1
|
Chen Y, Fernandez Z, Scheel N, Gifani M, Zhu DC, Counts SE, Dorrance AM, Razansky D, Yu X, Qian W, Qian C. Novel inductively coupled ear-bars (ICEs) to enhance restored fMRI signal from susceptibility compensation in rats. Cereb Cortex 2024; 34:bhad479. [PMID: 38100332 PMCID: PMC10793587 DOI: 10.1093/cercor/bhad479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/20/2023] [Accepted: 11/21/2023] [Indexed: 12/17/2023] Open
Abstract
Functional magnetic resonance imaging faces inherent challenges when applied to deep-brain areas in rodents, e.g. entorhinal cortex, due to the signal loss near the ear cavities induced by susceptibility artifacts and reduced sensitivity induced by the long distance from the surface array coil. Given the pivotal roles of deep brain regions in various diseases, optimized imaging techniques are needed. To mitigate susceptibility-induced signal losses, we introduced baby cream into the middle ear. To enhance the detection sensitivity of deep brain regions, we implemented inductively coupled ear-bars, resulting in approximately a 2-fold increase in sensitivity in entorhinal cortex. Notably, the inductively coupled ear-bar can be seamlessly integrated as an add-on device, without necessitating modifications to the scanner interface. To underscore the versatility of inductively coupled ear-bars, we conducted echo-planner imaging-based task functional magnetic resonance imaging in rats modeling Alzheimer's disease. As a proof of concept, we also demonstrated resting-state-functional magnetic resonance imaging connectivity maps originating from the left entorhinal cortex-a central hub for memory and navigation networks-to amygdala hippocampal area, Insular Cortex, Prelimbic Systems, Cingulate Cortex, Secondary Visual Cortex, and Motor Cortex. This work demonstrates an optimized procedure for acquiring large-scale networks emanating from a previously challenging seed region by conventional magnetic resonance imaging detectors, thereby facilitating improved observation of functional magnetic resonance imaging outcomes.
Collapse
Affiliation(s)
- Yi Chen
- Department of High-field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tuebingen 72076, Germany
- Department of Radiology and Cognitive Imaging Research Center, Michigan State University, East Lansing, MI 48824, United States
| | - Zachary Fernandez
- Department of Radiology and Cognitive Imaging Research Center, Michigan State University, East Lansing, MI 48824, United States
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, United States
| | - Norman Scheel
- Department of Radiology and Cognitive Imaging Research Center, Michigan State University, East Lansing, MI 48824, United States
| | - Mahsa Gifani
- Department of Translational Neuroscience, Michigan State University, Grand Rapids, MI 49503, United States
| | - David C Zhu
- Department of Radiology and Cognitive Imaging Research Center, Michigan State University, East Lansing, MI 48824, United States
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, United States
| | - Scott E Counts
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, United States
- Department of Translational Neuroscience, Michigan State University, Grand Rapids, MI 49503, United States
- Department of Family Medicine, Michigan State University, Grand Rapids, MI 49503, United States
- Department of Hauenstein Neurosciences Center, Mercy Health Saint Mary’s Hospital, Grand Rapids, MI 49508, United States
- Michigan Alzheimer’s Disease Research Center, Ann Arbor, MI 48105, United States
| | - Anne M Dorrance
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, United States
- Department of Pharmacology and Toxicology, Michigan State University, East Lansing, MI 48824, United States
| | - Daniel Razansky
- Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich 8006, Switzerland
- Department of Information Technology and Electrical Engineering, ETH Zurich, Institute for Biomedical Engineering, , Zurich 8092, Switzerland
- Zurich Neuroscience Center, Zurich 8057, Switzerland
| | - Xin Yu
- Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02114, United States
| | - Wei Qian
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, United States
| | - Chunqi Qian
- Department of Radiology and Cognitive Imaging Research Center, Michigan State University, East Lansing, MI 48824, United States
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, United States
| |
Collapse
|
2
|
Liu X, Hike D, Choi S, Man W, Ran C, Zhou XA, Jiang Y, Yu X. Mapping the bioimaging marker of Alzheimer's disease based on pupillary light response-driven brain-wide fMRI in awake mice. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.12.20.572613. [PMID: 38187675 PMCID: PMC10769340 DOI: 10.1101/2023.12.20.572613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
Abstract
Pupil dynamics has emerged as a critical non-invasive indicator of brain state changes. In particular, pupillary-light-responses (PLR) in Alzheimer's disease (AD) patients may be used as biomarkers of brain degeneration. To characterize AD-specific PLR and its underlying neuromodulatory sources, we combined high-resolution awake mouse fMRI with real-time pupillometry to map brain-wide event-related correlation patterns based on illumination-driven pupil constriction ( P c ) and post-illumination pupil dilation recovery (amplitude, P d , and time, T ). The P c -driven differential analysis revealed altered visual signal processing coupled with reduced thalamocortical activation in AD mice compared with the wild-type normal mice. In contrast, the post-illumination pupil dilation recovery-based fMRI highlighted multiple brain areas related to AD brain degeneration, including the cingulate cortex, hippocampus, septal area of the basal forebrain, medial raphe nucleus, and pontine reticular nuclei (PRN). Also, brain-wide functional connectivity analysis highlighted the most significant changes in PRN of AD mice, which serves as the major subcortical relay nuclei underlying oculomotor function. This work combined non-invasive pupil-fMRI measurements in preclinical models to identify pupillary biomarkers based on neuromodulatory dysfunction coupled with AD brain degeneration.
Collapse
|
3
|
Choi S, Chen Y, Zeng H, Biswal B, Yu X. Identifying the distinct spectral dynamics of laminar-specific interhemispheric connectivity with bilateral line-scanning fMRI. J Cereb Blood Flow Metab 2023; 43:1115-1129. [PMID: 36803280 PMCID: PMC10291453 DOI: 10.1177/0271678x231158434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 11/30/2022] [Accepted: 12/12/2022] [Indexed: 02/23/2023]
Abstract
Despite extensive efforts to identify interhemispheric functional connectivity (FC) with resting-state (rs-) fMRI, correlated low-frequency rs-fMRI signal fluctuation across homotopic cortices originates from multiple sources. It remains challenging to differentiate circuit-specific FC from global regulation. Here, we developed a bilateral line-scanning fMRI method to detect laminar-specific rs-fMRI signals from homologous forepaw somatosensory cortices with high spatial and temporal resolution in rat brains. Based on spectral coherence analysis, two distinct bilateral fluctuation spectral features were identified: ultra-slow fluctuation (<0.04 Hz) across all cortical laminae versus Layer (L) 2/3-specific evoked BOLD at 0.05 Hz based on 4 s on/16 s off block design and resting-state fluctuations at 0.08-0.1 Hz. Based on the measurements of evoked BOLD signal at corpus callosum (CC), this L2/3-specific 0.05 Hz signal is likely associated with neuronal circuit-specific activity driven by the callosal projection, which dampened ultra-slow oscillation less than 0.04 Hz. Also, the rs-fMRI power variability clustering analysis showed that the appearance of L2/3-specific 0.08-0.1 Hz signal fluctuation is independent of the ultra-slow oscillation across different trials. Thus, distinct laminar-specific bilateral FC patterns at different frequency ranges can be identified by the bilateral line-scanning fMRI method.
Collapse
Affiliation(s)
- Sangcheon Choi
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charlestown, MA, USA
- Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Yi Chen
- Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Hang Zeng
- Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen, Germany
| | - Bharat Biswal
- Department of Biomedical Engineering, NJIT, Newark, NJ, USA
| | - Xin Yu
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charlestown, MA, USA
| |
Collapse
|
4
|
Ming X, Cheng X, Tian C, Li W, Wang R, Qian C, Zeng X. Evaluation of condylar osseous changes using a wireless detector with proton density-weighted imaging sequences. Quant Imaging Med Surg 2023; 13:17-26. [PMID: 36620157 PMCID: PMC9816719 DOI: 10.21037/qims-22-424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 09/27/2022] [Indexed: 11/30/2022]
Abstract
Background Cone-beam computed tomography (CBCT) is the gold standard for evaluating condylar osseous changes. However, the radiation risk and low soft-tissue resolution of CBCT make it unsuitable for evaluating soft tissue such as the articular disc and lateral pterygoid muscle. This study aimed to qualitatively and quantitatively evaluate the feasibility and advantages of using wireless detectors (WD) with proton density-weighted imaging (PDWI) sequences to image condyle changes in patients with temporomandibular disorders (TMD). Methods This study involved 20 patients (male =8, female =12; mean age 31.65 years, SD 12.68 years) with TMD. All participants underwent a closed oblique sagittal PDWI scan with head/neck coupling coiling (HNCC) and wireless detector-HNCC (WD-HNCC) on a 3.0 T magnetic resonance imaging (MRI) scanner. Subsequently, the changes in the condyle bones in the scanned images for the 2 image types were scored subjectively and compared qualitatively. The contrast-to-noise ratio (CNR) of the 2 types of scanned images was compared quantitatively. The comparison of CNR differences between the 2 types of images was performed using the paired t-test. The kappa statistic was used to test the consistency of quantitative analyses of MRI images between observers. The subjective scores of condylar osseous changes in the 2 types of images were compared by paired rank-sum test. A P value <0.05 was considered statistically significant. Results A total of 40 condyles from 20 patients were scanned. Among them, 8 condyles showed no bone changes, and the other 32 condyles demonstrated condylar osseous changes of varying degrees and nature. These 32 condyles were used in the subsequent analysis. As compared to images acquired by HNCC in the PDWI sequence, the WD-HNCC images more clearly showed mandibular osteophyte, bone cortical erosion, subcortical cystic focus, and bone cortical hyperplasia and thickening. In addition, the WD-HNCC was demonstrated to improve image CNR by 158.9% compared to HNCC (28.17±16.01 vs. 10.88±6.53; t=8.63; P=0.001). Conclusions WD-HNCC in PDWI sequences is suitable for imaging the condylar bone changes of patients with TMD and significantly improves the image quality.
