1
|
Janasik D, Imielska P, Krawczyk T. Tuning the pH of Activation of Fluorinated Hydrazone-Based Switches─A Pathway to Versatile 19F Magnetic Resonance Imaging Contrast Agents. ACS Sens 2023; 8:721-727. [PMID: 36695323 PMCID: PMC9972467 DOI: 10.1021/acssensors.2c02251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Molecular switches have become an area of great interest in recent years. They are explored as high-density data storage and organic diodes in molecular electronics as well as chemosensors due to their ability to undergo a transition between well-defined structures under the action of external stimuli. One of the types of such switches is hydrazones. They work by changing the configuration from E to Z under the influence of pH or light. The change in configuration is accompanied by a change in the absorption band and changes in the nuclear magnetic resonance (NMR) spectrum. In this publication, the structure-property relationship of fluorinated hydrazone switches was established. A linear relationship between the Hammett substituent constants and the pH where the switching occurs was found. Introduction of strong electron-donating groups allowed obtaining a hydrazone switch of pKa = 6 suitable for application in 19F MRI as contrast agents.
Collapse
Affiliation(s)
- Dawid Janasik
- Department of Chemical Organic Technology and Petrochemistry, Silesian University of Technology, Krzywoustego 4, 44-100Gliwice, Poland
| | - Patrycja Imielska
- Department of Chemical Organic Technology and Petrochemistry, Silesian University of Technology, Krzywoustego 4, 44-100Gliwice, Poland
| | - Tomasz Krawczyk
- Department of Chemical Organic Technology and Petrochemistry, Silesian University of Technology, Krzywoustego 4, 44-100Gliwice, Poland
| |
Collapse
|
2
|
A role for dynamic contrast-enhanced magnetic resonance imaging in predicting tumour radiation response. Br J Cancer 2016; 114:1206-11. [PMID: 27140315 PMCID: PMC4891499 DOI: 10.1038/bjc.2016.110] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Revised: 02/25/2016] [Accepted: 03/22/2016] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Dynamic contrast-enhanced (DCE) MRI may provide prognostic insights into tumour radiation response. This study examined quantitative DCE MRI parameters in rat tumours, as potential biomarkers of tumour growth delay following single high-dose irradiation. METHODS Dunning R3327-AT1 prostate tumours were evaluated by DCE MRI following intravenous injection of Gd-DTPA. The next day tumours were irradiated (single dose of 30 Gy), while animals breathed air (n=4) or oxygen (n=4); two animals were non-irradiated controls. Growth was followed and tumour volume-quadrupling time (T4) was compared with pre-irradiation DCE assessments. RESULTS Irradiation caused significant tumour growth delay (T4 ranged from 28 to 48 days for air-breathing rats, and 40 to 75 days for oxygen-breathing rats) compared with the controls (T4=7 to 9 days). A strong correlation was observed between T4 and extravascular-extracellular volume fraction (ve) irrespective of the gas inhaled during irradiation. There was also a correlation between T4 and volume transfer constant (K(trans)) for the air-breathing group alone. CONCLUSIONS The data provide rationale for expanded studies of other tumour sites, types and progressively patients, and are potentially significant, as many patients undergo contrast-enhanced MRI as part of treatment planning.
