1
|
Estevez-Laborí F, O'Brien B, González-Suárez A. Difference between endocardial and epicardial application of pulsed fields for targeting Epicardial Ganglia: An in-silico modelling study. Comput Biol Med 2024; 174:108490. [PMID: 38642490 DOI: 10.1016/j.compbiomed.2024.108490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 04/04/2024] [Accepted: 04/15/2024] [Indexed: 04/22/2024]
Abstract
BACKGROUND Pulsed Field Ablation (PFA) has recently been proposed as a non-thermal energy to treat atrial fibrillation by selective ablation of ganglionated plexi (GP) embedded in epicardial fat. While some of PFA-technologies use an endocardial approach, others use epicardial access with promising pre-clinical results. However, as each technology uses a different and sometimes proprietary pulse application protocol, the comparation between endocardial vs. epicardial approach is almost impossible in experimental terms. For this reason, our study, based on a computational model, allows a direct comparison of electric field distribution and thermal-side effects of both approaches under equal conditions in terms of electrode design, pulse protocol and anatomical characteristics of the tissues involved. METHODS 2D computational models with axial symmetry were built for endocardial and epicardial approaches. Atrial (1.5-2.5 mm) and fat (1-5 mm) thicknesses were varied to simulate a representative sample of what happens during PFA ablation for different applied voltage values (1000, 1500 and 2000 V) and number of pulses (30 and 50). RESULTS The epicardial approach was superior for capturing greater volumes of fat when the applied voltage was increased: 231 mm3/kV with the epicardial approach vs. 182 mm3/kV with the endocardial approach. In relation to collateral damage to the myocardium, the epicardial approach considerably spares the myocardium, unlike what happens with the endocardial approach. Although the epicardial approach caused much more thermal damage in the fat, there is not a significant difference between the approaches in terms of size of thermal damage in the myocardium. CONCLUSIONS Our results suggest that epicardial PFA ablation of GPs is more effective than an endocardial approach. The proximity and directionality of the electric field deposited using an epicardial approach are key to ensuring that higher electric field strengths and increased temperatures are obtained within the epicardial fat, thus contributing to selective ablation of the GPs with minimal myocardial damage.
Collapse
Affiliation(s)
| | | | - Ana González-Suárez
- Translational Medical Device Lab, School of Medicine, University of Galway, Ireland; IBIO, Escuela Superior de Ingeniería, Ciencia y Tecnología, Universidad Internacional de Valencia, Valencia, Spain.
| |
Collapse
|
2
|
Reddy VY, Anter E, Peichl P, Rackauskas G, Petru J, Funasako M, Koruth JS, Marinskis G, Turagam M, Aidietis A, Kautzner J, Natale A, Neuzil P. First-in-Human Clinical Series of a Novel Conformable Large-Lattice Pulsed Field Ablation Catheter for Pulmonary Vein Isolation. Europace 2024:euae090. [PMID: 38584468 DOI: 10.1093/europace/euae090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Accepted: 04/03/2024] [Indexed: 04/09/2024] Open
Abstract
BACKGROUND/AIMS Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8-Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 secs per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2 and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. RESULTS At three centers, PVI was performed by five operators in 85 patients using PULSE1 (n=30), PULSE2 (n=20), and PULSE3 (n=35). Acute PVI was achieved in 100% of PVs using 3.9±1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5±21.6, 10.0 ± 6.0, 19.1±9.3 and 5.7±3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION PVI utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.
Collapse
Affiliation(s)
- Vivek Y Reddy
- Icahn School of Medicine at Mount Sinai, New York, NY
- Homolka Hospital, Prague, Czech Republic
| | | | - Petr Peichl
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | | | - Jan Petru
- Homolka Hospital, Prague, Czech Republic
| | | | | | | | - Mohit Turagam
- Icahn School of Medicine at Mount Sinai, New York, NY
| | | | - Josef Kautzner
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, Austin, Tx
- Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome
| | | |
Collapse
|
3
|
Audiat C, Della Rocca DG, de Asmundis C, Chierchia GB. Interference from lobe-and-disk left atrial appendage occluder affecting left superior pulmonary vein pulsed field ablation. Heart Rhythm 2024:S1547-5271(24)02303-8. [PMID: 38574790 DOI: 10.1016/j.hrthm.2024.03.1808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 03/24/2024] [Indexed: 04/06/2024]
Affiliation(s)
- Charles Audiat
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium
| | - Domenico Giovanni Della Rocca
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium
| | - Gian Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium
| |
Collapse
|
4
|
Aldaas OM, Malladi C, Han FT, Hoffmayer KS, Krummen D, Ho G, Raissi F, Birgersdotter-Green U, Feld GK, Hsu JC. Pulsed field ablation versus thermal energy ablation for atrial fibrillation: a systematic review and meta-analysis of procedural efficiency, safety, and efficacy. J Interv Card Electrophysiol 2024; 67:639-648. [PMID: 37855992 PMCID: PMC11016003 DOI: 10.1007/s10840-023-01660-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 10/02/2023] [Indexed: 10/20/2023]
Abstract
BACKGROUND Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.
Collapse
Affiliation(s)
- Omar Mahmoud Aldaas
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Chaitanya Malladi
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Frederick T Han
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Kurt S Hoffmayer
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - David Krummen
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Gordon Ho
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Farshad Raissi
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Ulrika Birgersdotter-Green
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Gregory K Feld
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA
| | - Jonathan C Hsu
- Division of Cardiac Electrophysiology at the University of California San Diego Health System, 9452 Medical Center Drive, La Jolla, CA, 92037, USA.
- Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine, University of CA - San Diego, 9452 Medical Center Drive, 3rd Floor, Room 3E-417, La Jolla, CA, 92037, USA.
| |
Collapse
|
5
|
Metzner A, Rottner L, Moser F, My I, Lemoine M, Wenzel JP, Obergassel J, Ismaili D, Schäfer S, Kirchhof P, Ouyang F, Reissmann B, Rillig A. A novel platform allowing for pulsed field and radiofrequency ablation: First commercial atrial fibrillation ablation procedures worldwide with and without general anesthesia. Heart Rhythm 2024; 21:497-498. [PMID: 38215807 DOI: 10.1016/j.hrthm.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/02/2024] [Accepted: 01/06/2024] [Indexed: 01/14/2024]
Affiliation(s)
- Andreas Metzner
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany.
| | - Laura Rottner
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Fabian Moser
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Ilaria My
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Marc Lemoine
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Jan Per Wenzel
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Julius Obergassel
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Djemail Ismaili
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Sarina Schäfer
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Paulus Kirchhof
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Feifan Ouyang
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Bruno Reissmann
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| | - Andreas Rillig
- University Heart and Vascular Center Hamburg-Eppendorf, Eppendorf, Germany
| |
Collapse
|
6
|
Chaumont C, McDonnell E, Boveda S, Savoure A, Rollin A, Combes S, Al Hamoud R, Mandel F, Zeriouh S, Eltchaninoff H, Maury P, Anselme F. Prospective 1-year results of atrial fibrillation ablation using the pentaspline pulsed field ablation catheter: The initial French experience. Arch Cardiovasc Dis 2024; 117:249-254. [PMID: 38494400 DOI: 10.1016/j.acvd.2024.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 12/29/2023] [Accepted: 01/03/2024] [Indexed: 03/19/2024]
Abstract
BACKGROUND Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.
Collapse
Affiliation(s)
- Corentin Chaumont
- Department of Cardiology, CHU de Rouen, 76000 Rouen, France; University of Rouen Normandie, Inserm EnVI UMR 1096, 76000 Rouen, France
| | | | - Serge Boveda
- Heart Rhythm Management Department, Clinique Pasteur, 31076 Toulouse, France; Brussels University (VUB), 1050 Brussels, Belgium
| | - Arnaud Savoure
- Department of Cardiology, CHU de Rouen, 76000 Rouen, France
| | - Anne Rollin
- Department of Cardiology, CHU de Toulouse, 31300 Toulouse, France
| | - Stephane Combes
- Heart Rhythm Management Department, Clinique Pasteur, 31076 Toulouse, France
| | | | - Franck Mandel
- Department of Cardiology, CHU de Toulouse, 31300 Toulouse, France
| | - Sarah Zeriouh
- Heart Rhythm Management Department, Clinique Pasteur, 31076 Toulouse, France
| | - Helene Eltchaninoff
- Department of Cardiology, CHU de Rouen, 76000 Rouen, France; University of Rouen Normandie, Inserm EnVI UMR 1096, 76000 Rouen, France
| | - Philippe Maury
- Department of Cardiology, CHU de Toulouse, 31300 Toulouse, France; I2MC, Inserm UMR 1297, 31432 Toulouse, France
| | - Frederic Anselme
- Department of Cardiology, CHU de Rouen, 76000 Rouen, France; University of Rouen Normandie, Inserm EnVI UMR 1096, 76000 Rouen, France.
| |
Collapse
|
7
|
Farnir F, Chaldoupi SM, Farnir F, Schotten U, Vernooy K, Luermans J, Linz D. Focal point-by-point biphasic monopolar pulsed field ablation for posterior wall isolation. Europace 2024; 26:euae077. [PMID: 38517287 PMCID: PMC11017520 DOI: 10.1093/europace/euae077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 03/19/2024] [Indexed: 03/23/2024] Open
Affiliation(s)
- Florent Farnir
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| | - Sevasti-Maria Chaldoupi
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| | - Frédéric Farnir
- Department of Biostatistics and Bioinformatics, FARAH, Faculty of Veterinary Medicine, University of Liege, Liege, Belgium
| | - Ulrich Schotten
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| | - Justin Luermans
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| | - Dominik Linz
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark
| |
Collapse
|
8
|
Wang Y, Lai HL, Chen Q, Liu H, Liu QM, Huang WB, Tao Y, Xiong Q, Zhou N, Zhao C, Qiu J, Xu Z, Wang DW. Application of a circular-shaped pulsed field ablation catheter with magnetic sensors for pulmonary vein isolation: a multi-centre clinical study report. Europace 2024; 26:euae068. [PMID: 38584395 PMCID: PMC10999647 DOI: 10.1093/europace/euae068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 02/24/2024] [Indexed: 04/09/2024] Open
Abstract
AIMS A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.
Collapse
Affiliation(s)
- Yan Wang
- Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China
| | - Heng Li Lai
- Division of Cardiology, Jiangxi Provincial People’s Hospital, Nanchang, China
| | - Qi Chen
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Hao Liu
- Division of Cardiology, The Second Affiliated Hospital of Guangxi Medical University, Nanning, China
| | - Qi Ming Liu
- Division of Cardiology, Xiamen University Affiliated Zhongshan Hospital, Xiamen, China
| | - Wei Bin Huang
- Division of Cardiology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Yu Tao
- Division of Cardiology, Jiangxi Provincial People’s Hospital, Nanchang, China
| | - Qingmei Xiong
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang, China
| | - Ning Zhou
- Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China
| | - Chunxia Zhao
- Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China
| | - Jie Qiu
- Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China
| | - Ziqin Xu
- Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China
| | - Dao Wen Wang
- Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China
| |
Collapse
|
9
|
Gunawardene MA, Harloff T, Jularic M, Dickow J, Wahedi R, Anwar O, Wohlmuth P, Gessler N, Hartmann J, Willems S. Contemporary catheter ablation of complex atrial tachycardias after prior atrial fibrillation ablation: pulsed field vs. radiofrequency current energy ablation guided by high-density mapping. Europace 2024; 26:euae072. [PMID: 38513110 PMCID: PMC11034699 DOI: 10.1093/europace/euae072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 03/12/2024] [Indexed: 03/23/2024] Open
Abstract
AIMS Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44 min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6 min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.