Collapse
Affiliation(s)
- Xing Ming
- Department of Radiology, Guizhou Provincial People’s Hospital, Key Laboratory of Intelligent Medical Imaging Analysis and Accurate Diagnosis of Guizhou Province, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, Guiyang, China
| | - Xinge Cheng
- Department of Radiology, Guizhou Provincial People’s Hospital, Key Laboratory of Intelligent Medical Imaging Analysis and Accurate Diagnosis of Guizhou Province, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, Guiyang, China
| | - Chong Tian
- Department of Radiology, Guizhou Provincial People’s Hospital, Key Laboratory of Intelligent Medical Imaging Analysis and Accurate Diagnosis of Guizhou Province, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, Guiyang, China
| | - Wuchao Li
- Department of Radiology, Guizhou Provincial People’s Hospital, Key Laboratory of Intelligent Medical Imaging Analysis and Accurate Diagnosis of Guizhou Province, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, Guiyang, China
| | - Rongpin Wang
- Department of Radiology, Guizhou Provincial People’s Hospital, Key Laboratory of Intelligent Medical Imaging Analysis and Accurate Diagnosis of Guizhou Province, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, Guiyang, China
| | - Chunqi Qian
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA;,Department of Radiology, Michigan State University, East Lansing, MI, USA
| | - Xianchun Zeng
- Department of Radiology, Guizhou Provincial People’s Hospital, Key Laboratory of Intelligent Medical Imaging Analysis and Accurate Diagnosis of Guizhou Province, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, Guiyang, China
| |
Collapse
|
5
|
Baldelomar EJ, Charlton JR, Bennett KM. Mapping single-nephron filtration in the isolated, perfused rat kidney using magnetic resonance imaging. Am J Physiol Renal Physiol 2022; 323:F602-F611. [PMID: 36049066 PMCID: PMC9602809 DOI: 10.1152/ajprenal.00103.2022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 08/16/2022] [Accepted: 08/25/2022] [Indexed: 12/14/2022] Open
Abstract
The kidney has an extraordinary ability to maintain glomerular filtration despite natural fluctuations in blood pressure and nephron loss. This is partly due to local coordination between single-nephron filtration and vascular perfusion. An improved understanding of the three-dimensional (3-D) functional coordination between nephrons and the vasculature may provide a new perspective of the heterogeneity of kidney function and could inform targeted therapies and timed interventions to slow or prevent the progression of kidney disease. Here, we developed magnetic resonance imaging (MRI) tools to visualize single-nephron function in 3-D throughout the isolated perfused rat kidney. We used an intravenous slow perfusion of a glomerulus-targeted imaging tracer [cationized ferritin (CF)] to map macromolecular dynamics and to identify glomeruli in 3-D, followed by a bolus of a freely filtered tracer (gadolinium diethylenetriamine penta-acetic acid) to map filtration kinetics. There was a wide intrakidney distribution of CF binding rates and estimated single-nephron glomerular filtration rate (eSNGFR) between nephrons. eSNGFR and CF uptake rates did not vary significantly by distance from the kidney surface. eSNGFR varied from ∼10 to ∼100 nL/min throughout the kidney. Whole single-kidney GFR was similar across all kidneys, despite differences in the distributions eSNGFR of and glomerular number, indicating a robust adaptive regulation of individual nephrons to maintain constant single-kidney GFR in the presence of a natural variation in nephron number. This work provides a framework for future studies of single-nephron function in the whole isolated perfused kidney and experiments of single-nephron function in vivo using MRI.NEW & NOTEWORTHY We report MRI tools to measure and map single-nephron function in the isolated, perfused rat kidney. We used imaging tracers to identify nephrons throughout the kidney and to measure the delivery and filtration of the tracers at the location of the glomeruli. With this technique, we directly measured physiological parameters including estimated single-nephron glomerular filtration rate throughout the kidney. This work provides a foundation for new studies to simultaneously map the function of large numbers of nephrons.
Collapse
Affiliation(s)
- Edwin J Baldelomar
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, Missouri
| | - Jennifer R Charlton
- Division of Nephrology, Department of Pediatrics, University of Virginia, Charlottesville, Virginia
| | - Kevin M Bennett
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, Missouri
| |
Collapse
|
6
|
Advancements in nanomedicines for the detection and treatment of diabetic kidney disease. BIOMATERIALS AND BIOSYSTEMS 2022; 6:100047. [PMID: 36824160 PMCID: PMC9934479 DOI: 10.1016/j.bbiosy.2022.100047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/22/2022] [Accepted: 03/27/2022] [Indexed: 12/18/2022] Open
Abstract
In the diabetic kidneys, morbidities such as accelerated ageing, hypertension and hyperglycaemia create a pro-inflammatory microenvironment characterised by extensive fibrogenesis. Radiological techniques are not yet optimised generating inconsistent and non-reproducible data. The gold standard procedure to assess renal fibrosis is kidney biopsy, followed by histopathological assessment. However, this method is risky, invasive, subjective and examines less than 0.01% of kidney tissue resulting in diagnostic errors. As such, less than 10% of patients undergo kidney biopsy, limiting the accuracy of the current diabetic kidney disease (DKD) staging method. Standard treatments suppress the renin-angiotensin system to control hypertension and use of pharmaceuticals aimed at controlling diabetes have shown promise but can cause hypoglycaemia, diuresis and malnutrition as a result of low caloric intake. New approaches to both diagnosis and treatment are required. Nanoparticles (NPs) are an attractive candidate for managing DKD due to their ability to act as theranostic tools that can carry drugs and enhance image contrast. NP-based point-of-care systems can provide physiological information previously considered unattainable and provide control over the rate and location of drug release. Here we discuss the use of nanotechnology in renal disease, its application to both the treatment and diagnosis of DKD. Finally, we propose a new method of NP-based DKD classification that overcomes the current systems limitations.
Collapse
|
7
|
Choi S, Zeng H, Chen Y, Sobczak F, Qian C, Yu X. Laminar-specific functional connectivity mapping with multi-slice line-scanning fMRI. Cereb Cortex 2022; 32:4492-4501. [PMID: 35107125 PMCID: PMC9574235 DOI: 10.1093/cercor/bhab497] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 11/30/2021] [Accepted: 12/01/2021] [Indexed: 11/13/2022] Open
Abstract
Despite extensive studies detecting laminar functional magnetic resonance imaging (fMRI) signals to illustrate the canonical microcircuit, the spatiotemporal characteristics of laminar-specific information flow across cortical regions remain to be fully investigated in both evoked and resting conditions at different brain states. Here, we developed a multislice line-scanning fMRI (MS-LS) method to detect laminar fMRI signals in adjacent cortical regions with high spatial (50 μm) and temporal resolution (100 ms) in anesthetized rats. Across different trials, we detected either laminar-specific positive or negative blood-oxygen-level-dependent (BOLD) responses in the surrounding cortical region adjacent to the most activated cortex under the evoked condition. Specifically, in contrast to typical Layer (L) 4 correlation across different regions due to the thalamocortical projections for trials with positive BOLD, a strong correlation pattern specific in L2/3 was detected for trials with negative BOLD in adjacent regions, which indicated brain state-dependent laminar-fMRI responses based on corticocortical interaction. Also, in resting-state (rs-) fMRI study, robust lag time differences in L2/3, 4, and 5 across multiple cortices represented the low-frequency rs-fMRI signal propagation from caudal to rostral slices. In summary, our study provided a unique laminar fMRI mapping scheme to better characterize trial-specific intra- and inter-laminar functional connectivity in evoked and resting-state MS-LS.
