1
|
Bajo-Fernández M, Souza-Silva ÉA, Barbas C, Rey-Stolle MF, García A. GC-MS-based metabolomics of volatile organic compounds in exhaled breath: applications in health and disease. A review. Front Mol Biosci 2024; 10:1295955. [PMID: 38298553 PMCID: PMC10828970 DOI: 10.3389/fmolb.2023.1295955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 12/05/2023] [Indexed: 02/02/2024] Open
Abstract
Exhaled breath analysis, with particular emphasis on volatile organic compounds, represents a growing area of clinical research due to its obvious advantages over other diagnostic tests. Numerous pathologies have been extensively investigated for the identification of specific biomarkers in exhalates through metabolomics. However, the transference of breath tests to clinics remains limited, mainly due to deficiency in methodological standardization. Critical steps include the selection of breath sample types, collection devices, and enrichment techniques. GC-MS is the reference analytical technique for the analysis of volatile organic compounds in exhalates, especially during the biomarker discovery phase in metabolomics. This review comprehensively examines and compares metabolomic studies focusing on cancer, lung diseases, and infectious diseases. In addition to delving into the experimental designs reported, it also provides a critical discussion of the methodological aspects, ranging from the experimental design and sample collection to the identification of potential pathology-specific biomarkers.
Collapse
Affiliation(s)
- María Bajo-Fernández
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Érica A. Souza-Silva
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
- Departmento de Química, Universidade Federal de São Paulo (UNIFESP), Diadema, Brazil
| | - Coral Barbas
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Ma Fernanda Rey-Stolle
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Antonia García
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| |
Collapse
|
2
|
A pilot study for the prediction of liver function related scores using breath biomarkers and machine learning. Sci Rep 2022; 12:2032. [PMID: 35132067 PMCID: PMC8821604 DOI: 10.1038/s41598-022-05808-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 01/13/2022] [Indexed: 02/07/2023] Open
Abstract
Volatile organic compounds (VOCs) present in exhaled breath can help in analysing biochemical processes in the human body. Liver diseases can be traced using VOCs as biomarkers for physiological and pathophysiological conditions. In this work, we propose non-invasive and quick breath monitoring approach for early detection and progress monitoring of liver diseases using Isoprene, Limonene, and Dimethyl sulphide (DMS) as potential biomarkers. A pilot study is performed to design a dataset that includes the biomarkers concentration analysed from the breath sample before and after study subjects performed an exercise. A machine learning approach is applied for the prediction of scores for liver function diagnosis. Four regression methods are performed to predict the clinical scores using breath biomarkers data as features set by the machine learning techniques. A significant difference was observed for isoprene concentration (p < 0.01) and for DMS concentration (p < 0.0001) between liver patients and healthy subject's breath sample. The R-square value between actual clinical score and predicted clinical score is found to be 0.78, 0.82, and 0.85 for CTP score, APRI score, and MELD score, respectively. Our results have shown a promising result with significant different breath profiles between liver patients and healthy volunteers. The use of machine learning for the prediction of scores is found very promising for use of breath biomarkers for liver function diagnosis.
Collapse
|
3
|
Khoubnasabjafari M, Mogaddam MRA, Rahimpour E, Soleymani J, Saei AA, Jouyban A. Breathomics: Review of Sample Collection and Analysis, Data Modeling and Clinical Applications. Crit Rev Anal Chem 2021; 52:1461-1487. [PMID: 33691552 DOI: 10.1080/10408347.2021.1889961] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Metabolomics research is rapidly gaining momentum in disease diagnosis, on top of other Omics technologies. Breathomics, as a branch of metabolomics is developing in various frontiers, for early and noninvasive monitoring of disease. This review starts with a brief introduction to metabolomics and breathomics. A number of important technical issues in exhaled breath collection and factors affecting the sampling procedures are presented. We review the recent progress in metabolomics approaches and a summary of their applications on the respiratory and non-respiratory diseases investigated by breath analysis. Recent reports on breathomics studies retrieved from Scopus and Pubmed were reviewed in this work. We conclude that analyzing breath metabolites (both volatile and nonvolatile) is valuable in disease diagnoses, and therefore believe that breathomics will turn into a promising noninvasive discipline in biomarker discovery and early disease detection in personalized medicine. The problem of wide variations in the reported metabolite concentrations from breathomics studies should be tackled by developing more accurate analytical methods and sophisticated numerical analytical alogorithms.
Collapse
Affiliation(s)
- Maryam Khoubnasabjafari
- Tuberculosis and Lung Diseases Research Center and Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.,Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohamad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.,Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Elaheh Rahimpour
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran.,Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Jafar Soleymani
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran.,Liver and Gastrointestinal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Amir Ata Saei
- Department of Medical Biochemistry and Biophysics, Division of Physiological Chemistry I, Karolinska Institutet, Stockholm, Sweden
| | - Abolghasem Jouyban
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.,School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Breath Analysis: Comparison among Methodological Approaches for Breath Sampling. Molecules 2020; 25:molecules25245823. [PMID: 33321824 PMCID: PMC7763204 DOI: 10.3390/molecules25245823] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 12/04/2020] [Accepted: 12/07/2020] [Indexed: 12/20/2022] Open
Abstract
Despite promising results obtained in the early diagnosis of several pathologies, breath analysis still remains an unused technique in clinical practice due to the lack of breath sampling standardized procedures able to guarantee a good repeatability and comparability of results. The most diffuse on an international scale breath sampling method uses polymeric bags, but, recently, devices named Mistral and ReCIVA, able to directly concentrate volatile organic compounds (VOCs) onto sorbent tubes, have been developed and launched on the market. In order to explore performances of these new automatic devices with respect to sampling in the polymeric bag and to study the differences in VOCs profile when whole or alveolar breath is collected and when pulmonary wash out with clean air is done, a tailored experimental design was developed. Three different breath sampling approaches were compared: (a) whole breath sampling by means of Tedlar bags, (b) the end-tidal breath collection using the Mistral sampler, and (c) the simultaneous collection of the whole and alveolar breath by using the ReCIVA. The obtained results showed that alveolar fraction of breath was relatively less affected by ambient air (AA) contaminants (p-values equal to 0.04 for Mistral and 0.002 for ReCIVA Low) with respect to whole breath (p-values equal to 0.97 for ReCIVA Whole). Compared to Tedlar bags, coherent results were obtained by using Mistral while lower VOCs levels were detected for samples (both breath and AA) collected by ReCIVA, likely due to uncorrected and fluctuating flow rates applied by this device. Finally, the analysis of all data also including data obtained by explorative analysis of the unique lung cancer (LC) breath sample showed that a clean air supply might determine a further confounding factor in breath analysis considering that lung wash-out is species-dependent.
Collapse
|
5
|
Sukul P, Schubert JK, Zanaty K, Trefz P, Sinha A, Kamysek S, Miekisch W. Exhaled breath compositions under varying respiratory rhythms reflects ventilatory variations: translating breathomics towards respiratory medicine. Sci Rep 2020; 10:14109. [PMID: 32839494 PMCID: PMC7445240 DOI: 10.1038/s41598-020-70993-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Accepted: 08/07/2020] [Indexed: 12/12/2022] Open
Abstract
Control of breathing is automatic and its regulation is keen to autonomic functions. Therefore, involuntary and voluntary nervous regulation of breathing affects ventilatory variations, which has profound potential to address expanding challenges in contemporary pulmonology. Nonetheless, the fundamental attributes of the aforementioned phenomena are rarely understood and/or investigated. Implementation of unconventional approach like breathomics may leads to a better comprehension of those complexities in respiratory medicine. We applied breath-resolved spirometry and capnometry, non-invasive hemodynamic monitoring along with continuous trace analysis of exhaled VOCs (volatile organic compounds) by means of real-time mass-spectrometry in 25 young and healthy adult humans to investigate any possible mirroring of instant ventilatory variations by exhaled breath composition, under varying respiratory rhythms. Hemodynamics remained unaffected. Immediate changes in measured breath compositions and corresponding variations occurred when respiratory rhythms were switched between spontaneous (involuntary/unsynchronised) and/or paced (voluntary/synchronised) breathing. Such changes in most abundant, endogenous and bloodborne VOCs were closely related to the minute ventilation and end-tidal CO2 exhalation. Unprecedentedly, while preceded by a paced rhythm, spontaneous rhythms in both independent setups became reproducible with significantly (P-value ≤ 0.005) low intra- and inter-individual variation in measured parameters. We modelled breath-resolved ventilatory variations via alveolar isoprene exhalation, which were independently validated with unequivocal precision. Reproducibility i.e. attained via our method would be reliable for human breath sampling, concerning biomarker research. Thus, we may realize the actual metabolic and pathophysiological expressions beyond the everlasting in vivo physiological noise. Consequently, less pronounced changes are often misinterpreted as disease biomarker in cross-sectional studies. We have also provided novel information beyond conventional spirometry and capnometry. Upon clinical translations, our findings will have immense impact on pulmonology and breathomics as they have revealed a reproducible pattern of ventilatory variations and respiratory homeostasis in endogenous VOC exhalations.
