1
|
Stevens CE, Costello JT, Tipton MJ, Walker EF, Gould AAM, Young JS, Lee BJ, Williams TB, Myers FA, Corbett J. Effect of condensed heat acclimation on thermophysiological adaptations, hypoxic cross-tolerance, exercise performance, and deacclimation. J Appl Physiol (1985) 2025; 138:634-650. [PMID: 39819118 DOI: 10.1152/japplphysiol.00775.2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2024] [Revised: 10/23/2024] [Accepted: 01/03/2025] [Indexed: 01/19/2025] Open
Abstract
Short duration heat acclimation (HA) (≤5 daily heat exposures) elicits incomplete adaptation compared with longer interventions, possibly due to the lower accumulated thermal "dose." It is unknown if matching thermal "dose" over a shorter timescale elicits comparable adaptation to a longer intervention. Using a parallel-groups design, we compared: 1) "condensed" HA (CHA; n = 17 males) consisting of 4 × 75 min·day-1 heat exposures [target rectal temperature (Trec) = 38.5 °C] for two consecutive days, with 2) "traditional" HA (THA; n = 15 males) consisting of 1 × 75 min·day-1 heat exposure (target Trec = 38.5°C) for eight consecutive days. Physiological responses to exercise heat stress, hypoxia, and normoxic exercise performance were evaluated pre- and postintervention. Thermal (Trec over final 45 min: CHA = 38.45 ± 0.17°C, THA = 38.53 ± 0.13°C, P = 0.126) and cardiovascular strain were not different during interventions, indicating similar thermal "dose," although CHA had lower sweating rate, higher starting Trec, and greater inflammation, gastrointestinal permeability, and renal stress (P < 0.05). However, CHA elicited an array of thermophysiological adaptations that did not differ from THA [reduced indices of peak thermal (e.g., Δ peak Trec CHA = -0.28 ± 0.26°C, THA = -0.36 ± 0.17°C, P = 0.303) and cardiovascular strain, inflammation, and renal stress; blood and plasma volume expansion; improved perceptual indices], although improvements in resting thermal strain (e.g., Δ resting Trec CHA = -0.14 ± 0.21°C, THA = -0.35 ± 0.29°C, P = 0.027) and sweating rate were less with CHA. Both interventions improved aspects of hypoxic tolerance, but effects on temperate normoxic exercise indices were limited. The diminished thermal strain was well-maintained over a 22-day decay period. In conclusion, CHA could represent a viable acclimation option for time-restricted young healthy males preparing for a hot, and possibly high-altitude, environment.NEW & NOTEWORTHY This study has shown, for the first time, that a novel condensed heat acclimation program can elicit an array of thermophysiological adaptations, many of which do not differ from traditional heat acclimation. These findings suggest that accumulated thermal "dose" is an important factor contributing to the adaptive responses to heat stress and that condensed heat acclimation may represent a viable option for time-restricted individuals (e.g., military personnel, firefighters, and athletes) preparing to enter a hot environment.
Collapse
Affiliation(s)
- Charlotte E Stevens
- Extreme Environments Laboratory, School of Psychology, Sport and Health Sciences, University of Portsmouth, Portsmouth, United Kingdom
- Occupational Performance Research Group, University of Chichester, Chichester, United Kingdom
| | - Joseph T Costello
- Extreme Environments Laboratory, School of Psychology, Sport and Health Sciences, University of Portsmouth, Portsmouth, United Kingdom
| | - Michael J Tipton
- Extreme Environments Laboratory, School of Psychology, Sport and Health Sciences, University of Portsmouth, Portsmouth, United Kingdom
| | - Ella F Walker
- Defence Science and Technology Laboratory, Porton Down Salisbury, United Kingdom
| | - Alex A M Gould
- Extreme Environments Laboratory, School of Psychology, Sport and Health Sciences, University of Portsmouth, Portsmouth, United Kingdom
| | - John S Young
- National Horizons Centre, Teesside University, Darlington, United Kingdom
| | - Ben J Lee
- Occupational and Environmental Physiology Group, Centre for Sport, Exercise and Life Sciences, Faculty of Health and Life Sciences, Coventry University, Coventry, United Kingdom
| | - Thomas B Williams
- Extreme Environments Laboratory, School of Psychology, Sport and Health Sciences, University of Portsmouth, Portsmouth, United Kingdom
| | - Fiona A Myers
- School of the Environment and Life Sciences, University of Portsmouth, Portsmouth, United Kingdom
| | - Jo Corbett
- Extreme Environments Laboratory, School of Psychology, Sport and Health Sciences, University of Portsmouth, Portsmouth, United Kingdom
| |
Collapse
|
2
|
Brown HA, Clark B, Périard JD. Reliability and validity of the MX3 portable sweat sodium analyser during exercise in warm conditions. Eur J Appl Physiol 2024; 124:2153-2160. [PMID: 38430262 PMCID: PMC11199257 DOI: 10.1007/s00421-024-05447-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Accepted: 02/10/2024] [Indexed: 03/03/2024]
