1
|
Computational analysis of efficient organic solar cell-based retinal prosthesis using plasmonic gold nanoparticles. Front Cell Neurosci 2023; 17:1205048. [PMID: 37576567 PMCID: PMC10413124 DOI: 10.3389/fncel.2023.1205048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 07/17/2023] [Indexed: 08/15/2023] Open
Abstract
Introduction Photovoltaic restoration of vision, especially in conjunction with the use of silicon photodiodes, has gained attention for use in patients affected by blindness due to retinal layer disease. Although the use of silicon photodiodes offers miniaturization of the implant unit and increase in the stimulation channel, the implant unit may suffer from the fracture of these brittle photodiodes when mechanical pressure exerted. Methods We present an organic solar cell (OSC)-based retinal prosthesis in which spherical gold nanoparticles (AuNPs) are embedded into the active layer to increase the efficiency of the bioelectric interface. Results We demonstrate computationally that a modeled OSC incorporating spherical AuNPs has three times higher efficiency than that of a bare OSC presented before for retinal prostheses. Our AuNP based OSC was able to activate the neuron at the minimum light intensity of 0.26 mW/mm2, which is lower than that of the bare OSC. Discussion The use of AuNPs in OSC allows device miniaturization or lowering of the light exposure required for neural activation using a photovoltaic retinal prosthesis, which can generally be applied in a broad range of neural prostheses.
Collapse
|
2
|
Biocompatibility of a Conjugated Polymer Retinal Prosthesis in the Domestic Pig. Front Bioeng Biotechnol 2020; 8:579141. [PMID: 33195139 PMCID: PMC7605258 DOI: 10.3389/fbioe.2020.579141] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 09/18/2020] [Indexed: 12/18/2022] Open
Abstract
The progressive degeneration of retinal photoreceptors is one of the most significant causes of blindness in humans. Conjugated polymers represent an attractive solution to the field of retinal prostheses, and a multi-layer fully organic prosthesis implanted subretinally in dystrophic Royal College of Surgeons (RCS) rats was able to rescue visual functions. As a step toward human translation, we report here the fabrication and in vivo testing of a similar device engineered to adapt to the human-like size of the eye of the domestic pig, an excellent animal paradigm to test therapeutic strategies for photoreceptors degeneration. The active conjugated polymers were layered onto two distinct passive substrates, namely electro-spun silk fibroin (ESF) and polyethylene terephthalate (PET). Naive pigs were implanted subretinally with the active device in one eye, while the contralateral eye was sham implanted with substrate only. Retinal morphology and functionality were assessed before and after surgery by means of in vivo optical coherence tomography and full-field electroretinogram (ff-ERG) analysis. After the sacrifice, the retina morphology and inflammatory markers were analyzed by immunohistochemistry of the excised retinas. Surprisingly, ESF-based prostheses caused a proliferative vitreoretinopathy with disappearance of the ff-ERG b-wave in the implanted eyes. In contrast, PET-based active devices did not evoke significant inflammatory responses. As expected, the subretinal implantation of both PET only and the PET-based prosthesis locally decreased the thickness of the outer nuclear layer due to local photoreceptor loss. However, while the implantation of the PET only substrate decreased the ff-ERG b-wave amplitude with respect to the pre-implant ERG, the eyes implanted with the active device fully preserved the ERG responses, indicating an active compensation of the surgery-induced photoreceptor loss. Our findings highlight the possibility of developing a new generation of conjugated polymer/PET-based prosthetic devices that are highly biocompatible and potentially suitable for subretinal implantation in patients suffering from degenerative blindness.
Collapse
|
3
|
Transcorneal Electrical Stimulation for the Treatment of Retinitis Pigmentosa: A Multicenter Safety Study of the OkuStim® System (TESOLA-Study). Ophthalmic Res 2019; 63:234-243. [DOI: 10.1159/000505001] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 11/24/2019] [Indexed: 11/19/2022]
|
4
|
Transcorneal electrical stimulation for the treatment of retinitis pigmentosa: results from the TESOLAUK trial. BMJ Open Ophthalmol 2017; 2:e000096. [PMID: 29354722 PMCID: PMC5751865 DOI: 10.1136/bmjophth-2017-000096] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 09/30/2017] [Accepted: 10/09/2017] [Indexed: 01/24/2023] Open
Abstract
Objective To explore the impact of weekly transcorneal electrical stimulation (TES) over a 6-month period as a treatment for retinitis pigmentosa (RP). Methods and analysis A prospective open-label observational trial was carried out assessing weekly TES in participants with RP for a period of 6 months followed by observation for a further 6 months. Clinical examination and investigations were carried out at 3 monthly intervals for a total of 12 months. The primary outcome measure explored safety through a descriptive analysis of adverse effects with secondary outcome measures evaluating structural and functional efficacy. Results Seven male and seven female participants with RP aged 18–80 years were recruited. TES was well tolerated with no serious adverse events reported. Two participants reported transient foreign body sensation and one participant had discomfort underneath the skin electrode. Following 6 months of TES, best-corrected visual acuity increased by 1.1±1.4 letters in the control arm and 0.93±1.4 letters in the treated arm. Central microperimetry threshold sensitivity rose by 0.02±0.5 decibels (dB) and 0.37±0.4 dB and Goldmann visual field volume by 0.16±0.09 steradians (sr) vs 0.22±0.12 sr for the control and treated eye, respectively. There was no statistical significance seen between eyes following the treatment or observation period. Conclusion This small open-label clinical trial showed that TES was safe and well tolerated in patients with RP. Visual function measurements at 6 months demonstrated no significant difference between the control and treated eyes. The results justify a larger clinical trial over a longer period of time in order to identify any treatment effect.
Collapse
|
5
|
Long-term anesthetic protocol in rats: feasibility in electrophysiology studies in visual prosthesis. Vet Ophthalmol 2017; 21:290-297. [PMID: 29148158 DOI: 10.1111/vop.12507] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Electrical stimulation of excitable cells provides therapeutic benefits for a variety of medical conditions, including restoration of partial vision to those blinded via some types of retinal degeneration. To improve visual percepts elicited by the current technology, researchers are conducting acute electrophysiology experiments, mainly in cats. However, the rat can provide a model of a range of retinal diseases and possesses a sufficiently large eye to be used in this field. This article presents a long-term anesthetic protocol to enable electrophysiology experiments to further the development of visual prostheses. Six Long-Evans rats (aged between 14 and 16 weeks) were included in this study. Surgical anesthesia was maintained for more than 15 h by combining constant intravenous infusion of ketamine (24.0-34.5 mg/kg/h), xylazine (0.9-1.2 mg/kg/h), and inhaled isoflurane in oxygen (<0.5%). Overall heart rate, respiratory rate, and body temperature remained between 187-233 beats/min, 45-58 breaths/min, and 36-38 °C, respectively. Neural responses to 200-ms light pulses were recorded from the superior colliculus using a 32-channel neural probe at the beginning and before termination of the experiment. Robust responses were recorded from distinct functional types of retinal pathways. In addition, a platinum electrode was implanted in the retrobulbar space. The retina was electrically stimulated, and the activation threshold was determined to be 5.24 ± 0.24 μC/cm2 . This protocol may be used not only in the field of visual prosthesis research, but in other research areas requiring longer term acute experiments.
