1
|
Calcagno C, David JA, Motaal AG, Coolen BF, Beldman T, Corbin A, Kak A, Ramachandran S, Pruzan A, Sridhar A, Soler R, Faries CM, Fayad ZA, Mulder WJM, Strijkers GJ. Self-gated, dynamic contrast-enhanced magnetic resonance imaging with compressed-sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice. NMR IN BIOMEDICINE 2023; 36:e4823. [PMID: 36031706 PMCID: PMC10078106 DOI: 10.1002/nbm.4823] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 08/01/2022] [Accepted: 08/21/2022] [Indexed: 05/16/2023]
Abstract
High-risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self-gated, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe-/- atherosclerotic mice during natural disease progression. Twenty-four, 8-week-old, female Apoe-/- mice were divided into four groups (n = 6 each) and imaged with self-gated DCE-MRI at 4, 8, 12, and 16 weeks after high-fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high-fat diet and imaged longitudinally at the same time points. Aortic-root pseudo-concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash-in and washout slopes (b1 and b2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b2 , indicating contrast agent washout, was significantly higher in mice kept on an high-fat diet for longer periods of time (p = 0.03). Group comparison revealed significant differences between mice on a high-fat diet for 4 versus 16 weeks (p = 0.03). Macrophage density also significantly increased with diet duration (p = 0.009). Spearman correlation between b2 from DCE-MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE-MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single-slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.
Collapse
Affiliation(s)
- Claudia Calcagno
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - John A David
- Amsterdam University Medical Centers, Department of Medical Biochemistry, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands
| | - Abdallah G Motaal
- Siemens Healthineers, Cardiovascular Care Group, Advanced Therapies Business, Erlangen, Germany
| | - Bram F Coolen
- Amsterdam University Medical Centers, Department of Biomedical Engineering and Physics, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands
| | - Thijs Beldman
- Department of Internal Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
- Radboud Institute for Molecular Life Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Alexandra Corbin
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - Arnav Kak
- University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Sarayu Ramachandran
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - Alison Pruzan
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - Arthi Sridhar
- Department of Hematology/Oncology, UTHealth McGovern Medical School, Houston, TX, USA
| | - Raphael Soler
- CNRS, CRMBM, Marseille, France
- Department of Vascular and Endovascular Surgery, Hôpital Universitaire de la Timone, APHM, Marseille, France
| | - Christopher M Faries
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - Zahi A Fayad
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - Willem J M Mulder
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
- Department of Internal Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
- Radboud Institute for Molecular Life Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Gustav J Strijkers
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, USA
- Amsterdam University Medical Centers, Department of Biomedical Engineering and Physics, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
2
|
Fu Q, Liu DX, Zhang XY, Deng XB, Zheng CS. Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla. Neuroradiology 2020; 63:189-199. [PMID: 32794074 DOI: 10.1007/s00234-020-02512-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 08/02/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To investigate the clinical utility of pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography (PETRA-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA) to evaluate saccular unruptured intracranial aneurysms (UIAs). METHODS A total of 49 patients with 54 TOF-MRA-identified saccular UIAs were enrolled. The morphologic parameters, contrast-to-noise-ratios (CNRs), and sharpness of aneurysms were measured using PETRA-MRA and TOF-MRA. Two radiologists independently evaluated subjective image scores, focusing on aneurysm signal homogeneities and sharpness depictions using a 4-point scale: 4, excellent; 3, good; 2, poor; 1, not assessable. PETRA-MRA and TOF-MRA acoustic noises were measured. RESULTS All aneurysms were detected with PETRA-MRA. The morphologic parameters of 15 patients evaluated with PETRA-MRA were more closely correlated with those receiving computed tomography angiography over those receiving TOF-MRA. No significant differences between PETRA-MRA and TOF-MRA parameters were seen in the 54 UIAs (p > 0.10), excluding those with inflow angles (p < 0.05). In four patients with inflow angles on PETRA-MRA, the angles were more closely related to those of digital subtraction angiography than those of TOF-MRA. CNRs between TOF-MRA and PETRA-MRA were comparable (p = 0.068), and PETRA-MRA sharpness values and subjective image scores were significantly higher than those of TOF-MRA (p < 0.001). Inter-observer agreements were excellent for both PETRA-MRA and TOF-MRA (intraclass correlation coefficients were 0.90 and 0.97, respectively). The acoustic noise levels of PETRA-MRA were much lower than those of TOF-MRA (59 vs.73 dB, p < 0.01). CONCLUSIONS PETRA-MRA, with better visualization of aneurysms and lower acoustic noise levels than TOF-MRA, showed a superior diagnostic performance for depicting saccular UIAs.