Collapse
Affiliation(s)
- Pritam Sukul
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology and Intensive Care, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany.
| | - Jochen K Schubert
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology and Intensive Care, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| | - Karim Zanaty
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology and Intensive Care, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| | - Phillip Trefz
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology and Intensive Care, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| | - Anupam Sinha
- Institute for Clinical Chemistry and Laboratory Medicine, University Clinic Carl Gustav Carus, Fetscherstr. 74, 01307, Dresden, Germany
| | - Svend Kamysek
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology and Intensive Care, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| | - Wolfram Miekisch
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology and Intensive Care, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| |
Collapse
|
6
|
Tipparaju VV, Xian X, Bridgeman D, Wang D, Tsow F, Forzani E, Tao N. Reliable Breathing Tracking with Wearable Mask Device. IEEE SENSORS JOURNAL 2020; 20:5510-5518. [PMID: 33746622 PMCID: PMC7977629 DOI: 10.1109/jsen.2020.2969635] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Breathing tracking is critical for the assessment of lung functions, exercise physiologies, and energy expenditure. Conventional methods require using a face mask or mouthpiece that is connected to a stationary equipment through a tube, restricting the location, movement, or even the posture. To obtain accurate breathing physiology parameters that represent the true state of the patient during different scenarios, a wearable technology that has less intervention to patient's activities in free-living conditions is highly preferred. Here, we propose a miniaturized, reliable, and wide-dynamic ranged flow sensing technology that is immune to orientation, movement, and noise. As far as we know, this is the first work of introducing a fully integrated mask device focusing on breath tracking in free-living conditions. There are two key challenges for achieving this goal: miniaturized flow sensing and motion-induced artifacts elimination. To address these challenges, we come up with two technical innovations: 1) in hardware wise, we have designed an integrated flow sensing technique based on differential pressure Pneumotach approach and motion sensing; 2) in software wise, we have developed comprehensive algorithms based baseline tracking and orientation and motion compensation. The effectiveness of the proposed technology has been proven by the experiments. Experimental results from simulator and real breath conditions show high correlation (R2 = 0.9994 and 0.9964 respectively) and mean error within 2.5% for Minute Volume (VE), when compared to values computed from reference methods. These results show that the proposed method is accurate and reliable to track the key breath parameters in free-living conditions.
Collapse
Affiliation(s)
- Vishal Varan Tipparaju
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Xiaojun Xian
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Devon Bridgeman
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Di Wang
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Francis Tsow
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Erica Forzani
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Nongjian Tao
- Center for Bioelectronics & Biosensors, the Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| |
Collapse
|
7
|
Tankasala D, Linnes JC. Noninvasive glucose detection in exhaled breath condensate. Transl Res 2019; 213:1-22. [PMID: 31194942 PMCID: PMC6783357 DOI: 10.1016/j.trsl.2019.05.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 05/02/2019] [Accepted: 05/26/2019] [Indexed: 01/04/2023]
Abstract
Two-thirds of patients with diabetes avoid regularly monitoring their blood glucose levels because of the painful and invasive nature of current blood glucose detection. As an alternative to blood sample collection, exhaled breath condensate (EBC) has emerged as a promising noninvasive sample from which to monitor glucose levels. However, this dilute sample matrix requires sensors capable of detecting glucose with high resolution at nanomolar and micromolar concentrations. Recent developments in EBC collection methods and highly sensitive glucose biosensors provide a path toward enabling robust and sensitive glucose detection in EBC. This review addresses current and emerging EBC collection and glucose sensing modalities capable of quantifying glucose in EBC samples. We highlight the opportunities and challenges for development and integration of EBC glucose detection systems that will enable clinically robust and accurate EBC glucose measurements for improved glycemic control.
Collapse
Affiliation(s)
- Divya Tankasala
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana.
| |
Collapse
|
8
|
Azim A, Barber C, Dennison P, Riley J, Howarth P. Exhaled volatile organic compounds in adult asthma: a systematic review. Eur Respir J 2019; 54:13993003.00056-2019. [PMID: 31273044 DOI: 10.1183/13993003.00056-2019] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 06/13/2019] [Indexed: 12/11/2022]
Abstract
The search for biomarkers that can guide precision medicine in asthma, particularly those that can be translated to the clinic, has seen recent interest in exhaled volatile organic compounds (VOCs). Given the number of studies reporting "breathomics" findings and its growing integration in clinical trials, we performed a systematic review of the literature to summarise current evidence and understanding of breathomics technology in asthma.A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses)-oriented systematic search was performed (CRD42017084145) of MEDLINE, Embase and the Cochrane databases to search for any reports that assessed exhaled VOCs in adult asthma patients, using the following terms (asthma AND (volatile organic compounds AND exhaled) OR breathomics).Two authors independently determined the eligibility of 2957 unique records, of which 66 underwent full-text review. Data extraction and risk of bias assessment was performed on the 22 studies deemed to fulfil the search criteria. The studies are described in terms of methodology and the evidence narratively summarised under the following clinical headings: diagnostics, phenotyping, treatment stratification, treatment monitoring and exacerbation prediction/assessment.Our review found that most studies were designed to assess diagnostic potential rather than focus on underlying biology or treatable traits. Results are generally limited by a lack of methodological standardisation and external validation and by insufficiently powered studies, but there is consistency across the literature that exhaled VOCs are sensitive to underlying inflammation. Modern studies are applying robust breath analysis workflows to large multi-centre study designs, which should unlock the full potential of measurement of exhaled volatile organic compounds in airways diseases such as asthma.
