1
|
Jia Y, Han S, Li B, Liu C, Ta D. Backscatter measurement of cancellous bone using the ultrasound transit time spectroscopy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2670-2686. [PMID: 38639562 DOI: 10.1121/10.0025689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 03/26/2024] [Indexed: 04/20/2024]
Abstract
Recently, ultrasound transit time spectroscopy (UTTS) was proposed as a promising method for bone quantitative ultrasound measurement. Studies have showed that UTTS could estimate the bone volume fraction and other trabecular bone structure in ultrasonic through-transmission measurements. The goal of this study was to explore the feasibility of UTTS to be adapted in ultrasonic backscatter measurement and further evaluate the performance of backscattered ultrasound transit time spectrum (BS-UTTS) in the measurement of cancellous bone density and structure. First, taking ultrasonic attenuation into account, the concept of BS-UTTS was verified on ultrasonic backscatter signals simulated from a set of scatterers with different positions and intensities. Then, in vitro backscatter measurements were performed on 26 bovine cancellous bone specimens. After a logarithmic compression of the BS-UTTS, a linear fitting of the log-compressed BS-UTTS versus ultrasonic propagated distance was performed and the slope and intercept of the fitted line for BS-UTTS were determined. The associations between BS-UTTS parameters and cancellous bone features were analyzed using simple linear regression. The results showed that the BS-UTTS could make an accurate deconvolution of the backscatter signal and predict the position and intensity of the simulated scatterers eliminating phase interference, even the simulated backscatter signal was with a relatively low signal-to-noise ratio. With varied positions and intensities of the scatterers, the slope of the fitted line for the log-compressed BS-UTTS versus ultrasonic propagated distance (i.e., slope of BS-UTTS for short) yield a high agreement (r2 = 99.84%-99.96%) with ultrasonic attenuation in simulated backscatter signal. Compared with the high-density cancellous bone, the low-density specimen showed more abundant backscatter impulse response in the BS-UTTS. The slope of BS-UTTS yield a significant correlation with bone mineral density (r = 0.87; p < 0.001), BV/TV (r = 0.87; p < 0.001), and cancellous bone microstructures (r up to 0.87; p < 0.05). The intercept of BS-UTTS was also significantly correlated with bone densities (r = -0.87; p < 0.001) and trabecular structures (|r|=0.43-0.80; p < 0.05). However, the slope of the BS-UTTS underestimated attenuation when measurements were performed experimentally. In addition, a significant non-linear relationship was observed between the measured attenuation and the attenuation estimated by the slope of the BS-UTTS. This study demonstrated that the UTTS method could be adapted to ultrasonic backscatter measurement of cancellous bone. The derived slope and intercept of BS-UTTS could be used in the measurement of bone density and microstructure. The backscattered ultrasound transit time spectroscopy might have potential in the diagnosis of osteoporosis in the clinic.
Collapse
Affiliation(s)
- Yan Jia
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Shuai Han
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Boyi Li
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Chengcheng Liu
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
| | - Dean Ta
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China
| |
Collapse
|
2
|
Sadoughi S, Bevill G, Morgan EF, Palepu V, Keaveny TM, Wear KA. Biomechanical structure-function relations for human trabecular bone - comparison of calcaneus, femoral neck, greater trochanter, proximal tibia, and vertebra. Comput Methods Biomech Biomed Engin 2023; 26:508-516. [PMID: 35579530 PMCID: PMC9669279 DOI: 10.1080/10255842.2022.2069465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 04/04/2022] [Accepted: 04/20/2022] [Indexed: 11/03/2022]
Abstract
MicroCT-based finite element models were used to compute power law relations for uniaxial compressive yield stress versus bone volume fraction for 78 cores of human trabecular bone from five anatomic sites. The leading coefficient of the power law for calcaneus differed from those for most of the other sites (p < 0.05). However, after normalizing by site-specific mean values, neither the leading coefficient (p > 0.5) nor exponent (p > 0.5) differed among sites, suggesting that a given percentage deviation from mean bone volume fraction has the same mechanical consequence for all sites investigated. These findings help explain the success of calcaneal x-ray and ultrasound measurements for predicting hip fracture risk.
Collapse
Affiliation(s)
- Saghi Sadoughi
- Department of Mechanical Engineering, University of California, Berkeley, CA
| | - Grant Bevill
- Mechanical Engineering Department, University of North Florida, Jacksonville, FL
| | - Elise F Morgan
- Departments of Mechanical Engineering and Biomedical Engineering, Boston University, Boston, MA
| | - Vivek Palepu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California, Berkeley, CA
- Department of Bioengineering, University of California, Berkeley, CA
| | - Keith A Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| |
Collapse
|
3
|
Bi D, Shi L, Liu C, Li B, Li Y, Le LH, Luo J, Wang S, Ta D. Ultrasonic Through-Transmission Measurements of Human Musculoskeletal and Fat Properties. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:347-355. [PMID: 36266143 DOI: 10.1016/j.ultrasmedbio.2022.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 09/07/2022] [Accepted: 09/09/2022] [Indexed: 06/16/2023]
Abstract
The study described here was aimed at investigating the feasibility of using the ultrasonic through-transmission technique to estimate human musculoskeletal and fat properties. Five hundred eighty-two volunteers were assessed by dual-energy X-ray absorptiometry (DXA) and ultrasonic transmission techniques. Bone mineral density (BMD), muscle and fat mass were measured for both legs and the whole body. Hip BMD and spine BMD were also measured. Ultrasonic transmission measurements were performed on the heel, and the measured parameters were broadband ultrasound attenuation (BUA), speed of sound (SOS), ultrasonic stiffness index (SI), T-score and Z-score, which were significantly correlated with all measured BMDs. The optimal correlation was observed between SI and left-leg BMD (p < 0.001) before and after adjustment for age, sex and body mass index (BMI). The linear and partial correlation analyses revealed that BUA and SOS were closely associated with muscle and fat mass, respectively. Multiple regressions revealed that muscle and fat mass significantly contributed to the prediction of transmission parameters, explaining up to 17.83% (p < 0.001) variance independently of BMD. The results suggest that the ultrasonic through-transmission technique could help in the clinical diagnosis of skeletal and muscular system diseases.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Lingwei Shi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Jingchun Luo
- Human Phenome Institute, Fudan University, Shanghai, China
| | - Sijia Wang
- Shanghai Institute of Nutrition and Health, Chinese Academy of Sciences, Shanghai, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China; Human Phenome Institute, Fudan University, Shanghai, China.
| |
Collapse
|
4
|
Wear K. Scattering in Cancellous Bone. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:163-175. [DOI: 10.1007/978-3-030-91979-5_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
5
|
Ultrasonic Assessment of Cancellous Bone Based on the Two-Wave Phenomenon. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:119-143. [DOI: 10.1007/978-3-030-91979-5_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
Viano AM, Ankersen JP, Hoffmeister BK, Huang J, Fairbanks LC. Ultrasonic Bone Assessment: Ability of Apparent Backscatter Techniques to Detect Changes in the Microstructure of Human Cancellous Bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3309-3325. [PMID: 34138705 DOI: 10.1109/tuffc.2021.3090359] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Ultrasonic backscatter techniques may offer a useful approach for detecting changes in bone caused by osteoporosis. The goal of this study was to investigate how bone mineral density (BMD) and the microstructure of human cancellous bone affect three ultrasonic backscatter parameters that have been identified as potentially useful for ultrasonic bone assessment purposes: the apparent integrated backscatter (AIB), the frequency slope of apparent backscatter (FSAB), and the frequency intercept of apparent backscatter (FIAB). Ultrasonic measurements were performed with a 3.5-MHz broadband transducer on 54 specimens of human cancellous bone prepared from the proximal femur. Microstructural parameters and BMD were measured using X-ray microcomputed tomography (micro-CT). Relationships between AIB, FSAB, FIAB, and the micro-CT parameters were investigated using univariate and multivariate statistical analysis techniques. Moderate-to-strong univariate correlations were observed between the backscatter parameters and microstructure and BMD in many cases. The partial correlation analysis indicated that the backscatter parameters are dependent on microstructure independently of BMD in some cases. Multiple stepwise linear regression analysis used to generate multivariate models found that microstructure was a significant predictor of the backscatter parameters in most cases.