Collapse
Affiliation(s)
- Qing Fu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China
| | - Ding-Xi Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China
| | - Xiao-Yong Zhang
- MR Collaborations, Siemens Healthcare Ltd, Shenzhen, 518000, People's Republic of China
| | - Xian-Bo Deng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China
| | - Chuan-Sheng Zheng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China. .,Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, People's Republic of China.
| |
Collapse
|
3
|
Chen H, Xie RM, Zhao L, Zhang XY, Zhao YK, Wang Z, Xie GX, Ma XH. Evaluation of left ventricular strain in patients with arrhythmia based on the 3T MR temporal parallel acquisition technique. Sci Rep 2020; 10:9342. [PMID: 32518330 PMCID: PMC7283215 DOI: 10.1038/s41598-020-66315-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 05/14/2020] [Indexed: 11/09/2022] Open
Abstract
Most of the current studies on myocardial strain are mainly applied in patients with sinus rhythm because the image quality of arrhythmias obtained with conventional scanning sequences does not meet diagnostic needs. Here, we intend to assess left ventricular (LV) global myocardial strain in patients with arrhythmias with 3 Tesla magnetic resonance (MR) and a new cine sequence. Thirty-three patients with arrhythmia and forty-eight subjects with sinus rhythm were enrolled in the study. LV myocardial thickness, cardiac function, myocardial strain and the apparent contrast-to-noise ratio (CNR) were all measured and compared using images generated by the real-time temporal parallel acquisition technique (TPAT) and the conventional cine sequence. In the arrhythmia group, the image quality of real-time TPAT was significantly better than that of the conventional cine sequence. In the arrhythmia group, the LV global peak radial strain and global peak circumferential strain values of real-time TPAT were significantly different from those of the conventional technique (radial strain, conventional: 20.27 ± 15.39 vs. TPAT: 24.14 ± 15.85, p = 0.007; circumferential strain, conventional:-12.06 ± 6.60 vs. TPAT: -13.71 ± 6.31, p = 0.015). There was no significant difference in global peak longitudinal strain between real-time TPAT and the conventional technique (-10.94 ± 4.66 vs. -10.70 ± 5.96, p = 0.771). There was no significant difference in the cardiac function parameters between the two techniques (p > 0.05), but there was a significant difference in 12 segments of the LV wall thickness between the two sequences (p < 0.05). In the sinus rhythm group, image quality using real-time TPAT was comparable to that using the conventional technique, and there was no significant difference in any of the indices (p > 0.05). Real-time TPAT is an effective method for detection of left ventricular myocardial deformation in patients with arrhythmia.
Collapse
Affiliation(s)
- Hui Chen
- Department of Radiology, Beijing Ditan Hospital, Capital Medical University, Beijing, 100015, China.,Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China
| | - Ru-Ming Xie
- Department of Radiology, Beijing Ditan Hospital, Capital Medical University, Beijing, 100015, China
| | - Lei Zhao
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Chaoyang District, Beijing, 100029, China
| | - Xiao-Yong Zhang
- MR Collaborations NE Asia, Siemens Healthcare, Shenzhen, 518000, China
| | - Yi-Ke Zhao
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Chaoyang District, Beijing, 100029, China
| | - Zheng Wang
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China
| | - Guo-Xi Xie
- Department of Biomedical Engineering, School of Basic Medical Science, Guangzhou Medical University, Guangzhou, 511416, China.
| | - Xiao-Hai Ma
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China.