Collapse
Affiliation(s)
- Adnan Azim
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK .,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Clair Barber
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK.,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Paddy Dennison
- National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - John Riley
- Galaxy Asthma, GSK, Medicines Research Centre, Stevenage, UK
| | - Peter Howarth
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK.,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| |
Collapse
|
9
|
Using labelled internal standards to improve needle trap micro-extraction technique prior to gas chromatography/mass spectrometry. Talanta 2019; 200:145-155. [DOI: 10.1016/j.talanta.2019.03.046] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 03/08/2019] [Accepted: 03/11/2019] [Indexed: 12/18/2022]
|
10
|
Standardization procedures for real-time breath analysis by secondary electrospray ionization high-resolution mass spectrometry. Anal Bioanal Chem 2019; 411:4883-4898. [PMID: 30989265 PMCID: PMC6611759 DOI: 10.1007/s00216-019-01764-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 02/25/2019] [Accepted: 03/06/2019] [Indexed: 01/27/2023]
Abstract
Despite the attractiveness of breath analysis as a non-invasive means to retrieve relevant metabolic information, its introduction into routine clinical practice remains a challenge. Among all the different analytical techniques available to interrogate exhaled breath, secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS) offers a number of advantages (e.g., real-time, yet wide, metabolome coverage) that makes it ideal for untargeted and targeted studies. However, so far, SESI-HRMS has relied mostly on lab-built prototypes, making it difficult to standardize breath sampling and subsequent analysis, hence preventing further developments such as multi-center clinical studies. To address this issue, we present here a number of new developments. In particular, we have characterized a new SESI interface featuring real-time readout of critical exhalation parameters such as CO2, exhalation flow rate, and exhaled volume. Four healthy subjects provided breath specimens over a period of 1 month to characterize the stability of the SESI-HRMS system. A first assessment of the repeatability of the system using a gas standard revealed a coefficient of variation (CV) of 2.9%. Three classes of aldehydes, namely 4-hydroxy-2-alkenals, 2-alkenals and 4-hydroxy-2,6-alkedienals―hypothesized to be markers of oxidative stress―were chosen as representative metabolites of interest to evaluate the repeatability and reproducibility of this breath analysis analytical platform. Median and interquartile ranges (IQRs) of CVs for CO2, exhalation flow rate, and exhaled volume were 3.2% (1.5%), 3.1% (1.9%), and 5.0% (4.6%), respectively. Despite the high repeatability observed for these parameters, we observed a systematic decay in the signal during repeated measurements for the shorter fatty aldehydes, which eventually reached a steady state after three/four repeated exhalations. In contrast, longer fatty aldehydes showed a steady behavior, independent of the number of repeated exhalation maneuvers. We hypothesize that this highly molecule-specific and individual-independent behavior may be explained by the fact that shorter aldehydes (with higher estimated blood-to-air partition coefficients; approaching 100) mainly get exchanged in the airways of the respiratory system, whereas the longer aldehydes (with smaller estimated blood-to-air partition coefficients; approaching 10) are thought to exchange mostly in the alveoli. Exclusion of the first three exhalations from the analysis led to a median CV (IQR) of 6.7 % (5.5 %) for the said classes of aldehydes. We found that such intra-subject variability is in general much lower than inter-subject variability (median relative differences between subjects 48.2%), suggesting that the system is suitable to capture such differences. No batch effect due to sampling date was observed, overall suggesting that the intra-subject variability measured for these series of aldehydes was biological rather than technical. High correlations found among the series of aldehydes support this notion. Finally, recommendations for breath sampling and analysis for SESI-HRMS users are provided with the aim of harmonizing procedures and improving future inter-laboratory comparisons. Graphical abstract ![]()
Collapse
|
11
|
Marzorati D, Mainardi L, Sedda G, Gasparri R, Spaggiari L, Cerveri P. A review of exhaled breath: a key role in lung cancer diagnosis. J Breath Res 2019; 13:034001. [DOI: 10.1088/1752-7163/ab0684] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
12
|
Güntner AT, Abegg S, Königstein K, Gerber PA, Schmidt-Trucksäss A, Pratsinis SE. Breath Sensors for Health Monitoring. ACS Sens 2019; 4:268-280. [PMID: 30623644 DOI: 10.1021/acssensors.8b00937] [Citation(s) in RCA: 104] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Breath sensors can revolutionize medical diagnostics by on-demand detection and monitoring of health parameters in a noninvasive and personalized fashion. Despite extensive research for more than two decades, however, only a few breath sensors have been translated into clinical practice. Actually, most never even left the scientific laboratories. Here, we describe key challenges that currently impede realization of breath sensors and highlight strategies to overcome them. Specifically, we start with breath marker selection (with emphasis on metabolic and inflammatory markers) and breath sampling. Next, the sensitivity, stability, and selectivity requirements for breath sensors are described. Concepts are elaborated to systematically address these requirements by material design (focusing on chemoresistive metal oxides), orthogonal arrays, and filters. Finally, aspects of portable device integration, user communication, and clinical applicability are discussed.
Collapse
Affiliation(s)
- Andreas T. Güntner
- Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
- Department of Endocrinology, Diabetes, and Clinical Nutrition, University Hospital Zurich, CH-8091 Zurich, Switzerland
| | - Sebastian Abegg
- Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Karsten Königstein
- Division Sports and Exercise Medicine, Department of Sport, Exercise and Health, University of Basel, CH-4052 Basel, Switzerland
| | - Philipp A. Gerber
- Department of Endocrinology, Diabetes, and Clinical Nutrition, University Hospital Zurich, CH-8091 Zurich, Switzerland
| | - Arno Schmidt-Trucksäss
- Division Sports and Exercise Medicine, Department of Sport, Exercise and Health, University of Basel, CH-4052 Basel, Switzerland
| | - Sotiris E. Pratsinis
- Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| |
Collapse
|
13
|
Sensors for Lung Cancer Diagnosis. J Clin Med 2019; 8:jcm8020235. [PMID: 30754727 PMCID: PMC6406777 DOI: 10.3390/jcm8020235] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 02/03/2019] [Accepted: 02/05/2019] [Indexed: 12/12/2022] Open
Abstract
The positive outcome of lung cancer treatment is strongly related to the earliness of the diagnosis. Thus, there is a strong requirement for technologies that could provide an early detection of cancer. The concept of early diagnosis is immediately extended to large population screening, and then, it is strongly related to non-invasiveness and low cost. Sensor technology takes advantage of the microelectronics revolution, and then, it promises to develop devices sufficiently sensitive to detect lung cancer biomarkers. A number of biosensors for the detection of cancer-related proteins have been demonstrated in recent years. At the same time, the interest is growing towards the analysis of volatile metabolites that could be measured directly from the breath. In this paper, a review of the state-of-the-art of biosensors and volatile compound sensors is presented.
Collapse
|
14
|
Davis MD, Fowler SJ, Montpetit AJ. Exhaled breath testing - A tool for the clinician and researcher. Paediatr Respir Rev 2019; 29:37-41. [PMID: 29921519 DOI: 10.1016/j.prrv.2018.05.002] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 05/09/2018] [Indexed: 02/06/2023]
Abstract
Exhaled breath is a robust matrix of biomarkers divided between three fractions - gaseous breath, volatile breath, and breath condensate. Breath is collected non-invasively through bags (for gaseous breath), cold condensation chambers (breath condensate), and adsorbent traps (volatile breath). Due to the incredibly dilute nature of breath matrices, breath biomarker analysis requires precise analytical techniques, highly sensitive technology and often challenges the limit of detection of even the most advanced assays. Interest and advances in breath collection, analysis, and use have increased in recent years largely due to advances in analytical technology. Approved and validated breath tests are available as tools for researchers and clinicians. Novel development is ongoing. This article reviews the current applications for exhaled breath biomarkers.
Collapse
Affiliation(s)
- Michael D Davis
- Division of Pulmonary Medicine, Children's Hospital of Richmond at VCU, Hermes A. Kontos Medical Sciences Building - Room 215, 1217 E. Marshall Street, Richmond, VA 23298, USA.
| | - Stephen J Fowler
- Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, The University of Manchester and Manchester University NHS Foundation Trust, Manchester, UK.
| | - Alison J Montpetit
- VCU Health, Department of Emergency Medicine, Adult Emergency Department, Richmond, VA, USA.
| |
Collapse
|
15
|
Doran SLF, Romano A, Hanna GB. Optimisation of sampling parameters for standardised exhaled breath sampling. J Breath Res 2017; 12:016007. [PMID: 29211685 DOI: 10.1088/1752-7163/aa8a46] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The lack of standardisation of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole versus lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000 ml); and (iii) breath sample flow rate (400, 200, 100 and 50 ml min-1). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' reduces the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to elicit potential biomarkers of gastro-oesophageal cancer, the optimum parameters are 500 mls sample volume of whole breath with a flow rate of 200 ml min-1.
Collapse
Affiliation(s)
- Sophie L F Doran
- Department of Surgery and Cancer, Imperial College, London, United Kingdom
| | | | | |
Collapse
|
16
|
Biagini D, Lomonaco T, Ghimenti S, Bellagambi FG, Onor M, Scali MC, Barletta V, Marzilli M, Salvo P, Trivella MG, Fuoco R, Di Francesco F. Determination of volatile organic compounds in exhaled breath of heart failure patients by needle trap micro-extraction coupled with gas chromatography-tandem mass spectrometry. J Breath Res 2017; 11:047110. [PMID: 29052557 DOI: 10.1088/1752-7163/aa94e7] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The analytical performances of needle trap micro-extraction (NTME) coupled with gas chromatography-tandem mass spectrometry were evaluated by analyzing a mixture of twenty-two representative breath volatile organic compounds (VOCs) belonging to different chemical classes (i.e. hydrocarbons, ketones, aldehydes, aromatics and sulfurs). NTME is an emerging technique that guarantees detection limits in the pptv range by pre-concentrating low volumes of sample, and it is particularly suitable for breath analysis. For most VOCs, detection limits between 20 and 500 pptv were obtained by pre-concentrating 25 ml of a humidified standard gas mixture at a flow rate of 15 ml min-1. For all compounds, inter- and intra-day precisions were always below 15%, confirming the reliability of the method. The procedure was successfully applied to the analysis of exhaled breath samples collected from forty heart failure (HF) patients during their stay in the University Hospital of Pisa. The majority of patients (about 80%) showed a significant decrease of breath acetone levels (a factor of 3 or higher) at discharge compared to admission (acute phase) in correspondence to the improved clinical conditions during hospitalization, thus making this compound eligible as a biomarker of HF exacerbation.
