1
|
Pulsed field ablation: A promising approach for ventricular tachycardia ablation. Int J Cardiol 2024; 407:131985. [PMID: 38513736 DOI: 10.1016/j.ijcard.2024.131985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/15/2024] [Accepted: 03/17/2024] [Indexed: 03/23/2024]
Abstract
Radiofrequency ablation (RFA) has been a central therapeutic strategy for ventricular tachycardia (VT). However, concerns about its long-term effectiveness and complications have arisen. Pulsed field ablation (PFA), characterized by its nonthermal, highly tissue-selective ablation technique, has emerged as a promising alternative. This comprehensive review delves into the potential advantages and opportunities presented by PFA in the realm of VT, drawing insights from both animal experimentation and clinical case studies. PFA shows promise in generating superior lesions within scarred myocardial tissue, and its inherent repetition dependency holds the potential to enhance therapeutic outcomes. Clinical cases underscore the promise of PFA for VT ablation. Despite its promising applications, challenges such as catheter maneuverability and proarrhythmic effects require further investigation. Large-scale, long-term studies are essential to establish the suitability of PFA for VT treatment.
Collapse
|
2
|
Pulsed-field ablation for paroxysmal atrial fibrillation: An indirect comparison of effectiveness among three proprietary devices conducted in the absence of randomized trials. Int J Cardiol 2024; 406:132025. [PMID: 38583595 DOI: 10.1016/j.ijcard.2024.132025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Accepted: 04/04/2024] [Indexed: 04/09/2024]
Abstract
INTRODUCTION In patients with paroxysmal atrial fibrillation, pulsed-field ablation has been developed as an alternative to thermal ablation. Three devices are currently available: Farawave by Boston, PulseSelect by Medtronic, and Varipulse by Johnson. In the present report, we studied the outcomes at 12 months of these three devices using indirect comparisons. METHODS A standard PubMed search was conducted that identified all studies evaluating these devices in patients with paroxysmal atrial fibrillation. The endpoint was freedom from arrhythmia recurrence. Kaplan-Meier curves were subjected to the IPDfromKM method that generated reconstructed patients. Standard time-to-event statistical testss (including heterogeneity assessment) were performed. RESULTS Our analysis included 9 studies (8 single-arm and 1 randomized trial based on Farawave for a total of 1916 patients). A significant heterogeneity was found across the trials using Farawave because the outcomes found in the single-arm trials were better than those found in the randomized trial. Farawave (according exclusively to the results of the randomized trial), PulseSelect, and Varipulse showed a similar time-course of their respective outcomes with no significant difference. The single-arm trials using Farawave showed better outcomes than the randomized trial using Farawave and the pivotal trials using PulseSelect and Varipulse. DISCUSSION Our study provided an updated overview of all the studies that have so far used pulsed-fileld ablation in patients with paroxysmal atrial fibrillation.
Collapse
|
3
|
Multidisciplinary management strategies for atrial fibrillation. Curr Probl Cardiol 2024; 49:102514. [PMID: 38518845 DOI: 10.1016/j.cpcardiol.2024.102514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/13/2024] [Indexed: 03/24/2024]
Abstract
There has been a significant increase in the prevalence of atrial fibrillation (AF) over the past 30 years. Pulmonary vein isolation (PVI) is an effective treatment for AF, but research investigations have shown that AF recurrence still occurs in a significant number of patients after ablation. Heart rhythm outcomes following catheter ablation are correlated with numerous clinical factors, and researchers developed predictive models by integrating risk factors to predict the risk of recurrence of atrial fibrillation. The purpose of this article is to outline the risk scores for predicting cardiac rhythm outcomes after PVI and to discuss the modifiable factors that increase the risk of recurrence of AF, with the hope of further improving catheter ablation efficacy through preoperative identification of high-risk populations and postoperative management of modifiable risk factors.
Collapse
|
4
|
Catheter Ablation of Ventricular Tachycardia in Ischemic Heart Disease: What Is Known and New Perspectives. Curr Heart Fail Rep 2024; 21:174-185. [PMID: 38536648 DOI: 10.1007/s11897-024-00656-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/04/2024] [Indexed: 05/14/2024]
Abstract
PURPOSE OF THE REVIEW This review aims to evaluate current evidence regarding ventricular tachycardia ablation in patients with ischemic heart disease and explore novel approaches currently developing to improve procedural and long-term outcomes. RECENT FINDINGS Recently published trials (PARTITA, PAUSE-SCD, and SURVIVE-VT) have demonstrated the prognostic benefit of prophylactic ventricular tachycardia ablation compared to current clinical practice. Advanced cardiac imaging provides a valuable pre-procedural evaluation of the arrhythmogenic substrate, identifying ablation targets non-invasively. Advanced cardiac mapping techniques allow to better characterize arrhythmogenic substrate during ablation procedure. Emerging technologies like pulsed field ablation and ultra-low temperature cryoablation show promise in ventricular tachycardia ablation. Advancements in mapping techniques, ablation technologies, and pre-procedural cardiac imaging offer promise for improving ventricular tachycardia ablation outcomes in ischemic heart disease.
Collapse
|
5
|
Pulsed Field Energy in Atrial Fibrillation Ablation: From Physical Principles to Clinical Applications. J Clin Med 2024; 13:2980. [PMID: 38792520 PMCID: PMC11121906 DOI: 10.3390/jcm13102980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/13/2024] [Accepted: 05/15/2024] [Indexed: 05/26/2024] Open
Abstract
Atrial fibrillation, representing the most prevalent sustained cardiac arrhythmia, significantly impacts stroke risk and cardiovascular mortality. Historically managed with antiarrhythmic drugs with limited efficacy, and more recently, catheter ablation, the interventional approach field is still evolving with technological advances. This review highlights pulsed field ablation (PFA), a revolutionary technique gaining prominence in interventional electrophysiology because of its efficacy and safety. PFA employs non-thermal electric fields to create irreversible electroporation, disrupting cell membranes selectively within myocardial tissue, thus preventing the non-selective damage associated with traditional thermal ablation methods like radiofrequency or cryoablation. Clinical studies have consistently shown PFA's ability to achieve pulmonary vein isolation-a cornerstone of AF treatment-rapidly and with minimal complications. Notably, PFA reduces procedure times and has shown a lower incidence of esophageal and phrenic nerve damage, two common concerns with thermal techniques. Emerging from oncological applications, the principles of electroporation provide a unique tissue-selective ablation method that minimizes collateral damage. This review synthesizes findings from foundational animal studies through to recent clinical trials, such as the MANIFEST-PF and ADVENT trials, demonstrating PFA's effectiveness and safety. Future perspectives point towards expanding indications and refinement of techniques that promise to improve AF management outcomes further. PFA represents a paradigm shift in AF ablation, offering a safer, faster, and equally effective alternative to conventional methods. This synthesis of its development and clinical application outlines its potential to become the new standard in AF treatment protocols.