Collapse
Affiliation(s)
- Melanie A Gunawardene
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
- DZHK (German Center for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Potsdamer Strasse 58, 10785 Berlin, Germany
| | - Tim Harloff
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
| | - Mario Jularic
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
| | - Jannis Dickow
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
- DZHK (German Center for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Potsdamer Strasse 58, 10785 Berlin, Germany
| | - Rahin Wahedi
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
| | - Omar Anwar
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
| | - Peter Wohlmuth
- Asklepios Proresearch Research Insitute, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
| | - Nele Gessler
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
- DZHK (German Center for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Potsdamer Strasse 58, 10785 Berlin, Germany
- Asklepios Proresearch Research Insitute, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
| | - Jens Hartmann
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
| | - Stephan Willems
- Department of Cardiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
- Semmelweis University Budapest Hungary, Asklepios Campus Hamburg, Lohmuehlenstrasse 5, 20099 Hamburg and Ülloi ut 26, 1085 Budapest
- DZHK (German Center for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Potsdamer Strasse 58, 10785 Berlin, Germany
| |
Collapse
|
10
|
Brešković T, Lisica L, Jurišić Z, Petrović D, Sikirić I, Metličić V, Anić A. Ablation of accessory pathways in different anatomic locations using focal pulsed field ablation. Heart Rhythm 2024:S1547-5271(24)00275-3. [PMID: 38499129 DOI: 10.1016/j.hrthm.2024.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/05/2024] [Indexed: 03/20/2024]
Abstract
BACKGROUND Ablation of accessory pathways (APs) is the cornerstone for treatment of patients with Wolff-Parkinson-White syndrome and manifestation of atrioventricular reentrant tachycardia. Pulsed field ablation (PFA) is a new type of nonthermal energy source delivered to the underlying tissue via the ablation catheter and used for ablation of arrhythmic substrates. OBJECTIVE The purpose of this study was to determine the efficiency and long-term outcome of ablation of APs of different localizations using a focal pulsed electrical field. METHODS Electrophysiological study was performed in patients with indication for AP ablation. An ablation catheter was used to map the position of AP insertion. Pulsed electric field was delivered through a standard ablation catheter. In left-sided APs, the first ablation attempt was within the coronary sinus (CS). Patient follow-up was scheduled 1-3 months after the ablation. Additional check-up was performed after 6 and 12 months. RESULTS Fourteen 14 patients (3 pediatric) were treated. Termination of AP conduction was achieved in all procedures. The cohort consisted of 3 right free wall, 3 posteroseptal, and 8 left-sided APs. Ablation through CS was successfully used in 7 of 8 patients with left-sided APs. No complications were reported. Median follow-up was 5.5 months. Conduction recurrence through AP was documented in 1 patient. CONCLUSION Focal PFA for AP shows promising results in terms of efficacy and safety. A high rate of successful termination of left-sided APs by ablation within CS may represent a new standard approach. The safety and efficacy profile of PFA seems to be transferable to the pediatric population.
Collapse
Affiliation(s)
- Toni Brešković
- Department of Cardiology, University Hospital Center Split, Split, Croatia.
| | - Lucija Lisica
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| | - Zrinka Jurišić
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| | - Davor Petrović
- Division of Cardiology, Department of Pediatrics, University Hospital Center Split, Split, Croatia
| | - Ivan Sikirić
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| | - Vitomir Metličić
- Division of Cardiology, Department of Pediatrics, University Hospital Center Split, Split, Croatia
| | - Ante Anić
- Department of Cardiology, University Hospital Center Split, Split, Croatia
| |
Collapse
|
11
|
Banai A, Chorin E, Schwartz AL, Levi Y, Sliman H, Feder O, Viskin D, Viskin S, Banai S, Rosso R. Pulsed field ablation prevents left atrial restrictive physiology after posterior wall isolation in patients with persistent atrial fibrillation. Heart Rhythm 2024:S1547-5271(24)00240-6. [PMID: 38460752 DOI: 10.1016/j.hrthm.2024.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/04/2024] [Accepted: 03/04/2024] [Indexed: 03/11/2024]
Affiliation(s)
- Ariel Banai
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Ehud Chorin
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Arie Lorin Schwartz
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Yuval Levi
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Hend Sliman
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Omri Feder
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Dana Viskin
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Sami Viskin
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Shmuel Banai
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel
| | - Raphael Rosso
- Tel Aviv Sourasky Medical Center and Tel Aviv University, School of Medicine, Tel Aviv, Israel.
| |
Collapse
|
12
|
De Becker B, El Haddad M, De Smet M, François C, Tavernier R, le Polain de Waroux JB, Knecht S, Duytschaever M. Procedural performance and outcome after pulsed field ablation for pulmonary vein isolation: comparison with a reference radiofrequency database. Eur Heart J Open 2024; 4:oeae014. [PMID: 38487367 PMCID: PMC10939121 DOI: 10.1093/ehjopen/oeae014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/16/2024] [Accepted: 02/22/2024] [Indexed: 03/17/2024]
Abstract
Aims Pulsed field ablation (PFA) is a promising ablation technique for pulmonary vein isolation (PVI) with appealing advantages over radiofrequency (RF) including speed, tissue selectivity, and the promise of enhanced durability. In this study, we determine the procedural performance, efficacy, safety, and durability of PFA and compare its performance with a dataset of optimized RF ablation. Methods and results After propensity score matching, we compared 161 patients who received optimized RF-guided PVI in the PowerPlus study (CLOSE protocol) with 161 patients undergoing PFA-guided PVI for paroxysmal or persistent atrial fibrillation (AF; pentaspline basket catheter). The median age was 65 years with 78% paroxysmal AF in the PFA group (comparable characteristics in the RF group). Pulsed field ablation-guided PVI was obtained in all patients with a procedure time of 47 min (vs. 71 min in RF, P < 0.0001) and a fluoroscopy time of 15 min (vs. 11 min in RF, P < 0.0001). One serious adverse event [transient ischaemic attack] occurred in a patient with thrombocytosis (0.6 vs. 0% in RF). During the 6-month follow-up, 24 and 27 patients experienced a recurrence with 20 and 11 repeat procedures in the PFA and the RF groups, respectively (P = 0.6 and 0.09). High-density mapping revealed a status of 4 isolated veins in 7/20 patients in the PFA group and in 2/11 patients in the RF group (35 vs. 18%, P = 0.3). Conclusion Pulsed field ablation fulfils the promise of offering a short and safe PVI procedure, even when compared with optimized RF in experienced hands. Pulmonary vein reconnection is the dominant cause of recurrence and tempers the expectation of a high durability rate with PFA.
Collapse
Affiliation(s)
- Benjamin De Becker
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| | - Milad El Haddad
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| | - Maarten De Smet
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| | - Clara François
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| | - Rene Tavernier
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| | | | - Sébastien Knecht
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| | - Mattias Duytschaever
- Department of Cardiology, AZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium
| |
Collapse
|
13
|
Metzner A, Fiala M, Vijgen J, Ouss A, Gunawardene M, Hansen J, Kautzner J, Schmidt B, Duytschaever M, Reichlin T, Blaauw Y, Sommer P, Vanderper A, Achyutha AB, Johnson M, Raybuck JD, Neuzil P. Long-term outcomes of the pentaspline pulsed-field ablation catheter for the treatment of paroxysmal atrial fibrillation: results of the prospective, multicentre FARA-Freedom Study. Europace 2024; 26:euae053. [PMID: 38385529 PMCID: PMC10932745 DOI: 10.1093/europace/euae053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 02/16/2024] [Indexed: 02/23/2024] Open
Abstract
AIMS Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).
Collapse
Affiliation(s)
- Andreas Metzner
- Klinik für Kardiologie, Universitätsklinikum Hamburg-Eppendorf, Martinistraße 52, Gebäude Ost 70, 20246 Hamburg, Germany
| | - Martin Fiala
- Department of Internal Medicine and Cardiology, University Hospital Brno, Brno, Czech Republic
| | - Johan Vijgen
- Division of Electrophysiology, Jessa Ziekenhuis, Hasselt, Belgium
| | - Alexandre Ouss
- Department of Cardiology, Catharina Ziekenhuis, Eindhoven, The Netherlands
| | - Melanie Gunawardene
- Department of Cardiology and Internal Intensive Care Medicine, Asklepios Klinik St Georg, Hamburg, Germany
| | - Jim Hansen
- Department of Cardiology, Gentofte Hospital, Hellerup, Denmark
| | - Josef Kautzner
- Department of Cardiology, Institute for Clinical and Experimental Medicine-IKEM, Prague, Czech Republic
| | - Boris Schmidt
- Cardioangiologisches Centrum Bethanien, Academic Teaching Hospital of Goethe University of Frankfurt, Frankfurt, Germany
| | | | - Tobias Reichlin
- Department of Rhythmology and Cardiac Electrophysiology, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland
| | - Yuri Blaauw
- Department of Cardiology, University Medical Center, Groningen, The Netherlands
| | - Philipp Sommer
- Department of Cardiology and Rhythmology, Hdz Nrw, Bad Oeynhausen, Gemany
| | | | | | | | | | - Petr Neuzil
- Department of Cardiology, Nemocnice Na Homolce Hospital, Prague, Czech Republic
| |
Collapse
|
14
|
Maccioni S, Sharma R, Lee DD, Haltner A, Khanna R, Vijgen J. Comparative Safety of Pulsed Field Ablation and Cryoballoon Ablation Technologies for Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation: A Critical Literature Review and Indirect Treatment Comparison. Adv Ther 2024; 41:932-944. [PMID: 38185778 PMCID: PMC10879347 DOI: 10.1007/s12325-023-02765-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 12/06/2023] [Indexed: 01/09/2024]
Abstract
INTRODUCTION Cryoballoon ablation (CBA) is a standard catheter ablation technology with demonstrated clinical effectiveness for the treatment of paroxysmal atrial fibrillation (PAF); however, it can be associated with major adverse events, including phrenic nerve paralysis. Pulsed field ablation (PFA) is a novel, minimally thermal technology with comparable effectiveness and low safety risk. This study aimed to compare the safety profiles of PFA and CBA through critical analyses of the literature and indirect treatment comparisons. METHODS Studies were identified by searching the MEDLINE database and the Clinicaltrials.gov registry. Registered clinical trials and/or Food and Drug Administration Investigation Device Exemption (FDA IDE) studies evaluating PFA or CBA in adult patients with drug-refractory PAF between January 2008 and March 2023 were selected. Comparative safety between PFA and CBA was assessed for major and prespecified adverse events. Indirect comparisons were conducted using the proportion of patients experiencing adverse events and confirmed with single-arm meta-analyses and sensitivity analyses. RESULTS Data were extracted from three PFA publications including a total of 497 patients and six CBA studies including a total of 1113 patients. The analysis revealed that PFA was associated with significantly lower risk of major adverse events {risk difference - 4.3% [95% confidence interval (CI) - 5.8, - 2.8]; risk ratio 0.16 [95% CI 0.07, 0.45]} and prespecified adverse events [risk difference - 2.5% (95% CI - 4.4, - 0.5); risk ratio 0.53 (95% CI 0.31, 0.96)]. Meta-analyses confirmed the lower rate of major adverse events for PFA [0.4% (95% CI 0.0, 1.3)] vs. CBA [5.6% (95% CI 2.6, 8.6)] and prespecified adverse events for PFA [2.7% (95% CI 1.2, 4.1)] vs. CBA [5.8% (95% CI 2.7, 9.0)]. Sensitivity analyses exploring heterogeneity across studies confirmed robustness of the main analyses. CONCLUSION The findings of this study show that PFA has a more favorable safety profile than CBA, with significantly lower risks of major and prespecified adverse events. These indirect comparisons help contextualize the safety of PFA compared to CBA for the treatment of drug-refractory PAF in the absence of head-to-head studies.
Collapse
Affiliation(s)
- Sonia Maccioni
- Johnson and Johnson Medical Devices, Franchise Health Economics and Market Access, Irvine, CA, 92618, USA.
| | - Reecha Sharma
- Johnson and Johnson Medical Devices, Clinical Research, Irvine, CA, 92618, USA
| | | | | | - Rahul Khanna
- Medical Device Epidemiology and Real-World Data Sciences, Johnson and Johnson, New Brunswick, NJ, USA
| | - Johan Vijgen
- Cardiology Department, Jessa Hospitals, Hasselt, Belgium
| |
Collapse
|
15
|
Ruwald MH, Haugdal M, Worck R, Johannessen A, Hansen ML, Sørensen SK, Hansen J. Characterization of durability and reconnection patterns at time of repeat ablation after single-shot pulsed field pulmonary vein isolation. J Interv Card Electrophysiol 2024; 67:379-387. [PMID: 37776356 PMCID: PMC10902076 DOI: 10.1007/s10840-023-01655-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 09/17/2023] [Indexed: 10/02/2023]
Abstract
BACKGROUND Pulsed field ablation (PFA) is a novel method of cardiac ablation where there is insufficient knowledge on the durability and reconnection patterns after pulmonary vein isolation (PVI). The aim of this study was to characterize the electrophysiological findings at time of repeat procedure in real-world atrial fibrillation (AF) patients. METHODS Patients who underwent a repeat procedure (n=26) for symptomatic recurrent arrhythmias after index first-time treatment with single-shot PFA PVI (n=266) from July 2021 to June 2023 were investigated with 3D high-density mapping and ad-hoc re-ablation by radiofrequency or focal PFA. RESULTS Index indication for PVI was persistent AF in 17 (65%) patients. The mean time to repeat procedure was 292 ± 119 days. Of the 26 patients (104 veins), complete durable PVI was observed in 11/26 (42%) with a durable vein isolation rate of 72/104 (69%). Two patients (8%) had all four veins reconnected. The posterior wall was durably isolated in 4/5 (80%) of the cases. The predominant arrhythmia mechanism was AF in 17/26 (65%) patients and regular atrial tachycardia (AT) in 9/26 (35%). Reconnection was observed 9/26 (35%) in right superior, 11/26 (42%) in right inferior, 7/26 (27%) in left superior, 5/26 (19%) in left inferior, p=0.31 between veins. The gaps were significantly clustered in the right-sided anterior carina compared to other regions (P=0.009). CONCLUSIONS Durable PVI was observed in less than half of the patients at time of repeat procedure. No significant difference in PV reconnection pattern was observed, but the gap location was preferentially located at the anterior aspects of the right-sided PVs. Predominant recurrence was AF. More data is needed to establish lesion formation and durability and AT circuits after PFA.