Abstract
PURPOSE Accurately measuring sweat sodium concentration ([Na+]) in the field is advantageous for coaches, scientists, and dieticians looking to tailor hydration strategies. The MX3 hydration testing system is a new portable analyser that uses pre-calibrated biosensors to measure sweat [Na+]. This study aimed to assess the validity and reliability of the MX3 hydration testing system. METHODS Thirty-one (11 females) recreationally active participants completed one experimental trial. During this trial, participants exercised at a self-selected pace for 45 min in a warm environment (31.5 ± 0.8 °C, 63.2 ± 1.3% relative humidity). Sweat samples were collected from three measurement sites using absorbent patches. The samples were then analysed for sweat [Na+] using both the MX3 hydration testing system and the Horiba LAQUAtwin-NA-11. The reliability of the MX3 hydration testing system was determined following two measurements of the same sweat sample. RESULTS The mean difference between measurements was 0.1 mmoL·L-1 (95% limits of agreement (LoA): - 9.2, 9.4). The analyser demonstrated a coefficient of variation (CV) of 5.6% and the standard error of measurement was 3.3 mmoL·L-1. When compared to the Horiba LAQUAtwin-NA-11, there was a mean difference of - 1.7 mmoL·L-1 (95% LoA: - 0.25 X ¯ , 0.25 X ¯ ) and the CV was 9.8%. CONCLUSION The MX3 hydration testing system demonstrated very good single-trial reliability, moderate agreement and a very good CV relative to the Horiba LAQUAtwin-Na-11. To further validate its performance, the MX3 hydration testing system should be compared with analytical techniques known for superior reliability and validity.
Collapse
Affiliation(s)
- Harry A Brown
- Research Institute for Sport and Exercise Science (UCRISE), University of Canberra, Bruce, Canberra, ACT, Australia
| | - Brad Clark
- Research Institute for Sport and Exercise Science (UCRISE), University of Canberra, Bruce, Canberra, ACT, Australia
| | - Julien D Périard
- Research Institute for Sport and Exercise Science (UCRISE), University of Canberra, Bruce, Canberra, ACT, Australia.
| |
Collapse
|
3
|
Suarez-Ortegón MF, Zea-León MDP, Astudillo-Gironza AM, Garzón S, Portela GF, Villarreal-Nieto OD. Sweat Rate, Sweat Sodium Losses, and Body Composition in Professional Male Soccer Players in Southwest Colombia. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:113. [PMID: 38256373 PMCID: PMC10819496 DOI: 10.3390/medicina60010113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 01/02/2024] [Accepted: 01/04/2024] [Indexed: 01/24/2024]
Abstract
Background and Objective: Dehydration and hyperhydration impact athletes' performance. Exploring the fluid balance concerning body composition might help estimate individual hydration requirements. This area of research, particularly regarding sodium losses, has been relatively understudied. We evaluated the sweat rate (SR), sweat sodium losses, and their relationship with body composition in professional soccer players in Cali, Colombia. Materials and Methods: Thirty-two male players, aged 24.3 (±5.2) years, from the Colombian main soccer league, underwent high-intensity training at 32 °C (with a relative humidity of 79%). The outcome variables included SR, calculated using weight loss and fluid intake; forearm sweat sodium concentration (FSCC), measured through the direct ion-selective electrode method; and estimated the predicted whole sweat sodium loss (PWSSL) in mmol. Predictor variables (body mass, fat, and muscle masses) were estimated using the Deborah Kerr anthropometry method. The association between predictors and outcomes was assessed using linear regression. Results: The mean FSCC, PWSSL, and SR were 26.7 ± 11.3 mmol/L, 43 ± 15.9 mmol/L, and 1.7 ± 0.5 L/h, respectively. Body mass positively predicted FSCC in unadjusted and age/fat-mass-adjusted models [Beta 1.28, 95% confidence interval (CI) 0.39-2.18, p = 0.006], and continued related to FSCC after adjustment for muscle mass with marginal significance [Beta 0.85, 95% CI -0.02 to 1.73, p = 0.056]. Muscle mass was associated with the PWSSL in unadjusted and age/fat-mass-adjusted models [Beta 2.42, 95% CI 0.58-4.26, p = 0.012] and sustained an association with marginal statistical significance after adjustment for body mass [Beta 1.86, 95% CI -0.35 to 4.09, p = 0.097]. Conclusions: Under hot tropical weather conditions, FSCC was relatively low among the players. Body mass was better associated with the FSSC, and muscle mass better related to the PWSSL. Body and muscle masses could be regarded as potential factors to be explored in the estimation of individual sodium needs. However, further studies are required to validate and contrast our findings.