Collapse
|
7
|
Bi D, Dai Z, Liu D, Wu F, Liu C, Li Y, Li B, Li Z, Li Y, Ta D. Ultrasonic Backscatter Measurements of Human Cortical and Trabecular Bone Densities in a Head-Down Bed-Rest Study. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2404-2415. [PMID: 34052063 DOI: 10.1016/j.ultrasmedbio.2021.04.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 03/24/2021] [Accepted: 04/02/2021] [Indexed: 06/12/2023]
Abstract
This study aims to investigate the feasibility of quantitative ultrasonic backscatter in evaluating human cortical and trabecular bone densities in vivo based on a head-down-tilt bed rest study, with 36 participants tested through 90 d of bed rest and 180 d of recovery. Backscatter measurements were performed using an ultrasonic backscatter bone diagnostic instrument. Backscatter parameters were calculated with a dynamic signal-of-interest method, which was proposed to ensure the same ultrasonic interrogated volume in cortical and trabecular bones. The backscatter parameters exhibited significant correlations with site-matched bone densities provided by high-resolution peripheral quantitative computed tomography (0.33 < |R| < 0.72, p < 0.05). Some bone densities and backscatter parameters exhibited significant changes after the 90-d bed rest. The proposed method can be used to characterize bone densities, and the portable ultrasonic backscatter bone diagnostic device might be used to non-invasively reveal mean bone loss (across a group of people) after long-term bed rest and microgravity conditions of spaceflight missions.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Zhongquan Dai
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Duwei Liu
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Feng Wu
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Zhili Li
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Yinghui Li
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China.
| |
Collapse
|
8
|
Athanasios T, Konstantinos A, Despoina D. Three-dimensional-printed replica models of bone for experimentally decoupling trabecular bone properties contribution to ultrasound propagation parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:296. [PMID: 33514143 DOI: 10.1121/10.0003048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 12/11/2020] [Indexed: 06/12/2023]
Abstract
A detailed investigation of the relationship between ultrasonic (US) properties and trabecular bone microstructure is difficult because of the great variability in the bone loss process. The aim of this work was twofold. First, to verify by compressive tests that the three-dimensional (3D)-printer is able to produce precisely and repeatedly "bone replica models" of different size and density. Following, replicas of the original specimens with two different polymers and thinned trabeculae models were used to investigate US properties (speed of sound, SOS, and backscatter coefficient), aiming to deconvolute the influence of material properties on ultrasound characteristics. The results revealed that matrix material properties influence only the magnitude of the backscatter coefficient, whereas the characteristic undulated patterns are related to the trabecular structure. Simulation of perforation and thinning of cancellous bone, associated with bone loss, showed that SOS and mechanical properties were reduced perfectly linearly with apparent density when structure deteriorated. The 3D-printed bone replicas have the potential to enable systematic investigations of the influence of structure on both acoustical and mechanical properties and evaluate changes caused by bone loss. The development of replicas from materials with properties close to those of bone will permit quantitative conclusions for trabecular bone.
Collapse
Affiliation(s)
- Tsirigotis Athanasios
- Laboratory of Biomechanics and Biomedical Engineering, Department of Mechanical Engineering & Aeronautics, University of Patras, Rio, Greece
| | - Apostolopoulos Konstantinos
- Laboratory of Biomechanics and Biomedical Engineering, Department of Mechanical Engineering & Aeronautics, University of Patras, Rio, Greece
| | - Deligianni Despoina
- Laboratory of Biomechanics and Biomedical Engineering, Department of Mechanical Engineering & Aeronautics, University of Patras, Rio, Greece
| |
Collapse
|
9
|
Ichioka H, Miyamori D, Ishikawa N, Bandou R, Idota N, Kondou H, Ikegaya H. Estimation of Cadaveric Age by Ultrasonography. Diagnostics (Basel) 2020; 10:diagnostics10070499. [PMID: 32698432 PMCID: PMC7400501 DOI: 10.3390/diagnostics10070499] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/10/2020] [Accepted: 07/17/2020] [Indexed: 11/16/2022] Open
Abstract
(1) Background: While decreasing bone mineral density (BMD) with age in living people has been well documented, a correlation between age and bone mineral density in deceased people has only been reported in a few studies. A correlation between age and BMD in deceased people was investigated as an objective tool for age estimation of unidentified remains. (2) Methods: The Bone Area Ratio (BAR) was measured in 402 autopsy cases (143 females and 259 males over the age of 20). (3) Results: The correlation coefficient in the females was r = -0.5476, and the correlation coefficient in the males was r = -0.2166, indicating a stronger correlation in females than in males. A comparison of the BAR values in the deceased females for each age group with that in live females found no significant differences in the BAR values. BAR values in the deceased were similar to in live individuals, and this did not change with duration of the postmortem interval. (4) Conclusions: Measuring the BAR value based on bone mass using ultrasonic waves is rapid and easy, even for those lacking forensic training, and may be used to estimate the age of an individual and the likelihood of fracture due to trauma.
Collapse
Affiliation(s)
- Hiroaki Ichioka
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
| | - Daisuke Miyamori
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
- Department of General Internal Medicine, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima 734-8553, Japan
| | - Noboru Ishikawa
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
- Department of Forensic Odontology and Anthropology, Tokyo Dental College, 2-9-18 Misaki-cho, Chiyoda-ku, Tokyo 101-0061, Japan
| | - Risa Bandou
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
| | - Nozomi Idota
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
| | - Hiroki Kondou
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
| | - Hiroshi Ikegaya
- Department of Forensic Medicine, Graduate School of Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (H.I.); (D.M.); (N.I.); (R.B.); (N.I.); (H.K.)