| |
Collapse
|
4
|
Song L, Ma X, Zhao X, Zhao L, DeLano M, Fan Y, Wu B, Lu A, Tian J, He L. Validation of black blood late gadolinium enhancement (LGE) for evaluation of myocardial infarction in patients with or without pathological Q-wave on electrocardiogram (ECG). Cardiovasc Diagn Ther 2020; 10:124-134. [PMID: 32420092 DOI: 10.21037/cdt.2019.12.11] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Background The pathological Q-wave (QW) is an important indicator of infarcted myocardial volume indicating a worse prognosis compared to non-Q-wave (NQW) infarctions. Traditional classification divides infarcts into transmural and non-transmural based on QW and NQW. This view has been challenged by the advent of late gadolinium enhancement (LGE) MR imaging. Conventional LGE (Conv-LGE) detection of subendocardial MI is limited by bright blood pool. Dark Blood LGE imaging (DB-LGE) nulls the blood pool improving the conspicuity and accuracy of detection of subendocardial infarcts. We hypothesize that improved detection of subendocardial enhancement with DB-LGE will result in improved correlation of electrocardiogram (ECG) and extent of infarction. Methods Sixty-four clinically confirmed infarction patients were enrolled in this prospective study. All the participants underwent cardiac MR imaging including conv-LGE and DB-LGE. Twelve-lead ECG were performed on the same day. The patients were divided into QW and NQW groups by one experienced cardiologist. MI quantitation was by MI% (the ratio of MI volume to whole myocardial volume) and transmural grading, compared using paired t-test and Wilcoxon-test, respectively. The image quality obtained by Conv-LGE and DB-LGE were evaluated according to the signal intensity ratio (SIR) and contrast-to-noise ratio (CNR). Results Fifty-six subjects were enrolled in the final analysis [23 (41%) QW and 33 (59%) NQW infarcts]. For the QW cohort, both sequences classified infarcts as transmural in 21/23 (91%) subjects and subendocardial in 2/23 (9%). For the NQW cohort, both sequences classified infarcts as transmural in 16/33 (48%) subjects and subendocardial in 17/33 (52%). Using BB-LGE there were significant differences in detecting subendocardial infarcts in QW and NQW cohorts (Z=-5.85, P<0.001). The MI% of QW group was greater than in NQW group (24.2±10.3 vs.15.9±9.8, P=0.003). Compared to Conv-LGE, BB-LGE provided higher CNR and SIR between infarcted myocardium and blood pool (6.3±2.6 vs. 2.1±1.3, P<0.001; 5.4±1.9 vs. 1.3±0.2, P<0.001). BB-LGE detected more subendocardial infarcted segments in the QW group and NQW group (Z=-4.24, P<0.001; Z=-5.57, P<0.001). The larger MI% was displayed in BB-LGE than in Conv-LGE in both QW group and NQW group (24.2±10.3 vs. 22.6±10.3, P<0.001; 15.9±9.8 vs.14.6±9.6, P=0.001). Conclusions Compared to conventional LGE, DB-LGE can provide more accurate detection and characterization of infarction in terms of transmurality and subendocardial extent. This is important for evaluating QW and NQW MIs. Due to nulling the high signal of blood pool, DB-LGE can effectively improve the identification of subendocardial MI which may be missed on conventional LGE. Therefore, in both QW and NQW MIs, DB-LGE detects more subendocardial MIs and larger MI% is found. This may facilitate more accurate quantitative MR assessment of both QW and NQW MIs and further empower LGE volume as a predictive biomarker.
Collapse
Affiliation(s)
- Linsheng Song
- Department of Radiology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu 610072, China.,Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
| | - Xiaohai Ma
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
| | - Xinxiang Zhao
- Department of Radiology, The Second Affiliated Hospital of Kunming Medical University, Kunming 650101, China
| | - Lei Zhao
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
| | - Mark DeLano
- Division of Radiology and Biomedical Imaging, College of Human Medicine, Michigan State University, Advanced Radiology Services, PC, Spectrum Health, Grand Rapids, Michigan, USA
| | - Yang Fan
- GE Healthcare, Beijing 100176, China
| | - Bin Wu
- GE Healthcare, Beijing 100176, China
| | - Aijia Lu
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
| | - Jie Tian
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
| | - Liping He
- Department of Epidemiology and Biostatistics, School of Public Health, Kunming Medical University, Kunming 650500, China
| |
Collapse
|
5
|
Weisell J, Ruotsalainen AK, Laakso H, Ylä-Herttuala E, Näpänkangas J, Levonen AL, Liimatainen T, Rysä J. Characterizing valve dynamics in mice by high-resolution cine-MRI. NMR IN BIOMEDICINE 2019; 32:e4108. [PMID: 31112347 DOI: 10.1002/nbm.4108] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Revised: 04/01/2019] [Accepted: 04/02/2019] [Indexed: 06/09/2023]
Abstract
AIMS In calcific aortic valve disease (CAVD), progressive valvular sclerosis and calcification cause narrowing of the orifice and an impairment of the valve's function. We applied high-resolution cine-MRI to perform quantitative analysis of the dynamics of the aortic valve in a mice model of CAVD. METHODS AND RESULTS LDLr-/- ApoB100/100 mice were fed a Western diet (WD) or a standard diet (control) for 22 weeks. The mice were imaged in a 7 T horizontal MRI scanner, and aortic valve dynamics was examined by imaging the cross-section of the aorta at valve level using cine sequences. From these images, the area of the aortic valve orifice was determined during the heart cycle. MRI results were compared with echocardiographic and histopathologic results. The data revealed evidence of clear aortic valve dysfunction in WD mice as compared with control mice (interaction P < 0.001). MRI showed narrowing (14%, P < 0.05) of the orifice area, and this was also seen in histology (34%, P < 0.05), indicating more severe aortic stenosis after WD than in controls. Additionally, MRI revealed a reduction in the ejection fraction (EF) (-11%, P < 0.01), a result confirmed with echocardiography (-27%, P < 0.001) in mice fed with WD. EF detected by MRI and echocardiography also correlated strongly with the degree of stenosis assessed by histology. CONCLUSIONS Cine-MRI can be used for quantitative analysis of the aortic valve orifice over the cardiac cycle in mice. MRI showed the cusps clearly, and we were able to detect aortic valve dysfunction over time through the cardiac cycle.