Collapse
Affiliation(s)
- Milton Fabian Suarez-Ortegón
- Departamento de Alimentación y Nutrición, Facultad de Ciencias de La Salud, Pontificia Universidad Javeriana Seccional Cali, Cali 760021, Colombia;
| | - Maria del Pilar Zea-León
- Departamento de Alimentación y Nutrición, Facultad de Ciencias de La Salud, Pontificia Universidad Javeriana Seccional Cali, Cali 760021, Colombia;
| | | | - Silverio Garzón
- Departamento de Ciencias Básicas, Facultad de Ciencias de La Salud, Pontificia Universidad Javeriana Seccional Cali, Cali 760021, Colombia;
| | | | - Oscar Daniel Villarreal-Nieto
- Departamento de Alimentación y Nutrición, Facultad de Ciencias de La Salud, Pontificia Universidad Javeriana Seccional Cali, Cali 760021, Colombia;
| |
Collapse
|
4
|
Turner O, Mitchell N, Ruddock A, Purvis A, Ranchordas MK. Fluid Balance, Sodium Losses and Hydration Practices of Elite Squash Players during Training. Nutrients 2023; 15:nu15071749. [PMID: 37049589 PMCID: PMC10096645 DOI: 10.3390/nu15071749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 03/30/2023] [Accepted: 04/01/2023] [Indexed: 04/07/2023] Open
Abstract
Elite squash players are reported to train indoors at high volumes and intensities throughout a microcycle. This may increase hydration demands, with hypohydration potentially impairing many key performance indicators which characterise elite squash performance. Consequently, the main aim of this study was to quantify the sweat rates and sweat [Na+] of elite squash players throughout a training session, alongside their hydration practices. Fourteen (males = seven; females = seven) elite or world class squash player’s fluid balance, sweat [Na+] and hydration practices were calculated throughout a training session in moderate environmental conditions (20 ± 0.4 °C; 40.6 ± 1% RH). Rehydration practices were also quantified post-session until the players’ next training session, with some training the same day and some training the following day. Players had a mean fluid balance of −1.22 ± 1.22% throughout the session. Players had a mean sweat rate of 1.11 ± 0.56 L·h−1, with there being a significant difference between male and female players (p < 0.05), and a mean sweat (Na+) of 46 ± 12 mmol·L−1. Players training the following day were able to replace fluid and sodium losses, whereas players training again on the same day were not. These data suggest the variability in players hydration demands and highlight the need to individualise hydration strategies, as well as training prescription, to ensure players with high hydration demands have ample time to optimally rehydrate.
Collapse
Affiliation(s)
- Ollie Turner
- Academy of Sport & Physical Activity, Sheffield Hallam University, Sheffield S10 2BP, UK
- English Institute of Sport, Manchester M11 3BS, UK
| | | | - Alan Ruddock
- Academy of Sport & Physical Activity, Sheffield Hallam University, Sheffield S10 2BP, UK
| | - Alison Purvis
- Academy of Sport & Physical Activity, Sheffield Hallam University, Sheffield S10 2BP, UK
| | - Mayur K. Ranchordas
- Academy of Sport & Physical Activity, Sheffield Hallam University, Sheffield S10 2BP, UK
| |
Collapse
|
5
|
Klous L, Folkerts M, Daanen H, Gerrett N. The effect of sweat sample storage condition on sweat content. Temperature (Austin) 2021; 8:254-261. [PMID: 34485619 PMCID: PMC8409746 DOI: 10.1080/23328940.2020.1867294] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Due to time and logistical constraints sweat samples cannot always be analyzed immediately. The purpose of this study was to investigate the effect of storage temperature and duration on sweat electrolyte and metabolite concentrations. Twelve participants cycled for 60 min at 40 W.m−2 in 33°C and 65% RH. Using the absorbent patch technique, six sweat samples were collected from the posterior torso. Sweat from the six samples was mixed, divided again over six samples and placed in sealed vials. Sweat sodium, chloride, potassium, ammonia, lactate and urea concentrations in one sample were determined immediately. Two samples were stored at room temperature (~25°C, 42% RH) for 7 and 28 days respectively. The remaining samples were frozen at −20°C for 1 h, 7 or 28 days respectively before analysis. Sweat sodium, chloride, potassium and urea concentrations were not affected by storage temperature and duration. Sweat lactate decreased (−1.8 ± 1.8 mmol.L−1, P = 0.007) and ammonia concentrations increased (5.1 ± 3.9 mmol.L−1, P = 0.017) after storage for 28 days at 25°C only. The storage temperature and duration did not affect sodium, chloride, potassium and urea concentrations. However, sweat samples should not be stored for longer than 7 days at 25°C to obtain reliable sweat lactate and ammonia concentrations. When samples are frozen at −20°C, the storage duration could be extended to 28 days for these components.
