1
|
Stonys R, Vitkus D. A survey on the practice of phlebotomy in Lithuania and adherence to the EFLM-COLABIOCLI recommendations: continuous training and clear standard operating procedures as tools for better quality. Biochem Med (Zagreb) 2024; 34:020702. [PMID: 38665875 PMCID: PMC11042562 DOI: 10.11613/bm.2024.020702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 01/17/2024] [Indexed: 04/28/2024] Open
Abstract
Introduction The aim of this study was to determine the level of compliance of venous blood sampling (VBS) in Lithuania with the joint recommendations of the European Federation of Clinical Chemistry and Laboratory Medicine and the Latin American Confederation of Clinical Biochemistry (EFLM-COLABIOCLI) and to analyse possible causes of errors. A survey was conducted between April and September 2022. Materials and methods A self-designed questionnaire was distributed to the Lithuanian National Societies. Error frequencies and compliance score were computed. Differences between groups were analysed using Pearson's chi-square, Fisher's exact criterion, Mann-Whitney U (for two groups), or Kruskal-Wallis (for more than two groups) for categorical and discrete indicators. The association between ordinal and discrete variables was assessed using Spearman's rank correlation coefficient. Statistical significance was determined at P < 0.05. Results A total of 272 respondents completed the questionnaire. Median error rate and compliance score were 31.5% and 13/19, respectively. Significant differences were found among professional titles, standard operating procedures availability, training recency, and tourniquet purpose opinions. A negative correlation was noted between compliance and time since training (rs = - 0.28, P < 0.001). Conclusions The findings of this study indicate that there is a significant need for improvement in compliance with the EFLM-COLABIOCLI recommendations on VBS among specialists in Lithuania. Essential measures include prioritizing ongoing phlebotomy training and establishing national guidelines. Harmonisation of blood collection practices across healthcare institutions is crucial.
Collapse
Affiliation(s)
- Ricardas Stonys
- Institute of Biomedical Sciences of the Faculty of Medicine, Vilnius University, Vilnius, Lithuania
- Centre of Laboratory Medicine of Vilnius University Hospital Santaros Klinikos, Vilnius, Lithuania
| | - Dalius Vitkus
- Institute of Biomedical Sciences of the Faculty of Medicine, Vilnius University, Vilnius, Lithuania
- Centre of Laboratory Medicine of Vilnius University Hospital Santaros Klinikos, Vilnius, Lithuania
| |
Collapse
|
2
|
Stonys R, Vitkus D. Assessing Non-Laboratory Healthcare Professionals' Attitude towards the Importance of Patient Preparation for Laboratory Tests. Healthcare (Basel) 2024; 12:989. [PMID: 38786400 PMCID: PMC11120851 DOI: 10.3390/healthcare12100989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/21/2024] [Accepted: 05/08/2024] [Indexed: 05/25/2024] Open
Abstract
(1) Background: Various guidelines address patient preparation and its importance for venous blood sampling, such as the GP41 guideline issued by the Clinical Laboratory Standards Institute (CLSI) and the blood collection guidelines published by the World Health Organisation. Recommendations provided by national societies or international organisations in the field of radiology, such as The Contrast Media Safety Committee of the European Society of Urogenital Radiology, or in the field of laboratory medicine, such as the Working Group for Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and the Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin American Confederation of Clinical Biochemistry (COLABIOCLI), also guide this practice. There is a notable lack of understanding regarding the viewpoints held by non-laboratory healthcare professionals concerning the significance of patient preparation for laboratory testing and the impact of typical factors associated with patient preparation. This study endeavours to bridge this gap by assessing the attitude of non-laboratory healthcare professionals in Lithuania regarding these pivotal aspects. (2) Methods: A self-designed anonymous questionnaire was disseminated among 141 public healthcare institutions in Lithuania. The internal consistency of the questionnaire was evaluated by computing Cronbach's alpha. Descriptive statistics were utilised for the variables, while comparisons of attitude among groups were conducted using Mann-Whitney U (for two groups) or Kruskal-Wallis (for more than two groups) for categorical and discrete indicators. The Kruskal-Wallis post-hoc test was employed for pairwise comparisons. A significance level of p-Value < 0.05 was applied to establish statistical significance. (3) Results: A total of 158 respondents constituted two distinct groups of healthcare professionals: nurses and physicians. Most of the participants either agreed or strongly agreed that patient preparation could introduce bias into laboratory test results. Professionals with less than 20 years of work experience or those who attended training in patient preparation for sampling within a 5-year timeframe exhibited stronger agreement regarding different preanalytical factors in patient preparation and their impact on laboratory test results compared to their counterparts. (4) Conclusions: Non-laboratory healthcare professionals who participated in this survey consider proper patient preparation for laboratory testing to be a significant step towards obtaining accurate test results. They also recognize the commonly acknowledged preanalytical factors as important for ensuring reliable test results. However, attitudes towards the importance of several preanalytical factors vary depending on whether non-laboratory healthcare professionals have more or less than 20 years of work experience, as well as whether they have attended any training on this topic within the last five years or have never attended such training.
Collapse
Affiliation(s)
- Ričardas Stonys
- Department of Physiology, Biochemistry, Microbiology and Laboratory Medicine, Institute of Biomedical Sciences, Faculty of Medicine, Vilnius University, M.K. Ciurlionio str. 21, LT-03101 Vilnius, Lithuania;
- Centre of Laboratory Medicine, Vilnius University Hospital Santaros Klinikos, Santariskiu str. 2, LT-08406 Vilnius, Lithuania
| | - Dalius Vitkus
- Department of Physiology, Biochemistry, Microbiology and Laboratory Medicine, Institute of Biomedical Sciences, Faculty of Medicine, Vilnius University, M.K. Ciurlionio str. 21, LT-03101 Vilnius, Lithuania;
- Centre of Laboratory Medicine, Vilnius University Hospital Santaros Klinikos, Santariskiu str. 2, LT-08406 Vilnius, Lithuania
| |
Collapse
|
3
|
Cigula Kurajica V, Vogrinc Ž, Turčić A, Galić S. Determination of cystatin C reference interval for children in Croatia. Biochem Med (Zagreb) 2024; 34:010702. [PMID: 38125620 PMCID: PMC10731735 DOI: 10.11613/bm.2024.010702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 09/27/2023] [Indexed: 12/23/2023] Open
Abstract
Introduction Cystatin C is considered an early marker of kidney damage. The aim was to determine the reference interval in children since this information was not available from the test manufacturer. Materials and methods Included were children aged 0 to 18 years undergoing routine check without history of any renal disease. Cystatin C was measured by the immunoturbidimetric method, and creatinine by the enzymatic method on a Cobas c501 analyzer (Roche Diagnostics, Manheim, Germany). Reference intervals were determined according to the CLSI C28-A3 guidelines using a robust method and a nonparametric percentile method, depending on the sample size. The Schwartz's formula was applied to estimate glomerular filtration (eGFR) from cystatin C. Results The cystatin C reference interval for children aged 1-18 years (N = 204, median 8 years) was from 0.61 mg/L (90% CI: 0.53 to 0.64) to 1.08 mg/L (90% CI: 1.07 to 1.14). Differences according to sex were not found. For children aged 0-1 years (N = 29, median 5 months), the reference interval was from 0.60 mg/L (90% CI: 0.48 to 0.72) to 1.49 mg/L (90% CI: 1.36 to 1.61). The sample size was too small to test the difference according to sex. The eGFR was 76 (70-88) mL/min/1.73m2 for males and 83 (74-92) mL/min/1.73m2 for females. Conclusion The cystatin C reference intervals for Croatian pediatric population according to age were determined. The cystatin C concentrations in children reach adulthood values after the first year. The cystatin C Schwartz's formula is applicable for eGFR calculation in children.
Collapse
Affiliation(s)
- Vlasta Cigula Kurajica
- Department for Laboratory Diagnostics, University Hospital Centre Zagreb, Zagreb, Croatia
| | - Željka Vogrinc
- Department for Laboratory Diagnostics, University Hospital Centre Zagreb, Zagreb, Croatia
| | - Ana Turčić
- Department for Laboratory Diagnostics, University Hospital Centre Zagreb, Zagreb, Croatia
| | - Slobodan Galić
- Department of Pediatrics, University Hospital Centre Zagreb, Zagreb, Croatia
| |
Collapse
|
4
|
Bukvić F, Ivković A, Čičak H, Dukić L, Šimundić AM, Marijančević D, Pašalić D. The Association of Serum Calprotectin with Fitness Indicators and Biochemical Markers in High-Level Athletes: A Continuous Dynamic Monitoring during One Competitive Season. Sports (Basel) 2023; 11:243. [PMID: 38133110 PMCID: PMC10748013 DOI: 10.3390/sports11120243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/29/2023] [Accepted: 12/12/2023] [Indexed: 12/23/2023] Open
Abstract
The objective was to determine the associations between several biochemical indicators and the dynamics of concentration change across four physical fitness phases over the period of a competitive season. Furthermore, associations between serum calprotectin and biomarkers of inflammation or muscle injury and physical indicators were examined. SUBJECTS AND METHODS Twenty professional male water polo players (median age: 28 (22-42)) were included in this study. Serum creatine kinase activity was determined by the automated photometric UV method. The concentrations of calprotectin, C-reactive protein, and myoglobin were measured using an automated immunoturbidimetric method, while an automated immunochemistry method was employed for interleukin-6, troponin I, and cortisol determination. Tests of repeated strength, maximal strength, and static strength were used to evaluate physical activity. RESULTS Serum calprotectin concentrations expressed in median and IQR were significantly different: T1: 2.92 g/mL (2.47; 3.86); T2: 2.35 g/mL (1.26; 2.87); T3: 2.27 g/mL (1.60; 3.27); and T4: 1.47 g/mL (1.04; 2.85) (p = 0.004). Cortisol concentration and CK activity showed significant changes among phases (p = 0.049 and p = 0.014, respectively). Each physical activity examined showed a significant seasonal decrease (all p values were 0.001). Calprotectin serum concentration and indicators of muscular injury, inflammation, and physical activity were found to be correlated during particular stages of the seasonal examination. CONCLUSIONS Calprotectin values determined throughout one competitive season decreased as training intensity among water polo players increased. Serum calprotectin concentrations and indicators were related to biochemical markers of inflammation and muscle damage.
Collapse
Affiliation(s)
- Frane Bukvić
- Department of Orthopedics and Trauma Surgery, University Hospital ‘Sveti Duh’, 10000 Zagreb, Croatia; (F.B.); (A.I.)
| | - Alan Ivković
- Department of Orthopedics and Trauma Surgery, University Hospital ‘Sveti Duh’, 10000 Zagreb, Croatia; (F.B.); (A.I.)
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Helena Čičak
- Department of Medical Laboratory Diagnostics, University Hospital ‘Sveti Duh’, 10000 Zagreb, Croatia; (H.Č.); (L.D.); (A.-M.Š.)
| | - Lora Dukić
- Department of Medical Laboratory Diagnostics, University Hospital ‘Sveti Duh’, 10000 Zagreb, Croatia; (H.Č.); (L.D.); (A.-M.Š.)
| | - Ana-Maria Šimundić
- Department of Medical Laboratory Diagnostics, University Hospital ‘Sveti Duh’, 10000 Zagreb, Croatia; (H.Č.); (L.D.); (A.-M.Š.)
