cold storage from 2 to 8 h from collection did not significantly increase the bacterial growth, and the platelet component quality and function is maintained. The ability to extend the time required from collection to storage will improve blood center logistics to feasibly produce CSPs.
Collapse
Affiliation(s)
- Bethany L Brown
- American Red Cross, Holland Lab for the Biomedical Sciences, Rockville, Maryland, USA
| | - Stephen J Wagner
- American Red Cross, Holland Lab for the Biomedical Sciences, Rockville, Maryland, USA
| | - C Anne Hapip
- American Red Cross, Holland Lab for the Biomedical Sciences, Rockville, Maryland, USA
| | - Erin Fischer
- American Red Cross, Holland Lab for the Biomedical Sciences, Rockville, Maryland, USA
| | - Todd M Getz
- U.S Army Medical Research and Development Command Battlefield Resuscitation for Immediate Stabilization of Combat Casualties Portfolio Combat Casualty Care Research Program Office, USA
| | | | - Annette Turgeon
- American Red Cross, Holland Lab for the Biomedical Sciences, Rockville, Maryland, USA
| |
Collapse
|
15
|
Prax M, Spindler-Raffel E, McDonald CP, Bearne J, Satake M, Kozakai M, Rojo J, Hanschmann KMO, Lambrecht B, Grundmann U, O'Flaherty N, Klimek A, Bekeredjian-Ding I, Gathof BS, Störmer M, Süßner S, Renke C, Lee CK, Knabbe C, Vollmer T, Keil SD, Shipps ME, Wagner SJ, Jentsch U, Mpumlwana X, Cloutier M, Bringmann P, Lu T, Ramirez-Arcos S, Kou Y, Krut O. Establishment of transfusion-relevant bacteria reference strains for red blood cells. Vox Sang 2020; 116:692-701. [PMID: 33341965 DOI: 10.1111/vox.13057] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 11/30/2022]
Abstract
BACKGROUND AND OBJECTIVES Red blood cell concentrates (RBCC) are susceptible to bacterial contamination despite cold storage. A reliable evaluation of strategies to minimize the risk of RBCC-associated bacterial transmission requires the use of suitable reference bacteria. Already existing Transfusion-Relevant Bacteria Reference Strains (TRBRS) for platelet concentrates fail to grow in RBCC. Consequently, the ISBT TTID, Working Party, Bacterial Subgroup, conducted an international study on TRBRS for RBCC. MATERIALS AND METHODS Six bacterial strains (Listeria monocytogenes PEI-A-199, Serratia liquefaciens PEI-A-184, Serratia marcescens PEI-B-P-56, Pseudomonas fluorescens PEI-B-P-77, Yersinia enterocolitica PEI-A-105, Yersinia enterocolitica PEI-A-176) were distributed to 15 laboratories worldwide for enumeration, identification, and determination of growth kinetics in RBCC at days 7, 14, 21, 28, 35 and 42 of storage after low-count spiking (10-25 CFU/RBCC). RESULTS Bacterial proliferation in RBCC was obtained for most strains, except for S. marcescens, which grew only at 4 of 15 laboratories. S. liquefaciens, S. marcescens, P. fluorescens and the two Y. enterocolitica strains reached the stationary phase between days 14 and 21 of RBCC storage with a bacterial concentration of approximately 109 CFU/ml. L. monocytogenes displayed slower growth kinetics reaching 106 -107 CFU/ml after 42 days. CONCLUSION The results illustrate the importance of conducting comprehensive studies to establish well-characterized reference strains, which can be a tool to assess strategies and methods used to ameliorate blood safety. The WHO Expert Committee on Biological Standardization adopted the five successful strains as official RBCC reference strains. Our study also highlights the relevance of visual inspection to interdict contaminated RBC units.