- Correspondence: ; Tel.: +81-75-251-5343
| |
Collapse
|
10
|
Il Lee K. Relationships of the ultrasonic backscatter measurements with the bone mineral density and the microarchitectural parameters in bovine trabecular bone in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:EL51. [PMID: 32752773 DOI: 10.1121/10.0001605] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 07/01/2020] [Indexed: 06/11/2023]
Abstract
Relationships of the backscatter coefficient (BC), the apparent integrated backscatter (AIB), and the integrated reflection coefficient (IRC) with the bone mineral density (BMD) and the microarchitectural parameters were investigated in 28 bovine femoral trabecular bone samples. The BC was highly correlated with the BMD and the microarchitectural parameters (R = -0.66 to 0.71). In contrast, the AIB and the IRC exhibited high correlations with the BMD and the bone volume fraction (R = -0.68 to 0.77) and relatively lower correlations with the remaining microarchitectural parameters (R = -0.62 to 0.60). The multiple regression models yielded the adjusted squared correlation coefficients of 0.54-0.76.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of
| |
Collapse
|
11
|
A Combined Ultrasonic Backscatter Parameter for Bone Status Evaluation in Neonates. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2020; 2020:3187268. [PMID: 32411279 PMCID: PMC7211244 DOI: 10.1155/2020/3187268] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 03/30/2020] [Indexed: 11/18/2022]
Abstract
Metabolic bone disease (MBD) is one of the major complications of prematurity. Ultrasonic backscatter technique has the potential to be a portable and noninvasive method for early diagnosis of MBD. This study firstly applied CAS to neonates, which was defined as a linear combination of the apparent integrated backscatter coefficient (AIB) and spectral centroid shift (SCS). The objective was to evaluate the feasibility of ultrasonic backscatter technique for assessing neonatal bone health using AIB, SCS, and CAS. Ultrasonic backscatter measurements at 3.5 MHz, 5.0 MHz, and 7.5 MHz were performed on a total of 505 newborns within 48 hours after birth. The values of backscatter parameters were calculated and compared among gestational age groups. Correlations between backscatter parameters, gestational age, anthropometric indices, and biochemical markers were analyzed. The optimal predicting models for CAS were determined. The results showed term infants had lower SCS and higher AIB and CAS than preterm infants. Gestational age and anthropometric indices were negatively correlated with SCS (|r| = 0.45 – 0.57, P < 0.001), and positively correlated with AIB (|r| = 0.36 – 0.60, P < 0.001) and CAS (|r| = 0.56 – 0.69, P < 0.001). Biochemical markers yielded weak or nonsignificant correlations with backscatter parameters. CAS had relatively stronger correlations with the neonatal variables than AIB and SCS. At 3.5 MHz and 5.0 MHz, only gestational age (P < 0.001) independently contributed to the measurements of CAS, and could explain up to 40.5% – 44.3% of CAS variation. At 7.5 MHz, the combination of gestational age (P < 0.001), head circumference (P = 0.002), and serum calcium (P = 0.037) explained up to 40.3% of CAS variation. This study suggested ultrasonic backscatter technique was feasible to evaluate neonatal bone status. CAS was a promising parameter to provide more information about bone health than AIB or SCS alone.
Collapse
|
12
|
Du H, Yousefian O, Horn T, Muller M. Evaluation of Structural Anisotropy in a Porous Titanium Medium Mimicking Trabecular Bone Structure Using Mode-Converted Ultrasonic Scattering. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1017-1024. [PMID: 31940527 PMCID: PMC7301879 DOI: 10.1109/tuffc.2019.2963162] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The mode-converted (longitudinal to transverse, L-T) ultrasonic scattering method was utilized to characterize the structural anisotropy of a phantom mimicking the structural properties of trabecular bone. The sample was fabricated using metal additive manufacturing from high-resolution computed tomography (CT) images of a sample of trabecular horse bone with strong anisotropy. Two focused transducers were used to perform the L-T ultrasonic measurements. A normal incidence transducer was used to transmit longitudinal ultrasonic waves into the sample, while the scattered transverse signals were received by an oblique incidence transducer. At multiple locations on the sample, four L-T measurements were performed by collecting ultrasonic scattering from four directions. The amplitude of the root mean square (rms) of the collected ultrasonic scattering signals was calculated for each L-T measurement. The ratios of rms amplitudes for L-T measurements in different directions were calculated to characterize the anisotropy of sample. The results show that the amplitude of L-T converted scattering is highly dependent on the direction of microstructural anisotropy. A strong anisotropy of the microstructure was observed, which coincides with simulation results previously published on the same structure as well as with the anisotropy estimated from the CT images. These results suggest the potential of mode-converted ultrasonic scattering methods to assess the anisotropy of materials with porous, complex structures, including trabecular bone.
Collapse
Affiliation(s)
- Hualong Du
- Applied Research Associates, Inc. Littleton, CO, USA
| | - Omid Yousefian
- Center for Additive Manufacturing and Logistics, North Carolina State University, Raleigh, NC, USA
| | - Timothy Horn
- Industrial Engineering, North Carolina State University, Raleigh, NC, USA
- Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA
| | - Marie Muller
- Center for Additive Manufacturing and Logistics, North Carolina State University, Raleigh, NC, USA
| |
Collapse
|
13
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
14
|
Liu C, Li B, Li Y, Mao W, Chen C, Zhang R, Ta D. Ultrasonic Backscatter Difference Measurement of Bone Health in Preterm and Term Newborns. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:305-314. [PMID: 31791554 DOI: 10.1016/j.ultrasmedbio.2019.10.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 10/24/2019] [Accepted: 10/26/2019] [Indexed: 06/10/2023]
Abstract
Metabolic bone disease of prematurity remains a significant problem for preterm infants. Quantitative ultrasound (QUS) has potential as a non-invasive tool for assessing bone health of newborns. The aim of this study was to assess bone health in preterm and term newborns using ultrasonic backscatter difference measurement. This study analyzed a total of 493 neonates, including 239 full-term infants (gestational age [GA] >37 wk), 201 preterm I infants (GA: 32-37 wk) and 53 extreme preterm II infants (GA <32 wk). Ultrasonic backscatter measurements were performed on the calcaneus of infants at birth, and the normalized mean of the backscatter difference spectrum (nMBD) was calculated as an ultrasonic index of neonatal bone status. Simple and multiple linear regressions were performed to determine the association of ultrasonic nMBD with GA, anthropometric characteristics and biochemical markers. Statistically significant differences in GA, anthropometric characteristics (birth weight, birth length [BL], birth head circumference and body mass index [BMI]) and biochemical markers (alkaline phosphatase, serum calcium and serum phosphate) were observed among preterm and term infants. The nMBD for term infants (median = 3.72 dB/μs, interquartile range [IR] = 1.95 dB/μs) was significantly higher than that for preterm I infants (median = 1.95 dB/μs, IR = 3.12 dB/μs), which was, in turn, significantly higher than that for preterm II infants (median = 0.19 dB/μs, IR = 3.50 dB/μs). The nMBD yielded moderate correlations (ρ = 0.57-0.62, p < 0.001) with GA and anthropometric characteristics and weak correlations (|ρ| = 0.08-0.21, p < 0.001 or not significant) with biochemical markers. Multivariate regressions revealed that only BL (p = 0.002) and BMI (p = 0.032) yielded significantly independent contributions to the nMBD measurement, and combinations of BL and BMI could explain up to 42% of the variation of nMBD in newborn infants. This study found that ultrasonic backscatter difference measurement might be helpful in bone health evaluation in preterm and term newborns. The utility of ultrasonic backscatter measurement in diagnosis of metabolic bone disease in infants should be investigated further.
Collapse
Affiliation(s)
- Chengcheng Liu
- Institute of Acoustics, School of Physics Science and Engineering, Tongji University, Shanghai, China
| | - Boyi Li
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Ying Li
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Weiying Mao
- Department of Neonatology, Children's Hospital of Fudan University, Shanghai, China
| | - Chao Chen
- Department of Neonatology, Children's Hospital of Fudan University, Shanghai, China
| | - Rong Zhang
- Department of Neonatology, Children's Hospital of Fudan University, Shanghai, China.