- Faculty of Pharmacy and Biochemistry, University of Zagreb, 10000 Zagreb, Croatia
| | - Domagoj Marijančević
- Department of Clinical Chemistry, University Hospital Centre ‘Sestre Milosrdnice’, 10000 Zagreb, Croatia;
| | - Daria Pašalić
- Department of Medical Chemistry, Biochemistry and Clinical Chemistry, School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| |
Collapse
|
5
|
Dey S, Rai N, Bansal A, Kumari B, Das B, Kumari A. A Knowledge, Attitude, and Practice (KAP) Study on Phlebotomy Among Nurses in a Tertiary Hospital in Patna, India. Cureus 2023; 15:e50372. [PMID: 38213333 PMCID: PMC10782220 DOI: 10.7759/cureus.50372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/11/2023] [Indexed: 01/13/2024] Open
Abstract
INTRODUCTION For most clinicians and nursing officers, laboratory testing is an unfamiliar part of medical caregiving, and ignorance may lead to serious avoidable errors. Phlebotomy, the first basic step towards laboratory testing, is to be taken seriously otherwise unnecessary repeat testing becomes mandatory. We hypothesized that there are some gaps in knowledge, attitude, and practice (KAP) among these nursing officers regarding practices of phlebotomy, which may influence the quality of blood samples. This study aims to assess the overall nurses' knowledge, attitude, and practice of phlebotomy to provide a remarkable improvement in blood sampling practice in our hospital. MATERIAL AND METHODS A prospective study was conducted involving nurses posted in different wards in All India Institute of Medical Sciences (AIIMS) Patna, India. A phlebotomy questionnaire was designed based on KAP on the clinical and laboratory standards of the WHO guidelines. A total of 30 questions were distributed among the nursing staff, 10 each from knowledge, attitude, and practice. Descriptive and logistic regression analyses were used to analyze the KAP levels and their influencing factors. All continuous variables were tested for normality conditions using the Shapiro-Wilk test and P>0.05 were considered for normality. RESULTS AND CONCLUSION The total average score of knowledge among the nurses was 7.62 (95%CI: 15.77-16.56). It was found that the nurses, on average, had a very strong positive attitude (93.36%). Regarding the distribution of practices of nurses, it was found that 87% had good practice as most of the positive practice items had high responses. The knowledge of phlebotomy among nurses was found to be satisfactory, except in a few areas. An education program on phlebotomy should be developed for nurses to improve and enhance their knowledge of phlebotomy.
Collapse
Affiliation(s)
- Soma Dey
- Biochemistry, All India Institute of Medical Sciences (AIIMS) Patna, Patna, IND
| | - Neha Rai
- Biochemistry, All India Institute of Medical Sciences (AIIMS) Patna, Patna, IND
| | - Akash Bansal
- Biochemistry, All India Institute of Medical Sciences (AIIMS) Gorakhpur, Gorakhpur, IND
| | - Bandana Kumari
- Biochemistry, All India Institute of Medical Sciences (AIIMS) Patna, Patna, IND
| | - Bankim Das
- Transfusion Medicine, All India Institute of Medical Sciences (AIIMS) Patna, Patna, IND
| | - Alka Kumari
- Biochemistry, All India Institute of Medical Sciences (AIIMS) Patna, Patna, IND
| |
Collapse
|
6
|
Korkut S, Ülker T, Güler S, Gürsoy Ş. Do different wiping techniques in phlebotomy have an effect on vessel visibility, procedural success, and phlebotomy-related complications? J Vasc Access 2023:11297298231164181. [DOI: 10.1177/11297298231164181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
Background: This study was conducted to evaluate the effects of different wiping techniques used in phlebotomy on vein visibility, procedural success, and phlebotomy-related complications. Materials and methods: This single-center, comparative, randomized study was conducted with 90 patients in the internal medicine clinic of a tertiary hospital. During the phlebotomy procedure, the phlebotomy site was wiped with circular technique in the Group-I, vertical technique in the Group-II, and vertical + circular technique in the Group-III. Results: There was a significant difference between the three groups in terms of vein visibility after wiping of the phlebotomy site ( p < 0.05). The time spent for blood sampling was shorter in the Groups I and II ( p > 0.05). In the 3-day follow-up after the blood sample was taken, the ecchymosis and hematoma rates of the groups were similar ( p > 0.05). Conclusions: Vertical wiping and vertical + circular wiping techniques used in the cleaning of the phlebotomy site increased the visibility of the vein compared to only circular wiping. The time spent for blood sampling was shorter in the vertical wiping and vertical + circular wiping groups.
Collapse
|
7
|
Guven B, Benice I, Can M. Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay? Biochem Med (Zagreb) 2023; 33:010901. [PMID: 36817854 PMCID: PMC9927728 DOI: 10.11613/bm.2023.010901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 01/01/2023] [Indexed: 02/05/2023] Open
Abstract
Introduction Blood samples having inappropriate volume are a substantial part of preanalytical errors. Inadequate sample volume for glycated haemoglobin (HbA1c) test may be a common problem of patients with diabetes mellitus having vascular changes. In this study, we compared HbA1c concentrations of underfilled and appropriately filled blood collection tubes. Materials and methods To compare HbA1c concentrations, blood samples were collected into 2 mL tubes containing K3-EDTA from 109 subjects. Two blood samples (underfilled and appropriately filled) were drawn from a patient by the same personnel and materials. HbA1c measurements were assayed on a Cobas 6000 analyser module c 501 (Roche Diagnostics, Mannheim, Germany). The HbA1c% results were compared by t-test and Wilcoxon's signed-rank statistical methods (SPSS Inc., Chicago, USA). Bias analysis was performed using Microsoft Excel 4.0. Results Underfilled samples were classified three groups (group 1, N = 44; group 2, N = 36; and group 3, N = 29) according to the filling ratio of the samples; 0.5 mL and below (< 25%), 0.5-1.0 mL (25-50%), and 1.0-2.0 mL (> 50%), respectively. When we compared underfilled tubes with pairing filled tubes, there was a statistically significant difference only with tubes filled less than 25% (P = 0.030). Furthermore, we have done bias analysis between paired tubes according to the diagnostic cut-off value of 6.5%. The bias was more prominent in up to 50% underfilled blood tubes (1.1%), when HbA1c concentrations were below the diagnostic cut-off of 6.5%. Conclusions We suggest that the blood tubes with EDTA for HbA1c measurement should be filled with at least 50% to avoid clinical variations.
Collapse
|
8
|
Zhong J, Chen J, Cao M, Fang L, Wang Z, Liao J, Chen D, Zhang X, Guo J, Zhao L, Zhou C. Elevated plasma intestinal fatty acid binding protein and aberrant lipid metabolism predict post-stroke depression. Heliyon 2022; 8:e11848. [DOI: 10.1016/j.heliyon.2022.e11848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 10/05/2022] [Accepted: 11/16/2022] [Indexed: 11/24/2022] Open
|
9
|
Mortality Prediction Using SaO 2/FiO 2 Ratio Based on eICU Database Analysis. Crit Care Res Pract 2021; 2021:6672603. [PMID: 34790417 PMCID: PMC8592728 DOI: 10.1155/2021/6672603] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 12/24/2020] [Accepted: 09/25/2021] [Indexed: 12/02/2022] Open
Abstract
Purpose PaO2 to FiO2 ratio (P/F) is used to assess the degree of hypoxemia adjusted for oxygen requirements. The Berlin definition of Acute Respiratory Distress Syndrome (ARDS) includes P/F as a diagnostic criterion. P/F is invasive and cost-prohibitive for resource-limited settings. SaO2/FiO2 (S/F) ratio has the advantages of being easy to calculate, noninvasive, continuous, cost-effective, and reliable, as well as lower infection exposure potential for staff, and avoids iatrogenic anemia. Previous work suggests that the SaO2/FiO2 ratio (S/F) correlates with P/F and can be used as a surrogate in ARDS. Quantitative correlation between S/F and P/F has been verified, but the data for the relative predictive ability for ICU mortality remains in question. We hypothesize that S/F is noninferior to P/F as a predictive feature for ICU mortality. Using a machine-learning approach, we hope to demonstrate the relative mortality predictive capacities of S/F and P/F. Methods We extracted data from the eICU Collaborative Research Database. The features age, gender, SaO2, PaO2, FIO2, admission diagnosis, Apache IV, mechanical ventilation (MV), and ICU mortality were extracted. Mortality was the dependent variable for our prediction models. Exploratory data analysis was performed in Python. Missing data was imputed with Sklearn Iterative Imputer. Random assignment of all the encounters, 80% to the training (n = 26690) and 20% to testing (n = 6741), was stratified by positive and negative classes to ensure a balanced distribution. We scaled the data using the Sklearn Standard Scaler. Categorical values were encoded using Target Encoding. We used a gradient boosting decision tree algorithm variant called XGBoost as our model. Model hyperparameters were tuned using the Sklearn RandomizedSearchCV with tenfold cross-validation. We used AUC as our metric for model performance. Feature importance was assessed using SHAP, ELI5 (permutation importance), and a built-in XGBoost feature importance method. We constructed partial dependence plots to illustrate the relationship between mortality probability and S/F values. Results The XGBoost hyperparameter optimized model had an AUC score of .85 on the test set. The hyperparameters selected to train the final models were as follows: colsample_bytree of 0.8, gamma of 1, max_depth of 3, subsample of 1, min_child_weight of 10, and scale_pos_weight of 3. The SHAP, ELI5, and XGBoost feature importance analysis demonstrates that the S/F ratio ranks as the strongest predictor for mortality amongst the physiologic variables. The partial dependence plots illustrate that mortality rises significantly above S/F values of 200. Conclusion S/F was a stronger predictor of mortality than P/F based upon feature importance evaluation of our data. Our study is hypothesis-generating and a prospective evaluation is warranted. Take-Home Points. S/F ratio is a noninvasive continuous method of measuring hypoxemia as compared to P/F ratio. Our study shows that the S/F ratio is a better predictor of mortality than the more widely used P/F ratio to monitor and manage hypoxemia.
Collapse
|
10
|
Radovčić MK, Ljubičić J, Očić T, Jukić I, Vuk T. Blood collection failures from a blood establishment perspective. Transfus Med 2021; 31:88-93. [PMID: 33458900 DOI: 10.1111/tme.12762] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 01/04/2021] [Indexed: 01/26/2023]
Abstract
OBJECTIVES The objective of this study was to show experience of the Croatian Institute of Transfusion Medicine in monitoring and analysing collection failures caused by the venepuncture technique or occurred as a result of adverse reactions and complications experienced by donors during donation. BACKGROUND Collection failures represent one of the leading nonconformities in blood establishments. Apart from being a negative motivating factor for blood donors, they also affect the blood components supply and have a negative financial impact. METHODS Nonconformity records referring to collection failures were analysed retrospectively over a 6-year period (2013-2018) with regard to their frequency, causes, donor characteristics (age, gender, number of donations), place of occurrence (blood establishment, mobile sessions) and trends during the analysed period. RESULTS A total of 5166 collection failures out of 618 251 donations (0.84%) were recorded during the analysed period. The leading cause was haematoma at puncture site (1676, i.e., 32.4%). Collection failures which are primarily attributed to the venepuncture technique or vein selection accounted for 91% of all cases, whereas collection failures which occurred as a result of discontinued punctures due to adverse reactions in donors accounted for 9% of all cases. A much higher frequency of all collection failure types was recorded in female donors, whereas younger donors experienced adverse reactions more frequently (median age of 24). CONCLUSION The analysis and monitoring frequency of collection failures play an important role in planning of staff training activities, work organisation and timely implementation of corrective actions.
Collapse
Affiliation(s)
| | | | - Tihomir Očić
- Croatian Institute of Transfusion Medicine, Zagreb, Croatia
| | - Irena Jukić
- Croatian Institute of Transfusion Medicine, Zagreb, Croatia.,Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, Osijek, Croatia
| | - Tomislav Vuk
- Croatian Institute of Transfusion Medicine, Zagreb, Croatia
| |
Collapse
|
11
|
Delianu C, Moscalu M, Hurjui LL, Tărniceriu CC, Bădulescu OV, Lozneanu L, Hurjui I, Goriuc A, Surlari Z, Foia L. Chronometric vs. Structural Hypercoagulability. ACTA ACUST UNITED AC 2020; 57:medicina57010013. [PMID: 33379139 PMCID: PMC7823593 DOI: 10.3390/medicina57010013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/15/2020] [Accepted: 12/21/2020] [Indexed: 11/16/2022]
Abstract
Prolonged tourniquet stasis induced by venepuncture can lead to the release of the plasma of cell lysis products, as well as tissue factor (TF), impairing the quality of coagulation test results. The accidental presence of TF in vitro can trigger the coagulation mechanism, generating a false decrease in prothrombin time (PT). Background and Objectives: Identification of short PT tests below the normal reference value that could suggest a situation of hypercoagulability. The study aimed to compare the results of the shortened PT tests at their first determination with the eventual correction following duplication of the analysis from the same sample. Materials and methods: Identification of the shortened PT tests has been carried out for a period of 4 months, upon 544 coagulation samples referred to the Hematology department of Sf. Spiridon County Clinical Emergency Hospital from Iasi, Romania. Results: Out of the 544 samples of which the results indicated a state of hypercoagulability, by repeating the determination from the same sample, for 200 (36.76%) PT tests (p = 0.001) the value was corrected, falling within the normal reference range. For 344 (63.24%) tests, the results suggested a situation of hypercoagulability. Conclusions: In order to guarantee the highest quality of the laboratory services, a proper interpretation and report of the patients' results must be congruent and harmoniously associated to the actual clinical condition of the patient. Duplication of the PT determination from the same sample would exclude situations of false hypercoagulability and would provide significant improvement for the patient's safety.