Collapse
Affiliation(s)
| | - Eva Spindler-Raffel
- Institut für Lebensmittelsicherheit/Food Safety, Hochschule, Geisenheim University, Geisenheim, Germany
| | | | | | | | | | - Julieta Rojo
- Centro Nacional de la Transfusión Sanguínea, Mexico, Mexico
| | | | | | - Udo Grundmann
- German Red Cross Blood Service NSTOB, Springe, Germany
| | | | - Agata Klimek
- Irish Blood Transfusion Service, Dublin, Ireland
| | | | - Birgit S Gathof
- Department of Transfusion Medicine, University Hospital of Cologne, Cologne, Germany
| | - Melanie Störmer
- Department of Transfusion Medicine, University Hospital of Cologne, Cologne, Germany
| | - Susanne Süßner
- Red Cross Transfusion Service of Upper Austria, Austrian Red Cross, Linz, Austria
| | - Claudia Renke
- Red Cross Transfusion Service of Upper Austria, Austrian Red Cross, Linz, Austria
| | - Cheuk-Kwong Lee
- Hong Kong Red Cross Blood Transfusion Service, Hong Kong, China
| | - Cornelius Knabbe
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum NRW, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Tanja Vollmer
- Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum NRW, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | | | | | - Stephen J Wagner
- Holland Laboratory, Transfusion Innovation Department, American Red Cross, Rockville, MD, USA
| | - Ute Jentsch
- Constantia Kloof, South African National Blood Service, Johannesburg, South Africa
| | - Xoliswa Mpumlwana
- Constantia Kloof, South African National Blood Service, Johannesburg, South Africa
| | | | | | - Thea Lu
- Cerus Corporation, Concord, CA, USA
| | - Sandra Ramirez-Arcos
- Canadian Blood Service, Ottawa, ON, Canada.,Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, ON, Canada
| | | | - Oleg Krut
- Paul-Ehrlich-Institut, Langen, Germany
| | | |
Collapse
|
16
|
Bolcato M, Russo M, Trentino K, Isbister J, Rodriguez D, Aprile A. Patient blood management: The best approach to transfusion medicine risk management. Transfus Apher Sci 2020; 59:102779. [DOI: 10.1016/j.transci.2020.102779] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 03/24/2020] [Accepted: 04/05/2020] [Indexed: 02/07/2023]
|
17
|
Abe H, Endo K, Shiba M, Niibe Y, Miyata S, Satake M. Flow path system of ultraviolet C irradiation from xenon flash to reduce bacteria survival in platelet products containing a platelet additive solution. Transfusion 2020; 60:1050-1059. [DOI: 10.1111/trf.15757] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 01/09/2020] [Accepted: 02/12/2020] [Indexed: 11/26/2022]
Affiliation(s)
- Hideki Abe
- Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society Tokyo Japan
| | - Kimika Endo
- Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society Tokyo Japan
| | - Masayuki Shiba
- Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society Tokyo Japan
| | | | - Shigeki Miyata
- Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society Tokyo Japan
| | - Masahiro Satake
- Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society Tokyo Japan
| |
Collapse
|
18
|
Arnason NA, Johannson F, Landrö R, Hardarsson B, Irsch J, Gudmundsson S, Rolfsson O, Sigurjonsson OE. Pathogen inactivation with amotosalen plus UVA illumination minimally impacts microRNA expression in platelets during storage under standard blood banking conditions. Transfusion 2019; 59:3727-3735. [PMID: 31674051 DOI: 10.1111/trf.15575] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 09/15/2019] [Accepted: 10/03/2019] [Indexed: 12/13/2022]
Abstract
BACKGROUND To reduce the risk of transfusion transmission infection, nucleic acid targeted methods have been developed to inactivate pathogens in PCs. miRNAs have been shown to play an important role in platelet function, and changes in the abundance of specific miRNAs during storage have been observed, as have perturbation effects related to pathogen inactivation (PI) methods. The aim of this work was to investigate the effects of PI on selected miRNAs during storage. STUDY DESIGN AND METHODS Using a pool and split strategy, 3 identical buffy coat PC units were generated from a pool of 24 whole blood donors. Each unit received a different treatment: 1) Untreated platelet control in platelet additive solution (C-PAS); 2) Amotosalen-UVA-treated platelets in PAS (PI-PAS); and 3) untreated platelets in donor plasma (U-PL). PCs were stored for 7 days under standard blood banking conditions. Standard platelet quality control (QC) parameters and 25 selected miRNAs were analyzed. RESULTS During the 7-day storage period, differences were found in several QC parameters relating to PI treatment and storage in plasma, but overall the three treatments were comparable. Out of 25 miRNA tested changes in regulation of 5 miRNA in PI-PAS and 3 miRNA U-PL where detected compared to C-PAS. A statistically significant difference was observed in down regulations miR-96-5p on Days 2 and 4, 61.9% and 61.8%, respectively, in the PI-PAS treatment. CONCLUSION Amotosalen-UVA treatment does not significantly alter the miRNA profile of platelet concentrates generated and stored using standard blood banking conditions.