Collapse
|
3
|
Frank J, Gündel D, Drescher S, Thews O, Mäder K. Injectable LiNc-BuO loaded microspheres as in vivo EPR oxygen sensors after co-implantation with tumor cells. Free Radic Biol Med 2015; 89:741-9. [PMID: 26459034 DOI: 10.1016/j.freeradbiomed.2015.10.401] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 10/03/2015] [Accepted: 10/08/2015] [Indexed: 10/22/2022]
Abstract
Electron paramagnetic resonance (EPR) oximetry is a technique which allows accurate and repeatable oxygen measurements. We encapsulated a highly oxygen sensitive particulate EPR spin probe into microparticles to improve its dispersibility and, hence, facilitate the administration. These biocompatible, non-toxic microspheres contained 5-10 % (w/w) spin probe and had an oxygen sensitivity of 0.60 ± 0.01 µT/mmHg. To evaluate the performance of the microparticles as oxygen sensors, they were co-implanted with syngeneic tumor cells in 2 different rat strains. Thus, tissue injury was avoided and the microparticles were distributed all over the tumor tissue. Dynamic changes of the intratumoral oxygen partial pressure during inhalation of 8 %, 21 %, or 100 % oxygen were monitored in vivo by EPR spectroscopy and quantified. Values were verified in vivo by invasive fluorometric measurements using Oxylite probes and ex vivo by pimonidazole adduct accumulation. There were no hints that the tumor physiology or tissue oxygenation had been altered by the microparticles. Hence, these microprobes offer great potential as oxygen sensors in preclinical research, not only for EPR spectroscopy but also for EPR imaging. For instance, the assessment of tissue oxygenation during therapeutic interventions might help understanding pathophysiological processes and lead to an individualized treatment planning or the use of formulations with hypoxia triggered release of active agents.
Collapse
Affiliation(s)
- Juliane Frank
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale), Germany
| | - Daniel Gündel
- Julius-Bernstein-Institute of Physiology, Martin Luther University Halle-Wittenberg, Magdeburger Str. 6, 06112 Halle (Saale), Germany
| | - Simon Drescher
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale), Germany
| | - Oliver Thews
- Julius-Bernstein-Institute of Physiology, Martin Luther University Halle-Wittenberg, Magdeburger Str. 6, 06112 Halle (Saale), Germany.
| | - Karsten Mäder
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale), Germany.
| |
Collapse
|
4
|
Xue S, Qiao J, Jiang J, Hubbard K, White N, Wei L, Li S, Liu ZR, Yang JJ. Design of ProCAs (protein-based Gd(3+) MRI contrast agents) with high dose efficiency and capability for molecular imaging of cancer biomarkers. Med Res Rev 2014; 34:1070-99. [PMID: 24615853 DOI: 10.1002/med.21313] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Magnetic resonance imaging (MRI) is the leading imaging technique for disease diagnostics, providing high resolution, three-dimensional images noninvasively. MRI contrast agents are designed to improve the contrast and sensitivity of MRI. However, current clinically used MRI contrast agents have relaxivities far below the theoretical upper limit, which largely prevent advancing molecular imaging of biomarkers with desired sensitivity and specificity. This review describes current progress in the development of a new class of protein-based MRI contrast agents (ProCAs) with high relaxivity using protein design to optimize the parameters that govern relaxivity. Further, engineering with targeting moiety allows these contrast agents to be applicable for molecular imaging of prostate cancer biomarkers by MRI. The developed protein-based contrast agents also exhibit additional in vitro and in vivo advantages for molecular imaging of disease biomarkers, such as high metal-binding stability and selectivity, reduced toxicity, proper blood circulation time, and higher permeability in tumor tissue in addition to improved relaxivities.
Collapse
Affiliation(s)
- Shenghui Xue
- Departments of Chemistry and Biology, Georgia State University, Atlanta, Georgia; Center for Diagnostics & Therapeutics (CDT), Georgia State University, Atlanta, Georgia; Center for Biotechnology and Drug Design, Georgia State University, Atlanta, Georgia
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Xue S, Qiao J, Pu F, Cameron M, Yang JJ. Design of a novel class of protein-based magnetic resonance imaging contrast agents for the molecular imaging of cancer biomarkers. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2013; 5:163-79. [PMID: 23335551 DOI: 10.1002/wnan.1205] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Magnetic resonance imaging (MRI) of disease biomarkers, especially cancer biomarkers, could potentially improve our understanding of the disease and drug activity during preclinical and clinical drug treatment and patient stratification. MRI contrast agents with high relaxivity and targeting capability to tumor biomarkers are highly required. Extensive work has been done to develop MRI contrast agents. However, only a few limited literatures report that protein residues can function as ligands to bind Gd(3+) with high binding affinity, selectivity, and relaxivity. In this paper, we focus on reporting our current progress on designing a novel class of protein-based Gd(3+) MRI contrast agents (ProCAs) equipped with several desirable capabilities for in vivo application of MRI of tumor biomarkers. We will first discuss our strategy for improving the relaxivity by a novel protein-based design. We then discuss the effect of increased relaxivity of ProCAs on improving the detection limits for MRI contrast agent, especially for in vivo application. We will further report our efforts to improve in vivo imaging capability and our achievement in molecular imaging of cancer biomarkers with potential preclinical and clinical applications.