Collapse
Affiliation(s)
- Carmen Delianu
- Department of Biochemistry, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (C.D.); (A.G.); (L.F.)
- Central Clinical Laboratory—Hematology Department, “Sf. Spiridon” County Clinical Emergency Hospital, 700111 Iasi, Romania
| | - Mihaela Moscalu
- Department of Preventive Medicine and Interdisciplinarity, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
- Correspondence: (M.M.); (L.L.H.)
| | - Loredana Liliana Hurjui
- Central Clinical Laboratory—Hematology Department, “Sf. Spiridon” County Clinical Emergency Hospital, 700111 Iasi, Romania
- Department of Morpho-Functional Sciences II, Discipline of Physiology, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania;
- Correspondence: (M.M.); (L.L.H.)
| | - Claudia Cristina Tărniceriu
- Department of Morpho-Functional Sciences I, Discipline of Anatomy, “Grigore T. Popa” University of Medicine and Pharmacy, Universității str. 16, 700115 Iasi, Romania;
- Hematology Clinic, “Sf. Spiridon” County Clinical Emergency Hospital, 700111 Iasi, Romania
| | - Oana-Viola Bădulescu
- Department of Morpho-Functional Sciences II, Discipline of Physiology, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania;
- Hematology Clinic, “Sf. Spiridon” County Clinical Emergency Hospital, 700111 Iasi, Romania
| | - Ludmila Lozneanu
- Department of Morpho-Functional Sciences I, Discipline of Histology, “Grigore T. Popa” University of Medicine and Pharmacy, Universității str. 16, 700115 Iasi, Romania;
- Department of Pathology, “Sf. Spiridon” Emergency County Hospital, 700111 Iasi, Romania
| | - Ion Hurjui
- Department of Morpho-Functional Sciences II, Discipline of Biophysics, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania;
| | - Ancuta Goriuc
- Department of Biochemistry, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (C.D.); (A.G.); (L.F.)
| | - Zinovia Surlari
- Department of Odontology and Parodontology, “Grigore T. Popa” University of Medicine and Pharmacy, Universității str. 16, 700115 Iasi, Romania;
| | - Liliana Foia
- Department of Biochemistry, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (C.D.); (A.G.); (L.F.)
- Central Clinical Laboratory—Biochemistry Department, “Sf. Spiridon” County Clinical Emergency Hospital, 700111 Iasi, Romania
| |
Collapse
|
12
|
Ruljancic N, Bakliza A, Vuk Pisk S, Geres N, Matic K, Ivezic E, Grosic V, Filipcic I. Antipsychotics-induced hyperprolactinemia and screening for macroprolactin. Biochem Med (Zagreb) 2020; 31:010707. [PMID: 33380894 PMCID: PMC7745162 DOI: 10.11613/bm.2021.010707] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 10/13/2020] [Indexed: 01/04/2023] Open
Abstract
Introduction High prolactin (PRL) concentrations are found in laboratory test results of patients on majority of antipsychotic drugs. Prevalence rates and degrees of severity of hyperprolactinemia (HPRL) based on PRL concentration may depend on the presence of macroprolactin in the serum. The aim of the study was to investigate the difference between PRL concentrations before and after precipitation of macroprolactin and to examine if there were any changes in the categorization of HPRL between samples prior and after precipitation. Materials and methods Total of 98 female patients (median age 33; range 19-47 years) diagnosed with a psychotic disorder, proscribed antipsychotic drugs, and with HPRL were included. Total PRL concentration and PRL concentration after macroprolactin precipitation with polyethylene glycol (postPEG-PRL) were determined by the chemiluminometric method on the Beckman Coulter Access2 analyser. Results Total PRL concentrations (median 1471; IQC: 1064-2016 mlU/L) and postPEG-PRL concentrations (median 1453; IQC: 979-1955 mlU/L) were significantly correlated using intraclass correlation coefficient for single measurements (mean estimation 0.96; 95%CI 0.93-0.97) and average measurement (mean estimation 0.98; 95%CI 0.96-0.99), and all investigated female patient had HPRL according to PRL and postPEG-PRL concentration. The median PRL recovery following PEG precipitation was 95; IQC: 90-100%. There was substantial agreement (kappa test = 0.859, 95% CI: 0.764-0.953) between the categories of HPRL severity based on total PRL concentrations and postPEG-PRL concentrations. Conclusion The study demonstrated that HPRL was present in all subjects using the reference interval for total PRL concentration and postPEG-PRL concentration with no significant impact of macroprolactin presence in the serum on the categorization of patients according to severity of HPRL.
Collapse
Affiliation(s)
- Nedjeljka Ruljancic
- Department of Laboratory Diagnostics, Psychiatric Hospital "Sveti Ivan" Zagreb, Croatia.,Faculty of Dental Medicine and Health, "Josip Juraj Strossmayer" University of Osijek, Osijek, Croatia
| | - Ana Bakliza
- Department of Laboratory Diagnostics, Psychiatric Hospital "Sveti Ivan" Zagreb, Croatia
| | - Sandra Vuk Pisk
- Faculty of Dental Medicine and Health, "Josip Juraj Strossmayer" University of Osijek, Osijek, Croatia.,Department of Integrative Psychiatry, Psychiatric Hospital 'Sveti Ivan' Zagreb, Croatia
| | - Natko Geres
- Faculty of Dental Medicine and Health, "Josip Juraj Strossmayer" University of Osijek, Osijek, Croatia.,Department of Integrative Psychiatry, Psychiatric Hospital 'Sveti Ivan' Zagreb, Croatia
| | - Katarina Matic
- Department of Integrative Psychiatry, Psychiatric Hospital 'Sveti Ivan' Zagreb, Croatia
| | - Ena Ivezic
- Faculty of Dental Medicine and Health, "Josip Juraj Strossmayer" University of Osijek, Osijek, Croatia.,Department of Integrative Psychiatry, Psychiatric Hospital 'Sveti Ivan' Zagreb, Croatia
| | - Vladimir Grosic
- Faculty of Dental Medicine and Health, "Josip Juraj Strossmayer" University of Osijek, Osijek, Croatia.,Department of Integrative Psychiatry, Psychiatric Hospital 'Sveti Ivan' Zagreb, Croatia
| | - Igor Filipcic
- Faculty of Dental Medicine and Health, "Josip Juraj Strossmayer" University of Osijek, Osijek, Croatia.,Department of Integrative Psychiatry, Psychiatric Hospital 'Sveti Ivan' Zagreb, Croatia.,School of Medicine, University of Zagreb, Zagreb, Croatia
| |
Collapse
|
13
|
The results of a close follow-up of trainees to gain a good blood collection practice. J Med Biochem 2020; 39:355-362. [PMID: 33269024 DOI: 10.2478/jomb-2019-0053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 11/03/2019] [Indexed: 01/31/2023] Open
Abstract
Background Phlebotomy is one of the most important steps in the preanalytical phase of a clinical laboratory process. In order to decrease phlebotomy errors, this specific procedure should be taught in detail by laboratory organizations. Our study aims to practice the training program on venous blood sampling and observe the close follow-up results. Methods In this observational study, 127 students who started their summer internship in Antalya Education and Research Hospital were given a one-day theoretical phlebotomy training in accordance with the Venous Blood Sampling Guidelines. After the theoretical training, phlebotomy applications of 10 students who were working in the field of out-patient blood sampling were observed both with and without their knowledge. A comprehensive checklist related to phlebotomy was created by the trainers in Antalya Education and Research Hospital and the observers answered each question as yes or no. For the statistical analysis, IBM SPSS Statistics 21.0 was used. Results After the theoretical education, the trainees were observed but no significant difference was found between the first and the second informed observations (p = 0.125). The students were observed three times more in the following week without their knowledge. There was a statistically significant difference between the first and the third unannounced observations (p=0.001). Conclusions In order to perform phlebotomy correctly, apart from theoretical education, a close follow-up is necessary too.
Collapse
|
14
|
Banković Radovanović P. Quality improvement project: Reducing non-conformities of the samples for haemostasis testing in a secondary healthcare centre through the nurses' education in phlebotomy. Biochem Med (Zagreb) 2020; 30:020708. [PMID: 32550816 PMCID: PMC7271753 DOI: 10.11613/bm.2020.020708] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 04/13/2020] [Indexed: 12/28/2022] Open
Abstract
Introduction Poor compliance to the current guidelines and lack of knowledge among nurses about proper blood sampling is set as the study hypothesis. Here is presented a quality improvement project with following aims: a) to identify the most prevalent non-conformity of the samples for haemostasis testing, b) to identify the cause of sample non-conformity, c) to perform corrective action(s) and d) to assess the effectiveness of the corrective action(s). Materials and methods The rate of non-conformity of samples collected for haemostasis tests was established for hospital wards with inpatients. Phlebotomy practice was audited throughout anonymous questionnaire among hospital’s nurses who perform phlebotomy. Education about blood sampling was performed as a 1-hour lecture in different small groups each working day within one month. Education effectiveness was assessed through the evaluation of sample quality and is considered effective if more than half of the hospital wards significantly reduced their sample non-conformities rate. Results Clotted sample constituted 84% of sample non-conformities. The questionnaire revealed nurses’ poor knowledge in phlebotomy. There was no difference in nurses’ knowledge regarding the level of education or work experience. Reduction in sample non-conformities was observed in 7 out of 9 wards 4 months after education; this improvement was statistically significant for 5 wards. Conclusion Clotted sample as the most prevalent non-conformity of the samples for haemostasis testing is caused by the lack of knowledge of the nurses in several parts of the phlebotomy process. Specific education of the motivated personnel in small groups was successful and long-term effective.
Collapse
|
15
|
Banković Radovanović P, Živković Mikulčić T, Simović Medica J. Unexpected abnormal coagulation test results in a 2-year-old child: A case report. Biochem Med (Zagreb) 2020; 30:011002. [PMID: 31839729 PMCID: PMC6904964 DOI: 10.11613/bm.2020.011002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 10/24/2019] [Indexed: 11/01/2022] Open
Abstract
Rejection of the sample with repeated blood withdrawal is always an unwanted consequence of sample nonconformity and preanalytical errors, especially in the most vulnerable population - children. Here is presented a case with unexpected abnormal coagulation test results in a 2-year-old child with no previously documented coagulation disorder. Child is planned for tympanostomy tubes removal under the anaesthesia driven procedure, and preoperative coagulation tests revealed prolonged prothrombin time, activated partial thromboplastin time and thrombin time, with fibrinogen and antithrombin within reference intervals. From the anamnestic and clinical data, congenital coagulation disorder was excluded, and with further investigation, sample mismatch, clot presence and accidental ingestion of oral anticoagulant, heparin contamination or vitamin K deficiency were excluded too. Due to suspected EDTA carryover during blood sampling another sample was taken the same day and all tests were performed again. The results for all tests were within reference intervals confirming EDTA effect on falsely prolongation of the coagulation times in the first sample. This case can serve as alert to avoid unnecessary loss in terms of blood withdrawal repetitions and discomfort of the patients and their relatives, tests repeating, prolonging medical procedures, and probably delaying diagnosis or proper medical treatment. It is the responsibility of the laboratory specialists to continuously educate laboratory staff and other phlebotomists on the correct blood collection as well as on its importance for the patient's safety.