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai, China; Academy for Engineering & Technology, Fudan University, Shanghai, China
| |
Collapse
|
15
|
Mohanty K, Yousefian O, Karbalaeisadegh Y, Ulrich M, Grimal Q, Muller M. Artificial neural network to estimate micro-architectural properties of cortical bone using ultrasonic attenuation: A 2-D numerical study. Comput Biol Med 2019; 114:103457. [PMID: 31600691 PMCID: PMC6817400 DOI: 10.1016/j.compbiomed.2019.103457] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 09/18/2019] [Accepted: 09/19/2019] [Indexed: 01/10/2023]
Abstract
The goal of this study is to estimate micro-architectural parameters of cortical porosity such as pore diameter (φ), pore density (ρ) and porosity (ν) of cortical bone from ultrasound frequency dependent attenuation using an artificial neural network (ANN). First, heterogeneous structures with controlled pore diameters and pore densities (mono-disperse) were generated, to mimic simplified structure of cortical bone. Then, more realistic structures were obtained from high resolution CT scans of human cortical bone. 2-D finite-difference time-domain simulations were conducted to calculate the frequency-dependent attenuation in the 1-8 MHz range. An ANN was then trained with the ultrasonic attenuation at different frequencies as the input feature vectors while the output was set as the micro-architectural parameters (pore diameter, pore density and porosity). The ANN is composed of three fully connected dense layers with 24, 12 and 6 neurons, connected to the output layer. The dataset was trained over 6000 epochs with a batch size of 16. The trained ANN exhibits the ability to predict the micro-architectural parameters with high accuracy and low losses. ANN approaches could potentially be used as a tool to help inform physics-based modelling of ultrasound propagation in complex media such as cortical bone. This will lead to the solution of inverse-problems to retrieve bone micro-architectural parameters from ultrasound measurements for the non-invasive diagnosis and monitoring osteoporosis.
Collapse
Affiliation(s)
- Kaustav Mohanty
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Omid Yousefian
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Yasamin Karbalaeisadegh
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Micah Ulrich
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| | - Quentin Grimal
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, 75006, Paris, France.
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
16
|
Mohanty K, Yousefian O, Karbalaeisadegh Y, Ulrich M, Muller M. Predicting Structural Properties of Cortical Bone by Combining Ultrasonic Attenuation and an Artificial Neural Network (ANN): 2-D FDTD Study. IMAGE ANALYSIS AND RECOGNITION: INTERNATIONAL CONFERENCE, ICIAR ... : PROCEEDINGS. ICIAR 2019; 11662:407-417. [PMID: 38288296 PMCID: PMC10823500 DOI: 10.1007/978-3-030-27202-9_37] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
The goal of this paper is to predict the micro-architectural parameters of cortical bone such as pore diameter ( ϕ ) and porosity ( v ) from ultrasound attenuation measurements using an artificial neural network (ANN). Slices from a 3-D CT scan of human femur are obtained. The micro-architectural parameters of porosity such as average pore size and porosity are calculated using image processing. When ultrasound waves propagate in porous structures, attenuation is observed due to scattering. Two-dimensional finite-difference time-domain simulations are carried out to obtain frequency dependent attenuation in those 2D structures. An artificial neural network (ANN) is then trained with the input feature vector as the frequency dependent attenuation and output as pore diameter ( ϕ ) and porosity ( v ) . The ANN is composed of one input layer, 3 hidden layers and one output layer, all of which are fully connected. 340 attenuation data sets were acquired and trained over 2000 epochs with a batch size of 32. Data was split into train, validation and test. It was observed that the ANN predicted the micro-architectural parameters of the cortical bone with high accuracies and low losses with a minimum R2 (goodness of fit) value of 0.95. ANN approaches could potentially help inform the solution of inverse-problems to retrieve bone porosity from ultrasound measurements. Ultimately, those inverse-problems could be used for the non-invasive diagnosis and monitoring of osteoporosis.
Collapse
Affiliation(s)
- Kaustav Mohanty
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, USA
| | - Omid Yousefian
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, USA
| | | | - Micah Ulrich
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, USA
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, NC State University, Raleigh, NC, USA
| |
Collapse
|
17
|
Lee KI. Correlations of the frequency dependence of the ultrasonic backscatter coefficient with the bone volume fraction and the trabecular thickness in bovine trabecular bone: Application of the binary mixture model. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:EL393. [PMID: 31153347 DOI: 10.1121/1.5107435] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 04/24/2019] [Indexed: 06/09/2023]
Abstract
The ultrasonic backscatter coefficient and the exponent n (frequency dependence of the backscatter coefficient) were measured in 24 bovine femoral trabecular bone samples. The binary mixture model for ultrasonic scattering from trabecular bone was applied to predict the variations of the ultrasound parameters with the bone volume fraction (BV/TV) and the trabecular thickness (Tb.Th) in trabecular bone. The backscatter coefficient exhibited significant, positive correlations with the BV/TV (R = 0.82) and the Tb.Th (R = 0.79). In contrast, the exponent n was found to be significantly, negatively correlated with the BV/TV (R = -0.77) and the Tb.Th, (R = -0.71).
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of
| |
Collapse
|
18
|
Tasinkevych Y, Falińska K, Lewin PA, Litniewski J. Improving broadband ultrasound attenuation assessment in cancellous bone by mitigating the influence of cortical bone: Phantom and in-vitro study. ULTRASONICS 2019; 94:382-390. [PMID: 30001852 DOI: 10.1016/j.ultras.2018.06.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 06/28/2018] [Accepted: 06/30/2018] [Indexed: 06/08/2023]
Abstract
The purpose of this work was to present a new approach that allows the influence of cortical bone on noninvasive measurement of broadband ultrasound attenuation (BUA) to be corrected. The method, implemented here at 1 MHz makes use of backscattered signal and once refined and clinically confirmed, it would offer an alternative to ionizing radiation based methods, such as DEXA (Dual-energy X-ray absorptiometry), quantitative computed tomography (QCT), radiographic absorptiometry (RA) or single X-ray absorptiometry (SXA), which are clinically approved for assessment of progress of osteoporosis. In addition, as the method employs reflected waves, it might substantially enhance the applicability of BUA - from being suitable to peripheral bones only it would extend this applicability to include such embedded bones as hip and femoral neck. The proposed approach allows the cortical layer parameters used for correction and the corrected value and parameter of the cancellous bone (BUA) to be determined simultaneously from the single (pulse-echo) bone backscattered wave; to the best of the authors' knowledge such approach was not previously reported. The validity of the method was tested using acoustic data obtained from a custom-designed bone-mimicking phantom and a calf femur. The relative error of the attenuation coefficient assessment was determined to be 3.9% and 4.7% for the bone phantom and calf bone specimens, respectively. When the cortical shell influence was not taken into account the corresponding errors were considerably higher 8.3% (artificial bone) and 9.2% (calf femur). As indicated above, once clinically proven, the use of this BUA measurement technique in reflection mode would augment diagnostic power of the attending physician by permitting to include bones, which are not accessible for transmission mode evaluation, e.g. hip, spine, humerus and femoral neck.
