1
|
Li Q, Chen Q, Xiao S, Wang S, Ge X, Wang Q, Zheng L, Wei Q, Du W, Shen W, Wu Y, Song J. A Salidroside-Based Radiosensitizer Regulates the Nrf2/ROS Pathway for X-Ray Activated Synergistic Cancer Precise Therapy. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2025:e2413226. [PMID: 40195850 DOI: 10.1002/adma.202413226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 03/26/2025] [Indexed: 04/09/2025]
Abstract
The hypoxic microenvironment and radioresistance of tumor cells, as well as the delay in efficacy evaluation, significantly limit the effect of clinical radiotherapy. Therefore, developing effective radiosensitizers with monitoring of tumor response is of great significance for precise radiotherapy. Herein, a novel radiosensitizer (term as: SCuFs) is developed, consisting of traditional Chinese medicine (TCM) compounds salidroside, Cu2+, and hydroxyl radical (•OH) activated second near-infrared window fluorescence (NIR-II FL) molecules, which make the radiosensitization effect and boosted chemodynamic therapy (CDT) efficacy. The overexpressed glutathione in the tumor induces the SCuFs dissociation, allowing deep penetration of the drug to the whole tumor region. After X-ray irradiation, salidroside inhibits the Nuclear factor erythroid 2-like 2 (Nrf2)protein expression and blocks cells in the G2/M phase with the highest radiosensitivity, which amplifies the reactive oxygen species (ROS) generation to exacerbate DNA damage, thus achieving radiosensitization. Meanwhile, the upregulated ROS provides sufficient chemical fuel for Cu+-mediated CDT to produce more •OH. NIR-II FL imaging can monitor the •OH changes during the therapy process, confirming the radiosensitization effect and CDT process related to •OH. This study not only achieves effective radiosensitization and cascaded ROS-mediated CDT efficacy, but also provides a useful tool for monitoring therapeutic efficacy, showing great prospects for clinical application.
Collapse
Affiliation(s)
- Qingqing Li
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, College of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Qing Chen
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Shenggan Xiao
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, College of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Shuhan Wang
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, College of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Xiaoguang Ge
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, College of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Qian Wang
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Liting Zheng
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, College of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Qiaoqiao Wei
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Wei Du
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, College of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Wenbin Shen
- Department of Radiotherapy, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, China
| | - Ying Wu
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Jibin Song
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029, China
| |
Collapse
|
2
|
Zhang C, Yang Y, Qin D, Hu R, Hu L. Silver nanocluster-based ratiometric fluorescence sensors for X-ray dose detection. Talanta 2024; 271:125631. [PMID: 38241924 DOI: 10.1016/j.talanta.2024.125631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/28/2023] [Accepted: 01/04/2024] [Indexed: 01/21/2024]
Abstract
In this paper, we synthesized silver nanoclusters using bovine serum albumin (BSA) as a template (BSA@AgNCs). Then, we anchored hydroxyphenyl fluorescein (HPF) to yield HPF-BSA@AgNCs. When exposed to X-rays, hydroxyl (∙OH) radicals generated by radiolysis of water react with HPF to produce fluorescein, which emits enhanced fluorescence at 515 nm (λex = 480 nm). The fluorescence intensity of BSA@AgNCs at 685 nm (λex = 480 nm) remains stable when exposed to X-rays. This HPF-BSA@AgNCs ratiometric fluorescence sensor can rapidly detect 0.1-20 Gy (the energy deposited per unit mass, J/kg) of X-rays. In addition, HPF-BSA@AgNCs exhibit good durability and temperature stability. Finally, HPF-BSA@AgNCs were used to measure the absorbed doses of A549 cells and evaluate the cell irradiation damage.