Collapse
Affiliation(s)
- Sangcheon Choi
- Department of High-field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen 72076, Germany,Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen 72074, Germany
| | - Hang Zeng
- Department of High-field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen 72076, Germany,Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen 72074, Germany
| | - Yi Chen
- Department of High-field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen 72076, Germany
| | - Filip Sobczak
- Department of High-field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen 72076, Germany,Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen 72074, Germany
| | - Chunqi Qian
- Address correspondence to Dr Xin Yu, 149, 13th Street, Charlestown, MA 02129, USA. ; Dr Chunqi Qian, 846 Service Rd, East Lansing, MI 48824, USA.
| | - Xin Yu
- Address correspondence to Dr Xin Yu, 149, 13th Street, Charlestown, MA 02129, USA. ; Dr Chunqi Qian, 846 Service Rd, East Lansing, MI 48824, USA.
| |
Collapse
|
8
|
Chen Y, Wang Q, Choi S, Zeng H, Takahashi K, Qian C, Yu X. Focal fMRI signal enhancement with implantable inductively coupled detectors. Neuroimage 2021; 247:118793. [PMID: 34896291 PMCID: PMC8842502 DOI: 10.1016/j.neuroimage.2021.118793] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 12/02/2021] [Accepted: 12/07/2021] [Indexed: 12/16/2022] Open
Abstract
Despite extensive efforts to increase the signal-to-noise ratio (SNR) of fMRI images for brain-wide mapping, technical advances of focal brain signal enhancement are lacking, in particular, for animal brain imaging. Emerging studies have combined fMRI with fiber optic-based optogenetics to decipher circuit-specific neuromodulation from meso to macroscales. High-resolution fMRI is needed to integrate hemodynamic responses into cross-scale functional dynamics, but the SNR remains a limiting factor given the complex implantation setup of animal brains. Here, we developed a multimodal fMRI imaging platform with an implanted inductive coil detector. This detector boosts the tSNR of MRI images, showing a 2–3-fold sensitivity gain over conventional coil configuration. In contrast to the cryoprobe or array coils with limited spaces for implanted brain interface, this setup offers a unique advantage to study brain circuit connectivity with optogenetic stimulation and can be further extended to other multimodal fMRI mapping schemes.
Collapse
Affiliation(s)
- Yi Chen
- Max Planck Institute for Biological Cybernetics, 72076 Tuebingen, Germany; Max Planck Institute for the Science of Light, 91058, Erlangen, Germany
| | - Qi Wang
- Max Planck Institute for Biological Cybernetics, 72076 Tuebingen, Germany; Graduate Training Centre of Neuroscience, University of Tuebingen, 72076 Tuebingen, Germany
| | - Sangcheon Choi
- Max Planck Institute for Biological Cybernetics, 72076 Tuebingen, Germany; Graduate Training Centre of Neuroscience, University of Tuebingen, 72076 Tuebingen, Germany
| | - Hang Zeng
- Max Planck Institute for Biological Cybernetics, 72076 Tuebingen, Germany; Graduate Training Centre of Neuroscience, University of Tuebingen, 72076 Tuebingen, Germany
| | - Kengo Takahashi
- Max Planck Institute for Biological Cybernetics, 72076 Tuebingen, Germany; Graduate Training Centre of Neuroscience, University of Tuebingen, 72076 Tuebingen, Germany
| | - Chunqi Qian
- Department of Radiology, Michigan State University, East Lansing, MI 48824, USA.
| | - Xin Yu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA.
| |
Collapse
|
9
|
Charlton JR, Baldelomar EJ, Hyatt DM, Bennett KM. Nephron number and its determinants: a 2020 update. Pediatr Nephrol 2021; 36:797-807. [PMID: 32350665 PMCID: PMC7606355 DOI: 10.1007/s00467-020-04534-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 02/29/2020] [Accepted: 03/05/2020] [Indexed: 12/30/2022]
Abstract
Studies of human nephron number have been conducted for well over a century and have uncovered a large variability in nephron number. However, the mechanisms influencing nephron endowment and loss, along with the etiology for the wide range among individuals are largely unknown. Advances in imaging technology have allowed investigators to revisit the principles of renal structure and physiology and their roles in the progression of kidney disease. Here, we will review the latest data on the influences impacting nephron number, innovations made over the last 6 years to understand and integrate renal structure and function, and new developments in the tools used to count nephrons in vivo.
Collapse
Affiliation(s)
- Jennifer R. Charlton
- University of Virginia School of Medicine, Department of Pediatrics, Division of Nephrology, Charlottesville, VA, USA
| | - Edwin J. Baldelomar
- Washington University in St. Louis, Department of Radiology, St. Louis, MO, USA
| | - Dylan M. Hyatt
- University of Virginia, School of Medicine, Charlottesville, VA, USA
| | - Kevin M. Bennett
- Washington University in St. Louis, Department of Radiology, St. Louis, MO, USA
| |
Collapse
|
10
|
Bennett KM, Baldelomar EJ, Morozov D, Chevalier RL, Charlton JR. New imaging tools to measure nephron number in vivo: opportunities for developmental nephrology. J Dev Orig Health Dis 2021; 12:179-183. [PMID: 31983353 PMCID: PMC8765346 DOI: 10.1017/s204017442000001x] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The mammalian kidney is a complex organ, requiring the concerted function of up to millions of nephrons. The number of nephrons is constant after nephrogenesis during development, and nephron loss over a life span can lead to susceptibility to acute or chronic kidney disease. New technologies are under development to count individual nephrons in the kidney in vivo. This review outlines these technologies and highlights their relevance to studies of human renal development and disease.
Collapse
Affiliation(s)
- K M Bennett
- Department of Radiology, Washington University, Saint Louis, MO, USA
| | - E J Baldelomar
- Department of Radiology, Washington University, Saint Louis, MO, USA
| | - D Morozov
- Department of Radiology, Washington University, Saint Louis, MO, USA
| | - R L Chevalier
- Department of Pediatrics, University of Virginia, Charlottesville, VA, USA
| | - J R Charlton
- Department of Pediatrics, University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
11
|
DeFreitas MJ, Katsoufis CP, Infante JC, Granda ML, Abitbol CL, Fornoni A. The old becomes new: advances in imaging techniques to assess nephron mass in children. Pediatr Nephrol 2021; 36:517-525. [PMID: 31953750 DOI: 10.1007/s00467-020-04477-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 12/09/2019] [Accepted: 01/08/2020] [Indexed: 12/19/2022]
Abstract
Renal imaging is widely used in the assessment of surrogate markers of nephron mass correlated to renal function. Autopsy studies have tested the validity of various imaging modalities in accurately estimating "true" nephron mass. However, in vivo assessment of nephron mass has been largely limited to kidney volume determination by ultrasonography (US) in pediatric populations. Practical limitations and risks create challenges in incorporating more precise 3D volumetric imaging, like magnetic resonance imaging (MRI), and computed tomography (CT) technologies, compared to US for routine kidney volume assessment in children. Additionally, accounting for structural anomalies such as hydronephrosis when estimating renal parenchymal area in congenital anomalies of the kidney and urinary tract (CAKUT) is important, as it correlates with chronic kidney disease (CKD) progression. 3D imaging using CT and MRI has been shown to be superior to US, which has traditionally relied on 2D measurements to estimate kidney volume using the ellipsoid calculation. Recent innovations using 3D and contrast-enhanced US (CEUS) provide improved accuracy with low risk. Indexing kidney volume to body surface area in children is an important standard that may allow early detection of CKD progression in high-risk populations. This review highlights current understanding of various imaging modalities in assessing nephron mass, discusses applications and limitations, and describes recent advances in the field of imaging and kidney disease. Although renal imaging has been a long-standing, essential tool in assessing kidney disease, innovation and new applications of established technologies provide important tools in the study and management of kidney disease in children.
