1
|
von Kroge S, Schmidt C, Butscheidt S, Ohlmeier M, Amling M, Beil FT, Gehrke T, Püschel K, Hahn M, Rolvien T. Allografts promote skeletal regeneration of periprosthetic femoral bone loss. J Orthop Translat 2025; 52:182-191. [PMID: 40330274 PMCID: PMC12053977 DOI: 10.1016/j.jot.2025.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2024] [Revised: 03/19/2025] [Accepted: 04/12/2025] [Indexed: 05/08/2025] Open
Abstract
Background Periprosthetic bone loss is a common clinical problem in hip arthroplasty that must be addressed during revision surgery to achieve adequate implant stability. Although bone allografts represent the clinical standard among substitute materials used, evidence of their regenerative potential at the microstructural, cellular, and compositional level is lacking. Methods A multiscale imaging approach comprising contact radiography, undecalcified histology, scanning electron microscopy, and nanoindentation was employed on human femoral explants obtained postmortem many years after allograft use during revision surgery. Results The degree of skeletal regeneration through allograft incorporation between host bone and allograft bone was highly dependent on the defect depth (R2 = 0.94, p < 0.001), while no association between the allograft time in situ and incorporation (R2 = 0.06, p = 0.61) was apparent. The host bone-allograft interface showed a high overlap of 4.0 ± 2.9 mm and was characterized by active bone remodelling, as indicated by osteoid accumulation, high abundance of bone cells and vasculature. While bone cement generally limited the incorporation process, the osteocytic canalicular system of the host bone reached the allograft interface to guide bone remodelling. Conclusion This is the first multiscale, histomorphometry-based evaluation of bone allografts used in revision hip arthroplasty for femoral bone loss in humans, demonstrating that they adequately facilitate skeletal regeneration through osteoconduction and subsequent remodelling. The translational potential of this article This study identified the mechanisms and determinants of femoral defect regeneration through allografts on the basis of a unique sample collection. While our results support their favourable clinical outcomes, the scientific basis for incomplete incorporation is also demonstrated.
Collapse
Affiliation(s)
- Simon von Kroge
- Institute of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 59, 22529, Hamburg, Germany
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Constantin Schmidt
- Institute of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 59, 22529, Hamburg, Germany
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Sebastian Butscheidt
- Institute of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 59, 22529, Hamburg, Germany
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Malte Ohlmeier
- Department of Joint Surgery, Helios ENDO-Klinik, Holstenstr. 2, 22767, Hamburg, Germany
| | - Michael Amling
- Institute of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 59, 22529, Hamburg, Germany
| | - Frank Timo Beil
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Joint Surgery, Helios ENDO-Klinik, Holstenstr. 2, 22767, Hamburg, Germany
| | - Klaus Püschel
- Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Michael Hahn
- Institute of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 59, 22529, Hamburg, Germany
| | - Tim Rolvien
- Institute of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 59, 22529, Hamburg, Germany
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| |
Collapse
|
2
|
Cheng H, Chen J, Wang Y, Zhang Y, Qin T, Sun H, Si W, Sun N, Sun Y, Xiong L, Deng Z, Lu L, Gao P, Liu J. Sr-doped surfaces with 2D black phosphorus nanosheets for enhanced photothermal antibacterial activity and zirconia implant osseointegration. Regen Biomater 2025; 12:rbaf033. [PMID: 40438202 PMCID: PMC12116421 DOI: 10.1093/rb/rbaf033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2025] [Revised: 04/04/2025] [Accepted: 04/13/2025] [Indexed: 06/01/2025] Open
Abstract
Zirconia (ZrO2) has emerged as a preferred material for dental implants due to its excellent chemical inertness, absence of metal allergies and esthetic appeal. However, its limited bioactivity regarding infection resistance and early osseointegration hinders its implantation success rate compared to titanium implants. Herein, we developed a PDPA@Sr/BP coating for ZrO2 implants to address these limitations. First, inspired by the adhesive properties of mussel foot proteins, a PDPA@Sr coating enriched with positively charged amine groups and strontium (Sr) ions was applied to the ZrO2 surface. This coating stably anchored black phosphorus (BP) to the implant, effectively regulating its degradation rate and ensuring long-lasting antibacterial properties. Under near-infrared (NIR) light irradiation, BP generated localized heat, efficiently killing bacteria. Simultaneously, the release of Sr and phosphate ions from the PDPA@Sr/BP coating promoted bone formation and enhanced osseointegration. This study systematically evaluated the antibacterial effects and osseointegration-promoting properties of the PDPA@Sr/BP coating through both in vitro and in vivo experiments. The results demonstrated that compared to untreated ZrO2 surfaces, the coating significantly enhances the implant's antibacterial properties and accelerates its surface osseointegration. This study proposes an innovative strategy to improve the clinical performance of ZrO2 implants, demonstrating substantial potential for clinical translation.
Collapse
Affiliation(s)
- Huan Cheng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Jiaquan Chen
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Yan Wang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Yinyan Zhang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Tianyun Qin
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Haobo Sun
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Wen Si
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Ningyao Sun
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Yingyue Sun
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Lifeng Xiong
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Zhennan Deng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Lei Lu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Peng Gao
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Jinsong Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| |
Collapse
|
3
|
Lu X, Zhao Y, Peng X, Lu C, Wu Z, Xu H, Qin Y, Xu Y, Wang Q, Hao Y, Geng D. Comprehensive Overview of Interface Strategies in Implant Osseointegration. ADVANCED FUNCTIONAL MATERIALS 2024. [DOI: 10.1002/adfm.202418849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Indexed: 01/05/2025]
Abstract
AbstractWith the improvement of implant design and the expansion of application scenarios, orthopedic implants have become a common surgical option for treating fractures and end‐stage osteoarthritis. Their common goal is rapidly forming and long‐term stable osseointegration. However, this fixation effect is limited by implant surface characteristics and peri‐implant bone tissue activity. Therefore, this review summarizes the strategies of interface engineering (osteogenic peptides, growth factors, and metal ions) and treatment methods (porous nanotubes, hydrogel embedding, and other load‐release systems) through research on its biological mechanism, paving the way to achieve the adaptation of both and coordination between different strategies. With the transition of the osseointegration stage, interface engineering strategies have demonstrated varying therapeutic effects. Especially, the activity of osteoblasts runs almost through the entire process of osseointegration, and their physiological activities play a dominant role in bone formation. Furthermore, diseases impacting bone metabolism exacerbate the difficulty of achieving osseointegration. This review aims to assist future research on osseointegration engineering strategies to improve implant‐bone fixation, promote fracture healing, and enhance post‐implantation recovery.
Collapse
Affiliation(s)
- Xiaoheng Lu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yuhu Zhao
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Xiaole Peng
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
- Department of Orthopedics The First Affiliated Hospital of Chongqing Medical University 1 Youyi Street Chongqing 400016 China
| | - Chengyao Lu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Zebin Wu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Hao Xu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yi Qin
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yaozeng Xu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Qing Wang
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yuefeng Hao
- Orthopedics and Sports Medicine Center The Affiliated Suzhou Hospital of Nanjing Medical University 242 Guangji Street Suzhou Jiangsu 215006 China
| | - Dechun Geng
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| |
Collapse
|
4
|
Li X, Deng Z, Lu W. Mechanistic study of the effect of flexible fixation and load-bearing stress environment on fracture healing and shaping. Animal Model Exp Med 2024; 7:816-823. [PMID: 38978345 PMCID: PMC11680484 DOI: 10.1002/ame2.12448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 04/27/2024] [Accepted: 05/22/2024] [Indexed: 07/10/2024] Open
Abstract
BACKGROUND The biomechanical environment created by suture-button fixation Latarjet is conducive to the healing and shaping of the transplanted coracoid, but its mechanism remains unclear. The latest research has found that the absence of stem cell chemokine (CXCL12) impeded bone regeneration in Sonic Hedgehog (SHH)-deficient animals. However, whether the biomechanical environment affects SHH and CXCL12 function has not been studied. METHODS Rat fracture models were constructed to simulate stress environments under non-load-bearing and load-bearing conditions. The fracture healing and shaping, as well as the expression levels of SHH and CXCL12, were assessed through gross viewing, micro-computed tomography (micro-CT), and histochemical staining. RESULTS Under flexible fixation, the relative bone volume (BV/TV) of rats exposed to the load-bearing stress environment was significantly higher than that of rats under a non-load-bearing stress environment (p ≤ 0.05). Adverse bone shaping was not observed in rats subjected to flexible fixation. The levels of SHH and CXCL12 in load-bearing rats exhibited significant elevation (p ≤ 0.05). Under a load-bearing stress environment, no significant difference was observed in the BV/TV between the flexible fixation group and the rigid fixation group (p ≥ 0.05), but there was excessive hyperplasia of the fracture callus in the rigid fixation group. The levels of SHH and CXCL12 in rats subjected to rigid fixation were significantly elevated (p ≤ 0.05). CONCLUSIONS Flexible fixation and load-bearing stress environment may contribute to bone healing and shaping by influencing the levels of SHH and CXCL12, suggested that this mechanism may be relevant to the healing and shaping of the transplanted coracoid after suture-button fixation Latarjet.
Collapse
Affiliation(s)
- Xingfu Li
- Department of Sports MedicineShenzhen Second People's Hospital (The First Affiliated Hospital of Shenzhen University)ShenzhenGuangdongChina
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, National‐Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical EngineeringShenzhen University Medical SchoolShenzhenGuangdongChina
| | - Zhenhan Deng
- Department of Sports MedicineShenzhen Second People's Hospital (The First Affiliated Hospital of Shenzhen University)ShenzhenGuangdongChina
- Department of Orthopedics SurgeryThe First Affiliated Hospital of Wenzhou Medical UniversityWenzhouZhejiangChina
| | - Wei Lu
- Department of Sports MedicineShenzhen Second People's Hospital (The First Affiliated Hospital of Shenzhen University)ShenzhenGuangdongChina
| |
Collapse
|
5
|
He X, Yamada M, Watanabe J, Pengyu Q, Chen J, Egusa H. Titanium nanotopography enhances mechano-response of osteocyte three-dimensional network toward osteoblast activation. BIOMATERIALS ADVANCES 2024; 163:213939. [PMID: 38954876 DOI: 10.1016/j.bioadv.2024.213939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 06/19/2024] [Accepted: 06/27/2024] [Indexed: 07/04/2024]
Abstract
The bone turnover capability influences the acquisition and maintenance of osseointegration. The architectures of osteocyte three-dimensional (3D) networks determine the direction and activity of bone turnover through osteocyte intercellular crosstalk, which exchanges prostaglandins through gap junctions in response to mechanical loading. Titanium nanosurfaces with anisotropically patterned dense nanospikes promote the development of osteocyte lacunar-canalicular networks. We investigated the effects of titanium nanosurfaces on intercellular network development and regulatory capabilities of bone turnover in osteocytes under cyclic compressive loading. MLO-Y4 mouse osteocyte-like cell lines embedded in type I collagen 3D gels on titanium nanosurfaces promoted the formation of intercellular networks and gap junctions even under static culture conditions, in contrast to the poor intercellular connectivity in machined titanium surfaces. The osteocyte 3D network on the titanium nanosurfaces further enhanced gap junction formation after additional culturing under cyclic compressive loading simulating masticatory loading, beyond the degree observed on machined titanium surfaces. A prostaglandin synthesis inhibitor cancelled the dual effects of titanium nanosurfaces and cyclic compressive loading on the upregulation of gap junction-related genes in the osteocyte 3D culture. Supernatants from osteocyte monolayer culture on titanium nanosurfaces promoted osteocyte maturation and intercellular connections with gap junctions. With cyclic loading, titanium nanosurfaces induced expression of the regulatory factors of bone turnover in osteocyte 3D cultures, toward higher osteoblast activation than that observed on machined surfaces. Titanium nanosurfaces with anisotropically patterned dense nanospikes promoted intercellular 3D network development and regulatory function toward osteoblast activation in osteocytes activated by cyclic compressive loading, through intercellular crosstalk by prostaglandin.
Collapse
Affiliation(s)
- Xindie He
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan; Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China
| | - Masahiro Yamada
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan.
| | - Jun Watanabe
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan
| | - Qu Pengyu
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan
| | - Jiang Chen
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, PR China
| | - Hiroshi Egusa
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan; Center for Advanced Stem Cell and Regenerative Research, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan.
| |
Collapse
|
6
|
Wang H, Weng X, Chen Y, Mao S, Gao Y, Wu Q, Huang Y, Guan X, Xu Z, Lai Y. Biomimetic concentric microgrooved titanium surfaces influence bone marrow-derived mesenchymal stem cell osteogenic differentiation via H3K4 trimethylation epigenetic regulation. Dent Mater J 2024; 43:683-692. [PMID: 39135261 DOI: 10.4012/dmj.2023-327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2024]
Abstract
Material surface micromorphology can modulate cellular behavior and promote osteogenic differentiation through cytoskeletal rearrangement. Bone reconstruction requires precise regulation of gene expression in cells, a process governed by epigenetic mechanisms such as histone modifications, DNA methylation, and chromatin remodeling. We constructed osteon-mimetic concentric microgrooved titanium surfaces with different groove sizes and cultured bone marrow-derived mesenchymal stem cells (BMSCs) on the material surfaces to study how they regulate cell biological behavior and osteogenic differentiation through epigenetics. We found that the cells arranged in concentric circles along the concentric structure in the experimental group, and the concentric microgrooved surface did not inhibit cell proliferation. The results of a series of osteogenic differentiation experiments showed that the concentric microgrooves facilitated calcium deposition and promoted osteogenic differentiation of the BMSCs. Concentric microgrooved titanium surfaces that were 30 μm wide and 10 μm deep promoted osteogenic differentiation of BMSC by increasing WDR5 expression via H3K4 trimethylation upregulation.