Collapse
Affiliation(s)
- Lisa Klous
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Mireille Folkerts
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Hein Daanen
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Nicola Gerrett
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| |
Collapse
|
6
|
Ghaffari R, Yang DS, Kim J, Mansour A, Wright JA, Model JB, Wright DE, Rogers JA, Ray TR. State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics. ACS Sens 2021; 6:2787-2801. [PMID: 34351759 DOI: 10.1021/acssensors.1c01133] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Da Som Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Joohee Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Amer Mansour
- Division of Biological Sciences, The University of Chicago, Chicago, Illinois 60637, United States
| | - John A. Wright
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Jeffrey B. Model
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Donald E. Wright
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - John A. Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
- Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, and Chemistry, Northwestern University, Evanston, Illinois 60202, United States
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois 60611, United States
| | - Tyler R. Ray
- Department of Mechanical Engineering, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96822, United States
- Department of Cell and Molecular Biology, John A. Burns School of Medicine, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96813, United States
| |
Collapse
|
7
|
Klous L, Folkerts M, Daanen H, Gerrett N. The effect of short and continuous absorbent patch application on local skin temperature underneath. Physiol Meas 2021; 42. [PMID: 33784659 DOI: 10.1088/1361-6579/abf364] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 03/30/2021] [Indexed: 11/11/2022]
Abstract
Objective. By attaching absorbent patches to the skin to collect sweat, an increase in local skin temperature (Tsk) underneath the patches seems unavoidable. Yet this effect has not been quantified. The present study investigates the effect of absorbent patch application on localTskunderneath.Approach. Ten healthy participants cycled for 60 min at an exercise intensity relative to their body surface area (40 W.m-2) in three environmental conditions (temperate: 25 °C 45% RH, hot-humid: 33 °C 65% RH and hot-dry: 40 °C 30% RH). The effect of short sweat sampling (i.e. from min 25-30 to min 55-60) onTskwas examined on the right scapula.Tskof the left scapula served as control. The effect of continuous sweat sampling (i.e. four consecutive 15 min periods) onTskwas examined on the right upper arm.Tskof the left upper arm served as control.Main results. Neither short nor continuous application of absorbent sweat patches affectedTskunderneath the patches in the hot-humid and hot-dry condition (P > 0.05). In the temperate condition, continuous application led to a significant increase inTskunderneath the patches during the first and second minute. This increase remained throughout the experiment (1.8 ± 0.6 °C;P < 0.001). Short application of sweat patches did not affect the localTskunderneath (P > 0.05) in the temperate condition.Significance. To avoid a significant increase in localTskunderneath sweat patches, continuous application should be prevented in, especially, a temperate condition. Timely removal of sweat patches should be taken into account during longer periods of collecting sweat in field or laboratories settings.
Collapse
Affiliation(s)
- Lisa Klous
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Mireille Folkerts
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Hein Daanen
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Nicola Gerrett
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| |
Collapse
|
8
|
Physiological mechanisms determining eccrine sweat composition. Eur J Appl Physiol 2020; 120:719-752. [PMID: 32124007 PMCID: PMC7125257 DOI: 10.1007/s00421-020-04323-7] [Citation(s) in RCA: 144] [Impact Index Per Article: 28.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 02/11/2020] [Indexed: 02/08/2023]
Abstract
Purpose The purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status. Methods This narrative review includes the major sweat electrolytes (sodium, chloride, and potassium), other micronutrients (e.g., calcium, magnesium, iron, copper, zinc, vitamins), metabolites (e.g., glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), and other compounds (e.g., cytokines and cortisol). Results Ion membrane transport mechanisms for sodium and chloride are well established, but the mechanisms of secretion and/or reabsorption for most other sweat solutes are still equivocal. Correlations between sweat and blood have not been established for most constituents, with perhaps the exception of ethanol. With respect to sweat diagnostics, it is well accepted that elevated sweat sodium and chloride is a useful screening tool for cystic fibrosis. However, sweat electrolyte concentrations are not predictive of hydration status or sweating rate. Sweat metabolite concentrations are not a reliable biomarker for exercise intensity or other physiological stressors. To date, glucose, cytokine, and cortisol research is too limited to suggest that sweat is a useful surrogate for blood. Conclusion Final sweat composition is not only influenced by extracellular solute concentrations, but also mechanisms of secretion and/or reabsorption, sweat flow rate, byproducts of sweat gland metabolism, skin surface contamination, and sebum secretions, among other factors related to methodology. Future research that accounts for these confounding factors is needed to address the existing gaps in the literature. Electronic supplementary material The online version of this article (10.1007/s00421-020-04323-7) contains supplementary material, which is available to authorized users.