Collapse
|
16
|
Pre-analytical Errors in Glucose Estimation Results in Query on Diabetic Management. Indian J Clin Biochem 2020; 35:32-42. [DOI: 10.1007/s12291-018-0782-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Accepted: 07/05/2018] [Indexed: 10/28/2022]
|
17
|
Hlapčić I, Somborac-Bačura A, Popović-Grle S, Vukić Dugac A, Rogić D, Rako I, Žanić Grubišić T, Rumora L. Platelet indices in stable chronic obstructive pulmonary disease - association with inflammatory markers, comorbidities and therapy. Biochem Med (Zagreb) 2019; 30:010701. [PMID: 31839721 PMCID: PMC6904969 DOI: 10.11613/bm.2020.010701] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 09/02/2019] [Indexed: 12/25/2022] Open
Abstract
Introduction Chronic obstructive pulmonary disease (COPD) is a complex inflammatory condition that can affect haemostasis. This study aimed to determine differences in platelet-related parameters between controls and COPD subjects. The hypothesis was that platelet indices are disturbed in COPD patients, and this would be accompanied by increased C-reactive protein (CRP), fibrinogen (Fbg) and white blood cells (WBC). Therefore, platelet count (Plt), platelet-related parameters - mean platelet volume (MPV), platelet distribution width (PDW), plateletcrit (Pct), their ratios (MPV/Plt, MPV/Pct, PDW/Plt, PDW/Pct), platelet to lymphocyte ratio (PLR), Plt index as well as CRP, Fbg and WBC were assessed. Materials and methods Study included 109 patients with stable COPD and 95 control subjects, recruited at Clinical Department for Lung Diseases Jordanovac, University Hospital Centre Zagreb (Zagreb, Croatia). Complete blood count was performed on Sysmex XN-1000, CRP on Cobas c501, and Fbg on BCS XP analyser. Data were analysed with MedCalc statistical software. Results Platelet (P = 0.007) and PLR (P = 0.006) were increased, while other platelet indices were decreased in COPD patients compared to controls. Combined model that included PLR, PDW and WBC showed great diagnostic performances, and correctly classified 75% of cases with an AUC of 0.845 (0.788 - 0.892), P < 0.001. Comorbidities (cardiovascular or metabolic diseases) had no effect on investigated parameters, while inhaled corticosteroids/long-acting β2-agonists (ICS/LABA) therapy increased MPV and PDW values in COPD patients. Conclusion Platelet indices were altered in COPD patients and they could be valuable as diagnostic markers of COPD development, especially if combined with already known inflammatory markers.
Collapse
Affiliation(s)
- Iva Hlapčić
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Anita Somborac-Bačura
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Sanja Popović-Grle
- University Hospital Centre Zagreb, Clinical Department for Lung Diseases Jordanovac, Zagreb, Croatia.,University of Zagreb, School of Medicine, Zagreb, Croatia
| | - Andrea Vukić Dugac
- University Hospital Centre Zagreb, Clinical Department for Lung Diseases Jordanovac, Zagreb, Croatia.,University of Zagreb, School of Medicine, Zagreb, Croatia
| | - Dunja Rogić
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia.,University Hospital Centre Zagreb, Clinical Institute of Laboratory Diagnostics, Zagreb, Croatia
| | - Ivana Rako
- University Hospital Centre Zagreb, Clinical Institute of Laboratory Diagnostics, Zagreb, Croatia
| | - Tihana Žanić Grubišić
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Lada Rumora
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| |
Collapse
|
18
|
Milevoj Kopcinovic L, Culej J, Jokic A, Bozovic M, Kocijan I. Laboratory testing of extravascular body fluids: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Part I - Serous fluids. Biochem Med (Zagreb) 2019; 30:010502. [PMID: 31839720 PMCID: PMC6904973 DOI: 10.11613/bm.2020.010502] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Accepted: 05/20/2019] [Indexed: 12/16/2022] Open
Abstract
Extravascular body fluids (EBF) analysis can provide useful information in the differential diagnosis of conditions that caused their accumulation. Their unique nature and particular requirements accompanying EBF analysis need to be recognized in order to minimize possible negative implications on patient safety. This recommendation was prepared by the members of the Working group for extravascular body fluid samples (WG EBFS). It is designed to address the total testing process and clinical significance of tests used in EBF analysis. The recommendation begins with a chapter addressing validation of methods used in EBF analysis, and continues with specific recommendations for serous fluids analysis. It is organized in sections referring to the preanalytical, analytical and postanalytical phase with specific recommendations presented in boxes. Its main goal is to assist in the attainment of national harmonization of serous fluid analysis and ultimately improve patient safety and healthcare outcomes. This recommendation is intended to all laboratory professionals performing EBF analysis and healthcare professionals involved in EBF collection and processing. Cytological and microbiological evaluations of EBF are beyond the scope of this document.
Collapse
Affiliation(s)
- Lara Milevoj Kopcinovic
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples.,Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Jelena Culej
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples.,Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Anja Jokic
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples.,Department of Medical Biochemistry, Haematology and Coagulation with Cytology, University Hospital for Infectious Diseases "Dr. Fran Mihaljević", Zagreb, Croatia
| | - Marija Bozovic
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples.,Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Irena Kocijan
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples.,Medical Biochemistry Laboratory, General hospital Varaždin, Varaždin, Croatia
| |
Collapse
|
19
|
Hlapčić I, Hulina-Tomašković A, Somborac-Bačura A, Rajković MG, Dugac AV, Popović-Grle S, Rumora L. Extracellular adenosine triphosphate is associated with airflow limitation severity and symptoms burden in patients with chronic obstructive pulmonary disease. Sci Rep 2019; 9:15349. [PMID: 31653924 PMCID: PMC6814706 DOI: 10.1038/s41598-019-51855-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Accepted: 10/09/2019] [Indexed: 12/16/2022] Open
Abstract
Extracellular adenosine triphosphate (eATP)-driven inflammation was observed in chronic obstructive pulmonary disease (COPD) but was not investigated in patients’ blood. Therefore, this study aimed to investigate eATP concentration in plasma of COPD patients and its association with disease severity and smoking. Study included 137 patients with stable COPD and 95 control subjects. eATP concentration was determined in EDTA plasma by luminometric method, and mRNA expression of eATP receptors P2X7R and P2Y2R was analysed by quantitative polymerase chain reaction (qPCR). eATP concentration was increased in COPD patients compared to controls (P < 0.001). Moreover, it was increasing with disease severity (GOLD 2–4) as well as symptoms burden and exacerbations history (GOLD A–D) (P < 0.05). eATP in healthy smokers differed from healthy non-smokers (P < 0.05) but was similar to GOLD 2 and GOLD A patients. eATP showed great diagnostic performances (OR = 12.98, P < 0.001) and correctly classified 79% of study participants. It demonstrated association with FEV1 and multicomponent indices (ADO, BODEx, BODCAT, CODEx, DOSE). Regarding gene expression, P2Y2R was increased in the blood of COPD patients. Plasma eATP could become a diagnostic and/or prognostic biomarker in COPD, as it seems to be associated with patients’ condition, quality of life and disease progression.
Collapse
Affiliation(s)
- Iva Hlapčić
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Andrea Hulina-Tomašković
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Anita Somborac-Bačura
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Marija Grdić Rajković
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Andrea Vukić Dugac
- University Hospital Centre Zagreb, Clinical Department for Lung Diseases Jordanovac, Zagreb, Croatia.,University of Zagreb, School of Medicine, Zagreb, Croatia
| | - Sanja Popović-Grle
- University Hospital Centre Zagreb, Clinical Department for Lung Diseases Jordanovac, Zagreb, Croatia.,University of Zagreb, School of Medicine, Zagreb, Croatia
| | - Lada Rumora
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Medical Biochemistry and Haematology, Zagreb, Croatia.
| |
Collapse
|
20
|
Bronić A, Coen Herak D, Margetić S, Milić M. Croatian Society of Medical Biochemistry and Laboratory Medicine: National recommendations for blood collection, processing, performance and reporting of results for coagulation screening assays prothrombin time, activated partial thromboplastin time, thrombin time, fibrinogen and D-dimer. Biochem Med (Zagreb) 2019; 29:020503. [PMID: 31223257 PMCID: PMC6559624 DOI: 10.11613/bm.2019.020503] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 08/07/2018] [Indexed: 12/20/2022] Open
Abstract
A modern diagnostic laboratory offers wide spectrum of coagulation assays utilized in the diagnosis and management of patients with haemostatic disorders, preoperative screening and anticoagulation therapy monitoring. The recent survey conducted among Croatian medical biochemistry and transfusion laboratories showed the existence of different practice policies in particular phases of laboratory process during coagulation testing and highlighted areas that need improvement. Lack of assay standardization together with non-harmonized test results between different measurement methods, can potentially lead to incorrect decisions in patient’s treatment. Consequently, patient safety could be compromised. Therefore, recommended procedures related to preanalytical, analytical and postanalytical phases of prothrombin time, activated partial thromboplastin time, thrombin time, fibrinogen and D-dimer testing are provided in this review, aiming to help laboratories to generate accurate and reliable test results.
Collapse
Affiliation(s)
- Ana Bronić
- Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Desiree Coen Herak
- Department of Laboratory Diagnostics, University Hospital Centre Zagreb, Zagreb, Croatia
| | - Sandra Margetić
- Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Marija Milić
- Department of Clinical Laboratory Diagnostics, Osijek University Hospital, Osijek, Croatia.,Faculty of Medicine, University of Osijek, Osijek, Croatia
| |
Collapse
|
21
|
Lippi G, von Meyer A, Cadamuro J, Simundic AM. Blood sample quality. ACTA ACUST UNITED AC 2019; 6:25-31. [PMID: 29794250 DOI: 10.1515/dx-2018-0018] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2018] [Accepted: 05/03/2018] [Indexed: 11/15/2022]
Abstract
Several lines of evidence now confirm that the vast majority of errors in laboratory medicine occur in the extra-analytical phases of the total testing processing, especially in the preanalytical phase. Most importantly, the collection of unsuitable specimens for testing (either due to inappropriate volume or quality) is by far the most frequent source of all laboratory errors, thus calling for urgent strategies for improving blood sample quality and managing data potentially generated measuring unsuitable specimens. A comprehensive overview of scientific literature leads us to conclude that hemolyzed samples are the most frequent cause of specimen non-conformity in clinical laboratories (40-70%), followed by insufficient or inappropriate sample volume (10-20%), biological samples collected in the wrong container (5-15%) and undue clotting (5-10%). Less frequent causes of impaired sample quality include contamination by infusion fluids (i.e. most often saline or glucose solutions), cross-contamination of blood tubes additives, inappropriate sample storage conditions or repeated freezing-thawing cycles. Therefore, this article is aimed to summarize the current evidence about the most frequent types of unsuitable blood samples, along with tentative recommendations on how to prevent or manage these preanalytical non-conformities.
Collapse
Affiliation(s)
- Giuseppe Lippi
- Section of Clinical Biochemistry, University Hospital of Verona, Piazzale LA Scuro, 37100 - Verona, Italy
| | - Alexander von Meyer
- Institute for Laboratory Medicine, Kliniken Nordoberpfalz AG and Klinikum St. Marien, Weiden and Amberg, Germany
| | - Janne Cadamuro
- Department of Laboratory Medicine, Paracelsus Medical University, Salzburg, Austria
| | - Ana-Maria Simundic
- Department of Medical Laboratory Diagnostics, University Hospital Sveti Duh, Zagreb, Croatia
| |
Collapse
|
22
|
Šostarić M, Bokulić A, Marijančević D, Zec I. Optimizing laboratory defined macroprolactin algorithm. Biochem Med (Zagreb) 2019; 29:020706. [PMID: 31223260 PMCID: PMC6559613 DOI: 10.11613/bm.2019.020706] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 03/21/2019] [Indexed: 11/24/2022] Open
Abstract
INTRODUCTION Macroprolactinaemia is a well-known analytical problem in diagnostics of hyperprolactinaemia usually detected with polyethylene glycol (PEG) precipitation method. Since there is no harmonization in macroprolactin detection and reporting results, this study proposes and evaluates the usefulness of in-house developed algorithm. The aims were to determine the most suitable way of reporting results after PEG treatment and the possibilities of rationalizing the precipitation procedure. MATERIALS AND METHODS This is a retrospective study based on extracted data for 1136 patients. Prolactin concentrations were measured before and after PEG precipitation on Roche cobas e601. Macroprolactinaemia was defined by percentage recovery and post-PEG prolactin concentrations. RESULTS Prevalence of macroprolactinaemia using recovery criteria of ≤ 40%, ≤ 60%, and post-PEG prolactin concentrations was 3.3%, 8.8% and 7.8%, respectively. Raising the cut-off value from the upper limit of the manufacturer's reference interval to 32.9 µg/L does not drastically change detected macroprolactinaemia with recovery criteria. Post-PEG prolactin concentrations showed more than half of the patients with macroprolactinaemia would be overlooked. Regardless of the criteria, a cut-off of 47.0 µg/L would miss most of the macroprolactinaemic patients. Repeated recovery measurements of follow-up patients showed there is a significant difference with mean absolute bias of 9%. CONCLUSIONS Post-PEG prolactin concentration with corresponding reference interval is the most suitable way of reporting results. All samples with prolactin concentration above the upper limit of the manufacturer's reference interval should be submitted to PEG precipitation. Follow-up period could be prolonged since the difference between the recoveries of repeated measurements is not clinically significant.