Collapse
|
6
|
Age-related changes in the spatiotemporal responses to electrical stimulation in the visual cortex of rats with progressive vision loss. Sci Rep 2017; 7:14165. [PMID: 29075008 PMCID: PMC5658441 DOI: 10.1038/s41598-017-14303-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 10/09/2017] [Indexed: 11/08/2022] Open
Abstract
The Royal College of Surgeons (RCS) rat gradually loses vision due to retinal degeneration. Previous physiological studies have depicted the progressive loss of optical responses in the visual pathway, including the primary visual cortex (V1), over the course of retinal degeneration in the RCS rat. However, little is known about how the excitability of the V1 circuit changes during over the course of the gradual loss of visual signal input from the retina. We elucidated the properties of responses to electrical stimulations directly applied to V1 at different stages of vision input loss in the RCS rat in reference to those of the Long-Evans (LE) rat, using in vivo voltage-sensitive dye imaging. The V1 neuronal network of the RCS rat exhibited an excitatory response comparable to the LE rat. The excitatory response was maintained even long after total loss of the visual signal input from the retina. However, the response time-course suggested that the suppressive response was somewhat debilitated in the RCS rat. This is the first experiment demonstrating the long-term effect of retinal degeneration on cortical activities. Our findings provide the physiological fundamentals to enhance the preclinical research of cortical prostheses with the use of the RCS rat.
Collapse
|
7
|
Strategies to improve stimulation efficiency for retinal prostheses. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:3133-3138. [PMID: 28324979 DOI: 10.1109/embc.2016.7591393] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Retinitis Pigmentosa (RP) is a degenerative disease of the retina that leads to vision loss. Retinal prostheses are being developed in order to restore functional vision in patients suffering from RP. We conducted in-vivo experiments in order to identify strategies to efficiently stimulate the retina. We electrically stimulated the retina and measured electrically evoked potentials (EERs) from the superior colliculus of rats. We compared the strength of EERs when voltage-controlled and current-controlled pulses of varying pulse width and charge levels were applied to the retina. In addition to comparing EER strength, we evaluated improvement in power efficiency afforded by a high surface area platinum-iridium material. Voltage-controlled pulses were more efficient than current-controlled pulses when the pulses have a short duration (<; 1 ms) and current-controlled pulses were more efficient than voltage-controlled pulses when the pulse width was greater than 1 ms. The high surface area platinum-iridium stimulation electrode consumed power significantly lower than a standard platinum-iridium electrode.
Collapse
|
8
|
A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness. NATURE MATERIALS 2017; 16:681-689. [PMID: 28250420 PMCID: PMC5446789 DOI: 10.1038/nmat4874] [Citation(s) in RCA: 156] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 01/31/2017] [Indexed: 05/17/2023]
Abstract
The degeneration of photoreceptors in the retina is one of the major causes of adult blindness in humans. Unfortunately, no effective clinical treatments exist for the majority of retinal degenerative disorders. Here we report on the fabrication and functional validation of a fully organic prosthesis for long-term in vivo subretinal implantation in the eye of Royal College of Surgeons rats, a widely recognized model of retinitis pigmentosa. Electrophysiological and behavioural analyses reveal a prosthesis-dependent recovery of light sensitivity and visual acuity that persists up to 6-10 months after surgery. The rescue of the visual function is accompanied by an increase in the basal metabolic activity of the primary visual cortex, as demonstrated by positron emission tomography imaging. Our results highlight the possibility of developing a new generation of fully organic, highly biocompatible and functionally autonomous photovoltaic prostheses for subretinal implants to treat degenerative blindness.
Collapse
|
9
|
Neuron Stimulation Device Integrated with Silicon Nanowire-Based Photodetection Circuit on a Flexible Substrate. SENSORS 2016; 16:s16122035. [PMID: 27916963 PMCID: PMC5191016 DOI: 10.3390/s16122035] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 11/07/2016] [Accepted: 11/25/2016] [Indexed: 11/28/2022]
Abstract
This paper proposes a neural stimulation device integrated with a silicon nanowire (SiNW)-based photodetection circuit for the activation of neurons with light. The proposed device is comprised of a voltage divider and a current driver in which SiNWs are used as photodetector and field-effect transistors; it has the functions of detecting light, generating a stimulation signal in proportion to the light intensity, and transmitting the signal to a micro electrode. To show the applicability of the proposed neural stimulation device as a high-resolution retinal prosthesis system, a high-density neural stimulation device with a unit cell size of 110×110 μm and a resolution of 32×32 was fabricated on a flexible film with a thickness of approximately 50 μm. Its effectiveness as a retinal stimulation device was then evaluated using a unit cell in an in vitro animal experiment involving the retinal tissue of retinal Degeneration 1 (rd1) mice. Experiments wherein stimulation pulses were applied to the retinal tissues successfully demonstrate that the number of spikes in neural response signals increases in proportion to light intensity.