Collapse
Affiliation(s)
- Shenghui Xue
- Departments of Chemistry and Biology, Center for Diagnostics & Therapeutics, Georgia State University, Atlanta, GA, USA
| | | | | | | | | |
Collapse
|
6
|
Yeom CJ, Zeng L, Zhu Y, Hiraoka M, Harada H. Strategies To Assess Hypoxic/HIF-1-Active Cancer Cells for the Development of Innovative Radiation Therapy. Cancers (Basel) 2011; 3:3610-31. [PMID: 24212970 PMCID: PMC3759213 DOI: 10.3390/cancers3033610] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2011] [Revised: 08/12/2011] [Accepted: 09/09/2011] [Indexed: 11/19/2022] Open
Abstract
Local tumor recurrence and distant tumor metastasis frequently occur after radiation therapy and result in the death of cancer patients. These problems are caused, at least in part, by a tumor-specific oxygen-poor microenvironment, hypoxia. Oxygen-deprivation is known to inhibit the chemical ionization of both intracellular macro-molecules and water, etc., and thus reduce the cytotoxic effects of radiation. Moreover, DNA damage produced by free radicals is known to be more repairable under hypoxia than normoxia. Hypoxia is also known to induce biological tumor radioresistance through the activation of a transcription factor, hypoxia-inducible factor 1 (HIF-1). Several potential strategies have been devised in radiation therapy to overcome these problems; however, they have not yet achieved a complete remission. It is essential to reveal the intratumoral localization and dynamics of hypoxic/HIF-1-active tumor cells during tumor growth and after radiation therapy, then exploit the information to develop innovative therapeutic strategies, and finally damage radioresistant cells. In this review, we overview problems caused by hypoxia/HIF-1-active cells in radiation therapy for cancer and introduce strategies to assess intratumoral hypoxia/HIF-1 activity.
Collapse
Affiliation(s)
- Chan Joo Yeom
- Group of Radiation and Tumor Biology, Career-Path Promotion Unit for Young Life Scientists, Kyoto University, Yoshida Konoe-cho, Sakyo-ku, Kyoto 606-8501, Japan; E-Mails: (C.J.Y.); (L.Z.); (Y.Z.)
| | - Lihua Zeng
- Group of Radiation and Tumor Biology, Career-Path Promotion Unit for Young Life Scientists, Kyoto University, Yoshida Konoe-cho, Sakyo-ku, Kyoto 606-8501, Japan; E-Mails: (C.J.Y.); (L.Z.); (Y.Z.)
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; E-Mail:
| | - Yuxi Zhu
- Group of Radiation and Tumor Biology, Career-Path Promotion Unit for Young Life Scientists, Kyoto University, Yoshida Konoe-cho, Sakyo-ku, Kyoto 606-8501, Japan; E-Mails: (C.J.Y.); (L.Z.); (Y.Z.)
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; E-Mail:
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; E-Mail:
| | - Hiroshi Harada
- Group of Radiation and Tumor Biology, Career-Path Promotion Unit for Young Life Scientists, Kyoto University, Yoshida Konoe-cho, Sakyo-ku, Kyoto 606-8501, Japan; E-Mails: (C.J.Y.); (L.Z.); (Y.Z.)