Collapse
Affiliation(s)
- Marissa J DeFreitas
- Division of Pediatric Nephrology, University of Miami Miller School of Medicine, P.O. Box 016960 (M714), Miami, FL, 33130, USA.
| | - Chryso P Katsoufis
- Division of Pediatric Nephrology, University of Miami Miller School of Medicine, P.O. Box 016960 (M714), Miami, FL, 33130, USA
| | - Juan C Infante
- Section of Pediatric Radiology, Department of Diagnostic Radiology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Michael L Granda
- Division of General Internal Medicine, Department of Medicine, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Carolyn L Abitbol
- Division of Pediatric Nephrology, University of Miami Miller School of Medicine, P.O. Box 016960 (M714), Miami, FL, 33130, USA
| | - Alessia Fornoni
- Katz Family Division of Nephrology and Hypertension, Department of Medicine, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
12
|
Parvin N, Charlton JR, Baldelomar EJ, Derakhshan JJ, Bennett KM. Mapping vascular and glomerular pathology in a rabbit model of neonatal acute kidney injury using MRI. Anat Rec (Hoboken) 2020; 303:2716-2728. [PMID: 32445514 PMCID: PMC7680718 DOI: 10.1002/ar.24419] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 01/30/2020] [Accepted: 03/03/2020] [Indexed: 12/27/2022]
Abstract
Acute kidney injury (AKI) in premature neonates is common due to the administration of life-saving therapies. The impact of AKI on renal morphology and susceptibility to further renal damage is poorly understood. Recent advances in radiological imaging have allowed integration of soft tissue morphology in the intact organ, facilitating a more complete understanding of changes in tissue microstructure associated with pathology. Here, we applied magnetic resonance imaging (MRI) to detect both glomerular and vascular changes in a rabbit model of neonatal AKI, induced by indomethacin and gentamicin. Using combined spin-echo MRI and cationic ferritin enhanced gradient-echo MRI (CFE-MRI), we observed (a) an increased cortical arterial diameter in the AKI cohort compared to healthy controls, and (b) focal loss of vascular density and glomerular loss in a circumferential band ~1 mm from the cortical surface. This combined use of vascular and glomerular imaging may give insight into the etiology of AKI and its impact on renal health later in life.
Collapse
Affiliation(s)
- Neda Parvin
- Department of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Jennifer R Charlton
- University of Virginia Children's Hospital, Department of Pediatrics, Charlottesville, Virginia, USA
| | - Edwin J Baldelomar
- Department of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Jamal J Derakhshan
- Department of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Kevin M Bennett
- Department of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| |
Collapse
|
13
|
Qian W, Yu X, Qian C. Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2020; 8:136594-136604. [PMID: 33747678 PMCID: PMC7971173 DOI: 10.1109/access.2020.3011905] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Wirelessly Amplified NMR Detectors (WAND) can utilize wireless pumping power to amplify MRI signals in situ for sensitivity enhancement of deep-lying tissues that are difficult to access by conventional surface coils. To reconfigure between selective and simultaneous activation in a multielement array, each WAND has a dipole resonance mode for MR signal acquisition and two butterfly modes that support counter-rotating current circulation. Because detectors in the same row share the same lower butterfly frequency but different higher butterfly frequency, a pumping signal at the sum frequency of the dipole mode and the higher butterfly mode can selectively activate individual resonators, leading to 4-fold sensitivity gain over passive coupling. Meanwhile, a pumping signal at the sum frequency of the dipole mode and the lower butterfly mode can simultaneously activate multiple resonators in the same row, leading to 3-fold sensitivity gain over passive coupling. When multiple rows of detectors are parallelly aligned, each row has a unique lower butterfly frequency for consecutive activation during the acquisition interval of the others. This wireless detector array can be embedded beneath a headpost that is normally required for multi-modal brain imaging, enabling easy reconfiguration between focal imaging of individual vessels and multiregional mapping of brain connectivity.
Collapse
Affiliation(s)
- Wei Qian
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Xin Yu
- Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Chunqi Qian
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA
- Department of Radiology, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
14
|
Timilsina R, Qian C. Parallel magnetic resonance image reconstruction from a single-element parametric amplifier. Magn Reson Imaging 2019; 63:147-154. [PMID: 31425798 PMCID: PMC6861694 DOI: 10.1016/j.mri.2019.08.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 07/22/2019] [Accepted: 08/15/2019] [Indexed: 11/30/2022]
Abstract
In magnetic resonance imaging (MRI), acquisition speed is always an important issue. In this paper, we propose a promising technique to achieve parallel MRI (pMRI) on a single-channel spectrometer, using a novel Wireless Amplified Nuclear MR Detector (WAND) for spatial encoding in image reconstruction. For this, a planar structure double frequency WAND is designed and fabricated, where two of its frequencies - 'signal', ω1 and 'idler', ω2 are effectively utilized as two separate "channels" for accelerated acquisition. We provided a thorough background needed for the method and subsequently parallel imaging algorithms. Sum-of-Squares (SoS) reconstruction and GeneRalized Autocalibrating Partially Parallel Acquisition (GRAPPA) reconstruction are used to reconstruct as well as to analyze the SNR in the resulting images and validate our hypothesis. Experimental results using phantom datasets demonstrate that the proposed method of parallel imaging yield a better sensitivity for the combined images ('idler' + 'signal') than the sensitivity acquired for each individual image and thus significantly improving the reconstruction quality with optimal signal-to-noise ratio. We also demonstrated the achievable acceleration factor of this approach.
Collapse
Affiliation(s)
- Roshan Timilsina
- Department of Physics, Oakland University, Rochester, MI 48309, USA; Department of Radiology, Michigan State University, East Lansing, MI 48824, USA
| | - Chunqi Qian
- Department of Physics, Oakland University, Rochester, MI 48309, USA; Department of Radiology, Michigan State University, East Lansing, MI 48824, USA.
| |
Collapse
|
15
|
Zeng X, Ma S, Kruger JM, Wang R, Tan X, Qian C. High-resolution MRI of kidney microstructures at 7.05 T with an endo-colonic Wireless Amplified NMR detector. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 303:121-127. [PMID: 31051387 PMCID: PMC6590910 DOI: 10.1016/j.jmr.2019.04.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 04/19/2019] [Accepted: 04/21/2019] [Indexed: 05/06/2023]
Abstract
To map the hemodynamic responses of kidney microstructures at 7.05 T with improved sensitivity, a Wireless Amplified NMR Detector (WAND) with cylindrical symmetry was fabricated as an endoluminal detector that can convert externally provided wireless signal at 600.71 MHz into amplified MR signals at 300.33 MHz. When this detector was inserted inside colonic lumens to sensitively observe adjacent kidneys, it could clearly identify kidney microstructures in the renal cortex and renal medullary. Owing to the higher achievable spatial resolution, differential hemodynamic responses of kidney microstructures under different breathing conditions could be individually quantified to estimate the underlying correlation between oxygen bearing capability and local levels of oxygen unsaturation. The WAND's ability to map Blood Oxygen Level Dependent (BOLD) signal responses in heterogeneous microstructures will pave way for early-stage diagnosis of kidney diseases, without the use of contrast agents for reduced tissue retention and toxicity.
Collapse
Affiliation(s)
- Xianchun Zeng
- Department of Radiology, Guizhou Provincial People's Hospital, Guiyang, China; Department of Radiology, Michigan State University, East Lansing, MI, USA
| | - Shuangtao Ma
- Department of Medicine, Michigan State University, East Lansing, MI, USA
| | - John M Kruger
- Veterinary Medical Center, Michigan State University, East Lansing, MI, USA
| | - Rongpin Wang
- Department of Radiology, Guizhou Provincial People's Hospital, Guiyang, China
| | - Xiaobo Tan
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA
| | - Chunqi Qian
- Department of Radiology, Michigan State University, East Lansing, MI, USA.
| |
Collapse
|
16
|
Timilsina R, Fan B, Qian C. Signal Sensitivity Enhancement of High-Spatial-Resolution MR Imaging with a Concatenated Cylindrical Parametric RF-Resonator. IEEE SENSORS JOURNAL 2019; 19:3431-3438. [PMID: 31798350 PMCID: PMC6890421 DOI: 10.1109/jsen.2019.2894298] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Phased array MRI coils can increase sensitivity of superficial tissues owing to their proximity to the detection region. Deep-lying tissues, on the other hand, do not benefit to the same degree. Here we investigate the use of a localized cylindrically symmetric quadruple frequency resonator concatenated with a double frequency resonator to increase the longitudinal field-of-view (FOV) without compromising the spatial-resolution and detection sensitivity. These concatenated array coils work on the principle of a parametric amplification to provide wireless amplification of the locally detected NMR signal prior to inductively coupling the coil to an external pick-up loop with connection to the system receiver. When both the detectors are activated together, the effective range of both overlay to create a larger FOV enabling better identification of detectable regions. Furthermore, the in-vivo test of the concatenated detector provides a worst-case 5-fold SNR gain in regions separated from the cylindrical surface larger than its own diameter. This proposed approach of concatenated detector realization can be individually activated and manipulated to enlarge the sensitivity-enhanced region without sacrificing their individual performance. Compared to double frequency detectors, quadruple frequency detectors offer more flexibility in the choice of detector dimension, enabling multi-element concatenation over an extended FOV.