Collapse
Affiliation(s)
- Yuriy Tasinkevych
- Department of Ultrasound, Institute of Fundamental Technological Research of the Polish Academy of Sciences, Warsaw, Poland.
| | - Katarzyna Falińska
- Department of Ultrasound, Institute of Fundamental Technological Research of the Polish Academy of Sciences, Warsaw, Poland
| | | | - Jerzy Litniewski
- Department of Ultrasound, Institute of Fundamental Technological Research of the Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
19
|
Liu C, Li B, Diwu Q, Li Y, Zhang R, Ta D, Wang W. Relationships of Ultrasonic Backscatter With Bone Densities and Microstructure in Bovine Cancellous Bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2311-2321. [PMID: 30575524 DOI: 10.1109/tuffc.2018.2872084] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This study was designed to investigate the associations among ultrasonic backscatter, bone densities, and microstructure in bovine cancellous bone. Ultrasonic backscatter measurements were performed on 33 bovine cancellous bone specimens with a 2.25-MHz transducer. Ultrasonic apparent backscatter parameters ("apparent" means not compensating for ultrasonic attenuation and diffraction) were calculated with optimal signals of interest. The results showed that ultrasonic backscatter was significantly related to bone densities and microstructure ( R2 = 0.17 -0.88 and ). After adjusting the correlations by bone mineral density (BMD), the bone apparent density (BAD) and some trabecular structural features still contributed significantly to the adjusted correlations, with moderate additional variance explained ( ∆R2 = 9.7 % at best). Multiple linear regressions revealed that both BAD and trabecular structure contributed significantly and independently to the prediction of ultrasound backscatter (adjusted R2 = 0.75 -0.89 and ), explaining an additional 14% of the variance at most, compared with that of BMD measurements alone. The results proved that ultrasonic backscatter was primarily determined by BAD, not BMD, but the combination of bone structure and densities could achieve encouragingly better performances (89% of the variance explained at best) in predicting backscatter properties. This study demonstrated that ultrasonic apparent backscatter might provide additional density and structural features unrelated to current BMD measurement. Therefore, we suggest that ultrasonic backscatter measurement could play a more important role in cancellous bone evaluation.
Collapse
|
20
|
Lee KI. Velocity dispersion and backscatter in marrow-filled and water-filled trabecular bone samples in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:EL386. [PMID: 30522272 DOI: 10.1121/1.5077019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 10/22/2018] [Indexed: 06/09/2023]
Abstract
The phase velocity and the backscatter coefficient were measured in 28 bovine femoral trabecular bone samples filled with marrow and water in vitro from 0.2 to 0.6 MHz. The phase velocities decreased approximately linearly with increasing frequency and the average dispersion rate of -34 ms-1 MHz-1 in the marrow-filled samples was higher than that of -42 ms-1 MHz-1 in the water-filled samples. The backscatter coefficients exhibited nonlinear, monotonically increasing dependences on the frequency and the average value of the exponent n = 2.92 (frequency dependence) in the marrow-filled samples was higher than the value of n = 2.79 in the water-filled samples.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of Korea
| |
Collapse
|
21
|
Yousefian O, White RD, Karbalaeisadegh Y, Banks HT, Muller M. The effect of pore size and density on ultrasonic attenuation in porous structures with mono-disperse random pore distribution: A two-dimensional in-silico study. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:709. [PMID: 30180715 PMCID: PMC6093759 DOI: 10.1121/1.5049782] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Revised: 07/17/2018] [Accepted: 07/19/2018] [Indexed: 05/07/2023]
Abstract
This work proposes a power law model to describe the attenuation of ultrasonic waves in non-absorbing heterogeneous media with randomly distributed scatterers, mimicking a simplified structure of cortical bone. This paper models the propagation in heterogeneous structures with controlled porosity using a two-dimensional finite-difference time domain numerical simulation in order to measure the frequency dependent attenuation. The paper then fits a phenomenological model to the simulated frequency dependent attenuation by optimizing parameters under an ordinary least squares framework. Local sensitivity analysis is then performed on the resulting parameter estimates in order to determine to which estimates the model is most sensitive. This paper finds that the sensitivity of the model to various parameter estimates depends on the micro-architectural parameters, pore diameter (ϕ) and pore density (ρ). In order to get a sense for how confidently model parameters are able to be estimated, 95% confidence intervals for these estimates are calculated. In doing so, the ability to estimate model-sensitive parameters with a high degree of confidence is established. In the future, being able to accurately estimate model parameters from which micro-architectural ones could be inferred will allow pore density and diameter to be estimated via an inverse problem given real or simulated ultrasonic data to be determined.
Collapse
Affiliation(s)
- Omid Yousefian
- Mechanical and Aerospace Engineering Department, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| | - R D White
- Center for Research in Scientific Computation, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| | - Yasamin Karbalaeisadegh
- Mechanical and Aerospace Engineering Department, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| | - H T Banks
- Center for Research in Scientific Computation, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| | - Marie Muller
- Mechanical and Aerospace Engineering Department, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| |
Collapse
|
22
|
Hoffmeister BK, Viano AM, Huang J, Fairbanks LC, Ebron SC, Moore JT, Ankersen JP, Huber MT, Diaz AA. Ultrasonic backscatter difference measurements of cancellous bone from the human femur: Relation to bone mineral density and microstructure. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:3642. [PMID: 29960442 PMCID: PMC6014850 DOI: 10.1121/1.5043385] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 05/21/2018] [Accepted: 06/02/2018] [Indexed: 05/26/2023]
Abstract
Ultrasonic backscatter techniques are being developed to detect changes in cancellous bone caused by osteoporosis. One technique, called the backscatter difference technique, measures the power difference between two portions of a backscatter signal. The goal of the present study is to investigate how bone mineral density (BMD) and the microstructure of human cancellous bone influence four backscatter difference parameters: the normalized mean of the backscatter difference (nMBD) spectrum, the normalized slope of the backscatter difference spectrum, the normalized intercept of the backscatter difference spectrum, and the normalized backscatter amplitude ratio (nBAR). Ultrasonic measurements were performed with a 3.5 MHz broadband transducer on 54 specimens of human cancellous bone from the proximal femur. Volumetric BMD and the microstructural characteristics of the specimens were measured using x-ray micro-computed tomography. Of the four ultrasonic parameters studied, nMBD and nBAR demonstrated the strongest univariate correlations with density and microstructure. Multivariate analyses indicated that nMBD and nBAR depended on trabecular separation and possibly other microstructural characteristics of the specimens independently of BMD. These findings suggest that nMBD and nBAR may be sensitive to changes in the density and microstructure of bone caused by osteoporosis.