Collapse
Affiliation(s)
- Jonna Weisell
- School of Pharmacy, University of Eastern Finland, Kuopio, Finland
| | - Anna-Kaisa Ruotsalainen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Hanne Laakso
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Elias Ylä-Herttuala
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Juha Näpänkangas
- Department of Pathology, University of Oulu, Oulu University Hospital, Oulu, Finland
| | - Anna-Liisa Levonen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Timo Liimatainen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
- Department of Diagnostic Radiology, University Hospital of Oulu, Oulu, Finland
| | - Jaana Rysä
- School of Pharmacy, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
6
|
Zhang X, Qiu B, Wei Z, Yan F, Shi C, Su S, Liu X, Ji JX, Xie G. Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system. PLoS One 2017; 12:e0189286. [PMID: 29216303 PMCID: PMC5720776 DOI: 10.1371/journal.pone.0189286] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Accepted: 11/23/2017] [Indexed: 12/25/2022] Open
Abstract
Purpose To develop and assess a three-dimensional (3D) self-gated technique for the evaluation of myocardial infarction (MI) in mouse model without the use of external electrocardiogram (ECG) trigger and respiratory motion sensor on a 3T clinical MR system. Methods A 3D T1-weighted GRE sequence with stack-of-stars sampling trajectories was developed and performed on six mice with MIs that were injected with a gadolinium-based contrast agent at a 3T clinical MR system. Respiratory and cardiac self-gating signals were derived from the Cartesian mapping of the k-space center along the partition encoding direction by bandpass filtering in image domain. The data were then realigned according to the predetermined self-gating signals for the following image reconstruction. In order to accelerate the data acquisition, image reconstruction was based on compressed sensing (CS) theory by exploiting temporal sparsity of the reconstructed images. In addition, images were also reconstructed from the same realigned data by conventional regridding method for demonstrating the advantageous of the proposed reconstruction method. Furthermore, the accuracy of detecting MI by the proposed method was assessed using histological analysis as the standard reference. Linear regression and Bland-Altman analysis were used to assess the agreement between the proposed method and the histological analysis. Results Compared to the conventional regridding method, the proposed CS method reconstructed images with much less streaking artifact, as well as a better contrast-to-noise ratio (CNR) between the blood and myocardium (4.1 ± 2.1 vs. 2.9 ± 1.1, p = 0.031). Linear regression and Bland-Altman analysis demonstrated that excellent correlation was obtained between infarct sizes derived from the proposed method and histology analysis. Conclusion A 3D T1-weighted self-gating technique for mouse cardiac imaging was developed, which has potential for accurately evaluating MIs in mice at 3T clinical MR system without the use of external ECG trigger and respiratory motion sensor.