Collapse
|
10
|
Whole-eye electrical stimulation therapy preserves visual function and structure in P23H-1 rats. Exp Eye Res 2016; 149:75-83. [PMID: 27327393 DOI: 10.1016/j.exer.2016.06.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 06/14/2016] [Accepted: 06/16/2016] [Indexed: 11/28/2022]
Abstract
Low-level electrical stimulation to the eye has been shown to be neuroprotective against retinal degeneration in both human and animal subjects, using approaches such as subretinal implants and transcorneal electrical stimulation. In this study, we investigated the benefits of whole-eye electrical stimulation (WES) in a rodent model of retinitis pigmentosa. Transgenic rats with a P23H-1 rhodopsin mutation were treated with 30 min of low-level electrical stimulation (4 μA at 5 Hz; n = 10) or sham stimulation (Sham group; n = 15), twice per week, from 4 to 24 weeks of age. Retinal and visual functions were assessed every 4 weeks using electroretinography and optokinetic tracking, respectively. At the final time point, eyes were enucleated and processed for histology. Separate cohorts were stimulated once for 30 min, and retinal tissue harvested at 1 h and 24 h post-stimulation for real-time PCR detection of growth factors and inflammatory and apoptotic markers. At all time-points after treatment, WES-treated rat eyes exhibited significantly higher spatial frequency thresholds than untreated eyes. Inner retinal function, as measured by ERG oscillatory potentials (OPs), showed significantly improved OP amplitudes at 8 and 12 weeks post-WES compared to Sham eyes. Additionally, while photoreceptor segment and nuclei thicknesses in P23H-1 rats did not change between treatment groups, WES-treated eyes had significantly greater numbers of retinal ganglion cell nuclei than Sham eyes at 20 weeks post-WES. Gene expression levels of brain-derived neurotrophic factor (BDNF), caspase 3, fibroblast growth factor 2 (FGF2), and glutamine synthetase (GS) were significantly higher at 1 h, but not 24 h after WES treatment. Our findings suggest that WES has a beneficial effect on visual function in a rat model of retinal degeneration and that post-receptoral neurons may be particularly responsive to electrical stimulation therapy.
Collapse
|
11
|
Retinal ganglion cells: mechanisms underlying depolarization block and differential responses to high frequency electrical stimulation of ON and OFF cells. J Neural Eng 2016; 13:016017. [DOI: 10.1088/1741-2560/13/1/016017] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
12
|
Integration of Perforated Subretinal Prostheses With Retinal Tissue. Transl Vis Sci Technol 2015; 4:5. [PMID: 26290776 DOI: 10.1167/tvst.4.4.5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2015] [Accepted: 07/03/2015] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To investigate the integration of subretinal implants containing full-depth perforations of various widths with rat and pig retina across weeks of implantation. METHODS In transgenic P23H rhodopsin line 1 (TgP23H-1) rats and wild-type (WT) pigs, we examined four subretinal implant designs: solid inactive polymer arrays (IPA), IPAs with 5- or 10-μm wide perforations, and active bipolar photovoltaic arrays (bPVA) with 5-μm perforations. We surgically placed the implants into the subretinal space using an external approach in rats or a vitreoretinal approach in pigs. Implant placement in the subretinal space was verified with optical coherence tomography and retinal perfusion was characterized with fluorescein angiography. Rats were sacrificed 8 or 16 weeks post-implantation (wpi) and pigs 2, 4, or 8 wpi, and retinas evaluated at the light microscopic level. RESULTS Regardless of implant design, retinas of both species showed normal vasculature. In TgP23H-1 retinas implanted with 10-μm perforated IPAs, inner nuclear layer (INL) cells migrated through the perforations by 8 wpi, resulting in significant INL thinning by 16 wpi. Additionally, these retinas showed greater pseudo-rosette formation and fibrosis compared with retinas with solid or 5-μm perforated IPAs. TgP23H-1 retinas with bPVAs showed similar INL migration to retinas with 5-μm perforated IPAs, with less fibrosis and rosette formation. WT pig retina with perforated IPAs maintained photoreceptors, showed no migration, and less pseudo-rosette formation, but more fibrosis compared with implanted TgP23H-1 rat retinas. CONCLUSIONS In retinas with photoreceptor degeneration, solid implants, or those with 5-μm perforations lead to the best biocompatibility.
Collapse
|
13
|
Functional changes in Tg P23H-1 rat retinal responses: differences between ON and OFF pathway transmission to the superior colliculus. J Neurophysiol 2015; 114:2368-75. [PMID: 26245318 DOI: 10.1152/jn.00600.2015] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Accepted: 08/04/2015] [Indexed: 01/12/2023] Open
Abstract
The morphological consequences of retinal photoreceptor degeneration are well documented. Much less is known about changes in visual function during degeneration and whether central visual structures directly reflect changes in retinal ganglion cell (RGC) function. To address this, we compared changes in visual function of RGCs and cells in the superior colliculus (SC) in transgenic (Tg) P23H-1 rats, a model of retinitis pigmentosa (RP), and wild-type (WT) rats at postnatal days 35-50 (P35-50) and P300. RGCs were classified on the basis of their responses to light: onset (ON), offset (OFF), or both (ON-OFF). The distribution of ON, OFF, and ON-OFF RGCs is similar between WT and P35 Tg P23H-1 rats. By P300, many Tg P23H-1 RGCs are nonresponsive (NR). At this age, there is a sharp decline in ON and ON-OFF RGCs, and the majority that remain are OFF RGCs. Spontaneous rhythmic activity was observed in many RGCs at P300, but only in OFF or NR RGCs. In the SC, WT and P50 Tg P23H-1 responses are similar. At P300, Tg P23H-1 ON SC responses declined but OFF responses increased. We examined postsynaptic glutamate receptor expression located on the bipolar cells (BC), where the ON and OFF pathways arise. At P150, metabotropic glutamate receptor 6 (mGluR6) expression is lower than in WT, consistent with a decrease in ON RGC responses. GluR4 expression, an ionotropic glutamate receptor associated with OFF BCs, appears similar to that in WT. The loss of ON responses in Tg P23H-1 RGCs and in the SC is conserved and related to reduced mGluR6 signaling.
Collapse
|
14
|
Properties of electrically evoked potentials activated by optic nerve stimulation with penetrating electrodes of different modes in rabbits. Graefes Arch Clin Exp Ophthalmol 2015; 253:2171-80. [DOI: 10.1007/s00417-015-3121-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 07/16/2015] [Accepted: 07/18/2015] [Indexed: 10/23/2022] Open
|
15
|
Visual prostheses: the enabling technology to give sight to the blind. J Ophthalmic Vis Res 2015; 9:494-505. [PMID: 25709777 PMCID: PMC4329712 DOI: 10.4103/2008-322x.150830] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2013] [Accepted: 03/02/2014] [Indexed: 11/08/2022] Open
Abstract
Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices.