Collapse
Affiliation(s)
- Martin H Ruwald
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.
| | - Martin Haugdal
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Rene Worck
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Arne Johannessen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Morten Lock Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Samuel K Sørensen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Jim Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| |
Collapse
|
16
|
Du Y, Ma S, Yue P, Xu Y, Wen Y, Ji M, He L, Liao D. Comparing the effects of pulsed and radiofrequency catheter ablation on quality of life, anxiety, and depression of patients with paroxysmal supraventricular tachycardia: a single-center, randomized, single-blind, standard-controlled trial. Trials 2024; 25:146. [PMID: 38402192 PMCID: PMC10893749 DOI: 10.1186/s13063-024-07971-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 02/05/2024] [Indexed: 02/26/2024] Open
Abstract
BACKGROUND Radiofrequency catheter ablation (RFCA) may lead to decreased quality of life (QOL) and increased anxiety and depression in patients with paroxysmal supraventricular tachycardia (PSVT), possibly due to the lack of selectivity of the ablation tissue and the long ablation time. In recent years, pulsed field ablation (PFA) has been used for the first time in China to treat PSVT patients because of its ability to ablate abnormal tissue sites in a precise and transient manner. This study was conducted to compare the effects of PFA and RFCA on QOL and psychological symptoms of PSVT patients. METHODS We have designed a single-center, randomized, single-blind, standard-controlled trial. A total of 50 participants who met the eligibility criteria would be randomly allocated into the PFA group or RFCA group in a 1:1 ratio. All participants were assessed using the 36-Item Short-Form Health Survey (SF-36) and the Hospital Anxiety and Depression Scale (HADS) at pre-procedure (T0), post-procedure (T1), and 3 months post-procedure (T2). The SPSS 21.0 software was used to analyze the data through Wilcoxon and Fisher's exact tests and repeated measures ANOVA. RESULTS Twenty-five in the PFA group and 24 in the RFCA group completed the trial. SF-36: (1) Between-group comparison: At T1, PFA group had significantly higher SF-36 scores on physiological function (PF) and general health (GH) than RFCA group, with a treatment difference of 5.61 points and 18.51 points(P < 0.05). (2) Within-group comparison: We found that in the PFA and RFCA groups, T2 showed significant improvement in the remaining 6 subscales of the SF-36 scale compared to T1 and T0 (P < 0.05), except for body pain (BP) and social function (SF) scores. HADS: (1) Between-group comparison: no significant difference (P > 0.05). (2) Within-group comparison: The HADS scores of the PFA and RFCA groups were statistically significant at T2 compared to T0 and T1 (P < 0.05). CONCLUSIONS Our study provided new and meaningful evidence that PFA was effective in significantly improving QOL and decreasing anxiety and depression in PFA patients. TRIAL REGISTRATION Chinese Clinical Trial Registry, ChiCTR2200060272.
Collapse
Affiliation(s)
- Ying Du
- Department of Orthopedic Surgery, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
- Trauma Center, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
| | - Shanshan Ma
- Department of Cardiology, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
| | - Pan Yue
- Department of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, China
| | - Ying Xu
- Department of Cardiology, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
| | - Ya Wen
- Department of Cardiology, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
| | - Mingzhu Ji
- Department of Cardiology, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
| | - Lingxiao He
- Department of Orthopedic Surgery, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
- Trauma Center, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
| | - Dengbin Liao
- Department of Orthopedic Surgery, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China.
- Trauma Center, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China.
| |
Collapse
|
17
|
Eberl AS, Manninger M, Rohrer U, Scherr D. Prolonged asystole after conversion to sinus rhythm during pulmonary vein isolation with pulsed field ablation: A case report. HeartRhythm Case Rep 2024; 10:146-150. [PMID: 38404973 PMCID: PMC10885723 DOI: 10.1016/j.hrcr.2023.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2024] Open
Affiliation(s)
- Anna-Sophie Eberl
- Division of Cardiology, Department of Medicine, Medical University of Graz, Graz, Austria
| | - Martin Manninger
- Division of Cardiology, Department of Medicine, Medical University of Graz, Graz, Austria
| | - Ursula Rohrer
- Division of Cardiology, Department of Medicine, Medical University of Graz, Graz, Austria
| | - Daniel Scherr
- Division of Cardiology, Department of Medicine, Medical University of Graz, Graz, Austria
| |
Collapse
|
18
|
Mansour M, Gerstenfeld EP, Patel C, Natale A, Whang W, Cuoco FA, Mountantonakis SE, Gibson DN, Harding JD, Holland SK, Achyutha AB, Schneider CW, Mugglin AS, Albrecht EM, Stein KM, Lehmann JW, Reddy VY. Pulmonary vein narrowing after pulsed field versus thermal ablation. Europace 2024; 26:euae038. [PMID: 38305503 PMCID: PMC10875916 DOI: 10.1093/europace/euae038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 01/26/2024] [Indexed: 02/03/2024] Open
Abstract
AIMS When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.
Collapse
Affiliation(s)
- Moussa Mansour
- Massachusetts General Hospital, GRB 815, 55 Fruit Street, Boston, MA, USA
| | - Edward P Gerstenfeld
- Section of Cardiac Electrophysiology, University of California San Francisco, San Francisco, CA, USA
| | - Chinmay Patel
- Heart and Vascular Institute, University of Pittsburgh Medical Center Pinnacle, Harrisburg, PA, USA
| | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, St. David’s Medical Center, Austin, TX, USA
- Case Western Reserve University, Cleveland, OH, USA
| | - William Whang
- Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, New York, NY, USA
| | | | | | - Douglas N Gibson
- Scripps Clinic and Prebys Cardiovascular Institute, San Diego, CA, USA
| | | | | | - Anitha B Achyutha
- Department of Electrophysiology, Boston Scientific Corporation, Menlo Park, CA, USA
| | | | | | - Elizabeth M Albrecht
- Department of Electrophysiology, Boston Scientific Corporation, St. Paul, MN, USA
| | - Kenneth M Stein
- Department of Electrophysiology, Boston Scientific Corporation, St. Paul, MN, USA
| | | | - Vivek Y Reddy
- Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, New York, NY, USA
| |
Collapse
|
19
|
Sousonis V, Voglimacci-Stephanopoli Q, Zeriouh S, Boveda S, Albenque JP. Pulsed field ablation of spatiotemporal electrogram dispersion following pulmonary vein isolation and left atrial linear lesions for persistent atrial fibrillation: a case report. Eur Heart J Case Rep 2024; 8:ytae085. [PMID: 38405199 PMCID: PMC10894002 DOI: 10.1093/ehjcr/ytae085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 12/10/2023] [Accepted: 02/07/2024] [Indexed: 02/27/2024]
Abstract
Background Ablation of persistent atrial fibrillation (AF) remains challenging, with atrial substrate modification often being performed as an adjunct to pulmonary vein isolation (PVI). Pulsed field ablation (PFA) is a novel ablation modality that carries a favourable safety profile, which could facilitate complex procedures. Case summary We present the case of a 60-year-old male undergoing catheter ablation for symptomatic persistent AF. The procedure was performed with the Farapulse™ PFA system in a stepwise manner, including PVI and linear lesions for the isolation of the posterior left atrial wall and the ablation of the mitral isthmus. The final step of the procedure included the ablation of areas exhibiting spatiotemporal electrogram dispersion, identified with the help of artificial intelligence-based software (VX1, Volta Medical) in both atria. Sinus rhythm was restored after the abolition of an electrogram dispersion zone in the right atrium. The procedure was carried out without any complications. Discussion Complex ablation procedures for persistent AF can be successfully performed with PFA. In the context of such extensive ablation strategies, PFA is an attractive energy source, given its non-thermal nature that is known to prevent damage to surrounding tissue and result in less chronic fibrosis. However, caution should be exercised to avoid excessive ablation when using the currently available multispline PFA catheter, as it may inadvertently target adjacent areas of healthy myocardium.
Collapse
Affiliation(s)
- Vasileios Sousonis
- Heart Rhythm Management Department, Clinique Pasteur, 45 Avenue de Lombez, 31300 Toulouse, France
| | | | - Sarah Zeriouh
- Heart Rhythm Management Department, Clinique Pasteur, 45 Avenue de Lombez, 31300 Toulouse, France
| | - Serge Boveda
- Heart Rhythm Management Department, Clinique Pasteur, 45 Avenue de Lombez, 31300 Toulouse, France
| | - Jean Paul Albenque
- Heart Rhythm Management Department, Clinique Pasteur, 45 Avenue de Lombez, 31300 Toulouse, France
| |
Collapse
|
20
|
Jacobs Iv EJ, Campelo SN, Charlton A, Altreuter S, Davalos RV. Characterizing reversible, irreversible, and calcium electroporation to generate a burst-dependent dynamic conductivity curve. Bioelectrochemistry 2024; 155:108580. [PMID: 37788520 DOI: 10.1016/j.bioelechem.2023.108580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 09/20/2023] [Accepted: 09/24/2023] [Indexed: 10/05/2023]
Abstract
The relationships between burst number, reversible, irreversible, and calcium electroporation have not been comprehensively evaluated in tumor tissue-mimics. Our findings indicate that electroporation effects saturate with a rate constant (τ) of 20 bursts for both conventional and high frequency waveforms (R2 > 0.88), with the separation between reversible and irreversible electroporation thresholds converging at 50 bursts. We find the lethal thresholds for calcium electroporation are statistically similar to reversible electroporation (R2 > 0.99). We then develop a burst-dependent dynamic conductivity curve that now incorporates electroporation effects due to both the electric field magnitude and burst number. Simulated ablation and thermal damage volumes vary significantly between finite element models using either the conventional or new burst-dependent dynamic conductivity curve (p < 0.05). Lastly, for clinically relevant protocols, thermal damage is indicated to not begin until 50 bursts, with maximum nonthermal ablation volumes at 100 bursts (1.5-13% thermal damage by volume). We find that >100 bursts generated negligible increases in ablation volumes with 40-70% thermal damage by volume at 300 bursts. Our results illustrate the need for considering burst number in minimizing thermal damage, choosing adjuvant therapies, and in modeling electroporation effects at low burst numbers.
Collapse
Affiliation(s)
- Edward J Jacobs Iv
- Bioelectromechanical Systems Laboratory, Virginia Tech - Wake Forest School of Biomedical Engineering, Blacksburg, VA, USA; Bioelectromechanical Systems Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech - Emory University, Atlanta, GA, USA
| | - Sabrina N Campelo
- Bioelectromechanical Systems Laboratory, Virginia Tech - Wake Forest School of Biomedical Engineering, Blacksburg, VA, USA
| | - Alyssa Charlton
- Bioelectromechanical Systems Laboratory, Virginia Tech - Wake Forest School of Biomedical Engineering, Blacksburg, VA, USA
| | - Sara Altreuter
- Bioelectromechanical Systems Laboratory, Virginia Tech - Wake Forest School of Biomedical Engineering, Blacksburg, VA, USA
| | - Rafael V Davalos
- Bioelectromechanical Systems Laboratory, Virginia Tech - Wake Forest School of Biomedical Engineering, Blacksburg, VA, USA; Bioelectromechanical Systems Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech - Emory University, Atlanta, GA, USA.
| |
Collapse
|
21
|
Del Monte A, Della Rocca DG, Pannone L, Vetta G, Cespón Fernández M, Marcon L, Doundoulakis I, Mouram S, Audiat C, Zeriouh S, Monaco C, Al Housari M, Betancur A, Mené R, Iacopino S, Sorgente A, Bala G, Ströker E, Sieira J, Almorad A, Sarkozy A, Boveda S, de Asmundis C, Chierchia GB. Pulsed field ablation of the right superior pulmonary vein prevents vagal responses via anterior right ganglionated plexus modulation. Heart Rhythm 2024:S1547-5271(24)00094-8. [PMID: 38290688 DOI: 10.1016/j.hrthm.2024.01.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 01/19/2024] [Accepted: 01/22/2024] [Indexed: 02/01/2024]
Abstract
BACKGROUND Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.
