1
|
Ratanpara A, Kim M, Kim YJ, Hidrovo CH. Spectral Characteristics of Water-Soluble Rhodamine Derivatives for Laser-Induced Fluorescence. J Fluoresc 2024:10.1007/s10895-024-03819-1. [PMID: 38954086 DOI: 10.1007/s10895-024-03819-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 06/24/2024] [Indexed: 07/04/2024]
Abstract
We present a comprehensive fluorescence characterization of seven water-soluble rhodamine derivatives for applications in laser-induced fluorescence (LIF) techniques. Absorption and emission spectra for these dyes are presented over the visible spectrum of wavelengths (400 to 700 nm). Their fluorescence properties were also investigated as a function of temperature for LIF thermometry applications. Rhodamine 110 depicted the least fluorescence emission sensitivity to temperature at -0.11%/°C, while rhodamine B depicted the most with a -1.55%/°C. We found that the absorption spectra of these molecules are independent of temperature, supporting the notion that the temperature sensitivity of their emission only comes from changes in quantum yield with temperature. Conversely, these rhodamine fluorophores showed no change in emission intensities with pH variations and are, therefore, not suitable tracers for pH measurements. Similarly, fluorescent lifetime, which is also a property sensitive to local environmental changes in temperature, pH, and ion concentration, measurements were conducted for these fluorophores. It was found that rhodamine B and kiton red 620 have shorter fluorescence timescales compared to those of the other five rhodamine dyes, making them least suitable for applications where temporal changes in emission are monitored. Lastly, we conducted experiments to assess the physicochemical absorption characteristics of these dyes' molecules into polydimethylsiloxane (PDMS), the most common material for microfluidic devices. Rhodamine B showed the highest diffusion into PDMS substrates as compared to the other derivative dyes.
Collapse
Affiliation(s)
- Abhishek Ratanpara
- Ocean and Mechanical Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, FL, 33431, USA
| | - Myeongsub Kim
- Ocean and Mechanical Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, FL, 33431, USA.
| | - Yeo Jun Kim
- Multiscale Thermal Fluids Laboratory, Mechanical Engineering Department, The University of Texas at Austin, 204 E. Dean Keeton, Austin, TX, 78712, USA
| | - Carlos H Hidrovo
- Multiscale Thermal Fluids Laboratory, Mechanical and Industrial Engineering Department, Northeastern University, 360 Huntington Ave, Boston, MA, 02114, USA
| |
Collapse
|
2
|
Casto-Boggess LD, Golozar M, Butterworth AL, Mathies RA. Optimization of Fluorescence Labeling of Trace Analytes: Application to Amino Acid Biosignature Detection with Pacific Blue. Anal Chem 2021; 94:1240-1247. [PMID: 34965088 DOI: 10.1021/acs.analchem.1c04465] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Fluorescence labeling of biomolecules and fluorescence detection platforms provide a powerful approach to high-sensitivity bioanalysis. Reactive probes can be chosen to target specific functional groups to enable selective analysis of a chosen class of analytes. Particularly, when targeting trace levels of analytes, it is important to optimize the reaction chemistry to maximize the labeling efficiency and minimize the background. Here, we develop methods to optimize the labeling and detection of Pacific Blue (PB)-tagged amino acids. A model is developed to quantitate labeling kinetics and completeness in the circumstance where analyte labeling and reactive probe hydrolysis are in competition. The rates of PB hydrolysis and amino acid labeling are determined as a function of pH. Labeling kinetics and completeness as a function of PB concentration are found to depend on the ratio of the hydrolysis time to the initial labeling time, which depends on the initial PB concentration. Finally, the optimized labeling and detection conditions are used to perform capillary electrophoresis analysis demonstrating 100 pM sensitivities and high-efficiency separations of an 11 amino acid test set. This work provides a quantitative optimization model that is applicable to a variety of reactive probes and targets. Our approach is particularly useful for the analysis of trace amine and amino acid biosignatures in extraterrestrial samples. For illustration, our optimized conditions (reaction at 4 °C in a pH 8.5 buffer) are used to detect trace amino acid analytes at the 100 pM level in an Antarctic ice core sample.
Collapse
Affiliation(s)
- Laura D Casto-Boggess
- Space Sciences Laboratory, University of California Berkeley, Berkeley, California 94720-7450, United States
| | - Matin Golozar
- Chemistry Department and Space Sciences Laboratory, University of California Berkeley, Berkeley, California 94720, United States
| | - Anna L Butterworth
- Space Sciences Laboratory, University of California Berkeley, Berkeley, California 94720-7450, United States
| | - Richard A Mathies
- Chemistry Department and Space Sciences Laboratory, University of California Berkeley, Berkeley, California 94720, United States
| |
Collapse
|
3
|
Dong C, Wang Q, Xu Z, Deng L, Zhang T, Lu B, Wang Q, Ren J. The Theoretical Model, Method, and Applications of Scattering Photon Burst Counting Based on an Objective Scanning Technique. Anal Chem 2021; 93:12556-12564. [PMID: 34477357 DOI: 10.1021/acs.analchem.1c01834] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Scattering photon burst counting (SPBC) is a single-particle detection method, which is based on measuring scattering photon bursting of single nanoparticles through a detection volume of <1 fL. Although SPBC has been used for bioassays and analysis of nanoparticles, it is necessary to establish its theoretical model and develop a new detection mode in order to further enhance its sensitivity and enlarge its application fields. In this paper, we proposed a theoretical model for the confocal SPBC method and developed a novel SPBC detection mode using the fast objective scanning technique. The computer simulations and experiments documented that this model well describes the relation between photon counts and experimental parameters (such as nanoparticle concentration and diameter, temperature, and viscosity). Based on this model, we developed a novel SPBC detection mode by using the fast objective scanning technique. Compared to the current confocal SPBC method, the sensitivity of this new method was significantly increased due to the significantly increased photon counts per sampling time, the linear detection range is from 0.9 to 90 pM, and the limit of detection is reduced to 40 fM for 30 nm gold nanoparticles. Furthermore, this new method was successfully applied to determine the enzyme activity of caspase-3 and evaluate the inhibition effectiveness of some inhibitors.
Collapse
Affiliation(s)
- Chaoqing Dong
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Qing Wang
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Zhenli Xu
- School of Mathematical Sciences and MOE-LSC, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Liyun Deng
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Tian Zhang
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Binglin Lu
- Anhui University of Science and Technology Affiliated Fengxian Hospital, 6600 Nanfeng Road, Shanghai 201499, China
| | - Qin Wang
- Anhui University of Science and Technology Affiliated Fengxian Hospital, 6600 Nanfeng Road, Shanghai 201499, China
| | - Jicun Ren
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| |
Collapse
|
4
|
Quantitative evaluation of the feasibility of sampling the ice plumes at Enceladus for biomarkers of extraterrestrial life. Proc Natl Acad Sci U S A 2021; 118:2106197118. [PMID: 34493668 PMCID: PMC8449353 DOI: 10.1073/pnas.2106197118] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 08/02/2021] [Indexed: 11/30/2022] Open
Abstract
The search for organic biosignatures indicative of life elsewhere in our solar system is an exciting quest that, if successful, will have a profound impact on our biological uniqueness. Saturn’s icy moon Enceladus is a promising location for a second occurrence of life due to its salty subsurface ocean. Plumes that jet out through the ice surface vents provide an enticing opportunity to sample the underlying ocean for biomarkers. The experiments reported here provide accurate modeling of our ability to fly through these plumes to efficiently and nondestructively gather ice particles for biomolecular analysis. Our measured efficiencies demonstrate that Saturn and/or Enceladus orbital missions will gather sufficient ice to make meaningful measurement of biosignatures in the Enceladus plumes. Enceladus, an icy moon of Saturn, is a compelling destination for a probe seeking biosignatures of extraterrestrial life because its subsurface ocean exhibits significant organic chemistry that is directly accessible by sampling cryovolcanic plumes. State-of-the-art organic chemical analysis instruments can perform valuable science measurements at Enceladus provided they receive sufficient plume material in a fly-by or orbiter plume transit. To explore the feasibility of plume sampling, we performed light gas gun experiments impacting micrometer-sized ice particles containing a fluorescent dye biosignature simulant into a variety of soft metal capture surfaces at velocities from 800 m ⋅ s−1 up to 3 km ⋅ s−1. Quantitative fluorescence microscopy of the capture surfaces demonstrates organic capture efficiencies of up to 80 to 90% for isolated impact craters and of at least 17% on average on indium and aluminum capture surfaces at velocities up to 2.2 km ⋅ s−1. Our results reveal the relationships between impact velocity, particle size, capture surface, and capture efficiency for a variety of possible plume transit scenarios. Combined with sensitive microfluidic chemical analysis instruments, we predict that our capture system can be used to detect organic molecules in Enceladus plume ice at the 1 nM level—a sensitivity thought to be meaningful and informative for probing habitability and biosignatures.