Collapse
Affiliation(s)
- D Biagini
- Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Italy
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Winters BR, Pleil JD, Angrish MM, Stiegel MA, Risby TH, Madden MC. Standardization of the collection of exhaled breath condensate and exhaled breath aerosol using a feedback regulated sampling device. J Breath Res 2017; 11:047107. [PMID: 28894051 DOI: 10.1088/1752-7163/aa8bbc] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Exhaled breath condensate (EBC) and associated exhaled breath aerosols (EBA) are valuable non-invasive biological media used for the quantification of biomarkers. EBC contains exhaled water vapor, soluble gas-phase (polar) organic compounds, ionic species, plus other species including semi- and non-volatile organic compounds, proteins, cell fragments, DNA, dissolved inorganic compounds, ions, and microbiota (bacteria and viruses) dissolved in the co-collected EBA. EBC is collected from subjects who breathe 'normally' through a chilled tube assembly for approximately 10 min and is then harvested into small vials for analysis. Aerosol filters without the chilled tube assembly are also used to separately collect EBA. Unlike typical gas-phase breath samples used for environmental and clinical applications, the constituents of EBC and EBA are not easily characterized by total volume or carbon dioxide (CO2) concentration, because the gas-phase is vented. Furthermore, EBC and associated EBA are greatly affected by breathing protocol, more specifically, depth of inhalation and expelled breath velocity. We have tested a new instrument developed by Loccioni Gruppa Humancare (Ancona, Italy) for implementation of EBC collection from human subjects to assess EBC collection parameters. The instrument is the first EBC collection device that provides instantaneous visual feedback to the subjects to control breathing patterns. In this report we describe the operation of the instrument, and present an overview of performance and analytical applications.
Collapse
Affiliation(s)
- Brett R Winters
- Curriculum in Toxicology, University of North Carolina, Chapel Hill, NC, United States of America
| | | | | | | | | | | |
Collapse
|
18
|
Högman M. Innovative exhaled breath analysis with old breathing manoeuvres-is there a problem or an advantage? J Breath Res 2017; 11:031001. [PMID: 28660856 DOI: 10.1088/1752-7163/aa720b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
As the field of exhaled breath research is expanding, the question that arises is can the old usual method of spirometry be used in all cases? The answer is yes for some analysation methods and definitely not for others: it all depends on the result you are looking for. Exhaled breath condensate collection can be accomplished with silent tidal breathing, but not in the analysation of the amount of exhaled particles, as they become very low during tidal breathing. There are gases that are exhalation flow dependent, e.g. nitric oxide, acetone and ethanol, that require a special breathing manoeuvre with flow control. Physiological changes of the lung, i.e. inhalation to total lung capacity or forced exhalation such as during spirometry, will affect the result of exhaled biomarkers. The standardisation of exhaled breath requires further development, and there are many aspects to consider.
Collapse
Affiliation(s)
- Marieann Högman
- Dept. of Medical Sciences, Respiratory, Allergy & Sleep Research, Uppsala University, Uppsala, Sweden
| |
Collapse
|
19
|
Shokry E, de Oliveira AE, Avelino MAG, de Deus MM, Filho NRA. Earwax: A neglected body secretion or a step ahead in clinical diagnosis? A pilot study. J Proteomics 2017; 159:92-101. [DOI: 10.1016/j.jprot.2017.03.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 02/25/2017] [Accepted: 03/07/2017] [Indexed: 12/16/2022]
|
20
|
Lawal O, Ahmed WM, Nijsen TME, Goodacre R, Fowler SJ. Exhaled breath analysis: a review of 'breath-taking' methods for off-line analysis. Metabolomics 2017; 13:110. [PMID: 28867989 PMCID: PMC5563344 DOI: 10.1007/s11306-017-1241-8] [Citation(s) in RCA: 123] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2017] [Accepted: 07/24/2017] [Indexed: 12/12/2022]
Abstract
BACKGROUND The potential of exhaled breath sampling and analysis has long attracted interest in the areas of medical diagnosis and disease monitoring. This interest is attributed to its non-invasive nature, access to an unlimited sample supply (i.e., breath), and the potential to facilitate a rapid at patient diagnosis. However, progress from laboratory setting to routine clinical practice has been slow. Different methodologies of breath sampling, and the consequent difficulty in comparing and combining data, are considered to be a major contributor to this. To fulfil the potential of breath analysis within clinical and pre-clinical medicine, standardisation of some approaches to breath sampling and analysis will be beneficial. OBJECTIVES The aim of this review is to investigate the heterogeneity of breath sampling methods by performing an in depth bibliometric search to identify the current state of art in the area. In addition, the review will discuss and critique various breath sampling methods for off-line breath analysis. METHODS Literature search was carried out in databases MEDLINE, BIOSIS, EMBASE, INSPEC, COMPENDEX, PQSCITECH, and SCISEARCH using the STN platform which delivers peer-reviewed articles. Keywords searched for include breath, sampling, collection, pre-concentration, volatile. Forward and reverse search was then performed on initially included articles. The breath collection methodologies of all included articles was subsequently reviewed. RESULTS Sampling methods differs between research groups, for example regarding the portion of breath being targeted. Definition of late expiratory breath varies between studies. CONCLUSIONS Breath analysis is an interdisciplinary field of study using clinical, analytical chemistry, data processing, and metabolomics expertise. A move towards standardisation in breath sampling is currently being promoted within the breath research community with a view to harmonising analysis and thereby increasing robustness and inter-laboratory comparisons.
Collapse
Affiliation(s)
- Oluwasola Lawal
- 0000000121662407grid.5379.8Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
- 0000 0004 0398 9387grid.417284.cPhilips Research, Royal Philips B.V., Eindhoven, The Netherlands
- 0000000121662407grid.5379.8School of Chemistry, Manchester Institute of Biotechnology, The University of Manchester, Manchester, UK
| | - Waqar M. Ahmed
- 0000000121662407grid.5379.8Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
- 0000 0004 0398 9387grid.417284.cPhilips Research, Royal Philips B.V., Eindhoven, The Netherlands
- 0000000121662407grid.5379.8School of Chemistry, Manchester Institute of Biotechnology, The University of Manchester, Manchester, UK
| | - Tamara M. E. Nijsen
- 0000 0004 0398 9387grid.417284.cPhilips Research, Royal Philips B.V., Eindhoven, The Netherlands
| | - Royston Goodacre
- 0000000121662407grid.5379.8School of Chemistry, Manchester Institute of Biotechnology, The University of Manchester, Manchester, UK
| | - Stephen J. Fowler
- 0000000121662407grid.5379.8Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
- 0000 0004 0430 9363grid.5465.2Manchester Academic Health Science Centre, The University of Manchester and University Hospital of South Manchester NHS Foundation Trust, Manchester, UK
| |
Collapse
|
21
|
Lomonaco T, Salvo P, Ghimenti S, Biagini D, Bellagambi F, Fuoco R, Di Francesco F. A breath sampling system assessing the influence of respiratory rate on exhaled breath composition. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7618-21. [PMID: 26738056 DOI: 10.1109/embc.2015.7320156] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This work presents a computerized system to monitor mouth pressure, tidal volume, exhaled airflow, respiration rate and end-tidal partial pressure of CO2 during breath collection. The system was used to investigate the effect of different respiratory rates on the volatile organic compounds (VOCs) concentrations in exhaled breath. For this purpose, VOCs with well-defined biochemical pathways and different chemical and physical properties were selected as biomarkers related to metabolism (acetone and isopropyl alcohol), cholesterol synthesis (isoprene) and intestinal microflora activity (ethanol). Mixed breath was collected from a nominally healthy volunteer in resting conditions by filling a Nalophan bag. The subject followed a regimented breathing pattern at different respiratory rates (10, 30 and 50 breaths per minute). Results highlight that ventilation pattern strongly influences the concentration of the selected compounds. The proposed system allows exhaled breath to be collected also in patients showing dyspnea such as in case of chronic heart failure, asthma and pulmonary diseases.
Collapse
|
22
|
Hafez EM, Hamad MA, Fouad M, Abdel-Lateff A. Auto-brewery syndrome: Ethanol pseudo-toxicity in diabetic and hepatic patients. Hum Exp Toxicol 2016; 36:445-450. [PMID: 27492480 DOI: 10.1177/0960327116661400] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Endogenous alcohol has been applied for spontaneous ethanol production via different metabolic pathways of the human body. Auto-brewery syndrome describes the patients with alcohol intoxication after ingesting carbohydrate-rich meals. The main objective of this study is to investigate the effect of diabetes mellitus (DM), liver cirrhosis (LC) and presence of both (DM and LC) on blood alcohol concentration (BAC) especially after carbohydrate ingestion. BAC has been measured by headspace gas chromatography-mass spectrometry in three groups of humans namely control, DM, LC and both (DM and LC) groups. The results showed that BAC in control group was 0.01-.3 mg/dL with mean 0.3 ± 0.41 mg/dL. In patients with DM, BAC is significantly higher than that of control group 4.85 ± 3.96 mg/dL. In patients with LC, BAC was 3.45 ± 2.65 mg/dL. In patients with both DM and LC, BAC increases to reach 10.88 ± 5.36 mg/dL. Endogenous ethanol production appears to increase in DM and LC. Also, it increased much more in patients with both diseases, but it did not reach toxic levels. On comparing BAC and blood glucose level in each group, all groups show insignificant correlations ( p > 0.05).