Collapse
Affiliation(s)
- Chengfang Zhang
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China
| | - Yuanyuan Yang
- Department of Oncology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou, China
| | - Danni Qin
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China
| | - Rui Hu
- Department of Radiation Oncology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, China.
| | - Liang Hu
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China.
| |
Collapse
|
3
|
Lu H, Zheng Z, Hou H, Bai Y, Qiu J, Wang J, Lin J. Fine-Tuning X-Ray Sensitivity in Organic-Inorganic Hybrids via an Unprecedented Mixed-Ligand Strategy. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2305378. [PMID: 37939314 PMCID: PMC10767407 DOI: 10.1002/advs.202305378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/21/2023] [Indexed: 11/10/2023]
Abstract
Crystalline organic-inorganic hybrids, which exhibit colorimetric responses to ionizing radiation, have recently been recognized as promising alternatives to conventional X-ray dosimeters. However, X-ray-responsive organic-inorganic hybrids are scarce and the strategy to fine-tune their detection sensitivity remains elusive. Herein, an unprecedented mixed-ligand strategy is reported to modulate the X-ray detection efficacy of organic-inorganic hybrids. Deliberately blending the stimuli-responsive terpyridine carboxylate ligand (tpc- ) and the auxiliary pba- group with different ratios gives rise to two OD thorium-bearing clusters (Th-102 and Th-103) and a 1D coordination polymer (Th-104). Notably, distinct X-ray sensitivity is evident as a function of molar ratio of the tpc- ligand, following the trend of Th-102 > Th-103 > Th-104. Moreover, Th-102, which is exclusively built from the tpc- ligands with the highest degree of π-π interactions, exhibits the most sensitive radiochromic and fluorochromic responses toward X-ray with the lowest detection limit of 1.5 mGy. The study anticipates that this mixed-ligand strategy will be a versatile approach to tune the X-ray sensing efficacy of organic-inorganic hybrids.
Collapse
Affiliation(s)
- Huangjie Lu
- Shanghai Institute of Applied PhysicsChinese Academy of Sciences2019 Jia Luo RoadShanghai201800P. R. China
| | - Zhaofa Zheng
- Shanghai Institute of Applied PhysicsChinese Academy of Sciences2019 Jia Luo RoadShanghai201800P. R. China
| | - Huiliang Hou
- Shanghai Institute of Applied PhysicsChinese Academy of Sciences2019 Jia Luo RoadShanghai201800P. R. China
| | - Yaoyao Bai
- School of Nuclear Science and TechnologyXi'an Jiaotong UniversityNo.28, West Xianning RoadXi'an710049P. R. China
| | - Jie Qiu
- School of Nuclear Science and TechnologyXi'an Jiaotong UniversityNo.28, West Xianning RoadXi'an710049P. R. China
| | - Jian‐Qiang Wang
- Shanghai Institute of Applied PhysicsChinese Academy of Sciences2019 Jia Luo RoadShanghai201800P. R. China
| | - Jian Lin
- School of Nuclear Science and TechnologyXi'an Jiaotong UniversityNo.28, West Xianning RoadXi'an710049P. R. China
| |
Collapse
|
4
|
Zhang T, He R, Ding X, Zhao M, Wang C, Zhu S, Liao Y, Wang D, Wang H, Guo J, Liu Y, Zhou Z, Gu Z, Hu H. Fullerenols Mitigate Radiation-Induced Myocardial Injury. Adv Healthc Mater 2023; 12:e2300819. [PMID: 37698231 DOI: 10.1002/adhm.202300819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 07/19/2023] [Indexed: 09/13/2023]
Abstract
Radiation-induced heart disease is a serious side effect of radiation therapy that can lead to severe consequences. However, effective and safe methods for their prevention and treatment are presently lacking. This study reports the crucial function of fullerenols in protecting cardiomyocytes from radiation injury. First, fullerenols are synthesized using a simple base-catalyzed method. Next, the as-prepared fullerenols are applied as an effective free radical scavenger and broad-spectrum antioxidant to protect against X-ray-induced cardiomyocyte injury. Their ability to reduce apoptosis via the mitochondrial signaling pathway at the cellular level is then verified. Finally, it is observed in animal models that fullerenols accumulate in the heart and alleviate myocardial damage induced by X-rays. This study represents a timely and essential analysis of the prevention and treatment of radiological myocardial injury, providing new insights into the applications of fullerenols for therapeutic strategies.