Collapse
Affiliation(s)
- Niels Arni Arnason
- The Blood Bank, Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland
| | - Freyr Johannson
- Department of Medicine, University of Iceland, Reykjavik, Iceland
| | - Ragna Landrö
- The Blood Bank, Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland
| | - Björn Hardarsson
- The Blood Bank, Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland
| | | | - Sveinn Gudmundsson
- The Blood Bank, Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland
| | - Ottar Rolfsson
- Department of Medicine, University of Iceland, Reykjavik, Iceland
| | - Olafur E Sigurjonsson
- The Blood Bank, Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland.,School of Science and Engineering, Reykjavik University, Reykjavik, Iceland
| |
Collapse
|
19
|
Rebulla P. The long and winding road to pathogen reduction of platelets, red blood cells and whole blood. Br J Haematol 2019; 186:655-667. [PMID: 31304588 DOI: 10.1111/bjh.16093] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 06/22/2019] [Indexed: 02/07/2023]
Abstract
Pathogen reduction technologies (PRTs) have been developed to further reduce the current very low risks of acquiring transfusion-transmitted infections and promptly respond to emerging infectious threats. An entire portfolio of PRTs suitable for all blood components is not available, but the field is steadily progressing. While PRTs for plasma have been used for many years, PRTs for platelets, red blood cells (RBC) and whole blood (WB) were developed more slowly, due to difficulties in preserving cell functions during storage. Two commercial platelet PRTs use ultra violet (UV) A and UVB light in the presence of amotosalen or riboflavin to inactivate pathogens' nucleic acids, while a third experimental PRT uses UVC light only. Two PRTs for WB and RBC have been tested in experimental clinical trials with storage limited to 21 or 35 days, due to unacceptably high RBC storage lesion beyond these time limits. This review summarizes pre-clinical investigations and selected outcomes from clinical trials using the above PRTs. Further studies are warranted to decrease cell storage lesions after PRT treatment and to test PRTs in different medical and surgical conditions. Affordability remains a major administrative obstacle to PRT use, particularly so in geographical regions with higher risks of transfusion-transmissible infections.
Collapse
Affiliation(s)
- Paolo Rebulla
- Department of Transfusion Medicine and Haematology, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
20
|
Prax M, Bekeredjian-Ding I, Krut O. Microbiological Screening of Platelet Concentrates in Europe. Transfus Med Hemother 2019; 46:76-86. [PMID: 31191193 DOI: 10.1159/000499349] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 02/27/2019] [Indexed: 01/05/2023] Open
Abstract
The risk of transfusion-associated sepsis due to transmission of bacteria is a persistent problem in the transfusion field. Despite numerous interventions to reduce the risk, cases of bacterial sepsis following transfusion are repeatedly being reported. Especially platelet concentrates are highly susceptible to bacterial contaminations due to the growth-promoting storage conditions. In Europe, blood establishments and national authorities have implemented individual precaution measures to mitigate the risk of bacterial transmission. To obtain an overview of the different approaches, we compiled information from national authorities, blood establishments, and the current literature. Several aspects such as the shelf life of platelets, time of sampling and the applied control measures are compared between the member states. The analysis of the data revealed a broad heterogeneity of procedures on a national level ranging from platelet release without any safety testing up to mandatory screening of all platelet concentrates prior to transfusion. Despite the substantial progress made in recent years, several bacterial reports on transfusion-associated sepsis indicate that further efforts are needed to increase the safety of blood transfusions in the long term.