Collapse
Affiliation(s)
- Milica Šostarić
- Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia
| | - Adriana Bokulić
- Laboratory of Endocrinology, Clinic of Oncology and Nuclear Medicine, Sestre Milosrdnice University Hospital Center, Zagreb, Croatia
| | - Domagoj Marijančević
- Laboratory of Endocrinology, Clinic of Oncology and Nuclear Medicine, Sestre Milosrdnice University Hospital Center, Zagreb, Croatia
| | - Ivana Zec
- Laboratory of Endocrinology, Clinic of Oncology and Nuclear Medicine, Sestre Milosrdnice University Hospital Center, Zagreb, Croatia
| |
Collapse
|
23
|
Saracevic A, Dukic L, Simundic AM. Haemolysis and lipemia interfere with resistin and myeloperoxidase BioVendor ELISA assays. Biochem Med (Zagreb) 2019; 29:020703. [PMID: 31015785 PMCID: PMC6457919 DOI: 10.11613/bm.2019.020703] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 02/23/2019] [Indexed: 12/02/2022] Open
Abstract
Introduction The aim of our study was to investigate the influence of haemolysis and lipemia on resistin (RES) and myeloperoxidase (MPO) measurement by BioVendor enzyme-linked immunosorbent assays (ELISA). Materials and methods Blood was taken from healthy volunteers into lithium heparin tubes. Plasma samples were spiked with Lipofundin® emulsion (B. Braun Melsungen AG, Germany) for lipemia interference testing. Haemolysed samples were obtained by drawing aliquots of heparinized blood through a 26 gauge needle. Index of haemolysis (H), lipemia (L) and triglyceride concentration were measured on Abbott Architect c8000. Haemoglobin concentration was measured on Sysmex XN-1000. Concentrations of RES and MPO in all samples were determined with RES and MPO ELISA kits (BioVendor, Czech Republic). All measurements were performed in triplicate. Biases from the native samples were calculated for both analytes and compared with an arbitrary value (e.g. ± 10%). Results Triglyceride concentration in the investigated samples ranged from 0.57 to 38.23 mmol/L, which corresponds to L index from - 0.01 to 13.77. Haemoglobin concentration in all samples ranged from 0 to 8 g/L which correspond to H index from 0.05 to 8.77. Both MPO and RES showed significant biases at 1 g/L haemoglobin (58.7% and 66.7%, respectively). Also, both MPO and RES showed significant biases at 4.66 mmol/L triglycerides (33.8% and - 12.2%, respectively). Conclusions Resistin BioVendor assays are affected by haemolysis and lipemia already at low degree of interferent. Haemolysis was found to interfere at 1 g/L haemoglobin for both assays, while lipemia interferes at 4.66 mmol/L of triglycerides.
Collapse
Affiliation(s)
- Andrea Saracevic
- Department of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia
| | - Lora Dukic
- Department of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia
| | - Ana-Maria Simundic
- Department of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia
| |
Collapse
|
24
|
Pavlov M, Ćelap I. Plasminogen activator inhibitor 1 in acute coronary syndromes. Clin Chim Acta 2019; 491:52-58. [PMID: 30659821 DOI: 10.1016/j.cca.2019.01.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 01/14/2019] [Accepted: 01/15/2019] [Indexed: 11/24/2022]
Abstract
Plasminogen activator inhibitor 1 (PAI-1) is the main regulator of endogenous fibrinolysis, overriding the impact of other constituents of fibrinolysis. In plasma, it can be found in three forms: active, latent and inactive. There are numerous commercially available tests, analysing the activity of PAI-1 or the antigen level, with variable correlations between the two. PAI-1 has been extensively studied regarding incidence and outcomes of acute coronary syndromes, and showed positive association with both in numerous studies. Higher PAI-1 has been associated with worse short- and long-term outcomes. Studies are more consistent in the primary percutaneous coronary intervention era. Higher rise of PAI-1 within the first 24 h of acute myocardial infarction has been linked to some of its high-risk features. The circadian pattern of PAI-1 kinetics has been previously described, and the mechanisms behind this phenomenon and its impact on the incidence of acute coronary syndromes are well known. Further investigations are needed to test the safety and efficacy of PAI-1 as a pharmacological target in cardiovascular diseases.
Collapse
Affiliation(s)
- Marin Pavlov
- Department of Cardiology, Sestre milosrdnice University Hospital Centre, Vinogradska cesta 29, 10000 Zagreb, Croatia.
| | - Ivana Ćelap
- Department of Clinical Chemistry, Sestre milosrdnice University Hospital Centre, Vinogradska cesta 29, 10000 Zagreb, Croatia
| |
Collapse
|
25
|
Cornes M, Ibarz M, Ivanov H, Grankvist K. Blood sampling guidelines with focus on patient safety and identification – a review. Diagnosis (Berl) 2018; 6:33-37. [DOI: 10.1515/dx-2018-0042] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Accepted: 09/19/2018] [Indexed: 12/30/2022]
Abstract
Abstract
It has been well documented over recent years that the preanalytical phase is a leading contributor to errors in the total testing process (TTP). There has however been great progress made in recent years due to the exponential growth of working groups specialising in the field. Patient safety is clearly at the forefront of any healthcare system and any reduction in errors at any stage will improve patient safety. Venous blood collection is a key step in the TTP, and here we review the key errors that occur in venous phlebotomy process and summarise the evidence around their significance to patient safety. Recent studies have identified that patient identification and tube labelling are the steps that carry the highest risk with regard to patient safety. Other studies have shown that in 16.1% of cases, patient identification is incorrectly performed and that 56% of patient identification errors are due to poor labelling practice. We recommend that patient identification must be done using open questions and ideally three separate pieces of information. Labelling of the tube or linking the identity of the patient to the tube label electronically must be done in the presence of the patient whether it is before or after sampling. Combined this will minimise any chance of patient misidentification.
Collapse
Affiliation(s)
- Michael Cornes
- Clinical Chemistry Department , Worcester Acute Hospitals NHS Trust , Worcester , UK , Phone: +44-1905-760843
| | - Mercedes Ibarz
- Laboratory Medicine Department , University Hospital Arnau de Vilanova, IRBLleida , Lleida , Spain
| | | | - Kjell Grankvist
- Department of Medical Biosciences , Clinical Chemistry, Umeå University , Umea , Sweden
| |
Collapse
|
26
|
Wang J, He L, Sha J, Zhu H, Huang L, Zhu X, Dong J, Li G, Ge Z, Lu R, Ma G, Shi Y, Guo Y. Etiology and antimicrobial resistance patterns in pediatric urinary tract infection. Pediatr Int 2018; 60:418-422. [PMID: 29394522 DOI: 10.1111/ped.13526] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2017] [Revised: 12/19/2017] [Accepted: 01/29/2018] [Indexed: 11/30/2022]
Abstract
BACKGROUND Urinary tract infection (UTI) is one of most common pediatric infections. The aim of this study was to investigate the etiology and antimicrobial resistance patterns in children hospitalized at Children's Hospital of Nanjing Medical University. METHODS We conducted a retrospective, descriptive study of all UTI from 1 January 2013 to 30 November 2016 in children discharged from Nanjing Children's Hospital. The isolated pathogens and their resistance patterns were examined using midstream urine culture. RESULTS A total of 2,316 children with UTI were included in the study. The occurrence rates of isolated pathogens were as follows: Enterococcus spp., 35.15%; Escherichia coli, 22.32%; Staphylococcus aureus spp., 7.73%; Streptococcus spp., 7.51%; and Klebsiella spp., 6.95%. Uropathogens had a low susceptibility to linezolid (3.47%), vancomycin (0.92%), imipenem (5.74%), and amikacin (3.17%), but they had a high susceptibility to erythromycin (90.52%), penicillin G (74.01%), cefotaxime (71.41%), cefazolin (73.41%), cefuroxime (72.52%), and aztreonam (70.11%). CONCLUSIONS There is high antibiotic resistance in hospitalized children with UTI. Susceptibility testing should be carried out on all clinical isolates, and the empirical antibiotic treatment should be altered accordingly.
Collapse
Affiliation(s)
- Jun Wang
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Lijiao He
- Department of Clinical Laboratory, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Jintong Sha
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Haobo Zhu
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Liqu Huang
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Xiaojiang Zhu
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Jun Dong
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Guogen Li
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Zheng Ge
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Rugang Lu
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Geng Ma
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| | - Yaqi Shi
- School of Rehabilitation Medicine, Nanjing Medical University, Nanjing, China
| | - Yunfei Guo
- Department of Urology, Children's Hospital of Nanjing Medical University, Nanjing, China
| |
Collapse
|
27
|
Cai Q, Zhou Y, Yang D. Nurses' knowledge on phlebotomy in tertiary hospitals in China: a cross-sectional multicentric survey. Biochem Med (Zagreb) 2018; 28:010703. [PMID: 29187796 PMCID: PMC5701774 DOI: 10.11613/bm.2018.010703] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Accepted: 10/08/2017] [Indexed: 01/19/2023] Open
Abstract
Introduction In China, phlebotomy practice is mostly executed by nurses instead of phlebotomists. Our hypothesis was that these nurses may lack of knowledge on phlebotomy, especially factors influencing quality of blood samples. This study aims to assess the overall nurses’ knowledge on phlebotomy to provide reference for improving blood sampling practice in China. Materials and methods A survey was conducted involving nurses from 4 regions and 13 hospitals in China. A phlebotomy knowledge questionnaire was designed based on the Clinical and Laboratory Standards Institute H3-A6 guidelines, combining with the situations in China. Descriptive analysis and binary logistic regression analysis were used to analyze the knowledge level and its influencing factors. Results A total of 3400 questionnaires were distributed and 3077 valid questionnaires were returned, with an effective return rate of 90.5%. The correct rates of patient identification, hand sanitization, patient assessment, tube mixing time, needle disposing location and tube labelling were greater than 90%. However, the correct rates of order of draw (15.5%), definition of an inversion (22.5%), time to release tourniquet (18.5%) and time to change tube (28.5%) were relatively low. Binary logistic regression analysis showed that the correct rates of the aforementioned four questions were mainly related to the regional distribution of the hospitals (P < 0.001). Conclusions The knowledge level on phlebotomy among Chinese nurses was found unsatisfactory in some areas. An education program on phlebotomy should be developed for Chinese nurses to improve the consistency among different regions and to enhance nurse’s knowledge level on phlebotomy.
Collapse
Affiliation(s)
- Qian Cai
- School of Nursing, Zhejiang Chinese Medical University, Hangzhou, China
| | - Yunxian Zhou
- School of Nursing, Zhejiang Chinese Medical University, Hangzhou, China
| | - Dangan Yang
- Department of Laboratory Medicine, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
28
|
Perovic A, Nikolac N, Braticevic MN, Milcic A, Sobocanec S, Balog T, Dabelic S, Dumic J. Does recreational scuba diving have clinically significant effect on routine haematological parameters? Biochem Med (Zagreb) 2017; 27:325-331. [PMID: 28694723 PMCID: PMC5493166 DOI: 10.11613/bm.2017.035] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2016] [Accepted: 03/20/2017] [Indexed: 01/16/2023] Open
Abstract
Introduction Scuba diving represents a combination of exercise and changes in environmental conditions. This study aimed to evaluate changes in haematological parameters after recreational scuba diving in order to identify clinically significant changes. Materials and methods The study included males, 17 recreational divers, median age (range) 41 (30-52) years. Blood samples were taken before diving, immediately after diving to 30 meters for 30 minutes, 3 hours and 6 hours after diving. Complete blood counts were analyzed on the Cell Dyn Ruby haematology analyzer. Statistical significance between successive measurements was tested using Friedman test. The difference between the two measurements was judged against desirable bias (DSB) derived from biological variation and calculated reference change values (RCV). The difference higher than RCV was considered clinically significant. Results A statistically significant increase and difference judging against DSB was observed: for neutrophils immediately, 3 and 6 hours after diving (18%, 34% and 36%, respectively), for white blood cells (WBCs) 3 and 6 hours after diving (20% and 25%, respectively), for lymphocytes (20%) and monocytes (23%) 6 hours after diving. A statistically significant decrease and difference judging against DSB was found: immediately after diving for monocytes (- 15%), 3 and 6 hours after diving for red blood cells (RBCs) (- 2.6% and -2.9%, respectively), haemoglobin (- 2.1% and - 2.8%, respectively) and haematocrit (- 2.4% and - 3.2%, respectively). A clinically significant change was not found for any of the test parameters when compared to RCV. Conclusions Observed statistically significant changes after recreational scuba diving; WBCs, neutrophils, lymphocytes, monocytes increase and RBCs, haemoglobin, haematocrit decrease, probably will not affect clinical decision.
