1
|
Hayward S, Keogh PS, Miles AW, Gheduzzi S. The effect of structural changes on the low strain rate behaviour of the intervertebral disc. Proc Inst Mech Eng H 2024; 238:851-864. [PMID: 39180367 PMCID: PMC11459866 DOI: 10.1177/09544119241272915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 06/30/2024] [Indexed: 08/26/2024]
Abstract
The annuus fibrosus (AF) and nucleus pulposus (NP) of the intervertebral disc (IVD) work in conjunction to dissipate spinal loads. In this study we have isolated the contribution of the NP to the overall response of the disc and investigated the effect of extreme structural changes to the disc on the mechanical behaviour. Linear stiffness, overall load range, hysteresis area and total energy were used to evaluate the impact of these changes on the spine and surrounding structures. Six porcine lumbar isolated disc specimens were tested in 6 DOFs with a 400 N compressive axial preload at low strain rates in three conditions: intact (IN), after total nucleotomy (NN) and after the injection of bone cement into the nuclear void (SN). The latter two conditions, NN and SN, were chosen to emulate the effect of extreme changes to the NP on disc behaviour. When comparing with intact specimens, significant changes were noted primarily in axial compression-extension, mediolateral bending and flexion-extension. NN and SN cases demonstrated significant increases in linear stiffness, overall load range and total energy for mediolateral bending and flexion-extension compared to the intact (IN) state. SN also demonstrated a significant increase in total energy for axial compression-extension, and significant decreases in the elastic contribution to total energy in all axes except flexion-extension. These changes to total energy indicate that surrounding spinal structures would incur additional loading to produce the same motion in vivo after structural changes to the disc.
Collapse
Affiliation(s)
- Samantha Hayward
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Patrick S Keogh
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Anthony W Miles
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Sabina Gheduzzi
- Department of Mechanical Engineering, University of Bath, Bath, UK
| |
Collapse
|
2
|
Tavana S, Shek C, Rahman T, Baxan N, Newell N. The influence of geometry on intervertebral disc stiffness. J Biomech 2024; 163:111915. [PMID: 38233311 DOI: 10.1016/j.jbiomech.2023.111915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 12/05/2023] [Accepted: 12/31/2023] [Indexed: 01/19/2024]
Abstract
Geometry plays an important role in intervertebral disc (IVD) mechanics. Previous computational studies have found a link between IVD geometry and stiffness. However, few experimental studies have investigated this link, possibly due to difficulties in non-destructively quantifying internal geometric features. Recent advances in ultra-high resolution MRI provides the opportunity to visualise IVD features in unprecedented detail. This study aimed to quantify 3D human IVD geometries using 9.4 T MRIs and to investigate correlations between geometric variations and IVD stiffness. Thirty human lumbar motion segments (fourteen non-degenerate and sixteen degenerate) were scanned using a 9.4 T MRI and geometric parameters were measured. A 1kN compressive load was applied to each motion segment and stiffness was calculated. Degeneration caused a reduction (p < 0.05) in IVD height, a decreased nucleus-annulus area ratio, and a 1.6 ± 3.0 mm inward collapse of the inner annulus. The IVD height, anteroposterior (AP) width, lateral width, cross-sectional area, nucleus-annulus boundary curvature, and nucleus-annulus area ratio had a significant (p < 0.05) influence on IVD stiffness. Linear relationships (p < 0.05, r > 0.47) were observed between these geometric features and IVD compressive stiffness and a multivariate regression model was generated to enable stiffness to be predicted from features observable on clinical imaging (stiffness, N/mm = 6062 - (61.2 × AP width, mm) - (169.2 × IVD height, mm)). This study advances our understanding of disc structure-function relationships and how these change with degeneration, which can be used to both generate and validate more realistic computational models.
Collapse
Affiliation(s)
- S Tavana
- Department of Bioengineering, Imperial College London, London, UK
| | - C Shek
- Department of Bioengineering, Imperial College London, London, UK
| | - T Rahman
- Department of Bioengineering, Imperial College London, London, UK; Department of Mechanical Engineering, Imperial College London, UK
| | - N Baxan
- Biological Imaging Centre, Central Biomedical Services, Imperial College London, UK; National Heart and Lung Institute, Faculty of Medicine, Imperial College London, UK
| | - N Newell
- Department of Bioengineering, Imperial College London, London, UK.
