Dogan L, Arslan GD. The analysis of tear meniscus parameters during daily soft contact lens wear using optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 2025; 263:171-179. [PMID: 39110197 PMCID: PMC11807020 DOI: 10.1007/s00417-024-06606-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 07/18/2024] [Accepted: 07/31/2024] [Indexed: 02/09/2025] Open
Abstract
PURPOSE To evaluate tear meniscus parameters in soft contact lens wearers (SCL) using optical coherence tomography (OCT) and ImageJ software. METHODS This prospective study included 50 soft contact lens wearers (group 1: 25 symptomatic SCL wearers (SCLW), group 2: 25 asymptomatic SCL wearers (ASCW)) and 25 healthy non-CL wearers (group 3 (NCLW)). SCLs were fitted on each eye of CL wearers, and the lower tear meniscus was imaged using OCT before CL insertion, immediately afterward, and reimaged 2, 5 and 10 h after insertion. Tear meniscus parameters, including tear meniscus height (TMH), depth (TMD), turbidity, and percentage area occupied by particles (PAOP) were measured in all groups. RESULTS Turbidity and PAOP measurements at baseline in SCLW were significantly higher than in other groups (p < 0.05). There was no significant difference between TMH, TMD, turbidity, and PAOP parameters calculated at baseline visit and two hours after SCL insertion in all groups (p > 0.05 for 2 comparisons). The symptomatic SCL users had a significant decrease in TMH and TMD in the fifth hour. The turbidity and PAOP measurements of SCLW and ASCW at the fifth and tenth hours were significantly higher than those of NCLW (p < 0.05). CONCLUSION TMD and height TMH decrease throughout the day in all participants; however, a significant decrease in these parameters was observed only in symptomatic SCL users at the fifth hour, at the earliest. As the duration of CL wear increases, turbidity and PAOP even in asymptomatic SCL wearers become significantly higher than those in healthy non-CL wearers. KEY MESSAGES What Is Known • Contact lens wear is associated with an increased risk of dry eye. • Tear volume decreases gradually during contact lens wear. What Is New • Tear meniscus turbidity and particle area occupied by particles (PAOP) were higher in symptomatic contact lens wearers and they increase gradually during contact lens wear. • Tear meniscus turbidity and PAOP may be measures of how well the tear film and meniscus are functioning in contact lens wearers.
Collapse
Affiliation(s)
- Levent Dogan
- Department of Ophthalmology, Tatvan State Hospital, Bitlis, Turkey.
| | | |
Collapse
|
2
|
Muñoz G, Millicovsky M, Cerrudo J, Peñalva A, Machtey M, Reta J, Torres R, Campana D, Zalazar M. Exploring tear viscosity with quartz crystal microbalance technology. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:075107. [PMID: 39023347 DOI: 10.1063/5.0207182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 07/03/2024] [Indexed: 07/20/2024]
Abstract
Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentially contributing to conditions such as dry eye syndrome. Despite their importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance (QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimal sample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eye drop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges. The average viscosity of healthy human tears was found to be 1.73 ± 0.61 cP, aligning with the typical range of 1-10 cP. Variability in the viscosities of eye drop can be attributed to differences in their chemical compositions. The QCM method offers benefits such as reduced sample consumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research with larger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eye syndrome, which is crucial for validating the device's clinical efficacy.