Collapse
Affiliation(s)
- Hong Wang
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
- Stomatological Hospital of Xiamen Medical college
| | - Xinze Weng
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| | - Yan Chen
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| | - Shunjie Mao
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| | - Yuerong Gao
- Department of Stomatology of The Third Affiliated Hospital of Xi'an Medical University
| | - Qinglin Wu
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| | - Yanling Huang
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| | - Xin Guan
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| | - Zhiqiang Xu
- Department of Stomatology, Affiliated Hospital of Putian University
| | - Yingzhen Lai
- Department of Stomatology, Engineering Research Center of Fujian University for Stomatological Biomaterials, Xiamen Medical College
| |
Collapse
|
7
|
Tang T, Casagrande T, Mohammadpour P, Landis W, Lievers B, Grandfield K. Characterization of human trabecular bone across multiple length scales using a correlative approach combining X-ray tomography with LaserFIB and plasma FIB-SEM. Sci Rep 2024; 14:21604. [PMID: 39285214 PMCID: PMC11405866 DOI: 10.1038/s41598-024-72739-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Accepted: 09/10/2024] [Indexed: 09/20/2024] Open
Abstract
Three-dimensional correlative multimodal and multiscale imaging is an emerging method for investigating the complex hierarchical structure of biological materials such as bone. This approach synthesizes images acquired across multiple length scales, for the same region of interest, to provide a comprehensive view of the material structure of a sample. Here, we develop a workflow for the structural analysis of human trabecular bone using a femtosecond laser to produce a precise grid to facilitate correlation between imaging modalities and identification of structures of interest, in this case, a single trabecula within a volume of trabecular bone. Through such image registration, high resolution X-ray microscopy imaging revealed fine architectural details, including the cement sheath and bone cell lacunae of the selected bone trabecula. The selected bone volume was exposed with a combination of manual polishing and site-specific femtosecond laser ablation and then examined with plasma focused ion beam-scanning electron microscopy. This reliable and versatile correlation approach has the potential to be applied to a variety of biological tissues and traditional engineered materials. The proposed workflow has the enhanced capability for generating highly resolved and broadly contextualized structural data for a better understanding of the architectural features of a material spanning its macroscopic to nanoscopic levels.
Collapse
Affiliation(s)
- Tengteng Tang
- Department of Materials Science and Engineering, McMaster University, Hamilton, Canada.
- Center for Applied Biomechanics, Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, University of Virginia, Charlottesville, USA.
| | - Travis Casagrande
- Canadian Centre for Electron Microscopy, McMaster University, Hamilton, Canada
| | - Pardis Mohammadpour
- Canadian Centre for Electron Microscopy, McMaster University, Hamilton, Canada
| | - William Landis
- Department of Preventive and Restorative Dental Sciences, University of California at San Francisco, San Francisco, USA
| | - Brent Lievers
- Bharti School of Engineering and Computer Science, Laurentian University, Sudbury, Canada
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, Canada
| |
Collapse
|
8
|
Suliman M, Nagasawa M, Al-Omari FA, Uoshima K. The effects of collagen cross-link deficiency on osseointegration process of pure titanium implants. J Prosthodont Res 2024; 68:449-455. [PMID: 37793821 DOI: 10.2186/jpr.jpr_d_22_00249] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
PURPOSE This study aimed to investigate the effect of collagen cross-link deficiency on collagen fiber formation around an implant and its effect on the osseointegration process. METHODS Wistar rats were fed 0.1% beta-aminopropionitrile (BAPN) dissolved in water to induce collagen cross-link deficiency. Custom-made mini-implants with machined surfaces were placed proximal to the tibia. At 1, 2, and 4 weeks postoperatively, the bone area around the implant, bone-implant contact ratio, osteoclast/osteocyte activity, and osseointegration strength were evaluated using histological and immunohistochemical analyses and biomechanical tests. RESULTS Long-term disturbance of collagen cross-link formation in the BAPN group resulted in faster collagen fiber maturation than that in controls, with a defective collagen structure, low bone formation quantity, and low bone-implant contact values. Deficiency of collagen cross-links resulted in increased bone resorption and decreased osteocyte activity. CONCLUSIONS Collagen cross-linking is important for the formation of the collagen matrix, and their deficiency may impair bone activity around implants, affecting the osseointegration process.
Collapse
Affiliation(s)
- Mubarak Suliman
- Division of Bio-Prosthodontics, Department of Oral Health Science, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Masako Nagasawa
- Division of Bio-Prosthodontics, Department of Oral Health Science, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Farah A Al-Omari
- Division of Bio-Prosthodontics, Department of Oral Health Science, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Katsumi Uoshima
- Division of Bio-Prosthodontics, Department of Oral Health Science, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| |
Collapse
|
9
|
Micheletti C, DiCecco LA, Deering J, Chen W, Ervolino da Silva AC, Shah FA, Palmquist A, Okamoto R, Grandfield K. Mesoscale characterization of osseointegration around an additively manufactured genistein-coated implant. Sci Rep 2024; 14:15339. [PMID: 38961115 PMCID: PMC11222380 DOI: 10.1038/s41598-024-66058-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Accepted: 06/26/2024] [Indexed: 07/05/2024] Open
Abstract
Given the hierarchical nature of bone and bone interfaces, osseointegration, namely the formation of a direct bone-implant contact, is best evaluated using a multiscale approach. However, a trade-off exists between field of view and spatial resolution, making it challenging to image large volumes with high resolution. In this study, we combine established electron microscopy techniques to probe bone-implant interfaces at the microscale and nanoscale with plasma focused ion beam-scanning electron microscopy (PFIB-SEM) tomography to evaluate osseointegration at the mesoscale. This characterization workflow is demonstrated for bone response to an additively manufactured Ti-6Al-4V implant which combines engineered porosity to facilitate bone ingrowth and surface functionalization via genistein, a phytoestrogen, to counteract bone loss in osteoporosis. SEM demonstrated new bone formation at the implant site, including in the internal implant pores. At the nanoscale, scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy confirmed the gradual nature of the bone-implant interface. By leveraging mesoscale analysis with PFIB-SEM tomography that captures large volumes of bone-implant interface with nearly nanoscale resolution, the presence of mineral ellipsoids varying in size and orientation was revealed. In addition, a well-developed lacuno-canalicular network and mineralization fronts directed both towards the implant and away from it were highlighted.
Collapse
Affiliation(s)
- Chiara Micheletti
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Liza-Anastasia DiCecco
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Joseph Deering
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Wanqi Chen
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | | | - Furqan A Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Roberta Okamoto
- Department of Basic Sciences, Araçatuba Dental School, São Paulo State University, Araçatuba, SP, Brazil
- Research Productivity Scholarship (Process: 309408/2020-2), Araçatuba, SP, Brazil
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
- Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
10
|
Sun G, Shu T, Ma S, Li M, Qu Z, Li A. A submicron forest-like silicon surface promotes bone regeneration by regulating macrophage polarization. Front Bioeng Biotechnol 2024; 12:1356158. [PMID: 38707505 PMCID: PMC11066256 DOI: 10.3389/fbioe.2024.1356158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 03/14/2024] [Indexed: 05/07/2024] Open
Abstract
Introduction: Silicon is a major trace element in humans and a prospective supporting biomaterial to bone regeneration. Submicron silicon pillars, as a representative surface topography of silicon-based biomaterials, can regulate macrophage and osteoblastic cell responses. However, the design of submicron silicon pillars for promoting bone regeneration still needs to be optimized. In this study, we proposed a submicron forest-like (Fore) silicon surface (Fore) based on photoetching. The smooth (Smo) silicon surface and photoetched regular (Regu) silicon pillar surface were used for comparison in the bone regeneration evaluation. Methods: Surface parameters were investigated using a field emission scanning electron microscope, atomic force microscope, and contact angle instrument. The regulatory effect of macrophage polarization and succedent osteogenesis was studied using Raw264.7, MC3T3-E1, and rBMSCs. Finally, a mouse calvarial defect model was used for evaluating the promoting effect of bone regeneration on the three surfaces. Results: The results showed that the Fore surface can increase the expression of M2-polarized markers (CD163 and CD206) and decrease the expression of inflammatory cytokines, including interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α). Fore surface can promote the osteogenesis in MC3T3-E1 cells and osteoblastic differentiation of rBMSCs. Furthermore, the volume fraction of new bone and the thickness of trabeculae on the Fore surface were significantly increased, and the expression of RANKL was downregulated. In summary, the upregulation of macrophage M2 polarization on the Fore surface contributed to enhanced osteogenesis in vitro and accelerated bone regeneration in vivo. Discussion: This study strengthens our understanding of the topographic design for developing future silicon-based biomaterials.
Collapse
Affiliation(s)
- Guo Sun
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Tianyu Shu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| | - Shaoyang Ma
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| | - Meng Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| | - Zhiguo Qu
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| |
Collapse
|
11
|
Arunjaroensuk S, Nampuksa K, Monmaturapoj N, Thunyakitpisal P, Porntaveetus T, Mattheos N, Pimkhaokham A. Gene expression, micro-CT and histomorphometrical analysis of sinus floor augmentation with biphasic calcium phosphate and deproteinized bovine bone mineral: A randomized controlled clinical trial. Clin Implant Dent Relat Res 2024; 26:402-414. [PMID: 38317374 DOI: 10.1111/cid.13303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 11/08/2023] [Accepted: 01/04/2024] [Indexed: 02/07/2024]
Abstract
AIMS The aim of this randomized controlled clinical trial was to compare the gene expression, micro-CT, histomorphometrical analysis between biphasic calcium phosphate (BCP) of 70/30 ratio and deproteinized bovine bone mineral (DBBM) in sinus augmentation. MATERIALS AND METHODS Twenty-four patients in need for sinus floor augmentation through lateral approach were randomized into BCP 70/30 ratio or DBBM. After at least 6 months of healing, a total of 24 bone specimens were collected from the entire height of the augmented bone at the area of implant placement and underwent micro-CT, histomorphometric and gene expression analysis. The 12 bone specimens of BCP 70/30 ratio were equally allocated to micro-CT and histologic analysis (test group, n = 6) and gene expression analysis (test group, n = 6). Similarly, the 12 bone specimens of DBBM were also allocated to micro-CT and histologic analysis (control group, n = 6) and gene expression analysis (control group, n = 6). The newly formed bone, remaining graft materials and relative change in gene expression of four target genes were assessed. RESULTS The micro-CT results showed no statistically significant difference in the ratio of bone volume to total volume (BV/TV ratio) for the two groups (BCP 41.51% vs. DBBM 40.97%) and the same was true for residual graft material to total volume (GV/TV ratio, BCP 9.97% vs. DBBM 14.41%). Similarly, no significant difference was shown in the histological analysis in terms of bone formation, (BCP 31.43% vs. DBBM was 30.09%) and residual graft area (DBBM 40.76% vs. BCP 45.06%). With regards to gene expression, the level of ALP was lower in both groups of bone grafted specimens compared with the native bone. On the contrary, the level of OSX, IL-1B and TRAP was higher in augmented bone of both groups compared with the native bone. However, the relative difference in all gene expressions between BCP and DBBM group was not significant. CONCLUSIONS The BCP, HA/β-TCP ratio of 70/30 presented similar histological and micro-CT outcomes in terms of new bone formation and residual graft particles with DBBM. The gene expression analysis revealed different gene expression patterns between augmented and native bone, but showed no significant difference between the two biomaterials.