Collapse
|
5
|
Lian H, He S, Chen C, Yan X. Flow Cytometric Analysis of Nanoscale Biological Particles and Organelles. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:389-409. [PMID: 30978294 DOI: 10.1146/annurev-anchem-061318-115042] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Analysis of nanoscale biological particles and organelles (BPOs) at the single-particle level is fundamental to the in-depth study of biosciences. Flow cytometry is a versatile technique that has been well-established for the analysis of eukaryotic cells, yet conventional flow cytometry can hardly meet the sensitivity requirement for nanoscale BPOs. Recent advances in high-sensitivity flow cytometry have made it possible to conduct precise, sensitive, and specific analyses of nanoscale BPOs, with exceptional benefits for bacteria, mitochondria, viruses, and extracellular vesicles (EVs). In this article, we discuss the significance, challenges, and efforts toward sensitivity enhancement, followed by the introduction of flow cytometric analysis of nanoscale BPOs. With the development of the nano-flow cytometer that can detect single viruses and EVs as small as 27 nm and 40 nm, respectively, more exciting applications in nanoscale BPO analysis can be envisioned.
Collapse
Affiliation(s)
| | | | - Chaoxiang Chen
- MOE Key Laboratory of Spectrochemical Analysis and Instrumentation; Key Laboratory for Chemical Biology of Fujian Province; Collaborative Innovation Center of Chemistry for Energy Material; and Department of Chemical Biology, College of Chemistry and Engineering, Xiamen University, Xiamen, Fujian 361005, China;
| | - Xiaomei Yan
- MOE Key Laboratory of Spectrochemical Analysis and Instrumentation; Key Laboratory for Chemical Biology of Fujian Province; Collaborative Innovation Center of Chemistry for Energy Material; and Department of Chemical Biology, College of Chemistry and Engineering, Xiamen University, Xiamen, Fujian 361005, China;
| |
Collapse
|
6
|
Amenson-Lamar EA, Sun L, Zhang Z, Bohn PW, Dovichi NJ. Detection of 1 zmol injection of angiotensin using capillary zone electrophoresis coupled to a Q-Exactive HF mass spectrometer with an electrokinetically pumped sheath-flow electrospray interface. Talanta 2019; 204:70-73. [PMID: 31357355 DOI: 10.1016/j.talanta.2019.05.079] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 05/13/2019] [Accepted: 05/17/2019] [Indexed: 12/15/2022]
Abstract
An electrokinetically pumped sheath-flow nanoelectrospray interface provides an efficient means of transferring ions from a capillary electrophoresis system into a mass spectrometer. To characterize its performance, we analyzed angiotensin solutions prepared in a background of 0.25 mg/mL of a BSA tryptic digest. Calibration curves were prepared from 10 zmol (10-21 mol) to 10 fmol (10-14 mol) of angiotensin injected into the capillary. A parallel reaction monitoring approach was used; MS1 was set to m/z = 523.8 ± 2, and fragment ion signals at 263.1389 (y2+) and 784.4095 (b6+) were used to generate selected ion electropherograms. Calibration curves based on peak areas were linear (log-log slope of 0.94 for the y2+ fragment and 0.98 for the b6+ fragment). We then injected 1-zmol (600 copies) of angiotensin in the BSA background using a 10-μm ID separation capillary. Triplicate analyses consistently produced co-migrating peaks for the two fragment ions. The b6+ electropherogram showed no background signal, whereas the y2+ electropherogram showed a few noise spikes that were smaller than the peak maximum. Bienayme-Tchebycheff inequality was used to estimate detection limits of 230 ymol (140 ions) injected into the separation capillary. To the best of our knowledge, these electropherograms present the smallest number of molecules detected using mass spectrometry coupled with a separation.
Collapse
Affiliation(s)
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, East Lansing, MI, 48824, USA
| | - Zhenbin Zhang
- Department of Chemistry, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Paul W Bohn
- Department of Chemistry, University of Notre Dame, Notre Dame, IN, 46556, USA; Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Norman J Dovichi
- Department of Chemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| |
Collapse
|
7
|
Optimization of dynamic pH barrage junction focusing for weakly alkaline or zwitterionic analytes in capillary electrophoresis. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1095:94-102. [DOI: 10.1016/j.jchromb.2018.07.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/16/2018] [Accepted: 07/20/2018] [Indexed: 01/17/2023]
|
8
|
Novotny MV. Development of capillary liquid chromatography: A personal perspective. J Chromatogr A 2017; 1523:3-16. [PMID: 28701267 PMCID: PMC5675780 DOI: 10.1016/j.chroma.2017.06.042] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 06/13/2017] [Accepted: 06/15/2017] [Indexed: 11/21/2022]
Abstract
This is a historical account on the development of capillary LC from its beginning to the present day. The first investigations into the viability of capillary LC date back to the late 1970s, a decade after the pioneering efforts in HPLC. The drastically reduced column dimensions were required to counter the slow solute diffusion in liquids. There were numerous instrumental difficulties with sample introduction and detection in the picoliter or even femtoliter volumes. High-efficiency separations were needed in the analysis of complex biological mixtures. Miniaturization brought distinct advantages in spectroscopic and electrochemical detection. Since the 1980s, column technologies underwent significant changes: (a) from glass-drawn microcapillaries to slurry-packed, small-diameter fused silica columns; and (b) in microcapillaries packed alternatively with sub-2-μm particles or monoliths. The viability of LC-MS combination has dramatically promoted the use of small-diameter capillaries. Through "omics technologies", capillary LC/tandem MS accounts for most applications in proteomics, glycomics and metabolomics.
Collapse
Affiliation(s)
- Milos V Novotny
- Department of Chemistry, Indiana University, 800 E. Kirkwood Ave., Bloomington, IN 47405, USA.
| |
Collapse
|
9
|
Galievsky VA, Stasheuski AS, Krylov SN. "Getting the best sensitivity from on-capillary fluorescence detection in capillary electrophoresis" - A tutorial. Anal Chim Acta 2016; 935:58-81. [PMID: 27543015 DOI: 10.1016/j.aca.2016.06.015] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2016] [Revised: 06/09/2016] [Accepted: 06/11/2016] [Indexed: 01/09/2023]
Abstract
Capillary electrophoresis with Laser-Induced Fluorescence (CE-LIF) detection is being applied to new analytical problems which challenge both the power of CE separation and the sensitivity of LIF detection. On-capillary LIF detection is much more practical than post-capillary detection in a sheath-flow cell. Therefore, commercial CE instruments utilize solely on-capillary CE-LIF detection with a Limit of Detection (LOD) in the nM range, while there are multiple applications of CE-LIF that require pM or lower LODs. This tutorial analyzes all aspects of on-capillary LIF detection in CE in an attempt to identify means for improving LOD of CE-LIF with on-capillary detection. We consider principles of signal enhancement and noise reduction, as well as relevant areas of fluorophore photochemistry and fluorescent microscopy.