Collapse
Affiliation(s)
- G Muñoz
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - M Millicovsky
- Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática (CONICET-UNER), Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - J Cerrudo
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - A Peñalva
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - M Machtey
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - J Reta
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - R Torres
- ROMAT Creator Center, Colonia Avellaneda, Entre Ríos, Argentina and Investigador Independiente, Colaborador de la Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - D Campana
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
- Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática (CONICET-UNER), Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| | - M Zalazar
- Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
- Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática (CONICET-UNER), Ruta Prov. 11, Km 10, Oro Verde 3100, Entre Ríos, Argentina
| |
Collapse
|
3
|
Hsieh HH, Chang YA, Chan S, Lin ZQ, Lin CT, Hu FR, Hung KF, Sun YC. Characterizing the Robustness of Distinct Clinical Assessments in Identifying Dry Eye Condition of Animal Models. Curr Eye Res 2024; 49:565-573. [PMID: 38299568 DOI: 10.1080/02713683.2024.2310614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Accepted: 01/19/2024] [Indexed: 02/02/2024]
Abstract
PURPOSE The study aims to characterize the robustness of distinct clinical assessments in identifying the underlying conditions of dry eye disease (DED), with a specific emphasis on the involvement of conjunctival goblet cells. METHODS Seven rabbits receiving surgical removal of the lacrimal and Harderian glands were divided into two groups, one with ablation of conjunctival goblet cells by topical soaking of trichloroacetic acid (TCA) to the bulbar conjunctiva (n = 3) and one without (n = 4), and the conditions of DED were assessed weekly using Schirmer test, tear breakup time (TBUT), tear osmolarity, and National Eye Institute (NEI) fluorescein staining grading. After 8 weeks, the rabbits were sacrificed, and the eyes were enucleated for histopathological examination. RESULTS Histopathological analysis revealed corneal epithelial thinning in both groups. While TCA soaking significantly decreased the density of conjunctival goblet cells, DED rabbits without TCA also showed a partial reduction in goblet cell density, potentially attributable to dacryoadenectomy. Both groups showed significant decreases in Schirmer test and TBUT, as well as an increase in tear osmolarity. In DED rabbits with TCA soaking, tear osmolarity increased markedly, suggesting that tear osmolarity is highly sensitive to loss and/or dysfunction of conjunctival goblet cells. Fluorescein staining was gradually and similarly increased in both groups, suggesting that fluorescein staining may not reveal an early disruption of the tear film until the prolonged progression of DED. CONCLUSION The Schirmer test, TBUT, tear osmolarity, and NEI fluorescein grading are distinct, yet complementary, clinical assessments for the evaluation of DED. By performing these assessments in definitive DED rabbit models, both with and without ablation of conjunctival goblet cells, the role of these cells in the homeostasis of tear osmolarity is highlighted. Characterizing the robustness of these assessments in identifying the underlying conditions of DED will guide a more appropriate management for patients with DED.
Collapse
Affiliation(s)
- Hsiu-Hui Hsieh
- Department of Ophthalmology, Taipei Tzu Chi Hospital, The Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan
- School of Medicine, Tzu-Chi University, Hualien, Taiwan
| | - Yu-An Chang
- Institute of Veterinary Clinical Science, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan
| | - Szemin Chan
- Institute of Veterinary Clinical Science, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan
| | - Zhi-Qian Lin
- Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Chung-Tien Lin
- Institute of Veterinary Clinical Science, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan
| | - Fung-Rong Hu
- Department of Ophthalmology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Kai-Feng Hung
- Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan
- Department of Dentistry, School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Yi-Chen Sun
- Department of Ophthalmology, Taipei Tzu Chi Hospital, The Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan
- School of Medicine, Tzu-Chi University, Hualien, Taiwan
- Department of Ophthalmology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
4
|
Sharma S, Tyagi K, Dang S. Use of nanotechnology in dry eye syndrome. NANOTECHNOLOGY IN OPHTHALMOLOGY 2023:227-246. [DOI: 10.1016/b978-0-443-15264-1.00010-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
5
|
Sergio P, Giancarlo I, Matteo F, Maria DSC, Gianni P, Parrilla R, Valente P, Luca B. Analysis of tear film in cystinosis patients treated with topical viscous cysteamine hydrochloride (Cystadrop ®). Eur J Ophthalmol 2022; 32:3358-3362. [PMID: 35125035 PMCID: PMC9527349 DOI: 10.1177/11206721221078649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose The aim of this study was to evaluate in vivo the tear film
in infantile nephropathic cystinosis patients with corneal crystals treated
with topical viscous cysteamine hydrochloride (Cystadrops®). Methods Ten eyes of five patients with nephropathic cystinosis aged from 10 to 35
years were included in this study. The patients were under treatment with
viscous cysteamine hydrochloride formulation containing 3.8 mg/mL cysteamine
(vCH 0.55%, equivalent to 0.55% CH; Cystadrops®; Recordati rare
Diseases, Puteaux, France) to reduce corneal crystal density. Five age and
sex matched individuals were randomly selected as control group. Tear
osmolarity testing (TearLabTM) was performed to assess the
in vivo osmolarity of patients under treatment and
compared to control group values. Tear film break-up time (TBUT) and basic
tear secretion (Schirmer test) were also assessed. Results Mean tear osmolarity was 294.8 mOsms/L (±10.4), with a mean absolute
difference of 1.85 mOsms/L (±2.13) between the eyes. There was no
statistically significant difference between the osmolarity readings of
cystinosis and the control group (294.8 ± 10.4 vs 299.4 ± 6.2mOsm/L,
respectively; p = 0.39). The mean TBUT was 10.2 ± 0.83 s in the study group
versus 10 ± 0.7 s in controls (p = 0.62). The mean Schirmer test score was
9.2 ± 0.83 mm in the patients versus 10.2 ± 0.83 mm in the controls
(p = 0.14). Conclusions The TearLabTM osmolarity system test showed good reliability and
precision in repeated measurements. This is the first report using the
TearLab osmolarity system to assess tear film in patients with cystinosis
treated with vCH 0.55%. TearLabTM examination showed that the use
of vCH 0.55% drops does not determine alterations of the tear film
quality.