Collapse
|
6
|
Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial. Nat Med 2024:10.1038/s41591-024-03022-6. [PMID: 38760584 DOI: 10.1038/s41591-024-03022-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Accepted: 04/26/2024] [Indexed: 05/19/2024]
Abstract
Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .
Collapse
|
7
|
Recurrences after Pulsed Field Ablation of Atrial Fibrillation: Incidence, Mechanisms, Predictors, and Comparison with Thermal Energy. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:817. [PMID: 38793000 PMCID: PMC11123187 DOI: 10.3390/medicina60050817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 05/12/2024] [Accepted: 05/13/2024] [Indexed: 05/26/2024]
Abstract
Pulsed Field Ablation (PFA) is the latest and most intriguing technology for catheter ablation of atrial fibrillation, due to its capability to generate irreversible and cardiomyocytes-selective electroporation of cell membranes by delivering microsecond-lasting high-voltage electrical fields, leading to high expectations. The first trials to assess the clinical success of PFA, reported an arrhythmia-free survival at 1-year of 78.5%, while other trials showed less enthusiastic results: 66.2% in paroxysmal and 55.1% in persistent AF. Nevertheless, real world data are encouraging. The isolation of pulmonary veins with PFA is easily achieved with 100% acute success. Systematic invasive remapping showed a high prevalence of durable pulmonary vein isolation at 75 and 90 days (range 84-96%), which were significatively lower in redo procedures (64.3%). The advent of PFA is prompting a reconsideration of the role of the autonomic nervous system in AF ablation, as PFA-related sparing of the ganglionated plexi could lead to the still undetermined effect on late arrhythmias' recurrences. Moreover, a new concept of a blanking period could be formulated with PFA, according to its different mechanism of myocardial injury, with less inflammation and less chronic fibrosis. Finally, in this review, we also compare PFA with thermal energy.
Collapse
|
8
|
Advances in Clinical Cardiology 2023: A Summary of Key Clinical Trials. Adv Ther 2024:10.1007/s12325-024-02877-y. [PMID: 38743242 DOI: 10.1007/s12325-024-02877-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 04/16/2024] [Indexed: 05/16/2024]
Abstract
INTRODUCTION Over the course of 2023, numerous key clinical trials with valuable contributions to clinical cardiology were published or presented at major international conferences. This review seeks to summarise these trials and reflect on their clinical context. METHODS The authors collated and reviewed clinical trials presented at major cardiology conferences during 2023 including the American College of Cardiology (ACC), European Association for Percutaneous Cardiovascular Interventions (EuroPCR), European Society of Cardiology (ESC), Transcatheter Cardiovascular Therapeutics (TCT), American Heart Association (AHA), European Heart Rhythm Association (EHRA), Society for Cardiovascular Angiography and Interventions (SCAI), TVT-The Heart Summit (TVT) and Cardiovascular Research Technologies (CRT). Trials with a broad relevance to the cardiology community and those with potential to change current practice were included. RESULTS A total of 80 key cardiology clinical trials were identified for inclusion. Key trials in acute coronary syndrome (ACS) and antiplatelet management such as HOST-IDEA, T-PASS and STOP-DAPT3 were included in addition to several pivotal interventional trials such as ORBITA 2, MULTISTARS-AMI, ILUMIEN-IV, OCTIVUS and OCTOBER. Additionally, several trials evaluated new stent design and technology such as BIOSTEMI, PARTHENOPE and TRANSFORM. Structural intervention trials included long-term data from PARTNER 3, new data on the durability of transcatheter aortic valve intervention (TAVI), in addition to major new trials regarding transcatheter tricuspid valve intervention from TRISCEND II. Heart failure (HF) and prevention covered several key studies including DAPA-MI, STEP-HF, ADVOR, DICTATE HF and CAMEO-DAPA. In cardiac devices and electrophysiology, several trial exploring novel ablation strategies in atrial fibrillation (AF) such as PULSED AF and ADVENT were presented with further data evaluating the efficacy of anticoagulation in subclinical AF in NOAH-AFNET 6, FRAIL AF and AZALEA-TIMI 71. CONCLUSION This article presents a summary of key clinical cardiology trials published and presented during the past year and should be of interest to both practising clinicians and researchers.
Collapse
|
9
|
Sex-based differences and risk of recurrence in patients with atrial fibrillation undergoing pulmonary vein isolation. Int J Cardiol 2024; 409:132161. [PMID: 38744339 DOI: 10.1016/j.ijcard.2024.132161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 04/28/2024] [Accepted: 05/10/2024] [Indexed: 05/16/2024]
Abstract
INTRODUCTION Studies suggest increased likelihood of atrial fibrillation (AF) recurrence after catheter ablation (CA) in women than in men, indicating that sex may be an independent risk factor for recurrence. Nevertheless, the influence of sex on AF recurrence and underlying mechanisms remains unclear. METHODS Retrospective, single-centre study including patients undergoing AF CA between 2017 and 2021. Late recurrence (LR) was defined as AF recurrence ≥90 days after ablation, whereas early recurrence (ER) occurred within 90 days. RESULTS 656 patients (32% women) were included, with a median follow-up period of 26 months. Compared to men, women undergoing CA were older, had higher body mass indexes, and had higher rates of hypertension, thyroid dysfunction, and valvular disease. Women also had increased LR risk after CA (HR 1.76, 95% CI [1.19, 2.59]). A time-split multivariable analysis at one year of follow-up showed no difference in LR risk during the first 12 months after CA (HR 1.19, 95% CI [0.73, 1.94]); however, LR risk increased in women (HR 2.90, 95% CI [1.68, 5.01]) after 12 months. In a sex-stratified analysis, coronary calcium score (CCS) >100 was associated with increased LR risk in men (HR 1.81, 95% CI [1.06, 3.08]), but not in women. Cardiac adipose tissue volume was not associated with increased LR risk. CONCLUSIONS Fewer women underwent CA than men and LR was more frequent in women, particularly one year after the procedure. CCS was associated with increased LR risk in men.