| |
Collapse
|
3
|
Zhang C, Guo LX. Prediction of the biomechanical behaviour of the lumbar spine under multi-axis whole-body vibration using a whole-body finite element model. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3764. [PMID: 37539646 DOI: 10.1002/cnm.3764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 07/17/2023] [Accepted: 07/21/2023] [Indexed: 08/05/2023]
Abstract
Low back pain has been reported to have a high prevalence among occupational drivers. Whole-body vibration during the driving environment has been found to be a possible factor leading to low back pain. Vibration loads might lead to degeneration and herniation of the intervertebral disc, which would increase incidence of low back problems among drivers. Some previous studies have reported the effects of whole-body vibration on the human body, but studies on the internal dynamic responses of the lumbar spine under multi-axis vibration are limited. In this study, the internal biomechanical response of the intervertebral disc was extracted to investigate the biomechanical behaviour of the lumbar spine under a multi-axial vibration in a whole-body environment. A whole-body finite element model, including skin, soft tissues, the bone skeleton, internal organs and a detailed ligamentous lumbar spine, was used to provide a whole-body condition for analyses. The results showed that both vibrations close to vertical and fore-and-aft resonance frequencies would increase the transmission of vibrations in the intervertebral disc, and vertical vibration might have a greater effect on the lumbar spine than fore-and-aft vibration. The larger deformation of the posterior region of the intervertebral disc in a multi-axis vibration environment might contribute to the higher susceptibility of the posterior region of the intervertebral disc to injury. The findings of this study revealed the dynamic behaviours of the lumbar spine in multi-axis vehicle vibration conditions, and suggested that both vertical and fore-and-aft vibration should be considered for protecting the lumbar health of occupational drivers.
Collapse
Affiliation(s)
- Chi Zhang
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| |
Collapse
|
4
|
Rahman T, Tavana S, Baxan N, Raftery KA, Morgan G, Schaer TP, Smith N, Moore A, Bull J, Stevens MM, Newell N. Quantifying internal intervertebral disc strains to assess nucleus replacement device designs: a digital volume correlation and ultra-high-resolution MRI study. Front Bioeng Biotechnol 2023; 11:1229388. [PMID: 37849982 PMCID: PMC10577660 DOI: 10.3389/fbioe.2023.1229388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 09/15/2023] [Indexed: 10/19/2023] Open
Abstract
Introduction: Nucleus replacement has been proposed as a treatment to restore biomechanics and relieve pain in degenerate intervertebral discs (IVDs). Multiple nucleus replacement devices (NRDs) have been developed, however, none are currently used routinely in clinic. A better understanding of the interactions between NRDs and surrounding tissues may provide insight into the causes of implant failure and provide target properties for future NRD designs. The aim of this study was to non-invasively quantify 3D strains within the IVD through three stages of nucleus replacement surgery: intact, post-nuclectomy, and post-treatment. Methods: Digital volume correlation (DVC) combined with 9.4T MRI was used to measure strains in seven human cadaveric specimens (42 ± 18 years) when axially compressed to 1 kN. Nucleus material was removed from each specimen creating a cavity that was filled with a hydrogel-based NRD. Results: Nucleus removal led to loss of disc height (12.6 ± 4.4%, p = 0.004) which was restored post-treatment (within 5.3 ± 3.1% of the intact state, p > 0.05). Nuclectomy led to increased circumferential strains in the lateral annulus region compared to the intact state (-4.0 ± 3.4% vs. 1.7 ± 6.0%, p = 0.013), and increased maximum shear strains in the posterior annulus region (14.6 ± 1.7% vs. 19.4 ± 2.6%, p = 0.021). In both cases, the NRD was able to restore these strain values to their intact levels (p ≥ 0.192). Discussion: The ability of the NRD to restore IVD biomechanics and some strain types to intact state levels supports nucleus replacement surgery as a viable treatment option. The DVC-MRI method used in the present study could serve as a useful tool to assess future NRD designs to help improve performance in future clinical trials.
Collapse
Affiliation(s)
- Tamanna Rahman
- Department of Bioengineering, Imperial College London, London, United Kingdom
- Department of Mechanical Engineering, Biomechanics Group, Imperial College London, London, United Kingdom
| | - Saman Tavana
- Department of Bioengineering, Imperial College London, London, United Kingdom
- Department of Mechanical Engineering, Biomechanics Group, Imperial College London, London, United Kingdom
| | - Nicoleta Baxan
- Biological Imaging Centre, Central Biomedical Services, Imperial College London, London, United Kingdom
- Faculty of Medicine, National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Kay A. Raftery
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - George Morgan
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Thomas P. Schaer
- Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| | - Nigel Smith
- Division of Surgery and Interventional Science, University College London, Stanmore, United Kingdom
| | - Axel Moore
- Department of Bioengineering, Imperial College London, London, United Kingdom
- Department of Materials and Institute of Biomedical Engineering, Imperial College London, London, United Kingdom
| | - Jonathan Bull
- Neurosurgery, BARTS Health NHS Trust, London, United Kingdom
| | - Molly M. Stevens
- Department of Bioengineering, Imperial College London, London, United Kingdom
- Department of Materials and Institute of Biomedical Engineering, Imperial College London, London, United Kingdom
| | - Nicolas Newell
- Department of Bioengineering, Imperial College London, London, United Kingdom