Collapse
Affiliation(s)
- Petroni Sergio
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Iarossi Giancarlo
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Federici Matteo
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | | | - Petrocelli Gianni
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Rosa Parrilla
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Paola Valente
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Buzzonetti Luca
- Ophthalmology Department, 9342Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| |
Collapse
|
6
|
Huang W, Huang L, Li W, Saglam MS, Tourmouzis K, Goldstein SM, Master A, Honkanen R, Rigas B. Once-Daily Topical Phosphosulindac Is Efficacious in the Treatment of Dry Eye Disease: Studies in Rabbit Models of Its Main Clinical Subtypes. J Ocul Pharmacol Ther 2021; 38:102-113. [PMID: 34964663 PMCID: PMC8817715 DOI: 10.1089/jop.2021.0050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Purpose: Dry eye disease (DED) is classified as aqueous deficient, evaporative, or mixed. We investigated the therapeutic effect of the novel anti-inflammatory drug phosphosulindac (PS) in rabbit models of DED encompassing its pathogenesis, and its transition to chronicity. Methods: We treated three rabbit models of DED with PS (hydrogel formulation) or vehicle topically applied 1 × /day. We induced aqueous-deficient DED (acute and chronic) by injecting Concanavalin A into lacrimal glands; evaporative DED by injecting into the upper eyelid inactivated Mycobacterium tuberculosis in complete Freund's adjuvant; and mixed DED through desiccative stress, induced by holding open the eye for 3 h. We determined corneal sensitivity, tear break-up time (TBUT), Schirmer's tear test (STT), tear osmolality, and fluorescein staining of the ocular surface. Results: PS reversed all abnormal DED parameters. In acute DED, PS dose dependently normalized corneal sensitivity and tear osmolality; and improved TBUT, STT, and fluorescein staining. PS normalized corneal sensitivity and improved all other parameters in chronic aqueous-deficient DED. In evaporative DED, PS normalized corneal sensitivity and improved TBUT and fluorescein staining (osmolality and STT were not significantly changed in this model). In the desiccative stress model, PS improved TBUT and fluorescein staining but had no effect on STT or tear osmolality. Conclusions: PS rapidly reversed almost all DED parameters in its three subtypes. The normalization of the suppressed corneal sensitivity suggests the possibility of marked symptomatic relief by PS. The hydrogel formulation allows once-daily dosing. PS merits further development as a potential treatment for DED.
Collapse
Affiliation(s)
- Wei Huang
- Department of Ophthalmology and Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA.,Department of Ophthalmology, 2nd Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Liqun Huang
- Department of Family, Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Wenyi Li
- Department of Family, Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA
| | - M Sait Saglam
- Department of Family, Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA
| | | | | | - Adam Master
- Department of Family, Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Robert Honkanen
- Department of Ophthalmology and Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Basil Rigas
- Department of Family, Population, Preventive Medicine, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA
| |
Collapse
|
7
|
Chen TY, Tseng CL, Lin CA, Lin HY, Venkatesan P, Lai PS. Effects of Eye Drops Containing Hyaluronic Acid-Nimesulide Conjugates in a Benzalkonium Chloride-Induced Experimental Dry Eye Rabbit Model. Pharmaceutics 2021; 13:1366. [PMID: 34575442 PMCID: PMC8469214 DOI: 10.3390/pharmaceutics13091366] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 08/19/2021] [Accepted: 08/26/2021] [Indexed: 12/22/2022] Open
Abstract
Dry eye syndrome (DES) is a common ocular disease worldwide. Currently, anti-inflammatory agents and immunosuppressive drugs, such as cyclosporine A, have been widely used to treat this chronic condition. However, the multifactorial etiology of DES, poor tolerance, low bioavailability, and prolonged treatment to response time have limited their usage. In this study, nimesulide, a cyclooxygenase (COX)-2 selective inhibitor, was conjugated with hyaluronic acid (HA), and the HA-nimesulide conjugates were expected to increase the solubility and biocompatibility for alleviating the DES in the benzalkonium chloride (BAC)-induced goblet cell-loss dry eye model. The therapeutic efficacy of HA-nimesulide was assessed using fluorescein staining, goblet cell density by conjunctival impression cytology, and histology and immunohistochemistry of corneal tissues. Compared to commercial artificial tears and Restasis®, the HA-nimesulide conjugates could promote goblet cell recovery and enhance the regeneration of the corneal epithelium. Importantly, immunofluorescent staining studies demonstrated that the HA-nimesulide conjugates could decrease the number of infiltrating CD11b-positive cells after two weeks of topical application. In the anti-inflammatory test, the HA-nimesulide conjugates could inhibit the production of pro-inflammatory cytokines and prostaglandin E2 (PGE2) in the lipopolysaccharide (LPS)-stimulated Raw 264.7 cell model. In conclusion, we demonstrated that HA-nimesulide conjugates had anti-inflammatory activity, and promoted goblet cell recovery and corneal epithelium regeneration when used as topical eye drops; accordingly, the HA-nimesulide conjugates could potentially be effective for the treatment of DES.