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +81-75-753-9301; Fax: +81-75-753-9281
| |
Collapse
|
7
|
Gulliksrud K, Øvrebø KM, Mathiesen B, Rofstad EK. Differentiation between hypoxic and non-hypoxic experimental tumors by dynamic contrast-enhanced magnetic resonance imaging. Radiother Oncol 2011; 98:360-4. [DOI: 10.1016/j.radonc.2010.12.016] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2010] [Revised: 12/15/2010] [Accepted: 12/23/2010] [Indexed: 10/18/2022]
|
8
|
Hokland SL, Nielsen T, Busk M, Horsman MR. Imaging tumour physiology and vasculature to predict and assess response to heat. Int J Hyperthermia 2010; 26:264-72. [PMID: 20388023 DOI: 10.3109/02656730903585982] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
The vascular supply of tumours and the tumour microenvironment both play an important role when tumours are treated with hyperthermia. Blood flow is one of the major vehicles by which heat is dissipated thus the vascular supply will influence the ability to heat the tumour. It also influences the type of microenvironment that exists within tumours, and it is now well-established that cells existing in areas of oxygen deficiency, nutrient deprivation and acidic conditions are more sensitive to the effect of hyperthermia. The vascular supply and microenvironment are also affected by hyperthermia. In general, mild heat temperatures transiently improve blood flow and oxygenation, while higher hyperthermia temperatures cause vascular collapse and so increase the adverse microenvironmental conditions. Being able to image these vascular and microenvironmental parameters both before and after heating will help in our ability to predict and assess response. Here we review the various techniques that can be applied to supply this information, especially using non-invasive imaging approaches.
Collapse
Affiliation(s)
- Steffen L Hokland
- Department of Experimental Clinical Oncology, Aarhus University Hospital NBG, Aarhus, Denmark
| | | | | | | |
Collapse
|
9
|
Raman V, Artemov D, Pathak AP, Winnard PT, McNutt S, Yudina A, Bogdanov A, Bhujwalla ZM. Characterizing vascular parameters in hypoxic regions: a combined magnetic resonance and optical imaging study of a human prostate cancer model. Cancer Res 2006; 66:9929-36. [PMID: 17047055 DOI: 10.1158/0008-5472.can-06-0886] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The integration of imaging technologies with the capabilities of genetic engineering has created novel opportunities for understanding and imaging cancer. Here, we have combined vascular magnetic resonance imaging (MRI) and optical imaging to understand the relationship between hypoxia and vascularization in a human prostate cancer model engineered to express enhanced green fluorescent protein (EGFP) under hypoxia. Characterization and validation of EGFP expression under hypoxic conditions was done in culture and in solid tumors in vivo. MRI measurements showed that vascular volume was significantly lower in fluorescing regions. These regions also frequently exhibited high permeability. These data were further supported by the detection of low vessel density in EGFP-positive regions, as determined by the distribution of intravascularly administered, fluorescence-labeled Lycopersicon esculentum lectin in frozen tumor sections. These observations are consistent with the possibility that regions of low vascular volumes are hypoxic, which induces increased expression of functionally active vascular endothelial growth factor, a potent vascular permeability factor.
Collapse
Affiliation(s)
- Venu Raman
- The Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Robinson SP, Griffiths JR. Current issues in the utility of 19F nuclear magnetic resonance methodologies for the assessment of tumour hypoxia. Philos Trans R Soc Lond B Biol Sci 2004; 359:987-96. [PMID: 15306411 PMCID: PMC1693379 DOI: 10.1098/rstb.2003.1376] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
It is now well established that uncontrolled proliferation of tumour cells together with the chaotic and poorly regulated blood supply of solid tumours result in tissue hypoxia, and that hypoxic regions of tumours are resistant to radiotherapy and chemotherapy. The development and application of non-invasive methods to rapidly determine the degree and extent of tumour hypoxia in an individual tumour would clearly enhance cancer treatment strategies. This review describes the current status of two (19)F nuclear magnetic resonance (NMR) methodologies that have been exploited to investigate tumour hypoxia, namely: (i) (19)F NMR oximetry following administration of perfluorocarbons, from which tumour p(O)(2) measurements can be made; and (ii) (19)F NMR measurements of the tumour retention of fluorinated 2-nitroimidazoles.