Collapse
Affiliation(s)
- Antonija Perovic
- Department of Laboratory Diagnostics, Dubrovnik General Hospital, Dubrovnik, Croatia
| | - Nora Nikolac
- University Department of Chemistry, Medical School University Hospital Sestre milosrdnice, Zagreb, Croatia
| | | | - Ana Milcic
- Department of Laboratory Diagnostics, Dubrovnik General Hospital, Dubrovnik, Croatia
| | - Sandra Sobocanec
- Division of Molecular Medicine, Rudjer Boskovic Institute, Zagreb, Croatia
| | - Tihomir Balog
- Division of Molecular Medicine, Rudjer Boskovic Institute, Zagreb, Croatia
| | - Sanja Dabelic
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Biochemistry and Molecular Biology, Zagreb, Croatia
| | - Jerka Dumic
- University of Zagreb, Faculty of Pharmacy and Biochemistry, Department of Biochemistry and Molecular Biology, Zagreb, Croatia
| |
Collapse
|
29
|
Lippi G, Simundic AM, Musile G, Danese E, Salvagno G, Tagliaro F. The alcohol used for cleansing the venipuncture site does not jeopardize blood and plasma alcohol measurement with head-space gas chromatography and an enzymatic assay. Biochem Med (Zagreb) 2017; 27:398-403. [PMID: 28694729 PMCID: PMC5493181 DOI: 10.11613/bm.2017.041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Accepted: 05/11/2017] [Indexed: 11/23/2022] Open
Abstract
Introduction This study aimed to establish whether an alcoholic antiseptic, wiped or not before venipuncture, may jeopardize alcohol testing with a commercial enzymatic assay and a reference head-space gas chromatography (GC) technique. Materials and methods Venous blood was collected from 23 healthy volunteers, with two sequential procedures. In the first blood collection, 2 mL of alcoholic antiseptic (0.5% chlorhexidine, 70% ethanol) were place on a gauge pad, the venipuncture site of right arm was cleaned but the antiseptic was not let to dry before phlebotomy. In the second blood collection, 2 mL of the same alcoholic antiseptic were placed on another gauge pad, the venipuncture site of left harm was cleaned and the antiseptic was accurately cleansed before phlebotomy. Ethanol was measured with a reference GC technique in whole blood and EDTA plasma, and a commercial enzymatic assay in EDTA plasma. Results No subject complained about feeling a particular itchy sensation when the alcohol was not wiped before puncturing the vein. The concentration of alcohol in all EDTA plasma samples was always lower than the limit of detection of the enzymatic assay (i.e., 2.2 mmol/L; 0.1 g/L). Similarly, alcohol concentration was also undetectable using a reference GC technique (i.e., < 0.22 mmol/L; 0.01 g/L) in EDTA plasma and whole blood. Conclusion It seems reasonable to conclude that using ethanol-containing antiseptics before venipuncture may not be causes of spurious or false positive results of alcohol measurement at least when ideal venipunctures can be performed.
Collapse
Affiliation(s)
- Giuseppe Lippi
- Working Group for Preanalytical Phase (WG-PRE), European Federation for Clinical Chemistry and Laboratory Medicine (EFLM).,Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Ana-Maria Simundic
- Working Group for Preanalytical Phase (WG-PRE), European Federation for Clinical Chemistry and Laboratory Medicine (EFLM).,Department of Medical Laboratory Diagnostics, University Hospital Sveti Duh, Zagreb, Croatia
| | - Giacomo Musile
- Department of Diagnostics and Public Health, Unit of Forensic Medicine, University of Verona, Verona, Italy
| | - Elisa Danese
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Gianluca Salvagno
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Franco Tagliaro
- Department of Diagnostics and Public Health, Unit of Forensic Medicine, University of Verona, Verona, Italy
| |
Collapse
|
30
|
Lippi G, Cervellin G. Acutely developing, spurious anaemia without actual blood loss. A paradigmatic case report. Biochem Med (Zagreb) 2017; 27:421-425. [PMID: 28694733 PMCID: PMC5493172 DOI: 10.11613/bm.2017.045] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 03/22/2017] [Indexed: 11/10/2022] Open
Abstract
We describe the case of a 55-year old women admitted at night to the emergency department (ED), complaining for acute abdominal pain lasting for nearly 5 hours. A first blood testing, performed immediately after admission, revealed mild anaemia. A second blood sample, drawn two hours after admission, revealed a considerable decrease of haemoglobin, haematocrit, total white blood cell and platelet counts (between 10-15% reduction). Abdominal ultrasonography was normal and the patient had no signs or symptoms of internal or external haemorrhage. Pre-analytical and analytical errors were accurately excluded. No infusion therapy was administered. After thoughtful discussing the sequence of events, it was ascertained that the first set of blood samples was drawn with the patient in seated position, immediately after ED admission (i.e., approximately 1 min passed from standing to seated position before venipuncture), whereas the second set of blood samples was drawn with the patient lying for two hours in supine position. This case report highlights the importance of standardizing patient position before venous blood collection, along with the crucial role played by cooperation and communication between laboratory and clinical wards for identifying and troubleshooting potential causes of spurious results of in vitro diagnostic testing.
Collapse
Affiliation(s)
- Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | | |
Collapse
|
31
|
Perovic E, Mrdjen A, Harapin M, Tesija Kuna A, Simundic AM. Diagnostic and prognostic role of resistin and copeptin in acute ischemic stroke. Top Stroke Rehabil 2017; 24:614-618. [DOI: 10.1080/10749357.2017.1367454] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Edi Perovic
- Department of Laboratory Diagnostics, General Hospital Zadar, Zadar, Croatia
| | | | - Mladen Harapin
- Department of Radiology, General Hospital Zadar, Zadar, Croatia
| | - Andrea Tesija Kuna
- Clinical Institute of Chemistry, University Hospital Center “Sestre Milosrdnice”, Zagreb, Croatia
| | - Ana-Maria Simundic
- Department of Medical Laboratory Diagnostics, Clinical Hospital “Sveti Duh”, Zagreb, Croatia
| |
Collapse
|
32
|
Saracevic A, Dukic L, Juricic G, Milevoj Kopcinovic L, Mirosevic G, Simundic AM. Various glycolysis inhibitor-containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them. ACTA ACUST UNITED AC 2017; 56:236-241. [DOI: 10.1515/cclm-2017-0279] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 06/29/2017] [Indexed: 01/16/2023]
Abstract
Abstract
Background:
The aim of our study was to determine the difference between glucose concentration measured 30 min after venipuncture in ice-chilled heparin plasma sample and all currently available citrate buffer-containing tubes (Greiner Glucomedics, Greiner FC Mix and Sarstedt GlucoEXACT) and still widely used sodium fluoride/potassium oxalate (NaF/Kox) tubes from Greiner.
Methods:
Blood was collected from 20 healthy volunteers and 20 patients with diabetes into LiH, NaF/KOx, Glucomedics, FC mix and GlucoEXACT tubes. Glucose was measured within 30 min from blood sampling in duplicate on the Architect c8000 analyzer. Mean biases between all tube types were calculated and compared to the recommended criteria (1.95%). Additionally, glucose concentrations measured in all five tube types were compared using the Friedman test.
Results:
In the entire studied population, glucose concentrations measured in Glucomedics, FC mix and GlucoEXACT were higher (7.3%, 3.2% and 2.0%, respectively) than in the ice-chilled LiH tubes. When all glycolysis inhibitor-containing tubes were compared, Glucomedics tubes significantly differed from GlucoEXACT and FC mix tubes (biases −4.9% and 4.0%, respectively). In addition, there was a significant difference between the NaF/KOx tube and Glucomedics, as well as FC mix tubes (biases 7.1% and 3.0%, respectively).
Conclusions:
Glucose concentrations measured in recommended ice-chilled lithium heparin- and citrate buffer-containing tubes are not comparable. Significant biases exist between various glycolysis inhibitor-containing tubes; therefore, they cannot be used interchangeably.
Collapse
Affiliation(s)
- Andrea Saracevic
- Department of Medical Laboratory Diagnostics , University Hospital “Sveti Duh” , Sveti Duh 64 , Zagreb , Croatia , Phone: +385 1 3712 117
| | - Lora Dukic
- Department of Medical Laboratory Diagnostics , University Hospital “Sveti Duh” , Zagreb , Croatia
| | - Gordana Juricic
- Department of Laboratory Diagnostics , General Hospital Pula , Pula , Croatia
| | - Lara Milevoj Kopcinovic
- University Department of Chemistry, University Hospital Center “Sestre Milosrdnice” , Zagreb , Croatia
| | - Gorana Mirosevic
- Department of Endocrinology, Diabetology and Metabolic diseases “Mladen Sekso” , University Hospital Center “Sestre Milosrdnice” , Zagreb , Croatia
| | - Ana-Maria Simundic
- Department of Medical Laboratory Diagnostics , University Hospital “Sveti Duh” , Zagreb , Croatia
| |
Collapse
|
33
|
Lima-Oliveira G, Volanski W, Lippi G, Picheth G, Guidi GC. Pre-analytical phase management: a review of the procedures from patient preparation to laboratory analysis. Scand J Clin Lab Invest 2017; 77:153-163. [PMID: 28266238 DOI: 10.1080/00365513.2017.1295317] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The pre-analytical phase encompasses all the procedures before the start of laboratory testing. This phase of the testing process is responsible for the majority of the laboratory errors, since the related procedures involve many sorts of non-laboratory professionals working outside the laboratory setting, thus without direct supervision by the laboratory staff. Therefore, either correct organization or management of both personnel and procedures that regard blood specimen collection by venipuncture are of fundamental importance, since the various steps for performing blood collection represent per se sources of laboratory variability. The aim of this (non-systematic) review addressed to healthcare professionals is to highlight the importance of blood specimen management (from patient preparation to laboratory analyses), as a tool to prevent laboratory errors, with the concept that laboratory results from inappropriate blood specimens are inconsistent and do not allow proper treatment nor monitoring of the patient.
Collapse
Affiliation(s)
- Gabriel Lima-Oliveira
- a Post-Graduate Program of Pharmaceutical Sciences, Department of Clinical Analyses , Federal University of Parana , Curitiba , Parana , Brazil
- b Laboratory of Clinical Biochemistry, Department of Neurosciences, Biomedicine and Movement Sciences , University of Verona , Italy
| | - Waldemar Volanski
- a Post-Graduate Program of Pharmaceutical Sciences, Department of Clinical Analyses , Federal University of Parana , Curitiba , Parana , Brazil
| | - Giuseppe Lippi
- b Laboratory of Clinical Biochemistry, Department of Neurosciences, Biomedicine and Movement Sciences , University of Verona , Italy
| | - Geraldo Picheth
- a Post-Graduate Program of Pharmaceutical Sciences, Department of Clinical Analyses , Federal University of Parana , Curitiba , Parana , Brazil
| | - Gian Cesare Guidi
- a Post-Graduate Program of Pharmaceutical Sciences, Department of Clinical Analyses , Federal University of Parana , Curitiba , Parana , Brazil
- b Laboratory of Clinical Biochemistry, Department of Neurosciences, Biomedicine and Movement Sciences , University of Verona , Italy
| |
Collapse
|
34
|
Giavarina D, Lippi G. Blood venous sample collection: Recommendations overview and a checklist to improve quality. Clin Biochem 2017; 50:568-573. [PMID: 28242283 DOI: 10.1016/j.clinbiochem.2017.02.021] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 02/18/2017] [Accepted: 02/24/2017] [Indexed: 12/26/2022]
Abstract
The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception.