Collapse
Affiliation(s)
- Marcel Prax
- Division of Microbiology, Paul Ehrlich Institute, Langen, Germany
| | | | - Oleg Krut
- Division of Microbiology, Paul Ehrlich Institute, Langen, Germany
| |
Collapse
|
21
|
Ramirez‐Arcos S, McDonald C, Deol P, Kreuger AL, Patel N, Pidcoke H, Prax M, Seltsam A, Stassinopoulos A. Bacterial safety of blood components–a congress review of the ISBT transfusion‐transmitted infectious diseases working party, bacterial subgroup. ACTA ACUST UNITED AC 2019. [DOI: 10.1111/voxs.12483] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
| | | | | | | | | | | | | | - Axel Seltsam
- German Red Cross Blood Service NSTOB Springe Germany
| | | | | |
Collapse
|
22
|
Koutsoumanis K, Allende A, Álvarez-Ordóñez A, Bolton D, Bover-Cid S, Chemaly M, Davies R, Hilbert F, Lindqvist R, Nauta M, Peixe L, Ru G, Simmons M, Skandamis P, Suffredini E, Cocconcelli PS, Fernández Escámez PS, Maradona MP, Querol A, Suarez JE, Sundh I, Vlak J, Barizzone F, Correia S, Herman L. Update of the list of QPS-recommended biological agents intentionally added to food or feed as notified to EFSA 9: suitability of taxonomic units notified to EFSA until September 2018. EFSA J 2019; 17:e05555. [PMID: 32626100 PMCID: PMC7328880 DOI: 10.2903/j.efsa.2019.5555] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
The qualified presumption of safety (QPS) procedure was developed to provide a harmonised generic pre-evaluation to support safety risk assessments of biological agents performed by EFSA's Scientific Panels. The taxonomic identity, body of knowledge, safety concerns and antimicrobial resistance were assessed. Safety concerns identified for a taxonomic unit are, where possible and reasonable in number, reflected by 'qualifications' which should be assessed at the strain level by the EFSA's Scientific Panels. During the current assessment, no new information was found that would change the previously recommended QPS taxonomic units and their qualifications. Between April and September 2018, the QPS notification list was updated with 48 microorganisms from applications for market authorisation. Of these, 30 biological agents already had QPS status, 15 were excluded from the QPS exercise by the previous QPS mandate (five filamentous fungi) or from further evaluations within the current mandate (two notifications of Enterococcus faecium, one of Streptomyces spp. and seven of Escherichia coli). One taxonomic unit was (re)evaluated: Pseudomonas fluorescens had been previously evaluated in 2016, and was now re-evaluated within this mandate. The revision of the literature supports the previously identified safety concerns (e.g. production of biocompounds with antimicrobial activity and virulence features), preventing the inclusion of P. fluorescens in the QPS list. Mycobacterium setense and Komagataeibacter sucrofermentans were evaluated for the first time. M. setense cannot be considered for the QPS assessment because there are significant safety concerns. K. sucrofermentans (Acetobacter xylinus subsp. sucrofermentans) can be proposed for the QPS list but only for production purposes. The QPS status of Corynebacterium glutamicum is confirmed with the qualification extended to other production purposes.
Collapse
|
23
|
Gravemann U, Handke W, Müller TH, Seltsam A. Bacterial inactivation of platelet concentrates with the THERAFLEX UV-Platelets pathogen inactivation system. Transfusion 2018; 59:1324-1332. [PMID: 30588633 DOI: 10.1111/trf.15119] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 11/27/2018] [Accepted: 12/03/2018] [Indexed: 12/13/2022]
Abstract
BACKGROUND The THERAFLEX UV-Platelets system (Maco Pharma) uses ultraviolet C (UVC) light for pathogen inactivation (PI) of platelet concentrates (PCs) without any additional photoactive compound. The aim of the study was to systematically investigate bacterial inactivation with this system under conditions of intended use. STUDY DESIGN AND METHODS The robustness of the system was evaluated by assessing its capacity to inactivate high concentrations of different bacterial species in accordance with World Health Organization guidelines. The optimal use of the PI system was explored in time-to-treatment experiments by testing its ability to sterilize PCs contaminated with low levels of bacteria on the day of manufacture (target concentration, 100 colony-forming units/unit). The bacteria panel used for spiking experiments in this study included the World Health Organization International Repository Platelet Transfusion Relevant Reference Strains (n = 14), commercially available strains (n = 13), and in-house clinical isolates (n = 2). RESULTS Mean log reduction factors after UVC treatment ranged from 3.1 to 7.5 and varied between different strains of the same species. All PCs (n = 12/species) spiked with up to 200 colony-forming units/bag remained sterile until the end of storage when UVC treated 6 hours after spiking. UVC treatment 8 hours after spiking resulted in single breakthrough contaminations with the fast-growing species Escherichia coli and Streptococcus pyogenes. CONCLUSION The UVC-based THERAFLEX UV-Platelets system efficiently inactivates transfusion-relevant bacterial species in PCs. The comprehensive data from this study may provide a valuable basis for the optimal use of this UVC-based PI system.