Collapse
Affiliation(s)
- Sirida Arunjaroensuk
- Dental Biomaterials Science Program, Graduate School, Chulalongkorn University, Bangkok, Thailand
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Katanchalee Nampuksa
- Assistive Technology and Medical Devices Research Center (A-MED), National Science and Technology Development Agency (NSTDA), Pathum Thani, Thailand
| | - Naruporn Monmaturapoj
- Assistive Technology and Medical Devices Research Center (A-MED), National Science and Technology Development Agency (NSTDA), Pathum Thani, Thailand
| | | | - Thantrira Porntaveetus
- Center of Excellence in Genomics and Precision Dentistry, Department of Physiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Atiphan Pimkhaokham
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
12
|
Deering J, Mahmoud D, Rier E, Lin Y, do Nascimento Pereira AC, Titotto S, Fang Q, Wohl GR, Deng F, Grandfield K, Elbestawi MA, Chen J. Osseointegration of functionally graded Ti6Al4V porous implants: Histology of the pore network. BIOMATERIALS ADVANCES 2023; 155:213697. [PMID: 37979439 DOI: 10.1016/j.bioadv.2023.213697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 10/11/2023] [Accepted: 11/05/2023] [Indexed: 11/20/2023]
Abstract
The additive manufacturing of titanium into porous geometries offers a means to generate low-stiffness endosseous implants with a greater surface area available for osseointegration. In this work, selective laser melting was used to produce gyroid-based scaffolds with a uniform pore size of 300 μm or functionally graded pore size from 600 μm to 300 μm. Initial in vitro assessment with Saos-2 cells showed favourable cell proliferation at pore sizes of 300 and 600 μm. Following implantation into rabbit tibiae, early histological observations at four weeks indicated some residual inflammation alongside neovessel infiltration into the scaffold interior and some early apposition of mineralized bone tissue. At twelve weeks, both scaffolds were filled with a mixture of adipocyte-rich marrow, micro-capillaries, and mineralized bone tissue. X-ray microcomputed tomography showed a higher bone volume fraction (BV/TV) and percentage of bone-implant contact (BIC) in the implants with 300 μm pores than in the functionally graded specimens. In functionally graded specimens, localized BV/TV measurement was observed to be higher in the innermost region containing smaller pores (estimated at 300-400 μm) than in larger pores at the implant exterior. The unit cell topology of the porous implant was also observed to guide the direction of bone ingrowth by conducting along the implant struts. These results suggest that in vivo experimentation is necessary alongside parametric optimization of functionally graded porous implants to predict short-term and long-term bone apposition.
Collapse
Affiliation(s)
- Joseph Deering
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Dalia Mahmoud
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada; Production Engineering Department, Faculty of Engineering, Alexandria University, Alexandria 21544, Egypt
| | - Elyse Rier
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | - Yujing Lin
- Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Anna Cecilia do Nascimento Pereira
- Center of Engineering, Modeling and Applied Social Sciences, Federal University of ABC (UFABC), Santo André, Brazil; 4D Printing and Biomimetics' (4DB) Research Group, Federal University of ABC (UFABC), Santo André, Brazil
| | - Silvia Titotto
- Center of Engineering, Modeling and Applied Social Sciences, Federal University of ABC (UFABC), Santo André, Brazil; 4D Printing and Biomimetics' (4DB) Research Group, Federal University of ABC (UFABC), Santo André, Brazil
| | - Qiyin Fang
- Department of Engineering Physics, McMaster University, Hamilton, ON, Canada
| | - Gregory R Wohl
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada; School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada; Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada
| | - Feilong Deng
- Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada; School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada; Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada.
| | - Mohamed A Elbestawi
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada.
| | - Jianyu Chen
- Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
13
|
Sun H, Shang Y, Guo J, Maihemuti A, Shen S, Shi Y, Liu H, Che J, Jiang Q. Artificial Periosteum with Oriented Surface Nanotopography and High Tissue Adherent Property. ACS APPLIED MATERIALS & INTERFACES 2023; 15:45549-45560. [PMID: 37747777 DOI: 10.1021/acsami.3c07561] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
Massive periosteal defects often significantly impair bone regeneration and repair, which have become a major clinical challenge. Unfortunately, current engineered periosteal materials can hardly currently focus on achieving high tissue adhesion property, being suitable for cell growth, and inducing cell orientation concurrently to meet the properties of nature periosteum. Additionally, the preparation of oriented surface nanotopography often relies on professional equipment. In this study, inspired by the oriented collagen structure of nature periosteum, we present a composite artificial periosteum with a layer of oriented nanotopography surface containing carbon nanotubes (CNTs), cross-linked with adhesive polydopamine (PDA) hydrogel on both terminals. An oriented surface structure that can simulate the oriented alignment of periosteal collagen fibers can be quickly and conveniently obtained via a simple stretching of the membrane in a water bath. With the help of CNTs, our artificial periosteum exhibits sufficient mechanical strength and desired oriented nanotopological structure surface, which further induces the directional arrangement of human bone marrow mesenchymal stem cells (hBMSCs) on the membrane. These oriented hBMSCs express significantly higher levels of osteogenic genes and proteins, while the resultant composite periosteum can be stably immobilized in vivo in the rat model of massive calvarial defect through the PDA hydrogel, which finally shows promising bone regeneration ability. We anticipate that the developed functional artificial periosteum has great potential in biomedical applications for the treatment of composite defects of the bone and periosteum.
Collapse
Affiliation(s)
- Han Sun
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
- Articular Orthopaedics, The Third Affiliated Hospital of Soochow University, 185 Juqian Road, Changzhou 213003, Jiangsu, PR China
| | - Yixuan Shang
- Department of Rheumatology and Immunology, Institute of Translational Medicine, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, Jiangsu, China
| | - Junxia Guo
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
| | - Abudureheman Maihemuti
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
| | - Siyu Shen
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
| | - Yong Shi
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
| | - Hao Liu
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
| | - Junyi Che
- Department of Rheumatology and Immunology, Institute of Translational Medicine, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, Jiangsu, China
| | - Qing Jiang
- Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, Nanjing 210008, Jiangsu, PR China
- State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Branch of National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Nanjing 210008, Jiangsu, PR China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong 226019, Jiangsu, PR China
- Institute of Medicinal 3D Printing, Nanjing University, Nanjing 210093, Jiangsu, PR China
- Jiangsu Engineering Research Center for 3D Bioprinting, Nanjing 210093, Jiangsu, PR China
| |
Collapse
|
14
|
Abdulla MA, Hasan RH, Al-Hyani OH. Impact of Er,Cr:YSGG Laser, Sandblast, and Acid Etching Surface Modification on Surface Topography of Biodental Titanium Implants. J Lasers Med Sci 2023; 14:e38. [PMID: 38028874 PMCID: PMC10658112 DOI: 10.34172/jlms.2023.38] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 08/14/2023] [Indexed: 12/01/2023]
Abstract
Introduction: Several techniques have been used to modify the surface of commercially pure titanium (CPTi) implants to improve osseointegration using lasers, sandblasts, sandblasts with acid etching, and other modalities. For implant-osseointegration, surface features like chemical composition of a surface, topography, and surface energy are essential. The present comparative study aimed to compare the impact of Er,Cr:YSGG laser, sandblasting, and acid etching implant surface modifications on the surface topography, roughness, and element chemical composition of the Ti dental implant. Methods: Thirty CPTi dental implants were divided into three groups according to the surface modification (n=10 for each group): Group A: Sandblasting with acid etching (SLActive), group B: Sandblasting, and group C: Er,Cr:YSGG laser surface modifications. The modified surfaces were analyzed using scanning electron microscopy (SEM), profilometer, and energy dispersive x-ray spectrometry (EDS). Results: One-way analysis of variance (ANOVA) showed that there were significant differences in the mean values of average roughness (Ra) of the three groups (P<0.05). Tukey's post hoc test showed that the average roughness (Ra) of laser-surface modification (group C) of the implant had the highest mean value (2.30 µm) among the different groups, while sandblasted surface modification (group B) of the implant had the lowest mean value (1.39 µm). The SLActive (group A) sandblast with acid etching had a mean value of 1.63 µm. SEM analysis showed that significantly modified surface topographies and different element concentrations were found within all modified groups. Conclusion: The Er,Cr:YSGG laser irradiation increased the implant surface roughness value after implant surface modification, compared to sandblasts and sandblasts with acid etching application. The observations for the SEM-EDS analysis revealed several elements with different concentrations, which were affected by the physical-chemical characteristics of the surface modification techniques. The SEM analysis showed a significant modification in implant surface topographies of the tested groups.
Collapse
Affiliation(s)
- Mohammed A Abdulla
- Department of Prosthetic Dentistry, College of Dentistry, University of Mosul, Mosul, Iraq
| | - Radhwan H Hasan
- Department of Prosthetic Dentistry, College of Dentistry, University of Mosul, Mosul, Iraq
| | - Osama Hazim Al-Hyani
- Department of Surgery and Theriogenology, College of Veterinary Medicine, University of Mosul, Mosul, Iraq
| |
Collapse
|
15
|
Detailing the influence of PEO-coated biodegradable Mg-based implants on the lacuno-canalicular network in sheep bone: A pilot study. Bioact Mater 2023; 26:14-23. [PMID: 36875051 PMCID: PMC9975618 DOI: 10.1016/j.bioactmat.2023.02.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 01/31/2023] [Accepted: 02/14/2023] [Indexed: 02/22/2023] Open
Abstract
An increasing prevalence of bone-related injuries and aging geriatric populations continue to drive the orthopaedic implant market. A hierarchical analysis of bone remodelling after material implantation is necessary to better understand the relationship between implant and bone. Osteocytes, which are housed and communicate through the lacuno-canalicular network (LCN), are integral to bone health and remodelling processes. Therefore, it is essential to examine the framework of the LCN in response to implant materials or surface treatments. Biodegradable materials offer an alternative solution to permanent implants, which may require revision or removal surgeries. Magnesium alloys have resurfaced as promising materials due to their bone-like properties and safe degradation in vivo. To further tailor their degradation capabilities, surface treatments such as plasma electrolytic oxidation (PEO) have demonstrated to slow degradation. For the first time, the influence of a biodegradable material on the LCN is investigated by means of non-destructive 3D imaging. In this pilot study, we hypothesize noticeable variations in the LCN caused by altered chemical stimuli introduced by the PEO-coating. Utilising synchrotron-based transmission X-ray microscopy, we have characterised morphological LCN differences around uncoated and PEO-coated WE43 screws implanted into sheep bone. Bone specimens were explanted after 4, 8, and 12 weeks and regions near the implant surface were prepared for imaging. Findings from this investigation indicate that the slower degradation of PEO-coated WE43 induces healthier lacunar shapes within the LCN. However, the stimuli perceived by the uncoated material with higher degradation rates induces a greater connected LCN better prepared for bone disturbance.
Collapse
|
16
|
Perez E, Salinas L, Mendoza R, Guerrero ME, Oliva J, Mayta-Tovalino F. Osseointegration of Dental Implants in Patients with Congenital and Degenerative Bone Disorders: A Literature Review. J Int Soc Prev Community Dent 2023; 13:167-172. [PMID: 37564172 PMCID: PMC10411298 DOI: 10.4103/jispcd.jispcd_51_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 03/19/2022] [Accepted: 05/03/2022] [Indexed: 08/12/2023] Open
Abstract
Aims and Objectives The aim of this study was to describe the mechanism of dental implants osseointegration in patients with congenital and degenerative genetic bone disorders. Materials and Methods A PubMed and Scopus documents search was carried out between November 2021 in the, using words such as "osseointegration," "degenerative disease," "congenital disease," and "dental implants." Results The thirteen articles selected dealt with dental implants osseointegration in patients with congenital and degenerative bone disorders. The influence and repercussion of these diseases on the bone system, as well as the osseointegration process were described from healing to bone remodeling. In addition, certain articles described some considerations to improve the osseointegration process in patients suffering from these types of conditions. Conclusions Within the limitations of this literature review we can conclude that osseointegration in patients with ectodermal dysplasia and osteoporosis could be achieved. However, the planning process for dental implant placement in these patients should be more meticulous and individualized considering the degree of tissue involvement as well as the patient's age and skeletal development compared to systemically healthy patients.
Collapse
Affiliation(s)
- Edith Perez
- Academic Department, Faculty of Dentistry, Universidad Nacional Federico Villarreal, Lima, Peru
| | - Liliana Salinas
- Academic Department, Faculty of Dentistry, Universidad Nacional Federico Villarreal, Lima, Peru
| | - Roman Mendoza
- Academic Department, Faculty of Dentistry, Universidad Nacional Federico Villarreal, Lima, Peru
| | - Maria Eugenia Guerrero
- Academic Department of Medical and Surgical Stomatology, Faculty of Dentistry, Universidad Nacional Mayor de San Marcos, Lima, Peru
| | - Jose Oliva
- Academic Department, Faculty of Dentistry, Universidad Nacional Federico Villarreal, Lima, Peru
| | | |
Collapse
|
17
|
Wan T, Zhang M, Jiang HR, Zhang YC, Zhang XM, Wang YL, Zhang PX. Tissue-Engineered Nanomaterials Play Diverse Roles in Bone Injury Repair. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:nano13091449. [PMID: 37176994 PMCID: PMC10180507 DOI: 10.3390/nano13091449] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 04/08/2023] [Accepted: 04/20/2023] [Indexed: 05/15/2023]
Abstract
Nanomaterials with bone-mimicking characteristics and easily internalized by the cell could create suitable microenvironments in which to regulate the therapeutic effects of bone regeneration. This review provides an overview of the current state-of-the-art research in developing and using nanomaterials for better bone injury repair. First, an overview of the hierarchical architecture from the macroscale to the nanoscale of natural bone is presented, as these bone tissue microstructures and compositions are the basis for constructing bone substitutes. Next, urgent clinical issues associated with bone injury that require resolution and the potential of nanomaterials to overcome them are discussed. Finally, nanomaterials are classified as inorganic or organic based on their chemical properties. Their basic characteristics and the results of related bone engineering studies are described. This review describes theoretical and technical bases for the development of innovative methods for repairing damaged bone and should inspire therapeutic strategies with potential for clinical applications.