Collapse
Affiliation(s)
- E M Hafez
- 1 Department of Forensic Medicine and Clinical Toxicology, Faculty of Medicine, Minia University, Minia, Egypt
| | - M A Hamad
- 1 Department of Forensic Medicine and Clinical Toxicology, Faculty of Medicine, Minia University, Minia, Egypt
| | - M Fouad
- 2 Department of Tropical medicine, Faculty of Medicine, Minia University, Minia, Egypt
| | - A Abdel-Lateff
- 3 Department of Pharmacognosy, Faculty of Pharmacy, Minia University, Minia, Egypt.,4 Department of Natural Products and Alternative Medicine, Faculty of Pharmacy, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
23
|
Cheng M, Galbally IE, Molloy SB, Selleck PW, Keywood MD, Lawson SJ, Powell JC, Gillett RW, Dunne E. Factors controlling volatile organic compounds in dwellings in Melbourne, Australia. INDOOR AIR 2016; 26:219-230. [PMID: 25788118 DOI: 10.1111/ina.12201] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Accepted: 03/13/2015] [Indexed: 06/04/2023]
Abstract
This study characterized indoor volatile organic compounds (VOCs) and investigated the effects of the dwelling characteristics, building materials, occupant activities, and environmental conditions on indoor VOC concentrations in 40 dwellings located in Melbourne, Australia, in 2008 and 2009. A total of 97 VOCs were identified. Nine VOCs, n-butane, 2-methylbutane, toluene, formaldehyde, acetaldehyde, d-limonene, ethanol, 2-propanol, and acetic acid, accounted for 68% of the sum of all VOCs. The median indoor concentrations of all VOCs were greater than those measured outdoors. The occupant density was positively associated with indoor VOC concentrations via occupant activities, including respiration and combustion. Terpenes were associated with the use of household cleaning and laundry products. A petroleum-like indoor VOC signature of alkanes and aromatics was associated with the proximity of major roads. The indoor VOC concentrations were negatively correlated (P < 0.05) with ventilation. Levels of VOCs in these Australian dwellings were lower than those from previous studies in North America and Europe, probably due to a combination of an ongoing temporal decrease in indoor VOC concentrations and the leakier nature of Australian dwellings.
Collapse
Affiliation(s)
- M Cheng
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - I E Galbally
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - S B Molloy
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - P W Selleck
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - M D Keywood
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - S J Lawson
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - J C Powell
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - R W Gillett
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| | - E Dunne
- CSIRO Oceans and Atmosphere Flagship, Aspendale, Vic., Australia
| |
Collapse
|
24
|
Gasparri R, Santonico M, Valentini C, Sedda G, Borri A, Petrella F, Maisonneuve P, Pennazza G, D'Amico A, Di Natale C, Paolesse R, Spaggiari L. Volatile signature for the early diagnosis of lung cancer. J Breath Res 2016; 10:016007. [PMID: 26857451 DOI: 10.1088/1752-7155/10/1/016007] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Exhaled breath contains hundreds of volatile organic compounds (VOCs). Several independent researchers point out that the breath of lung cancer patients shows a characteristic VOC-profile which can be considered as lung cancer signature and, thus, used for diagnosis. In this regard, the analysis of exhaled breath with gas sensor arrays is a potential non-invasive, relatively low-cost and easy technique for the early detection of lung cancer. This clinical study evaluated the gas sensor array response for the identification of the exhaled breath of lung cancer patients. This study involved 146 individuals: 70 with lung cancer confirmed by computerized tomography (CT) or positron emission tomography-(PET) imaging techniques and histology (biopsy) or with clinical suspect of lung cancer and 76 healthy controls. Their exhaled breath was measured with a gas sensor array composed of a matrix of eight quartz microbalances (QMBs), each functionalized with a different metalloporphyrin. The instrument produces, for each analyzed sample, a vector of signals encoding the breath (breathprint). Breathprints were analyzed with multivariate analysis in order to correlate the sensor signals to the disease. Breathprints of the lung cancer patients were differentiated from those of the healthy controls with a sensitivity of 81% and specificity of 91%. Similar values were obtained in patients with and without metabolic comorbidities, such as diabetes, obesity and dyslipidemia (sensitivity 85%, specificity 88% and sensitivity 76%, specificity 94%, respectively). The device showed a large sensitivity to lung cancer at stage I with respect to stage II/III/IV (92% and 58% respectively). The sensitivity for stage I did not change for patients with or without metabolic comorbidities (90%, 94%, respectively). Results show that this electronic nose can discriminate the exhaled breath of the lung cancer patients from those of the healthy controls. Moreover, the largest sensitivity is observed for the subgroup of patients with a lung cancer at stage I.
Collapse
Affiliation(s)
- Roberto Gasparri
- Division of Thoracic Surgery, European Institute of Oncology, Milan, Italy
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Szabó A, Unterkofler K, Mochalski P, Jandacka M, Ruzsanyi V, Szabó G, Mohácsi Á, Teschl S, Teschl G, King J. Modeling of breath methane concentration profiles during exercise on an ergometer. J Breath Res 2016; 10:017105. [PMID: 26828421 DOI: 10.1088/1752-7155/10/1/017105] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We develop a simple three compartment model based on mass balance equations which quantitatively describes the dynamics of breath methane concentration profiles during exercise on an ergometer. With the help of this model it is possible to estimate the endogenous production rate of methane in the large intestine by measuring breath gas concentrations of methane.
Collapse
Affiliation(s)
- Anna Szabó
- MTA-SZTE Research Group on Photoacoustic Spectroscopy, Dóm tér 9, 6720 Szeged, Hungary. Breath Research Institute, University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Spacek LA, Mudalel M, Tittel F, Risby TH, Solga SF. Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults. J Breath Res 2015; 9:047109. [PMID: 26658550 DOI: 10.1088/1752-7155/9/4/047109] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μmol L(-1) (interquartile range (IQR), 3-18) versus 46 μmol L(-1) (IQR, 23-66) for cirrhotic participants. Median breath ammonia was 379 pmol mL(-1) CO2 (IQR, 265-765) for healthy versus 350 pmol mL(-1) CO2 (IQR, 180-1013) for cirrhotic participants. CV was 17 ± 6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia.
Collapse
Affiliation(s)
- Lisa A Spacek
- School of Medicine, Johns Hopkins University, Baltimore, MD 21218, USA
| | | | | | | | | |
Collapse
|
27
|
Ghimenti S, Lomonaco T, Bellagambi FG, Tabucchi S, Onor M, Trivella MG, Ceccarini A, Fuoco R, Di Francesco F. Comparison of sampling bags for the analysis of volatile organic compounds in breath. J Breath Res 2015; 9:047110. [DOI: 10.1088/1752-7155/9/4/047110] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
28
|
Sukul P, Trefz P, Kamysek S, Schubert JK, Miekisch W. Instant effects of changing body positions on compositions of exhaled breath. J Breath Res 2015; 9:047105. [PMID: 26582820 DOI: 10.1088/1752-7155/9/4/047105] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Concentrations of exhaled volatile organic compounds (VOCs) may depend not only on biochemical or pathologic processes but also on physiological parameters. As breath sampling may be done in different body positions, effects of the sampling position on exhaled VOC concentrations were investigated by means of real-time mass spectrometry. Breaths from 15 healthy volunteers were analyzed in real-time by PTR-ToF-MS-8000 during paced breathing (12/min) in a continuous side-stream mode. We applied two series of body positions (setup 1: sitting, standing, supine, and sitting; setup 2: supine, left lateral, right lateral, prone, and supine). Each position was held for 2 min. Breath VOCs were quantified in inspired and alveolar air by means of a custom-made algorithm. Parallel monitoring of hemodynamics and capnometry was performed noninvasively. In setup 1, when compared to the initial sitting position, normalized mean concentrations of isoprene, furan, and acetonitrile decreased by 24%, 26%, and 9%, respectively, during standing and increased by 63%, 36%, and 10% during lying mirroring time profiles of stroke volume and pET-CO2. In contrast, acetone and H2S concentrations remained almost constant. In setup 2, when compared to the initial supine position, mean alveolar concentrations of isoprene and furan increased significantly up to 29% and 16%, respectively, when position was changed from lying on the right side to the prone position. As cardiac output and stroke volume decreased at that time, the reasons for the observed concentrations changes have to be linked to the ventilation/perfusion ratio or compartmental distribution rather than to perfusion alone. During final postures, all VOC concentrations, hemodynamics, and pET-CO2 returned to baseline. Exhaled blood-borne VOC profiles changed due to body postures. Changes depended on cardiac stroke volume, origin, compartmental distribution and physico-chemical properties of the substances. Patients' positions and cardiac output have to be controlled when concentrations of breath VOCs are to be interpreted in terms of biomarkers.