Collapse
Affiliation(s)
| | - Ann M Viano
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Jinsong Huang
- College of Medicine, University of Tennessee Health Science Center, Memphis, Tennessee 38163, USA
| | - Luke C Fairbanks
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Sheldon C Ebron
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Joshua T Moore
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Jordan P Ankersen
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Matthew T Huber
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Abel A Diaz
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| |
Collapse
|
23
|
A Cross-Sectional Study of the Association between Autoantibodies and Qualitative Ultrasound Index of Bone in an Elderly Sample without Clinical Autoimmune Disease. J Immunol Res 2018; 2018:9407971. [PMID: 29854851 PMCID: PMC5952466 DOI: 10.1155/2018/9407971] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 03/05/2018] [Accepted: 03/17/2018] [Indexed: 12/15/2022] Open
Abstract
Bone loss is characteristic of the ageing process and a common complication of many autoimmune diseases. Research has highlighted a potential role of autoantibodies in pathologic bone loss. The confounding effects of immunomodulatory drugs make it difficult to establish the contribution of autoantibodies amongst autoimmune disease sufferers. We attempted to examine the relationship between autoantibodies and bone mass in a population of 2812 elderly participants without clinical autoimmune disease. Serum samples were assayed for a panel of autoantibodies (anti-nuclear, extractable nuclear antigen, anti-neutrophil cytoplasmic, thyroid peroxidase, tissue transglutaminase, anti-cardiolipin, rheumatoid factor, and cyclic citrullinated peptide). Bone mass was measured using quantitative ultrasound (QUS) of the calcaneus. The relationship between each autoantibody and bone mass was determined using linear regression models. Anti-nuclear autoantibodies were the most prevalent, positive in approximately 11%, and borderline in roughly 23% of our sample. They were also the only autoantibody observed to be significantly associated with QUS index in the univariate analysis (n = 1628; r = -0.20; 95% CI: -0.40-0.00; p = 0.046). However, statistical significance was lost after adjustment for various other potential confounders. None of the other autoantibodies was associated with QUS index in either univariate or multivariate analysis. We are limited by the cross-sectional nature of the study and the low prevalence of autoantibodies in our nonclinical sample.
Collapse
|
24
|
Du H, Mohanty K, Muller M. Microstructural characterization of trabecular bone using ultrasonic backscattering and diffusion parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:EL445. [PMID: 28599551 PMCID: PMC6909975 DOI: 10.1121/1.4982824] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 04/13/2017] [Accepted: 04/14/2017] [Indexed: 05/28/2023]
Abstract
Finite differences time domain methods were utilized to simulate ultrasound propagation and scattering in anisotropic trabecular bone structures obtained from high resolution Computed Tomography (CT). The backscattered signals were collected and the incoherent contribution was extracted. The diffusion constant was calculated for propagations along and across the main direction of anisotropy, and was used to characterize the anisotropy of the trabecular microstructures. In anisotropic structures, the diffusion constant was significantly different in both directions, and the anisotropy of the diffusion constant was strongly correlated to the structural anisotropy measured on the CT images. These results indicate that metrics based on diffusion can be used to quantify the anisotropy of complex structures such as trabecular bone.
Collapse
Affiliation(s)
- Hualong Du
- Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, USA , ,
| | - Kaustav Mohanty
- Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, USA , ,
| | - Marie Muller
- Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, USA , ,
| |
Collapse
|
25
|
Xu Y, Xu Y, Ding Z, Chen Y, Su B, Ma Z, Sun YN. Correlation between ultrasonic power spectrum and bone density on the heel. ULTRASONICS 2017; 73:77-81. [PMID: 27614335 DOI: 10.1016/j.ultras.2016.08.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2016] [Revised: 08/29/2016] [Accepted: 08/30/2016] [Indexed: 06/06/2023]
Abstract
The purposes of this paper were to evaluate the correlation between ultrasonic power spectrum and bone density and to extract the effectiveness of parameters from power spectrum for evaluating bone density. A total of 50 persons 24-72years of age were recruited. All study participants underwent bone mineral density (BMD) measurements of the lumbar spine (vertebral levels L1-L4). The participants also underwent calcaneal measurements to determine ultrasonic power spectrum with central frequencies of 0.5MHz. Three parameters from normalized power spectrum, called principle frequency (PF), frequency band (FB), and amplitude for principle frequency (APF), were chosen and be evaluated the correlation with the lumbar spine BMD. The correlation coefficient of PF, FB and APF with BMD was r=-0.48 (p<0.001), r=0.48 (p<0.001), and r=-0.71 (p<0.001), respectively. The results showed that the correlation between APF and BMD was better than the correlation among PF, FB and BMD, and APF have a significant correlation with BMD. In conclusion, the correlations among the parameters of ultrasonic power spectrum and BMD are significant, and especially APF performs better than PF and FB in evaluating bone density of participants. These results suggest that ultrasonic power spectrum may contain substantial information not already contained in BUA and SOS. A multiple regression model including all three QUS variables was somewhat more predictive of BMD than a model including only BUA and SOS.
Collapse
Affiliation(s)
- Yubing Xu
- Institute and Intelligent of Machines, Chinese Academy of Science, Hefei, Anhui, PR China
| | - Yang Xu
- Institute and Intelligent of Machines, Chinese Academy of Science, Hefei, Anhui, PR China; Department of Automation, University of Science and Technology of China, Hefei, Anhui, PR China
| | - Zenghui Ding
- Institute and Intelligent of Machines, Chinese Academy of Science, Hefei, Anhui, PR China; Department of Automation, University of Science and Technology of China, Hefei, Anhui, PR China
| | - Yanyan Chen
- Institute and Intelligent of Machines, Chinese Academy of Science, Hefei, Anhui, PR China.
| | - Benyue Su
- School of Mathematics and Computing Science, Anqing Teachers College, PR China
| | - Zuchang Ma
- Institute and Intelligent of Machines, Chinese Academy of Science, Hefei, Anhui, PR China
| | - Yi-Ning Sun
- Institute and Intelligent of Machines, Chinese Academy of Science, Hefei, Anhui, PR China
| |
Collapse
|
26
|
Lee KI. Relationships of linear and nonlinear ultrasound parameters with porosity and trabecular spacing in trabecular-bone-mimicking phantoms. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:EL528. [PMID: 28040043 DOI: 10.1121/1.4972530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The speed of sound (SOS), the normalized broadband ultrasound attenuation (nBUA), and the nonlinear parameter (B/A) were measured in 18 trabecular-bone-mimicking phantoms consisting of water-saturated aluminum foams. The strong slow wave and the very weak fast wave were consistently observed in the signals transmitted through all of the phantoms. It was found that the SOS increased as the porosity and the trabecular spacing increased. In contrast, both the nBUA and the B/A showed opposite dependences on the porosity and the trabecular spacing. All three ultrasound parameters exhibited high correlation coefficients with the porosity and the trabecular spacing.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of Korea
| |
Collapse
|
27
|
Wille ML, Langton CM. Solid volume fraction estimation of bone:marrow replica models using ultrasound transit time spectroscopy. ULTRASONICS 2016; 65:329-337. [PMID: 26455950 DOI: 10.1016/j.ultras.2015.09.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 08/31/2015] [Accepted: 09/15/2015] [Indexed: 06/05/2023]
Abstract
The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagation in cancellous bone may be described by a concept of parallel sonic rays; the transit time of each ray defined by the proportion of bone and marrow propagated. A Transit Time Spectrum (TTS) describes the proportion of sonic rays having a particular transit time, effectively describing the lateral inhomogeneity of transit times over the surface aperture of the receive ultrasound transducer. The aim of this study was to test the hypothesis that the solid volume fraction (SVF) of simplified bone:marrow replica models may be reliably estimated from the corresponding ultrasound transit time spectrum. Transit time spectra were derived via digital deconvolution of the experimentally measured input and output ultrasonic signals, and compared to predicted TTS based on the parallel sonic ray concept, demonstrating agreement in both position and amplitude of spectral peaks. Solid volume fraction was calculated from the TTS; agreement between true (geometric calculation) with predicted (computer simulation) and experimentally-derived values were R(2)=99.9% and R(2)=97.3% respectively. It is therefore envisaged that ultrasound transit time spectroscopy (UTTS) offers the potential to reliably estimate bone mineral density and hence the established T-score parameter for clinical osteoporosis assessment.