Collapse
Affiliation(s)
- Victor A Galievsky
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Alexander S Stasheuski
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Sergey N Krylov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada.
| |
Collapse
|
10
|
Nolan JP. Flow Cytometry of Extracellular Vesicles: Potential, Pitfalls, and Prospects. ACTA ACUST UNITED AC 2015; 73:13.14.1-13.14.16. [PMID: 26132176 DOI: 10.1002/0471142956.cy1314s73] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Evidence suggests that extracellular vesicles (EVs) can play roles in physiology and pathology, providing impetus to explore their use as diagnostic and therapeutic targets. However, EVs are also small, heterogeneous, and difficult to measure, and so this potential has not yet been realized. The development of improved approaches to EV detection and characterization will be critical to further understanding their roles in physiology and disease. Flow cytometry has been a popular tool for measuring cell-derived EVs, but has often been used in an uncritical manner in which fundamental principles and limitations of the instrument are ignored. Recent efforts to standardize procedures and document the effects of different methodologies have helped to address this shortcoming, but much work remains. In this paper, I address some of the instrument, reagent, and analysis considerations relevant to measurement of individual EVs in flow, with the aim of clarifying a path to quantitative and standardized measurement of these interesting and potentially important biological nanoparticles.
Collapse
|
11
|
High-throughput single-cell analysis of low copy number β-galactosidase by a laboratory-built high-sensitivity flow cytometer. Biosens Bioelectron 2013; 48:49-55. [DOI: 10.1016/j.bios.2013.03.078] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2012] [Revised: 03/28/2013] [Accepted: 03/29/2013] [Indexed: 01/05/2023]
|
12
|
Dada OO, Huge BJ, Dovichi NJ. Simplified sheath flow cuvette design for ultrasensitive laser induced fluorescence detection in capillary electrophoresis. Analyst 2012; 137:3099-101. [PMID: 22606689 PMCID: PMC3371152 DOI: 10.1039/c2an35321k] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We present a design for a sheath-flow cuvette that uses a relatively inexpensive quartz cuvette. The cuvette has a high optical quality square flow chamber that is fused to quartz tubes at each end. PEEK/TEFZEL fittings hold and seal the quartz flow chamber without putting strain on the cuvette. The performance of the cuvette is evaluated as a laser-induced fluorescence detector for capillary electrophoresis. The cuvette produces mass detection limits of 50 yoctomoles (30 copies) for 5-carboxyl tetramethylrhodamine (5 TAMRA SE) with a separation efficiency of 400,000 theoretical plates.
Collapse
Affiliation(s)
- Oluwatosin O Dada
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | | | | |
Collapse
|
13
|
Sarver SA, Keithley RB, Essaka DC, Tanaka H, Yoshimura Y, Palcic MM, Hindsgaul O, Dovichi NJ. Preparation and electrophoretic separation of Bodipy-Fl-labeled glycosphingolipids. J Chromatogr A 2012; 1229:268-73. [PMID: 22321948 PMCID: PMC3288550 DOI: 10.1016/j.chroma.2012.01.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2011] [Revised: 01/05/2012] [Accepted: 01/06/2012] [Indexed: 01/20/2023]
Abstract
Several glycosphingolipids were labeled with the fluorphore Bodipy-Fl and analyzed using capillary electrophoresis with laser-induced fluorescence detection. GM1-, LacCer-, and Cer-Bodipy-Fl were prepared through acylation using the N-hydroxysuccinimide ester of Bodipy-Fl. Several other glycosphingolipids including GT1a-, GD1a-, GM2-, GM3-, GD3-, and GlcCer-Bodipy-Fl were enzymatically synthesized. Micellar electrokinetic capillary chromatography with a TRIS/CHES/SDS/α-cyclodextrin buffer produced better separation than an established borate/deoxycholate/methyl-β-cyclodextrin buffer. The nine Bodipy-Fl-labeled glycosphingolipid standards were separated in under 5 min, theoretical plate counts were between 640,000 and 740,000, and the limit of detection was approximately 3 pM or 240 ymol analyte injected onto the capillary.
Collapse
Affiliation(s)
- Scott A. Sarver
- The University of Notre Dame, Department of Chemistry and Biochemistry, Notre Dame, IN 46556, USA
| | - Richard B. Keithley
- The University of Notre Dame, Department of Chemistry and Biochemistry, Notre Dame, IN 46556, USA
| | - David C. Essaka
- The University of Notre Dame, Department of Chemistry and Biochemistry, Notre Dame, IN 46556, USA
- The University of Washington, Department of Chemistry, Seattle, WA 98195
| | - Hidenori Tanaka
- Carlsberg Laboratory, Gamle Carlsberg Vej 10, DK-1799, Copenhagen-V, Denmark
| | - Yayoi Yoshimura
- Carlsberg Laboratory, Gamle Carlsberg Vej 10, DK-1799, Copenhagen-V, Denmark
| | - Monica M. Palcic
- Carlsberg Laboratory, Gamle Carlsberg Vej 10, DK-1799, Copenhagen-V, Denmark
| | - Ole Hindsgaul
- Carlsberg Laboratory, Gamle Carlsberg Vej 10, DK-1799, Copenhagen-V, Denmark
| | - Norman J. Dovichi
- The University of Notre Dame, Department of Chemistry and Biochemistry, Notre Dame, IN 46556, USA
| |
Collapse
|
14
|
Yang L, Zhou Y, Zhu S, Huang T, Wu L, Yan X. Detection and Quantification of Bacterial Autofluorescence at the Single-Cell Level by a Laboratory-Built High-Sensitivity Flow Cytometer. Anal Chem 2012; 84:1526-32. [DOI: 10.1021/ac2031332] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Lingling Yang
- The Key Laboratory
of Analytical Science, The Key Laboratory
for Chemical Biology of Fujian Province, Department of Chemical Biology,
College of Chemistry and Chemical Engineering, Xiamen University, Xiamen Fujian 361005, China
| | - Yingxing Zhou
- The Key Laboratory
of Analytical Science, The Key Laboratory
for Chemical Biology of Fujian Province, Department of Chemical Biology,
College of Chemistry and Chemical Engineering, Xiamen University, Xiamen Fujian 361005, China
| | - Shaobin Zhu
- The Key Laboratory
of Analytical Science, The Key Laboratory
for Chemical Biology of Fujian Province, Department of Chemical Biology,
College of Chemistry and Chemical Engineering, Xiamen University, Xiamen Fujian 361005, China
| | - Tianxun Huang
- The Key Laboratory
of Analytical Science, The Key Laboratory
for Chemical Biology of Fujian Province, Department of Chemical Biology,
College of Chemistry and Chemical Engineering, Xiamen University, Xiamen Fujian 361005, China
| | - Lina Wu
- The Key Laboratory
of Analytical Science, The Key Laboratory
for Chemical Biology of Fujian Province, Department of Chemical Biology,
College of Chemistry and Chemical Engineering, Xiamen University, Xiamen Fujian 361005, China
| | - Xiaomei Yan
- The Key Laboratory
of Analytical Science, The Key Laboratory
for Chemical Biology of Fujian Province, Department of Chemical Biology,
College of Chemistry and Chemical Engineering, Xiamen University, Xiamen Fujian 361005, China
| |
Collapse
|
15
|
Zhu S, Wang S, Yang L, Huang T, Yan X. Progress in the development of techniques based on light scattering for single nanoparticle detection. Sci China Chem 2011. [DOI: 10.1007/s11426-011-4313-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
16
|
Ramsay LM, Cermak N, Dada OO, Dovichi NJ. Capillary isoelectric focusing with pH 9.7 cathode for the analysis of gastric biopsies. Anal Bioanal Chem 2011; 400:2025-30. [PMID: 21461616 PMCID: PMC4429874 DOI: 10.1007/s00216-011-4926-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2010] [Revised: 03/11/2011] [Accepted: 03/16/2011] [Indexed: 10/18/2022]
Abstract
Capillary isoelectric focusing tends to suffer from poor reproducibility, particularly for the analysis of complex protein samples from cellular or tissue homogenates. This poor reproducibility appears to be associated with erratic variations in electroosmotic flow. One cause of electroosmotic flow variation is degradation of the capillary coating caused by the extremely basic solution commonly used during mobilization and focusing; this degradation of the capillary coating can be reduced by employing a CAPS mobilization buffer at pH 9. Another cause of variation is protein adsorption to the capillary wall, which causes an increase in electroosmotic flow. The effects of protein adsorption can be reduced by use of surfactants in the buffer and by employing an extremely low sample loading. We report the use of CAPS mobilization buffer in combination with an ultrasensitive laser-induced fluorescence detector for the reproducible analysis of ∼2 ng of protein from a Barrett's esophagus biopsy.