Collapse
|
16
|
Abstract
OBJECTIVE In clinical trials, retinitis pigmentosa patients implanted with a retinal prosthetic device show enhanced spatial vision, including the ability to read large text and navigate. New prosthetics aim to increase spatial resolution by decreasing pixel/electrode size and limiting current spread. To examine spatial resolution of a new prosthetic design, we characterized and compared two photovoltaic array (PVA) designs and their interaction with the retina after subretinal implantation in transgenic S334ter line 3 rats (Tg S334ter-3). APPROACH PVAs were implanted subretinally at two stages of degeneration and assessed in vivo using extracellular recordings in the superior colliculus (SC). Several aspects of this interaction were evaluated by varying duration, irradiance and position of a near infrared laser focused on the PVA. These characteristics included: activation threshold, response linearity, SC signal topography and spatial localization. The major design difference between the two PVA designs is the inclusion of local current returns in the newer design. MAIN RESULTS When tested in vivo, PVA-evoked response thresholds were independent of pixel/electrode size, but differ between the new and old PVA designs. Response thresholds were independent of implantation age and duration (⩽7.5 months). For both prosthesis designs, threshold intensities were within established safety limits. PVA-evoked responses require inner retina synaptic transmission and do not directly activate retinal ganglion cells. The new PVA design evokes local retinal activation, which is not found with the older PVA design that lacks local current returns. SIGNIFICANCE Our study provides in vivo evidence that prosthetics make functional contacts with the inner nuclear layer at several stages of degeneration. The new PVA design enhances local activation within the retina and SC. Together these results predict that the new design can potentially harness the inherent processing within the retina and is likely to produce higher spatial resolution in patients.
Collapse
|
17
|
Abstract
Light activation of neurons is a growing field with applications ranging from basic investigation of neuronal systems to the development of new therapeutic methods such as artificial retina. Many recent studies currently explore novel methods for optical stimulation with temporal and spatial precision. Novel materials in particular provide an opportunity to enhance contemporary approaches. Here we review recent advances towards light directed interfaces for neuronal stimulation, focusing on state-of-the-art nanoengineered devices. In particular, we highlight challenges and prospects towards improved retinal prostheses.
Collapse
|
18
|
Neuroprotective Effects of Low Level Electrical Stimulation Therapy on Retinal Degeneration. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2014; 801:845-51. [DOI: 10.1007/978-1-4614-3209-8_106] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
19
|
Abstract
PURPOSE OF REVIEW Outer retinal degenerations such as retinitis pigmentosa can cause profound vision loss. Various treatment strategies are being pursued to potentially restore functional vision in these patients. RECENT FINDINGS Advances in retinal prostheses have restored some vision in patients previously blind from retinitis pigmentosa. Optogenetics is another area that shows promise for restoration of vision. Transcorneal electrostimulation shows some efficacy to treat these patients as well. SUMMARY We review recent advances in optogenetics, visual prosthesis and electrostimulation to treat outer retinal degenerations.
Collapse
|
20
|
Alterations of sodium and potassium channels of RGCs in RCS rat with the development of retinal degeneration. J Mol Neurosci 2013; 51:976-85. [PMID: 23934450 DOI: 10.1007/s12031-013-0082-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2013] [Accepted: 07/22/2013] [Indexed: 11/28/2022]
Abstract
All know that retinitis pigmentosa (RP) is a group of hereditary retinal degenerative diseases characterized by progressive dysfunction of photoreceptors and associated with progressive cells loss; nevertheless, little is known about how rods and cones loss affects the surviving inner retinal neurons and networks. Retinal ganglion cells (RGCs) process and convey visual information from retina to visual centers in the brain. The healthy various ion channels determine the normal reception and projection of visual signals from RGCs. Previous work on the Royal College of Surgeons (RCS) rat, as a kind of classical RP animal model, indicated that, at late stages of retinal degeneration in RCS rat, RGCs were also morphologically and functionally affected. Here, retrograde labeling for RGCs with Fluorogold was performed to investigate the distribution, density, and morphological changes of RGCs during retinal degeneration. Then, patch clamp recording, western blot, and immunofluorescence staining were performed to study the channels of sodium and potassium properties of RGCs, so as to explore the molecular and proteinic basis for understanding the alterations of RGCs membrane properties and firing functions. We found that the resting membrane potential, input resistance, and capacitance of RGCs changed significantly at the late stage of retinal degeneration. Action potential could not be evoked in a part of RGCs. Inward sodium current and outward potassium current recording showed that sodium current was impaired severely but only slightly in potassium current. Expressions of sodium channel protein were impaired dramatically at the late stage of retinal degeneration. The results suggested that the density of RGCs decreased, process ramification impaired, and sodium ion channel proteins destructed, which led to the impairment of electrophysiological functions of RGCs and eventually resulted in the loss of visual function.
Collapse
|
21
|
Electronic restoration of vision in those with photoreceptor degenerations. Clin Exp Optom 2012; 95:473-83. [PMID: 22823954 DOI: 10.1111/j.1444-0938.2012.00783.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2011] [Revised: 06/06/2012] [Accepted: 06/11/2012] [Indexed: 11/27/2022] Open
Abstract
Complete loss of vision is one of the most feared sequelae of retinal disease. Currently, there are few if any treatment options available to patients that may slow or prevent blindness in diseases caused by photoreceptor loss, such as retinitis pigmentosa and age-related macular degeneration. Electronic restoration of vision has emerged over recent years as a safe and viable option for those who have lost substantial numbers of photoreceptors and who are severely vision impaired. Indeed, there has been a dramatic increase in our understanding of what is required to restore vision using an electronic retinal prosthesis. Recent reports show that for some patients, restoration of vision to the point of reading large letters is possible. In this review, we examine the types of implants currently under investigation and the results these devices have achieved clinically. We then consider a range of engineering and biological factors that may need to be considered to improve the visual performance of newer-generation devices. With added research, it is hoped that the level of vision achieved with newer generation devices will steadily improve, resulting in enhanced quality of life for those with severe vision impairment.
Collapse
|
22
|
Abstract
The objective of this work is to develop and test a photovoltaic retinal prosthesis for restoring sight to patients blinded by degenerative retinal diseases. A silicon photodiode array for subretinal stimulation has been fabricated by a silicon-integrated-circuit/MEMS process. Each pixel in the two-dimensional array contains three series-connected photodiodes, which photovoltaically convert pulsed near-infrared light into bi-phasic current to stimulate nearby retinal neurons without wired power connections. The device thickness is chosen to be 30 µm to absorb a significant portion of light while still being thin enough for subretinal implantation. Active and return electrodes confine current near each pixel and are sputter coated with iridium oxide to enhance charge injection levels and provide a stable neural interface. Pixels are separated by 5 µm wide trenches to electrically isolate them and to allow nutrient diffusion through the device. Three sizes of pixels (280, 140 and 70 µm) with active electrodes of 80, 40 and 20 µm diameter were fabricated. The turn-on voltages of the one-diode, two-series-connected diode and three-series-connected diode structures are approximately 0.6, 1.2 and 1.8 V, respectively. The measured photo-responsivity per diode at 880 nm wavelength is ∼0.36 A W(-1), at zero voltage bias and scales with the exposed silicon area. For all three pixel sizes, the reverse-bias dark current is sufficiently low (<100 pA) for our application. Pixels of all three sizes reliably elicit retinal responses at safe near-infrared light irradiances, with good acceptance of the photodiode array in the subretinal space. The fabricated device delivers efficient retinal stimulation at safe near-infrared light irradiances without any wired power connections, which greatly simplifies the implantation procedure. Presence of the return electrodes in each pixel helps to localize the current, and thereby improves resolution.