Collapse
Affiliation(s)
- Teng Wan
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| | - Meng Zhang
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| | - Hao-Ran Jiang
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| | - Yi-Chong Zhang
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| | - Xiao-Meng Zhang
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| | - Yi-Lin Wang
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| | - Pei-Xun Zhang
- Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing 100044, China
- Key Laboratory of Trauma and Neural Regeneration, Peking University, Beijing 100044, China
- National Center for Trauma Medicine, Beijing 100044, China
| |
Collapse
|
18
|
Kupka JR, Sagheb K, Al-Nawas B, Schiegnitz E. The Sympathetic Nervous System in Dental Implantology. J Clin Med 2023; 12:jcm12082907. [PMID: 37109243 PMCID: PMC10143978 DOI: 10.3390/jcm12082907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/07/2023] [Accepted: 04/14/2023] [Indexed: 04/29/2023] Open
Abstract
The sympathetic nervous system plays a vital role in various regulatory mechanisms. These include the well-known fight-or-flight response but also, for example, the processing of external stressors. In addition to many other tissues, the sympathetic nervous system influences bone metabolism. This effect could be highly relevant concerning osseointegration, which is responsible for the long-term success of dental implants. Accordingly, this review aims to summarize the current literature on this topic and to reveal future research perspectives. One in vitro study showed differences in mRNA expression of adrenoceptors cultured on implant surfaces. In vivo, sympathectomy impaired osseointegration in mice, while electrical stimulation of the sympathetic nerves promoted it. As expected, the beta-blocker propranolol improves histological implant parameters and micro-CT measurements. Overall, the present data are considered heterogeneous. However, the available publications reveal the potential for future research and development in dental implantology, which helps to introduce new therapeutic strategies and identify risk factors for dental implant failure.
Collapse
Affiliation(s)
- Johannes Raphael Kupka
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, 55131 Mainz, Germany
| | - Keyvan Sagheb
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, 55131 Mainz, Germany
| | - Bilal Al-Nawas
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, 55131 Mainz, Germany
| | - Eik Schiegnitz
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, 55131 Mainz, Germany
| |
Collapse
|
19
|
Guided Bone Regeneration with Occlusive Titanium Barrier: A Case Report and Clinical Considerations. Biomimetics (Basel) 2023; 8:biomimetics8010106. [PMID: 36975336 PMCID: PMC10046855 DOI: 10.3390/biomimetics8010106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 02/20/2023] [Accepted: 02/28/2023] [Indexed: 03/08/2023] Open
Abstract
The need to obtain adequate bone volumes for prosthetic rehabilitation supported by implants, using different techniques and materials, represents an urgent need in modern dentistry. We report a case regarding the management of implant-prosthetic rehabilitation of the first and second upper right molars, in which no less than 4 mm of crestal bone remained to insert two implants. Regeneration of the residual bone was previously performed using a customized titanium barrier and a filler of a blood clot with tricalcium beta phosphate. The bone gain (3 mm) was evaluated by comparing CBCT images, while the implant stability (mean 70) was assessed with the ISQ measurement. A regenerated bone sample was taken for histological analysis. Guided bone regeneration obtained with a titanium barrier and blood clot allowed for the insertion of stable implants in a mature bone without heterologous material.
Collapse
|
20
|
Gomes-Ferreira PHS, Frigério PB, de Moura J, Duarte ND, de Oliveira D, Deering J, Grandfield K, Okamoto R. Evaluation of Vitamin D isolated or Associated with Teriparatide in Peri-Implant Bone Repair in Tibia of Orchiectomized Rats. BIOLOGY 2023; 12:biology12020228. [PMID: 36829506 PMCID: PMC9952949 DOI: 10.3390/biology12020228] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/25/2023] [Accepted: 01/27/2023] [Indexed: 02/04/2023]
Abstract
(1) Background: The objective of this study was to evaluate the morphometry of peri-implant bone tissue in orchiectomized rats, treated with vitamin D isolated or associated with teriparatide. (2) Methods: 24 rats were divided into 4 groups: ORQ-orchiectomy, without drug treatment, ORQ+D-orchiectomy, treated with vitamin D, ORQTERI-orchiectomy, treated with teriparatide and ORQTERI+D-orchiectomy, treated with teriparatide + vitamin D. Each animal received an implant in the tibial metaphysis. Euthanasia occurred 60 days after implant surgery. Computed microtomography (micro-CT) was performed to evaluate the parameters of volume and percentage of bone volume (BV, BV/TV), trabecular thickness (Tb.Th), number and separation of trabeculae (Tb.N, Tb.Sp) and percentage of total porosity (Po-tot). Data were subjected to 1-way ANOVA and Tukey post-test, with a significance level of 5%. (3) Results: For the parameters BV, BV/TV, Tb.Th, the ORQTERI+D group showed the highest values in relation to the other groups and for Po-tot, the lowest values were for ORQTERI+D. For Tb.Sp and Tb.N, there was no statistically significant difference when comparing intragroup results (p > 0.05). (4) Conclusions: It was possible to conclude that treatment with vitamin D associated with teriparatide increases bone volume and improves bone quality.
Collapse
Affiliation(s)
- Pedro Henrique Silva Gomes-Ferreira
- Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho—UNESP, Araçatuba 16018-805, Brazil
- Correspondence: (P.H.S.G.-F.); (R.O.); Tel.: +55-18-981109555 (P.H.S.G.-F.)
| | - Paula Buzo Frigério
- Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho—UNESP, Araçatuba 16018-805, Brazil
| | - Juliana de Moura
- Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho—UNESP, Araçatuba 16018-805, Brazil
| | - Nathália Dantas Duarte
- Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho—UNESP, Araçatuba 16018-805, Brazil
| | - Danila de Oliveira
- Department of Basic Sciences, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho—UNESP, Araçatuba 16018-805, Brazil
| | - Joseph Deering
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada
- School of Biomedical Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada
| | - Roberta Okamoto
- Department of Basic Sciences, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho—UNESP, Araçatuba 16018-805, Brazil
- Correspondence: (P.H.S.G.-F.); (R.O.); Tel.: +55-18-981109555 (P.H.S.G.-F.)
| |
Collapse
|
21
|
Sato M, Shah FA. Contributions of Resin Cast Etching to Visualising the Osteocyte Lacuno-Canalicular Network Architecture in Bone Biology and Tissue Engineering. Calcif Tissue Int 2023; 112:525-542. [PMID: 36611094 PMCID: PMC10106349 DOI: 10.1007/s00223-022-01058-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/21/2022] [Indexed: 01/09/2023]
Abstract
Recent years have witnessed an evolution of imaging technologies towards sophisticated approaches for visualising cells within their natural environment(s) and for investigating their interactions with other cells, with adjacent anatomical structures, and with implanted biomaterials. Resin cast etching (RCE) is an uncomplicated technique involving sequential acid etching and alkali digestion of resin embedded bone to observe the osteocyte lacuno-canalicular network using scanning electron microscopy. This review summarises the applicability of RCE to bone and the bone-implant interface. Quantitative parameters such as osteocyte size, osteocyte density, and number of canaliculi per osteocyte, and qualitative metrics including osteocyte shape, disturbances in the arrangement of osteocytes and canaliculi, and physical communication between osteocytes and implant surfaces can be investigated. Ageing, osteoporosis, long-term immobilisation, spinal cord injury, osteoarthritis, irradiation, and chronic kidney disease have been shown to impact osteocyte lacuno-canalicular network morphology. In addition to titanium, calcium phosphates, and bioactive glass, observation of direct connectivity between osteocytes and cobalt chromium provides new insights into the osseointegration potential of materials conventionally viewed as non-osseointegrating. Other applications include in vivo and in vitro testing of polymer-based tissue engineering scaffolds and tissue-engineered ossicles, validation of ectopic osteochondral defect models, ex vivo organ culture of whole bones, and observing the effects of gene dysfunction/deletion on the osteocyte lacuno-canalicular network. Without additional contrast staining, any resin embedded specimen (including clinical biopsies) can be used for RCE. The multitude of applications described here attest to the versatility of RCE for routine use within correlative analytical workflows, particularly in biomaterials science.
Collapse
Affiliation(s)
- Mari Sato
- Oral Biochemistry and Molecular Biology, Graduate School of Dental Medicine, Hokkaido University, Sapporo, Japan
| | - Furqan A Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
22
|
Shah FA, Jolic M, Micheletti C, Omar O, Norlindh B, Emanuelsson L, Engqvist H, Engstrand T, Palmquist A, Thomsen P. Bone without borders - Monetite-based calcium phosphate guides bone formation beyond the skeletal envelope. Bioact Mater 2023; 19:103-114. [PMID: 35441115 PMCID: PMC9005875 DOI: 10.1016/j.bioactmat.2022.03.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 03/02/2022] [Accepted: 03/07/2022] [Indexed: 12/18/2022] Open
Abstract
Calcium phosphates (CaP) represent an important class of osteoconductive and osteoinductive biomaterials. As proof-of-concept, we show how a multi-component CaP formulation (monetite, beta-tricalcium phosphate, and calcium pyrophosphate) guides osteogenesis beyond the physiological envelope. In a sheep model, hollow dome-shaped constructs were placed directly over the occipital bone. At 12 months, large amounts of bone (∼75%) occupy the hollow space with strong evidence of ongoing remodelling. Features of both compact bone (osteonal/osteon-like arrangements) and spongy bone (trabeculae separated by marrow cavities) reveal insights into function/need-driven microstructural adaptation. Pores within the CaP also contain both woven bone and vascularised lamellar bone. Osteoclasts actively contribute to CaP degradation/removal. Of the constituent phases, only calcium pyrophosphate persists within osseous (cutting cones) and non-osseous (macrophages) sites. From a translational perspective, this multi-component CaP opens up exciting new avenues for osteotomy-free and minimally-invasive repair of large bone defects and augmentation of the dental alveolar ridge.
Collapse
Affiliation(s)
- Furqan A. Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Martina Jolic
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Chiara Micheletti
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Omar Omar
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Birgitta Norlindh
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Lena Emanuelsson
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Håkan Engqvist
- Department of Engineering Sciences, Applied Materials Science Section, Uppsala University, Uppsala, Sweden
| | - Thomas Engstrand
- Department of Reconstructive Plastic Surgery, Karolinska University Hospital, Stockholm, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
23
|
Hanawa T. Biocompatibility of titanium from the viewpoint of its surface. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS 2022; 23:457-472. [PMID: 35990790 PMCID: PMC9389932 DOI: 10.1080/14686996.2022.2106156] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 07/19/2022] [Indexed: 06/15/2023]
Abstract
Among metals, Ti and majority of its alloys exhibit excellent biocompatibility or tissue compatibility. Although their high corrosion resistance is a factor in the biocompatibility of Ti and Ti alloys, it is clear that other factors exist. In this review, the corrosion resistance and passive film of Ti are compared to those of other metallic biomaterials, and their band gap energies, Egs, are compared to discuss the role of Eg in the reactivity with living tissues. From the perspective of the material's surface, it is possible to explain the excellent biocompatibility of Ti by considering the following factors: Ti ions are immediately stabilized not to show toxicity if it is released to body fluids; good balance of positive and negative charges by the dissociation of surface hydroxyl groups on the passive film; low electrostatic force of the passive film inducing a natural adsorption of proteins maintaining their natural conformation; strong property as n-type semiconductor; lower band gap energy of the passive film on Ti generating optimal reactivity; and calcium phosphate formation is caused by this reactivity. The results suggest that due to the passive oxide film, the optimal balance between high corrosion resistance and appropriate reactivity of Ti is the predominate solution for the excellent biocompatibility of Ti.
Collapse
Affiliation(s)
- Takao Hanawa
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan
- Center for Advanced Medical Engineering Research and Development, Kobe University, Kobe, Japan
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Osaka, Japan
| |
Collapse
|
24
|
Cui J, Yang Y, Chen P, Hang R, Xiao Y, Liu X, Zhang L, Sun H, Bai L. Differential Nanoscale Topography Dedicates Osteocyte-Manipulated Osteogenesis via Regulation of the TGF-β Signaling Pathway. Int J Mol Sci 2022; 23:ijms23084212. [PMID: 35457035 PMCID: PMC9027032 DOI: 10.3390/ijms23084212] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/31/2022] [Accepted: 04/07/2022] [Indexed: 02/04/2023] Open
Abstract
Osteocytes function as the master orchestrator of bone remodeling activity in the telophase of osseointegration. However, most contemporary studies focus on the manipulation of osteoblast and/or osteoclast functionality via implant surface engineering, which neglects the pivotal role of osteocytes in de novo bone formation. It is confirmative that osteocyte processes extend directly to the implant surface, but whether the surface physicochemical properties can affect the functionality of osteocytes and determine the fate of the osseointegration in the final remodeling stage remains to be determined. Titania nanotube arrays (NTAs) with distinct diameters were fabricated to investigate the relationship between the nanoscale topography and the functionality of osteocytes. In vitro results pinpointed that NTA with a diameter of 15 nm (NTA-15) significantly promote osteogenesis of osteocytes via the enhancement of spreading, proliferation, and mineralization. The osteocyte transcriptome of each group further revealed that the TGF-β signaling pathway plays a pivotal role in osteocyte-mediated osteogenesis. The in vivo study definitely mirrored the aforementioned results, that NTA-15 significantly promotes bone formation around the implant. Consequently, nanoscaled topography-induced osteocyte functionality is important in late osseointegration. This suggests that surface designs targeting osteocytes may, therefore, be a potential approach to solving the aseptic loosening of the implant, and thus strengthen osseointegration.