Collapse
|
9
|
Baker LB. Physiology of sweat gland function: The roles of sweating and sweat composition in human health. Temperature (Austin) 2019; 6:211-259. [PMID: 31608304 PMCID: PMC6773238 DOI: 10.1080/23328940.2019.1632145] [Citation(s) in RCA: 315] [Impact Index Per Article: 52.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 06/06/2019] [Accepted: 06/08/2019] [Indexed: 12/21/2022] Open
Abstract
The purpose of this comprehensive review is to: 1) review the physiology of sweat gland function and mechanisms determining the amount and composition of sweat excreted onto the skin surface; 2) provide an overview of the well-established thermoregulatory functions and adaptive responses of the sweat gland; and 3) discuss the state of evidence for potential non-thermoregulatory roles of sweat in the maintenance and/or perturbation of human health. The role of sweating to eliminate waste products and toxicants seems to be minor compared with other avenues of excretion via the kidneys and gastrointestinal tract; as eccrine glands do not adapt to increase excretion rates either via concentrating sweat or increasing overall sweating rate. Studies suggesting a larger role of sweat glands in clearing waste products or toxicants from the body may be an artifact of methodological issues rather than evidence for selective transport. Furthermore, unlike the renal system, it seems that sweat glands do not conserve water loss or concentrate sweat fluid through vasopressin-mediated water reabsorption. Individuals with high NaCl concentrations in sweat (e.g. cystic fibrosis) have an increased risk of NaCl imbalances during prolonged periods of heavy sweating; however, sweat-induced deficiencies appear to be of minimal risk for trace minerals and vitamins. Additional research is needed to elucidate the potential role of eccrine sweating in skin hydration and microbial defense. Finally, the utility of sweat composition as a biomarker for human physiology is currently limited; as more research is needed to determine potential relations between sweat and blood solute concentrations.
Collapse
Affiliation(s)
- Lindsay B. Baker
- Gatorade Sports Science Institute, PepsiCo R&D Physiology and Life Sciences, Barrington, IL, USA
| |
Collapse
|
10
|
Barnes KA, Anderson ML, Stofan JR, Dalrymple KJ, Reimel AJ, Roberts TJ, Randell RK, Ungaro CT, Baker LB. Normative data for sweating rate, sweat sodium concentration, and sweat sodium loss in athletes: An update and analysis by sport. J Sports Sci 2019; 37:2356-2366. [DOI: 10.1080/02640414.2019.1633159] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
11
|
Relf R, Willmott A, Flint MS, Beale L, Maxwell N. Reliability of a wearable sweat rate monitor and routine sweat analysis techniques under heat stress in females. J Therm Biol 2018; 79:209-217. [PMID: 30612681 DOI: 10.1016/j.jtherbio.2018.12.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 12/17/2018] [Accepted: 12/17/2018] [Indexed: 11/17/2022]
Abstract
INTRODUCTION The aim of the study was to evaluate the reliability of five different sweat analysis techniques which measure; whole body sweat rate [WBSR], local sweat rate [LSR] (via technical absorbent [TA] method and KuduSmart® monitor), sweat conductivity [SC] and sweat gland activation [SGA] in a female population when exercising moderately under heat stress. METHODS Fourteen females (age; 26 ± 7 years, body mass; 66.5 ± 7.6 kg, height; 167.1 ± 6.4 cm) completed a preliminary threshold walking test (to determine exercise intensity) and two main trials, separated by 2 days. Main trials consisted of 30-min seated rest in the environmental chamber (35 °C, 50% relative humidity) in an upper body sauna-suit, before its removal, and walking at a moderate intensity (4 metabolic equivalents) for 30-min (speeds ranged from 4.8 to 6.5 km h-1). WBSR was measured via nude mass pre and post exercise. The TA and Tegaderm patches (for sweat sodium chloride) were placed on the back, forearm and chest for the entire 60-min, replicated for all participants for both trials. SGA was assessed following the 60-min trial and the KuduSmart® monitor was placed on the left arm for the 30-min of exercise. RESULTS WBSR, LSR methods and SC demonstrated no difference between trials (p > 0.05), good agreement (within limits), strong correlations (r ≥ 0.88) and low typical error of measurements [TEM] (< 0.04 L min-1, 0.13 mg min-1 cm-2 and 8 mmol L-1, respectively). SGA method showed moderate intra-class correlation (r = 0.80), with high TEM (5 glands) and large limits of agreement. CONCLUSION Sudomotor function is reliable, as demonstrated by good reliability, small TEM and strong correlations. The use of these sweat techniques is appropriate and practical in females who are exercising at moderate intensity under heat stress, and so, may aid future interventions. SGA shows larger variation and should be used with caution.