Collapse
Affiliation(s)
- Alvise Del Monte
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Domenico Giovanni Della Rocca
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Luigi Pannone
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Giampaolo Vetta
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - María Cespón Fernández
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Lorenzo Marcon
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Ioannis Doundoulakis
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Sahar Mouram
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Charles Audiat
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Sarah Zeriouh
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France
| | - Cinzia Monaco
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Maysam Al Housari
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Andrés Betancur
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France
| | - Roberto Mené
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France
| | - Saverio Iacopino
- Electrophysiology Unit, GVM Care & Research, Maria Cecilia Hospital, Cotignola, Italy
| | - Antonio Sorgente
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Erwin Ströker
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Alexandre Almorad
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Andrea Sarkozy
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Serge Boveda
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.
| | - Gian-Battista Chierchia
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| |
Collapse
|
22
|
Rattka M, Mavrakis E, Vlachopoulou D, Rudolph I, Kohn C, Bohnen J, Yahsaly L, Siebermair J, Wakili R, Jungen C, Rassaf T, Mathew S. Pulsed field ablation and cryoballoon ablation for pulmonary vein isolation: insights on efficacy, safety and cardiac function. J Interv Card Electrophysiol 2024:10.1007/s10840-024-01748-4. [PMID: 38273159 DOI: 10.1007/s10840-024-01748-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/10/2024] [Indexed: 01/27/2024]
Abstract
BACKGROUND Pulmonary vein isolation (PVI) has become the cornerstone treatment of atrial fibrillation (AF). While in cryoablation cell damage is caused by thermal effects, lately, pulsed field ablation (PFA) has been established as a novel non-thermal tissue-specific ablation modality for PVI. However, data comparing outcomes of patients undergoing either PFA or cryoballoon ablation (CBA) for primary PVI are sparse. METHODS Consecutive patients with AF undergoing PVI by either CBA or PFA were included in the analysis. The primary outcome was the time to AF/AT recurrence. For secondary outcomes, clinical and periprocedural parameters were compared. RESULTS In total, outcomes of 141 AF patients treated by PFA (94 patients) or CBA (47 patients) were compared. After 365 days, 70% of patients in the PFA group and 61% of patients in the CBA group were free from AF/AT (HR 1.35, 95% CI 0.60-3.00; p = 0.470). No deaths occurred. While symptoms alleviated in both groups, only after PFA, we observed significant improvement of left atrial volume index (PFA group baseline: 40 [31;62] ml/m2, PFA group follow-up: 35 [29;49] ml/m2; p = 0.015), NT-pro BNP levels (PFA group baseline: 1106 ± 2479 pg/ml, PFA group follow-up: 1033 ± 1742 pg/ml; p = 0.048), and left ventricular ejection fraction (LVEF) (PFA group baseline: 55 [48;60] %, PFA group follow-up: 58 [54;63] %; p = 0.006). PVI by PFA was the only independent predictor of LVEF improvement. CONCLUSION In our study, we show that CBA and PFA for PVI are of similar efficacy when it comes to AF recurrence. However, our findings suggest that PFA rather than CBA might induce left atrial reverse remodeling thereby contributing to left ventricular systolic function.
Collapse
Affiliation(s)
- Manuel Rattka
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Evangelos Mavrakis
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Dimitra Vlachopoulou
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Isabel Rudolph
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Christina Kohn
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Jan Bohnen
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Loubna Yahsaly
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Johannes Siebermair
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
- Krankenhaus Goettlicher Heiland, Vienna, Austria
| | - Reza Wakili
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
- Department of Cardiology and Vascular Medicine, University Hospital Frankfurt, Goethe-University Frankfurt, Frankfurt am Main, Germany
| | - Christiane Jungen
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Tienush Rassaf
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Shibu Mathew
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany.
| |
Collapse
|
23
|
Jacobs EJ, Aycock KN, Santos PP, Tuohy JL, Davalos RV. Rapid estimation of electroporation-dependent tissue properties in canine lung tumors using a deep neural network. Biosens Bioelectron 2024; 244:115777. [PMID: 37924653 DOI: 10.1016/j.bios.2023.115777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 10/08/2023] [Accepted: 10/20/2023] [Indexed: 11/06/2023]
Abstract
The efficiency of electroporation treatments depends on the application of a critical electric field over the targeted tissue volume. Both the electric field and temperature distribution strongly depend on the tissue-specific electrical properties, which both differ between patients in healthy and malignant tissues and change in an electric field-dependent manner from the electroporation process itself. Therefore, tissue property estimations are paramount for treatment planning with electroporation therapies. Ex vivo methods to find electrical tissue properties often misrepresent the targeted tissue, especially when translating results to tumors. A voltage ramp is an in situ method that applies a series of increasing electric potentials across treatment electrodes and measures the resulting current. Here, we develop a robust deep neural network, trained on finite element model simulations, to directly predict tissue properties from a measured voltage ramp. There was minimal test error (R2>0.94;p<0.0001) in three important electric tissue properties. Further, our model was validated to correctly predict the complete dynamic conductivity curve in a previously characterized ex vivo liver model (R2>0.93;p<0.0001) within 100 s from probe insertion, showing great utility for a clinical application. Lastly, we characterize the first reported electrical tissue properties of lung tumors from five canine patients (R2>0.99;p<0.0001). We believe this platform can be incorporated prior to treatment to quickly ascertain patient-specific tissue properties required for electroporation treatment planning models or real-time treatment prediction algorithms. Further, this method can be used over traditional ex vivo methods for in situ tissue characterization with clinically relevant geometries.
Collapse
Affiliation(s)
- Edward J Jacobs
- Department of Biomedical Engineering and Mechanics, Virginia Tech and Wake Forest University, Blacksburg, VA, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech and Emory University, Atlanta, GA, USA.
| | - Kenneth N Aycock
- Department of Biomedical Engineering and Mechanics, Virginia Tech and Wake Forest University, Blacksburg, VA, USA
| | - Pedro P Santos
- Department of Biomedical Engineering and Mechanics, Virginia Tech and Wake Forest University, Blacksburg, VA, USA; Department of Electrical Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Joanne L Tuohy
- Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Rafael V Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech and Wake Forest University, Blacksburg, VA, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech and Emory University, Atlanta, GA, USA
| |
Collapse
|
24
|
Lee XW, Freeman BM, Gunthorpe NG, Eagle LM, Webster MA, Betts JR, Denman RA, Haqqani HM. Pulsed Field Ablation of Atrial Fibrillation: An Initial Australian Single-Centre Experience. Heart Lung Circ 2024; 33:46-54. [PMID: 38065830 DOI: 10.1016/j.hlc.2023.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 10/18/2023] [Accepted: 10/29/2023] [Indexed: 02/13/2024]
Abstract
BACKGROUND Pulsed field ablation (PFA) is a newer ablation energy source with the potential to reduce complications and improve efficacy compared to conventional thermal atrial fibrillation (AF) ablation. This study aimed to present an initial single-centre Australian experience of PFA for AF ablation. METHODS Initial consecutive patients undergoing PFA for paroxysmal or persistent AF at a single centre were included. Baseline patient characteristics, procedural data and clinical outcomes were collected prospectively at the time of the procedure. Patients were followed up at 3 months and 6-monthly thereafter. RESULTS In total, 100 PFA procedures were performed in 97 patients under general anaesthesia. All pulmonary veins (403 of 403) were successfully isolated acutely. Median follow-up was 218 days (range, 16-343 days), and the Kaplan-Meier estimate for freedom from atrial arrhythmias at 180 days was 87% (95% confidence interval 79%-95%). Median procedure time was 74 minutes (range, 48-134 minutes). Median fluoroscopy dose-area product was 345 μGym2 (interquartile range, 169-685 μGym2). Two (2%) pseudoaneurysm vascular access complications occurred. There were no cases of thromboembolic complications, stroke, phrenic nerve palsy, pulmonary vein stenosis, atrio-oesophageal fistula, or pericardial tamponade. CONCLUSIONS Pulsed field ablation can be performed safely and efficiently, with encouraging efficacy in early follow-up. Further data and clinical trials will be required to assess the comparative utility of PFA in contemporary AF ablation practice.
Collapse
Affiliation(s)
- Xiang Wen Lee
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia; Faculty of Medicine, University of Queensland, Brisbane, Qld, Australia
| | - Blake M Freeman
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia
| | - Nicole G Gunthorpe
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia
| | - Liam M Eagle
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia
| | - Meghan A Webster
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia
| | - John R Betts
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia
| | - Russell A Denman
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia
| | - Haris M Haqqani
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Qld, Australia; Faculty of Medicine, University of Queensland, Brisbane, Qld, Australia.
| |
Collapse
|
25
|
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Focal pulsed field ablation and ultrahigh-density mapping - versatile tools for all atrial arrhythmias? Initial procedural experiences. J Interv Card Electrophysiol 2024; 67:99-109. [PMID: 37249807 PMCID: PMC10769919 DOI: 10.1007/s10840-023-01570-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 05/16/2023] [Indexed: 05/31/2023]
Abstract
BACKGROUND Focal pulsed field ablation (FPFA) is a novel and promising method of cardiac ablation. The aim of this study was to report the feasibility, short-term safety, and procedural findings for a broad spectrum of ablated atrial arrhythmias. METHODS Patients (n = 51) scheduled for ablation of atrial arrhythmias were prospectively included and underwent FPFA using the Galvanize CENTAURI generator with energy delivery through commercially available ablation catheters with ultrahigh-density (UHDx) 3D electroanatomic voltage/local activation time map evaluations. Workflow, procedural data, and peri-procedural technical errors and complications are described. RESULTS Planned ablation strategy was achieved with FPFA-only in 48/51 (94%) of the cases. Ablation strategy was first-time pulmonary vein isolation (PVI) in 17/51 (36%), repeat ablation in 18/51 (38%), PVI + in 13/51 (28%), and cavotricuspid isthmus block (CTI)-only in 3/51 (6%). The mean procedure time was 104 ± 31 min (first-time PVI), 114 ± 26 min (repeat procedure), 152 ± 36 min (PVI +), and 62 ± 17 min (CTI). Mean UHDx mapping time to assess lesion formation and block after ablation was 7 ± 4 min with 5485 ± 4809 points. First pass acute (linear) isolation with bidirectional block for anatomical lesion sets was 120/124 (97%) for all PVs, 17/17 (100%) for (any) isthmus, and 14/17 (82%) for left atrium posterior wall (LAPW). We observed several time-consuming integration errors with the used ablation system (mean 3.4 ± 3.7 errors/procedure), one transient inferior ST elevation when ablating CTI resolved by intravenous nitroglycerine and one transient AV block requiring temporary pacing for > 24 h. CONCLUSIONS FPFA was a highly versatile method to treat atrial arrhythmias with high first-pass efficiency. UHDx revealed acute homogenous low-voltage lesions in ablated areas. More data is needed to establish lesion durability and limitations of FPFA.
Collapse
Affiliation(s)
- Martin H Ruwald
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.
| | - Arne Johannessen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Morten Lock Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Martin Haugdal
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Rene Worck
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| | - Jim Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark
| |
Collapse
|
26
|
Peng W, Polajžer T, Yao C, Miklavčič D. Dynamics of Cell Death Due to Electroporation Using Different Pulse Parameters as Revealed by Different Viability Assays. Ann Biomed Eng 2024; 52:22-35. [PMID: 37704904 PMCID: PMC10761553 DOI: 10.1007/s10439-023-03309-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/02/2023] [Indexed: 09/15/2023]
Abstract
The mechanisms of cell death due to electroporation are still not well understood. Recent studies suggest that cell death due to electroporation is not an immediate all-or-nothing response but rather a dynamic process that occurs over a prolonged period of time. To investigate whether the dynamics of cell death depends on the pulse parameters or cell lines, we exposed different cell lines to different pulses [monopolar millisecond, microsecond, nanosecond, and high-frequency bipolar (HFIRE)] and then assessed viability at different times using different viability assays. The dynamics of cell death was observed by changes in metabolic activity and membrane integrity. In addition, regardless of pulse or cell line, the dynamics of cell death was observed only at high electroporation intensities, i.e., high pulse amplitudes and/or pulse number. Considering the dynamics of cell death, the clonogenic assay should remain the preferred viability assay for assessing viability after electroporation.