Collapse
Affiliation(s)
- Jingyuan Cui
- Key Laboratory for Ultrafine Materials of Ministry of Education, State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai 200237, China; (J.C.); (X.L.); (L.Z.)
- Frontiers Science Center for Materiobiology and Dynamic Chemistry, College of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Yaru Yang
- College of Materials and Textile Engineering, Jiaxing University, Jiaxing 314001, China;
| | - Peiru Chen
- State Key Laboratory of Proteomics, Beijing Proteome Research Center, National Center for Protein Sciences (Beijing), Institute of Lifeomics, Beijing 102206, China;
| | - Ruiqiang Hang
- Shanxi Key Laboratory of Biomedical Metal Materials, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China;
| | - Yin Xiao
- Australia-China Centre for Tissue Engineering and Regenerative Medicine, Queensland University of Technology, Brisbane, QLD 4000, Australia;
| | - Xueting Liu
- Key Laboratory for Ultrafine Materials of Ministry of Education, State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai 200237, China; (J.C.); (X.L.); (L.Z.)
| | - Lixin Zhang
- Key Laboratory for Ultrafine Materials of Ministry of Education, State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai 200237, China; (J.C.); (X.L.); (L.Z.)
| | - Hui Sun
- Department of Orthopedics, Shanghai Jiaotong University School of Medicine, Shanghai 200233, China
- Correspondence: (H.S.); (L.B.)
| | - Long Bai
- Key Laboratory for Ultrafine Materials of Ministry of Education, State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai 200237, China; (J.C.); (X.L.); (L.Z.)
- Frontiers Science Center for Materiobiology and Dynamic Chemistry, College of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, China
- Correspondence: (H.S.); (L.B.)
| |
Collapse
|
25
|
Choi JUA, Kijas AW, Lauko J, Rowan AE. The Mechanosensory Role of Osteocytes and Implications for Bone Health and Disease States. Front Cell Dev Biol 2022; 9:770143. [PMID: 35265628 PMCID: PMC8900535 DOI: 10.3389/fcell.2021.770143] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 12/13/2021] [Indexed: 12/14/2022] Open
Abstract
Bone homeostasis is a dynamic equilibrium between bone-forming osteoblasts and bone-resorbing osteoclasts. This process is primarily controlled by the most abundant and mechanosensitive bone cells, osteocytes, that reside individually, within chambers of porous hydroxyapatite bone matrix. Recent studies have unveiled additional functional roles for osteocytes in directly contributing to local matrix regulation as well as systemic roles through endocrine functions by communicating with distant organs such as the kidney. Osteocyte function is governed largely by both biochemical signaling and the mechanical stimuli exerted on bone. Mechanical stimulation is required to maintain bone health whilst aging and reduced level of loading are known to result in bone loss. To date, both in vivo and in vitro approaches have been established to answer important questions such as the effect of mechanical stimuli, the mechanosensors involved, and the mechanosensitive signaling pathways in osteocytes. However, our understanding of osteocyte mechanotransduction has been limited due to the technical challenges of working with these cells since they are individually embedded within the hard hydroxyapatite bone matrix. This review highlights the current knowledge of the osteocyte functional role in maintaining bone health and the key regulatory pathways of these mechanosensitive cells. Finally, we elaborate on the current therapeutic opportunities offered by existing treatments and the potential for targeting osteocyte-directed signaling.
Collapse
Affiliation(s)
- Jung Un Ally Choi
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, Australia
| | - Amanda W Kijas
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, Australia
| | - Jan Lauko
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, Australia
| | - Alan E Rowan
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
26
|
Analysis of the Osseointegration Process of Dental Implants by Electron Paramagnetic Resonance: An In Vivo Study. Dent J (Basel) 2022; 10:dj10020028. [PMID: 35200253 PMCID: PMC8871022 DOI: 10.3390/dj10020028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 02/11/2022] [Accepted: 02/14/2022] [Indexed: 12/04/2022] Open
Abstract
This research work presents an analysis of the process of an implant’s osseointegration to the jawbone tissue. The purpose of this work was to describe the processes of assimilation and the biochemical dynamics which occur during dental implantation using implants with different macro-microstructure surfaces at the level of stable free radicals using the electron paramagnetic resonance (EPR) method. The experimental investigation was conducted on seven Vietnamese minipigs over twelve months old and weighing up to 30 kg using implants with various macro-microstructure surfaces (SLA, RBM, and HSTTM) and implantation systems, namely the Adin, Sunran, Biomed, and Osstem systems. The integration of the implant into the bone triggered biochemical processes with the formation of stable free radicals. The EPR method was used to identify the formed paramagnetic species and to study the dynamics of the interaction between the surface of the implant and the bone after one and two months. The concentration of carbonate surface centers increased with the time that the implant was connected to the hard tissue. The “Sunran” and “HSTTM” were established as the most suitable implantation system and surface type, respectively, thanks to the highest rate of osseointegration (assimilation) with the bone (hard) tissue. Thus, the EPR method provides the opportunity to study implantation processes.
Collapse
|
27
|
Deshpande R, Shukla S, Kale A, Deshmukh N, Nisal A, Venugopalan P. Silk Fibroin Microparticle Scaffold for Use in Bone Void Filling: Safety and Efficacy Studies. ACS Biomater Sci Eng 2022; 8:1226-1238. [PMID: 35166518 DOI: 10.1021/acsbiomaterials.1c01103] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Silk fibroin (SF) is a natural biocompatible protein polymer extracted from cocoons of silkworm Bombyx mori. SF can be processed into a variety of different forms and shapes that can be used as scaffolds to support bone regeneration. Three-dimensional (3D) SF scaffolds have shown promise in bone-void-filling applications. In in vitro studies, it has been demonstrated that a microparticle-based SF (M-RSF) scaffold promotes the differentiation of stem cells into an osteoblastic lineage. The expression of differentiation markers was also significantly higher for M-RSF scaffolds as compared to other SF scaffolds and commercial ceramic scaffolds. In this work, we have evaluated the in vitro and in vivo biocompatibility of M-RSF scaffolds as per the ISO 10993 guidelines in a Good Laboratory Practice (GLP)-certified facility. The cytotoxicity, immunogenicity, genotoxicity, systemic toxicity, and implantation studies confirmed that the M-RSF scaffold is biocompatible. Further, the performance of the M-RSF scaffold to support bone formation was evaluated in in vivo bone implantation studies in a rabbit model. Calcium sulfate (CaSO4) scaffolds were chosen as reference material for this study as they are one of the preferred materials for bone-void-filling applications. M-RSF scaffold implantation sites showed a higher number of osteoblast and osteoclast cells as compared to CaSO4 implantation sites indicating active bone remodeling. The number density of osteocytes was double for M-RSF scaffold implantation sites, and these M-RSF scaffold implantation sites were characterized by enhanced collagen deposition, pointing toward a finer quality of the new bone formed. Moreover, the M-RSF scaffold implantation sites had a negligible incidence of secondary fractures as compared to the CaSO4 implantation sites (∼50% sites with secondary fracture), implying a reduction in postsurgical complications. Thus, the study demonstrates that the M-RSF scaffold is nontoxic for bone-void-filling applications and facilitates superior healing of fracture defects as compared to commercial calcium-based bone void fillers.
Collapse
Affiliation(s)
- Rucha Deshpande
- Serigen Mediproducts Pvt Ltd., Plot no. 9, Electronic Co-op Estate, Satara Road, Parvati Paytha, Pune 411009, India
| | - Swati Shukla
- Serigen Mediproducts Pvt Ltd., Plot no. 9, Electronic Co-op Estate, Satara Road, Parvati Paytha, Pune 411009, India
| | - Amod Kale
- Intox Private Limited, Pune, 375, Urawade, Tal. Mulshi, Pune 412115, India
| | - Narendra Deshmukh
- Intox Private Limited, Pune, 375, Urawade, Tal. Mulshi, Pune 412115, India
| | - Anuya Nisal
- Polymer Science and Engineering Dept., CSIR-National Chemical Laboratory, Homi Bhabha Road, Pashan, Pune 411008, India
| | - Premnath Venugopalan
- Polymer Science and Engineering Dept., CSIR-National Chemical Laboratory, Homi Bhabha Road, Pashan, Pune 411008, India
| |
Collapse
|
28
|
Lima FS, Matos LF, Pacheco IK, Reis F, Câmara JVF, Pierote JJA, Matos JM, Ribeiro A, Moura W, Fialho AC. Scaffold based on castor oil as an osteoconductive matrix in bone repair: biocompatibility analysis. POLIMEROS 2022. [DOI: 10.1590/0104-1428.210018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
29
|
Krstić J, Mojsilović S, Mojsilović SS, Santibanez JF. Regulation of the mesenchymal stem cell fate by interleukin-17: Implications in osteogenic differentiation. World J Stem Cells 2021; 13:1696-1713. [PMID: 34909118 PMCID: PMC8641017 DOI: 10.4252/wjsc.v13.i11.1696] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 05/14/2021] [Accepted: 10/18/2021] [Indexed: 02/06/2023] Open
Abstract
Bone regeneration is a tightly regulated process that ensures proper repair and functionality after injury. The delicate balance between bone formation and resorption is governed by cytokines and signaling molecules released during the inflammatory response. Interleukin (IL)-17A, produced in the early phase of inflammation, influences the fate of osteoprogenitors. Due to their inherent capacity to differentiate into osteoblasts, mesenchymal stem/stromal cells (MSCs) contribute to bone healing and regeneration. This review presents an overview of IL-17A signaling and the leading cellular and molecular mechanisms by which it regulates the osteogenic differentiation of MSCs. The main findings demonstrating IL-17A’s influence on osteoblastogenesis are described. To this end, divergent information exists about the capacity of IL-17A to regulate MSCs’ osteogenic fate, depending on the tissue context and target cell type, along with contradictory findings in the same cell types. Therefore, we summarize the data showing both the pro-osteogenic and anti-osteogenic roles of IL-17, which may help in the understanding of IL-17A function in bone repair and regeneration.
Collapse
Affiliation(s)
- Jelena Krstić
- Gottfried Schatz Research Center, Medical University of Graz, Graz 8010, Austria
| | - Slavko Mojsilović
- Group for Hematology and Stem Cells, Institute for Medical Research, National Institute of Republic of Serbia, University of Belgrade, Belgrade 11129, Serbia
| | - Sonja S Mojsilović
- Group for Immunology, Institute for Medical Research, National Institute of Republic of Serbia, Belgrade 11129, Serbia
| | - Juan F Santibanez
- Group for Molecular Oncology, Institute for Medical Research, National Institute of Republic of Serbia, University of Belgrade, Belgrade 11000, Serbia
- Centro Integrativo de Biología y Química Aplicada, Universidad Bernardo O’Higgins, Chile 8370993, Chile
| |
Collapse
|
30
|
Baltatu MS, Spataru MC, Verestiuc L, Balan V, Solcan C, Sandu AV, Geanta V, Voiculescu I, Vizureanu P. Design, Synthesis, and Preliminary Evaluation for Ti-Mo-Zr-Ta-Si Alloys for Potential Implant Applications. MATERIALS 2021; 14:ma14226806. [PMID: 34832207 PMCID: PMC8621571 DOI: 10.3390/ma14226806] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 10/28/2021] [Accepted: 11/08/2021] [Indexed: 12/24/2022]
Abstract
Considering the future trends of biomaterials, current studies are focused on the corrosion resistance and the mechanical properties of new materials that need to be considered in the process of strengthening alloys with additive non-toxic elements. Many kinds of titanium alloys with different biocompatible elements (Mo, Si, Zr, etc.,) have been recently developed for their similar properties with human bone. Four new different alloys were obtained and investigated regarding their microstructure, mechanical, chemical, and biological behavior (in vitro and in vivo evaluation), the alloys are as follows: Ti15Mo7Zr15Ta, Ti15Mo7Zr15Ta0.5Si, Ti15Mo7Zr15Ta0.75Si, and Ti15Mo7Zr15Ta1Si. There were changes with the addition of the silicon element such as the hardness and the modulus of elasticity increased. An MTT assay confirmed the in vitro cytocompatibility of the prepared alloys.