Collapse
|
23
|
Development of the boston retinal prosthesis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:3135-8. [PMID: 22255004 DOI: 10.1109/iembs.2011.6090855] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A small, hermetic, wirelessly-controlled retinal prosthesis was developed for pre-clinical studies in Yucatan mini-pigs. The device was implanted on the outside of the eye in the orbit, and it received both power and data wirelessly from external sources. The prosthesis drove a sub-retinal thin-film array of sputtered iridium oxide stimulating electrodes. The implanted device included a hermetic titanium case containing the 16-channel stimulator chip and discrete circuit components. Feedthroughs in the hermetic case connected the chip to secondary power- and data-receiving coils, which coupled to corresponding external power and data coils driven by a power amplifier. Power was delivered by a 500 KHz carrier, and data were delivered by frequency shift keying. Stimulation pulse strength, duration and frequency were programmed wirelessly from an external computer system. Through an 'outbound' telemetry channel, electrode impedances were monitored by an on-board analog to digital converter that sampled the output voltage waveforms. The final assembly was tested in vitro in physiological saline and in vivo in two mini-pigs for up to three months by measuring stimulus artifacts generated by the implant's current drivers.
Collapse
|
24
|
Photovoltaic Retinal Prosthesis with High Pixel Density. NATURE PHOTONICS 2012; 6:391-397. [PMID: 23049619 PMCID: PMC3462820 DOI: 10.1038/nphoton.2012.104] [Citation(s) in RCA: 239] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Accepted: 04/04/2012] [Indexed: 05/21/2023]
Abstract
Retinal degenerative diseases lead to blindness due to loss of the "image capturing" photoreceptors, while neurons in the "image processing" inner retinal layers are relatively well preserved. Electronic retinal prostheses seek to restore sight by electrically stimulating surviving neurons. Most implants are powered through inductive coils, requiring complex surgical methods to implant the coil-decoder-cable-array systems, which deliver energy to stimulating electrodes via intraocular cables. We present a photovoltaic subretinal prosthesis, in which silicon photodiodes in each pixel receive power and data directly through pulsed near-infrared illumination and electrically stimulate neurons. Stimulation was produced in normal and degenerate rat retinas, with pulse durations from 0.5 to 4 ms, and threshold peak irradiances from 0.2 to 10 mW/mm(2), two orders of magnitude below the ocular safety limit. Neural responses were elicited by illuminating a single 70 μm bipolar pixel, demonstrating the possibility of a fully-integrated photovoltaic retinal prosthesis with high pixel density.
Collapse
|
25
|
Overview of the boston retinal prosthesis: challenges and opportunities to restore useful vision to the blind. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:7492-5. [PMID: 22256071 DOI: 10.1109/iembs.2011.6093610] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A small, hermetic, wirelessly-controlled retinal prosthesis was developed for pre-clinical studies in Yucatan mini-pigs. The device was implanted on the outside of the eye in the orbit, and it received both power and data wirelessly from external sources. The prosthesis drove a sub-retinal thin-film array of sputtered iridium oxide stimulating electrodes. The implanted device included a hermetic titanium case containing the 16-channel stimulator chip and discrete circuit components. Feedthroughs in the hermetic case connected the chip to secondary power- and data-receiving coils, which coupled to corresponding external power and data coils driven by a power amplifier. Power was delivered by a 500 KHz carrier, and data were delivered by frequency shift keying. Stimulation pulse strength, duration and frequency were programmed wirelessly from an external computer system. Through an 'outbound' telemetry channel, electrode impedances were monitored by an on-board analog to digital converter that sampled the output voltage waveforms. The final assembly was tested in vitro in physiological saline and in vivo in two mini-pigs for up to three months by measuring stimulus artifacts generated by the implant's current drivers.
Collapse
|
26
|
Neuroprotective dose response in RCS rats implanted with microphotodiode arrays. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2012; 723:115-20. [PMID: 22183323 DOI: 10.1007/978-1-4614-0631-0_16] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
27
|
|
28
|
Non-viral gene therapy for GDNF production in RCS rat: the crucial role of the plasmid dose. Gene Ther 2011; 19:886-98. [DOI: 10.1038/gt.2011.154] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
29
|
Communication and Control System for a 15-Channel Hermetic Retinal Prosthesis. Biomed Signal Process Control 2011; 6:356-363. [PMID: 21927618 DOI: 10.1016/j.bspc.2011.05.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
A small, hermetic, wirelessy-controlled retinal prosthesis has been developed for pre-clinical studies in Yucatan minipigs. The device was attached conformally to the outside of the eye in the socket and received both power and data wirelessly from external sources. Based on the received image data, the prosthesis drove a subretinal thin-film polyimide array of sputtered iridium oxide stimulating electrodes. The implanted device included a hermetic titanium case containing a 15-channel stimulator and receiver chip and discrete circuit components. Feedthroughs in the hermetic case connected the chip to secondary power- and data-receiving coils, which coupled to corresponding external power and data coils driven by power amplifiers. Power was delivered by a 125 KHz carrier, and data were delivered by amplitude shift keying of a 15.5 MHz carrier at 100 Kbps. Stimulation pulse strength, duration and frequency were programmed wirelessly from an external computer system. The final assembly was tested in vitro in physiological saline and in vivo in two minipigs for up to five and a half months by measuring stimulus artifacts generated by the implant's current drivers.