Collapse
|
10
|
Novel methodology for nonfluoroscopic wire visualization during pulsed field ablation for the treatment of atrial fibrillation. Heart Rhythm 2024:S1547-5271(24)02527-X. [PMID: 38704077 DOI: 10.1016/j.hrthm.2024.04.093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 04/24/2024] [Accepted: 04/27/2024] [Indexed: 05/06/2024]
|
11
|
AF Ablation Using a Novel "Single-Shot" Map-and-Ablate Spherical Array Pulsed Field Ablation Catheter: 1-Year Outcomes of the First-in-Human PULSE-EU Trial. Heart Rhythm 2024:S1547-5271(24)02536-0. [PMID: 38768840 DOI: 10.1016/j.hrthm.2024.04.102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 04/27/2024] [Accepted: 04/30/2024] [Indexed: 05/22/2024]
Abstract
BACKGROUND During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. Recently, a novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was studied in a first-in-human trial of atrial fibrillation. OBJECTIVE To report lesion durability data, safety and 12-months effectiveness outcomes. METHODS The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and deliver biphasic pulses (ungated 1.7kV pulses; ∼40 sec/application). Ablation sites included pulmonary veins (PVs), and in selected patients, posterior wall (PW) and mitral isthmus (MI). Follow-up was invasive remapping at ∼3 months, ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI, PVI durability and atrial arrhythmia recurrence. RESULTS In the 48-patient AF cohort (paroxysmal-48% / persistent-52%), lesion sets included PVI (n=48; 1.2 applications/PV), PW (n=20; 3.6 applications/PW) and MI (n=11; 2.9 applications/MI). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 PWs (100%) and 10 of 11 MIs (91%). Pulse delivery time, LA catheter dwell time and procedure time was 61.5±32.8 seconds, 53.9±26.5 min and 87.8±29.8 min, respectively. Remapping (43 of 48 pts; 89.5%) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy.
Collapse
|
12
|
Dual energy for pulmonary vein isolation using dual-energy focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 3-month results. Europace 2024; 26:euae088. [PMID: 38696675 PMCID: PMC11065353 DOI: 10.1093/europace/euae088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Accepted: 04/03/2024] [Indexed: 05/04/2024] Open
Abstract
AIMS Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT05752487.
Collapse
|
13
|
2023 Cardiac Society of Australia and New Zealand Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation. Heart Lung Circ 2024:S1443-9506(24)00170-7. [PMID: 38702234 DOI: 10.1016/j.hlc.2023.12.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 12/14/2023] [Indexed: 05/06/2024]
Abstract
Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.
Collapse
|
14
|
Initial clinical experience with the balloon-in-basket pulsed field ablation system: acute results of the VOLT CE mark feasibility study. Europace 2024; 26:euae118. [PMID: 38701222 PMCID: PMC11098042 DOI: 10.1093/europace/euae118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Accepted: 04/29/2024] [Indexed: 05/05/2024] Open
Abstract
AIMS Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation. METHODS AND RESULTS The VOLT CE Mark Study is a pre-market, prospective, multi-centre, single-arm study to evaluate the safety and effectiveness of the Volt™ PFA system for the treatment of paroxysmal (PAF) or persistent AF (PersAF). Feasibility sub-study subjects underwent phrenic nerve evaluation, endoscopy, chest computed tomography, and cerebral magnetic resonance imaging. Study endpoints were the rate of primary serious adverse event within 7 days and acute procedural effectiveness. A total of 32 subjects (age 61.6 ± 9.6 years, 65.6% male, 84.4% PAF) were enrolled and treated in the feasibility sub-study and completed a 30-day follow-up. Acute effectiveness was achieved in 99.2% (127/128) of treated PVs (96.9% of subjects, 31/32) with 23.8 ± 4.2 PFA applications/subject. Procedure, fluoroscopy, LA dwell, and transpired ablation times were 124.6 ± 28.1, 19.8 ± 8.9, 53.0 ± 21.0, and 48.0 ± 19.9 min, respectively. Systematic assessments of initial safety revealed no phrenic nerve injury, pulmonary vein stenosis, or oesophageal lesions causally related to the PFA system and three subjects with silent cerebral lesions (9.4%). There were no primary serious adverse events. CONCLUSION The initial clinical use of the Volt PFA System demonstrates acute safety and effectiveness in the treatment of symptomatic, drug refractory AF.
Collapse
|
15
|
Meta-analysis of pulsed-field ablation versus cryoablation for atrial fibrillation. Pacing Clin Electrophysiol 2024; 47:603-613. [PMID: 38525525 DOI: 10.1111/pace.14971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/28/2024] [Accepted: 03/07/2024] [Indexed: 03/26/2024]
Abstract
PURPOSE The available data on the treatment strategy of pulsed field ablation (PFA) for patients with atrial fibrillation (AF) is limited. This study aims to provide a comparative analysis of the efficacy, safety, and procedural efficiency between PFA and cryoballoon ablation (CBA) for AF. METHODS We conducted a comprehensive search of the EMBASE, PubMed, Cochrane Library, and ClinicalTrials.gov databases to identify trials comparing PFA with CBA for AF from their inception until December 2023. The odds ratio (OR) and mean difference (MD), along with a 95% confidence interval (CI), were utilized as measures of treatment effect. RESULTS The analysis included 15 eligible trials with a total enrollment of 1880 patients. No significant differences were found in recurrent atrial arrhythmia (OR 0.83, 95% CI 0.64, 1.07) or periprocedural complications (OR 0.78, 95% CI 0.46, 1.30) between the two ablation techniques examined in this study. However, the PFA technique demonstrated a significantly shorter procedure time (MD -7.17, 95% CI -13.60, -0.73), but a longer fluoroscopy time (MD 2.53, 95% CI 0.87, 4.19). Similarly, PFA was found to be significantly associated with a decreased incidence of phrenic nerve palsy (OR 0.20, 95% CI 0.07, 0.59), but an increased incidence of cardiac tamponade (OR 4.07, 95% CI 1.15, 14.39). Moreover, there was a significantly higher release of troponin with PFA compared to CBA (MD 470.28, 95% CI 18.89, 921.67), while the increase in S100 protein and heart rate was significantly lower with PFA than with CBA (MD -64.41, 95% CI -105.46, -17.36), (MD -8.76, 95% CI -15.12, -2.40). CONCLUSION The utilization of PFA provides a safer, time-saving, and tissue-specific procedure compared to CBA, while maintaining comparable success rates. This has the potential to enhance procedural efficiency and optimize resource utilization in clinical practice. These findings underscore the feasibility and promise of PFA as an alternative technique for PVI in patients with AF.