Collapse
Affiliation(s)
- Tingjun Zhang
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
- Department of Infectious Diseases, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, P. R. China
| | - Rendong He
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
- Department of Clinical Laboratory, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, P. R. China
| | - Xuefeng Ding
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
- Department of Critical Care Medicine, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, P. R. China
| | - Maoru Zhao
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
- Center of Materials Science and Optoelectronics Engineering, College of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Chengyan Wang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Shuang Zhu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
- Center of Materials Science and Optoelectronics Engineering, College of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - You Liao
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
- Center of Materials Science and Optoelectronics Engineering, College of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Dongmei Wang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
- Center of Materials Science and Optoelectronics Engineering, College of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Hao Wang
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
| | - Junsong Guo
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
| | - Yaping Liu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Zhonghui Zhou
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
| | - Zhanjun Gu
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
- Center of Materials Science and Optoelectronics Engineering, College of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Houxiang Hu
- Academician Workstation, Affiliated Hospital of North Sichuan Medical College Nanchong, Nanchong, 637000, P. R. China
| |
Collapse
|
5
|
Aboelezz E, Pogue BW. Review of nanomaterial advances for ionizing radiation dosimetry. APPLIED PHYSICS REVIEWS 2023; 10:021312. [PMID: 37304732 PMCID: PMC10249220 DOI: 10.1063/5.0134982] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 05/01/2023] [Indexed: 06/13/2023]
Abstract
There are a wide range of applications with ionizing radiation and a common theme throughout these is that accurate dosimetry is usually required, although many newer demands are provided by improved features in higher range, multi-spectral and particle type detected. Today, the array of dosimeters includes both offline and online tools, such as gel dosimeters, thermoluminescence (TL), scintillators, optically stimulated luminescence (OSL), radiochromic polymeric films, gels, ionization chambers, colorimetry, and electron spin resonance (ESR) measurement systems. Several future nanocomposite features and interpretation of their substantial behaviors are discussed that can lead to improvements in specific features, such as (1) lower sensitivity range, (2) less saturation at high range, (3) overall increased dynamic range, (4) superior linearity, (5) linear energy transfer and energy independence, (6) lower cost, (7) higher ease of use, and (8) improved tissue equivalence. Nanophase versions of TL and ESR dosimeters and scintillators each have potential for higher range of linearity, sometimes due to superior charge transfer to the trapping center. Both OSL and ESR detection of nanomaterials can have increased dose sensitivity because of their higher readout sensitivity with nanoscale sensing. New nanocrystalline scintillators, such as perovskite, have fundamentally important advantages in sensitivity and purposeful design for key new applications. Nanoparticle plasmon coupled sensors doped within a lower Zeff material have been an effective way to achieve enhanced sensitivity of many dosimetry systems while still achieving tissue equivalency. These nanomaterial processing techniques and unique combinations of them are key steps that lead to the advanced features. Each must be realized through industrial production and quality control with packaging into dosimetry systems that maximize stability and reproducibility. Ultimately, recommendations for future work in this field of radiation dosimetry were summarized throughout the review.
Collapse
Affiliation(s)
- Eslam Aboelezz
- Ionizing Radiation Metrology Department, National Institute of Standards, Giza, Egypt
| | - Brian W. Pogue
- Department of Medical Physics, University of Wisconsin-Madison, Madison 53705, USA
| |
Collapse
|
6
|
Dong X, Tian Y, Wang F, Chen C, Wang Y, Ma J. Gold-Nanoparticle-Enhanced Radio-Fluorogenic Hydrogel Sensor for Low Radiation Doses in Clinical Radiotherapy. Polymers (Basel) 2022; 14:4841. [PMID: 36432968 PMCID: PMC9694710 DOI: 10.3390/polym14224841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 11/08/2022] [Indexed: 11/12/2022] Open
Abstract
Radio-fluorogenic hydrogel dosimeters are urgently needed in radiotherapy for 3D dose verification. However, few hydrogel sensors have been reported at low absorbed doses under 2 Gy which meets the requirements of clinical practice. Here, we report a new type of gold-nanoparticle-enhanced radio-fluorogenic agarose hydrogel with coumarin as the dose-responsive material. An optimal composition of 3 wt% of agarose, 0.1 mM of gold nanoparticles, and 0.5 mM coumarin was selected. The addition of gold nanoparticles enhanced the hydroxyl radicals generated from the radiolysis of water, which can react with coumarin and generate fluorescent 7-hydroxy-coumarin and, eventually, achieve low-dose verification of 0-2.4 Gy with a high linear correlation coefficient. These findings provide an effective method for 3D dose verification, and will inspire the development of other radio-fluorogenic sensing hydrogels as well.