Collapse
|
30
|
Abstract
Photodiode circuits show promise for the development of high-resolution retinal prostheses. While several of these systems have been constructed and some even implanted in humans, existing descriptions of the complex optoelectronic interaction between light, photodiode, and the electrode/electrolyte load are limited. This study examines this interaction in depth with theoretical calculations and experimental measurements. Actively biased photoconductive and passive photovoltaic circuits are investigated, with the photovoltaic circuits consisting of one or more diodes connected in series, and the photoconductive circuits consisting of a single diode in series with a pulsed bias voltage. Circuit behavior and charge injection levels were markedly different for platinum and sputtered iridium-oxide film (SIROF) electrodes. Photovoltaic circuits were able to deliver 0.038 mC/cm(2) (0.75 nC/phase) per photodiode with 50- μm platinum electrodes, and 0.54-mC/cm(2) (11 nC/phase) per photodiode with 50-μ m SIROF electrodes driven with 0.5-ms pulses of light at 25 Hz. The same pulses applied to photoconductive circuits with the same electrodes were able to deliver charge injections as high as 0.38 and 7.6 mC/cm(2) (7.5 and 150 nC/phase), respectively. We demonstrate photovoltaic stimulation of rabbit retina in-vitro, with 0.5-ms pulses of 905-nm light using peak irradiance of 1 mW/mm(2). Based on the experimental data, we derive electrochemical and optical safety limits for pixel density and charge injection in various circuits. While photoconductive circuits offer smaller pixels, photovoltaic systems do not require an external bias voltage. Both classes of circuits show promise for the development of high-resolution optoelectronic retinal prostheses.
Collapse
|
31
|
Abstract
A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device.
Collapse
|
32
|
Subretinal electronic chips allow blind patients to read letters and combine them to words. Proc Biol Sci 2011; 278:1489-97. [PMID: 21047851 PMCID: PMC3081743 DOI: 10.1098/rspb.2010.1747] [Citation(s) in RCA: 625] [Impact Index Per Article: 48.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2010] [Accepted: 10/13/2010] [Indexed: 11/12/2022] Open
Abstract
A light-sensitive, externally powered microchip was surgically implanted subretinally near the macular region of volunteers blind from hereditary retinal dystrophy. The implant contains an array of 1500 active microphotodiodes ('chip'), each with its own amplifier and local stimulation electrode. At the implant's tip, another array of 16 wire-connected electrodes allows light-independent direct stimulation and testing of the neuron-electrode interface. Visual scenes are projected naturally through the eye's lens onto the chip under the transparent retina. The chip generates a corresponding pattern of 38 × 40 pixels, each releasing light-intensity-dependent electric stimulation pulses. Subsequently, three previously blind persons could locate bright objects on a dark table, two of whom could discern grating patterns. One of these patients was able to correctly describe and name objects like a fork or knife on a table, geometric patterns, different kinds of fruit and discern shades of grey with only 15 per cent contrast. Without a training period, the regained visual functions enabled him to localize and approach persons in a room freely and to read large letters as complete words after several years of blindness. These results demonstrate for the first time that subretinal micro-electrode arrays with 1500 photodiodes can create detailed meaningful visual perception in previously blind individuals.
Collapse
|
33
|
Both electrical stimulation thresholds and SMI-32-immunoreactive retinal ganglion cell density correlate with age in S334ter line 3 rat retina. J Neurophysiol 2011; 105:2687-97. [PMID: 21411561 DOI: 10.1152/jn.00619.2010] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Electrical stimulation threshold and retinal ganglion cell density were measured in a rat model of retinal degeneration. We performed in vivo electrophysiology and morphometric analysis on normal and S334ter line 3 (RD) rats (ages 84-782 days). We stimulated the retina in anesthetized animals and recorded evoked responses in the superior colliculus. Current pulses were delivered with a platinum-iridium (Pt-Ir) electrode of 75-μm diameter positioned on the epiretinal surface. In the same animals used for electrophysiology, SMI-32 immunolabeling of the retina enabled ganglion cell counting. An increase in threshold currents positively correlated with age of RD rats. SMI-32-labeled retinal ganglion cell density negatively correlated with age of RD rats. ANOVA shows that RD postnatal day (P)100 and P300 rats have threshold and density similar to normal rats, but RD P500 and P700 rats have threshold and density statistically different from normal rats (P < 0.05). Threshold charge densities were within the safety limits of Pt for all groups and pulse configurations, except at RD P600 and RD P700, where pulses were only safe up to 1- and 0.2-ms duration, respectively. Preservation of ganglion cells may enhance the efficiency and safety of electronic retinal implants.
Collapse
|
34
|
Realization of a 15-channel, hermetically-encased wireless subretinal prosthesis for the blind. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2009:200-3. [PMID: 19964209 DOI: 10.1109/iembs.2009.5333619] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A miniaturized, hermetically-encased, wirelessly-operated retinal prosthesis has been developed for implantation and pre-clinical studies in Yucatan mini-pig animal models. The prosthesis conforms to the eye and drives a microfabricated polyimide stimulating electrode array with sputtered iridium oxide electrodes. This array is implanted in the subretinal space using a specially-designed ab externo surgical technique that affixes the bulk of the prosthesis to the surface of the sclera. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete power supply components. Feedthroughs from the case connect to secondary power- and data-receiving coils. In addition, long-term in vitro pulse testing was performed on the electrodes to ensure their stability for the long lifetime of the hermetic case. The final assembly was tested in vitro to verify wireless operation of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation pulse strength, duration and frequency were programmed wirelessly using a custom graphical user interface. Operation of the retinal implant has been verified in vivo in one pig for more than three months by measuring stimulus artifacts on the eye surface using a contact lens electrode.
Collapse
|
35
|
Morphological alterations in retinal neurons in the S334ter-line3 transgenic rat. Cell Tissue Res 2010; 339:481-91. [PMID: 20127257 DOI: 10.1007/s00441-009-0916-5] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2009] [Accepted: 12/11/2009] [Indexed: 10/19/2022]
Abstract
The S334ter-line-3 rat is a transgenic model of retinal degeneration developed to express a rhodopsin mutation similar to that found in human retinitis pigmentosa (RP) patients. Previous studies have focused on physiological changes in retinal cells and higher centers of the visual system with this model of retinal degeneration. However, little is known about the morphological changes in retinal cells during the development of the S334ter-line-3 rat. In order to understand and aid vision-rescue strategies, our aim has been to describe the retinal degeneration pattern in this model. We focus on changes in the morphologies of horizontal, bipolar, and amacrine cells in developing S334ter-line-3 rat retinas. Degeneration of photoreceptors begins in the central retina and progresses toward the periphery. In retinas at post-natal day 15 (P15), horizontal and rod bipolar cells show normal morphology. However, at P21, horizontal and rod bipolar cells exhibit abnormal processes at the outer plexiform layer, whereas the outer nuclear layer is significantly thinner. A glial reaction occurs concomitantly. In contrast, modifications in cone-bipolar and amacrine cells are much slower and do not occur until P90 and P180, respectively. The density of horizontal and rod-bipolar cells significantly drops after P60. Overall, the S334ter-line-3 model exhibits the hallmarks of cellular remodeling caused by photoreceptor degeneration. Its moderately fast time course makes the S334ter-line-3 a good model for studying vision-rescue strategies.