Collapse
Affiliation(s)
- Roshan Timilsina
- Department of Radiology, Michigan State University, and with the Department of Physics, Oakland University
| | - Baolei Fan
- Department of Radiology, Michigan State University, East Lansing, MI, 48824, USA, and with the Hubei University of Science and Technology, Xianning, China
| | | |
Collapse
|
17
|
Timilsina R, Qian C. A Novel Expandable Catheter Wireless Amplified NMR Detector for MR Sensitivity Accessing the Kidney in Rodent Model. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:444-453. [PMID: 30624224 PMCID: PMC6446567 DOI: 10.1109/tbcas.2018.2890657] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This paper demonstrates the enlarged effective range for MRI sensitivity enhancement with a deformable catheter MRI coils integrated with a wirelessly powered amplifier. The expandable balloon wireless amplified nuclear magnetic resonance detector (WAND) is constructed on a copper-clad polyimide film to resonate at the first and second harmonics of the proton Larmor frequency at 7 Tesla. The WAND is then mounted on a balloon catheter system for easy delivery inside confined orifice. Upon reaching the region of interest, it is unfolded out of the sheath tube to increase its effective size. Magnetic resonance (MR) imaging experiments with and without the WAND are performed both in a water phantom and in a live rat to evaluate the WAND's sensitivity advantage. Expanded from a 3 mm diameter in its folded state, this deformable WAND can change its width by >100% in its inflated state to at least 6 mm, leading to a sensitive detection region extending to up to 20 mm in the transverse direction. When the deformable WAND is placed in an artery in the region of the kidney of a live rat, it could achieve at least a 10-fold SNR gain over images acquired by a standard external detector of 22 mm diameter, even though the region of interest is separated from the WAND's surface by a distance larger than the WAND's own width. The proposed expandable catheter WAND could significantly enlarge the effective range for MR sensitivity enhancement in-vivo, enabling versatile applications in interventional MRI.
Collapse
|
18
|
Zeng X, Xu S, Cao C, Wang J, Qian C. Wireless amplified NMR detector for improved visibility of image contrast in heterogeneous lesions. NMR IN BIOMEDICINE 2018; 31:e3963. [PMID: 30011104 PMCID: PMC6108921 DOI: 10.1002/nbm.3963] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 05/17/2018] [Accepted: 05/23/2018] [Indexed: 05/23/2023]
Abstract
To demonstrate the capability of a wireless amplified NMR detector (WAND) to improve the visibility of lesion heterogeneity without the use of exogenous contrast agents, a cylindrically symmetric WAND was constructed to sensitively detect and simultaneously amplify MR signals emitted from adjacent tissues. Based on a two-leg high-pass birdcage coil design, this WAND could be activated by a pumping field aligned along the main field (B0 ), without perturbing MR signal reception. Compared with an equivalent pair of external detectors, the WAND could achieve more than 10-fold gain for immediately adjacent regions. Even for regions with 3.4 radius distance separation from the detector's cylindrical center, the WAND was at least 1.4 times more sensitive than an equivalent pair of surface arrays or at least twice as sensitive as a single-sided external surface detector. When the WAND was inserted into a rat's rectum to observe adjacent tumors implanted beneath the mucosa, it could enhance the detection sensitivity of lesion regions, and thus enlarge the observable signal difference between heterogeneous tissues and clearly identify lesion boundaries as continuous lines in the intensity gradient profile. Hyperintense regions observable by the WAND existed due to higher levels of blood supply, which was indicated by a similar pattern of signal enhancement after contrast agent administration. By better observing the endogenous signal contrast, the endoluminal WAND could characterize lesions without the use of exogenous contrast agents, and thus reduce contrast-induced toxicity.
Collapse
Affiliation(s)
- Xianchun Zeng
- Department of Radiology, Southwest Hospital, Army Medical University, Chongqing, China
- Department of Radiology, Guizhou Provincial People’s Hospital, Guiyang, China
- Department of Radiology, Michigan State University, East Lansing, MI, USA
| | - Shengqiang Xu
- Department of Radiology, Michigan State University, East Lansing, MI, USA
| | - Changyong Cao
- Laboratory of Soft Machines and Electronics, School of Packaging, Departments of Mechanical, Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA
| | - Jian Wang
- Department of Radiology, Southwest Hospital, Army Medical University, Chongqing, China
- Correspondence: Jian Wang, 30 Gaotanyan Rd, Chongqing, China, 400038, Tel: +86 (23) 68754419; Fax: +86 (23) 65463026, , Chunqi Qian, 846 Service Rd, East Lansing, MI, 48824, Tel: +1 (517) 884-3292; Fax: +1 (517) 432-2849,
| | - Chunqi Qian
- Department of Radiology, Michigan State University, East Lansing, MI, USA
- Correspondence: Jian Wang, 30 Gaotanyan Rd, Chongqing, China, 400038, Tel: +86 (23) 68754419; Fax: +86 (23) 65463026, , Chunqi Qian, 846 Service Rd, East Lansing, MI, 48824, Tel: +1 (517) 884-3292; Fax: +1 (517) 432-2849,
| |
Collapse
|
19
|
Enomoto A, Qian C, Devasahayam N, Kishimoto S, Oshima N, Blackman B, Swenson RE, Mitchell JB, Koretsky AP, Krishna MC. Wireless implantable coil with parametric amplification for in vivo electron paramagnetic resonance oximetric applications. Magn Reson Med 2018; 80:2288-2298. [PMID: 29603378 DOI: 10.1002/mrm.27185] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 02/23/2018] [Accepted: 02/28/2018] [Indexed: 11/06/2022]
Abstract
PURPOSE To develop an implantable wireless coil with parametric amplification capabilities for time-domain electron paramagnetic resonance (EPR) spectroscopy operating at 300 MHz. METHODS The wireless coil and lithium phthalocyanine (LiPc), a solid paramagnetic probe, were each embedded individually in a biocompatible polymer polydimethoxysiloxane (PDMS). EPR signals from the LiPc embedded in PDMS (LiPc/PDMS) were generated by a transmit-receive surface coil tuned to 300 MHz. Parametric amplification was configured with an external pumping coil tuned to 600 MHz and placed between the surface coil resonator and the wireless coil. RESULTS Phantom studies showed significant enhancement in signal to noise using the pumping coil. However, no influence of the pumping coil on the oxygen-dependent EPR spectral linewidth of LiPc/PDMS was observed, suggesting the validity of parametric amplification of EPR signals for oximetry by implantation of the encapsulated wireless coil and LiPc/PDMS in deep regions of live objects. In vivo studies demonstrate the feasibility of this approach to longitudinally monitor tissue pO2 in vivo and also monitor acute changes in response to pharmacologic challenges. The encapsulated wireless coil and LiPc/PDMS engendered no host immune response when implanted for ∼3 weeks and were found to be well tolerated. CONCLUSIONS This approach may find applications for monitoring tissue oxygenation to better understand the pathophysiology associated with wound healing, organ transplantation, and ischemic diseases.
Collapse
Affiliation(s)
- Ayano Enomoto
- Radiation Biology Branch, Center for Cancer Research, NCI, NIH, Bethesda, Maryland
| | - Chunqi Qian
- Laboratory of Functional and Molecular Imaging, NINDS, NIH, Bethesda, Maryland.,Department of Radiology, Michigan State University, East Lansing, Michigan
| | | | - Shun Kishimoto
- Radiation Biology Branch, Center for Cancer Research, NCI, NIH, Bethesda, Maryland
| | - Nobu Oshima
- Urologic Oncology Branch, Center for Cancer Research, NCI, NIH, Bethesda, Maryland
| | | | - Rolf E Swenson
- Image Probe Development Center, NHLBI, NIH, Bethesda, Maryland
| | - James B Mitchell
- Radiation Biology Branch, Center for Cancer Research, NCI, NIH, Bethesda, Maryland
| | - Alan P Koretsky
- Laboratory of Functional and Molecular Imaging, NINDS, NIH, Bethesda, Maryland
| | - Murali C Krishna
- Radiation Biology Branch, Center for Cancer Research, NCI, NIH, Bethesda, Maryland
| |
Collapse
|
20
|
Baldelomar EJ, Charlton JR, Beeman SC, Bennett KM. Measuring rat kidney glomerular number and size in vivo with MRI. Am J Physiol Renal Physiol 2017; 314:F399-F406. [PMID: 29092847 DOI: 10.1152/ajprenal.00399.2017] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
number is highly variable in humans and is thought to play an important role in renal health. Chronic kidney disease (CKD) is the result of too few nephrons to maintain homeostasis. Currently, nephron number can only be determined invasively or as a terminal assessment. Due to a lack of tools to measure and track nephron number in the living, the early stages of CKD often go unrecognized, preventing early intervention that might halt the progression of CKD. In this work, we present a technique to directly measure glomerular number ( Nglom) and volume in vivo in the rat kidney ( n = 8) using MRI enhanced with the novel contrast agent cationized ferritin (CFE-MRI). Adult male rats were administered intravenous cationized ferritin (CF) and imaged in vivo with MRI. Glomerular number was measured and each glomerulus was spatially mapped in 3D in the image. Mean apparent glomerular volume (a Vglom) and intrarenal distribution of the individual glomerular volume (IGV), were also measured. These metrics were compared between images of the same kidneys scanned in vivo and ex vivo with CFE-MRI. In vivo Nglom and a Vglom correlated to ex vivo metrics within the same kidneys and were within 10% of Nglom and a Vglom previously validated by stereologic methods. This is the first report of direct in vivo measurements of Nglom and a Vglom, introducing an opportunity to investigate mechanisms of renal disease progression and therapeutic response over time.