| |
Collapse
|
5
|
Rahman T, Baxan N, Murray RT, Tavana S, Schaer TP, Smith N, Bull J, Newell N. An in vitro comparison of three nucleus pulposus removal techniques for partial intervertebral disc replacement: An ultra-high resolution MRI study. JOR Spine 2023; 6:e1232. [PMID: 37361334 PMCID: PMC10285766 DOI: 10.1002/jsp2.1232] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 10/03/2022] [Indexed: 10/19/2023] Open
Abstract
Background Nuclectomy, also known as nucleotomy, is a percutaneous surgical procedure performed to remove nucleus material from the center of the disc. Multiple techniques have been considered to perform a nuclectomy, however, the advantages and disadvantages of each are not well understood. Aims This in vitro biomechanical investigation on human cadaveric specimens aimed to quantitatively compare three nuclectomy techniques performed using an automated shaver, rongeurs, and laser. Material & Methods Comparisons were made in terms of mass, volume and location of material removal, changes in disc height, and stiffness. Fifteen vertebra-disc-vertebra lumbar specimens were acquired from six donors (40 ± 13 years) and split into three groups. Before and after nucleotomy axial mechanical tests were performed and T2-weighted 9.4T MRIs were acquired for each specimen. Results When using the automated shaver and rongeurs similar volumes of disc material were removed (2.51 ± 1.10% and 2.76 ± 1.39% of the total disc volume, respectively), while considerably less material was removed using the laser (0.12 ± 0.07%). Nuclectomy using the automated shaver and rongeurs significantly reduced the toe-region stiffness (p = 0.036), while the reduction in the linear region stiffness was significant only for the rongeurs group (p = 0.011). Post-nuclectomy, 60% of the rongeurs group specimens showed changes in the endplate profile while 40% from the laser group showed subchondral marrow changes. Discussion From the MRIs, homogeneous cavities were seen in the center of the disc when using the automated shaver. When using rongeurs, material was removed non-homogeneously both from the nucleus and annulus regions. Laser ablation formed small and localized cavities suggesting that the technique is not suitable to remove large volumes of material unless it is developed and optimized for this application. Conclusion The results demonstrate that both rongeurs and automated shavers can be used to remove large volumes of NP material but the reduced risk of collateral damage to surrounding tissues suggests that the automated shaver may be more suitable.
Collapse
Affiliation(s)
- Tamanna Rahman
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonLondonUK
- Department of BioengineeringImperial College LondonLondonUK
| | - Nicoleta Baxan
- Biological Imaging Centre, Central Biomedical ServicesImperial College London, Hammersmith Hospital CampusLondonUK
| | - Robert T. Murray
- Femtosecond Optics Group, Blackett Laboratory, Department of PhysicsImperial College LondonLondonUK
| | - Saman Tavana
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonLondonUK
- Department of BioengineeringImperial College LondonLondonUK
| | - Thomas P. Schaer
- Department of Clinical Studies, School of Veterinary Medicine, New Bolton CenterUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Nigel Smith
- Division of Surgery and Interventional ScienceUniversity College LondonStanmoreUK
| | - Jonathan Bull
- Department of NeurosurgeryBARTS Health NHS TrustLondonUK
| | - Nicolas Newell
- Department of BioengineeringImperial College LondonLondonUK
| |
Collapse
|
6
|
Liang T, Gao B, Zhou J, Qiu X, Qiu J, Chen T, Liang Y, Gao W, Qiu X, Lin Y. Constructing intervertebral disc degeneration animal model: A review of current models. Front Surg 2023; 9:1089244. [PMID: 36969323 PMCID: PMC10036602 DOI: 10.3389/fsurg.2022.1089244] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 12/08/2022] [Indexed: 03/12/2023] Open
Abstract
Low back pain is one of the top disorders that leads to disability and affects disability-adjusted life years (DALY) globally. Intervertebral disc degeneration (IDD) and subsequent discogenic pain composed major causes of low back pain. Recent studies have identified several important risk factors contributing to IDD's development, such as inflammation, mechanical imbalance, and aging. Based on these etiology findings, three categories of animal models for inducing IDD are developed: the damage-induced model, the mechanical model, and the spontaneous model. These models are essential measures in studying the natural history of IDD and finding the possible therapeutic target against IDD. In this review, we will discuss the technical details of these models, the duration between model establishment, the occurrence of observable degeneration, and the potential in different study ranges. In promoting future research for IDD, each animal model should examine its concordance with natural IDD pathogenesis in humans. We hope this review can enhance the understanding and proper use of multiple animal models, which may attract more attention to this disease and contribute to translation research.
Collapse
Affiliation(s)
- Tongzhou Liang
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Bo Gao
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Jinlang Zhou
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Xianjian Qiu
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Jincheng Qiu
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Taiqiu Chen
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yanfang Liang
- Department of Operating Theater, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Wenjie Gao
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Xuemei Qiu
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
- Correspondence: Xuemei Qiu Youxi Lin
| | - Youxi Lin
- Department of Orthopedic Surgery, Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, China
- Correspondence: Xuemei Qiu Youxi Lin
| |
Collapse
|