Collapse
Affiliation(s)
- Xiaoyong Zhang
- Centers for Biomedical Engineering, University of Science and Technology of China, Hefei, China
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Bensheng Qiu
- Centers for Biomedical Engineering, University of Science and Technology of China, Hefei, China
- * E-mail: (GX); (BQ)
| | - Zijun Wei
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Fei Yan
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Caiyun Shi
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Shi Su
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jim X. Ji
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States of America
| | - Guoxi Xie
- The Sixth Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
- * E-mail: (GX); (BQ)
| |
Collapse
|
7
|
Wech T, Seiberlich N, Schindele A, Grau V, Diffley L, Gyngell ML, Borzì A, Köstler H, Schneider JE. Development of Real-Time Magnetic Resonance Imaging of Mouse Hearts at 9.4 Tesla--Simulations and First Application. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:912-920. [PMID: 26595913 PMCID: PMC4948122 DOI: 10.1109/tmi.2015.2501832] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A novel method for real-time magnetic resonance imaging for the assessment of cardiac function in mice at 9.4 T is proposed. The technique combines a highly undersampled radial gradient echo acquisition with an image reconstruction utilizing both parallel imaging and compressed sensing. Simulations on an in silico phantom were performed to determine the achievable acceleration factor and to optimize regularization parameters. Several parameters characterizing the quality of the reconstructed images (such as spatial and temporal image sharpness or compartment areas) were calculated for this purpose. Subsequently, double-gated segmented cine data as well as non-gated undersampled real-time data using only six projections per timeframe (temporal resolution ∼ 10 ms) were acquired in a mid-ventricular slice of four normal mouse hearts in vivo. The highly accelerated data sets were then subjected to the introduced reconstruction technique and results were validated against the fully sampled references. Functional parameters obtained from real-time and fully sampled data agreed well with a comparable accuracy for left-ventricular volumes and a slightly larger scatter for mass. This study introduces and validates a real-time cine-MRI technique, which significantly reduces scan time in preclinical cardiac functional imaging and has the potential to investigate mouse models with abnormal heart rhythm.
Collapse
Affiliation(s)
- Tobias Wech
- Department of Diagnostic and Interventional Radiology, University of Würzburg, Würzburg, Germany, and with the Comprehensive Heart Failure Center, University of Würzburg, Würzburg
| | - Nicole Seiberlich
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | | | - Vicente Grau
- Department of Engineering Science, University of Oxford, UK
| | - Leonie Diffley
- Radcliffe Department of Medicine, Division of Cardiovascular Medicine, University of Oxford, UK
| | | | - Alfio Borzì
- Institute of Mathematics, University of Würzburg, Würzburg, Germany
| | - Herbert Köstler
- Department of Diagnostic and Interventional Radiology, University of Würzburg, Würzburg, Germany, and with the Comprehensive Heart Failure Center, University of Würzburg, Würzburg
| | - Jürgen E. Schneider
- Radcliffe Department of Medicine, Division of Cardiovascular Medicine, University of Oxford, UK
| |
Collapse
|
8
|
Niendorf T, Pohlmann A, Reimann HM, Waiczies H, Peper E, Huelnhagen T, Seeliger E, Schreiber A, Kettritz R, Strobel K, Ku MC, Waiczies S. Advancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology. Front Pharmacol 2015; 6:255. [PMID: 26617515 PMCID: PMC4642111 DOI: 10.3389/fphar.2015.00255] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Accepted: 10/19/2015] [Indexed: 12/11/2022] Open
Abstract
Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR) for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF) coils in small animal MR as a means of boosting image quality (e.g., by supporting MR microscopy) and making data acquisition more efficient (e.g., by reducing measuring time); both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (bio)medical imaging, molecular medicine, and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (patho)physiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular, and renal disease will be discussed.
Collapse
Affiliation(s)
- Thoralf Niendorf
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
- German Centre for Cardiovascular ResearchBerlin, Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
| | - Henning M. Reimann
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
| | | | - Eva Peper
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
| | - Till Huelnhagen
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
| | - Erdmann Seeliger
- Center for Cardiovascular Research, Institute of Physiology, Charité—Universitätsmedizin BerlinBerlin, Germany
| | - Adrian Schreiber
- Clinic for Nephrology and Intensive Care Medicine, Charité Medical Faculty and Experimental and Clinical Research CenterBerlin, Germany
| | - Ralph Kettritz
- Clinic for Nephrology and Intensive Care Medicine, Charité Medical Faculty and Experimental and Clinical Research CenterBerlin, Germany
| | | | - Min-Chi Ku
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
| | - Sonia Waiczies
- Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz AssociationBerlin, Germany
| |
Collapse
|
9
|
Bakermans AJ, Abdurrachim D, Moonen RPM, Motaal AG, Prompers JJ, Strijkers GJ, Vandoorne K, Nicolay K. Small animal cardiovascular MR imaging and spectroscopy. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2015; 88-89:1-47. [PMID: 26282195 DOI: 10.1016/j.pnmrs.2015.03.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 03/09/2015] [Accepted: 03/09/2015] [Indexed: 06/04/2023]
Abstract
The use of MR imaging and spectroscopy for studying cardiovascular disease processes in small animals has increased tremendously over the past decade. This is the result of the remarkable advances in MR technologies and the increased availability of genetically modified mice. MR techniques provide a window on the entire timeline of cardiovascular disease development, ranging from subtle early changes in myocardial metabolism that often mark disease onset to severe myocardial dysfunction associated with end-stage heart failure. MR imaging and spectroscopy techniques play an important role in basic cardiovascular research and in cardiovascular disease diagnosis and therapy follow-up. This is due to the broad range of functional, structural and metabolic parameters that can be quantified by MR under in vivo conditions non-invasively. This review describes the spectrum of MR techniques that are employed in small animal cardiovascular disease research and how the technological challenges resulting from the small dimensions of heart and blood vessels as well as high heart and respiratory rates, particularly in mice, are tackled.