Collapse
Affiliation(s)
| | - Jennifer R Charlton
- University of Virginia , Department of Pediatrics, Charlottesville, Virginia
| | - Scott C Beeman
- Washington University School of Medicine , Mallinckrodt Institute of Radiology, St. Louis, Missouri
| | - Kevin M Bennett
- University of Hawaii at Manoa, Department of Biology , Honolulu, Hawaii
| |
Collapse
|
21
|
Wireless MRI Colonoscopy for Sensitive Imaging of Vascular Walls. Sci Rep 2017; 7:4228. [PMID: 28652614 PMCID: PMC5484665 DOI: 10.1038/s41598-017-03902-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Accepted: 05/08/2017] [Indexed: 01/08/2023] Open
Abstract
A Wireless Amplified NMR Detector (WAND) with cylindrical symmetry has been fabricated and non-surgically inserted into a rodent lower digestive track to improve the imaging quality of deep-lying vessels inside the abdominal cavity. This symmetric detector has a compact design using two end-rings and two vertical legs to create two orthogonal resonance modes. Based on the principle of parametric amplification, the detector can harvest wireless pumping power with its end-rings and amplify Magnetic Resonance signals induced on its vertical legs. With good longitudinal and azimuthal homogeneity, the WAND can achieve up to 21-times sensitivity gain over a standard external detector for immediately adjacent regions, and at least 5-times sensitivity gain for regions separated by one diameter away from the detector's cylindrical surface. The WAND can approach the region of interest through the lower digestive track, similar as a colonoscopy detector. But unlike an optical camera, the amplified MR detector can "see" across intestinal boundaries and clearly identify the walls of bifurcated vessels that are susceptible to atherosclerotic lesions. In addition to vascular wall imaging, this detector may also be used as a swallowable capsule to enhance the detection sensitivity of deep-lying organs near the digestive track.
Collapse
|
22
|
Wang X, Garrett MR. Nephron number, hypertension, and CKD: physiological and genetic insight from humans and animal models. Physiol Genomics 2017; 49:180-192. [PMID: 28130427 DOI: 10.1152/physiolgenomics.00098.2016] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The kidneys play a vital role in the excretion of waste products and the regulation of electrolytes, maintenance of acid-base balance, regulation of blood pressure, and production of several hormones. Any alteration in the structure of the nephron (basic functional unit of the kidney) can have a major impact on the kidney's ability to work efficiently. Progressive decline in kidney function can lead to serious illness and ultimately death if not treated by dialysis or transplantation. While there have been numerous studies that implicate lower nephron numbers as being an important factor in influencing susceptibility to developing hypertension and chronic kidney disease, a direct association has been difficult to establish because of three main limitations: 1) the large variation in nephron number observed in the human population; 2) no established reliable noninvasive methods to determine nephron complement; and 3) to date, nephron measurements have been done after death, which doesn't adequately account for potential loss of nephrons with age or disease. In this review, we will provide an overview of kidney structure/function, discuss the current literature for both humans and other species linking nephron deficiency and cardio-renal complications, as well as describe the major molecular signaling factors involved in nephrogenesis that modulate variation in nephron number. As more detailed knowledge about the molecular determinants of nephron development and the role of nephron endowment in the cardio-renal system is obtained, it will hopefully provide clinicians the ability to accurately identify people at risk to develop CKD/hypertension and lead to a shift in patient care from disease treatment to prevention.
Collapse
Affiliation(s)
- Xuexiang Wang
- Department of Pharmacology and Toxicology, University of Mississippi Medical Center, Jackson, Mississippi; and
| | - Michael R Garrett
- Department of Pharmacology and Toxicology, University of Mississippi Medical Center, Jackson, Mississippi; and .,Department of Medicine (Nephrology) and Pediatrics (Genetics), University of Mississippi Medical Center, Jackson, Mississippi
| |
Collapse
|
23
|
Zeng X, Barbic M, Chen L, Qian C. Sensitive enhancement of vessel wall imaging with an endoesophageal Wireless Amplified NMR Detector (WAND). Magn Reson Med 2016; 78:2048-2054. [PMID: 27917520 DOI: 10.1002/mrm.26562] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Revised: 11/03/2016] [Accepted: 11/03/2016] [Indexed: 11/06/2022]
Abstract
PURPOSE To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can convert wirelessly provided pumping power into amplified MR signals. This compact design makes the detector easily insertable into a rodent esophagus. RESULTS The detector has good longitudinal and axial symmetry. Compared to an external surface coil, the WAND can enhance detection sensitivity by at least 5 times, even when the distance separation between the region of interest and the detector's cylindrical surface is twice the detector's own radius. Such detection capability enables us to observe vessel walls near the aortic arch and carotid bifurcation with elevated sensitivity. CONCLUSION A cylindrical MRI detector integrated with a wireless-powered amplifier has been developed as an endoesophageal detector to enhance detection sensitivity of vessel walls. This detector can greatly improve the imaging quality for vessel regions that are susceptible to atherosclerotic lesions. Magn Reson Med 78:2048-2054, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Xianchun Zeng
- Department of Radiology, Guizhou Provincial People's Hospital, Guiyang, China.,Department of Radiology, Michigan State University, East Lansing, Michigan, USA
| | - Mladen Barbic
- Applied Physics and Instrumentation Group, Howard Huge Medical Institute, Janelia Research Campus, Ashburn, Virginia, USA
| | - Liangliang Chen
- Department of Radiology, Michigan State University, East Lansing, Michigan, USA
| | - Chunqi Qian
- Department of Radiology, Michigan State University, East Lansing, Michigan, USA
| |
Collapse
|
24
|
Xie L, Bennett KM, Liu C, Johnson GA, Zhang JL, Lee VS. MRI tools for assessment of microstructure and nephron function of the kidney. Am J Physiol Renal Physiol 2016; 311:F1109-F1124. [PMID: 27630064 DOI: 10.1152/ajprenal.00134.2016] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 09/08/2016] [Indexed: 12/13/2022] Open
Abstract
MRI can provide excellent detail of renal structure and function. Recently, novel MR contrast mechanisms and imaging tools have been developed to evaluate microscopic kidney structures including the tubules and glomeruli. Quantitative MRI can assess local tubular function and is able to determine the concentrating mechanism of the kidney noninvasively in real time. Measuring single nephron function is now a near possibility. In parallel to advancing imaging techniques for kidney microstructure is a need to carefully understand the relationship between the local source of MRI contrast and the underlying physiological change. The development of these imaging markers can impact the accurate diagnosis and treatment of kidney disease. This study reviews the novel tools to examine kidney microstructure and local function and demonstrates the application of these methods in renal pathophysiology.
Collapse
Affiliation(s)
- Luke Xie
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah;
| | - Kevin M Bennett
- Department of Biology, University of Hawaii at Manoa, Honolulu, Hawaii
| | - Chunlei Liu
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, North Carolina; and.,Brain Imaging and Analysis Center, Duke University Medical Center, Durham, North Carolina
| | - G Allan Johnson
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, North Carolina; and
| | - Jeff Lei Zhang
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah
| | - Vivian S Lee
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah
| |
Collapse
|
25
|
Charlton JR, Pearl VM, Denotti AR, Lee JB, Swaminathan S, Scindia YM, Charlton NP, Baldelomar EJ, Beeman SC, Bennett KM. Biocompatibility of ferritin-based nanoparticles as targeted MRI contrast agents. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2016; 12:1735-45. [PMID: 27071333 PMCID: PMC4955692 DOI: 10.1016/j.nano.2016.03.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2015] [Revised: 02/24/2016] [Accepted: 03/26/2016] [Indexed: 10/22/2022]
Abstract
Ferritin is a naturally occurring iron storage protein, proposed as a clinically relevant nanoparticle with applications as a diagnostic and therapeutic agent. Cationic ferritin is a targeted, injectable contrast agent to measure kidney microstructure with MRI. Here, the toxicity of horse spleen ferritin is assessed as a step to clinical translation. Adult male mice received cationic, native and high dose cationic ferritin (CF, NF, or HDCF) or saline and were monitored for 3weeks. Transient weight loss occurred in the ferritin groups with no difference in renal function parameters. Ferritin-injected mice demonstrated a lower serum iron 3weeks after administration. In ferritin-injected animals pre-treated with hydrocortisone, there were no structural or weight differences in the kidneys, liver, lung, heart, or spleen. This study demonstrates a lack of significant detrimental effects of horse-derived ferritin-based nanoparticles at MRI-detectable doses, allowing further exploration of these agents in basic research and clinical diagnostics.