Collapse
Affiliation(s)
- Tzu-Yang Chen
- Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan; (T.-Y.C.); (P.V.)
| | - Ching-Li Tseng
- Graduate Institute of Biomedical Materials & Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan;
| | - Chih-An Lin
- Ph.D. Program of Tissue Engineering and Regenerative Medicine, National Chung Hsing University, Taichung 40227, Taiwan;
| | - Hua-Yang Lin
- Preclinical Development Research Department, Holy Stone Healthcare Co., Ltd., Taipei 11493, Taiwan;
| | - Parthiban Venkatesan
- Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan; (T.-Y.C.); (P.V.)
| | - Ping-Shan Lai
- Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan; (T.-Y.C.); (P.V.)
- Ph.D. Program of Tissue Engineering and Regenerative Medicine, National Chung Hsing University, Taichung 40227, Taiwan;
| |
Collapse
|
8
|
Cheng YH, Chang YF, Ko YC, Liu CJL. Development of a dual delivery of levofloxacin and prednisolone acetate via PLGA nanoparticles/ thermosensitive chitosan-based hydrogel for postoperative management: An in-vitro and ex-vivo study. Int J Biol Macromol 2021; 180:365-374. [PMID: 33676980 DOI: 10.1016/j.ijbiomac.2021.03.017] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 03/02/2021] [Accepted: 03/03/2021] [Indexed: 12/16/2022]
Abstract
Post-operative endophthalmitis (POE) is one of the most dreadful complications after intraocular surgery. For cataract surgery patients, both commercially available topical 0.5% levofloxacin and 1% prednisolone acetate (PA) ophthalmic solution require at least 3 to 4 times application daily. In this study, we develop a dual drug delivery system composed of the thermosensitive chitosan/gelatin-based hydrogel containing PA and levofloxacin-loaded nanoparticles (LNPs). LNPs with negative surface charge show the monodisperse (polydispersity index ~0.045), nanosize (~154.7 nm) and sphere-like structure. The optimal concentration of LNPs and PA to corneal epithelial cells was 5 μg/mL and 50 μg/mL, respectively. The developed dual drug delivery system (PAgel-LNPs) could gel at 34 °C within 63 s. The osmolarity of PAgel-LNPs was 301.2 ± 1.5 mOsm/L. PAgel-LNPs showed a sustained-release profile for 7 days. Post-treatment of PAgel-LNPs in TNF-α-damaged corneal epithelial cells could decrease the inflammation (inflammatory genes (TNF-α, IL-6, MMP-3 andMMP-9) and IL-6 production) and cell death. In ex-vivo rabbit model of S. aureus keratitis, the anti-inflammation and anti-bacterial property have been demonstrated. These results suggest that thermosensitive PAgel-LNPs may have the potential to use for the prevention of POE.
Collapse
Affiliation(s)
- Yung-Hsin Cheng
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.
| | - Yu-Fan Chang
- Department of Ophthalmology, Taipei Veterans General Hospital, Taipei, Taiwan; National Yang-Ming University School of Medicine, Faculty of Medicine, Taipei, Taiwan
| | - Yu-Chieh Ko
- Department of Ophthalmology, Taipei Veterans General Hospital, Taipei, Taiwan; National Yang-Ming University School of Medicine, Faculty of Medicine, Taipei, Taiwan
| | - Catherine Jui-Ling Liu
- Department of Ophthalmology, Taipei Veterans General Hospital, Taipei, Taiwan; National Yang-Ming University School of Medicine, Faculty of Medicine, Taipei, Taiwan.
| |
Collapse
|
9
|
Singh S, Basu S. The Human Lacrimal Gland: Historical Perspectives, Current Understanding, and Recent Advances. Curr Eye Res 2020; 45:1188-1198. [DOI: 10.1080/02713683.2020.1774065] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Swati Singh
- Centre for Ocular Regeneration (CORE), L V Prasad Eye Institute , Hyderabad, Telangana, India
| | - Sayan Basu
- Brien Holden Eye Research Centre (BHERC), L V Prasad Eye Institute , Hyderabad, Telangana, India
- The Cornea Institute, L V Prasad Eye Institute , Hyderabad, Telangana, India
| |
Collapse
|