Collapse
Affiliation(s)
- Rebecca Relf
- Environmental Extremes Laboratory, University of Brighton, Eastbourne BN20 7SR, UK.
| | - Ashley Willmott
- Environmental Extremes Laboratory, University of Brighton, Eastbourne BN20 7SR, UK
| | - Melanie S Flint
- Cancer Stress Laboratory, University of Brighton, Moulsecoomb BN24GJ, UK; Centre for Stress and Age-Related Disease, Brighton, East Sussex, UK
| | - Louisa Beale
- Environmental Extremes Laboratory, University of Brighton, Eastbourne BN20 7SR, UK
| | - Neil Maxwell
- Environmental Extremes Laboratory, University of Brighton, Eastbourne BN20 7SR, UK
| |
Collapse
|
12
|
Ayotte D, Corcoran MP. Individualized hydration plans improve performance outcomes for collegiate athletes engaging in in-season training. J Int Soc Sports Nutr 2018; 15:27. [PMID: 29866199 PMCID: PMC5987390 DOI: 10.1186/s12970-018-0230-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Accepted: 05/17/2018] [Indexed: 11/16/2022] Open
Abstract
Background Athletes commonly consume insufficient fluid and electrolytes just prior to, or during training and competition. Unlike non-athletes or athletes who do not engage in frequent rigorous and prolonged training sessions, “hard trainers” may require additional sodium and better benefit from a hydration plan tailored to their individual physiology. The purpose of this randomized cross-over study was to determine whether a hydration plan based off of an athlete’s sweat rate and sodium loss improves anaerobic and neurocognitive performance during a moderate to hard training session as well as heart rate recovery from this session. Methods Collegiate athletes who were injury free and could exercise at ≥ 75% of their maximum heart rate for a minimum of 45 min were recruited for this randomized, cross-over study. After completing a questionnaire assessing hydration habits, participants were randomized either to a prescription hydration plan (PHP), which considered sweat rate and sodium loss or instructed to follow their normal ad libitum hydration habits (NHP) during training. Attention and awareness, as well as lower body anaerobic power (standing long jump) were assessed immediately before and after a moderate to hard training session of ≥ 45 min. Heart rate recovery was also measured. After a washout period of 7 days, the PHP group repeated the training bout with their normal hydration routine, while the NHP group were provided with a PHP plan and were assessed as previously described. Results Fifteen athletes from three different sports, aged 20 ± 0.85 years, participated in this study. Most participants reported feeling somewhat or very dehydrated after a typical training session. Compared to their NHP, participants following a PHP jumped 4.53 ± 3.80 in. farther, tracked moving objects 0.36 ± 0.60 m/second faster, and exhibited a faster heart rate recovery following a moderate to hard training session of 45–120 min in duration. Conclusion A tailored hydration plan, based on an athlete’s fluid and sodium loss has the potential to improve anaerobic power, attention and awareness, and heart rate recovery time.
Collapse
Affiliation(s)
- David Ayotte
- Department of Health Sciences, Merrimack College, O'Reilly Hall, Room 414, 315 Turnpike Street, North Andover, MA, 01845, USA
| | - Michael P Corcoran
- Department of Health Sciences, Merrimack College, O'Reilly Hall, Room 414, 315 Turnpike Street, North Andover, MA, 01845, USA.
| |
Collapse
|
13
|
Silva D, Moreira R, Sokhatska O, Beltrão M, Montanha T, Garcia-Larsen V, Villegas R, Severo M, Pizarro A, Pinto M, Martins C, Duarte A, Delgado L, Rufo J, Paciência I, Teixeira JP, Costa C, Moreira P, Carvalho J, Moreira A. Meal-exercise challenge and physical activity reduction impact on immunity and inflammation (MERIIT trial). Contemp Clin Trials Commun 2018; 10:177-189. [PMID: 30009276 PMCID: PMC6042468 DOI: 10.1016/j.conctc.2018.05.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 04/13/2018] [Accepted: 05/03/2018] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND The effect of a pre-exercise meal as countermeasure to exercise induced immunodepression is poorly known. Also, sedentary behavior is associated with increased cardiometabolic risk but studies on immune changes are lacking. Therefore, we aimed to assess: 1) the impact of a pre-exercise Mediterranean meal (MdM) compared with a fast-food type meal (FFM) on exercise-induced immunological changes and 2) the impact of an induced acute period of sedentary behavior on neuro-immune-endocrine status. METHODS /Design: This is a two steps clinical trial including: (a) randomized crossover clinical trial, comparing the effect a high-fat/low-nutrient dense meal, FFM, with an isoenergetic similar high-nutrient dense meal, MdM, in the immune response to an exercise challenge (EC) and (b) a pilot trial assessing the neuro-immune-endocrine change induced by acute decreasing by half the usual physical activity level. RESULTS A total of 46 participants (26 females), median aged 25 years were included. Of those 39-completed protocol, including overweight, physical active and inactive and participants with asthma. There were no differences in the EC between interventions. Dietary factors and physical activity were closely monitored during interventions and kept similar. During physical inactivity induction, 31% reached the target of 50% reduction in mean step number and 77% reached a 30% reduction. CONCLUSION The use of a pre-exercise meal to modulate immune response and the understanding of the immunological impact of physical inactivity might help to establish future recommendations on how to practice exercise in a safer way and to recognize the potential impact of inactivity.