Collapse
Affiliation(s)
| | | | | | | | - Yunlong Wang
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Jun Ma
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| |
Collapse
|
7
|
Shin DS, Kim TH, Rah JE, Kim D, Yang HJ, Lee SB, Lim YK, Jeong J, Kim H, Shin D, Son J. Assessment of a Therapeutic X-ray Radiation Dose Measurement System Based on a Flexible Copper Indium Gallium Selenide Solar Cell. SENSORS (BASEL, SWITZERLAND) 2022; 22:5819. [PMID: 35957376 PMCID: PMC9370937 DOI: 10.3390/s22155819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 08/02/2022] [Accepted: 08/02/2022] [Indexed: 06/15/2023]
Abstract
Several detectors have been developed to measure radiation doses during radiotherapy. However, most detectors are not flexible. Consequently, the airgaps between the patient surface and detector could reduce the measurement accuracy. Thus, this study proposes a dose measurement system based on a flexible copper indium gallium selenide (CIGS) solar cell. Our system comprises a customized CIGS solar cell (with a size 10 × 10 cm2 and thickness 0.33 mm), voltage amplifier, data acquisition module, and laptop with in-house software. In the study, the dosimetric characteristics, such as dose linearity, dose rate independence, energy independence, and field size output, of the dose measurement system in therapeutic X-ray radiation were quantified. For dose linearity, the slope of the linear fitted curve and the R-square value were 1.00 and 0.9999, respectively. The differences in the measured signals according to changes in the dose rates and photon energies were <2% and <3%, respectively. The field size output measured using our system exhibited a substantial increase as the field size increased, contrary to that measured using the ion chamber/film. Our findings demonstrate that our system has good dosimetric characteristics as a flexible in vivo dosimeter. Furthermore, the size and shape of the solar cell can be easily customized, which is an advantage over other flexible dosimeters based on an a-Si solar cell.
Collapse
Affiliation(s)
- Dong-Seok Shin
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Tae-Ho Kim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Jeong-Eun Rah
- Department of Radiation Oncology, Myongji Hospital, Goyang 10475, Korea
| | - Dohyeon Kim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Hye Jeong Yang
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Se Byeong Lee
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Young Kyung Lim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Jonghwi Jeong
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Haksoo Kim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Dongho Shin
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Jaeman Son
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Korea
| |
Collapse
|
8
|
Zhang P, Jiang L, Chen H, Hu L. Recent Advances in Hydrogel-Based Sensors Responding to Ionizing Radiation. Gels 2022; 8:gels8040238. [PMID: 35448139 PMCID: PMC9024575 DOI: 10.3390/gels8040238] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 04/03/2022] [Accepted: 04/10/2022] [Indexed: 12/20/2022] Open
Abstract
Ionizing radiation and its applications are widely spread throughout life. Similar to many other things, both the positive and negative aspects of ionizing radiation should always be kept in mind. For example, a proper radiation dose can be delivered to tumor tissue to kill malignant cells in radiotherapy. On the other hand, exceeding this dose can damage the normal tissues of a human organism. Therefore, the application of sensors for measuring ionizing radiation doses is of utmost importance in many fields, especially in cancer therapy. Traditional dosimeters, such as ionization chambers, silicon diodes and thermoluminescence dosimeters, are widely used. However, they have limitations in certain aspects. Hydrogel-based sensors (or dosimeters) for measuring ionizing radiation doses attract extensive attention for decades due to their equivalence to living tissue and biocompatibility. In this review, we catalog hydrogel-based dosimeters such as polymer, Fricke, radio-chromic, radio-fluorescence and NPs-embedded dosimeters. Most of them demonstrate desirable linear response and sensitivity regardless of energy and dose rate of ionizing radiation. We aim to review these dosimeters and their potential applications in radiotherapy as well as to stimulate a joint work of the experts from different fields such as materials science, chemistry, cancer therapy, radiobiology and nuclear science.
Collapse
Affiliation(s)
- Ping Zhang
- State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China; (P.Z.); (H.C.)