Collapse
Affiliation(s)
- Marie-Luise Wille
- Biomedical Engineering & Medical Physics Discipline, Science & Engineering Faculty and Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia.
| | - Christian M Langton
- Biomedical Engineering & Medical Physics Discipline, Science & Engineering Faculty and Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
28
|
Correlation between the combination of apparent integrated backscatter–spectral centroid shift and bone mineral density. J Med Ultrason (2001) 2016; 43:167-73. [DOI: 10.1007/s10396-015-0690-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Accepted: 11/11/2015] [Indexed: 10/22/2022]
|
29
|
Hoffmeister BK, Mcpherson JA, Smathers MR, Spinolo PL, Sellers ME. Ultrasonic backscatter from cancellous bone: the apparent backscatter transfer function. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:2115-25. [PMID: 26683412 DOI: 10.1109/tuffc.2015.007299] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Ultrasonic backscatter techniques are being developed to detect changes in cancellous bone caused by osteoporosis. Many techniques are based on measurements of the apparent backscatter transfer function (ABTF), which represents the backscattered power from bone corrected for the frequency response of the measurement system. The ABTF is determined from a portion of the backscatter signal selected by an analysis gate of width τw delayed by an amount τd from the start of the signal. The goal of this study was to characterize the ABTF for a wide range of gate delays (1 μs ≤ τd ≤ 6 μs) and gate widths (1 μs ≤ τw ≤ 6 μs). Measurements were performed on 29 specimens of human cancellous bone in the frequency range 1.5 to 6.0 MHz using a broadband 5-MHz transducer. The ABTF was found to be an approximately linear function of frequency for most choices of τd and τw. Changes in τd and τw caused the frequency-averaged ABTF [quantified by apparent integrated backscatter (AIB)] and the frequency dependence of the ABTF [quantified by frequency slope of apparent backscatter (FSAB)] to change by as much as 24.6 dB and 6.7 dB/MHz, respectively. τd strongly influenced the measured values of AIB and FSAB and the correlation of AIB with bone density (-0.95 ≤ R ≤ +0.68). The correlation of FSAB with bone density was influenced less strongly by τd (-0.97 ≤ R ≤ -0.87). τw had a weaker influence than τd on the measured values of AIB and FSAB and the correlation of these parameters with bone density.
Collapse
|
30
|
Casciaro S, Conversano F, Pisani P, Muratore M. New perspectives in echographic diagnosis of osteoporosis on hip and spine. ACTA ACUST UNITED AC 2015; 12:142-50. [PMID: 26604940 DOI: 10.11138/ccmbm/2015.12.2.142] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Currently, the accepted "gold standard" method for bone mineral density (BMD) measurement and osteoporosis diagnosis is dual-energy X-ray absorptiometry (DXA). However, actual DXA effectiveness is limited by several factors, including intrinsic accuracy uncertainties and possible errors in patient positioning and/or post-acquisition data analysis. DXA employment is also restricted by the typical issues related to ionizing radiation employment (high costs, need of dedicated structures and certified operators, unsuitability for population screenings). The only commercially-available alternative to DXA is represented by "quantitative ultrasound" (QUS) approaches, which are radiation-free, cheaper and portable, but they cannot be applied on the reference anatomical sites (lumbar spine and proximal femur). Therefore, their documented clinical usefulness is restricted to calcaneal applications on elderly patients (aged over 65 y), in combination with clinical risk factors and only for the identification of healthy subjects at low fracture risk. Literature-reported studies performed some QUS measurements on proximal femur, but their clinical translation is mostly hindered by intrinsic factors (e.g., device bulkiness). An innovative ultrasound methodology has been recently introduced, which performs a combined analysis of B-mode images and corresponding "raw" radiofrequency signals acquired during an echographic scan of the target reference anatomical site, providing two novel parameters: Osteoporosis Score and Fragility Score, indicative of BMD level and bone strength, respectively. This article will provide a brief review of the available systems for osteoporosis diagnosis in clinical routine contexts, followed by a synthesis of the most promising research results on the latest ultrasound developments for early osteoporosis diagnosis and fracture prevention.
Collapse
Affiliation(s)
- Sergio Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | | | - Paola Pisani
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - Maurizio Muratore
- OU of Rheumatology, "Galateo" Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy
| |
Collapse
|
31
|
Hoffmeister BK, Spinolo PL, Sellers ME, Marshall PL, Viano AM, Lee SR. Effect of intervening tissues on ultrasonic backscatter measurements of bone: An in vitro study. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:2449-57. [PMID: 26520327 PMCID: PMC4627934 DOI: 10.1121/1.4931906] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 09/07/2015] [Accepted: 09/12/2015] [Indexed: 05/28/2023]
Abstract
Ultrasonic backscatter techniques are being developed to diagnose osteoporosis. Tissues that lie between the transducer and the ultrasonically interrogated region of bone may produce errors in backscatter measurements. The goal of this study is to investigate the effects of intervening tissues on ultrasonic backscatter measurements of bone. Measurements were performed on 24 cube shaped specimens of human cancellous bone using a 5 MHz transducer. Measurements were repeated after adding a 1 mm thick plate of cortical bone to simulate the bone cortex and a 3 cm thick phantom to simulate soft tissue at the hip. Signals were analyzed to determine three apparent backscatter parameters (apparent integrated backscatter, frequency slope of apparent backscatter, and frequency intercept of apparent backscatter) and three backscatter difference parameters [normalized mean backscatter difference (nMBD), normalized slope of the backscatter difference, and normalized intercept of the backscatter difference]. The apparent backscatter parameters were impacted significantly by the presence of intervening tissues. In contrast, the backscatter difference parameters were not affected by intervening tissues. However, only one backscatter difference parameter, nMBD, demonstrated a strong correlation with bone mineral density. Thus, among the six parameters tested, nMBD may be the best choice for in vivo backscatter measurements of bone when intervening tissues are present.
Collapse
Affiliation(s)
| | - P Luke Spinolo
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Mark E Sellers
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Peyton L Marshall
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Ann M Viano
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Sang-Rok Lee
- Department of Kinesiology and Dance, New Mexico State University, Las Cruces, New Mexico 88003, USA
| |
Collapse
|
32
|
Liu C, Tang T, Xu F, Ta D, Matsukawa M, Hu B, Wang W. Signal of Interest Selection Standard for Ultrasonic Backscatter in Cancellous Bone Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2015. [PMID: 26210784 DOI: 10.1016/j.ultrasmedbio.2015.06.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The aim of this study was to examine the effect of the backscattered signal of interest (SOI) on ultrasonic cancellous bone evaluation. In vitro backscatter measurements were performed using 16 bovine cancellous bone specimens and six different transducers with central frequencies of 0.5, 1, 2.25, 3.5, 5 and 10 MHz. The SOI for signal analysis was selected by a rectangular window. The delay (T1) and duration (T2) of the time window were varied, and the apparent integrated backscatter (AIB) and its correlation to bone volume fraction (BV/TV) were calculated. The results indicate that in addition to affecting the measured value of AIB, the SOI influences the observed correlation between AIB and BV/TV. Strong positive correlations were observed for short T1 (0.5 MHz: ≤6 μs, 1 MHz: ≤3 μs, 2.25 and 3.5 MHz: ≤2 μs, 5 and 10 MHz: ≤1 μs). However, strong negative correlations were observed when T1 was long (0.5 MHz: >9 μs, 1 MHz: >7 μs, 2.25 and 3.5 MHz: >3 μs, 5 and 10 MHz: >2 μs). The T2 value, especially low values (≤3 μs), also influenced the correlation coefficients. Positive correlations were more commonly observed at lower frequencies (i.e., 0.5-1 MHz), whereas negative correlations were more common at higher frequencies (i.e., 2.25-10 MHz). An explicit standard for in vitro SOI selection and cancellous bone assessment was proposed for a broad frequency range (0.5-10 MHz). Current conflicting findings are explained, and constructive suggestions for ultrasonic backscatter cancellous bone evaluation are provided.