Collapse
Affiliation(s)
- Lauren M. Ramsay
- Department of Chemistry, University of Washington, Seattle WA 98195 USA
| | - Nathan Cermak
- Program in Computational and Systems Biology, Massachusetts Institute of Technology, Cambridge MA 02139 USA
| | - Oluwatosin O. Dada
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame IN 46617, USA
| | - Norman J. Dovichi
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame IN 46617, USA
| |
Collapse
|
17
|
Dada OO, Essaka DC, Hindsgaul O, Palcic MM, Prendergast J, Schnaar RL, Dovichi NJ. Nine orders of magnitude dynamic range: picomolar to millimolar concentration measurement in capillary electrophoresis with laser induced fluorescence detection employing cascaded avalanche photodiode photon counters. Anal Chem 2011; 83:2748-53. [PMID: 21410138 PMCID: PMC3072807 DOI: 10.1021/ac103374x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
The dynamic range of capillary electrophoresis analysis is ultimately limited by molecular shot noise at low concentrations and by concentration-induced band broadening at high concentrations. We report a system that approaches these fundamental limits. A laser-induced fluorescence detector is reported that employs a cascade of four fiber-optic beam splitters connected in series to generate a primary signal and four attenuated signals, each monitored by a single-photon counting avalanche photodiode. Appropriate scaling of the signals from the five photodiodes produces a linear optical calibration curve for 5-carboxyl-tetramethylrhodamine from the concentration detection limit of 1 pM to the upper limit of 1 mM. Mass detection limits are 120 yoctomoles (70 molecules) injected into the instrument. The very-wide dynamic range instrument was used to study the metabolic products of the fluorescently labeled glycosphingolipid tetramethylrhodamine labeled GM1 (GM1-TMR) produced by single cells isolated from the rat cerebellum.
Collapse
Affiliation(s)
- Oluwatosin O Dada
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | | | | | | | | | | | | |
Collapse
|
18
|
Ranasinghe RT, Brown T. Ultrasensitive fluorescence-based methods for nucleic acid detection: towards amplification-free genetic analysis. Chem Commun (Camb) 2011; 47:3717-35. [DOI: 10.1039/c0cc04215c] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
19
|
Ambrose WP, Goodwin PM, Jett JH, Johnson ME, Martin JC, Marrone BL, Schecker JA, Wilkerson CW, Keller RA, Haces A, Shih PJ, Harding JD. Application of Single Molecule Detection to DNA Sequencing and Sizing. ACTA ACUST UNITED AC 2010. [DOI: 10.1002/bbpc.19930971207] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
20
|
Whitmore CD, Essaka D, Dovichi NJ. Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection. Talanta 2009; 80:744-8. [PMID: 19836546 DOI: 10.1016/j.talanta.2009.07.060] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2009] [Revised: 07/26/2009] [Accepted: 07/27/2009] [Indexed: 10/20/2022]
Abstract
An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly three orders of magnitude dynamic range. The signal saturated at high analyte concentrations due to the dead time associated with the single-photon counting avalanche photodiode employed in the detector. The signal can be corrected for the detector dead time, providing an additional order of magnitude dynamic range. To further increase dynamic range, two fiber-optic beam-splitters were cascaded to generate a primary signal and two attenuated signals, each monitored by a single-photon counting avalanche photodiode. The combined signals from the three photodiodes are reasonably linear from the concentration detection limit of 3 pM to 10 microM, the maximum concentration investigated, a range of 3,000,000. Mass detection limits were 150 yoctomoles injected onto the capillary.
Collapse
Affiliation(s)
- Colin D Whitmore
- Department of Chemistry, University of Washington, Seattle, WA 98195-1700, USA.
| | | | | |
Collapse
|
21
|
Yang L, Zhu S, Hang W, Wu L, Yan X. Development of an Ultrasensitive Dual-Channel Flow Cytometer for the Individual Analysis of Nanosized Particles and Biomolecules. Anal Chem 2009; 81:2555-63. [DOI: 10.1021/ac802464a] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Lingling Yang
- Department of Chemical Biology, College of Chemistry and Chemical Engineering, The Key Laboratory for Chemical Biology of Fujian Province, The Key Laboratory of Analytical Science of the Ministry of Education, Xiamen University, Xiamen 361005, China
| | - Shaobin Zhu
- Department of Chemical Biology, College of Chemistry and Chemical Engineering, The Key Laboratory for Chemical Biology of Fujian Province, The Key Laboratory of Analytical Science of the Ministry of Education, Xiamen University, Xiamen 361005, China
| | - Wei Hang
- Department of Chemical Biology, College of Chemistry and Chemical Engineering, The Key Laboratory for Chemical Biology of Fujian Province, The Key Laboratory of Analytical Science of the Ministry of Education, Xiamen University, Xiamen 361005, China
| | - Lina Wu
- Department of Chemical Biology, College of Chemistry and Chemical Engineering, The Key Laboratory for Chemical Biology of Fujian Province, The Key Laboratory of Analytical Science of the Ministry of Education, Xiamen University, Xiamen 361005, China
| | - Xiaomei Yan
- Department of Chemical Biology, College of Chemistry and Chemical Engineering, The Key Laboratory for Chemical Biology of Fujian Province, The Key Laboratory of Analytical Science of the Ministry of Education, Xiamen University, Xiamen 361005, China
| |
Collapse
|
22
|
Ramsay LM, Dickerson JA, Dada O, Dovichi NJ. Femtomolar concentration detection limit and zeptomole mass detection limit for protein separation by capillary isoelectric focusing and laser-induced fluorescence detection. Anal Chem 2009; 81:1741-6. [PMID: 19206532 PMCID: PMC2765481 DOI: 10.1021/ac8025948] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Fluorescence tends to produce the lowest detection limits for most forms of capillary electrophoresis. Two issues have discouraged its use in capillary isoelectric focusing. The first issue is fluorescent labeling of proteins. Most labeling reagents react with lysine residues and convert the cationic residue to a neutral or anionic product. At best, these reagents perturb the isoelectric point of the protein. At worse, they convert each protein into hundreds of different fluorescent products that confound analysis. The second issue is the large background signal generated by impurities within commercial ampholytes. This background signal is particularly strong when excited in the blue portion of the spectrum, which is required by many common fluorescent labeling reagents. This paper addresses these issues. For labeling, we employ Chromeo P540, which is a fluorogenic reagent that converts cationic lysine residues to cationic fluorescent products. The reaction products are excited in the green, which reduces the background signal generated by impurities present within the ampholytes. To further reduce the background signal, we photobleach ampholytes with high-power photodiodes. Photobleaching reduced the noise in the ampholyte blank by an order of magnitude. Isoelectric focusing performed with photobleached pH 3-10 ampholytes produced concentration detection limits of 270 +/- 25 fM and mass detection limits of 150 +/- 15 zmol for Chromeo P540 labeled beta-lactoglobulin. Concentration detection limits were 520 +/- 40 fM and mass detection limits were 310 +/- 30 zmol with pH 4-8 ampholytes. A homogenate was prepared from a Barrett's esophagus cell line and separated by capillary isoelectric focusing, reproducibly generating dozens of peaks. The sample taken for the separation was equal to the labeled protein homogenate from three cells.