Collapse
|
16
|
Difference between endocardial and epicardial application of pulsed fields for targeting Epicardial Ganglia: An in-silico modelling study. Comput Biol Med 2024; 174:108490. [PMID: 38642490 DOI: 10.1016/j.compbiomed.2024.108490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 04/04/2024] [Accepted: 04/15/2024] [Indexed: 04/22/2024]
Abstract
BACKGROUND Pulsed Field Ablation (PFA) has recently been proposed as a non-thermal energy to treat atrial fibrillation by selective ablation of ganglionated plexi (GP) embedded in epicardial fat. While some of PFA-technologies use an endocardial approach, others use epicardial access with promising pre-clinical results. However, as each technology uses a different and sometimes proprietary pulse application protocol, the comparation between endocardial vs. epicardial approach is almost impossible in experimental terms. For this reason, our study, based on a computational model, allows a direct comparison of electric field distribution and thermal-side effects of both approaches under equal conditions in terms of electrode design, pulse protocol and anatomical characteristics of the tissues involved. METHODS 2D computational models with axial symmetry were built for endocardial and epicardial approaches. Atrial (1.5-2.5 mm) and fat (1-5 mm) thicknesses were varied to simulate a representative sample of what happens during PFA ablation for different applied voltage values (1000, 1500 and 2000 V) and number of pulses (30 and 50). RESULTS The epicardial approach was superior for capturing greater volumes of fat when the applied voltage was increased: 231 mm3/kV with the epicardial approach vs. 182 mm3/kV with the endocardial approach. In relation to collateral damage to the myocardium, the epicardial approach considerably spares the myocardium, unlike what happens with the endocardial approach. Although the epicardial approach caused much more thermal damage in the fat, there is not a significant difference between the approaches in terms of size of thermal damage in the myocardium. CONCLUSIONS Our results suggest that epicardial PFA ablation of GPs is more effective than an endocardial approach. The proximity and directionality of the electric field deposited using an epicardial approach are key to ensuring that higher electric field strengths and increased temperatures are obtained within the epicardial fat, thus contributing to selective ablation of the GPs with minimal myocardial damage.
Collapse
|
17
|
Predictors of Success for Pulmonary Vein Isolation With Pulsed-field Ablation Using a Variable-loop Catheter With 3D Mapping Integration: Complete 12-month Outcomes From inspIRE. Circ Arrhythm Electrophysiol 2024; 17:e012667. [PMID: 38655693 PMCID: PMC11111320 DOI: 10.1161/circep.123.012667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 02/12/2024] [Indexed: 04/26/2024]
Abstract
BACKGROUND We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.
Collapse
|
18
|
Chinese guidelines for the diagnosis and management of atrial fibrillation. Pacing Clin Electrophysiol 2024. [PMID: 38687179 DOI: 10.1111/pace.14920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 11/30/2023] [Indexed: 05/02/2024]
Abstract
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, significantly impacting patients' quality of life and increasing the risk of death, stroke, heart failure, and dementia. Over the past two decades, there have been significant breakthroughs in AF risk prediction and screening, stroke prevention, rhythm control, catheter ablation, and integrated management. During this period, the scale, quality, and experience of AF management in China have greatly improved, providing a solid foundation for the development of the guidelines for the diagnosis and management of AF. To further promote standardized AF management, and apply new technologies and concepts to clinical practice timely and fully, the Chinese Society of Cardiology of Chinese Medical Association and the Heart Rhythm Committee of Chinese Society of Biomedical Engineering jointly developed the Chinese Guidelines for the Diagnosis and Management of Atrial Fibrillation. The guidelines comprehensively elaborated on various aspects of AF management and proposed the CHA2DS2‑VASc‑60 stroke risk score based on the characteristics of the Asian AF population. The guidelines also reevaluated the clinical application of AF screening, emphasized the significance of early rhythm control, and highlighted the central role of catheter ablation in rhythm control.
Collapse
|
19
|
Surgical Coronary Revascularization in Patients With Underlying Atrial Fibrillation: State-of-the-Art Review. Mayo Clin Proc 2024:S0025-6196(23)00606-7. [PMID: 38661599 DOI: 10.1016/j.mayocp.2023.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/30/2023] [Accepted: 12/14/2023] [Indexed: 04/26/2024]
Abstract
The number of individuals referred for coronary artery bypass grafting (CABG) with preoperative atrial fibrillation (AF) is reported to be 8% to 20%. Atrial fibrillation is a known marker of high-risk patients as it was repeatedly found to negatively influence survival. Therefore, when performing surgical revascularization, consideration should be given to the concomitant treatment of the arrhythmia, the clinical consequences of the arrhythmia itself, and the selection of adequate surgical techniques. This state-of-the-art review aimed to provide a comprehensive analysis of the current understanding of, advancements in, and optimal strategies for CABG in patients with underlying AF. The following topics are considered: stroke prevention, prophylaxis and occurrence of postoperative AF, the role of surgical ablation and left atrial appendage occlusion, and an on-pump vs off-pump strategy. Multiple acute complications can occur in patients with preexisting AF undergoing CABG, each of which can have a significant effect on patient outcomes. Long-term results in these patients and the future perspectives of this scientific area were also addressed. Preoperative arrhythmia should always be considered for surgical ablation because such an approach improves prognosis without increasing perioperative risk. While planning a revascularization strategy, it should be noted that although off-pump coronary artery bypass provides better short-term outcomes, conventional on-pump approach may be beneficial at long-term follow-up. By collecting the current evidence, addressing knowledge gaps, and offering practical recommendations, this state-of-the-art review serves as a valuable resource for clinicians involved in the management of patients with AF undergoing CABG, ultimately contributing to improved outcomes and enhanced patient care.
Collapse
|
20
|
A real-time signal processing software package for the electrophysiology laboratory. J Cardiovasc Electrophysiol 2024. [PMID: 38654418 DOI: 10.1111/jce.16281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/13/2024] [Accepted: 04/01/2024] [Indexed: 04/26/2024]
Abstract
BACKGROUND Real-time signal processing has to date been difficult to implement in the clinical electrophysiology laboratory. To date, no open access software solutions are available in electrophysiology (EP) laboratories to facilitate real-time intraprocedural signal analysis. We aimed to develop an open access, scalable Python plug-in to allow real-time signal processing during human EP procedures. METHODS AND RESULTS A Python-based plug in for the widely available EnsiteX mapping system was developed. This plug-in utilized the LiveSync feature of the system to allow real-time signal analysis. An open access library was developed to allow end-users to implement real-time signal analysis using this platform, implemented in the Python programming language https://github.com/anand9176/WaveWatch5000Public. CONCLUSION We have developed and demonstrated the feasibility of a readily scalable and open-access Python-based plug in to an electroanatomic mapping system (EnSiteX) to allow real-time processing and display of electrogram (EGM) based information for the procedural electrophysiologist to view intraprocedurally in the electrophysiology laboratory. The availability, to the clinician, of traditional and novel EGM-based metrics at the time of intervention, such as atrial fibrillation ablation, allows for key mechanistic insights into critical unresolved questions regarding arrhythmia mechanism.