Collapse
|
36
|
Late histological and functional changes in the P23H rat retina after photoreceptor loss. Neurobiol Dis 2010; 38:47-58. [PMID: 20060471 DOI: 10.1016/j.nbd.2009.12.025] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2009] [Revised: 12/09/2009] [Accepted: 12/26/2009] [Indexed: 10/20/2022] Open
Abstract
Several strategies have been proposed to restore useful vision following photoreceptor degeneration. However, a very few studies have investigated late anatomical changes and functional state of residual retinal neurons after complete photoreceptor loss. We investigated the progressive degeneration of retinal ganglion cells (RGCs) in P23H rats. The RGC multielectrode array recordings indicated lower firing rates, disappearance of broad-scale, and maintenance of short-scale pairwise correlations. Up to 11% of RGCs displayed repetitive and often correlated spike discharges, reminiscent of developmental rhythmic activity, which could be reversibly suppressed by blockade of the AMPA/kainite glutamate receptors. RGCs in P23H rats remain sensitive to local electrical stimulation, generating short-latency responses as in the normal retina. These results provide evidence that, despite the demonstrated RGC degeneration, remaining active RGCs maintain their basic physiological and network properties with some emerging functional changes such as the spontaneous rhythmic activity in late stages of the degenerative disease.
Collapse
|
37
|
Stimulation of the Retinal Network in Bionic Vision Devices: From Multi-Electrode Arrays to Pixelated Vision. ACTA ACUST UNITED AC 2010. [DOI: 10.1007/978-3-642-17537-4_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2023]
|
38
|
|
39
|
Development and implantation of a minimally invasive wireless subretinal neurostimulator. IEEE Trans Biomed Eng 2009; 56:2502-11. [PMID: 19403357 DOI: 10.1109/tbme.2009.2021401] [Citation(s) in RCA: 120] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A wirelessly operated, minimally invasive retinal prosthesis was developed for preclinical chronic implantation studies in Yucatan minipig models. The implant conforms to the outer wall of the eye and drives a microfabricated polyimide stimulating electrode array with sputtered iridium oxide electrodes. This array is implanted in the subretinal space using a specially designed ab externo surgical technique that fixes the bulk of the prosthesis to the outer surface of the sclera. The implanted device is fabricated on a host polyimide flexible circuit. It consists of a 15-channel stimulator chip, secondary power and data receiving coils, and discrete power supply components. The completed device is encapsulated in poly(dimethylsiloxane) except for the reference/counter electrode and the thin electrode array. In vitro testing was performed to verify the performance of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation patterns as well as pulse strength, duration, and frequency were programmed wirelessly using custom software and a graphical user interface. Wireless operation of the retinal implant has been verified both in vitro and in vivo in three pigs for more than seven months, the latter by measuring stimulus artifacts on the eye surface using contact lens electrodes.
Collapse
|
40
|
Retinal ganglion cells survive and maintain normal dendritic morphology in a mouse model of inherited photoreceptor degeneration. J Neurosci 2009; 28:14282-92. [PMID: 19109509 DOI: 10.1523/jneurosci.4968-08.2008] [Citation(s) in RCA: 196] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Retinitis pigmentosa (RP), a family of inherited disorders characterized by progressive photoreceptor death, is a leading cause of blindness with no available cure. Despite the genetic heterogeneity underlying the disease, recent data on animal models show that the degeneration of photoreceptors triggers stereotyped remodeling among their postsynaptic partners. In particular, bipolar and horizontal cells might undergo dendritic atrophy and secondary death. The aim of this study was to investigate whether or not concomitant changes also occur in retinal ganglion cells (RGCs), the only retinal projection neurons to the brain and the proposed substrate for various therapeutic approaches for RP. We assessed the retention of morphology, overall architecture, and survival of RGCs in a mouse model of RP at various stages of the disease. To study the morphology of single RGCs, we generated a new mouse line by crossing Thy1-GFP-M mice (Feng et al., 2000), which express GFP (green fluorescent protein) in a small number of heterogeneous RGCs types, and rd10 mutants, a model of autosomal recessive RP, which exhibit a typical rod-cone degeneration (Chang et al., 2002). We show remarkable preservation of RGC structure, survival, and projections to higher visual centers in the time span from 3 to 9 months of life, well beyond the death of photoreceptors. Thus, unlike second-order neurons, RGCs appear as a considerably stable population of cells, potentially constituting a favorable substrate for restoring vision in RP individuals by means of electronic prostheses or direct expression of photosensitive proteins.
Collapse
|
41
|
Retinal expression of Fgf2 in RCS rats with subretinal microphotodiode array. Invest Ophthalmol Vis Sci 2009; 50:4523-30. [PMID: 19264883 DOI: 10.1167/iovs.08-2072] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To test the hypothesis that subretinal electrical stimulation from a microphotodiode array (MPA) exerts a neuroprotective effect in Royal College of Surgeons (RCS) rats through the induction of growth factors. METHODS At postnatal day 21, RCS rats were divided into four groups in which one eye per rat received treatment: (A) active MPA, (M) minimally active MPA, (S) sham surgery, or (C) no surgery and the opposite eye was unoperated. Dark- and light-adapted ERGs were recorded 1 week after surgery. A second set of A-, M-, and C-treated RCS rats had weekly ERG recordings for 4 weeks. Real-time RT-PCR was used to measure relative expression of mRNAs (Bdnf, Fgf2, Fgf1, Cntf, Gdnf, and Igf1) in retina samples collected 2 days after the final ERG. RESULTS One week after surgery, there was a slight difference in dark-adapted ERG b-wave at the brightest flash intensity. Mean retinal Fgf2 expression in the treated eye relative to the opposite eye was greater for the A group (4.67 +/- 0.72) than for the M group (2.80 +/- 0.45; P = 0.0501), S group (2.03 +/- 0.45; P < 0.01), and C group (1.30 +/- 0.22; P < 0.001). No significant change was detected for Bdnf, Cntf, Fgf1, Gdnf, and Igf1. Four weeks after surgery, the A group had significantly larger dark- and light-adapted ERG b-waves than for the M and C groups (P < 0.01). Simultaneously, mean relative Fgf2 expression was again greater for the A group (3.28 +/- 0.61) than for the M (1.28 +/- 0.32; P < 0.05) and C (1.05 +/- 0.04; P < 0.05) groups. CONCLUSIONS The results show subretinal implantation of an MPA induces selective expression of Fgf2 above that expected from a retina-piercing injury. Preservation of ERG b-wave amplitude 4 weeks after implantation is accompanied by elevated Fgf2 expression. These results suggest that Fgf2 may play a role in the neuroprotection provided by subretinal electrical stimulation.