Collapse
Affiliation(s)
- Wencheng Peng
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, 400044, China
| | - Tamara Polajžer
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, 1000, Ljubljana, Slovenia
| | - Chenguo Yao
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, 400044, China
| | - Damijan Miklavčič
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, 1000, Ljubljana, Slovenia.
| |
Collapse
|
27
|
Farnir F, Luermans J, Manusama R, den Uijl D, Chaldoupi SM, Linz D. Focal point-by-point pulsed field ablation for the treatment of atrial arrhythmias in patients with challenging anatomy where radiofrequency ablation cannot be applied: A case series. HeartRhythm Case Rep 2024; 10:21-25. [PMID: 38264121 PMCID: PMC10801091 DOI: 10.1016/j.hrcr.2023.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2024] Open
Affiliation(s)
- Florent Farnir
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands
| | - Justin Luermans
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands
| | - Randolph Manusama
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands
- Department of Cardiology, Zuyderland Medical Centre, Heerlen, The Netherlands
| | - Dennis den Uijl
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands
| | - Sevasti Maria Chaldoupi
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands
| | - Dominik Linz
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
28
|
Aryana A, Hata C, de la Rama A, Nguyen K, Panescu D. A novel pulsed field ablation system using linear and spiral ablation catheters can create large and durable endocardial and epicardial ventricular lesions in vivo. J Interv Card Electrophysiol 2023:10.1007/s10840-023-01714-6. [PMID: 38157151 DOI: 10.1007/s10840-023-01714-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 11/26/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND We investigated the preclinical safety and efficacy of ventricular pulsed field ablation (PFA) using a family of novel, 6-/8-Fr, linear, and spiral PFA/mapping catheters (CRC EP, Inc). METHODS QRS-gated, bipolar PFA (>2.0 kV) was performed in 10 healthy swine. Altogether, 20 endocardial and epicardial right and left ventricular applications were delivered. The catheters were inserted through an 8.5-Fr steerable introducer. The intensity of skeletal muscle activation was quantified using an accelerometer. Lesions were assessed by pre- versus post-PFA electrogram analysis, pacing threshold, 3D voltage mapping, necropsy, and histology. The swine rete mirabile, liver and kidneys were examined for embolic events. RESULTS All applications were single-shot (56 ± 18 s) without catheter repositioning. Minimal microbubbling was observed without significant skeletal muscle stimulation (mean acceleration 0.05 m/s2) or ventricular tachyarrhythmias. There was significant reduction in post- versus pre-PFA electrogram amplitude (0.5 ± 0.2 mV versus 3.2 ± 0.9 mV, P < 0.001) with a marked increase in pacing threshold (>20 mA versus 7.5 ± 2.9 mA, P < 0.001). All lesions were large and durable up to 28 days, measuring 32 ± 5 mm (length), 27 ± 8 mm (width), and 8 ± 3 mm (depth) using the spiral catheters and 43 ± 1 mm (length), 7 ± 1 mm (width), and 8 ± 1 mm (depth) using the linear catheters. Despite higher waveform voltages and prolonged applications, no thermal effects were detected at necropsy/histology. Moreover, gross and microscopic examinations revealed no evidence of thromboembolism, vascular or collateral injury. CONCLUSIONS A novel, QRS-gated PFA system using linear and spiral PFA catheters is capable of creating large and durable ventricular lesions in vivo without significant microbubbling, ventricular arrhythmias or thromboembolism.
Collapse
Affiliation(s)
- Arash Aryana
- Mercy General Hospital and Dignity Health Heart and Vascular Institute, 3941 J Street, Suite #350, Sacramento, CA, 95819, USA.
| | | | | | | | | |
Collapse
|
29
|
Pu S, Liu F, Chen Y, Luo C, Li P, Chen Y, Fu L, Liu H, Ye X, Wu S, Xue Y, Lin W. 'Single-shot' pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy. Europace 2023; 26:euad362. [PMID: 38109928 PMCID: PMC10757452 DOI: 10.1093/europace/euad362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/25/2023] [Accepted: 12/08/2023] [Indexed: 12/20/2023] Open
Abstract
AIMS Pulsed field ablation (PFA) is emerging as a non-thermal, tissue-specific technique for pulmonary vein isolation (PVI) in atrial fibrillation therapy. This pre-clinical study aims to investigate the feasibility and safety of PVI using a novel PFA system including a nanosecond-scale PFA generator, a novel lotos PFA catheter, and a customized 12 Fr steerable sheath. METHODS AND RESULTS A total of 11 Yorkshire swine were included in this study, with 4 in the acute cohort and 7 in the chronic cohort. Under general anaesthesia, transseptal puncture and pulmonary vein (PV) angiography was initially performed. The PFA catheter was navigated to position at the right and left PV antrum after the electroanatomic reconstruction of the left atrium. Biphasic PFA applications were performed on PVs in both the spindle-shaped and the lotos-shaped poses. Pulmonary vein isolation and PFA-associated safety were assessed 30 min after ablation in both cohorts and 30 days later in the chronic cohort. Detailed necropsy and histopathology were performed. Additional intracardiac echocardiography and coronary angiogram were evaluated for safety. All target PVs (n = 20) were successfully isolated on the first attempt. No spasm of coronary artery or microbubble was seen during the procedure. Eleven of 12 PVs (91.6%) remained in isolation at the 30-day invasive study. No evidence of PV stenosis was observed in any targets. However, transient diaphragm capture occurred in 17.6%. Histopathological examinations showed no evidence of collateral injury. CONCLUSION This study provides scientific evidence demonstrating the safety and efficacy of the novel PFA catheter and system for single-shot PVI, which shows great potential.
Collapse
Affiliation(s)
- Sijia Pu
- School of Medicine, South China University of Technology, Guangzhou, China
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Fangzhou Liu
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Yuhan Chen
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Cihua Luo
- Insight Medtech Co., Ltd, Shenzhen, China
| | - Peng Li
- Insight Medtech Co., Ltd, Shenzhen, China
| | - Yanlin Chen
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Lu Fu
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Huiyi Liu
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Xingdong Ye
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Shulin Wu
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Yumei Xue
- School of Medicine, South China University of Technology, Guangzhou, China
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| | - Weidong Lin
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China
| |
Collapse
|
30
|
Venier S, Vaxelaire N, Jacon P, Carabelli A, Desbiolles A, Garban F, Defaye P. Severe acute kidney injury related to haemolysis after pulsed field ablation for atrial fibrillation. Europace 2023; 26:euad371. [PMID: 38175788 PMCID: PMC10776308 DOI: 10.1093/europace/euad371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 12/05/2023] [Indexed: 01/06/2024] Open
Abstract
AIMS Pulsed field ablation (PFA) has been proposed as a novel alternative to radiofrequency (RF) and cryoablation in the treatment of atrial fibrillation (AF). Following the occurrence of two cases of acute kidney injury (AKI) secondary to haemolysis after a PFA procedure, we evaluated haemolysis in a cohort of consecutive patients. METHODS AND RESULTS Two cases of AKI occurred in last May and June 2023. AKI was secondary to acute and severe haemolysis after a PFA procedure. From June 2023, a total of 68 consecutive patients (64.3 ± 10.5 years) undergoing AF ablation with PFA were enrolled in the study. All patients had a blood sample the day after the procedure for the assessment of haemolysis indicators. The pentaspline PFA catheter was used with a total number of median applications of 64 (54; 76). Nineteen patients (28%) showed significantly depleted haptoglobin levels (<0.04 g/L). A significant inverse correlation was found between the plasma level of haptoglobin and the total number of applications. Two groups were compared: the haemolysis+ group (haptoglobin < 0.04 g/L) vs. the haemolysis- group. The total number of applications was significantly higher in the haemolysis+ group vs the haemolysis - group respectively 75 (62; 127) vs 62 (54; 71) P = 0.011. More than 70 applications seem to have better sensitivity and specificity to predict haemolysis. CONCLUSION Intravascular haemolysis can occur after certain procedures of PFA. Acute kidney injury is a phenomenon that appears to be very rare after a PFA procedure. However, caution must be exercised in the number of applications to avoid severe haemolysis.
Collapse
Affiliation(s)
- Sandrine Venier
- Department of Cardiology, Electrophysiology Unit, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| | - Nathan Vaxelaire
- Department of Cardiology, Electrophysiology Unit, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| | - Peggy Jacon
- Department of Cardiology, Electrophysiology Unit, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| | - Adrien Carabelli
- Department of Cardiology, Electrophysiology Unit, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| | - Antoine Desbiolles
- Department of Cardiology, Electrophysiology Unit, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| | - Frederic Garban
- Department of Hematology, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| | - Pascal Defaye
- Department of Cardiology, Electrophysiology Unit, University Hospital of Grenoble Alpes France, CS10217, 38043 Grenoble Cedex 9, France
| |
Collapse
|
31
|
Della Rocca DG, Marcon L, Magnocavallo M, Menè R, Pannone L, Mohanty S, Sousonis V, Sorgente A, Almorad A, Bisignani A, Głowniak A, Del Monte A, Bala G, Polselli M, Mouram S, La Fazia VF, Ströker E, Gianni C, Zeriouh S, Bianchi S, Sieira J, Combes S, Sarkozy A, Rossi P, Boveda S, Natale A, de Asmundis C, Chierchia GB. Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison. Europace 2023; 26:euae016. [PMID: 38245007 PMCID: PMC10823352 DOI: 10.1093/europace/euae016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 01/14/2024] [Indexed: 01/22/2024] Open
Abstract
AIMS Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.
Collapse
Affiliation(s)
- Domenico G Della Rocca
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
- St. David’s Medical Center, Texas Cardiac Arrhythmia Institute, 3000 N Interstate Hwy 35 Suite 720, Austin, 78705 TX, USA
| | - Lorenzo Marcon
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Michele Magnocavallo
- Arrhythmology Unit, Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Roberto Menè
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | - Luigi Pannone
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Sanghamitra Mohanty
- St. David’s Medical Center, Texas Cardiac Arrhythmia Institute, 3000 N Interstate Hwy 35 Suite 720, Austin, 78705 TX, USA
| | | | - Antonio Sorgente
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Alexandre Almorad
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Antonio Bisignani
- Arrhythmology Unit, Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Andrzej Głowniak
- Department of Cardiology, Medical University of Lublin, Lublin, Poland
| | - Alvise Del Monte
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Marco Polselli
- Arrhythmology Unit, Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Sahar Mouram
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Vincenzo Fazia La Fazia
- St. David’s Medical Center, Texas Cardiac Arrhythmia Institute, 3000 N Interstate Hwy 35 Suite 720, Austin, 78705 TX, USA
| | - Erwin Ströker
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Carola Gianni
- St. David’s Medical Center, Texas Cardiac Arrhythmia Institute, 3000 N Interstate Hwy 35 Suite 720, Austin, 78705 TX, USA
| | - Sarah Zeriouh
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | - Stefano Bianchi
- Arrhythmology Unit, Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Juan Sieira
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | | | - Andrea Sarkozy
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Pietro Rossi
- Arrhythmology Unit, Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Serge Boveda
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | - Andrea Natale
- St. David’s Medical Center, Texas Cardiac Arrhythmia Institute, 3000 N Interstate Hwy 35 Suite 720, Austin, 78705 TX, USA
- Case Western Reserve University School of Medicine, Health Education Campus, 9501 Euclid Ave, Cleveland, 44106 OH, USA
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium
| |
Collapse
|
32
|
Badertscher P, Weidlich S, Knecht S, Stauffer N, Krisai P, Voellmin G, Osswald S, Sticherling C, Kühne M. Efficacy and safety of pulmonary vein isolation with pulsed field ablation vs. novel cryoballoon ablation system for atrial fibrillation. Europace 2023; 25:euad329. [PMID: 38036293 PMCID: PMC10751845 DOI: 10.1093/europace/euad329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 10/30/2023] [Indexed: 12/02/2023] Open
Abstract
AIMS Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.
Collapse
Affiliation(s)
- Patrick Badertscher
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Simon Weidlich
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Sven Knecht
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Niklas Stauffer
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Philipp Krisai
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Gian Voellmin
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Stefan Osswald
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Christian Sticherling
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Michael Kühne
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| |
Collapse
|
33
|
Mills MT, Calvert P, Velavan P, Lip GYH, Gupta D. Concurrent percutaneous left atrial appendage occlusion and catheter ablation for atrial fibrillation: State-of-the-art review. Trends Cardiovasc Med 2023:S1050-1738(23)00100-7. [PMID: 37981202 DOI: 10.1016/j.tcm.2023.11.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/08/2023] [Accepted: 11/14/2023] [Indexed: 11/21/2023]
Abstract
Stroke prevention and symptom control are two integral pillars in atrial fibrillation (AF) management. Percutaneous left atrial appendage occlusion (LAAO) is effective at reducing stroke risk in high-risk patients with AF who cannot tolerate oral anticoagulant therapy, whilst catheter ablation is effective at reducing AF burden and improving quality-of-life in patients who remain symptomatic despite medical therapy. If both procedures are indicated in an individual patient, they have traditionally been performed on separate occasions, due to long cumulative procedural times, itself associated with thromboembolic risk. Recently, with the advancement of procedural techniques, the concept of concurrent LAAO and AF catheter ablation has gained traction. This review summarises the evidence for and against concurrent LAAO and AF catheter ablation, discussing procedural considerations, including procedural sequencing and post-procedural antithrombotic therapy, safety and efficacy outcomes, and future directions in the field.