Collapse
|
21
|
Vein of Marshall Ethanol Infusion for AF Ablation; A Review. J Clin Med 2024; 13:2438. [PMID: 38673710 PMCID: PMC11050818 DOI: 10.3390/jcm13082438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/14/2024] [Accepted: 04/17/2024] [Indexed: 04/28/2024] Open
Abstract
The outcomes of persistent atrial fibrillation (AF) ablation are modest with various adjunctive strategies beyond pulmonary vein isolation (PVI) yielding largely disappointing results in randomised controlled trials. Linear ablation is a commonly employed adjunct strategy but is limited by difficulty in achieving durable bidirectional block, particularly at the mitral isthmus. Epicardial connections play a role in AF initiation and perpetuation. The ligament of Marshall has been implicated as a source of AF triggers and is known to harbour sympathetic and parasympathetic nerve fibres that contribute to AF perpetuation. Ethanol infusion into the Vein of Marshall, a remnant of the superior vena cava and key component of the ligament of Marshall, may eliminate these AF triggers and can facilitate the ease of obtaining durable mitral isthmus block. While early trials have demonstrated the potential of Vein of Marshall 'ethanolisation' to reduce arrhythmia recurrence after persistent AF ablation, further randomised trials are needed to fully determine the potential long-term outcome benefits afforded by this technique.
Collapse
|
22
|
2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. J Interv Card Electrophysiol 2024:10.1007/s10840-024-01771-5. [PMID: 38609733 DOI: 10.1007/s10840-024-01771-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/14/2024]
Abstract
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.
Collapse
|
23
|
Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation. Heart Rhythm 2024:S1547-5271(24)02372-5. [PMID: 38614191 DOI: 10.1016/j.hrthm.2024.04.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/26/2024] [Accepted: 04/04/2024] [Indexed: 04/15/2024]
Abstract
BACKGROUND Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA. METHODS Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events. RESULTS A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010). CONCLUSION In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.
Collapse
|
24
|
Long-Term Results of the Mini Maze Standalone Bi-Atrial Surgical Ablation: A 10-Year Follow-Up. J Clin Med 2024; 13:2195. [PMID: 38673468 PMCID: PMC11050341 DOI: 10.3390/jcm13082195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 04/01/2024] [Accepted: 04/10/2024] [Indexed: 04/28/2024] Open
Abstract
Background: One way to treat atrial fibrillation is through surgical ablation. However, the literature only provides information on patient follow-up results for up to 5 years. Methods: In order to assess long-term monitoring data over ten years, this retrospective study included 58 patients with paroxysmal or persistent atrial fibrillation who underwent Mini Maze surgical ablation at Santaros Clinics between 1 February 2009 and 1 June 2014. The follow-up time after surgery was 144 ± 48 months. We evaluated the absence of atrial fibrillation, echocardiographic and clinical parameters, and EHRA score. Results: Sinus rhythm remained in 69.4%, 75.5%, 55.6%, and 44.1% of patients with paroxysmal AF, and 68,2%, 59.1%, 50%, and 41.9% of patients with persistent AF (p = 0.681). In the post-operative period, one patient (1.7%) had a transient ischemic attack, and another patient (1.7%) had a thoracotomy for post-operative bleeding. A total of 20% of patients were diagnosed with a post-operative respiratory tract infection. EHRA scores showed that patients' quality of life improved after they underwent Mini Maze surgical ablation. Conclusions: Despite AF recurrences after surgery, quality of life remains better than before surgery, showing that Mini Maze surgery is an effective and safe second-line treatment method for atrial fibrillation.
Collapse
|
25
|
European Heart Rhythm Association (EHRA)/Heart Rhythm Society (HRS)/Asia Pacific Heart Rhythm Society (APHRS)/Latin American Heart Rhythm Society (LAHRS) expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 2024:S1547-5271(24)00261-3. [PMID: 38597857 DOI: 10.1016/j.hrthm.2024.03.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Accepted: 03/11/2024] [Indexed: 04/11/2024]
|
26
|
New Frontiers in Electrocardiography, Cardiac Arrhythmias, and Arrhythmogenic Disorders. J Clin Med 2024; 13:2047. [PMID: 38610811 PMCID: PMC11012577 DOI: 10.3390/jcm13072047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Accepted: 03/25/2024] [Indexed: 04/14/2024] Open
Abstract
In recent decades, diagnosing, risk-stratifying, and treating patients with primary electrical diseases, as well as heart rhythm disorders, have improved substantially [...].
Collapse
|
27
|
Pulsed field ablation versus thermal energy ablation for atrial fibrillation: a systematic review and meta-analysis of procedural efficiency, safety, and efficacy. J Interv Card Electrophysiol 2024; 67:639-648. [PMID: 37855992 PMCID: PMC11016003 DOI: 10.1007/s10840-023-01660-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 10/02/2023] [Indexed: 10/20/2023]
Abstract
BACKGROUND Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.
Collapse
|
28
|
One-year outcomes of pulmonary vein isolation with a novel cryoballoon: Primary results of the FROZEN AF trial. J Cardiovasc Electrophysiol 2024; 35:832-842. [PMID: 38448797 DOI: 10.1111/jce.16220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 01/27/2024] [Accepted: 02/05/2024] [Indexed: 03/08/2024]
Abstract
INTRODUCTION Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.
Collapse
|
29
|
Therapeutic perspectives of high pulse repetition rate electroporation. Bioelectrochemistry 2024; 156:108629. [PMID: 38159429 DOI: 10.1016/j.bioelechem.2023.108629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 12/15/2023] [Accepted: 12/16/2023] [Indexed: 01/03/2024]
Abstract
Electroporation, a technique that uses electrical pulses to temporarily or permanently destabilize cell membranes, is increasingly used in cancer treatment, gene therapy, and cardiac tissue ablation. Although the technique is efficient, patients report discomfort and pain. Current strategies that aim to minimize pain and muscle contraction rely on the use of pharmacological agents. Nevertheless, technical improvements might be a valuable tool to minimize adverse events, which occur during the application of standard electroporation protocols. One recent technological strategy involves the use of high pulse repetition rate. The emerging technique, also referred as "high frequency" electroporation, employs short (micro to nanosecond) mono or bipolar pulses at repetition rate ranging from a few kHz to a few MHz. This review provides an overview of the historical background of electric field use and its development in therapies over time. With the aim to understand the rationale for novel electroporation protocols development, we briefly describe the physiological background of neuromuscular stimulation and pain caused by exposure to pulsed electric fields. Then, we summarize the current knowledge on electroporation protocols based on high pulse repetition rates. The advantages and limitations of these protocols are described from the perspective of their therapeutic application.