Collapse
Affiliation(s)
- Lauren M. Ramsay
- Department of Chemistry, University of Washington, Seattle, WA 98195
| | - Jane A. Dickerson
- Department of Chemistry, University of Washington, Seattle, WA 98195
| | - Oluwatosin Dada
- Department of Chemistry, University of Washington, Seattle, WA 98195
| | - Norman J. Dovichi
- Department of Chemistry, University of Washington, Seattle, WA 98195
| |
Collapse
|
23
|
Feng J, Arriaga EA. Quantification of carbonylated proteins in rat skeletal muscle mitochondria using capillary sieving electrophoresis with laser-induced fluorescence detection. Electrophoresis 2008; 29:475-82. [PMID: 18064596 DOI: 10.1002/elps.200700262] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Carbonyl-modified proteins are markers of oxidative damage. Here, we report a new method for detecting and quantifying carbonylated proteins by capillary sieving electrophoresis (CSE) with LIF detection (CSE-LIF). Alexa 488 hydrazide is used for the specific labeling of carbonyls while 3-(2-furoyl) quinoline-2-carboxaldehyde (FQ) is used for protein labeling. BSA subjected to metal-catalyzed oxidation is used to optimize the labeling reactions, confirm the separation power of CSE, and characterize the response of the LIF detector. The method is capable of detecting femtomole (fmol) amounts of carbonyls in proteins with molecular masses ranging from 26 to 30 kDa. Using this method, we determined that mitochondrial proteins isolated from skeletal muscle contains 2.1 +/- 0.1 (average +/- SD; n = 3) nmol carbonyl/mg protein. The methodology described here should be compatible with the analysis of single cells and needle biopsies taken from oxidative stress animal models.
Collapse
Affiliation(s)
- Juan Feng
- Department of Biomedical Engineering, University of Minnesota, Twin City, MN 55455, USA
| | | |
Collapse
|
24
|
Habbersett RC, Naivar MA, Woods TA, Goddard GR, Graves SW. Evaluation of a green laser pointer for flow cytometry. Cytometry A 2007; 71:809-17. [PMID: 17712796 DOI: 10.1002/cyto.a.20454] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Flow cytometers typically incorporate expensive lasers with high-quality (TEM00) output beam structure and very stable output power, significantly increasing system cost and power requirements. Red diode lasers minimize power consumption and cost, but limit fluorophore selection. Low-cost DPSS laser pointer modules could possibly offer increased wavelength selection but presumed emission instability has limited their use. A $160 DPSS 532 nm laser pointer module was first evaluated for noise characteristics and then used as the excitation light source in a custom-built flow cytometer for the analysis of fluorescent calibration and alignment microspheres. Eight of ten modules tested were very quiet (RMS noise < or = 0.6% between 0 and 5 MHz). With a quiet laser pointer module as the light source in a slow-flow system, fluorescence measurements from alignment microspheres produced CVs of about 3.3%. Furthermore, the use of extended transit times and < or =1 mW of laser power produced both baseline resolution of all 8 peaks in a set of Rainbow microspheres, and a detection limit of <20 phycoerythrin molecules per particle. Data collected with the transit time reduced to 25 micros (in the same instrument but at 2.4 mW laser output) demonstrated a detection limit of approximately 75 phycoerythrin molecules and CVs of about 2.7%. The performance, cost, size, and power consumption of the tested laser pointer module suggests that it may be suitable for use in conventional flow cytometry, particularly if it were coupled with cytometers that support extended transit times.
Collapse
Affiliation(s)
- Robert C Habbersett
- The National Flow Cytometry Resource, Bioscience Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
| | | | | | | | | |
Collapse
|
25
|
Affiliation(s)
- Karel Klepárník
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, CZ-602 00 Brno, Czech Republic
| | - Petr Boček
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, CZ-602 00 Brno, Czech Republic
| |
Collapse
|
26
|
Goddard GR, Sanders CK, Martin JC, Kaduchak G, Graves SW. Analytical Performance of an Ultrasonic Particle Focusing Flow Cytometer. Anal Chem 2007; 79:8740-6. [DOI: 10.1021/ac071402t] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Gregory R. Goddard
- National Flow Cytometry Resource, Mail Stop M888, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545
| | - Claire K. Sanders
- National Flow Cytometry Resource, Mail Stop M888, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545
| | - John C. Martin
- National Flow Cytometry Resource, Mail Stop M888, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545
| | - Gregory Kaduchak
- National Flow Cytometry Resource, Mail Stop M888, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545
| | - Steven W. Graves
- National Flow Cytometry Resource, Mail Stop M888, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545
| |
Collapse
|
27
|
Sobhani K, Michels DA, Dovichi NJ. Sheath-flow cuvette for high-sensitivity laser-induced fluorescence detection in capillary electrophoresis. APPLIED SPECTROSCOPY 2007; 61:777-9. [PMID: 17697473 DOI: 10.1366/000370207781393208] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The sheath-flow cuvette is a key component in a high-sensitivity post-column laser-induced fluorescence detector for capillary electrophoresis. Most designs are based on commercial cuvettes originally manufactured for use in a flow cytometer. In these devices, a quartz flow chamber is held in a stainless-steel fixture that is difficult to machine and subjects the cuvette to a torque when sealed, which frequently leads to damage of the flow chamber. In this report we present a design for a cuvette that may easily be constructed. This design uses compression to hold and seal the quartz flow chamber without applying torque. The system produces detection limits (3sigma) of 115 yoctomoles (70 copies) for FQ-labeled carbonic anhydrase.
Collapse
Affiliation(s)
- Kimia Sobhani
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, USA
| | | | | |
Collapse
|
28
|
Sýkora J, Kaiser K, Gregor I, Bönigk W, Schmalzing G, Enderlein J. Exploring fluorescence antibunching in solution to determine the stoichiometry of molecular complexes. Anal Chem 2007; 79:4040-9. [PMID: 17487973 DOI: 10.1021/ac062024f] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Fluorescence antibunching is a well-known technique for determining the number of independent emitters per molecule or molecular complex. It was rarely applied to autofluorescent proteins due to the necessity of collecting large numbers of fluorescence photons from a single molecule, which is usually impossible to achieve with rather photolabile autofluorescent proteins. Here, we measure fluorescence antibunching on molecules in solution, allowing us to accumulate data over a large number of molecules. We use that method for determining an average stoichiometry of molecular complexes. The proposed method is absolute in the sense that it does not need any calibration or referencing. We develop the necessary theoretical background and check the method on pure dye solutions and on molecular complexes with known stoichiometry.