Collapse
|
42
|
Neuroprotective effect of transretinal electrical stimulation on neurons in the inner nuclear layer of the degenerated retina. Brain Res Bull 2009; 79:15-25. [PMID: 19150490 DOI: 10.1016/j.brainresbull.2008.12.013] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2008] [Revised: 10/03/2008] [Accepted: 12/18/2008] [Indexed: 11/17/2022]
Abstract
Electrical stimulation has been shown to have neuroprotective effects on ganglion cells and photoreceptors in axotomized and dystrophic retinas from Royal College of Surgeons (RCS) rats. This study determined whether electrical stimulation also has a neuroprotective effect on cells in the inner nuclear layer (INL) of retinas. We cultivated retinas from adult RCS rats on microelectrode arrays and stimulated them continuously with 20 Hz for up to 5 days. Afterwards, we subjected them to quantitative immunohistochemical analysis. Using TUNEL assay we found that transretinal electrical stimulation (TRES) with charge densities within the range of 100-500 microC/cm2 reduced apoptosis of neurons in the INL of degenerated retinas from RCS -/- rats by 20% after 1 day of continuous stimulation. Antibody staining (OX-42, ED1) revealed a reduced activation of migroglial cells in RCS -/- and congenic control (RCS +/+) rat retinas by up to 50% after 1 day of stimulation. The effect of electrical stimulation on apoptosis and reduced activation of microglial cells was closely correlated with the strength and duration of the stimulation. The neuroprotective effect of TRES on neuronal cells in the INL of degenerated RCS rat retinas supports the idea that electrical stimulation may be a therapeutic option to delay the progression of retinal degeneration in patients suffering from retinitis pigmentosa.
Collapse
|
43
|
|
44
|
Intraorbital optic nerve stimulation with penetrating electrodes: in vivo electrophysiology study in rabbits. Graefes Arch Clin Exp Ophthalmol 2008; 247:349-61. [DOI: 10.1007/s00417-008-0977-2] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2008] [Revised: 08/26/2008] [Accepted: 10/06/2008] [Indexed: 11/28/2022] Open
|
45
|
Effect of shape and coating of a subretinal prosthesis on its integration with the retina. Exp Eye Res 2008; 88:22-9. [PMID: 18955050 DOI: 10.1016/j.exer.2008.09.018] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2008] [Revised: 09/09/2008] [Accepted: 09/13/2008] [Indexed: 10/21/2022]
Abstract
Retinal stimulation with high spatial resolution requires close proximity of electrodes to target cells. This study examines the effects of material coatings and 3-dimensional geometries of subretinal prostheses on their integration with the retina. A trans-scleral implantation technique was developed to place microfabricated structures in the subretinal space of RCS rats. The effect of three coatings (silicon oxide, iridium oxide and parylene) and three geometries (flat, pillars and chambers) on the retinal integration was compared using passive implants. Retinal morphology was evaluated histologically 6 weeks after implantation. For 3-dimensional implants the retinal cell phenotype was also evaluated using Computational Molecular Phenotyping. Flat implants coated with parylene and iridium oxide were generally well tolerated in the subretinal space, inducing only a mild gliotic response. However, silicon-oxide coatings induced the formation of a significant fibrotic seal around the implants. Glial proliferation was observed at the base of the pillar electrode arrays and inside the chambers. The non-traumatic penetration of pillar tips into the retina provided uniform and stable proximity to the inner nuclear layer. Retinal cells migrated into chambers with apertures larger than 10 mum. Both pillars and chambers achieved better proximity to the inner retinal cells than flat implants. However, isolation of retinal cells inside the chamber arrays is likely to affect their long-term viability. Pillars demonstrated minimal alteration of the inner retinal architecture, and thus appear to be the most promising approach for maintaining close proximity between the retinal prosthetic electrodes and target neurons.
Collapse
|
46
|
A review of in vivo animal studies in retinal prosthesis research. Graefes Arch Clin Exp Ophthalmol 2008; 246:1505-17. [PMID: 18709385 DOI: 10.1007/s00417-008-0891-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2008] [Revised: 06/12/2008] [Accepted: 06/16/2008] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND The development of a functional retinal prosthesis for acquired blindness is a great challenge. Rapid progress in the field over the last 15 years would not have been possible without extensive animal experimentation pertaining to device design and fabrication, biocompatibility, stimulation parameters and functional responses. This paper presents an overview of in vivo animal research related to retinal prosthetics, and aims to summarize the relevant studies. METHODS A Pubmed search of the English language literature was performed. The key search terms were: retinal implant, retinal prosthesis, artificial vision, rat, rabbit, cat, dog, sheep, pig, minipig. In addition a manual search was performed based on references quoted in the articles retrieved through Pubmed. RESULTS We identified 50 articles relevant to in vivo animal experimentation directly related to the development of a retinal implant. The highest number of publications related to the cat (n = 18). CONCLUSION The contribution of animal models to the development of retinal prosthetic devices has been enormous, and has led to human feasibility studies. Grey areas remain regarding long-term tissue-implant interactions, biomaterials, prosthesis design and neural adaptation. Animals will continue to play a key role in this rapidly evolving field.
Collapse
|
47
|
|
48
|
|
49
|
Abstract
The design of high-resolution retinal prostheses presents many unique engineering and biological challenges. Ever smaller electrodes must inject enough charge to stimulate nerve cells, within electrochemically safe voltage limits. Stimulation sites should be placed within an electrode diameter from the target cells to prevent 'blurring' and minimize current. Signals must be delivered wirelessly from an external source to a large number of electrodes, and visual information should, ideally, maintain its natural link to eye movements. Finally, a good system must have a wide range of stimulation currents, external control of image processing and the option of either anodic-first or cathodic-first pulses. This paper discusses these challenges and presents solutions to them for a system based on a photodiode array implant. Video frames are processed and imaged onto the retinal implant by a head-mounted near-to-eye projection system operating at near-infrared wavelengths. Photodiodes convert light into pulsed electric current, with charge injection maximized by applying a common biphasic bias waveform. The resulting prosthesis will provide stimulation with a frame rate of up to 50 Hz in a central 10 degrees visual field, with a full 30 degrees field accessible via eye movements. Pixel sizes are scalable from 100 to 25 microm, corresponding to 640-10,000 pixels on an implant 3 mm in diameter.
Collapse
|