Collapse
|
30
|
Prospective 1-year results of atrial fibrillation ablation using the pentaspline pulsed field ablation catheter: The initial French experience. Arch Cardiovasc Dis 2024; 117:249-254. [PMID: 38494400 DOI: 10.1016/j.acvd.2024.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 12/29/2023] [Accepted: 01/03/2024] [Indexed: 03/19/2024]
Abstract
BACKGROUND Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.
Collapse
|
31
|
Acute Kidney Injury Resulting From Hemoglobinuria After Pulsed-Field Ablation in Atrial Fibrillation: Is it Preventable? JACC Clin Electrophysiol 2024; 10:709-715. [PMID: 38310489 DOI: 10.1016/j.jacep.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 12/18/2023] [Accepted: 12/18/2023] [Indexed: 02/05/2024]
Abstract
BACKGROUND High-voltage pulses can cause hemolysis. OBJECTIVES The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.
Collapse
|
32
|
First-in-human clinical series of a novel conformable large-lattice pulsed field ablation catheter for pulmonary vein isolation. Europace 2024; 26:euae090. [PMID: 38584468 PMCID: PMC11057205 DOI: 10.1093/europace/euae090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Accepted: 04/03/2024] [Indexed: 04/09/2024] Open
Abstract
AIMS Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.
Collapse
|
33
|
Application of a circular-shaped pulsed field ablation catheter with magnetic sensors for pulmonary vein isolation: a multi-centre clinical study report. Europace 2024; 26:euae068. [PMID: 38584395 PMCID: PMC10999647 DOI: 10.1093/europace/euae068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 02/24/2024] [Indexed: 04/09/2024] Open
Abstract
AIMS A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.
Collapse
|
34
|
Contemporary catheter ablation of complex atrial tachycardias after prior atrial fibrillation ablation: pulsed field vs. radiofrequency current energy ablation guided by high-density mapping. Europace 2024; 26:euae072. [PMID: 38513110 PMCID: PMC11034699 DOI: 10.1093/europace/euae072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 03/12/2024] [Indexed: 03/23/2024] Open
Abstract
AIMS Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44 min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6 min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.
Collapse
|
35
|
2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace 2024; 26:euae043. [PMID: 38587017 PMCID: PMC11000153 DOI: 10.1093/europace/euae043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 01/16/2024] [Indexed: 04/09/2024] Open
Abstract
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .
Collapse
|
36
|
Chinese Guidelines for the Diagnosis and Management of Atrial Fibrillation. J Geriatr Cardiol 2024; 21:251-314. [PMID: 38665287 PMCID: PMC11040055 DOI: 10.26599/1671-5411.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2024] Open
Abstract
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, significantly impacting patients' quality of life and increasing the risk of death, stroke, heart failure, and dementia. Over the past two decades, there have been significant breakthroughs in AF risk prediction and screening, stroke prevention, rhythm control, catheter ablation, and integrated management. During this period, the scale, quality, and experience of AF management in China have greatly improved, providing a solid foundation for the development of guidelines for the diagnosis and management of AF. To further promote standardized AF management, and apply new technologies and concepts to clinical practice in a timely and comprehensive manner, the Chinese Society of Cardiology of the Chinese Medical Association and the Heart Rhythm Committee of the Chinese Society of Biomedical Engineering have jointly developed the Chinese Guidelines for the Diagnosis and Management of Atrial Fibrillation. The guidelines have comprehensively elaborated on various aspects of AF management and proposed the CHA2DS2-VASc-60 stroke risk score based on the characteristics of AF in the Asian population. The guidelines have also reevaluated the clinical application of AF screening, emphasized the significance of early rhythm control, and highlighted the central role of catheter ablation in rhythm control.
Collapse
|
37
|
Pulsed field ablation: A promise with future broad-based applicability or a pause needing further analysis-Is catheter ablation at a crossroads? A critical appraisal of the new challenger-pulsed field ablation. Heart Rhythm 2024:S1547-5271(24)02256-2. [PMID: 38548125 DOI: 10.1016/j.hrthm.2024.03.1763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 03/19/2024] [Accepted: 03/22/2024] [Indexed: 04/17/2024]
|
38
|
Pulsed field ablation technology for pulmonary vein and left atrial posterior wall isolation in patients with persistent atrial fibrillation. J Cardiovasc Electrophysiol 2024. [PMID: 38519418 DOI: 10.1111/jce.16246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/17/2024] [Accepted: 02/28/2024] [Indexed: 03/24/2024]
Abstract
INTRODUCTION Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.
Collapse
|
39
|
CLOSE protocol versus lower ablation index value for paroxysmal atrial fibrillation: A randomized noninferior clinical trial. J Cardiovasc Electrophysiol 2024; 35:469-477. [PMID: 38282257 DOI: 10.1111/jce.16194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 01/02/2024] [Accepted: 01/14/2024] [Indexed: 01/30/2024]
Abstract
INTRODUCTION The optimized ablation index (AI) value for catheter ablation of atrial fibrillation (AF) remains to be defined. We aimed to compare the efficacy and safety of CLOSE protocol and lower AI protocol in paroxysmal AF. METHODS AND RESULTS Patients with symptomatic, drug-resistant paroxysmal AF for first ablation were prospectively enrolled from September 2020 to January 2022. The patients were randomly divided into CLOSE group (AI ≥ 550 for anterior/roof segments and ≥400 for posterior/inferior segments) and lower AI group (AI ≥ 450 for anterior/roof segments and ≥350 for posterior/inferior segments). First-pass isolation, acute pulmonary vein (PV) reconnections, 1-year arrhythmia recurrence, and major complications were assessed. Of the 270 enrolled patients, 238 completed 1-year follow-up (118 in CLOSE group and 120 in lower AI group). First-pass isolation in left PVs was higher in CLOSE group (71.2% vs. 53.3%, p = .005). Acute PV reconnections were comparable between groups (9.3% vs. 14.2%, p = .246). At 1 year, 86.4% in CLOSE group versus 81.7% in lower AI group were free from atrial arrhythmia (log rank p = .334). The proportion difference was -4.8% (95% CI: -14.1% to 4.6%), and p = .475 for noninferiority. Stroke occurred in four patients of lower AI group, and no cardiac tamponade, atrioesophageal fistula, major bleeding or death occurred post procedure. CONCLUSION For patients with paroxysmal AF and treated by AI-guided PV ablation, lower AI is not noninferior to CLOSE protocol.