Collapse
Affiliation(s)
- Pritam Sukul
- Department of Anesthesiology and Intensive Care Medicine, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), University Medicine Rostock, Schillingallee 35, D-18057 Rostock, Germany
| | | | | | | | | |
Collapse
|
29
|
The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs. Sci Rep 2015; 5:16491. [PMID: 26559776 PMCID: PMC4642313 DOI: 10.1038/srep16491] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Accepted: 10/12/2015] [Indexed: 11/23/2022] Open
Abstract
Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.
Collapse
|
30
|
Righettoni M, Ragnoni A, Güntner AT, Loccioni C, Pratsinis SE, Risby TH. Monitoring breath markers under controlled conditions. J Breath Res 2015; 9:047101. [DOI: 10.1088/1752-7155/9/4/047101] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
31
|
Breath carbonyl compounds as biomarkers of lung cancer. Lung Cancer 2015; 90:92-7. [PMID: 26233567 DOI: 10.1016/j.lungcan.2015.07.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Revised: 06/15/2015] [Accepted: 07/12/2015] [Indexed: 11/22/2022]
Abstract
OBJECTIVE Lung cancer dysregulations impart oxidative stress which results in important metabolic products in the form of volatile organic compounds (VOCs) in exhaled breath. The objective of this work is to use statistical classification models to determine specific carbonyl VOCs in exhaled breath as biomarkers for detection of lung cancer. MATERIALS AND METHODS Exhaled breath samples from 85 patients with untreated lung cancer, 34 patients with benign pulmonary nodules and 85 healthy controls were collected. Carbonyl compounds in exhaled breath were captured by silicon microreactors and analyzed by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). The concentrations of carbonyl compounds were analyzed using a variety of statistical classification models to determine which compounds best differentiated between the patient sub-populations. Predictive accuracy of each of the models was assessed on a separate test data set. RESULTS Six carbonyl compounds (C(4)H(8)O, C(5)H(10)O, C(2)H(4)O(2), C(4)H(8)O(2), C(6)H(10)O(2), C(9)H(16)O(2)) had significantly elevated concentrations in lung cancer patients vs. CONTROLS A model based on counting the number of elevated compounds out of these six achieved an overall classification accuracy on the test data of 97% (95% CI 92%-100%), 95% (95% CI 88%-100%), and 89% (95% CI 79%-99%) for classifying lung cancer patients vs. non-smokers, current smokers, and patients with benign nodules, respectively. These results were comparable to benchmarking based on established statistical and machine-learning methods. The sensitivity in each case was 96% or higher, with specificity ranging from 64% for benign nodule patients to 86% for smokers and 100% for non-smokers. CONCLUSION A model based on elevated levels of the six carbonyl VOCs effectively discriminates lung cancer patients from healthy controls as well as patients with benign pulmonary nodules.
Collapse
|
32
|
Mirowsky J, Gordon T. Noninvasive effects measurements for air pollution human studies: methods, analysis, and implications. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2015; 25:354-80. [PMID: 25605444 PMCID: PMC6659729 DOI: 10.1038/jes.2014.93] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Revised: 09/26/2014] [Accepted: 11/05/2014] [Indexed: 05/09/2023]
Abstract
Human exposure studies, compared with cell and animal models, are heavily relied upon to study the associations between health effects in humans and air pollutant inhalation. Human studies vary in exposure methodology, with some work conducted in controlled settings, whereas other studies are conducted in ambient environments. Human studies can also vary in the health metrics explored, as there exists a myriad of health effect end points commonly measured. In this review, we compiled mini reviews of the most commonly used noninvasive health effect end points that are suitable for panel studies of air pollution, broken into cardiovascular end points, respiratory end points, and biomarkers of effect from biological specimens. Pertinent information regarding each health end point and the suggested methods for mobile collection in the field are assessed. In addition, the clinical implications for each health end point are summarized, along with the factors identified that can modify each measurement. Finally, the important research findings regarding each health end point and air pollutant exposures were reviewed. It appeared that most of the adverse health effects end points explored were found to positively correlate with pollutant levels, although differences in study design, pollutants measured, and study population were found to influence the magnitude of these effects. Thus, this review is intended to act as a guide for researchers interested in conducting human exposure studies of air pollutants while in the field, although there can be a wider application for using these end points in many epidemiological study designs.
Collapse
Affiliation(s)
- Jaime Mirowsky
- Department of Environmental Medicine, New York University School of Medicine, Nelson Institute of Environmental Medicine, Tuxedo, New York, USA
| | - Terry Gordon
- Department of Environmental Medicine, New York University School of Medicine, Nelson Institute of Environmental Medicine, Tuxedo, New York, USA
| |
Collapse
|
33
|
Spacek LA, Mudalel ML, Lewicki R, Tittel FK, Risby TH, Stoltzfus J, Munier JJ, Solga SF. Breath ammonia and ethanol increase in response to a high protein challenge. Biomarkers 2015; 20:149-56. [PMID: 26043432 DOI: 10.3109/1354750x.2015.1040840] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Quantifying changes in ammonia and ethanol in blood and body fluid assays in response to food is cumbersome. We used breath analysis of ammonia, ethanol, hydrogen (an accepted standard of gut transit) and acetone to investigate gastrointestinal physiology. In 30 healthy participants, we measured each metabolite serially over 6 h in control and high protein trials. Two-way repeated measures ANOVA compared treatment (control versus intervention), change from baseline to maximum and interaction of treatment and time change. Interaction was significant for ammonia (p < 0.0001) and hydrogen (p < 0.0001). We describe the dynamic measurement of multiple metabolites in response to an oral challenge.
Collapse
Affiliation(s)
- Lisa A Spacek
- Department of Medicine, School of Medicine, Johns Hopkins University , Baltimore, MD , USA
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Salvo P, Ferrari C, Persia R, Ghimenti S, Lomonaco T, Bellagambi F, Di Francesco F. A dual mode breath sampler for the collection of the end-tidal and dead space fractions. Med Eng Phys 2015; 37:539-44. [PMID: 25922294 DOI: 10.1016/j.medengphy.2015.03.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 03/17/2015] [Accepted: 03/24/2015] [Indexed: 11/16/2022]
Abstract
This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties.
Collapse
Affiliation(s)
- P Salvo
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy
| | - C Ferrari
- National Research Council of Italy, C.N.R., Istituto Nazionale di Ottica, (INO) - UOS Pisa, Via G. Moruzzi 1, 56124 Pisa, Italy
| | - R Persia
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy
| | - S Ghimenti
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy
| | - T Lomonaco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy
| | - F Bellagambi
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy
| | - F Di Francesco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy.
| |
Collapse
|
35
|
Szabó A, Ruzsanyi V, Unterkofler K, Mohácsi Á, Tuboly E, Boros M, Szabó G, Hinterhuber H, Amann A. Exhaled methane concentration profiles during exercise on an ergometer. J Breath Res 2015; 9:016009. [PMID: 25749807 DOI: 10.1088/1752-7155/9/1/016009] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Exhaled methane concentration measurements are extensively used in medical investigation of certain gastrointestinal conditions. However, the dynamics of endogenous methane release is largely unknown. Breath methane profiles during ergometer tests were measured by means of a photoacoustic spectroscopy based sensor. Five methane-producing volunteers (with exhaled methane level being at least 1 ppm higher than room air) were measured. The experimental protocol consisted of 5 min rest--15 min pedalling (at a workload of 75 W)--5 min rest. In addition, hemodynamic and respiratory parameters were determined and compared to the estimated alveolar methane concentration. The alveolar breath methane level decreased considerably, by a factor of 3-4 within 1.5 min, while the estimated ventilation-perfusion ratio increased by a factor of 2-3. Mean pre-exercise and exercise methane concentrations were 11.4 ppm (SD:7.3) and 2.8 ppm (SD:1.9), respectively. The changes can be described by the high sensitivity of exhaled methane to ventilation-perfusion ratio and are in line with the Farhi equation.