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, China;
| | - Li Jiang
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, China;
| | - Hong Chen
- State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China; (P.Z.); (H.C.)
| | - Liang Hu
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, China;
- Correspondence:
| |
Collapse
|
9
|
Pushpavanam K, Dutta S, Inamdar S, Bista T, Sokolowski T, Rapchak A, Sadeghi A, Sapareto S, Rege K. Versatile Detection and Monitoring of Ionizing Radiation Treatment Using Radiation-Responsive Gel Nanosensors. ACS APPLIED MATERIALS & INTERFACES 2022; 14:14997-15007. [PMID: 35316013 DOI: 10.1021/acsami.2c01019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Modern radiation therapy workflow involves complex processes intended to maximize the radiation dose delivered to tumors while simultaneously minimizing excess radiation to normal tissues. Safe and accurate delivery of radiation doses is critical to the successful execution of these treatment plans and effective treatment outcomes. Given extensive differences in existing dosimeters, the choice of devices and technologies for detecting biologically relevant doses of radiation has to be made judiciously, taking into account anatomical considerations and modality of treatment (invasive, e.g., interstitial brachytherapy vs noninvasive, e.g., external-beam therapy radiotherapy). Rapid advances in versatile radiation delivery technologies necessitate new detection platforms and devices that are readily adaptable into a multitude of form factors in order to ensure precision and safety in dose delivery. Here, we demonstrate the adaptability of radiation-responsive gel nanosensors as a platform technology for detecting ionizing radiation using three different form factors with an eye toward versatile use in the clinic. In this approach, ionizing radiation results in the reduction of monovalent gold salts leading to the formation of gold nanoparticles within gels formulated in different morphologies including one-dimensional (1D) needles for interstitial brachytherapy, two-dimensional (2D) area inserts for skin brachytherapy, and three-dimensional (3D) volumetric dose distribution in tissue phantoms. The formation of gold nanoparticles can be detected using distinct but complementary modes of readout including optical (visual) and photothermal detection, which further enhances the versatility of this approach. A linear response in the readout was seen as a function of radiation dose, which enabled straightforward calibration of each of these devices for predicting unknown doses of therapeutic relevance. Taken together, these results indicate that the gel nanosensor technology can be used to detect ionizing radiation in different morphologies and using different detection methods for application in treatment planning, delivery, and verification in radiotherapy and in trauma care.
Collapse
Affiliation(s)
- Karthik Pushpavanam
- Chemical Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Subhadeep Dutta
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
| | - Sahil Inamdar
- Chemical Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Tomasz Bista
- Banner-MD Anderson Cancer Center, Gilbert, Arizona 85234, United States
| | | | - Alek Rapchak
- Banner-MD Anderson Cancer Center, Gilbert, Arizona 85234, United States
| | - Amir Sadeghi
- Banner-MD Anderson Cancer Center, Gilbert, Arizona 85234, United States
| | - Stephen Sapareto
- Banner-MD Anderson Cancer Center, Gilbert, Arizona 85234, United States
| | - Kaushal Rege
- Chemical Engineering, Arizona State University, Tempe, Arizona 85287, United States
- Biological Design Graduate Program, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
10
|
Lu H, Hou H, Hou YC, Zheng Z, Ma Y, Zhou Z, Guo X, Pan QJ, Wang Y, Qian Y, Wang JQ, Lin J. A New Concept of Radiation Detection Based on a Fluorochromic and Piezochromic Nanocluster. J Am Chem Soc 2022; 144:3449-3457. [DOI: 10.1021/jacs.1c11496] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Huangjie Lu
- Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2019 Jia Luo Road, Shanghai 201800, China
- University of Chinese Academy of Sciences, No.19 (A) Yuquan Road, Shijingshan District, Beijing 100049, PR China
| | - Huiliang Hou
- Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2019 Jia Luo Road, Shanghai 201800, China
- University of Chinese Academy of Sciences, No.19 (A) Yuquan Road, Shijingshan District, Beijing 100049, PR China
| | - Yu-Chang Hou
- Key Laboratory of Functional Inorganic Material Chemistry (Ministry of Education), School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080, PR China
| | - Zhaofa Zheng
- Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2019 Jia Luo Road, Shanghai 201800, China
- University of Chinese Academy of Sciences, No.19 (A) Yuquan Road, Shijingshan District, Beijing 100049, PR China
| | - Yingying Ma
- Center for High Pressure Science and Technology Advanced Research (HPSTAR) Beijing 100094, PR China
| | - Zhengyang Zhou
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, PR China
| | - Xiaofeng Guo
- Department of Chemistry and Alexandra Navrotsky Institute for Experimental Thermodynamics, Washington State University Pullman, Washington 99164-4630, United States
| | - Qing-Jiang Pan
- Key Laboratory of Functional Inorganic Material Chemistry (Ministry of Education), School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080, PR China
| | - Yonggang Wang