Collapse
Affiliation(s)
- Simon P Robinson
- Department of Basic Medical Sciences, St George's Hospital Medical School, Cranmer Terrace, London SW17 0RE, UK.
| | | |
Collapse
|
11
|
Zhao D, Ran S, Constantinescu A, Hahn EW, Mason RP. Tumor oxygen dynamics: correlation of in vivo MRI with histological findings. Neoplasia 2004; 5:308-18. [PMID: 14511402 PMCID: PMC1502418 DOI: 10.1016/s1476-5586(03)80024-6] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Tumor oxygenation has long been recognized as a significant factor influencing cancer therapy. We recently established a novel magnetic resonance in vivo approach to measuring regional tumor oxygen tension, FREDOM (Fluorocarbon Relaxometry Using Echo Planar Imaging for Dynamic Oxygen Mapping), using hexafluorobenzene (HFB) as the reporter molecule. We have now investigated oxygen dynamics in the two Dunning prostate R3327 rat tumor sublines, AT1 and H. FREDOM revealed considerable intratumoral heterogeneity in the distribution of pO(2) values in both sublines. The anaplastic faster-growing AT1 tumors were more hypoxic compared with the size-matched, well-differentiated, and slower-growing H tumors. Respiratory challenge with oxygen produced significant increases in mean and median pO(2) in all the H tumors (P<.001), but no response in half of the larger AT1 tumors (>3 cm(3)). Immunohistochemical studies using the hypoxia marker, pimonidazole, and the vascular endothelial cell marker, CD31, confirmed that the H tumors had more extensive vasculature and less hypoxia than the AT1 tumors. These results further validate the utilization of FREDOM to monitor tumor oxygenation and concur with the hypothesis that the level of hypoxia is related to tumor growth rate and poor vascularity.
Collapse
Affiliation(s)
- Dawen Zhao
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | | | | | | | | |
Collapse
|
12
|
Affiliation(s)
- Dawen Zhao
- Department of The University of Texas Southwestern Medicial Center at Dallas, 75390, USA
| | | | | |
Collapse
|
13
|
Merritt S, Bevilacqua F, Durkin AJ, Cuccia DJ, Lanning R, Tromberg BJ, Gulsen G, Yu H, Wang J, Nalcioglu O. Coregistration of diffuse optical spectroscopy and magnetic resonance imaging in a rat tumor model. APPLIED OPTICS 2003; 42:2951-9. [PMID: 12790444 DOI: 10.1364/ao.42.002951] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We report coregistration of near-infrared diffuse optical spectroscopy (DOS) and magnetic resonance imaging (MRI) for the study of animal model tumors. A combined broadband steady-state and frequency-domain apparatus was used to determine tissue oxyhemoglobin, deoxyhemoglobin, and water concentration locally in tumors. Simultaneous MRI coregistration provided structural (T2-weighted) and contrast-enhanced images of the tumor that were correlated with the optical measurements. By use of Monte Carlo simulations, the optically sampled volume was superimposed on the MR images, showing precisely which tissue structure was probed optically. DOS and MRI coregistration measurements were performed on seven rats over 20 days and were separated into three tumor tissue classifications: viable, edematous, and necrotic. A ratio of water concentration to total hemoglobin concentration, as measured optically, was performed for each tissue type and showed values for edematous tissue to be greater than viable tissue (1.2 +/- 0.49 M/microM versus 0.48 +/- 0.15 M/microM). Tissue hemoglobin oxygen saturation (StO2) also showed a large variation between tissue types: viable tissue had an optically measured StO2 value of 61 +/- 5%, whereas StO2 determined for necrotic tissue was 43 +/- 6%.
Collapse
Affiliation(s)
- Sean Merritt
- Laser Microbeam and Medical Program, Beckman Laser Institute, University of California Irvine, Irvine, California 92612, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Gulsen G, Yu H, Wang J, Nalcioglu O, Merritt S, Bevilacqua F, Durkin AJ, Cuccia DJ, Lanning R, Tromberg BJ. Congruent MRI and near-infrared spectroscopy for functional and structural imaging of tumors. Technol Cancer Res Treat 2002; 1:497-505. [PMID: 12625777 DOI: 10.1177/153303460200100610] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
We present a combined near-infrared diffuse optical spectroscopy (DOS) and Magnetic Resonance Imaging (MRI) system for the study of animal model tumors. A combined broadband steady-state and frequency domain optical spectroscopy apparatus was integrated with the MRI. The physiological properties of tissue rendered by MRI, including vascular volume fraction and water, were compared with chromophore concentrations as determined from the parameters obtained by optical measurements. DOS measurements provided oxy-hemoglobin, deoxy-hemoglobin, and water concentration locally in tumors. A method for co-registration of the information obtained by both modalities was developed. Using Monte Carlo simulations, the optically sampled volume was superimposed on the MR images, illustrating which tissue structure was probed optically. Finally, two optical contrast agents, indocyanine green (ICG) and methylene blue (MB), were employed and their kinetics were measured by DOS system from different locations on the tumor and compared with Gd-DTPA enhancement maps obtained from MRI.