Collapse
Affiliation(s)
- Jan Sýkora
- Institute for Neuroscience and Biophysics 1, Forschungszentrum Jülich, D 52425 Jülich, Germany
| | | | | | | | | | | |
Collapse
|
29
|
Kraly JR, Jones MR, Gomez DG, Dickerson JA, Harwood MM, Eggertson M, Paulson TG, Sanchez CA, Odze R, Feng Z, Reid BJ, Dovichi NJ. Reproducible two-dimensional capillary electrophoresis analysis of Barrett's esophagus tissues. Anal Chem 2006; 78:5977-86. [PMID: 16944874 PMCID: PMC2597506 DOI: 10.1021/ac061029+] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
We have constructed a high-speed, two-dimensional capillary electrophoresis system with a compact and high-sensitivity fluorescence detector. This instrument is used for the rapid and reproducible separations of Barrett's esophagus tissue homogenates. Proteins and biogenic amines are labeled with the fluorogenic reagent 3-(2-furoyl)quinoline-2-carboxaldehyde. Labeled biomolecules are separated sequentially in two capillaries. The first capillary employs capillary sieving electrophoresis using a replaceable sieving matrix. Fractions are successively transferred to a second capillary where they undergo additional separation by micellar electrokinetic capillary chromatography. The comprehensive two-dimensional separation requires 60 min. Within-day migration time reproducibility is better than 1% in both dimensions for the 50 most intense features. Between-day migration time precision is 1.3% for CSE and better than 0.6% for MECC. Biopsies were obtained from the squamous epithelium in the proximal tubular esophagus, Barrett's epithelium from the distal esophagus, and fundus region of the stomach from each of three Barrett's esophagus patients with informed consent. We identified 18 features from the homogenate profiles as biogenic amines and amino acids. For each of the patients, Barrett's biopsies had more than 5 times the levels of phenylalanine and alanine as compared to squamous tissues. The patient with high-grade dysplasia shows the highest concentrations for 13 of the amino acids across all tissue types. Concentrations of glycine are 40 times higher in squamous biopsies compared to Barrett's and fundal biopsies from the patient with high-grade dysplasia. These results suggest that two-dimensional capillary electrophoresis may be of value for the rapid characterization of endoscopic and surgical biopsies.
Collapse
Affiliation(s)
- James R Kraly
- Department of Chemistry, University of Washington, Seattle, WA 98195-1700, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Fazal MA, Palmer VR, Dovichi NJ. Analysis of differential detergent fractions of an AtT-20 cellular homogenate using one- and two-dimensional capillary electrophoresis. J Chromatogr A 2006; 1130:182-9. [PMID: 16781720 DOI: 10.1016/j.chroma.2006.05.053] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2006] [Revised: 05/09/2006] [Accepted: 05/10/2006] [Indexed: 12/01/2022]
Abstract
Differential detergent fractionation was used to sequentially extract cytosolic, membrane, nuclear, and cytoskeletal fractions from AtT-20 cells. Extracted components were denatured by sodium dodecyl sulfate (SDS) and then labeled with the fluorogenic reagent 3-(2-furoyl) quinoline-1-carboxaldehyde. Both capillary sieving electrophoresis (CSE) and micellar electrokinetic capillary chromatography (MECC) were used to separate labeled components by one-dimensional (1D) electrophoresis. Labeled components were also separated by two-dimensional (2D) capillary electrophoresis; CSE was employed in the first dimension and MECC in the second dimension. Roughly 150 fractions were transferred from the first to the second capillary for this comprehensive analysis in 2.5 h.
Collapse
Affiliation(s)
- Md Abul Fazal
- Department of Chemistry, University of Washington, Seattle, 98195-1700, USA
| | | | | |
Collapse
|
31
|
Dittrich PS, Manz A. Single-molecule fluorescence detection in microfluidic channels—the Holy Grail in μTAS? Anal Bioanal Chem 2005; 382:1771-82. [PMID: 16075229 DOI: 10.1007/s00216-005-3335-9] [Citation(s) in RCA: 119] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2005] [Revised: 05/12/2005] [Accepted: 05/19/2005] [Indexed: 10/25/2022]
Abstract
Both single-molecule detection (SMD) methods and miniaturization technologies have developed very rapidly over the last ten years. By merging these two techniques, it may be possible to achieve the optimal requirements for the analysis and manipulation of samples on a single molecule scale. While miniaturized structures and channels provide the interface required to handle small particles and molecules, SMD permits the discovery, localization, counting and identification of compounds. Widespread applications, across various bioscience/analytical science fields, such as DNA-analysis, cytometry and drug screening, are envisaged. In this review, the unique benefits of single fluorescent molecule detection in microfluidic channels are presented. Recent and possible future applications are discussed.
Collapse
Affiliation(s)
- Petra S Dittrich
- Department of Miniaturization, Institute for Analytical Sciences (ISAS), Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany.
| | | |
Collapse
|
32
|
Ramanathan A, Huff EJ, Lamers CC, Potamousis KD, Forrest DK, Schwartz DC. An integrative approach for the optical sequencing of single DNA molecules. Anal Biochem 2005; 330:227-41. [PMID: 15203328 DOI: 10.1016/j.ab.2004.03.029] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2003] [Indexed: 11/18/2022]
Abstract
A new approach for optically sequencing ensembles of single DNA molecules using DNA polymerase to mediate the consecutive incorporation of fluorochrome-labeled nucleotides into an array of large single DNA molecules is presented. The approach utilizes cycles of labeled fluorochrome addition, detection to count incorporations, and bleaching to reset the counter. These additions are imaged and analyzed to estimate the number of labeled additions and to correlate them on a per-locus basis along DNA backbones. Initial studies used precisely labeled polymerase chain reaction products to aid the development and validation of simple models of fluorochrome point spread functions within the imaging system. In complementary studies, nucleotides labeled with the fluorochrome R110 were incorporated into surface-elongated lambda DNA, and fluorescent signals corresponding to the addition of R110-dUTP were counted and assigned precise loci along DNA backbones. The labeled DNAs were then subjected to photobleaching and to a second cycle of addition of R110-labeled nucleotides-a second round of additions was correlated with the first to establish strings of addition histories among the ensemble of largely double-stranded templates. These results confirm the basic operational validity of this approach and point the way to the development of a practical system for optical sequencing.
Collapse
Affiliation(s)
- Arvind Ramanathan
- Laboratory for Molecular and Computational Genomics, Department of Chemistry, Laboratory of Genetics, University of Wisconsin-Madison, UW-Biotechnology Center, 425 Henry Mall, Madison, WI 53706, USA
| | | | | | | | | | | |
Collapse
|
33
|
Fluorescence detection in capillary electrophoresis. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/s0166-526x(05)45006-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
34
|
Hu S, Michels DA, Fazal MA, Ratisoontorn C, Cunningham ML, Dovichi NJ. Capillary Sieving Electrophoresis/Micellar Electrokinetic Capillary Chromatography for Two-Dimensional Protein Fingerprinting of Single Mammalian Cells. Anal Chem 2004; 76:4044-9. [PMID: 15253641 DOI: 10.1021/ac0498314] [Citation(s) in RCA: 92] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We have developed a two-dimensional capillary electrophoresis method for the study of protein expression in single mammalian cells. The first-dimension capillary contains an SDS-pullulan buffer system to perform capillary sieving electrophoresis, which separates proteins based on molecular weight. The second-dimension capillary contains an SDS buffer for micellar electrokinetic capillary chromatography. After a 6-min-long preliminary separation, fractions from the first capillary are successively transferred to a second capillary, where they undergo further separation by MECC. Over 100 transfers and second-dimension separations are performed over an approximately 3.5-h-long period. We demonstrate this technology by generating protein fingerprints from single native MC3T3-E1 osteoprogenitor cells and MC3T3-E1 cells transfected with the human transcription regulator TWIST. We also present single-cell protein fingerprints from MCF-7 breast cancer cells before and following treatment to induce apoptosis.