- Center for High Pressure Science and Technology Advanced Research (HPSTAR) Beijing 100094, PR China
| | - Yuan Qian
- Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2019 Jia Luo Road, Shanghai 201800, China
- University of Chinese Academy of Sciences, No.19 (A) Yuquan Road, Shijingshan District, Beijing 100049, PR China
| | - Jian-Qiang Wang
- Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2019 Jia Luo Road, Shanghai 201800, China
- University of Chinese Academy of Sciences, No.19 (A) Yuquan Road, Shijingshan District, Beijing 100049, PR China
| | - Jian Lin
- School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, PR China
| |
Collapse
|
11
|
Pushpavanam K, Dutta S, Zhang N, Ratcliff T, Bista T, Sokolowski T, Boshoven E, Sapareto S, Breneman CM, Rege K. Radiation-Responsive Amino Acid Nanosensor Gel (RANG) for Radiotherapy Monitoring and Trauma Care. Bioconjug Chem 2021; 32:1984-1998. [PMID: 34384218 DOI: 10.1021/acs.bioconjchem.1c00262] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Accurate detection of doses is critical for the development of effective countermeasures and patient stratification strategies in cases of accidental exposure to ionizing radiation. Existing detection devices are limited by high fabrication costs, long processing times, need for sophisticated detection systems, and/or loss of readout signal over time, particularly in complex environments. Here, we describe fundamental studies on amino acid-facilitated templating of gold nanoparticles following exposure to ionizing radiation as a new colorimetric approach for radiation detection. Tryptophan demonstrated spontaneous nanoparticle formation, and parallel screening of a library of amino acids and related compounds led to the identification of lead candidates, including phenylalanine, which demonstrated an increase in absorbance at wavelengths typical of gold nanoparticles in the presence of ionizing radiation (X-rays). Evaluation of screening, i.e., absorbance data, in concert with chemical informatics modeling led to the elucidation of physicochemical properties, particularly polarizable regions and partial charges, that governed nanoparticle formation propensities upon exposure of amino acids to ionizing radiation. NMR spectroscopy revealed key roles of amino and carboxy moieties in determining the nanoparticle formation propensity of phenylalanine, a lead amino acid from the screen. These findings were employed for fabricating radiation-responsive amino acid nanosensor gels (RANGs) based on phenylalanine and tryptophan, and efficacy of RANGs was demonstrated for predicting clinical doses of ionizing radiation in anthropomorphic thorax phantoms and in live canine patients undergoing radiotherapy. The use of biocompatible templating ligands (amino acids), rapid response, simplicity of fabrication, efficacy, ease of operation and detection, and long-lasting readout indicate several advantages of the RANG over existing detection systems for monitoring radiation in clinical radiotherapy, radiological emergencies, and trauma care.
Collapse
Affiliation(s)
- Karthik Pushpavanam
- Chemical Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Subhadeep Dutta
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
| | - Ni Zhang
- Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Tyree Ratcliff
- Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Tomasz Bista
- Banner-MD Anderson Cancer Center, Gilbert, Arizona 85234, United States
| | | | - Eric Boshoven
- Arizona Veterinary Oncology, Gilbert, Arizona 85233, United States
| | - Stephen Sapareto
- Banner-MD Anderson Cancer Center, Gilbert, Arizona 85234, United States
| | - Curt M Breneman
- Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Kaushal Rege
- Chemical Engineering, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
12
|
Jiang L, Li W, Nie J, Wang R, Chen X, Fan W, Hu L. Fluorescent Nanogel Sensors for X-ray Dosimetry. ACS Sens 2021; 6:1643-1648. [PMID: 33761245 DOI: 10.1021/acssensors.1c00204] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
X-ray dosimeters are of significance for detecting the levels of ionizing radiation exposure in cells and phantoms; thus, they can further optimize X-ray radiotherapy in the clinic. In this paper, we designed a polyacrylamide-based nanogel sensor that is capable of measuring X-ray doses. The dosimeters were prepared by anchoring an X-ray-responsive probe (aminophenyl fluorescein, APF) to poly(acrylamide-co-N-(3-aminopropyl) methyl acrylamide) nanogels. The premise behind the dose measurement is the transition of APF to fluorescence in the presence of hydroxyl radicals that are caused by the radiolysis of water molecules under X-rays. Therefore, the dose of X-rays can be readily detected by measuring the fluorescence intensity of the resultant nanogel immediately after irradiation using fluorescence spectroscopy principles. Using an RS2000 X-ray biological irradiator, our dosimeters showed good linearity responsivity at X-ray doses ranging from 0 to 15 Gy, with a limit of detection (LOD) of 0.5 Gy. Additionally, the signals showed temperature stability (25-65 °C), durability (5 weeks), and dose-rate (1.177 and 6 Gy/min) and energy independence (160 kVp and 6 MV). As a proof-of-concept, we used our sensors to fluorescently detect X-ray doses in A549 tumor cells and 3D-printed eye phantoms. The results showed that our dosimeters were able to accurately predict doses similar to those used by treatment plan systems.