Collapse
|
40
|
Pulsed-field vs. cryoballoon vs. radiofrequency ablation: a propensity score matched comparison of one-year outcomes after pulmonary vein isolation in patients with paroxysmal atrial fibrillation. J Interv Card Electrophysiol 2024; 67:389-397. [PMID: 37776355 PMCID: PMC10902096 DOI: 10.1007/s10840-023-01651-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 09/14/2023] [Indexed: 10/02/2023]
Abstract
BACKGROUND Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA). METHODS Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients with paroxysmal AF undergoing a first PVI with CBA and RFA were selected using a 1:2:2 propensity score matching. The PFA group followed the standard 32-applications lesion-set protocol, the CBA group a time-to-effect plus 2-min strategy, and the RFA group the CLOSE protocol. Patients were followed with 7d-Holter ECGs 3, 6, and 12 months after ablation. The primary endpoint was recurrence of atrial tachyarrhythmia (ATa) following a blanking period of 3 months. RESULTS A total of 200 patients were included (PFA n = 40; CBA n = 80; RFA n = 80). Median procedure times were shortest with CBA (75 min) followed by PFA (94 min) and RFA (182 min; p < 0.001). Fluoroscopy dose was lowest with RFA (1.6Gycm2) followed by PFA (5.0Gycm2) and CBA (5.7Gycm2; p < 0.001). After a 1-year follow-up, freedom from ATa recurrence was 85.0% with PFA, 66.2% with CBA and 73.8% with RFA (p = 0.12 PFA vs. CBA; p = 0.27 PFA vs. RFA). CONCLUSION In a propensity score matched analysis of patients with paroxysmal AF, freedom from any ATa 1 year after PVI using PFA was favourable and at least as good as for PVI with CBA or RFA.
Collapse
|
41
|
Long-term outcomes of the pentaspline pulsed-field ablation catheter for the treatment of paroxysmal atrial fibrillation: results of the prospective, multicentre FARA-Freedom Study. Europace 2024; 26:euae053. [PMID: 38385529 PMCID: PMC10932745 DOI: 10.1093/europace/euae053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 02/16/2024] [Indexed: 02/23/2024] Open
Abstract
AIMS Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).
Collapse
|
42
|
Esophageal injury, perforation, and fistula formation following atrial fibrillation ablation. J Interv Card Electrophysiol 2024; 67:409-424. [PMID: 38038816 DOI: 10.1007/s10840-023-01708-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 11/21/2023] [Indexed: 12/02/2023]
Abstract
BACKGROUND Esophageal perforation and fistula formation are rare but serious complications following atrial fibrillation ablation. In this review article, we outline the incidence, pathophysiology, predictors, and preventative strategies of this dreaded complication. METHODS We conducted an electronic search in 10 databases/electronic search engines to access relevant publications. All articles reporting complications following atrial fibrillation ablation, including esophageal injury and fistula formation, were included for systematic review. RESULTS A total of 130 manuscripts were identified for the final review process. The overall incidence of esophageal injury following atrial fibrillation ablation was significantly higher with thermal ablation modalities (radiofrequency 5-40%, cryoballoon 3-25%, high-intensity focused ultrasound < 10%) as opposed to non-thermal ablation modalities (no cases reported to date). The incidence of esophageal perforation and fistula formation with the use of thermal ablation modalities is estimated to occur in less than 0.25% of all atrial fibrillation ablation procedures. The use of luminal esophageal temperature monitoring probe and mechanical esophageal deviation showed protective effect toward reducing the incidence of this complication. The prognosis is very poor for patients who develop atrioesophageal fistula, and the condition is rapidly fatal without surgical intervention. CONCLUSIONS Esophageal perforation and fistula formation following atrial fibrillation ablation are rare complications with poor prognosis. Various strategies have been proposed to protect the esophagus and reduce the incidence of this fearful complication. Pulsed field ablation is a promising new ablation technology that may be the future answer toward reducing the incidence of esophageal complications.
Collapse
|
43
|
Repeat pulmonary vein isolation and anterior line ablation using a novel point-by-point pulsed-field ablation system. Heart Rhythm 2024; 21:250-257. [PMID: 38036235 DOI: 10.1016/j.hrthm.2023.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 11/16/2023] [Accepted: 11/24/2023] [Indexed: 12/02/2023]
Abstract
BACKGROUND Pulsed-field ablation (PFA) is a nonthermal energy source for ablation of cardiac arrhythmias. This study investigated the prospective outcomes of a novel PFA generator in conjunction with a commercially available, contact force-sensing, focal ablation catheter. OBJECTIVE The purpose of this study was to assess the feasibility, safety, and lesion characteristics of point-by-point PFA in consecutive patients undergoing repeat ablation of atrial fibrillation (AF). METHODS The study involved reisolation of pulmonary veins (PVs) with electrical reconnection and the creation of an anterior line (AL) in patients with anterior substrate or durable pulmonary vein isolation (PVI). RESULTS In 24 patients (46% female; mean age 67 ± 10 years; 67% persistent AF), successful reisolation of 27 of 27 reconnected PVs (100%) was performed. In 19 patients, AL ablation was performed, with bidirectional block in 16 (84%), median ablation time 26 [21, 33] minutes, and first-pass bidirectional block in 13 patients (68%). Acute AL reconduction occurred in 8 of 19 patients (42%). Among these 8 patients, a subsequent sustained block of the AL was achieved in 5 (63%). Ultra-high-density electroanatomic mapping revealed homogeneous but relatively large low-voltage areas in the ablated regions. Median procedural, left atrial dwell, and fluoroscopy times were 100 [90, 109] minutes, 83 [75, 98] minutes, and 10 [8, 13] minutes, respectively. No major or minor complications occurred. CONCLUSION This study demonstrated feasibility, acute efficacy, and safety of point-by-point PFA for repeat PVI and AL ablation. Further studies are warranted to assess the long-term durability and comparison with established ablation methods.