Collapse
Affiliation(s)
- Gultekin Gulsen
- John Tu and Thomas Yuen Center for Functional Onco-Imaging, University of California Irvine, Irvine, California 92697, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Song Y, Constantinescu A, Mason RP. Dynamic breast tumor oximetry: the development of prognostic radiology. Technol Cancer Res Treat 2002; 1:471-8. [PMID: 12625774 DOI: 10.1177/153303460200100607] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
A novel pre clinical approach to evaluating tumor oxygen dynamics was recently introduced (Am. J. Clin. Oncol. 24, 462-466 (2001)). FREDOM (Fluorocarbon Relaxometry using Echo planar imaging for Dynamic Oxygen Mapping) allows maps of tumor pO(2) including 50 - 150 individual locations simultaneously to be produced with typical in plane resolution of 1.25 mm in 6.5 mins. The technique has been applied extensively in rat prostate tumors and is now demonstrated in the rat breast 13762NF adenocarcinoma. When anesthetized rats breathed 33% oxygen, mean baseline pO(2) was in the range 17 +/- 2 (se) torr to 74 +/- 4 torr with mean value for nine tumors 46 +/- 8 torr. However, small tumors (< 2.2 cm(3)) were significantly better oxygenated with mean pO(2) = 63 +/- 7 torr than large tumors (> 2.4 cm(3)) with mean pO(2) 24 +/- 5 torr (p < 0.002). Switching the inhaled gas to oxygen or carbogen produced a significant and rapid increase in mean pO(2) for both small and larger tumors (p < 0.05). Given the increasing evidence that tumor oxygenation is related to therapeutic outcome, we believe this approach to measuring tumor oxygen dynamics can be of value in predicting response to therapy, evaluating adjuvant interventions designed to modulate response to therapy, and in providing "Prognostic Radiology".
Collapse
Affiliation(s)
- Yulin Song
- Cancer Imaging Program, Department of Radiology, University of Texas, Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390, USA
| | | | | |
Collapse
|
16
|
Gulsen G, Muftuler LT, Nalcioglu O. A double end-cap birdcage RF coil for small animal whole body imaging. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2002; 156:309-312. [PMID: 12165267 DOI: 10.1006/jmre.2002.2547] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Proper design of a birdcage coil plays a very important role in obtaining high-resolution small animal magnetic resonance imaging. The RF field homogeneity and the coil filling factor directly affect the signal-to-noise ratio (S/N) and therefore limit the resolution. It has been shown that a conductive end-cap placed on one side of the coil can improve the RF field inhomogeneity near this area. This also contributes to an increase in the S/N by reducing the length of the RF coil. While this is true near the end-cap, the distal half of the coil still suffers from poor homogeneity and S/N. Consequently, such a shortfall may hinder small animal whole body imaging. In order to improve the coil performance for a larger imaging volume, we designed a new small animal birdcage RF coil by adding a detachable second end-cap to the open end. The performance of single end and double end RF coils was compared experimentally. The results indicate that the double end-cap can provide superior uniformity along the long axis of the coil. Furthermore, if one wishes to obtain the same homogeneity within a given volume, a double end-cap would have less than half of the length of the single end-cap coil leading to a superior S/N performance.
Collapse
Affiliation(s)
- Gultekin Gulsen
- John Tu and Thomas Yuen Center for Functional Onco-Imaging, University of California, Irvine, California, USA
| | | | | |
Collapse
|