Collapse
Affiliation(s)
- Li Jiang
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215006, China
| | - Wenxiang Li
- The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang 310003, China
| | - Jing Nie
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215006, China
| | - Rensheng Wang
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215006, China
| | - Xinjian Chen
- School of Electronics and Information Engineering, Soochow University, Suzhou 215006, China
| | - Wenhui Fan
- Radiotherapy Division, Department of Oral and Maxillofacial-Head Neck Oncology, Shanghai Ninth People’s Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
- National Clinical Research Center for Oral Diseases, Shanghai 200025, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai 200025, China
| | - Liang Hu
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215006, China
| |
Collapse
|
13
|
Pushpavanam K, Inamdar S, Dutta S, Bista T, Sokolowski T, Sapareto S, Rege K. Plasmonic gel nanocomposites for detection of high energy electrons. J Mater Chem B 2020; 8:4930-4939. [PMID: 32281998 DOI: 10.1039/d0tb00241k] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Radiation therapy is a common treatment modality employed in the treatment of cancer. High energy photons are the primary source of radiation but when administered, they leave an exit dose resulting in radiation damage to the adjacent healthy tissues. To overcome this, high energy electrons are employed in cases of skin cancer to minimize radiation induced toxicity. Despite these advances, measurement of delivered radiation remains a challenge due to limitations with existing dosimeters including labor intensive fabrication, complex read-out techniques and post-irradiation instability. To overcome these limitations, we have developed a novel colorimetric plasmonic gel nanocomposite for the detection of therapeutic levels of radiation delivered in electron beam therapy. The plasmonic nanocomposite consists of an agarose gel matrix encapsulating precursor gold ions, which are reduced to gold nanoparticles as a result of exposure to high energy electrons. The formation of gold nanoparticles renders a change in color to the agarose matrix, resulting in the formation of plasmonic gel nanocomposites. The intensity of the color formed exhibits a linear relation with the delivered electron dose, which can be quantified using absorbance spectroscopy. The plasmonic gel nanocomposites were able to detect doses employed in fractionated electron therapy, including in an anthropomorphic phantom used for planning radiation treatments in the clinic. Furthermore, the use of glutathione as a quenching agent facilitated qualitative and quantitative spatial mapping of the delivered dose. Our results indicate that the ease of fabrication, simplicity of detection and quantification using absorbance spectroscopy, determination of spatial dose profiles, and relatively low cost make the plasmonic gel nanocomposite technology attractive for detecting electron doses in the clinic.
Collapse
Affiliation(s)
- Karthik Pushpavanam
- Chemical Engineering, Arizona State University, 501 E. Tyler Mall, ECG 303, Tempe, AZ 85287-6106 85287, USA.
| | - Sahil Inamdar
- Chemical Engineering, Arizona State University, 501 E. Tyler Mall, ECG 303, Tempe, AZ 85287-6106 85287, USA.
| | - Subhadeep Dutta
- School of Molecular Sciences, Arizona State University, Tempe, AZ 85287, USA
| | - Tomasz Bista
- Banner-MD Anderson Cancer Center, Gilbert, AZ 85234, USA
| | | | | | - Kaushal Rege
- Chemical Engineering, Arizona State University, 501 E. Tyler Mall, ECG 303, Tempe, AZ 85287-6106 85287, USA.
| |
Collapse
|