Collapse
Affiliation(s)
- Shen Hu
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | | | | | | | | | | |
Collapse
|
35
|
Földes-Papp Z, Demel U, Tilz GP. A new concept for ultrasensitive fluorescence measurements of molecules in solution and membrane:. J Immunol Methods 2004; 286:1-11. [PMID: 15087217 DOI: 10.1016/j.jim.2004.01.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2003] [Revised: 12/14/2003] [Accepted: 01/08/2004] [Indexed: 11/17/2022]
Abstract
Just because there is an average of one molecule in the observation volume of a solution or membrane (single-phase), one cannot say that this is an individual molecule since many different single molecules measured one by one or the same single, individual molecule not leaving the detection volume on time average can cause a single-molecule event. The latter case is of interest and allows the continuous observation of one and the same single molecule without averaging over many 'different' single molecules. For the first time a universal theoretical and experimental framework is presented for the continuous observation of the same single, individual molecule without immobilization, hydrodynamic flow, or burst size histograms of fluorescence intensity traces. In this original article, the stochastic approach is derived and its main characteristics are demonstrated with the free fluorophore rhodamine-green in solution for simpler experimental realization. Single (solution)-phase single-molecule fluorescence auto- (or two-color cross-) correlation spectroscopy (SPSM-FCS) is used as a specific application in order to count the absolute number of molecules in the observation volume. The absolute number of molecules, the diffusion coefficient of the single fluorescent molecule, the lower limit of distance, and the molar concentration of the bulk phase (solution) were directly obtained from the measured auto- or (cross)-correlation curves of the SPSM-FCS experiments. For this purpose, the detection volume that was measured was less then 1 fl (10(-15) l). Then, a concentration of the bulk solution was chosen in such a way that the probability of detecting more than one molecule in the detection volume was very small. The Poisson probability was experimentally determined for the absolute number of molecules depending upon a specified bulk concentration. From the diffusion coefficient of the molecule, it was found that the probability of the molecule diffusing out of the probe volume during the measurements was negligibly small.
Collapse
Affiliation(s)
- Zeno Földes-Papp
- Clinical Immunology and Jean Dausset Laboratory, Graz University Medical School and Hospital, Auenbruggerplatz 8, A-8036 Graz, LKH, Austria.
| | | | | |
Collapse
|
36
|
Böhmer M, Enderlein J. Fluorescence spectroscopy of single molecules under ambient conditions: methodology and technology. Chemphyschem 2003; 4:793-808. [PMID: 12961976 DOI: 10.1002/cphc.200200565] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This review presents an overview of the fluorescence detection and spectroscopy of single molecules (SMS) in liquids and on surfaces under ambient conditions. The various techniques of SMS, such as confocal epifluorescence detection and wide-field imaging are presented and discussed, together with the different methods of data analysis such as fluorescence correlation spectroscopy and burst-by-burst analysis. Selected applications of the various techniques in physics, chemistry, and biology are described.
Collapse
Affiliation(s)
- Martin Böhmer
- IBI-1, Forschungszentrum Jülich 52425 Jülich, Germany
| | | |
Collapse
|
37
|
Földes-Papp Z, Demel U, Domej W, Tilz GP. A new dimension for the development of fluorescence-based assays in solution: from physical principles of FCS detection to biological applications. Exp Biol Med (Maywood) 2002; 227:291-300. [PMID: 11976399 DOI: 10.1177/153537020222700501] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Ultrasensitive detection methods such as laser-induced fluorescence represent the current state-of-the-art in analytics. Single-molecule detection in solution has received a remarkable amount of attention in the last few years because of its applicability to life sciences. Studies have been performed on the fundamentals of the detection processes themselves and on some biological systems. Fluorescence correlation spectroscopy (FCS) is the link for ultrasensitive multicomponent analysis, showing possibilities for experiments on molecular interactions. Based on the theoretical background of FCS, this article gives full explanation of FCS and an update of highlights in experimental biology and medicine studied by FCS. We focus on a repertoire of diverse immunoglobulin specificities, a ribosome display system, single-molecule DNA sequencing, and a mutant enzyme generated by random mutagenesis of amino acids. We describe the usefulness and the enormous potential of the methodology. Further, this contribution clearly indicates that FCS is a valuable tool for solution-phase single-molecule (SPSM) experiments in immunobiology and medicine. In experiments with the Goodpasture autoantibody, we worked out conditions for the design of experiments on a complex single molecule in solution. The possibility to use SPSM-FCS as a quantitation methodology opens up other important applications beyond the scope of this article. Original results extending the published studies are presented for the rational foundation of SPSM-FCS. In this original contribution, we deal with experimental systems for biology and medicine where the number of molecules in solution is very small. This article is mandatory for gaining confidence in the interpretation of experimental SPSM-FCS results on the selfsame, individual single molecule in solution.
Collapse
Affiliation(s)
- Zeno Földes-Papp
- Clinical Immunology and Jean Dausset Laboratory, Graz University Medical School and Hospital, Auenbruggerplatz 8, A-8036 Graz, LKH, Austria.
| | | | | | | |
Collapse
|
38
|
Brakmann S, Löbermann S. Hochgradige Markierung von DNA: Herstellung und Charakterisierung des Substrats für eine Einzelmolekül-Sequenzierung. Angew Chem Int Ed Engl 2001. [DOI: 10.1002/1521-3757(20010417)113:8<1473::aid-ange1473>3.0.co;2-t] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
39
|
Brakmann S, Löbermann S. High-Density Labeling of DNA: Preparation and Characterization of the Target Material for Single-Molecule Sequencing. Angew Chem Int Ed Engl 2001. [DOI: 10.1002/1521-3773(20010417)40:8%3c1427::aid-anie1427%3e3.0.co;2-t] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
40
|
Brakmann S, Löbermann S. High-Density Labeling of DNA: Preparation and Characterization of the Target Material for Single-Molecule Sequencing. Angew Chem Int Ed Engl 2001; 40:1427-1429. [PMID: 29712349 DOI: 10.1002/1521-3773(20010417)40:8<1427::aid-anie1427>3.0.co;2-t] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2000] [Indexed: 11/07/2022]
Affiliation(s)
- Susanne Brakmann
- Evotec Biosystems AG Schnackenburgallee 114, 22525 Hamburg (Germany) Fax: (+49) 551-201-1435
| | - Sylvia Löbermann
- Max Planck Institute for Biophysical Chemistry Am Fassberg, 37077 Göttingen (Germany)
| |
Collapse
|
41
|
Földes-Papp Z, Angerer B, Ankenbauer W, Rigler R. Fluorescent high-density labeling of DNA: error-free substitution for a normal nucleotide. J Biotechnol 2001; 86:237-53. [PMID: 11257534 DOI: 10.1016/s0168-1656(00)00416-8] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The enzymatic incorporation of deoxyribonucleoside triphosphates by a thermostable, 3'-->5' exonuclease deficient mutant of the Tgo DNA polymerase was studied for PCR-based high-density labeling of 217-bp "natural" DNA in which fluorescent-dUTP was substituted completely for the normal dTTP. The amplified DNA carried two different sorts of tethered dye molecules. The rhodamine-green was used for internal tagging of the DNA. Since high-density incorporation of rhodamine-green-X-dUTP led to a substantial reduction (quenching) of the rhodamine-green fluorescence, a second "high" quantum yield label, Cy5, was inserted via a 5'-tagged primer in order to identify the two-color product. A theoretical concept of fluorescence auto- and cross-correlation spectroscopy developed here was applied to quantify the DNA sequence formed in terms of both the number of two-color fluorescent molecules and the number of covalently incorporated rhodamine-green-X-dUMP residues. The novel approach allowed to separate optically the specific DNA product. After complete, exonucleolytic degradation of the two-color DNA we determined 82-88 fluorescent U* labels incorporated covalently out of 92 maximum possible U* incorporations. The heavily green-labeled DNA was then isolated by preparative mobility-shift electrophoresis, re-amplified in a subsequent PCR with normal deoxyribonucleoside triphosphates, and re-sequenced. By means of this novel methodology for analyzing base-specific incorporations that was first developed here, we found that all fluorescent nucleotides and the normal nucleotides were incorporated at the correct positions. The determined labeling efficiency of 0.89-0.96 indicated that a fraction of the substrate analog was not bearing the fluorophore. The results were used to guide developments in single-molecule DNA sequencing. The labeling strategy (principal approach) for PCR-based high-density tagging of DNA, which included an appropriate thermostable DNA polymerase and a suitable fluorescent dye-dNTP, was developed here.