Collapse
Affiliation(s)
- Jennifer R Charlton
- University of Virginia, Department of Pediatrics, Division of Nephrology, Charlottesville VA, USA.
| | - Valeria M Pearl
- University of Virginia, Department of Pediatrics, Division of Nephrology, Charlottesville VA, USA.
| | - Anna R Denotti
- Ospedale Regionale per le Microcitemie, University of Cagliari, Italy, Department of Pediatrics.
| | - Jonathan B Lee
- Eastern Virginia Medical School, Department of Pediatrics, Norfolk, VA, USA.
| | - Sundararaman Swaminathan
- University of Virginia, Center for Immunity, Inflammation and Regenerative Medicine and Department of Medicine, Division of Nephrology, Charlottesville VA, USA.
| | - Yogesh M Scindia
- University of Virginia, Center for Immunity, Inflammation and Regenerative Medicine and Department of Medicine, Division of Nephrology, Charlottesville VA, USA.
| | - Nathan P Charlton
- University of Virginia, Department of Emergency Medicine, Division of Medical Toxicology, Charlottesville, VA, USA.
| | - Edwin J Baldelomar
- University of Hawaii at Manoa, Department of Physics, Honolulu, HI, USA.
| | - Scott C Beeman
- Washington University School of Medicine, Department of Radiology, St. Louis, MO, USA.
| | - Kevin M Bennett
- University of Hawaii at Manoa, Department of Biology, Honolulu, HI.
| |
Collapse
|
26
|
Baldelomar EJ, Charlton JR, Beeman SC, Hann BD, Cullen-McEwen L, Pearl VM, Bertram JF, Wu T, Zhang M, Bennett KM. Phenotyping by magnetic resonance imaging nondestructively measures glomerular number and volume distribution in mice with and without nephron reduction. Kidney Int 2016; 89:498-505. [PMID: 26535998 PMCID: PMC4854807 DOI: 10.1038/ki.2015.316] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Revised: 07/23/2015] [Accepted: 08/20/2015] [Indexed: 12/29/2022]
Abstract
Reduced nephron mass is strongly linked to susceptibility to chronic renal and cardiovascular diseases. There are currently no tools to identify nephropenia in clinical or preclinical diagnostics. Such new methods could uncover novel mechanisms and therapies for chronic kidney disease (CKD) and reveal how variation among traits can affect renal function and morphology. Here we used cationized ferritin (CF)–enhanced MRI (CFE-MRI) to investigate the relationship between glomerular number (Nglom) and volume (Vglom) in kidneys of healthy wild-type mice and mice with oligosyndactylism (Os/+), a model of congenital nephron reduction. Mice were injected with CF and perfused, and the resected kidneys were imaged with 7T MRI to detect CF-labeled glomeruli. CFE-MRI was used to measure the intrarenal distribution of individual glomerular volumes and revealed two major populations of glomeruli distinguished by size. Spatial mapping revealed that the largest glomeruli were located in the juxtamedullary region in both wild-type and Os/+ mice and the smallest population located in the cortex. Os/+ mice had about a 50% reduction and 35% increase of Nglom and Vglom, respectively, in both glomerular populations compared with wild type, consistent with glomerular hypertrophy in the Os/+ mice. Thus, we provide a foundation for whole-kidney, MRI-based phenotyping of mouse renal glomerular morphology and provide new potential for quantitative human renal diagnostics.
Collapse
Affiliation(s)
- Edwin J. Baldelomar
- University of Hawaii at Manoa, Department of Physics, Honolulu, Hawaii, USA
- University of Hawaii at Manoa, Department of Biology, Honolulu, Hawaii, USA
| | | | - Scott C. Beeman
- Washington University School of Medicine, Saint Louis, Missouri, USA
| | - Bradley D. Hann
- University of Hawaii at Manoa, Department of Molecular Biosciences and Bioengineering, Honolulu, Hawaii, USA
- University of Hawaii at Manoa, Department of Biology, Honolulu, Hawaii, USA
| | | | | | | | - Teresa Wu
- Arizona State University, Tempe, Arizona, USA
| | - Min Zhang
- Arizona State University, Tempe, Arizona, USA
| | - Kevin M. Bennett
- University of Hawaii at Manoa, Department of Biology, Honolulu, Hawaii, USA
| |
Collapse
|
27
|
Qian C, Duan Q, Dodd S, Koretsky A, Murphy-Boesch J. Sensitivity Enhancement of an Inductively Coupled Local Detector Using a HEMT-Based Current Amplifier. Magn Reson Med 2015; 75:2573-8. [PMID: 26192998 DOI: 10.1002/mrm.25850] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Revised: 06/12/2015] [Accepted: 06/27/2015] [Indexed: 01/26/2023]
Abstract
PURPOSE To improve the signal transmission efficiency and sensitivity of a local detection coil that is weakly inductively coupled to a larger receive coil. METHODS The resonant detection coil is connected in parallel with the gate of a high electron mobility transistor (HEMT) transistor without impedance matching. When the drain of the transistor is capacitively shunted to ground, current amplification occurs in the resonator by feedback that transforms a capacitive impedance on the transistor's source to a negative resistance on its gate. RESULTS High resolution images were obtained from a mouse brain using a small, 11 mm diameter surface coil that was inductively coupled to a commercial, phased array chest coil. Although the power consumption of the amplifier was only 88 μW, 14 dB gain was obtained with excellent noise performance. CONCLUSION An integrated current amplifier based on a HEMT can enhance the sensitivity of inductively coupled local detectors when weakly coupled. This amplifier enables efficient signal transmission between customized user coils and commercial clinical coils, without the need for a specialized signal interface. Magn Reson Med 75:2573-2578, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Collapse
Affiliation(s)
- Chunqi Qian
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA.,Department of Radiology, Michigan State University, East Lansing, Michigan, USA
| | - Qi Duan
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| | - Steve Dodd
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| | - Alan Koretsky
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| | - Joe Murphy-Boesch
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
28
|
Jutz G, van Rijn P, Santos Miranda B, Böker A. Ferritin: a versatile building block for bionanotechnology. Chem Rev 2015; 115:1653-701. [PMID: 25683244 DOI: 10.1021/cr400011b] [Citation(s) in RCA: 272] [Impact Index Per Article: 30.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Günther Jutz
- DWI - Leibniz-Institut für Interaktive Materialien e.V., Lehrstuhl für Makromolekulare Materialien und Oberflächen, RWTH Aachen University , Forckenbeckstrasse 50, D-52056 Aachen, Germany
| | | | | | | |
Collapse
|
29
|
Qian C, Yu X, Pothayee N, Dodd S, Bouraoud N, Star R, Bennett K, Koretsky A. Live nephron imaging by MRI. Am J Physiol Renal Physiol 2014; 307:F1162-8. [PMID: 25186296 DOI: 10.1152/ajprenal.00326.2014] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
The local sensitivity of MRI can be improved with small MR detectors placed close to regions of interest. However, to maintain such sensitivity advantage, local detectors normally need to communicate with the external amplifier through cable connections, which prevent the use of local detectors as implantable devices. Recently, an integrated wireless amplifier was developed that can efficiently amplify and broadcast locally detected signals, so that the local sensitivity was enhanced without the need for cable connections. This integrated detector enabled the live imaging of individual glomeruli using negative contrast introduced by cationized ferritin, and the live imaging of renal tubules using positive contrast introduced by gadopentetate dimeglumine. Here, we utilized the high blood flow to image individual glomeruli as hyperintense regions without any contrast agent. These hyperintense regions were identified for pixels with signal intensities higher than the local average. Addition of Mn(2+) allowed the simultaneous detection of both glomeruli and renal tubules: Mn(2+) was primarily reabsorbed by renal tubules, which would be distinguished from glomeruli due to higher enhancement in T1-weighted MRI. Dynamic studies of Mn(2+) absorption confirmed the differential absorption affinity of glomeruli and renal tubules, potentially enabling the in vivo observation of nephron function.