Collapse
Affiliation(s)
- Madalina Simona Baltatu
- Department of Technologies and Equipments for Materials Processing, Faculty of Materials Science and Engineering, Gheorghe Asachi Technical University of Iaşi, Blvd. Mangeron, No. 51, 700050 Iasi, Romania;
| | - Mihaela Claudia Spataru
- Public Health Department, Faculty of Veterinary Medicine, “Ion Ionescu de la Brad” University of Life Sciences, 3 Mihail Sadoveanu Alley, 700490 Iasi, Romania;
| | - Liliana Verestiuc
- Biomedical Sciences Department, Faculty of Medical Bioengineering, Grigore T. Popa University of Medicine and Pharmacy, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (L.V.); (V.B.)
| | - Vera Balan
- Biomedical Sciences Department, Faculty of Medical Bioengineering, Grigore T. Popa University of Medicine and Pharmacy, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (L.V.); (V.B.)
| | - Carmen Solcan
- Preclinics Department, Faculty of Veterinary Medicine, “Ion Ionescu de la Brad” University of Life Sciences, 3 Mihail Sadoveanu Alley, 700490 Iasi, Romania;
| | - Andrei Victor Sandu
- Department of Technologies and Equipments for Materials Processing, Faculty of Materials Science and Engineering, Gheorghe Asachi Technical University of Iaşi, Blvd. Mangeron, No. 51, 700050 Iasi, Romania;
- Romanian Inventors Forum, Str. Sf. P. Movila 3, 700089 Iasi, Romania
- Correspondence: (A.V.S.); (P.V.)
| | - Victor Geanta
- Engineering and Management of Metallic Material Processing Department, Faculty of Materials Science and Engineering, University Politehnica of Bucharest, 313 Spl Independentei, 060042 Bucharest, Romania;
| | - Ionelia Voiculescu
- Quality Engineering and Industrial Technologies Department, Faculty of Industrial Engineering and Robotics, University Politehnica of Bucharest, 313 Spl Independentei, 060042 Bucharest, Romania;
| | - Petrica Vizureanu
- Department of Technologies and Equipments for Materials Processing, Faculty of Materials Science and Engineering, Gheorghe Asachi Technical University of Iaşi, Blvd. Mangeron, No. 51, 700050 Iasi, Romania;
- Correspondence: (A.V.S.); (P.V.)
| |
Collapse
|
31
|
Liebi M, Lutz-Bueno V, Guizar-Sicairos M, Schönbauer BM, Eichler J, Martinelli E, Löffler JF, Weinberg A, Lichtenegger H, Grünewald TA. 3D nanoscale analysis of bone healing around degrading Mg implants evaluated by X-ray scattering tensor tomography. Acta Biomater 2021; 134:804-817. [PMID: 34333163 DOI: 10.1016/j.actbio.2021.07.060] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 07/01/2021] [Accepted: 07/23/2021] [Indexed: 11/28/2022]
Abstract
The nanostructural adaptation of bone is crucial for its biocompatibility with orthopedic implants. The bone nanostructure also determines its mechanical properties and performance. However, the bone's temporal and spatial nanoadaptation around degrading implants remains largely unknown. Here, we present insights into this important bone adaptation by applying scanning electron microscopy, elemental analysis, and small-angle X-ray scattering tensor tomography (SASTT). We extend the novel SASTT reconstruction method and provide a 3D scattering reciprocal space map per voxel of the sample's volume. From this reconstruction, parameters such as the thickness of the bone mineral particles are quantified, which provide additional information on nanostructural adaptation of bone during healing. We selected a rat femoral bone and a degrading ZX10 magnesium implant as model system, and investigated it over the course of 18 months, using a sham as control. We observe that the bone's nanostructural adaptation starts with an initially fast interfacial bone growth close to the implant, which spreads by a re-orientation of the nanostructure in the bone volume around the implant, and is consolidated in the later degradation stages. These observations reveal the complex bulk bone-implant interactions and enable future research on the related biomechanical bone responses. STATEMENT OF SIGNIFICANCE: Traumatic bone injuries are among the most frequent causes of surgical treatment, and often require the placement of an implant. The ideal implant supports and induces bone formation, while being mechanically and chemically adapted to the bone structure, ensuring a gradual load transfer. While magnesium implants fulfill these requirements, the nanostructural changes during bone healing and implant degradation remain not completely elucidated. Here, we unveil these processes in rat femoral bones with ZX10 magnesium implants and show different stages of bone healing in such a model system.
Collapse
Affiliation(s)
- Marianne Liebi
- Department of Physics, Chalmers University of Technology, 41296 Gothenburg, Sweden; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland; Center for X-ray Analytics, Swiss Federal Laboratories for Materials Science and Technology (Empa), 9014 St. Gallen, Switzerland.
| | | | | | - Bernd M Schönbauer
- Institute of Physics and Materials Science, University of Natural Resources and Life Science (BOKU), 1190 Vienna, Austria
| | - Johannes Eichler
- Department of Orthopaedics, Medical University Graz, 8010 Graz, Austria
| | | | - Jörg F Löffler
- Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Annelie Weinberg
- Department of Orthopaedics, Medical University Graz, 8010 Graz, Austria
| | - Helga Lichtenegger
- Institute of Physics and Materials Science, University of Natural Resources and Life Science (BOKU), 1190 Vienna, Austria
| | | |
Collapse
|
32
|
Wang L, Gao Z, Su Y, Liu Q, Ge Y, Shan Z. Osseointegration of a novel dental implant in canine. Sci Rep 2021; 11:4317. [PMID: 33619303 PMCID: PMC7900171 DOI: 10.1038/s41598-021-83700-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 02/05/2021] [Indexed: 01/20/2023] Open
Abstract
This study aimed to compare and verify the osseointegration performance of a novel implant (NI) in vivo, which could provide a useful scientific basis for the further development of NIs. Thirty-two NIs treated with hydrofluoric acid and anodization and sixteen control implants (CIs) were placed in the mandibles of 8 beagles. Micro-CT showed that the trabecular number (Tb.N) significantly increased and trabecular separation (Tb.Sp) significantly decreased in the NIs at 2 weeks. Significant differences were found in the trabecular thickness, Tb.N, Tb.Sp, bone surface/bone volume ratio, and bone volume/total volume ratio between the two groups from the 2nd–4th weeks. However, there were no significant differences between the two groups in the bone volume density at 2, 4, 8, or 12 weeks or bone-implant contact at 2 or 4 weeks, but the BIC in the CIs was higher than that in the NIs at the 8th and 12th weeks. Meanwhile, the histological staining showed a similar osseointegration process between the two groups over time. Overall, the NIs could be used as new potential implants after further improvement.
Collapse
Affiliation(s)
- Lingxiao Wang
- Outpatient Department of Oral and Maxillofacial Surgery, School of Stomatology, Capital Medical University, Tian Tan Xi Li No. 4, Beijing, 100050, People's Republic of China
| | - Zhenhua Gao
- Outpatient Department of Oral and Maxillofacial Surgery, School of Stomatology, Capital Medical University, Tian Tan Xi Li No. 4, Beijing, 100050, People's Republic of China
| | - Yucheng Su
- Department of Stomatology, Chinese Academy of Medical Science & Peking Union Medical College Hospital, No. 41 Damucang Hutong, Xicheng District, Beijing, 100032, People's Republic of China.,Beijing Citident Stomatology Hospital, Beijing, 100032, People's Republic of China
| | - Qian Liu
- Beijing Citident Stomatology Hospital, Beijing, 100032, People's Republic of China
| | - Yi Ge
- Department of Stomatology, Chinese Academy of Medical Science & Peking Union Medical College Hospital, No. 41 Damucang Hutong, Xicheng District, Beijing, 100032, People's Republic of China.
| | - Zhaochen Shan
- Outpatient Department of Oral and Maxillofacial Surgery, School of Stomatology, Capital Medical University, Tian Tan Xi Li No. 4, Beijing, 100050, People's Republic of China.
| |
Collapse
|
33
|
Bahraminasab M, Arab S, Safari M, Talebi A, Kavakebian F, Doostmohammadi N. In vivo performance of Al 2O 3-Ti bone implants in the rat femur. J Orthop Surg Res 2021; 16:79. [PMID: 33482866 PMCID: PMC7821505 DOI: 10.1186/s13018-021-02226-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 01/11/2021] [Indexed: 11/17/2022] Open
Abstract
Background Alumina-titanium (Al2O3-Ti) biocomposites have been recently developed with improved mechanical properties for use in heavily loaded orthopedic sites. Their biological performance, however, has not been investigated yet. Methods The aim of the present study was to evaluate the in vivo biological interaction of Al2O3-Ti. Spark plasma sintering (SPS) was used to fabricate Al2O3-Ti composites with 25 vol.%, 50 vol.%, and 75 vol.% Ti content. Pure alumina and titanium were also fabricated by the same procedure for comparison. The fabricated composite disks were cut into small bars and implanted into medullary canals of rat femurs. The histological analysis and scanning electron microscopy (SEM) observation were carried out to determine the bone formation ability of these materials and to evaluate the bone-implant interfaces. Results The histological observation showed the formation of osteoblast, osteocytes with lacuna, bone with lamellar structures, and blood vessels indicating that the healing and remodeling of the bone, and vasculature reconstruction occurred after 4 and 8 weeks of implantation. However, superior bone formation and maturation were obtained after 8 weeks. SEM images also showed stronger interfaces at week 8. There were differences between the composites in percentages of bone area (TB%) and the number of osteocytes. The 50Ti composite showed higher TB% at week 4, while 25Ti and 75Ti represented higher TB% at week 8. All the composites showed a higher number of osteocytes compared to 100Ti, particularly 75Ti. Conclusions The fabricated composites have the potential to be used in load-bearing orthopedic applications.
Collapse
Affiliation(s)
- Marjan Bahraminasab
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran. .,Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran.
| | - Samaneh Arab
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran.,Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Manouchehr Safari
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Athar Talebi
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Fatemeh Kavakebian
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Nesa Doostmohammadi
- Faculty of Metallurgical and Materials Engineering, Semnan University, Semnan, Iran
| |
Collapse
|
34
|
The Role of Epigenetic Functionalization of Implants and Biomaterials in Osseointegration and Bone Regeneration-A Review. Molecules 2020; 25:molecules25245879. [PMID: 33322654 PMCID: PMC7763898 DOI: 10.3390/molecules25245879] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/03/2020] [Accepted: 12/09/2020] [Indexed: 02/07/2023] Open
Abstract
The contribution of epigenetic mechanisms as a potential treatment model has been observed in cancer and autoimmune/inflammatory diseases. This review aims to put forward the epigenetic mechanisms as a promising strategy in implant surface functionalization and modification of biomaterials, to promote better osseointegration and bone regeneration, and could be applicable for alveolar bone regeneration and osseointegration in the future. Materials and Methods: Electronic and manual searches of the literature in PubMed, MEDLINE, and EMBASE were conducted, using a specific search strategy limited to publications in the last 5 years to identify preclinical studies in order to address the following focused questions: (i) Which, if any, are the epigenetic mechanisms used to functionalize implant surfaces to achieve better osseointegration? (ii) Which, if any, are the epigenetic mechanisms used to functionalize biomaterials to achieve better tissue regeneration? Findings from several studies have emphasized the role of miRNAs in functionalizing implants surfaces and biomaterials to promote osseointegration and bone regeneration, respectively. However, there are scarce data on the role of DNA methylation and histone modifications for these specific applications, despite being commonly applied in cancer research. Studies over the past few years have demonstrated that biomaterials are immunomodulatory rather than inert materials. In this context, epigenetics can act as next generation of advanced treatment tools for future regenerative techniques. Yet, there is a need to evaluate the efficacy/cost effectiveness of these techniques in comparison to current standards of care.
Collapse
|
35
|
Vizureanu P, Simona Bălțatu M, Victor Sandu A. Development of New Advanced Ti-Mo Alloys for Medical Applications. Biomaterials 2020. [DOI: 10.5772/intechopen.91906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The use of titanium and titanium-based alloys with applications in implantology and dentistry has made remarkable progress in the promotion of new technologies and new materials that have been developed in recent years. This is justified thanks to their excellent mechanical, physical, and biological performance. Today’s generation promotes new titanium alloys, with nontoxic elements and long-term performance and without rejection of the human body. This book chapter describes new original compositions of Ti-based alloys for medical applications, with improved properties compared to existing classical alloys (C.p. Ti, Ti6Al4V, CoCrMo, etc.). The addition of nontoxic elements such as Mo, Si, Zr, and Ta brings benefits as reduced modulus of elasticity, increased corrosion resistance, and improved biocompatibility.
Collapse
|
36
|
Verestiuc L, Spataru MC, Baltatu MS, Butnaru M, Solcan C, Sandu AV, Voiculescu I, Geanta V, Vizureanu P. New Ti-Mo-Si materials for bone prosthesis applications. J Mech Behav Biomed Mater 2020; 113:104198. [PMID: 33181439 DOI: 10.1016/j.jmbbm.2020.104198] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 09/30/2020] [Accepted: 11/02/2020] [Indexed: 12/14/2022]
Abstract
Several newly obtained titanium alloys were characterized in order to evaluate the biocompatibility and their possible application as implants. For improvement of the performances of the TiMo alloys compared to other alloys, silicon was added, targeting good mechanical and technological properties, avoiding the toxic effects for human body. Titanium is very used in medical applications, due to their extremely low toxicity and good chemical stability in different body fluids. Four Ti15MoxSi (where x = 0, 0.5, 0.75, 1.0 wt %), alloys were developed and investigated regarding microstructure, mechanical, chemical and biological behavior (in vitro and in vivo evaluation). By increasing the Si content from 0 to 1% wt., the mechanical properties of the Ti15Mo alloys were significantly improved. By increasing the Si content from 0 to 1% wt., the mechanical properties of the Ti15Mo alloys were significantly improved (about 50%) from 44.50 GPa to 19.81 GPa modulus of elasticity and the hardness values 361.28 to 188.52 HV. The cytocompatibility assessment on human line osteoblasts indicated good cell-material interactions and in vivo tests indicated a successful osseointegration, the surrounding newly bone being formed without any significant inflammatory reaction. Expression of osteopontin in the peri-implant area highlights the presence of osteogenesis and bone mineralization. Metalloproteinase-2 (gelatinase A) and metallopeptidase-9 (gelatinase B) overexpression in osteoblasts, osteoclasts and osteocytes represent the markers of normal bone remodeling. All these results suggest that the TiMoSi alloys are promising materials for orthopedics devices, since mechanical properties and biocompatibility offer conditions for applying them as biomaterial.