Collapse
Affiliation(s)
- A Szabó
- MTA-SZTE Research Group on Photoacoustic Spectroscopy, Dóm tér 9, 6720 Szeged, Hungary. Department of Optics and Quantum Electronics, Faculty of Science and Informatics, University of Szeged, Dóm tér 9, 6720 Szeged, Hungary
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Solga SF, Mudalel M, Spacek LA, Lewicki R, Tittel FK, Loccioni C, Russo A, Ragnoni A, Risby TH. Changes in the concentration of breath ammonia in response to exercise: a preliminary investigation. J Breath Res 2014; 8:037103. [PMID: 25189784 DOI: 10.1088/1752-7155/8/3/037103] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Breath ammonia has proven to be a difficult compound to measure accurately. The goal of this study was to evaluate the effects that the physiological intervention, exercise, had on the levels of breath ammonia. The effects of vigorous exercise (4000 m indoor row) in 13 participants were studied and increases in breath ammonia were observed in all participants. Mean pre-exercise concentrations of ammonia were 670 pmol ml(-1) CO2 (SD, 446) and these concentrations increased to post-exercise maxima of 1499 pmol ml(-1) CO2 (SD, 730), p < 0.0001. The mean increase in ammonia concentrations from pre-exercise to maximum achieved in conditioned (1362 pmol ml(-1) CO2) versus non-conditioned rowers (591 pmol ml(-1) CO2) were found to be statistically different, p = 0.029. Taken together, these results demonstrate our ability to repeatedly measure the influence of exercise on the concentration of breath ammonia.
Collapse
Affiliation(s)
- Steven F Solga
- Solga Gastroenterology, Bethlehem, PA, USA. St. Luke's University Hospital/Temple School of Medicine, Bethlehem, PA, USA. School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Herbig J, Beauchamp J. Towards standardization in the analysis of breath gas volatiles. J Breath Res 2014; 8:037101. [DOI: 10.1088/1752-7155/8/3/037101] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Rudel RA, Ackerman JM, Attfield KR, Brody JG. New exposure biomarkers as tools for breast cancer epidemiology, biomonitoring, and prevention: a systematic approach based on animal evidence. ENVIRONMENTAL HEALTH PERSPECTIVES 2014; 122:881-95. [PMID: 24818537 PMCID: PMC4154213 DOI: 10.1289/ehp.1307455] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Accepted: 04/29/2014] [Indexed: 05/19/2023]
Abstract
BACKGROUND Exposure to chemicals that cause rodent mammary gland tumors is common, but few studies have evaluated potential breast cancer risks of these chemicals in humans. OBJECTIVE The goal of this review was to identify and bring together the needed tools to facilitate the measurement of biomarkers of exposure to potential breast carcinogens in breast cancer studies and biomonitoring. METHODS We conducted a structured literature search to identify measurement methods for exposure biomarkers for 102 chemicals that cause rodent mammary tumors. To evaluate concordance, we compared human and animal evidence for agents identified as plausibly linked to breast cancer in major reviews. To facilitate future application of exposure biomarkers, we compiled information about relevant cohort studies. RESULTS Exposure biomarkers have been developed for nearly three-quarters of these rodent mammary carcinogens. Analytical methods have been published for 73 of the chemicals. Some of the remaining chemicals could be measured using modified versions of existing methods for related chemicals. In humans, biomarkers of exposure have been measured for 62 chemicals, and for 45 in a nonoccupationally exposed population. The Centers for Disease Control and Prevention has measured 23 in the U.S. population. Seventy-five of the rodent mammary carcinogens fall into 17 groups, based on exposure potential, carcinogenicity, and structural similarity. Carcinogenicity in humans and rodents is generally consistent, although comparisons are limited because few agents have been studied in humans. We identified 44 cohort studies, with a total of > 3.5 million women enrolled, that have recorded breast cancer incidence and stored biological samples. CONCLUSIONS Exposure measurement methods and cohort study resources are available to expand biomonitoring and epidemiology related to breast cancer etiology and prevention.
Collapse
|
39
|
Lourenço C, Turner C. Breath analysis in disease diagnosis: methodological considerations and applications. Metabolites 2014; 4:465-98. [PMID: 24957037 PMCID: PMC4101517 DOI: 10.3390/metabo4020465] [Citation(s) in RCA: 140] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 06/02/2014] [Accepted: 06/09/2014] [Indexed: 02/07/2023] Open
Abstract
Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.
Collapse
Affiliation(s)
- Célia Lourenço
- Department of Life, Health & Chemical Sciences, Chemistry and Analytical Sciences, The Open University, Walton Hall, Milton Keynes, MK7 6AA, UK.
| | - Claire Turner
- Department of Life, Health & Chemical Sciences, Chemistry and Analytical Sciences, The Open University, Walton Hall, Milton Keynes, MK7 6AA, UK.
| |
Collapse
|
40
|
Amann A, Costello BDL, Miekisch W, Schubert J, Buszewski B, Pleil J, Ratcliffe N, Risby T. The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva. J Breath Res 2014; 8:034001. [PMID: 24946087 DOI: 10.1088/1752-7155/8/3/034001] [Citation(s) in RCA: 358] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Breath analysis is a young field of research with its roots in antiquity. Antoine Lavoisier discovered carbon dioxide in exhaled breath during the period 1777-1783, Wilhelm (Vilém) Petters discovered acetone in breath in 1857 and Johannes Müller reported the first quantitative measurements of acetone in 1898. A recent review reported 1765 volatile compounds appearing in exhaled breath, skin emanations, urine, saliva, human breast milk, blood and feces. For a large number of compounds, real-time analysis of exhaled breath or skin emanations has been performed, e.g., during exertion of effort on a stationary bicycle or during sleep. Volatile compounds in exhaled breath, which record historical exposure, are called the 'exposome'. Changes in biogenic volatile organic compound concentrations can be used to mirror metabolic or (patho)physiological processes in the whole body or blood concentrations of drugs (e.g. propofol) in clinical settings-even during artificial ventilation or during surgery. Also compounds released by bacterial strains like Pseudomonas aeruginosa or Streptococcus pneumonia could be very interesting. Methyl methacrylate (CAS 80-62-6), for example, was observed in the headspace of Streptococcus pneumonia in concentrations up to 1420 ppb. Fecal volatiles have been implicated in differentiating certain infectious bowel diseases such as Clostridium difficile, Campylobacter, Salmonella and Cholera. They have also been used to differentiate other non-infectious conditions such as irritable bowel syndrome and inflammatory bowel disease. In addition, alterations in urine volatiles have been used to detect urinary tract infections, bladder, prostate and other cancers. Peroxidation of lipids and other biomolecules by reactive oxygen species produce volatile compounds like ethane and 1-pentane. Noninvasive detection and therapeutic monitoring of oxidative stress would be highly desirable in autoimmunological, neurological, inflammatory diseases and cancer, but also during surgery and in intensive care units. The investigation of cell cultures opens up new possibilities for elucidation of the biochemical background of volatile compounds. In future studies, combined investigations of a particular compound with regard to human matrices such as breath, urine, saliva and cell culture investigations will lead to novel scientific progress in the field.
Collapse
Affiliation(s)
- Anton Amann
- Univ-Clinic for Anesthesia and Intensive Care, Innsbruck Medical University, Anichstr, 35, A-6020 Innsbruck, Austria. Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Filipiak W, Filipiak A, Sponring A, Schmid T, Zelger B, Ager C, Klodzinska E, Denz H, Pizzini A, Lucciarini P, Jamnig H, Troppmair J, Amann A. Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers. J Breath Res 2014; 8:027111. [PMID: 24862102 DOI: 10.1088/1752-7155/8/2/027111] [Citation(s) in RCA: 104] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Breath analysis for the purpose of non-invasive diagnosis of lung cancer has yielded numerous candidate compounds with still questionable clinical relevance. To arrive at suitable volatile organic compounds our approach combined the analysis of different sources: isolated tumor samples compared to healthy lung tissues, and exhaled breath from lung cancer patients and healthy controls. Candidate compounds were further compared to substances previously identified in the comparison of transformed and normal lung epithelial cell lines. For human studies, a breath sampling device was developed enabling automated and CO2-controlled collection of the end-tidal air. All samples were first preconcentrated on multibed sorption tubes and analyzed with gas chromatography mass spectrometry (GC-MS). Significantly (p < 0.05) higher concentrations in all three types of cancer samples studied were observed for ethanol and n-octane. Additional metabolites (inter alia 2-methylpentane, n-hexane) significantly released by lung cancer cells were observed at higher levels in cancer lung tissues and breath samples (compared to respective healthy controls) with statistical significance (p < 0.05) only in breath samples. The results obtained confirmed the cancer-related origin of volatile metabolites, e.g. ethanol and octane that were both detected at significantly (p < 0.05) elevated concentrations in all three kinds of cancer samples studied. This work is an important step towards identification of volatile breath markers of lung cancer through the demonstration of cancer-related origin of certain volatile metabolites.