Collapse
Affiliation(s)
- Diana Silva
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
- Serviço de Imunoalergologia, Centro Hospitalar São João, EPE, Porto, Portugal
| | - Rita Moreira
- Faculty of Nutrition and Food Sciences University of Porto, Portugal
| | - Oksana Sokhatska
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
| | - Marília Beltrão
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
| | - Tiago Montanha
- Research Centre in Physical Activity, Health and Leisure - Faculty of Sports, Porto, Portugal
| | - Vanessa Garcia-Larsen
- Department of International Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, USA
| | | | - Milton Severo
- EPIUnit – Institute of Public Health, University of Porto, Porto, Portugal
| | - Andreia Pizarro
- Research Centre in Physical Activity, Health and Leisure - Faculty of Sports, Porto, Portugal
| | - Mariana Pinto
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
- Faculty of Nutrition and Food Sciences University of Porto, Portugal
| | - Carla Martins
- Serviço de Imunoalergologia, Centro Hospitalar São João, EPE, Porto, Portugal
| | - Ana Duarte
- Department of Environmental Health, Portuguese National Institute of Health, Portugal
| | - Luís Delgado
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
- Serviço de Imunoalergologia, Centro Hospitalar São João, EPE, Porto, Portugal
| | - João Rufo
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
- EPIUnit – Institute of Public Health, University of Porto, Porto, Portugal
| | - Inês Paciência
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
- EPIUnit – Institute of Public Health, University of Porto, Porto, Portugal
| | - João Paulo Teixeira
- Department of Environmental Health, Portuguese National Institute of Health, Portugal
| | - Carla Costa
- Department of Environmental Health, Portuguese National Institute of Health, Portugal
| | - Pedro Moreira
- Faculty of Nutrition and Food Sciences University of Porto, Portugal
| | - Joana Carvalho
- Research Centre in Physical Activity, Health and Leisure - Faculty of Sports, Porto, Portugal
| | - André Moreira
- Basic and Clinical Immunology, Department of Pathology, Faculty of Medicine, University of Porto, Portugal
- Serviço de Imunoalergologia, Centro Hospitalar São João, EPE, Porto, Portugal
- EPIUnit – Institute of Public Health, University of Porto, Porto, Portugal
| |
Collapse
|
14
|
Sweat Sodium, Potassium, and Chloride Concentrations Analyzed Same Day as Collection Versus After 7 Days Storage in a Range of Temperatures. Int J Sport Nutr Exerc Metab 2018; 28:238-245. [PMID: 29140143 DOI: 10.1123/ijsnem.2017-0199] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The purpose of this study was to determine the effect of storage temperature on sodium ([Na+]), potassium ([K+]), and chloride ([Cl-]) concentrations of sweat samples analyzed 7 days after collection. Using the absorbent patch technique, 845 sweat samples were collected from 39 subjects (32 ± 7 years, 72.9 ± 10.5 kg) during exercise. On the same day as collection (PRESTORAGE), 609 samples were analyzed for [Na+], [Cl-], and [K+] by ion chromatography (IC) and 236 samples were analyzed for [Na+] using a compact ion-selective electrode (ISE). Samples were stored at one of the four conditions: -20 °C (IC, n = 138; ISE, n = 60), 8 °C (IC, n = 144; ISE, n = 59), 23 °C (IC, n = 159; ISE, n = 59), or alternating between 8 °C and 23 °C (IC, n = 168; ISE, n = 58). After 7 days in storage (POSTSTORAGE), samples were reanalyzed using the same technique as PRESTORAGE. PRESTORAGE sweat electrolyte concentrations were highly related to that of POSTSTORAGE (intraclass correlation coefficient: .945-.989, p < .001). Mean differences (95% confidence intervals) between PRESTORAGE and POSTSTORAGE were statistically, but not practically, significant for most comparisons: IC [Na+]: -0.5(0.9) to -2.1(0.9) mmol/L; IC [K+]: -0.1(0.1) to -0.2(0.1) mmol/L; IC [Cl-]: -0.4(1.4) to -1.3(1.3) mmol/L; ISE [Na+]: -2.0(1.1) to 1.3(1.1) mmol/L. Based on typical error of measurement results, 95% of the time PRESTORAGE and POSTSTORAGE sweat [Na+], [K+], and [Cl-] by IC analysis fell within ±7-9, ±0.6-0.7, and ±9-13 mmol/L, respectively, while sweat [Na+] by ISE was ±6 mmol/L. All conditions produced high reliability and acceptable levels of agreement in electrolyte concentrations of sweat samples analyzed on the day of collection versus after 7 days in storage.