Collapse
Affiliation(s)
- Chunqi Qian
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorder and Stroke, National Institutes of Health, Bethesda, Maryland;
| | - Xin Yu
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorder and Stroke, National Institutes of Health, Bethesda, Maryland; High-Field Magnetic Resonance Department, Max Planck Institute for Biological Cybernetics, Tubingen, Germany
| | - Nikorn Pothayee
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorder and Stroke, National Institutes of Health, Bethesda, Maryland
| | - Stephen Dodd
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorder and Stroke, National Institutes of Health, Bethesda, Maryland
| | - Nadia Bouraoud
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorder and Stroke, National Institutes of Health, Bethesda, Maryland
| | - Robert Star
- Division of Kidney Urologic and Hematologic Diseases, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland
| | - Kevin Bennett
- Department of Biology, University of Hawaii, Honolulu, Hawaii; and
| | - Alan Koretsky
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorder and Stroke, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
30
|
Bertram JF, Cullen-McEwen LA, Egan GF, Gretz N, Baldelomar E, Beeman SC, Bennett KM. Why and how we determine nephron number. Pediatr Nephrol 2014; 29:575-80. [PMID: 24022365 DOI: 10.1007/s00467-013-2600-y] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Revised: 07/25/2013] [Accepted: 08/02/2013] [Indexed: 01/23/2023]
Abstract
The total number of glomeruli (nephrons) in a kidney is an important microanatomical parameter for at least three reasons: it provides an index of the success/extent of nephrogenesis and can thereby provide insights into the roles of specific genes and feto-maternal environmental factors in nephrogenesis; low nephron number has been linked to an increased risk of cardiovascular and renal disease in adulthood; and knowledge of quantitative kidney microanatomy can illuminate our understanding of physiological mechanisms in health and disease. A range of methods has been used to count glomeruli in kidneys over the past 100 years, with design-based stereology (the physical disector/fractionator combination) considered the gold standard. However, this approach is labor-intensive and expensive, and therefore is not utilized by most laboratories. A new method for counting and sizing every glomerulus in the kidney has recently been described. This method involves in vivo labeling of glomeruli with cationic ferritin, and then magnetic resonance imaging (MRI) of the ex vivo kidney. Values are obtained in one sixth of the time of disector-based approaches. This new MRI method holds great promise for studies of glomerular number and size ex vivo and in vivo.
Collapse
|
31
|
Beeman SC, Cullen-McEwen LA, Puelles VG, Zhang M, Wu T, Baldelomar EJ, Dowling J, Charlton JR, Forbes MS, Ng A, Wu QZ, Armitage JA, Egan GF, Bertram JF, Bennett KM. MRI-based glomerular morphology and pathology in whole human kidneys. Am J Physiol Renal Physiol 2014; 306:F1381-90. [PMID: 24647716 DOI: 10.1152/ajprenal.00092.2014] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Nephron number (N(glom)) and size (V(glom)) are correlated with risk for chronic cardiovascular and kidney disease and may be predictive of renal allograft viability. Unfortunately, there are no techniques to assess N(glom) and V(glom) in intact kidneys. This work demonstrates the use of cationized ferritin (CF) as a magnetic resonance imaging (MRI) contrast agent to measure N(glom) and V(glom) in viable human kidneys donated to science. The kidneys were obtained from patients with varying levels of cardiovascular and renal disease. CF was intravenously injected into three viable human kidneys. A fourth control kidney was perfused with saline. After fixation, immunofluorescence and electron microscopy confirmed binding of CF to the glomerulus. The intact kidneys were imaged with three-dimensional MRI and CF-labeled glomeruli appeared as punctate spots. Custom software identified, counted, and measured the apparent volumes of CF-labeled glomeruli, with an ~6% false positive rate. These measurements were comparable to stereological estimates. The MRI-based technique yielded a novel whole kidney distribution of glomerular volumes. Histopathology demonstrated that the distribution of CF-labeled glomeruli may be predictive of glomerular and vascular disease. Variations in CF distribution were quantified using image texture analyses, which be a useful marker of glomerular sclerosis. This is the first report of direct measurement of glomerular number and volume in intact human kidneys.
Collapse
Affiliation(s)
- Scott C Beeman
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri
| | - Luise A Cullen-McEwen
- Department of Anatomy and Developmental Biology, Monash University, Melbourne, Victoria, Australia
| | - Victor G Puelles
- Department of Anatomy and Developmental Biology, Monash University, Melbourne, Victoria, Australia
| | - Min Zhang
- School of Computing, Informatics, and Decision Systems Engineering, Arizona State University, Tempe, Arizona
| | - Teresa Wu
- School of Computing, Informatics, and Decision Systems Engineering, Arizona State University, Tempe, Arizona
| | - Edwin J Baldelomar
- Department of Physics, College of Natural Sciences, University of Hawaii at Manoa, Honolulu, Hawaii
| | - John Dowling
- Department of Anatomical Pathology, Monash Medical Centre, Clayton, Victoria, Australia
| | - Jennifer R Charlton
- Department of Pediatrics, Division of Nephrology, University of Virginia Medical Center, Charlottesville, Virginia
| | - Michael S Forbes
- Department of Pediatrics, Division of Nephrology, University of Virginia Medical Center, Charlottesville, Virginia
| | - Amanda Ng
- Monash Biomedical Imaging, Monash University, Melbourne, Australia; and
| | - Qi-zhu Wu
- Monash Biomedical Imaging, Monash University, Melbourne, Australia; and
| | - James A Armitage
- Department of Anatomy and Developmental Biology, Monash University, Melbourne, Victoria, Australia
| | - Gary F Egan
- Monash Biomedical Imaging, Monash University, Melbourne, Australia; and
| | - John F Bertram
- Department of Anatomy and Developmental Biology, Monash University, Melbourne, Victoria, Australia
| | - Kevin M Bennett
- Department of Biology, College of Natural Sciences, University of Hawaii at Manoa, Honolulu, Hawaii
| |
Collapse
|
32
|
Charlton JR, Beeman SC, Bennett KM. MRI-detectable nanoparticles: the potential role in the diagnosis of and therapy for chronic kidney disease. Adv Chronic Kidney Dis 2013; 20:479-87. [PMID: 24206600 DOI: 10.1053/j.ackd.2013.06.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Revised: 05/23/2013] [Accepted: 06/03/2013] [Indexed: 12/30/2022]
Abstract
Chronic kidney disease (CKD) is a common, deadly, and expensive threat to public health. Patients susceptible to the development of CKD are difficult to identify because there are few noninvasive clinical techniques and markers to assess early kidney dysfunction. Noninvasive imaging techniques are being developed to quantitatively measure kidney morphology and function in preclinical research and in clinical trials. Magnetic resonance imaging (MRI) techniques in particular have the potential to provide structural and functional information in the kidney. Novel molecular imaging techniques, using targeted magnetic nanoparticles that exploit the characteristics of the endogenous protein, ferritin, have been developed in conjunction with MRI to count every perfused glomerulus in the kidney and measure their individual volumes. This technique could open the door to the possibility of prospectively assessing and eventually reducing a patient's risk for progression to CKD. This review highlights the potential clinical benefits of early detection in patients predisposed to CKD and discusses technologic and regulatory hurdles to the translation of these molecular MRI techniques to provide early diagnosis of CKD.
Collapse
|
33
|
Bennett KM, Bertram JF, Beeman SC, Gretz N. The emerging role of MRI in quantitative renal glomerular morphology. Am J Physiol Renal Physiol 2013; 304:F1252-7. [PMID: 23515719 DOI: 10.1152/ajprenal.00714.2012] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Techniques to measure morphological parameters, such as glomerular (and thereby nephron) number, glomerular size, and kidney volume, have been vital to understanding factors contributing to chronic kidney disease (CKD). These techniques have also been important to understanding the associations between CKD and other systemic and cardiovascular diseases and have led to the identification of developmental risk factors for these pathologies. However, existing techniques in quantitative kidney morphology are resource- and time-consuming and are destructive to the organ. This review discusses the emerging generation of techniques to study kidney morphology quantitatively using magnetic resonance imaging (MRI) using the intravenous injection of the superparamagnetic nanoparticle cationic ferritin, which binds to the glomerular basement membrane. A primary advantage of MRI over previously established techniques is the ability to quantify morphology in the intact organ with minimal sample preparation. We highlight areas of research where MRI-based morphological measurements will be helpful in animal models and possibly diagnostic clinical nephrology, discuss technical challenges in light of the progress in MRI techniques to date, and identify novel measurements that may be possible using MRI, both ex vivo and in vivo.
Collapse
Affiliation(s)
- K M Bennett
- Department of Biology, College of Natural Sciences, University of Hawaii at Manoa, Honolulu, HI 96822, USA.
| | | | | | | |
Collapse
|