Collapse
Affiliation(s)
- Mark T Mills
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK; Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool L14 3PE, UK
| | - Peter Calvert
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK; Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool L14 3PE, UK
| | - Periaswamy Velavan
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK
| | - Gregory Y H Lip
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK; Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool L14 3PE, UK; Danish Center for Health Services Research, Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Dhiraj Gupta
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK; Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool L14 3PE, UK.
| |
Collapse
|
34
|
Yang M, Wang PY, Hao YL, Liang M, Yu ZY, Li XC, Li YP. A real-world case-control study on the efficacy and safety of pulsed field ablation for atrial fibrillation. Eur J Med Res 2023; 28:519. [PMID: 37968748 PMCID: PMC10648358 DOI: 10.1186/s40001-023-01509-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 11/05/2023] [Indexed: 11/17/2023] Open
Abstract
OBJECTIVE The primary objective of this study was to evaluate the efficacy and safety of pulsed field ablation in individuals diagnosed with atrial fibrillation. METHODS A total of 36 patients diagnosed with atrial fibrillation were enrolled in the pulsed field ablation group, while another 36 patients diagnosed with atrial fibrillation were included in the radiofrequency ablation group. Among the study participants, 15 patients in the pulsed field ablation group and 17 patients in the radiofrequency ablation group had persistent atrial fibrillation. Comprehensive comparisons were made between the two groups, including baseline data, underlying diseases, medication usage, intraoperative parameters, and atrial fibrillation recurrence rates at 1, 3, and 6 months during the postoperative follow-up period. RESULTS (1) There were no significant differences observed between the two groups concerning baseline data and antiarrhythmic drug usage (P > 0.05); (2) the effective ablation time for both left and right pulmonary veins in the pulsed field ablation group was markedly shorter compared to the radiofrequency ablation group (P < 0.001 for each vein); (3) within the pulsed field ablation group, the number of discharges, catheter operation time, and effective ablation time for the left pulmonary vein were significantly higher than those for the right pulmonary vein (P < 0.05). Conversely, in the radiofrequency ablation group, the number of discharges for the left pulmonary vein was significantly higher than that for the right pulmonary vein (P < 0.05); and (4) when comparing sinus rhythm maintenance at 1, 3, and 6 months postoperatively, no statistically significant differences were noted between the two groups for paroxysmal, persistent, and paroxysmal + persistent atrial fibrillation cases (P > 0.05). CONCLUSION During the 6-month follow-up period, pulsed field ablation demonstrated comparable efficacy to radiofrequency ablation with respect to recurrence rates for both paroxysmal and persistent atrial fibrillation. Moreover, pulsed field ablation exhibited high safety levels, excellent surgical efficiency, and a notably brief learning curve, affirming its viability as a therapeutic option for these conditions.
Collapse
Affiliation(s)
- Ming Yang
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China.
| | - Peng-Yu Wang
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China
| | - Ying-Lu Hao
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China
| | - Mei Liang
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China
| | - Zi-Yang Yu
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China
| | - Xi-Chen Li
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China
| | - Yan-Ping Li
- Department of Cardiology, The People's Hospital of Yuxi City, The 6th Affiliated Hospital of Kunming Medical University, No.21 of Nieer Road, Hongta District, Yuxi, 653100, China
| |
Collapse
|
35
|
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Pulsed field ablation in real-world atrial fibrillation patients: clinical recurrence, operator learning curve and re-do procedural findings. J Interv Card Electrophysiol 2023; 66:1837-1848. [PMID: 36753029 DOI: 10.1007/s10840-023-01495-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 01/25/2023] [Indexed: 02/09/2023]
Abstract
BACKGROUND Pulsed field ablation (PFA) is a novel method of cardiac ablation demonstrated in early pre-clinical and clinical settings. The aim of this study was to report the safety and clinical efficacy of pulmonary vein isolation (PVI) with PFA for real-world atrial fibrillation (AF) patients. METHODS All-comer AF patients (n = 121, 59% paroxysmal) were prospectively included and underwent PFA with 100% high-density voltage maps performed after PVI. Clinical outcomes were gathered by chart review. RESULTS PVI was achieved with PFA-only in 119 (98%) of the cases. During the implementation phase the mean procedure and fluoroscopy time was reduced from 85 ± 34 to 72 ± 18 min (p = 0.044) and 22 ± 9 to 16 ± 4 (p = 0.034). We observed one phrenic nerve palsy with only partial remission at follow-up. Other adverse events were numerically comparable to standard PVI procedures. Over a mean follow-up of 308 ± 87 days, a total of 22/121 (18.2%) cases experienced clinically significant recurrence or initiation of anti-arrhythmic drugs with Kaplan-Meier event-free estimate at 365 days of 80% (88% for paroxysmal versus 69% for persistent). In five of eight re-do procedures, gaps were primarily located at the right pulmonary veins. CONCLUSIONS PFA was a highly efficient method to achieve PVI with reductions in procedure time and fluoroscopy over the implementation period. The procedural data and clinical recurrence rates from initial trials were confirmed in real-life non-selected AF patients. More data is needed to establish lesion durability and limitations of PFA.
Collapse
Affiliation(s)
- Martin H Ruwald
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Hellerup, Denmark.
| | - Arne Johannessen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Hellerup, Denmark
| | - Morten Lock Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Hellerup, Denmark
| | - Martin Haugdal
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Hellerup, Denmark
| | - Rene Worck
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Hellerup, Denmark
| | - Jim Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Hellerup, Denmark
| |
Collapse
|
36
|
Schipper JH, Steven D, Lüker J, Wörmann J, van den Bruck JH, Filipovic K, Dittrich S, Scheurlen C, Erlhöfer S, Pavel F, Sultan A. Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation. J Cardiovasc Electrophysiol 2023; 34:2019-2026. [PMID: 37682001 DOI: 10.1111/jce.16056] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 08/18/2023] [Accepted: 08/28/2023] [Indexed: 09/09/2023]
Abstract
INTRODUCTION Pulmonary vein isolation (PVI) remains the cornerstone in the treatment of atrial fibrillation (AF). PVI using cryoballoon (CB) technology has emerged as a standard procedure in many centers. Recently, pulsed field ablation (PFA) has been introduced and used to achieve PVI. First data show high acute and favorable long-term outcomes. So far, data comparing these new "single shot" devices are sparse. We sought to compare procedural and outcome data for first time PFA users versus CB in patients undergoing de novo PVI. Furthermore, potentially postprocedural discomfort and affection of autonomic ganglia were assessed. METHODS AND RESULTS A retrospective analysis and comparison of all de novo PVIs with PFA and CB was performed. Furthermore, PFA PVI learning curve was evaluated. During follow-up, repeat outpatient visits and Holter electrocardiogram were performed to analyze arrhythmia-free survival. Discomfort analysis was obtained by prescribed analgesic medication within first 48 h after PVI. Potential changes in heart rate (HR) between baseline and at 3-month follow-up were evaluated. A total of 108 patients (54 PFA and 54 CB; PFA; 33 (30%) female) with paroxysmal and persistent AF were analyzed. Type of AF was comparable (Patients suffering from PAF: PFA: 16 (30%), CB: 17 (31%), p = 1.0). In 107 (99%) patients, successful PVI was achieved. Transient phrenic palsy omitted complete PVI in one CB patient. A trend for a shorter overall procedure duration was observed in the PFA group (PFA: 64.5 ± 17.5 min; CB: 73.0 ± 24.8 min; p = 0.07). Excluding LA mapping time (first 14 cases), procedure time was significantly shorter using PFA (PFA: 58.0 ± 12.5 min, CB: 73.0 ± 24.8 min, p = 0.0001). Fluoroscopy time was significantly longer for PFA (PFA: 15.3 ± 4.7 min, CB: 12.3 ± 5.3 min; p = 0.001), but significantly less contrast medium was used (PFA: 12 ± 6 mL; CB: 51 ± 29 mL, p < 0.0001). Subgroup analysis of the PFA group revealed a significant shortening of procedure duration over time (first tertile: 72.7 ± 13.5 min, second tertile: 67.3 ± 21.7 min, third tertile: 53.4 ± 9.8 min, first vs. third tertile p < 0.0001). Two cardiac tamponades occurred in the PFA group (p = 0.495), of which one was most likely related to complex transseptal puncture. In the first 48 h after PVI, the number of prescribed analgesics due to postprocedural pain was equal between both groups (PFA: 7 (13%) patients, CB: 10 (19%) patients, p = 0.598). After a FU of 273 ± 129 days, 35 of 47 patients (74%) after PFA and 36 of 50 patients (72%) after CB PVI were free of any atrial arrhythmia (HR: 0.98, p = 0.88). Only in the PFA group, a significant increase in HR 3 months after PVI was observed (pre-PVI: 61 ± 8 beats/min, post-PVI: 65 ± 9 beats/min, p = 0.008). CONCLUSION The new PFA technology is equally effective and safe as compared to CB for complete PVI with potentially shorter procedure time and significantly less contrast medium. However, AF recurrence rates after PFA PVI seem to be comparable to CB PVI.
Collapse
Affiliation(s)
- Jan-Hendrik Schipper
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Daniel Steven
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Jakob Lüker
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Jonas Wörmann
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | | | - Karlo Filipovic
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Sebastian Dittrich
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Cornelia Scheurlen
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Susanne Erlhöfer
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Friederike Pavel
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| | - Arian Sultan
- Department of Electrophysiology, Heart Center, University of Cologne, Köln, Germany
| |
Collapse
|
37
|
Aldaas OM, Malladi C, Aldaas AM, Han FT, Hoffmayer KS, Krummen D, Ho G, Raissi F, Birgersdotter-Green U, Feld GK, Hsu JC. Safety and acute efficacy of catheter ablation for atrial fibrillation with pulsed field ablation vs thermal energy ablation: A meta-analysis of single proportions. Heart Rhythm O2 2023; 4:599-608. [PMID: 37936671 PMCID: PMC10626185 DOI: 10.1016/j.hroo.2023.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023] Open
Abstract
Background Pulsed field ablation (PFA) has emerged as a novel energy source for the ablation of atrial fibrillation (AF) using ultrarapid electrical pulses to induce cell death via electroporation. Objective The purpose of this study was to compare the safety and acute efficacy of ablation for AF with PFA vs thermal energy sources. Methods We performed an extensive literature search and systematic review of studies that evaluated the safety and efficacy of ablation for AF with PFA and compared them to landmark clinical trials for ablation of AF with thermal energy sources. Freeman-Tukey double arcsine transformation was used to establish variance of raw proportions followed by the inverse with the random-effects model to combine the transformed proportions and generate the pooled prevalence and 95% confidence interval (CI). Results We included 24 studies for a total of 5203 patients who underwent AF ablation. Among these patients, 54.6% (n = 2842) underwent PFA and 45.4% (n = 2361) underwent thermal ablation. There were significantly fewer periprocedural complications in the PFA group (2.05%; 95% CI 0.94-3.46) compared to the thermal ablation group (7.75%; 95% CI 5.40-10.47) (P = .001). When comparing AF recurrence up to 1 year, there was a statistically insignificant trend toward a lower prevalence of recurrence in the PFA group (14.24%; 95% CI 6.97-23.35) compared to the thermal ablation group (25.98%; 95% CI 15.75-37.68) (P = .132). Conclusion Based on the results of this meta-analysis, PFA was associated with lower rates of periprocedural complications and similar rates of acute procedural success and recurrent AF with up to 1 year of follow-up compared to ablation with thermal energy sources.
Collapse
Affiliation(s)
- Omar M. Aldaas
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Chaitanya Malladi
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Amer M. Aldaas
- T. Still University School of Osteopathic Medicine, Mesa, Arizona
| | - Frederick T. Han
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Kurt S. Hoffmayer
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - David Krummen
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Gordon Ho
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Farshad Raissi
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Ulrika Birgersdotter-Green
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Gregory K. Feld
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| | - Jonathan C. Hsu
- Section of Cardiac Electrophysiology, Division of Cardiology at the University of California San Diego Health System, La Jolla, California
| |
Collapse
|
38
|
Magni FT, Scherr D, Manninger M, Sohns C, Sommer P, Hovakimyan T, Blaauw Y, Mulder BA. Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation. J Interv Card Electrophysiol 2023; 66:1729-1737. [PMID: 37195355 PMCID: PMC10547612 DOI: 10.1007/s10840-023-01559-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 05/01/2023] [Indexed: 05/18/2023]
Abstract
BACKGROUND Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. METHODS We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flutter or tachycardia (AFL/AT) following PVI with PFA. We report electrophysiological findings and ablation strategy during redo-ablation. RESULTS Of 447 patients undergoing index PVI with PFA, 14 patients (age: 61.9±10.8 years; 7 (50.0%) males; left atrial volume index (n=10): 39.4±14.6 mL/m2) were referred for redo-ablation. Initial indication was paroxysmal-AF in 7 patients, persistent-AF in 6 and long-standing-persistent-AF in one patient. Mean time-to-recurrence was 4.9±1.9 months. Three patients received additional posterior-wall-isolation during index PFA. Twelve (85.7%) patients suffered AF recurrence and 5/12 had concomitant AFL. In the remaining 2 patients, one had a (box-dependent) AFL, and one had an atypical AT. No patients had all PVs reconnected. Reconnection in zero, one, two or three PVs was found in 35.7%, 21.4%, 14.3%, and 28.6% of patients, respectively. All 7 patients with zero or one reconnection with AF recurrence received additional/repeat posterior-wall-isolation during re-ablation, while in the others, PVs were re-isolated. Patients with only AFL/AT had no reconnection of PVs, and the substrate was successfully ablated. CONCLUSIONS Durable PVI (all PV's isolated) was observed in over one-third of patients at re-do. The predominant recurrent arrhythmia following PVI-only was AF. Concomitant (35.7%) or isolated (14.3%) AFL/AT recurrence was observed in 50% of patients.