Collapse
Affiliation(s)
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| |
Collapse
|
35
|
Lima-Oliveira G, Cesare Guidi G, Guimaraes AVP, Abol Correa J, Lippi G. Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil. J Med Biochem 2017; 36:39-43. [PMID: 28680348 PMCID: PMC5471658 DOI: 10.1515/jomb-2016-0032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2016] [Accepted: 11/01/2016] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The multifaceted clinical laboratory process is divided in three essential phases: the preanalytical, analytical and postanalytical phase. Problems emerging from the preanalytical phase are responsible for more than 60% of laboratory errors. This report is aimed at highlighting and discussing nonconformity (e.g., nonstandardized procedures) in primary blood tube mixing immediately after blood collection by venipuncture with evacuated tube systems. METHODS From January 2015 to December 2015, fifty different laboratory quality managers from Brazil were contacted to request their internal audit reports on nonconformity regarding primary blood tube mixing immediately after blood collection by venipuncture performed using evacuated tube systems. RESULTS AND CONCLUSIONS A minority of internal audits (i.e., 4%) concluded that evacuated blood tubes were not accurately mixed after collection, whereas more than half of them reported that evacuated blood tubes were vigorously mixed immediately after collection, thus magnifying the risk of producing spurious hemolysis. Despite the vast ma jority of centers declaring that evacuated blood tubes were mixed gently and carefully, the overall number of inversions was found to be different from that recommended by the manufacturer. Since the turbulence generated by the standard vacuum pressure inside the primary evacuated tubes seems to be sufficient for providing solubilization, mixing and stabilization between additives and blood during venipuncture, avoidance of primary tube mixing probably does not introduce a major bias in tests results and may not be considered a nonconformity during audits for accreditation.
Collapse
Affiliation(s)
- Gabriel Lima-Oliveira
- Section of Clinical Biochemistry, Department of Neurosciences, Biomedicine and Movement Sciences – University of Verona, Verona, Italy
- DICQ – National System of Accreditation, Brazilian Society of Clinical Analyses, Rio de Janeiro, Brazil
- PNCQ – Brazilian National Program of Quality Control, Rio de Janeiro, Brazil
| | - Gian Cesare Guidi
- Section of Clinical Biochemistry, Department of Neurosciences, Biomedicine and Movement Sciences – University of Verona, Verona, Italy
| | - Andre Valpassos Pacifici Guimaraes
- DICQ – National System of Accreditation, Brazilian Society of Clinical Analyses, Rio de Janeiro, Brazil
- PNCQ – Brazilian National Program of Quality Control, Rio de Janeiro, Brazil
| | - Jose Abol Correa
- PNCQ – Brazilian National Program of Quality Control, Rio de Janeiro, Brazil
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, Department of Neurosciences, Biomedicine and Movement Sciences – University of Verona, Verona, Italy
| |
Collapse
|
36
|
Juricic G, Saracevic A, Kopcinovic LM, Bakliza A, Simundic AM. The evidence for clinically significant bias in plasma glucose between liquid and lyophilized citrate buffer additive. Clin Biochem 2016; 49:1402-1405. [DOI: 10.1016/j.clinbiochem.2016.03.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 03/10/2016] [Accepted: 03/22/2016] [Indexed: 10/22/2022]
|
37
|
Dukić L, Kopčinović LM, Dorotić A, Baršić I. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochem Med (Zagreb) 2016; 26:318-336. [PMID: 27812301 PMCID: PMC5082214 DOI: 10.11613/bm.2016.036] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Accepted: 07/06/2016] [Indexed: 11/01/2022] Open
Abstract
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.
Collapse
Affiliation(s)
- Lora Dukić
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Committee for the Scientific Professional Development, Working Group for Blood Gas Testing; University Department of Chemistry, Medical School University Hospital Sestre milosrdnice, Zagreb, Croatia
| | - Lara Milevoj Kopčinović
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Committee for the Scientific Professional Development, Working Group for Blood Gas Testing; University Department of Chemistry, Medical School University Hospital Sestre milosrdnice, Zagreb, Croatia
| | - Adrijana Dorotić
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Committee for the Scientific Professional Development, Working Group for Blood Gas Testing; University Hospital for Infectious Diseases "Dr. Fran Mihaljević", Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Ivana Baršić
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Committee for the Scientific Professional Development, Working Group for Blood Gas Testing; Department of Laboratory Diagnostics, University Hospital Centre Zagreb, Croatia
| |
Collapse
|
38
|
Ialongo C, Bernardini S. Phlebotomy, a bridge between laboratory and patient. Biochem Med (Zagreb) 2016; 26:17-33. [PMID: 26981016 PMCID: PMC4783087 DOI: 10.11613/bm.2016.002] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Accepted: 12/06/2015] [Indexed: 12/28/2022] Open
Abstract
The evidence-based paradigm has changed and evolved medical practice. Phlebotomy, which dates back to the age of ancient Greece, has gained experience through the evolution of medicine becoming a fundamental diagnostic tool. Nowadays it connects the patient with the clinical laboratory dimension building up a bridge. However, more often there is a gap between laboratory and phlebotomist that causes misunderstandings and burdens on patient safety. Therefore, the scope of this review is delivering a view of modern phlebotomy to "bridge" patient and laboratory. In this regard the paper describes devices, tools and procedures in the light of the most recent scientific findings, also discussing their impact on both quality of blood testing and patient safety. It also addresses the issues concerning medical aspect of venipuncture, like the practical approach to the superficial veins anatomy, as well as the management of the patient's compliance with the blood draw. Thereby, the clinical, technical and practical issues are treated with the same relevance throughout the entire paper.
Collapse
Affiliation(s)
- Cristiano Ialongo
- Laboratory Medicine Department, "Tor Vergata" University Hospital, Rome, Italy
| | - Sergio Bernardini
- Laboratory Medicine Department, "Tor Vergata" University Hospital, Rome, Italy; Experimental Medicine and Surgery Department, "Tor Vergata" University, Rome, Italy
| |
Collapse
|
39
|
Dukic L, Jokic A, Kules J, Pasalic D. The knowledge and understanding of preanalytical phase among biomedicine students at the University of Zagreb. Biochem Med (Zagreb) 2016; 26:90-7. [PMID: 26981023 PMCID: PMC4783095 DOI: 10.11613/bm.2016.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Accepted: 09/23/2015] [Indexed: 11/01/2022] Open
Abstract
INTRODUCTION The educational program for health care personnel is important for reducing preanalytical errors and improving quality of laboratory test results. The aim of our study was to assess the level of knowledge on preanalytical phase in population of biomedicine students through a cross-sectional survey. MATERIALS AND METHODS A survey was sent to students on penultimate and final year of Faculty of Pharmacy and Biochemistry--study of medical biochemistry (FPB), Faculty of Veterinary Medicine (FVM) and School of Medicine (SM), University of Zagreb, Croatia, using the web tool SurveyMonkey. Survey was composed of demographics and 14 statements regarding the preanalytical phase of laboratory testing. Comparison of frequencies and proportions of correct answers was done with Fisher's exact test and test of comparison of proportions, respectively. RESULTS Study included 135 participants, median age 24 (23-40) years. Students from FPB had higher proportion of correct answers (86%) compared to students from other biomedical faculties 62%, P < 0.001. Students from FPB were more conscious of the importance of specimen mixing (P = 0.027), prevalence of preanalytical errors (P = 0.001), impact of hemolysis (P = 0.032) and lipemia interferences (P = 0.010), proper choice of anticoagulants (P = 0.001), transport conditions for ammonia sample (P < 0.001) and order of draw during blood specimen collection (P < 0.001), in comparison with students from SM and FVM. CONCLUSIONS Students from FPB are more conscious of the importance of preanalytical phase of testing in comparison with their colleagues from other biomedical faculties. No difference in knowledge between penultimate and final year of the same faculty was found.
Collapse
Affiliation(s)
- Lora Dukic
- University Department of Chemistry, Medical School University Hospital Sestre milosrdnice, Zagreb, Croatia
| | - Anja Jokic
- Medical-biochemical laboratory, Primary Health Care Centre Zagreb- East, Zagreb, Croatia
| | - Josipa Kules
- Department of Chemistry and Biochemistry, Faculty of Veterinary Medicine, University of Zagreb, Zagreb, Croatia
| | - Daria Pasalic
- Department of Medical Biochemistry, School of Medicine, University of Zagreb, Zagreb, Croatia
| |
Collapse
|
40
|
Ceriotti F. Harmonization Initiatives in Europe. EJIFCC 2016; 27:23-9. [PMID: 27683503 PMCID: PMC4975214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/30/2022]
Abstract
INTRODUCTION Modern medicine is more and more based on protocols and guidelines; clinical laboratory data play very often a relevant role in these documents and for this reason the need for their harmonization is increasing. To achieve harmonized results the harmonization process must not be limited to only the analytical part, but has to include the pre- and the post-analytical phases. RESULTS To fulfill this need the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has started several initiatives. A Working Group on harmonization of the total testing process (WG-H) has been created with the aims of: 1) surveying and summarizing national European and pan European harmonization initiatives; 2) promoting and coordinating the dissemination of especially promising harmonization initiatives among the EFLM member societies; and 3) taking initiatives to harmonize nomenclature, units and reference intervals at a European level. The activity of the WG started this year with a questionnaire targeted at surveying the status of various harmonization activities, especially those in the pre- and post-analytical phase categories, among the European laboratory medicine societies. CONCLUSIONS Based on the results of the questionnaire, some activities promoting the dissemination of best practice in blood sampling, sample storage and transportation, in collaboration with WG on the pre-analytical phase, will be promoted, and initiatives to spread to all the European countries the use of SI units in reporting, will be undertaken. Moreover, EFLM has created a Task and Finish Group on standardization of the color coding for blood collection tube closures that is actively working to accomplish this difficult task through collaboration with manufacturers.
Collapse
Affiliation(s)
- Ferruccio Ceriotti
- Laboratory Medicine Service, San Raffaele Hospital, Milano, Italy,Chair, EFLM WG-H (Working Group on Harmonisation of total testing process),Laboratory Medicine Service San Raffaele Hospital Via Olgettina 60 20132 Milano, Italy +39 02 26432282+39 02 26432640
| |
Collapse
|
41
|
Juricic G, Kopcinovic LM, Saracevic A, Bakliza A, Simundic AM. Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes. ACTA ACUST UNITED AC 2016; 54:363-71. [DOI: 10.1515/cclm-2015-0358] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 06/09/2015] [Indexed: 01/05/2023]
Abstract
AbstractGlucose measurements are crucial in diabetes diagnosis. We aimed to assess the effectiveness of liquid citrate acidification in preventing glycolysis and investigate glucose stability in serum, sodium fluoride (NaF/KOx) and Glucomedics tubes.Samples from 40 participants were collected in serum, lithium-heparin (LiH), sodium fluoride/potassium oxalate (NaF/KOx) and Glucomedics tubes. Glucose was measured within 60 min (baseline), 120 and 180 min from venipuncture. Serum, NaF/KOx and Glucomedics values at baseline were compared to LiH glucose concentration. Additionally, glucose values measured at 120 and 180 min from each tube were compared with the baseline value. Mean absolute bias for each tube and time point was calculated and compared to recommended criteria. The regression equation obtained comparing citrate to NaF/KOx tubes was used to recalculate glucose results retrieved from the laboratory information system.Glucose measured in Glucomedics was higher (9.9%; p<0.001), while glucose in NaF/KOx and serum was lower compared to LiH (2.4%; p<0.001 and 3.2%; p<0.001, respectively). Biases for all tubes were clinically significant. Glucose remained unchanged at room temperature in all tubes for up to 180 min after venipuncture. Observed bias caused by Glucomedics leads to a 10.6% increase in diabetes prevalence (p<0.001).Inhibition of glycolysis is most effectively achieved using liquid citrate acidification, compared to LiH, NaF/KOx or serum. Due to clinically significant bias relative to reference glucose, the interchangeable use of different tube types for serial glucose measurements is not recommended. The replacement of NaF/KOx with Glucomedics tubes substantially impacts glucose results, giving marked rise in diabetes prevalence.