Collapse
|
44
|
Comparative Safety of Pulsed Field Ablation and Cryoballoon Ablation Technologies for Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation: A Critical Literature Review and Indirect Treatment Comparison. Adv Ther 2024; 41:932-944. [PMID: 38185778 PMCID: PMC10879347 DOI: 10.1007/s12325-023-02765-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 12/06/2023] [Indexed: 01/09/2024]
Abstract
INTRODUCTION Cryoballoon ablation (CBA) is a standard catheter ablation technology with demonstrated clinical effectiveness for the treatment of paroxysmal atrial fibrillation (PAF); however, it can be associated with major adverse events, including phrenic nerve paralysis. Pulsed field ablation (PFA) is a novel, minimally thermal technology with comparable effectiveness and low safety risk. This study aimed to compare the safety profiles of PFA and CBA through critical analyses of the literature and indirect treatment comparisons. METHODS Studies were identified by searching the MEDLINE database and the Clinicaltrials.gov registry. Registered clinical trials and/or Food and Drug Administration Investigation Device Exemption (FDA IDE) studies evaluating PFA or CBA in adult patients with drug-refractory PAF between January 2008 and March 2023 were selected. Comparative safety between PFA and CBA was assessed for major and prespecified adverse events. Indirect comparisons were conducted using the proportion of patients experiencing adverse events and confirmed with single-arm meta-analyses and sensitivity analyses. RESULTS Data were extracted from three PFA publications including a total of 497 patients and six CBA studies including a total of 1113 patients. The analysis revealed that PFA was associated with significantly lower risk of major adverse events {risk difference - 4.3% [95% confidence interval (CI) - 5.8, - 2.8]; risk ratio 0.16 [95% CI 0.07, 0.45]} and prespecified adverse events [risk difference - 2.5% (95% CI - 4.4, - 0.5); risk ratio 0.53 (95% CI 0.31, 0.96)]. Meta-analyses confirmed the lower rate of major adverse events for PFA [0.4% (95% CI 0.0, 1.3)] vs. CBA [5.6% (95% CI 2.6, 8.6)] and prespecified adverse events for PFA [2.7% (95% CI 1.2, 4.1)] vs. CBA [5.8% (95% CI 2.7, 9.0)]. Sensitivity analyses exploring heterogeneity across studies confirmed robustness of the main analyses. CONCLUSION The findings of this study show that PFA has a more favorable safety profile than CBA, with significantly lower risks of major and prespecified adverse events. These indirect comparisons help contextualize the safety of PFA compared to CBA for the treatment of drug-refractory PAF in the absence of head-to-head studies.
Collapse
|
45
|
Managing vagal responses induced by pulsed field ablation: Go right first? Heart Rhythm 2024:S1547-5271(24)00200-5. [PMID: 38369036 DOI: 10.1016/j.hrthm.2024.02.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 02/14/2024] [Indexed: 02/20/2024]
|
46
|
Ablation Versus Antiarrhythmic Drugs as First-Line Therapy for Treatment-Naive Atrial Fibrillation: A Systematic Review and Meta-Analysis. Am J Cardiol 2024; 213:63-68. [PMID: 38040282 DOI: 10.1016/j.amjcard.2023.11.052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 11/12/2023] [Accepted: 11/21/2023] [Indexed: 12/03/2023]
Abstract
Evidence on the relative safety and efficacy of atrial fibrillation catheter ablation and antiarrhythmic drugs (AADs) as the first-line therapy for patients with treatment-naive atrial fibrillation (AF) remains disputed. Digital databases were queried to identify relevant randomized controlled trials. The incidence of recurrent AF, major adverse cardiovascular events, and its components (all-cause death, nonfatal stroke, and bleeding) were compared using the DerSimonian and Laird method under the random-effects model to calculate pooled unadjusted risk ratio (RR) with 95% confidence intervals (CIs). A total of 6 randomized controlled trials consisting of 1,120 patients (574 ablation and 549 AADs) were included in the final analysis. Over a median follow-up of 1 year, the risk of any AF recurrence (RR 0.54, 95% CI 0.39 to 0.75) was significantly lower in patients receiving ablation than in patients receiving AADs. However, there was similar risk of major adverse cardiovascular events (RR 2.65, 95% CI 0.61 to 11.46), trial-defined composite end point of adverse events (RR 0.71, 95% CI 0.28 to 1.80), stroke (RR 2.42, 95% CI 0.22 to 26.51), all-cause mortality (RR 1.98, 95% CI 0.28 to 13.90), and procedure/medication failure (RR 2.65, 95% CI 0.61 to 11.46) with both therapies. In conclusion, in patients presenting with treatment-naive AF, ablation as a first-line therapy lowers the risk of AF recurrence with no associated increase in major adverse events, stroke, and mortality compared with AADs.
Collapse
|
47
|
Pulsed field ablation for atrial fibrillation in real-life settings: Efficacy, safety, and lesion durability in patients with recurrences. Heart Rhythm 2024:S1547-5271(24)00127-9. [PMID: 38341122 DOI: 10.1016/j.hrthm.2024.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/01/2024] [Accepted: 02/02/2024] [Indexed: 02/12/2024]
|
48
|
A pilot clinical assessment of biphasic asymmetric pulsed field ablation catheter for pulmonary vein isolation. Front Cardiovasc Med 2024; 11:1266195. [PMID: 38385135 PMCID: PMC10879394 DOI: 10.3389/fcvm.2024.1266195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 01/24/2024] [Indexed: 02/23/2024] Open
Abstract
Pulsed field ablation (PFA) is a new treatment for atrial fibrillation (AF), and its selective ablation characteristics give it a significant advantage in treatment. In previous cellular and animal experiments, we have demonstrated that biphasic asymmetric pulses can be used to ablate myocardial tissue. However, small-scale clinical trials are needed to test whether this approach is safe and feasible before extensive clinical trials can be performed. Therefore, the purpose of this experiment is to determine the safety and feasibility of biphasic asymmetric pulses in patients with AF and is to lay the foundation for a larger clinical trial. Ablation was performed in 10 patients with AF using biphasic asymmetric pulses. Voltage mapping was performed before and after PFA operation to help us detect the change in the electrical voltage of the pulmonary veins (PV). 3-Dimensional mapping system showed continuous low potential in the ablation site, and pulmonary vein isolation (PVI) was achieved in all four PV of the patients. There were no recurrences, PV stenosis, or other serious adverse events during the 12 months follow-up. The results suggest that PFA using biphasic asymmetric waveforms for patients with AF is safe, durable, and effective and that a larger clinical trial could begin. Clinical Trial Registration https://www.chictr.org.cn/, identifier, ChiCTR2100051894.
Collapse
|
49
|
Myocardial injury and inflammation following pulsed-field ablation and very high-power short-duration ablation for atrial fibrillation. J Cardiovasc Electrophysiol 2024; 35:317-327. [PMID: 38105426 DOI: 10.1111/jce.16157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/20/2023] [Accepted: 12/04/2023] [Indexed: 12/19/2023]
Abstract
INTRODUCTION Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.
Collapse
|
50
|
Impact of Left Atrial Posterior Wall Ablation During Pulsed-Field Ablation for Persistent Atrial Fibrillation. JACC Clin Electrophysiol 2024:S2405-500X(24)00030-6. [PMID: 38430087 DOI: 10.1016/j.jacep.2024.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 01/23/2024] [Accepted: 01/24/2024] [Indexed: 03/03/2024]
Abstract
BACKGROUND Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.
Collapse
|