Collapse
Affiliation(s)
- Ute Gravemann
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Wiebke Handke
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Thomas H Müller
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Axel Seltsam
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| |
Collapse
|
24
|
Levy JH, Neal MD, Herman JH. Bacterial contamination of platelets for transfusion: strategies for prevention. Crit Care 2018; 22:271. [PMID: 30367640 PMCID: PMC6204059 DOI: 10.1186/s13054-018-2212-9] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 09/25/2018] [Indexed: 01/07/2023]
Abstract
Platelet transfusions carry greater risks of infection, sepsis, and death than any other blood product, owing primarily to bacterial contamination. Many patients may be at particular risk, including critically ill patients in the intensive care unit. This narrative review provides an overview of the problem and an update on strategies for the prevention, detection, and reduction/inactivation of bacterial contaminants in platelets. Bacterial contamination and septic transfusion reactions are major sources of morbidity and mortality. Between 1:1000 and 1:2500 platelet units are bacterially contaminated. The skin bacterial microflora is a primary source of contamination, and enteric contaminants are rare but may be clinically devastating, while platelet storage conditions can support bacterial growth. Donor selection, blood diversion, and hemovigilance are effective but have limitations. Biofilm-producing species can adhere to biological and non-biological surfaces and evade detection. Primary bacterial culture testing of apheresis platelets is in routine use in the US. Pathogen reduction/inactivation technologies compatible with platelets use ultraviolet light-based mechanisms to target nucleic acids of contaminating bacteria and other pathogens. These methods have demonstrated safety and efficacy and represent a proactive approach for inactivating contaminants before transfusion to prevent transfusion-transmitted infections. One system, which combines ultraviolet A and amotosalen for broad-spectrum pathogen inactivation, is approved in both the US and Europe. Current US Food and Drug Administration recommendations advocate enhanced bacterial testing or pathogen reduction/inactivation strategies (or both) to further improve platelet safety. Risks of bacterial contamination of platelets and transfusion-transmitted infections have been significantly mitigated, but not eliminated, by improvements in prevention and detection strategies. Regulatory-approved technologies for pathogen reduction/inactivation have further enhanced the safety of platelet transfusions. Ongoing development of these technologies holds great promise.
Collapse
Affiliation(s)
- Jerrold H Levy
- Duke University Hospital, 2301 Erwin Road, Durham, NC, 27710, USA.
| | - Matthew D Neal
- University of Pittsburgh Medical Center, 200 Lothrop Street, Pittsburgh, PA, 15213, USA
| | - Jay H Herman
- Thomas Jefferson University Hospital, 111 S. 11th Street, Philadelphia, PA, 19107, USA
| |
Collapse
|
25
|
Störmer M, Wood EM, Gathof B. Microbial safety of cellular therapeutics-lessons from over ten years’ experience in microbial safety of platelet concentrates. ACTA ACUST UNITED AC 2018. [DOI: 10.1111/voxs.12452] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Melanie Störmer
- Transfusion Medicine; University Hospital Cologne; Cologne Germany
| | - Erica M. Wood
- Transfusion Research Unit; Department of Epidemiology and Preventive Medicine; Monash University; Melbourne VIC Australia
| | - Birgit Gathof
- Transfusion Medicine; University Hospital Cologne; Cologne Germany
| |
Collapse
|
26
|
|