Collapse
Affiliation(s)
- Z Földes-Papp
- Department of Medical Biophysics, MBB, Karolinska Institute, S-17177 Stockholm, Sweden.
| | | | | | | |
Collapse
|
42
|
Fluorescence Correlation Spectroscopy in Nucleic Acid Analysis. SPRINGER SERIES IN CHEMICAL PHYSICS 2001. [DOI: 10.1007/978-3-642-59542-4_3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
43
|
|
44
|
Garguilo MG, Thomas DH, Anex DS, Rakestraw DJ. Laser-induced dispersed fluorescence detection of polycyclic aromatic compounds in soil extracts separated by capillary electrochromatography. J Chromatogr A 2000; 883:231-48. [PMID: 10910217 DOI: 10.1016/s0021-9673(00)00409-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) and nitrogen containing aromatic compounds (NCACs) are characterized in soil extracts and laboratory standards by capillary electrochromatography (CEC) with laser-induced dispersed fluorescence (LIDF) detection using a liquid-nitrogen cooled charge-coupled device detector. The LIDF detection technique provides information on compound identity and, when coupled with the high separation efficiencies of the CEC technique, proves useful in the analysis of complex mixtures. Differences in fluorescence spectra also provide a means of identifying co-eluting compounds by using deconvolution algorithms. Detection limits range from 0.5 to 96x10(-10) M for selected PAHs and 0.9-3.7x10(-10) M for selected NCACs. Soil extracts are also injected onto the CEC column to evaluate chromatographic method performance with respect to complex samples and the ability to withstand exposure to environmental samples.
Collapse
Affiliation(s)
- M G Garguilo
- Sandia National Laboratories, Livermore, CA 94551-0969, USA
| | | | | | | |
Collapse
|
45
|
Ambrose WP, Goodwin PM, Jett JH, Van Orden A, Werner JH, Keller RA. Single molecule fluorescence spectroscopy at ambient temperature. Chem Rev 1999; 99:2929-56. [PMID: 11749506 DOI: 10.1021/cr980132z] [Citation(s) in RCA: 264] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- W P Ambrose
- Chemical Science and Technology Division and Life Sciences Division, MS M888, Los Alamos National Laboratory, Los Alamos, New Mexico 87545
| | | | | | | | | | | |
Collapse
|
46
|
Abstract
Recent advances in single-molecule detection and single-molecule spectroscopy at room temperature by laser-induced fluorescence offer new tools for the study of individual macromolecules under physiological conditions. These tools relay conformational states, conformational dynamics, and activity of single biological molecules to physical observables, unmasked by ensemble averaging. Distributions and time trajectories of these observables can therefore be measured during a reaction without the impossible need to synchronize all the molecules in the ensemble. The progress in applying these tools to biological studies with the use of fluorophores that are site-specifically attached to macromolecules is reviewed.
Collapse
Affiliation(s)
- S Weiss
- Materials Sciences and Physical Biosciences Divisions, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.
| |
Collapse
|
47
|
Wu Z, Tong WG. Absorbance detection of amino acids by laser wave mixing in microbore liquid chromatography. J Chromatogr A 1998; 805:63-9. [PMID: 9618915 DOI: 10.1016/s0021-9673(98)00022-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Nonlinear optical phase conjugation by degenerate four-wave mixing is demonstrated as a sensitive "absorbance" detection method for microbore high-performance liquid chromatography. An argon ion laser operating at the 488-nm line is used as the excitation light source to generate the wave-mixing signal for dabsyl-labeled amino acids. Advantages of the nonlinear laser detection method include: virtually 100% optical signal collection efficiency, generation of the signal in the form of a coherent laser beam, signal measurement against a virtually dark background, reliable detection of small absorbance values, excellent detection sensitivity for both fluorescing and non-fluorescing analytes, relatively simple one-color one-laser optical setup, and low power or energy requirements for continuous-wave or pulsed lasers. Using our one-laser one-color nonlinear laser detector for "absorbance" measurements in liquid chromatography, we report a crude preliminary "injected" detection limit of 780 fmol for glycine.
Collapse
Affiliation(s)
- Z Wu
- Department of Chemistry, San Diego State University, CA 92182, USA
| | | |
Collapse
|
48
|
Affiliation(s)
- Stephen C. Jacobson
- Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, Tennessee 37831-6142
| | - J. Michael Ramsey
- Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, Tennessee 37831-6142
| |
Collapse
|
49
|
Wu Z, Tong WG. Sensitive absorbance detection method for capillary electrophoresis based on laser wave-mixing. J Chromatogr A 1997; 773:291-8. [PMID: 9228800 DOI: 10.1016/s0021-9673(97)00185-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Forward-scattering four-wave mixing is demonstrated as a sensitive absorbance detection method for capillary electrophoresis, using an argon ion laser operating at 457.9 nm. Since this four-wave mixing laser technique utilizes only two input laser beams, it offers important advantages, including ease of optical alignment, high wave-mixing efficiency and low excitation power requirements. In addition, since the analytical signal is a laser-like coherent beam, highly efficient optical signal detection can be performed with minimum optical background noise. Excellent detection sensitivity and short absorption path lengths, and hence, small detector probe volumes, are some of the useful features this absorbance detection method offers for on-column detection of both fluorescing and non-fluorescing analytes in capillary electrophoresis and liquid chromatography. Preliminary "detected" concentration detection limit of 8.5.10(-8) M, mass detection limit of 13 amol and an absorbance-unit detection limit of 1.35.10(-5) AU are determined for dabsyl-glycine using this absorbance detection method.
Collapse
Affiliation(s)
- Z Wu
- Department of Chemistry, San Diego State University, CA 92182, USA
| | | |
Collapse
|
50
|
Abstract
Continuous monitoring of submillisecond free-solution dynamics of individual rhodamine-6G molecules and 30-base single-stranded DNA tagged with rhodamine was achieved. Fluorescence images were recorded from the same set of isolated molecules excited either through the evanescent field at the quartz-liquid interface or as a thin layer of solution defined by micron-sized wires, giving diffraction-limited resolution of inter-connected attoliter volume elements. The single-molecule diffusion coefficients were smaller and the unimolecular photodecomposition lifetimes were longer for the dye-DNA covalent complex as compared with those of the dye molecule itself. Unlike bulk studies, stochastic behavior was found for individual molecules of each type, and smaller diffusion coefficients were observed.
Collapse
Affiliation(s)
- X H Xu
- Ames Laboratory-U.S. Department of Energy, IA 50011, USA
| | | |
Collapse
|