Collapse
Affiliation(s)
- Wojciech Filipiak
- Breath Research Institute of the University of Innsbruck, A-6850 Dornbirn, Austria. Univ.-Clinic for Anesthesia and Intensive Care, Innsbruck Medical University, A-6020 Innsbruck, Austria
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Chen W, Metsälä M, Vaittinen O, Halonen L. Hydrogen cyanide in the headspace of oral fluid and in mouth-exhaled breath. J Breath Res 2014; 8:027108. [DOI: 10.1088/1752-7155/8/2/027108] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
43
|
Maurer F, Wolf A, Fink T, Rittershofer B, Heim N, Volk T, Baumbach JI, Kreuer S. Wash-out of ambient air contaminations for breath measurements. J Breath Res 2014; 8:027107. [DOI: 10.1088/1752-7155/8/2/027107] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
44
|
Volatile organic compounds analyzed by gas chromatography-deep ultraviolet spectroscopy. ACTA ACUST UNITED AC 2014. [DOI: 10.1016/j.arthe.2013.12.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
45
|
Amann A, Corradi M, Mazzone P, Mutti A. Lung cancer biomarkers in exhaled breath. Expert Rev Mol Diagn 2014; 11:207-17. [DOI: 10.1586/erm.10.112] [Citation(s) in RCA: 131] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
46
|
Pleil JD, Sobus JR, Stiegel MA, Hu D, Oliver KD, Olenick C, Strynar M, Clark M, Madden MC, Funk WE. Estimating common parameters of lognormally distributed environmental and biomonitoring data: harmonizing disparate statistics from publications. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART B, CRITICAL REVIEWS 2014; 17:341-68. [PMID: 25333994 DOI: 10.1080/10937404.2014.956854] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The progression of science is driven by the accumulation of knowledge and builds upon published work of others. Another important feature is to place current results into the context of previous observations. The published literature, however, often does not provide sufficient direct information for the reader to interpret the results beyond the scope of that particular article. Authors tend to provide only summary statistics in various forms, such as means and standard deviations, median and range, quartiles, 95% confidence intervals, and so on, rather than providing measurement data. Second, essentially all environmental and biomonitoring measurements have an underlying lognormal distribution, so certain published statistical characterizations may be inappropriate for comparisons. The aim of this study was to review and develop direct conversions of different descriptions of data into a standard format comprised of the geometric mean (GM) and the geometric standard deviation (GSD) and then demonstrate how, under the assumption of lognormal distribution, these parameters are used to answer questions of confidence intervals, exceedance levels, and statistical differences among distributions. A wide variety of real-world measurement data sets was reviewed, and it was demonstrated that these data sets are indeed of lognormal character, thus making them amenable to these methods. Potential errors incurred from making retrospective estimates from disparate summary statistics are described. In addition to providing tools to interpret "other people's data," this review should also be seen as a cautionary tale for publishing one's own data to make it as useful as possible for other researchers.
Collapse
Affiliation(s)
- Joachim D Pleil
- a Human Exposure and Atmospheric Science Division, NERL/ORD , U.S. Environmental Protection Agency , Research Triangle Park , North Carolina , USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Das MK, Bishwal SC, Das A, Dabral D, Varshney A, Badireddy VK, Nanda R. Investigation of Gender-Specific Exhaled Breath Volatome in Humans by GCxGC-TOF-MS. Anal Chem 2013; 86:1229-37. [DOI: 10.1021/ac403541a] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Mrinal Kumar Das
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| | - Subasa Chandra Bishwal
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| | - Aleena Das
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| | - Deepti Dabral
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| | - Ankur Varshney
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| | - Vinod Kumar Badireddy
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| | - Ranjan Nanda
- Immunology
Group, International Centre
for Genetic Engineering and Biotechnology (ICGEB), New Delhi, India
| |
Collapse
|
48
|
Lung Cancer Screening: Adjuncts and Alternatives to Low-Dose CT Scans. CURRENT SURGERY REPORTS 2013. [DOI: 10.1007/s40137-013-0032-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
49
|
Amal H, Leja M, Broza YY, Tisch U, Funka K, Liepniece-Karele I, Skapars R, Xu ZQ, Liu H, Haick H. Geographical variation in the exhaled volatile organic compounds. J Breath Res 2013; 7:047102. [PMID: 24184568 DOI: 10.1088/1752-7155/7/4/047102] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Breath-gas analysis has demonstrated that concentration profiles of volatile organic compounds (VOCs) could be used for detecting a variety of diseases, among them gastric cancer (GC) and peptic ulcer disease (PUD). Here, we explore how geographical variation affects the disease-specific changes in the chemical composition of breath samples, as compared to control states (less severe gastric conditions). Alveolar exhaled breath samples from 260 patients were collected at two remotely different geographic locations (China and Latvia), following similar breath-collection protocols. Each cohort included 130 patients that were matched in terms of diagnosis (37 GC/32 PUD/61 controls), average age, gender ratio and smoking habits. Helicobacter Pylori infection, which is a major cause for GC and PUD, was found in part of the patients, as well as in part of the controls, at both locations. The breath samples were analyzed by gas chromatography/mass spectrometry, using the same equipment and protocol-of-experiment. We observed similar characteristic differences in the chemical composition of the breath samples between the study groups at the two locations, even though the exact composition of the breath samples differed. Both in China and Latvia, the GC patients and controls could be distinguished by differences in the average levels of 6-methyl-5-hepten-2-one; PUD patients were distinguished from controls by the levels of aromatic compounds and alcohols; GC and PUD patients could not be distinguished at either site. This pilot study indicates the limitations of chemical breath-gas analysis alone for identifying gastric diseases based on the concentration profiles of separate VOCs in international patient cohorts. We assume that these limitations would apply to other diseases as well. The presented data could potentially be useful for developing an alternative, universally applicable diagnostic method that relies on the detection of changes in the collective patterns of the disease-specific classes of exhaled VOCs.
Collapse
Affiliation(s)
- Haitham Amal
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa 3200003, Israel
| | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Bos LDJ, van Walree IC, Kolk AHJ, Janssen HG, Sterk PJ, Schultz MJ. Alterations in exhaled breath metabolite-mixtures in two rat models of lipopolysaccharide-induced lung injury. J Appl Physiol (1985) 2013; 115:1487-95. [PMID: 23908314 DOI: 10.1152/japplphysiol.00685.2013] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Exhaled breath contains information on systemic and pulmonary metabolism, which may provide a monitoring tool for the development of lung injury. We aimed to determine the effect of intravenous (iv) and intratracheal (IT) lipopolysaccharide (LPS) challenge on the exhaled mixture of volatile metabolites and to assess the similarities between these two models. Male adult Sprague-Dawley rats were anesthetized, tracheotomized, and ventilated for 6 h. Lung injury was induced by iv or IT administration of LPS. Exhaled breath was monitored continuously using an electronic nose (eNose), and hourly using gas chromatography and mass spectrometry (GC-MS). GC-MS analysis identified 34 and 14 potential biological markers for lung injury in the iv and IT LPS models, respectively. These volatile biomarkers could be used to discriminate between LPS-challenged rats and control animals within 1 h after LPS administration. Electronic nose analysis resulted in a good separation 3 h after the LPS challenge. Hexanal, pentadecane and 6,10-dimethyl-5,9-undecadien-2-one concentrations decreased after both iv and IT LPS administration. Nonanoic acid was found in a higher concentration in exhaled breath after LPS inoculation into the trachea but in a lower concentration after iv infusion. LPS-induced lung injury rapidly changes exhaled breath metabolite mixtures in two animal models of lung injury. Changes partly overlap between an iv and an IT LPS challenge. This warrants testing the diagnostic accuracy of exhaled breath analysis for acute respiratory distress syndrome in clinical trials, possibly focusing on biological markers described in this study.
Collapse
Affiliation(s)
- Lieuwe D J Bos
- Department of Intensive Care, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|