Collapse
Affiliation(s)
- Federico Tancredi Magni
- Department of Cardiology, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700, RB, Groningen, The Netherlands.
| | - Daniel Scherr
- Department of Medicine, Division of Cardiology, Medical University of Graz, Graz, Austria
| | - Martin Manninger
- Department of Medicine, Division of Cardiology, Medical University of Graz, Graz, Austria
| | - Christian Sohns
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Bad Oeynhausen, Germany
| | - Philip Sommer
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Bad Oeynhausen, Germany
| | - Tatevik Hovakimyan
- Department of Cardiac Arrhythmology, Nork-Marash Medical Center, Armenak Armenakyan 108/4, Yerevan, Armenia
| | - Yuri Blaauw
- Department of Cardiology, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700, RB, Groningen, The Netherlands
| | - Bart A Mulder
- Department of Cardiology, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700, RB, Groningen, The Netherlands
| |
Collapse
|
39
|
Cespón-Fernández M, Della Rocca DG, Almorad A, Magnocavallo M, Pannone L, Koopman P, Sieira J, Bala G, Vetta G, Marcon L, Stroker E, Del Monte A, Juliá-Calvo J, Strisciuglio T, Vijgen J, Bianchi S, Polselli M, Sorgente A, Jesel-Morel L, Stabile G, Poggi S, Íñiguez-Romo A, Rossi P, Sarkozy A, de Asmundis C, Chierchia GB. Versatility of the novel single-shot devices: A multicenter analysis. Heart Rhythm 2023; 20:1463-1465. [PMID: 37479074 DOI: 10.1016/j.hrthm.2023.07.058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 07/13/2023] [Accepted: 07/14/2023] [Indexed: 07/23/2023]
Affiliation(s)
- María Cespón-Fernández
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium; Cardiology Unit, University Hospital Álvaro Cunqueiro, Vigo, Spain
| | - Domenico Giovanni Della Rocca
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium; Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas.
| | - Alexandre Almorad
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Michele Magnocavallo
- Arrhythmology Unit, Hospital of Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Luigi Pannone
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | | | - Juan Sieira
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Giampaolo Vetta
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Lorenzo Marcon
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Erwin Stroker
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Alvise Del Monte
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Justo Juliá-Calvo
- University Hospitals Sussex NHS Foundation Trust, Sussex, United Kingdom
| | | | | | - Stefano Bianchi
- Arrhythmology Unit, Hospital of Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Marco Polselli
- Arrhythmology Unit, Hospital of Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Antonio Sorgente
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | | | | | | | | | - Pietro Rossi
- Arrhythmology Unit, Hospital of Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy
| | - Andrea Sarkozy
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Gian Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| |
Collapse
|
40
|
Hsu JC, Banker RS, Gibson DN, Gomez T, Berman D, Datta K, Chen Q, Doshi SK. Comprehensive dose-response study of pulsed field ablation using a circular catheter compared with radiofrequency ablation for pulmonary vein isolation: A preclinical study. Heart Rhythm O2 2023; 4:662-667. [PMID: 37936668 PMCID: PMC10626186 DOI: 10.1016/j.hroo.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2023] Open
Affiliation(s)
- Jonathan C. Hsu
- Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine University of California San Diego, La Jolla, California
| | | | - Douglas N. Gibson
- Interventional Electrophysiology, Scripps Clinic and Prebys Cardiovascular Institute, La Jolla, California
| | | | | | | | - Qi Chen
- Biosense Webster, Irvine, California
| | | |
Collapse
|
41
|
Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, Calkins H, Sanders P, Packer DL, Kuck KH, Hindricks G, Tada H, Hoyt RH, Irwin JM, Andrade J, Cerkvenik J, Selma J, DeLurgio DB. Influence of monitoring and atrial arrhythmia burden on quality of life and health care utilization in patients undergoing pulsed field ablation: A secondary analysis of the PULSED AF trial. Heart Rhythm 2023; 20:1238-1245. [PMID: 37211146 DOI: 10.1016/j.hrthm.2023.05.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 05/05/2023] [Accepted: 05/12/2023] [Indexed: 05/23/2023]
Abstract
BACKGROUND Freedom from atrial arrhythmia (AA) recurrence ≥30 seconds after pulsed field ablation (PFA) in patients with atrial fibrillation (AF) was reported in PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; ClinialTrials.gov Identifier: NCT04198701). AA burden may be a more clinically meaningful endpoint. OBJECTIVE The purpose of this study was to determine the influence of monitoring strategies on AA detection and AA burden association with quality of life (QoL) and health care utilization (HCU) after PFA. METHODS Patients underwent 24-hour Holter monitoring at 6 and 12 months and weekly, and symptomatic transtelephonic monitoring (TTM). AA burden post-blanking was calculated as the greater of (1) percentage of AA on total Holter time; or (2) percentage of weeks with ≥1 TTM with AA out of all weeks with ≥1 TTM. RESULTS Freedom from all AAs varied by >20% when differing monitoring strategies were used. PFA resulted in zero burden in 69.4% of paroxysmal atrial fibrillation (PAF) and 62.2% of persistent atrial fibrillation (PsAF) patients. Median burden was low (<9%). Most PAF and PsAF patients had ≤1 week of AA detection on TTM (82.6% and 75.4%) and <30 minutes of AA per day of Holter monitoring (96.5% and 89.6%), respectively. Only PAF patients with <10% AA burden averaged a clinically meaningful (>19 point) QoL improvement. PsAF patients experienced clinically meaningful QoL improvements irrespective of burden. Repeat ablations and cardioversions significantly increased with higher AA burden (P <.01). CONCLUSION The ≥30-second AA endpoint is dependent on the monitoring protocol used. PFA resulted in low AA burden for most patients, which was associated with clinically relevant improvement in QoL and reduced AA-related HCU.
Collapse
Affiliation(s)
- Atul Verma
- McGill University Health Centre, Montreal, Quebec, Canada.
| | | | - Lucas V Boersma
- St. Antonius Hospital, Nieuwegein and Amsterdam UMC, The Netherlands
| | - Nitesh Sood
- Southcoast Health Center, Fall River, Massachusetts
| | | | | | | | | | | | | | | | | | | | | | - Jason Andrade
- Vancouver General Hospital, Vancouver, British Columbia, Canada
| | | | | | - David B DeLurgio
- Emory Heart & Vascular Center at Saint Joseph's, Atlanta, Georgia
| |
Collapse
|
42
|
Kueffer T, Seiler J, Madaffari A, Mühl A, Asatryan B, Stettler R, Haeberlin A, Noti F, Servatius H, Tanner H, Baldinger SH, Reichlin T, Roten L. Pulsed-field ablation for the treatment of left atrial reentry tachycardia. J Interv Card Electrophysiol 2023; 66:1431-1440. [PMID: 36496543 PMCID: PMC10457215 DOI: 10.1007/s10840-022-01436-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 11/22/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND We describe our initial experience using a multipolar pulsed-field ablation catheter for the treatment of left atrial (LA) reentry tachycardia. METHODS We included all patients with LA reentry tachycardia treated with PFA at our institution between September 2021 and March 2022. The tachycardia mechanism was identified using 3D electro-anatomical mapping (3D-EAM). Subsequently, a roof line, anterior line, or mitral isthmus line was ablated as appropriate. Roof line ablation was always combined with LA posterior wall (LAPW) ablation. Positioning of the PFA catheter was guided by a 3D-EAM system and by fluoroscopy. Bidirectional block across lines was verified using standard criteria. Additional radiofrequency ablation (RFA) was used to achieve bidirectional block as necessary. RESULTS Among 22 patients (median age 70 (59-75) years; 9 females), we identified 27 LA reentry tachycardia: seven roof dependent macro-reentries, one posterior-wall micro-reentry, twelve peri-mitral macro-reentries, and seven anterior-wall micro-reentries. We ablated a total of 20 roof lines, 13 anterior lines, and 6 mitral isthmus lines. Additional RFA was necessary for two anterior lines (15%) and three mitral isthmus lines (50%). Bidirectional block was achieved across all roof lines, 92% of anterior lines, and 83% of mitral isthmus lines. We observed no acute procedural complications. CONCLUSION Ablation of a roof line and of the LAPW is feasible, effective, and safe using this multipolar PFA catheter. However, the catheter is less suited for ablation of the mitral isthmus and the anterior line. A focal pulsed-field ablation catheter may be more effective for ablation of these lines. This study shows the feasibility to ablate linear lesions with a multipolar pulsed-field ablation catheter. 27 left atrial reentry tachycardia were treated in 22 patients.
Collapse
Affiliation(s)
- Thomas Kueffer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Jens Seiler
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Antonio Madaffari
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Aline Mühl
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Babken Asatryan
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Robin Stettler
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Andreas Haeberlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
- ARTORG Center, University of Bern, Bern, Switzerland
| | - Fabian Noti
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Helge Servatius
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Hildegard Tanner
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Samuel H Baldinger
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Tobias Reichlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland
| | - Laurent Roten
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, CH-3010, Bern, Switzerland.
| |
Collapse
|
43
|
Musikantow DR, Reddy VY, Skalsky I, Shaburishvili T, van Zyl M, O'Brien B, Coffey K, Reilly J, Neuzil P, Asirvatham S, de Groot JR. Targeted ablation of epicardial ganglionated plexi during cardiac surgery with pulsed field electroporation (NEURAL AF). J Interv Card Electrophysiol 2023:10.1007/s10840-023-01615-8. [PMID: 37561246 DOI: 10.1007/s10840-023-01615-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 07/30/2023] [Indexed: 08/11/2023]
Abstract
BACKGROUND Modulation of the cardiac autonomic nervous system (ANS) is a promising adjuvant therapy in the treatment of atrial fibrillation (AF). In pre-clinical models, pulsed field (PF) energy has the advantage of selectively ablating the epicardial ganglionated plexi (GP) that govern the ANS. This study aims to demonstrate the feasibility and safety of epicardial ablation of the GPs with PF during cardiac surgery with a primary efficacy outcome of prolongation of the atrial effective refractory period (AERP). METHODS In a single-arm, prospective analysis, patients with or without a history of AF underwent epicardial GP ablation with PF during coronary artery bypass grafting (CABG). AERP was determined immediately pre- and post- GP ablation to assess cardiac ANS function. Holter monitors were performed to determine rhythm status and heart rate variability (HRV) at baseline and at 1-month post-procedure. RESULTS Of 24 patients, 23 (96%) received the full ablation protocol. No device-related adverse effects were noted. GP ablation resulted in a 20.7 ± 19.9% extension in AERP (P < 0.001). Post-operative AF was observed in 7 (29%) patients. Holter monitoring demonstrated an increase in mean heart rate (74.0 ± 8.7 vs. 80.6 ± 12.3, P = 0.01). There were no significant changes in HRV. There were no study-related complications. CONCLUSIONS This study demonstrates the safety and feasibility of epicardial ablation of the GP using PF to modulate the ANS during cardiac surgery. Large, randomized analyses are necessary to determine whether epicardial PF ablation can offer a meaningful impact on the cardiac ANS and reduce AF. TRIAL REGISTRATION Clinical trial registration: NCT04775264.
Collapse
Affiliation(s)
- Daniel R Musikantow
- Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, Box 1030, One Gustave L. Levy Place, New York, NY, 10029, USA
| | - Vivek Y Reddy
- Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, Box 1030, One Gustave L. Levy Place, New York, NY, 10029, USA.