Collapse
Affiliation(s)
- Chengcheng Liu
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Tao Tang
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Feng Xu
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai, China.
| | - Mami Matsukawa
- Lab of Ultrasonic Electronics, Doshisha University, Kyoto, Japan
| | - Bo Hu
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Weiqi Wang
- Department of Electronic Engineering, Fudan University, Shanghai, China
| |
Collapse
|
33
|
Pfister R, Michels G, Sharp SJ, Luben R, Wareham NJ, Khaw KT. Inverse association between bone mineral density and risk of aortic stenosis in men and women in EPIC–Norfolk prospective study. Int J Cardiol 2015; 178:29-30. [DOI: 10.1016/j.ijcard.2014.10.065] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2014] [Accepted: 10/20/2014] [Indexed: 12/22/2022]
|
34
|
Conversano F, Franchini R, Greco A, Soloperto G, Chiriacò F, Casciaro E, Aventaggiato M, Renna MD, Pisani P, Di Paola M, Grimaldi A, Quarta L, Quarta E, Muratore M, Laugier P, Casciaro S. A novel ultrasound methodology for estimating spine mineral density. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:281-300. [PMID: 25438845 DOI: 10.1016/j.ultrasmedbio.2014.08.017] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 08/14/2014] [Accepted: 08/20/2014] [Indexed: 05/10/2023]
Abstract
We investigated the possible clinical feasibility and accuracy of an innovative ultrasound (US) method for diagnosis of osteoporosis of the spine. A total of 342 female patients (aged 51-60 y) underwent spinal dual X-ray absorptiometry and abdominal echographic scanning of the lumbar spine. Recruited patients were subdivided into a reference database used for US spectral model construction and a study population for repeatability and accuracy evaluation. US images and radiofrequency signals were analyzed via a new fully automatic algorithm that performed a series of spectral and statistical analyses, providing a novel diagnostic parameter called the osteoporosis score (O.S.). If dual X-ray absorptiometry is assumed to be the gold standard reference, the accuracy of O.S.-based diagnoses was 91.1%, with k = 0.859 (p < 0.0001). Significant correlations were also found between O.S.-estimated bone mineral densities and corresponding dual X-ray absorptiometry values, with r(2) values up to 0.73 and a root mean square error of 6.3%-9.3%. The results obtained suggest that the proposed method has the potential for future routine application in US-based diagnosis of osteoporosis.
Collapse
Affiliation(s)
| | - Roberto Franchini
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | | | - Giulia Soloperto
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - Fernanda Chiriacò
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - Ernesto Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | | | | | - Paola Pisani
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - Marco Di Paola
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - Antonella Grimaldi
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy
| | - Laura Quarta
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy
| | - Eugenio Quarta
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy
| | - Maurizio Muratore
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy
| | - Pascal Laugier
- Laboratoire d'Imagerie Biomédicale, Sorbonne Universités, UPMC 06, INSERM, CNRS, Paris, France
| | - Sergio Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce, Italy.
| |
Collapse
|
35
|
Lee KI. Correlations of linear and nonlinear ultrasound parameters with density and microarchitectural parameters in trabecular bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 134:EL381-EL386. [PMID: 24181979 DOI: 10.1121/1.4822420] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In the present study, correlations of linear and nonlinear ultrasound parameters (speed of sound, normalized broadband ultrasound attenuation, and nonlinear parameter B/A) with bone mineral density and microarchitectural parameters were investigated in 28 bovine femoral trabecular bone samples in vitro. All three ultrasound parameters exhibited relatively high correlation coefficients with the indexes of bone quantity (bone mineral density and bone volume fraction) and lower correlation coefficients with the remaining microarchitectural parameters. These results suggest that B/A, in addition to speed of sound and attenuation, may have potential as an index for the assessment of bone status and osteoporosis.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea
| |
Collapse
|
36
|
Chin KY, Ima-Nirwana S. Calcaneal quantitative ultrasound as a determinant of bone health status: what properties of bone does it reflect? Int J Med Sci 2013; 10:1778-83. [PMID: 24273451 PMCID: PMC3837236 DOI: 10.7150/ijms.6765] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2013] [Accepted: 08/14/2013] [Indexed: 11/16/2022] Open
Abstract
Quantitative ultrasound (QUS) has emerged as a convenient and popular screening tool for osteoporosis. This review aimed to provide basic information on the principle of QUS measurement and discuss the properties of bone reflected by QUS indices. QUS employed high frequency sound waves generated by the device to determine bone health status in humans. In vitro studies showed that QUS indices were significantly associated with bone mineral density (BMD), bone microarchitecture and mechanical parameters. In humans, QUS indices were found to be associated with BMD as well. In addition, QUS could discriminate subjects with and without fracture history and predict risk for future fracture. In conclusion, QUS is able to reflect bone quality and should be used in the screening of osteoporosis, especially in developing countries where dual-X-ray absorptiometry devices are less accessible to the general population.
Collapse
Affiliation(s)
- Kok-Yong Chin
- Department of Pharmacology, Faculty of Medicine, Universiti Kebangsaan Malaysia
| | | |
Collapse
|
37
|
Hwang KS, Lee KI. Influence of cortical endplate on speed of sound in bovine femoral trabecular bone in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:EL463-EL469. [PMID: 23231209 DOI: 10.1121/1.4767449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Speed of sound (SOS) was measured in 14 bovine femoral trabecular bone samples with and without the cortical endplates with various thicknesses of 1.00, 1.31, 1.47, 1.75, and 2.00 mm. The presence of the cortical endplates resulted in an increase in the mean SOS of 16 m/s (+0.9%) to 91 m/s (+5.3%). The mean SOS measured in the samples with and without the cortical endplates exhibited similar significant correlations with apparent bone density (r = 0.86-0.91). All the SOS measurements were also found to be highly correlated with each other (r = 0.89-0.99).
Collapse
Affiliation(s)
- Kyo Seung Hwang
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea.
| | | |
Collapse
|
38
|
Lee KI. Ultrasonic properties in marrow-filled and water-filled bovine femoral trabecular bones in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:EL296-EL302. [PMID: 23039568 DOI: 10.1121/1.4751989] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Phase velocity and normalized broadband ultrasound attenuation (nBUA) were measured in 22 marrow-filled and water-filled bovine femoral trabecular bone samples. Replacement of marrow by water led to a significant increase in the mean phase velocity of 47 ± 12 m/s (+3.1%), but a decrease in the mean nBUA of 10.4 ± 2.9 dB/cm/MHz (-38.9%). All the ultrasonic properties in the marrow-filled and water-filled samples exhibited significant negative Pearson's correlation coefficients of r = -0.87 to -0.92 with porosity. High correlations were also observed between pairs of the ultrasonic properties, with r = 0.85 to 0.93.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea.
| |
Collapse
|