Collapse
|
15
|
Ranchordas MK, Tiller NB, Ramchandani G, Jutley R, Blow A, Tye J, Drury B. Normative data on regional sweat-sodium concentrations of professional male team-sport athletes. J Int Soc Sports Nutr 2017; 14:40. [PMID: 29093646 PMCID: PMC5661918 DOI: 10.1186/s12970-017-0197-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 10/22/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The purpose of this paper was to report normative data on regional sweat sweat-sodium concentrations of various professional male team-sport athletes, and to compare sweat-sodium concentrations among sports. Data to this effect would inform our understanding of athlete sodium requirements, thus allowing for the individualisation of sodium replacement strategies. Accordingly, data from 696 athletes (Soccer, n = 270; Rugby, n = 181; Baseball, n = 133; American Football, n = 60; Basketball, n = 52) were compiled for a retrospective analysis. Regional sweat-sodium concentrations were collected using the pilocarpine iontophoresis method, and compared to self-reported measures collected via questionnaire. RESULTS Sweat-sodium concentrations were significantly higher (p < 0.05) in American football (50.4 ± 15.3 mmol·L-1), baseball (54.0 ± 14.0 mmol·L-1), and basketball (48.3 ± 14.0 mmol·L-1) than either soccer (43.2 ± 12.0 mmol·L-1) or rugby (44.0 ± 12.1 mmol·L-1), but with no differences among the N.American or British sports. There were strong positive correlations between sweat-sodium concentrations and self-reported sodium losses in American football (rs = 0.962, p < 0.001), basketball (rs = 0.953, p < 0.001), rugby (rs = 0.813, p < 0.001), and soccer (rs = 0.748, p < 0.001). CONCLUSIONS The normative data provided on sweat-sodium concentrations might assist sports science/medicine practitioners in generating bespoke hydration and electrolyte-replacement strategies to meet the sodium demands of professional team-sport athletes. Moreover, these novel data suggest that self-reported measures of sodium loss might serve as an effective surrogate in the absence of direct measures; i.e., those which are more expensive or non-readily available.
Collapse
Affiliation(s)
- Mayur K. Ranchordas
- Academy of Sport and Physical Acitivty, Sheffield Hallam University, Sheffield, S10 2BP UK
| | - Nicholas B. Tiller
- Academy of Sport and Physical Acitivty, Sheffield Hallam University, Sheffield, S10 2BP UK
| | - Girish Ramchandani
- Sport Industry Research Centre, Sheffield Hallam University, Sheffield, S10 2BP UK
| | - Raj Jutley
- Precision Hydration, 43 Saffron Drive, Christchurch, BH23 4LR UK
| | - Andrew Blow
- Precision Hydration, 43 Saffron Drive, Christchurch, BH23 4LR UK
| | - Jonny Tye
- Precision Hydration, 43 Saffron Drive, Christchurch, BH23 4LR UK
| | - Ben Drury
- Hartpury University Centre, Hartpury, Gloucester, GL19 3BE UK
| |
Collapse
|
16
|
Gao W, Brooks GA, Klonoff DC. Wearable physiological systems and technologies for metabolic monitoring. J Appl Physiol (1985) 2017; 124:548-556. [PMID: 28970200 DOI: 10.1152/japplphysiol.00407.2017] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Wearable sensors allow continuous monitoring of metabolites for diabetes, sports medicine, exercise science, and physiology research. These sensors can continuously detect target analytes in skin interstitial fluid (ISF), tears, saliva, and sweat. In this review, we will summarize developments on wearable devices and their potential applications in research, clinical practice, and recreational and sporting activities. Sampling skin ISF can require insertion of a needle into the skin, whereas sweat, tears, and saliva can be sampled by devices worn outside the body. The most widely sampled metabolite from a wearable device is glucose in skin ISF for monitoring diabetes patients. Continuous ISF glucose monitoring allows estimation of the glucose concentration in blood without the pain, inconvenience, and blood waste of fingerstick capillary blood glucose testing. This tool is currently used by diabetes patients to provide information for dosing insulin and determining a diet and exercise plan. Similar technologies for measuring concentrations of other analytes in skin ISF could be used to monitor athletes, emergency responders, warfighters, and others in states of extreme physiological stress. Sweat is a potentially useful substrate for sampling analytes for metabolic monitoring during exercise. Lactate, sodium, potassium, and hydrogen ions can be measured in sweat. Tools for converting the concentrations of these analytes sampled from sweat, tears, and saliva into blood concentrations are being developed. As an understanding of the relationships between the concentrations of analytes in blood and easily sampled body fluid increases, then the benefits of new wearable devices for metabolic monitoring will also increase.
Collapse
Affiliation(s)
- Wei Gao
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, Berkeley, California.,Department of Medical Engineering, California Institute of Technology , Pasadena, California
| | - George A Brooks
- Department of Integrative Biology, University of California Berkeley, Berkeley, Berkeley, California
| | - David C Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center , San Mateo, California
| |
Collapse
|