Collapse
Affiliation(s)
- Liliana Verestiuc
- Grigore T. Popa University of Medicine and Pharmacy, Faculty of Medical Bioengineering, Biomedical Sciences Department, 9-13 Kogalniceanu Street, 700454, Iasi, Romania
| | - Mihaela-Claudia Spataru
- Ion Ionescu de la Brad" University of Agricultural Sciences and Veterinary Medicine Iasi, 3 Mihail Sadoveanu Street, 700490, Iasi, Romania
| | - Madalina Simona Baltatu
- Gheorghe Asachi" Technical University of Iasi, Faculty of Materials Science and Engineering, 41 "D. Mangeron" Street, 700050, Iasi, Romania
| | - Maria Butnaru
- Grigore T. Popa University of Medicine and Pharmacy, Faculty of Medical Bioengineering, Biomedical Sciences Department, 9-13 Kogalniceanu Street, 700454, Iasi, Romania
| | - Carmen Solcan
- Ion Ionescu de la Brad" University of Agricultural Sciences and Veterinary Medicine Iasi, 3 Mihail Sadoveanu Street, 700490, Iasi, Romania.
| | - Andrei Victor Sandu
- Gheorghe Asachi" Technical University of Iasi, Faculty of Materials Science and Engineering, 41 "D. Mangeron" Street, 700050, Iasi, Romania; Romanian Inventors Forum, Str. Sf.P.Movila 3, Iasi, 700089, Romania
| | - Ionelia Voiculescu
- Politehnica University of Bucharest, Splaiul Independenței 313, Bucharest, Romania
| | - Victor Geanta
- Politehnica University of Bucharest, Splaiul Independenței 313, Bucharest, Romania
| | - Petrica Vizureanu
- Gheorghe Asachi" Technical University of Iasi, Faculty of Materials Science and Engineering, 41 "D. Mangeron" Street, 700050, Iasi, Romania.
| |
Collapse
|
37
|
Lateral static overload on immediately restored implants decreases the osteocyte index in peri-implant bone: a secondary analysis of a pre-clinical study in dogs. Clin Oral Investig 2020; 25:3297-3303. [PMID: 33150510 DOI: 10.1007/s00784-020-03662-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 10/27/2020] [Indexed: 01/08/2023]
Abstract
OBJECTIVES This animal study was conducted to evaluate the osteocyte index in the peri-implant bone around immediately restored implants under static lateral overload. MATERIAL AND METHODS Seven mongrel dogs received three implants on each side of the mandible. Forty-two implants were distributed into three groups (14 implants per group); each animal received two implants connected to a 4.5-mm opened expansion device (experimental group); in the other mandible side, two implants were connected into an expansion device without activation (control group); one implant each side of the mandible was left submerged (unload group). After 4 months under daily mechanical and chemical plaque control, the animals were euthanized; dental implants and surrounding bone were removed and processed to obtain thin ground sections. Histomorphometry was used to evaluate the osteocyte index in the peri-implant bone contact to implant. RESULTS A higher, statistically significant mean number of osteocytes × 10-5 μm2 (54.74 ± 23.91) was found in the control group compared with the test group (22.57 ± 22.55) (p = 0.0221). The correlation between percentage of bone-implant contact and osteocyte index for submerged implants was not statistically significant (p = 0.2667), whereas the value for immediately loaded implants was statistically significant (p = 0.0480). CONCLUSION The lower number of osteocytes in the peri-implant bone around overloaded implants could be related to the need for functional adaptation of the bone tissue to overloading and to the hypothesized involvement of the osteocytes in the maintenance of the bone matrix in the control group. CLINICAL RELEVANCE Osteocytes play a pivotal role in bone adaptation to mechanical loading, and the osteocyte network has been regarded as being the main mechanosensory mechanism.
Collapse
|
38
|
Toledano M, Toledano-Osorio M, Osorio R, Carrasco-Carmona Á, Gutiérrez-Pérez JL, Gutiérrez-Corrales A, Serrera-Figallo MA, Lynch CD, Torres-Lagares D. Doxycycline and Zinc Loaded Silica-Nanofibrous Polymers as Biomaterials for Bone Regeneration. Polymers (Basel) 2020; 12:polym12051201. [PMID: 32466191 PMCID: PMC7285172 DOI: 10.3390/polym12051201] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 05/12/2020] [Accepted: 05/22/2020] [Indexed: 12/13/2022] Open
Abstract
The main target of bone tissue engineering is to design biomaterials that support bone regeneration and vascularization. Nanostructured membranes of (MMA)1-co-(HEMA)1/(MA)3-co-(HEA)2 loaded with 5% wt of SiO2-nanoparticles (HOOC-Si-Membrane) were doped with zinc (Zn-HOOC-Si-Membrane) or doxycycline (Dox-HOOC-Si-Membrane). Critical bone defects were effectuated on six New Zealand-bred rabbit skulls and covered with the membranes. After six weeks, the bone architecture was evaluated with micro computed tomography. Three histological analyses were utilized to analyse bone regeneration, including von Kossa silver nitrate, toluidine blue and fluorescence. All membrane-treated defects exhibited higher number of osteocytes and bone perimeter than the control group without the membrane. Zn-HOOC-Si-Membranes induced higher new bone and osteoid area than those treated with HOOC-Si-Membranes, and control group, respectively. Zn-HOOC-Si-Membranes and Dox-HOOC-Si-Membranes attained the lowest ratio M1 macrophages/M2 macrophages. Dox-HOOC-Si-Membranes caused the lowest number of osteoclasts, and bone density. At the trabecular new bone, Zn-HOOC-Si-Membranes produced the highest angiogenesis, bone thickness, connectivity, junctions and branches. Zn-HOOC-Si-Membranes enhanced biological activity, attained a balanced remodeling, and achieved the greatest regenerative efficiency after osteogenesis and angiogenesis assessments. The bone-integrated Zn-HOOC-Si-Membranes can be considered as bioactive modulators provoking a M2 macrophages (pro-healing cells) increase, being a potential biomaterial for promoting bone repair.
Collapse
Affiliation(s)
- Manuel Toledano
- Dental Materials Section, Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain; (M.T.); (M.T.-O.); (Á.C.-C.)
| | - Manuel Toledano-Osorio
- Dental Materials Section, Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain; (M.T.); (M.T.-O.); (Á.C.-C.)
| | - Raquel Osorio
- Dental Materials Section, Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain; (M.T.); (M.T.-O.); (Á.C.-C.)
- Correspondence: ; Tel.: +34-958243789
| | - Álvaro Carrasco-Carmona
- Dental Materials Section, Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain; (M.T.); (M.T.-O.); (Á.C.-C.)
| | - José-Luis Gutiérrez-Pérez
- Oral Surgery Section, Faculty of Dentistry, University of Sevilla, Avicena s/n, 41009 Sevilla, Spain; (J.-L.G.-P.); (A.G.-C.); (M.-A.S.-F.); (D.T.-L.)
| | - Aida Gutiérrez-Corrales
- Oral Surgery Section, Faculty of Dentistry, University of Sevilla, Avicena s/n, 41009 Sevilla, Spain; (J.-L.G.-P.); (A.G.-C.); (M.-A.S.-F.); (D.T.-L.)
| | - María-Angeles Serrera-Figallo
- Oral Surgery Section, Faculty of Dentistry, University of Sevilla, Avicena s/n, 41009 Sevilla, Spain; (J.-L.G.-P.); (A.G.-C.); (M.-A.S.-F.); (D.T.-L.)
| | - Christopher D. Lynch
- University Dental School & Hospital/University College Cork, Wilton, T12 E8YV Cork, Ireland;
| | - Daniel Torres-Lagares
- Oral Surgery Section, Faculty of Dentistry, University of Sevilla, Avicena s/n, 41009 Sevilla, Spain; (J.-L.G.-P.); (A.G.-C.); (M.-A.S.-F.); (D.T.-L.)
| |
Collapse
|
39
|
Zheng H, Tian Y, Gao Q, Yu Y, Xia X, Feng Z, Dong F, Wu X, Sui L. Hierarchical Micro-Nano Topography Promotes Cell Adhesion and Osteogenic Differentiation via Integrin α2-PI3K-AKT Signaling Axis. Front Bioeng Biotechnol 2020; 8:463. [PMID: 32509748 PMCID: PMC7248375 DOI: 10.3389/fbioe.2020.00463] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 04/21/2020] [Indexed: 12/17/2022] Open
Abstract
Surface topography dictates important aspects of cell biological behaviors. In our study, hierarchical micro-nano topography (SLM-AHT) with micro-scale grooves and nano-scale pores was fabricated and compared with smooth topography (S) and irregular micro-scale topography (SLA) surfaces to investigate mechanism involved in cell-surface interactions. Integrin α2 had a higher expression level on SLM-AHT surface compared with S and SLA surfaces, and the expression levels of osteogenic markers icluding Runx2, Col1a1, and Ocn were concomitantly upregulated on SLM-AHT surface. Moreover, formation of mature focal adhesions were significantly enhanced in SLM-AHT group. Noticablely, silencing integrin α2 could wipe out the difference of osteogenic gene expression among surfaces with different topography, indicating a crucial role of integrin α2 in topography induced osteogenic differentiation. In addition, PI3K-AKT signaling was proved to be regulated by integrin α2 and consequently participate in this process. Taken together, our findings illustrated that integrin α2-PI3K-AKT signaling axis plays a key role in hierarchical micro-nano topography promoting cell adhesion and osteogenic differentiation.
Collapse
Affiliation(s)
- Huimin Zheng
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Yujuan Tian
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Qian Gao
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Yingjie Yu
- Health Science Center, Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Shenzhen, China
| | - Xianyou Xia
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Zhipeng Feng
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
| | - Feng Dong
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Xudong Wu
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Lei Sui
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
| |
Collapse
|
40
|
YILMAZ D, Furuncuoğlu H, VAROL O, AKIN H. Evaluation of Thermal Variations of Irrigation on the Osseointegration of Dental Implants: An In vivo Study in Rabbit Models. CUMHURIYET DENTAL JOURNAL 2020. [DOI: 10.7126/cumudj.669313] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
41
|
Zima A, Czechowska J, Szponder T, Ślósarczyk A. In vivo behavior of biomicroconcretes based on α-tricalcium phosphate and hybrid hydroxyapatite/chitosan granules and sodium alginate. J Biomed Mater Res A 2020; 108:1243-1255. [PMID: 32056372 DOI: 10.1002/jbm.a.36898] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 01/31/2020] [Accepted: 02/04/2020] [Indexed: 11/08/2022]
Abstract
The current studies provide insights into how predictions based on results of physicochemical and in vitro tests are consistent with the results of in vivo studies. The new biomicroconcrete type materials were obtained by mixing the solid phase, composed of hybrid hydroxyapatite/chitosan granules and highly reactive α-tricalcium phosphate powder, used as the setting agent. This approach guaranteed a good adhesion of the continuous cement phase to the surface of granules. It has been demonstrated that developed biomicroconcretes are surgically handy, possessed favorable physicochemical and biological properties and can be considered as effective bone implant material. The hierarchical porosity and compressive strength (2-6 MPa) similar to cancellous bone made them suitable for low-load bearing applications. Despite the fact that final setting times of biomicroconcretes were longer than recommended in the literature (i.e., exceeded 15 min), their short cohesion time allows for a successful implantation in a rabbit femoral defect model. Histological analysis and Raman studies revealed newly formed bone tissues around the sides of implanted materials. Furthermore, the process of neovascularization and reconstruction of the bone tissue, as well as a reverse scaffolding process, was visible. No signs of inflammation or adverse tissue reactions were observed during the experiment.