Collapse
|
42
|
Plebani M. Harmonization in laboratory medicine: Requests, samples, measurements and reports. Crit Rev Clin Lab Sci 2015; 53:184-96. [DOI: 10.3109/10408363.2015.1116851] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
43
|
Milutinović D, Andrijević I, Ličina M, Andrijević L. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals. Biochem Med (Zagreb) 2015; 25:401-9. [PMID: 26527124 PMCID: PMC4622195 DOI: 10.11613/bm.2015.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 09/08/2015] [Indexed: 12/21/2022] Open
Abstract
INTRODUCTION This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis. MATERIALS AND METHODS A sample of 94 healthcare professionals (nurses and laboratory technicians) participated in this survey study. A four-section questionnaire was used as a research instrument comprising general information for research participants, knowledge on possible causes of in vitro hemolysis due to type of material used and venipuncture technique and specimen handling, as well as assessment of healthcare professionals' confidence level in their own ability to perform first and last venipuncture. RESULTS The average score on the knowledge test was higher in nurses' than in laboratory technicians (8.11±1.7, and 7.4±1.5, respectively). The difference in average scores was statistically significant (P=0.035) and Cohen's d in the range of 0.4 indicates that there is a moderate difference on the knowledge test among the health care workers. Only 11/94 of healthcare professionals recognized that blood sample collection from cannula and evacuated tube is method which contributes most to the occurrence of in vitro hemolysis, whereas most risk factors affecting occurrence of in vitro hemolysis during venipuncture were recognized. There were no significant differences in mean score on the knowledge test in relation to the confidence level in venipuncture (P=0.551). CONCLUSION Confidence level at last venipuncture among both profiles of healthcare staff was very high, but they showed insufficient knowledge about possible factors affecting hemolysis due to materials used in venipuncture compared with factors due to venipuncture technique and handling of blood sample.
Collapse
Affiliation(s)
| | - Ilija Andrijević
- University of Novi Sad; Faculty of Medicine; Department of Nursing, Serbia ; The Institute for Pulmonary Diseases of Vojvodina, Sremska Kamenica, Serbia
| | - Milijana Ličina
- University of Novi Sad; Faculty of Medicine; Department of Nursing, Serbia
| | - Ljiljana Andrijević
- University of Novi Sad; Faculty of Medicine; Department of Biochemistry, Serbia ; The Institute for Oncology of Vojvodina, Sremska Kamenica, Serbia
| |
Collapse
|
44
|
Krleza JL, Dorotic A, Grzunov A, Maradin M. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochem Med (Zagreb) 2015; 25:335-58. [PMID: 26524965 PMCID: PMC4622200 DOI: 10.11613/bm.2015.034] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Accepted: 09/08/2015] [Indexed: 11/05/2022] Open
Abstract
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.
Collapse
Affiliation(s)
- Jasna Lenicek Krleza
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working Group for Capillary Blood Sampling, Zagreb, Croatia ; Children's Hospital Zagreb, Department of Laboratory Diagnostics, Zagreb, Croatia
| | - Adrijana Dorotic
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working Group for Capillary Blood Sampling, Zagreb, Croatia ; University Hospital for Infectious Diseases Dr. Fran Mihaljevic, Department of Medical Biochemistry and Haematology, Zagreb, Croatia
| | - Ana Grzunov
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working Group for Capillary Blood Sampling, Zagreb, Croatia ; Children's Hospital Zagreb, Department of Laboratory Diagnostics, Zagreb, Croatia
| | - Miljenka Maradin
- Croatian Society of Medical Biochemistry and Laboratory Medicine, Working Group for Capillary Blood Sampling, Zagreb, Croatia ; General Hospital Karlovac, Department of Medical Biochemistry Laboratory, Karlovac, Croatia
| | | |
Collapse
|
45
|
Dorotić A, Antončić D, Biljak VR, Nedić D, Beletić A. Hemolysis from a nurses' standpoint--survey from four Croatian hospitals. Biochem Med (Zagreb) 2015; 25:393-400. [PMID: 26525069 PMCID: PMC4622201 DOI: 10.11613/bm.2015.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2015] [Accepted: 07/21/2015] [Indexed: 11/28/2022] Open
Abstract
INTRODUCTION Hemolysis can occur during sample collection, handling and transport. It is more frequent when the non-laboratory staff performs sampling. The aim of this study was to assess nurses' knowledge on the causes of hemolysis and consequential impact on the laboratory tests results. Additionally, the differences in knowledge, related to work experience, professional degree and previous education about hemolysis were explored. MATERIALS AND METHODS An anonymus survey, containing 11 questions on demographics, causes of hemolysis, its impact on biochemical parameters and nurses' attitude towards additional education in preanalytics, was conducted in four Croatian hospitals. The answers were compared by Chi-squared and Fischer exact test. RESULTS In total, 562 survey results were collected. Majority of nurses declared familiarity with the term "hemolysis" (99.6%). There were 77% of correct answers regarding questions about the causes of hemolysis, but only 50% when it comes to questions about interference in biochemical tests. The percentage of correct answers about causes was significantly lower (P=0.029) among more experienced nurses, and higher (P=0.027) in those with higher professional degree, while influence of previous education was not significant. Also, higher percentage of correct answers about interferences was encountered in nurses with longer work experience (P=0.039). More than 70% of nurses declared that additional education about preanalytical factors would be beneficial. CONCLUSION Croatian nurses are familiar with the definition of hemolysis, but a lack of knowledge about causes and influence on laboratory test results is evident. Nurses are eager to improve their knowledge in this field of preanalytical phase.
Collapse
Affiliation(s)
- Adrijana Dorotić
- Department of Medical Biochemistry and Hematology, University Hospital for Infectious Diseases "Dr. Fran Mihaljević", Zagreb, Croatia
| | - Dragana Antončić
- Clinical Institute of Laboratory Diagnostics, Clinical Hospital Centre Rijeka, Rijeka, Croatia
| | - Vanja Radišić Biljak
- Department of Medical Biochemistry and Laboratory Medicine, Merkur University Hospital, Zagreb, Croatia
| | - Dara Nedić
- Department of Laboratory Diagnostics, Clinical Hospital Centre Zagreb, Zagreb, Croatia
| | - Andjelo Beletić
- Center for Medical Biochemistry, Clinical Center of Serbia, Belgrade, Serbia
| |
Collapse
|
46
|
Questionable Reliability of Homocysteine as the Metabolic Marker for Folate and Vitamin B12 Deficiency in Patients with Chronic Obstructive Pulmonary Disease. J Med Biochem 2015; 34:467-472. [PMID: 28356857 PMCID: PMC4922360 DOI: 10.2478/jomb-2014-0046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2014] [Accepted: 04/26/2014] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND An increased homocysteine (Hcy) concentration may represent a metabolic marker of folate and vitamin B12 deficiency, both significant public health problems. For different reasons, patients with chronic obstructive pulmonary disease (COPD) are prone to these deficiencies. The study evaluates the reliability of Hcy concentration in predicting folate or vitamin B12 deficiency in these patients. METHODS A group of 50 COPD patients (28 males/22 females, age (χ̄±SD=49.0±14.5) years was enrolled. A chemiluminescent microparticle immunoassay was applied for homocysteine, folate and vitamin B12 concentration. Kolmogorov-Smirnov, Mann-Whitney U and χ2 tests, Spearman's correlation and ROC analysis were included in the statistical analysis, with the level of significance set at 0.05. RESULTS Average (SD) concentrations of folate and vitamin B12 were 4.13 (2.16) μg/L and 463.6 (271.0) ng/L, whereas only vitamin B12 correlated with the Hcy level (P=-0.310 (R=0.029)). Gender related differences were not significant and only a borderline significant correlation between age and folate was confirmed (R=0.279 (P=0.047)). The incidence of folate and vitamin B12 deficiency differed significantly (P=0.000 and P<0.000 for folate and vitamin B12 respectively), depending on the cutoff used for classification (4.4, 6.6 and 8.0 μg/L - folate; 203 and 473 ng/L - vitamin B12). ROC analyses failed to show any significance of hyperhomocysteinemia as a predictor of folate or vitamin B12 deficiency. CONCLUSION Reliability of the Hcy concentration as a biomarker of folate or vitamin B12 depletion in COPD patients is not satisfactory, so their deficiency cannot be predicted by the occurrence of HHcy.
Collapse
|
47
|
|
48
|
Nikolac N, Simundic AM, Kackov S, Serdar T, Dorotic A, Fumic K, Gudasic-Vrdoljak J, Klenkar K, Sambunjak J, Vidranski V. The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Clin Chim Acta 2015; 450:104-9. [PMID: 26253925 DOI: 10.1016/j.cca.2015.08.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Revised: 07/24/2015] [Accepted: 08/03/2015] [Indexed: 11/28/2022]
Abstract
INTRODUCTION The aim of this work was to evaluate to what extent the scope and content of information provided to patients is standardized across medical biochemistry laboratories in Croatia. MATERIALS AND METHODS Two on-line self-report surveys were sent out: Survey A regarding attitudes on importance of patient preparation and Survey B on the contents of patient preparation instructions. RESULTS 13/118 laboratories (11%) do not provide written instructions to patients on how to prepare for laboratory testing, and 36 (40%) do not include information about water intake in their instructions. Only half of laboratories provide instructions for prostate-specific antigen (53.8%), female sex hormones (53.7%) and therapeutic drug monitoring (TDM) (52.5%). Inadequate information about fasting status (55.0%) and 24 hour urine collection (77.9%) were frequent errors with high severity and were associated with the greatest potential to cause patient harm. CONCLUSIONS Laboratory professionals in Croatia have a positive attitude towards the importance of patient preparation for laboratory testing. However, the information for laboratory testing is not standardized and frequently lacks guidance for tests related to TDM, coagulation and endocrinology. This study highlights the need for standardized, updated and evidence-based recommendations for patient preparation in order to minimize the risk for patients.
Collapse
Affiliation(s)
- Nora Nikolac
- University Department of Chemistry, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia.
| | - Ana-Maria Simundic
- University Department of Chemistry, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Sanja Kackov
- Medical Biochemistry Laboratory, Policlinic Bonifarm, Zagreb, Croatia
| | - Tihana Serdar
- Clinical Department for Laboratory Diagnostics, University Hospital Dubrava, Zagreb, Croatia
| | - Adrijana Dorotic
- Department of Medical Biochemistry and Hematology, University Hospital for Infectious Diseases Dr. Fran Mihaljevic, Zagreb, Croatia
| | - Ksenija Fumic
- Department of Laboratory Diagnostics, University Hospital Center Zagreb, Zagreb, Croatia
| | | | - Kornelija Klenkar
- Medical Biochemistry Laboratory, General Hospital Zabok, Zabok, Croatia
| | - Jadranka Sambunjak
- Department of Laboratory Diagnostics, General Hospital Zadar, Zadar, Croatia
| | - Valentina Vidranski
- Department of Oncology and Nuclear Medicine, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| |
Collapse
|
49
|
Laboratory Diagnostics and Quality of Blood Collection. J Med Biochem 2015; 34:288-294. [PMID: 28356839 PMCID: PMC4922344 DOI: 10.2478/jomb-2014-0043] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Accepted: 04/17/2014] [Indexed: 12/02/2022] Open
Abstract
Diagnostic blood samples collected by phlebotomy are the most common type of biological specimens drawn and sent to laboratory medicine facilities for being analyzed, thus supporting caring physicians in patient diagnosis, follow-up and/or therapeutic monitoring. Phlebotomy, a relatively invasive medical procedure, is indeed critical for the downstream procedures accomplished either in the analytical phase made in the laboratory or in the interpretive process done by the physicians. Diagnosis, management, treatment of patients and ultimately patient safety itself can be compromised by poor phlebotomy quality. We have read with interest a recent article where the authors addressed important aspects of venous blood collection for laboratory medicine analysis. The authors conducted a phlebotomy survey based on the Clinical and Laboratory Standard Institute (CLSI) H03-A6 document (presently replaced by the GP41-A6 document) in three government hospitals in Ethiopia to evaluate 120 professionals (101 non-laboratory professionals vs. 19 laboratory professionals) as regards the venous blood collection practice. The aim of this mini (non-systematic) review is to both take a cue from the above article and from current practices we had already observed in other laboratory settings, and discuss four questionable activities performed by health care professionals during venous blood collection. We refer to: i) diet restriction assessment; ii) puncture site cleansing; iii) timing of tourniquet removal and; iv) mixing specimen with additives.
Collapse
|
50
|
Culjak M, Nikolac N, Simundic AM. Short-term storage stability of serum angiotensin-converting enzyme (ACE) activity. Clin Chim Acta 2015; 446:261-2. [PMID: 25957986 DOI: 10.1016/j.cca.2015.05.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Revised: 05/01/2015] [Accepted: 05/01/2015] [Indexed: 11/26/2022]
Affiliation(s)
- Marija Culjak
- University Department of Chemistry, Sestre Milosrdnice University Hospital, Zagreb, Croatia
| | - Nora Nikolac
- University Department of Chemistry, Sestre Milosrdnice University Hospital, Zagreb, Croatia.
| | - Ana-Maria Simundic
- University Department of Chemistry, Sestre Milosrdnice University Hospital, Zagreb, Croatia
| |
Collapse
|