- Homolka Hospital, Prague, Czech Republic.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Grimaldi M, Quadrini F, Caporusso N, Troisi F, Vitulano N, Delmonte V, Di Monaco A. Deep sedation protocol during atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter. Europace 2023; 25:euad222. [PMID: 37470452 PMCID: PMC10434733 DOI: 10.1093/europace/euad222] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 07/21/2023] Open
Abstract
BACKGROUND Pulsed field ablation (PFA) is a novel, largely nonthermal ablative modality that, by virtue of its putative preferential action on myocardial tissue through the process of irreversible electroporation (IRE), may replace conventional thermal ablation for atrial fibrillation (AF). The recent inspIRE study confirmed safety and effectiveness of a fully integrated biphasic PFA system with a variable loop circular catheter for the treatment of paroxysmal AF. The majority of PFA procedures were performed using general anesthesia. However, due to the risks of general anesthesia we report the data regarding our sedation protocol used during inspIRE study. METHODS A total of 29 patients (mean age 55±9 years; 72% male) were enrolled as part of this analysis within the inspIRE trial. The sedation protocol is reported in the manuscript. The Richmond Agitation-Sedation Scale (RASS), the Visual Analogue Scale (VAS) and the Patient State Index were collected during sedation. Each patient was monitored using the Masimo Sedline. At the end of ablation, the Likert Scale Questionnaire (LSQ) was used to assess the patients' satisfaction with intraoperative analgesia-sedation. RESULTS No procedural complications were documented. Sufficient oxygen saturation was maintained in all patients during procedure. Non-invasive ventilation or tracheal intubation were not required for any patient. The RAAS score between -1 to -5 was obtained in 27 patients (93%) while the value 0 was obtained in 2 patients (7%). The VAS score between 0 to 2 was obtained in 24 patients (83%); the VAS score 3 in 3 patients (10%) and the VAS score 4 in 2 patients (7%). The PSI score <50 was achieved in 16 patients (55%) while the PSI between 50 and 70 was achieved in 9 patients (31%). Positive answers to LSQ were obtained in most patients. CONCLUSION During PFA ablation procedures with the variable-loop circular catheter and its accompanying biphasic pulse, our deep sedation protocol is a valid alternative to general anesthesia.
Collapse
Affiliation(s)
- Massimo Grimaldi
- Dipartimento di Cardiologia, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| | - Federico Quadrini
- Dipartimento di Cardiologia, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| | - Nicola Caporusso
- Reparto di Anestesia e Rianimazione, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| | - Federica Troisi
- Dipartimento di Cardiologia, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| | - Nicola Vitulano
- Dipartimento di Cardiologia, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| | - Vito Delmonte
- Reparto di Anestesia e Rianimazione, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| | - Antonio Di Monaco
- Dipartimento di Cardiologia, Ospedale Generale Regionale ‘F. Miulli’, Acquaviva delle Fonti, Bari, Italy
| |
Collapse
|
45
|
Boersma L, Andrade JG, Betts T, Duytschaever M, Pürerfellner H, Santoro F, Tzeis S, Verma A. Progress in atrial fibrillation ablation during 25 years of Europace journal. Europace 2023; 25:euad244. [PMID: 37622592 PMCID: PMC10451004 DOI: 10.1093/europace/euad244] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 08/08/2023] [Indexed: 08/26/2023] Open
Abstract
The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power. Also, so-called single-shot devices were developed with balloons and arrays to create larger contiguous lesions, and energy sources changed from RF current to cryogenic ablation and more recently pulsed field ablation with electrical current. Although PV ablation has remained the basis for every AF ablation, it was soon recognized that this was not enough to cure all patients, especially those with non-paroxysmal AF. Standardized approaches for additional ablation targets have been used but have not been satisfactory in all patients so far. This led to highly technical mapping systems that are meant to unravel the drivers for the maintenance of AF. In the following sections, the development of energies, strategies, and tools is described with a focus on the contribution of Europace to publish the outcomes of studies that were done during the past 25 years.
Collapse
Affiliation(s)
- Lucas Boersma
- Cardiology Department, St. Antonius Hospital Nieuwegein/Amsterdam University Medical Center, PO 2500, 3430 EM Nieuwegein, The Netherlands
| | - Jason G Andrade
- Department of Medicine, University of British Columbia, Vancouver, Canada
- Cardiology Department, Center for Cardiovascular Innovation, Vancouver, Canada
- Montreal Heart Institute, Department of Medicine, Université de Montréal, Montreal, Canada
| | - Tim Betts
- Department of Cardiology, Oxford University, Oxford, UK
| | | | | | - Francesco Santoro
- Department of Medical and Surgery Sciences, University of Foggia, Foggia, Italy
| | - Stylianos Tzeis
- Cardiology Department, Mitera Hospital, Hygeia Group, Athens, Greece
| | - Atul Verma
- Cardiology Department, McGill University Health Center, Montreal, Quebec, Canada
| |
Collapse
|
46
|
Hansen J, Haugdal MA, Johannessen A, Hansen ML, Worck R, Ruwald MH. Focal pulsed field electroporation of left ventricular premature contractions after failed radiofrequency ablation. HeartRhythm Case Rep 2023; 9:581-585. [PMID: 37614400 PMCID: PMC10444564 DOI: 10.1016/j.hrcr.2023.05.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023] Open
Affiliation(s)
- Jim Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - Martin A. Haugdal
- Division of Electrophysiology, Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - Arne Johannessen
- Division of Electrophysiology, Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - Morten Lock Hansen
- Division of Electrophysiology, Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - Rene Worck
- Division of Electrophysiology, Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - Martin H. Ruwald
- Division of Electrophysiology, Department of Cardiology, Herlev and Gentofte Hospital, Hellerup, Denmark
| |
Collapse
|
47
|
Schmidt B, Bordignon S, Neven K, Reichlin T, Blaauw Y, Hansen J, Adelino R, Ouss A, Füting A, Roten L, Mulder BA, Ruwald MH, Mené R, van der Voort P, Reinsch N, Kueffer T, Boveda S, Albrecht EM, Schneider CW, Chun KRJ. EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry. Europace 2023; 25:euad185. [PMID: 37379528 PMCID: PMC10320231 DOI: 10.1093/europace/euad185] [Citation(s) in RCA: 35] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 05/23/2023] [Indexed: 06/30/2023] Open
Abstract
AIMS Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.
Collapse
Affiliation(s)
- Boris Schmidt
- Cardioangiologisches Centrum Bethanien, Wilhelm-Epstein Str. 4, 60431 Frankfurt, Germany
- Universitätsklinikum Frankfurt, Medizinische Klinik 3- Klinik für Kardiologie, Theodor-Stern-Kai 7, Frankfurt, Germany
| | - Stefano Bordignon
- Cardioangiologisches Centrum Bethanien, Wilhelm-Epstein Str. 4, 60431 Frankfurt, Germany
| | - Kars Neven
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany
| | - Tobias Reichlin
- Inselspital—Bern University Hospital, University of Bern, Bern, Switzerland
| | - Yuri Blaauw
- Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Jim Hansen
- Arrhythmia Unit, Department of Cardiology, Gentofte Hospital, Copenhagen, Denmark
| | - Raquel Adelino
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | - Alexandre Ouss
- Heart Center Catharina Hospital, Eindhoven, The Netherlands
| | - Anna Füting
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany
| | - Laurent Roten
- Inselspital—Bern University Hospital, University of Bern, Bern, Switzerland
| | - Bart A Mulder
- Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Martin H Ruwald
- Arrhythmia Unit, Department of Cardiology, Gentofte Hospital, Copenhagen, Denmark
| | - Roberto Mené
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | | | - Nico Reinsch
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany
| | - Thomas Kueffer
- Inselspital—Bern University Hospital, University of Bern, Bern, Switzerland
| | - Serge Boveda
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | | | | | | |
Collapse
|
48
|
Anić A, Phlips T, Brešković T, Koopman P, Girouard S, Mediratta V, Jurišić Z, Sikirić I, Lisica L, Vijgen J. Pulsed field ablation using focal contact force-sensing catheters for treatment of atrial fibrillation: acute and 90-day invasive remapping results. Europace 2023; 25:euad147. [PMID: 37335976 PMCID: PMC10279421 DOI: 10.1093/europace/euad147] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 05/17/2023] [Indexed: 06/21/2023] Open
Abstract
AIMS Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. METHODS AND RESULTS ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3-5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. CONCLUSION ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.
Collapse
Affiliation(s)
- Ante Anić
- Heart and vascular center, Klinički Bolnički Centar (KBC) Split, Spinčićeva ul. 1, Split 21000, Croatia
| | | | - Toni Brešković
- Heart and vascular center, Klinički Bolnički Centar (KBC) Split, Spinčićeva ul. 1, Split 21000, Croatia
| | | | - Steven Girouard
- Galvanize Therapeutics, Inc. (previously Galaxy Medical), Redwood City, CA, USA
| | | | - Zrinka Jurišić
- Heart and vascular center, Klinički Bolnički Centar (KBC) Split, Spinčićeva ul. 1, Split 21000, Croatia
| | - Ivan Sikirić
- Heart and vascular center, Klinički Bolnički Centar (KBC) Split, Spinčićeva ul. 1, Split 21000, Croatia
| | - Lucija Lisica
- Heart and vascular center, Klinički Bolnički Centar (KBC) Split, Spinčićeva ul. 1, Split 21000, Croatia
| | | |
Collapse
|
49
|
Alkukhun L, Sandhu U, Hodovan J, Zhao Y, Chiang K, Castellvi Q, Stenzel P, Woltjer R, Li X, Barajas RF, Nazer B. Multi-modality imaging assessment of microbubbles and cerebral emboli in left ventricular pulsed field ablation. J Interv Card Electrophysiol 2023:10.1007/s10840-023-01529-5. [PMID: 37188871 DOI: 10.1007/s10840-023-01529-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 03/15/2023] [Indexed: 05/17/2023]
Abstract
BACKGROUND Pulsed field ablation (PFA) may have a superior safety profile compared to other technologies, but it has the potential to cause gaseous microbubbles (MB), which may be associated with cerebral emboli. Limited relative safety data has been published regarding PFA in the left ventricle (LV). METHODS Healthy and chronic myocardial infarction (MI) swine underwent PFA (monopolar, biphasic, 25 Amps) in the LV using an irrigated focal catheter under intra-cardiac echocardiography (ICE) guidance for MB monitoring. Two control swine received air MBs through the lumen of the ablation catheter. Swine underwent brain MRI before and after PFA (or control air MB injection). Gross pathology and histology of brains with abnormal MRI findings were performed. RESULTS Four healthy and 5 chronic MI swine underwent 124 left ventricular PFA applications. No PFA-related MB formation was noted on ICE. Both control swine developed multiple acute emboli in the thalamus and caudate on DWI, ADC, and FLAIR brain MRI images in response to air MB injection. Of the 9 PFA swine, there were no abnormalities on ADC or FLAIR images. There was one hyperintense focus in the left putamen on the DWI trace image, but the absence of ADC or FLAIR affirmation suggested it was artifact. Gross pathology and histopathology of this region did not detect any abnormalities. CONCLUSIONS Focal monopolar biphasic PFA of both healthy and chronically infarcted left ventricular myocardium does not generate any MB or cerebral emboli observable on ICE and brain MRI.
Collapse
Affiliation(s)
- Laith Alkukhun
- Knight Cardiovascular Institute, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 9723, USA
| | - Uday Sandhu
- Knight Cardiovascular Institute, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 9723, USA
| | - James Hodovan
- Knight Cardiovascular Institute, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 9723, USA
| | - Yan Zhao
- Knight Cardiovascular Institute, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 9723, USA
| | | | | | - Peter Stenzel
- Department of Pathology, Oregon Health & Science University, Portland, OR, USA
| | - Randy Woltjer
- Department of Pathology, Oregon Health & Science University, Portland, OR, USA
| | - Xin Li
- Advanced Imaging Research Center, Oregon Health & Science University, Portland, OR, USA
| | - Ramon F Barajas
- Advanced Imaging Research Center, Oregon Health & Science University, Portland, OR, USA
- Department of Radiology, Oregon Health & Science University, Portland, OR, USA
- Translational Oncology Program, Knight Cancer Institute, Oregon Health & Science University, Portland, OR, USA
| | - Babak Nazer
- Knight Cardiovascular Institute, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 9723, USA.
| |
Collapse
|
50
|
Abstract
Pulsed field ablation (PFA) was recently rediscovered as an emerging treatment modality for the ablation of cardiac arrhythmias. Ultra-short high voltage pulses are leading to irreversible electroporation of cardiac cells subsequently resulting in cell death. Current literature of PFA for pulmonary vein isolation (PVI) consistently reported excellent acute and long-term efficacy along with a very low adverse event rate. The undeniable benefit of the novel ablation technique is that cardiac cells are more susceptible to electrical fields whereas surrounding structures such as the pulmonary veins, the phrenic nerve or the esophagus are not, or if at all, minimally affected, which results in a favorable safety profile that is expected to be superior to the current standard of care without compromising efficacy. Nevertheless, the exact mechanisms of electroporation are not yet entirely understood on a cellular basis and pulsed electrical field protocols of different manufactures are not comparable among one another and require their own validation for each indication. Importantly, randomized controlled trials and comparative data to current standard of care modalities, such as radiofrequency- or cryoballoon ablation, are still missing. This review focuses on the "pearls" and "pitfalls" of PFA, a technology that has the potential to become the future leading energy source for PVI and beyond.
Collapse
Affiliation(s)
- Stefan Hartl
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany
| | - Nico Reinsch
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany
| | - Anna Füting
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany
| | - Kars Neven
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany
- Department of Medicine, Witten/Herdecke University, Witten, Germany.
| |
Collapse
|