Collapse
Affiliation(s)
- Aneta Zima
- Faculty of Materials Science and Ceramics, AGH-UST University of Science and Technology, Krakow, Poland
| | - Joanna Czechowska
- Faculty of Materials Science and Ceramics, AGH-UST University of Science and Technology, Krakow, Poland
| | - Tomasz Szponder
- Faculty of Veterinary Medicine, University of Life Sciences, Lublin, Poland
| | - Anna Ślósarczyk
- Faculty of Materials Science and Ceramics, AGH-UST University of Science and Technology, Krakow, Poland
| |
Collapse
|
42
|
Affiliation(s)
- Takao HANAWA
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| |
Collapse
|
43
|
Naghshbandi J. The influence of local and systemic factors upon dental implant osseointegration: A critical review. SAUDI JOURNAL OF ORAL SCIENCES 2020. [DOI: 10.4103/sjos.sjoralsci_79_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
44
|
Cagna DR, Donovan TE, McKee JR, Eichmiller F, Metz JE, Albouy JP, Marzola R, Murphy KR, Troeltzsch M. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2019; 122:198-269. [PMID: 31405523 DOI: 10.1016/j.prosdent.2019.05.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 05/15/2019] [Indexed: 12/13/2022]
Abstract
This comprehensive review of the 2018 dental literature is provided to inform busy dentists about progress in the profession. Developed by the Committee on Scientific Investigation of the American Academy of Restorative Dentistry, each author brings discipline-specific expertise to one of the 8 sections of the report including (1) prosthodontics; (2) periodontics, alveolar bone, and peri-implant tissues; (3) implant dentistry; (4) dental materials and therapeutics; (5) occlusion and temporomandibular disorders; (6) sleep-related breathing disorders; (7) oral medicine and oral and maxillofacial surgery; and (8) dental caries and cariology. The report targets important information that will likely influence day-to-day treatment decisions. Each review is not intended to stand alone but to update interested readers so that they may visit source materials if greater detail is desired. As the profession continues its march toward evidence-based clinical decision-making, an already voluminous library of potentially valuable dental literature continues to grow. It is the intention of this review and its authors to provide assistance in navigating the extensive dental literature published in 2018. It is our hope that readers find this work useful in the clinical management of patients moving forward.
Collapse
Affiliation(s)
- David R Cagna
- Professor, Associate Dean, and Residency Director, Department of Prosthodontics, University of Tennessee Health Sciences Center, College of Dentistry, Memphis, Tenn.
| | - Terence E Donovan
- Professor and Head of Biomaterials, Department of Restorative Sciences, University of North Carolina School of Dentistry, Chapel Hill, NC
| | - James R McKee
- Private practice, Restorative Dentistry, Downers Grove, Ill
| | | | - James E Metz
- Private practice, Restorative Dentistry, Columbus, Ohio
| | - Jean-Pierre Albouy
- Assistant Professor, Department of Restorative Sciences, University of North Carolina School of Dentistry, Chapel Hill, NC
| | | | - Kevin R Murphy
- Associate Clinical Professor, Department of Periodontics, University of Maryland College of Dentistry, Baltimore, MD; Private practice, Periodontics and Prosthodontics, Baltimore, MD
| | | |
Collapse
|
45
|
New Implant Macrogeometry to Improve and Accelerate the Osseointegration: An In Vivo Experimental Study. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9153181] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A new implant design with healing chambers in the threads was analyzed and compared with a conventional implant macrogeometry, both implants models with and without surface treatment. Eighty conical implants were prepared using commercially pure titanium (grade IV) by the company Implacil De Bortoli (São Paulo, Brazil). Four groups were performed, as described below: Group 1 (G1), traditional conical implants with surface treatment; group 2 (G2), traditional conical implants without surface treatment (machined surface); group 3 (G3), new conical implant design with surface treatment; group 4 (G4), new conical implant design without surface treatment. The implants were placed in the two tibias (n = 2 implants per tibia) of twenty New Zealand rabbits determined by randomization. The animals were euthanized after 15 days (Time 1) and 30 days (Time 2). The parameters evaluated were the implant stability quotient (ISQ), removal torque values (RTv), and histomorphometric evaluation to determine the bone to implant contact (%BIC) and bone area fraction occupancy (BAFO%). The results showed that the implants with the macrogeometry modified with healing chambers in the threads produced a significant enhancement in the osseointegration, accelerating this process. The statistical analyses of ISQ and RTv showed a significative statistical difference between the groups in both time periods of evaluation (p ≤ 0.0001). Moreover, an important increase in the histological parameters were found for groups G3 and G4, with significant statistical differences to the BIC% (in the Time 1 p = 0.0406 and in the Time 2 p < 0.0001) and the BAFO% ((in the Time 1 p = 0.0002 and in the Time 2 p = 0.0045). In conclusion, the result data showed that the implants with the new macrogeometry, presenting the healing chambers in the threads, produced a significant enhancement in the osseointegration, accelerating the process.
Collapse
|
46
|
Hanawa T. Titanium-Tissue Interface Reaction and Its Control With Surface Treatment. Front Bioeng Biotechnol 2019; 7:170. [PMID: 31380361 PMCID: PMC6650641 DOI: 10.3389/fbioe.2019.00170] [Citation(s) in RCA: 124] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 07/03/2019] [Indexed: 12/17/2022] Open
Abstract
Titanium (Ti) and its alloys are widely used for medical and dental implant devices-artificial joints, bone fixators, spinal fixators, dental implant, etc. -because they show excellent corrosion resistance and good hard-tissue compatibility (bone formation and bone bonding ability). Osseointegration is the first requirement of the interface structure between titanium and bone tissue. This concept of osseointegration was immediately spread to dental-materials researchers worldwide to show the advantages of titanium as an implant material compared with other metals. Since the concept of osseointegration was developed, the cause of osseointegration has been actively investigated. The surface chemical state, adsorption characteristics of protein, and bone tissue formation process have also been evaluated. To accelerate osseointegration, roughened and porous surfaces are effective. HA and TiO2 coatings prepared by plasma spray and an electrochemical technique, as well as alkalinization of the surface, are also effective to improve hard-tissue compatibility. Various immobilization techniques for biofunctional molecules have been developed for bone formation and prevention of platelet and bacteria adhesion. These techniques make it possible to apply Ti to a scaffold of tissue engineering. The elucidation of the mechanism of the excellent biocompatibility of Ti can provide a shorter way to develop optimal surfaces. This review should enhance the understanding of the properties and biocompatibility of Ti and highlight the significance of surface treatment.
Collapse
Affiliation(s)
- Takao Hanawa
- Department of Metallic Biomaterials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
47
|
Shah FA, Ruscsák K, Palmquist A. 50 years of scanning electron microscopy of bone-a comprehensive overview of the important discoveries made and insights gained into bone material properties in health, disease, and taphonomy. Bone Res 2019; 7:15. [PMID: 31123620 PMCID: PMC6531483 DOI: 10.1038/s41413-019-0053-z] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 04/09/2019] [Accepted: 04/11/2019] [Indexed: 02/06/2023] Open
Abstract
Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair. The scanning electron microscope (SEM) is among the most frequently used instruments for examining bone. It offers the key advantage of very high spatial resolution coupled with a large depth of field and wide field of view. Interactions between incident electrons and atoms on the sample surface generate backscattered electrons, secondary electrons, and various other signals including X-rays that relay compositional and topographical information. Through selective removal or preservation of specific tissue components (organic, inorganic, cellular, vascular), their individual contribution(s) to the overall functional competence can be elucidated. With few restrictions on sample geometry and a variety of applicable sample-processing routes, a given sample may be conveniently adapted for multiple analytical methods. While a conventional SEM operates at high vacuum conditions that demand clean, dry, and electrically conductive samples, non-conductive materials (e.g., bone) can be imaged without significant modification from the natural state using an environmental scanning electron microscope. This review highlights important insights gained into bone microstructure and pathophysiology, bone response to implanted biomaterials, elemental analysis, SEM in paleoarchaeology, 3D imaging using focused ion beam techniques, correlative microscopy and in situ experiments. The capacity to image seamlessly across multiple length scales within the meso-micro-nano-continuum, the SEM lends itself to many unique and diverse applications, which attest to the versatility and user-friendly nature of this instrument for studying bone. Significant technological developments are anticipated for analysing bone using the SEM.
Collapse
Affiliation(s)
- Furqan A. Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Krisztina Ruscsák
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
48
|
Marenzi G, Impero F, Scherillo F, Sammartino JC, Squillace A, Spagnuolo G. Effect of Different Surface Treatments on Titanium Dental Implant Micro-Morphology. MATERIALS 2019; 12:ma12050733. [PMID: 30836588 PMCID: PMC6427554 DOI: 10.3390/ma12050733] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 02/27/2019] [Accepted: 03/01/2019] [Indexed: 12/13/2022]
Abstract
Background: Titanium dental implants are today widely used with osseointegration mainly dependently on the implant surface properties. Different processing routes lead to different surface characteristics resulting, of course, in different in situ behaviors of the implants. Materials: The effect of different treatments, whether mechanical or chemical, on the surface morphology of titanium implants were investigated. To this aim, various experimental methods, including roughness analysis as well scanning electron microscope (SEM) observations, were applied. Results: The results showed that, in contrast to the mechanical treatments, the chemical ones gave rise to a more irregular surface. SEM observations suggested that where commercial pure titanium was used, the chemical treatments provided implant surfaces without contaminations. In contrast, sandblasted implants could cause potential risks of surface contamination because of the presence of blasting particles remnants. Conclusions: The examined implant surfaces showed different roughness levels in relation to the superficial treatment applied. The acid-etched surfaces were characterized by the presence of deeper valleys and higher peaks than the sandblasted surfaces. For this reason, acid-etched surfaces can be more easily damaged by the stress produced by the peri-implant bone during surgical implant placement.
Collapse
Affiliation(s)
- Gaetano Marenzi
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", Via Pansini 5, 80131 Naples, Italy.
| | - Filomena Impero
- Department of Chemical, Materials and Industrial Production Engineering, University of Naples "Federico II", P.le Tecchio 80, 80125 Napoli, Italy.
| | - Fabio Scherillo
- Department of Chemical, Materials and Industrial Production Engineering, University of Naples "Federico II", P.le Tecchio 80, 80125 Napoli, Italy.
| | - Josè Camilla Sammartino
- Department of Biology and Biotechnology "L. Spallanzani", University of Pavia, Via Ferrata 1, 27100 Pavia, Italy.
| | - Antonino Squillace
- Department of Chemical, Materials and Industrial Production Engineering, University of Naples "Federico II", P.le Tecchio 80, 80125 Napoli, Italy.
| | - Gianrico Spagnuolo
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", Via Pansini 5, 80131 Naples, Italy.
- Institute of Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia.
| |
Collapse
|
49
|
Man Y, Yu HY, Wang ZL, Wu Y, Yang BC, Cheng L, Zhou XD, Sun Y. [Criteria for success in dental implants]. HUA XI KOU QIANG YI XUE ZA ZHI = HUAXI KOUQIANG YIXUE ZAZHI = WEST CHINA JOURNAL OF STOMATOLOGY 2019; 37:1-6. [PMID: 30854810 DOI: 10.7518/hxkq.2019.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
With the comprehensive application and development of implant dentistry in recent years, multi-institutional data have supported a large number of clinical research findings. A consensus was gradually reached on the evaluation of the state and effect of implants and types of indicators that were selected after restoration. This study aims to examine the frequently used criteria to define treatment success in implant dentistry.
Collapse
Affiliation(s)
- Yi Man
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Implant, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Hai-Yang Yu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Zuo-Lin Wang
- Dept. of Implant, The Afficiated Stomatology Hospital of Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai 200072, China
| | - Yao Wu
- Engineering Research Center in Biomaterials, Sichuan University & Sichuan Guojia Biomaterials Engineering Technology Limited Company, Chengdu 610064, China
| | - Bang-Cheng Yang
- Engineering Research Center in Biomaterials, Sichuan University & Sichuan Guojia Biomaterials Engineering Technology Limited Company, Chengdu 610064, China
| | - Lei Cheng
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Cariology and Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Xue-Dong Zhou
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Cariology and Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Yao Sun
- Dept. of Implant, The Afficiated Stomatology Hospital of Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai 200072, China
| |
Collapse
|
50
|
Shah FA, Thomsen P, Palmquist A. Osseointegration and current interpretations of the bone-implant interface. Acta Biomater 2019; 84:1-15. [PMID: 30445157 DOI: 10.1016/j.actbio.2018.11.018] [Citation(s) in RCA: 187] [Impact Index Per Article: 31.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 10/28/2018] [Accepted: 11/12/2018] [Indexed: 02/07/2023]
Abstract
Complex physical and chemical interactions take place in the interface between the implant surface and bone. Various descriptions of the ultrastructural arrangement to various implant design features, ranging from solid and macroporous geometries to surface modifications on the micron-, submicron-, and nano- levels, have been put forward. Here, the current knowledge regarding structural organisation of the bone-implant interface is reviewed with a focus on solid devices, mainly metal (or alloy) intended for permanent anchorage in bone. Certain biomaterials that undergo surface and bulk degradation are also considered. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin. In the published literature, as many as eight distinct arrangements of the bone-implant interface ultrastructure have been described. The interpretation is influenced by the in vivo model and species-specific characteristics, healing time point(s), physico-chemical properties of the implant surface, implant geometry, sample preparation route(s) and associated artefacts, analytical technique(s) and their limitations, and non-compromised vs compromised local tissue conditions. The understanding of the ultrastructure of the interface under experimental conditions is rapidly evolving due to the introduction of novel techniques for sample preparation and analysis. Nevertheless, the current understanding of the interface zone in humans in relation to clinical implant performance is still hampered by the shortcomings of clinical methods for resolving the finer details of the bone-implant interface. STATEMENT OF SIGNIFICANCE: Being a hierarchical material by design, the overall strength of bone is governed by composition and structure. Understanding the structure of the bone-implant interface is essential in the development of novel bone repair materials and strategies, and their long-term success. Here, the current knowledge regarding the eventual structural organisation of the bone-implant interface is reviewed, with a focus on solid devices intended for permanent anchorage in bone, and certain biomaterials that undergo surface and bulk degradation. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin.
Collapse
|