Collapse
Affiliation(s)
- Adrianus J Bakermans
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Desiree Abdurrachim
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rik P M Moonen
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Abdallah G Motaal
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Jeanine J Prompers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Gustav J Strijkers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Katrien Vandoorne
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Klaas Nicolay
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| |
Collapse
|
10
|
Buonincontri G, Methner C, Krieg T, Carpenter TA, Sawiak SJ. Functional assessment of the mouse heart by MRI with a 1-min acquisition. NMR IN BIOMEDICINE 2014; 27:733-737. [PMID: 24737267 DOI: 10.1002/nbm.3116] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2013] [Revised: 03/13/2014] [Accepted: 03/14/2014] [Indexed: 06/03/2023]
Abstract
In vivo assessment of heart function in mice is important for basic and translational research in cardiology. MRI is an accurate tool for the investigation of the anatomy and function in the preclinical setting; however, the long scan duration limits its usage. We aimed to reduce the acquisition time of cine MRI to 1 min. We employed spatiotemporal compressed sensing and parallel imaging to accelerate retrospectively gated cine MRI. We compared the functional parameters derived from full and undersampled data in Cartesian and radial MRI by means of Bland-Altman plots. We found that the scan time for the whole heart could be reduced to 2 min with Cartesian sampling and to 1 min with radial sampling. Despite a reduction in the signal-to-noise ratio, the accuracy in the estimation of left and right ventricular volumes was preserved for all tested subjects. This method can be used to perform accurate functional MRI examinations in mice for high-throughput phenotyping or translational studies.
Collapse
Affiliation(s)
- Guido Buonincontri
- Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK
| | | | | | | | | |
Collapse
|
11
|
Pennell DJ, Carpenter JP, Firmin DN, Kilner PJ, Mohiaddin RH, Prasad SK. Review of Journal of Cardiovascular Magnetic Resonance 2011. J Cardiovasc Magn Reson 2012; 14:78. [PMID: 23158097 PMCID: PMC3519784 DOI: 10.1186/1532-429x-14-78] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Accepted: 11/08/2012] [Indexed: 12/15/2022] Open
Abstract
There were 83 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2011, which is an 11% increase in the number of articles since 2010. The quality of the submissions continues to increase. The editors had been delighted with the 2010 JCMR Impact Factor of 4.33, although this fell modestly to 3.72 for 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, we remain very pleased with the progress of the journal's impact over the last 5 years. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors feel it is useful to summarize the papers for the readership into broad areas of interest or theme, which we feel would be useful, so that areas of interest from the previous year can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.
Collapse
Affiliation(s)
- Dudley J Pennell
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - John Paul Carpenter
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - David N Firmin
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Philip J Kilner
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Raad H Mohiaddin
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Sanjay K Prasad
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| |
Collapse
|
12
|
Greco A, Fiumara G, Gargiulo S, Gramanzini M, Brunetti A, Cuocolo A. High-resolution positron emission tomography/computed tomography imaging of the mouse heart. Exp Physiol 2012; 98:645-51. [PMID: 23118016 DOI: 10.1113/expphysiol.2012.068643] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Different animal models have been used to reproduce coronary heart disease, but in recent years mice have become the animals of choice, because of their short life cycle and the possibility of genetic manipulation. Various techniques are currently used for cardiovascular imaging in mice, including high-resolution ultrasound, X-ray computed tomography (CT), magnetic resonance imaging and nuclear medicine procedures. In particular, molecular imaging with cardiac positron emission tomography (PET) allows non-invasive evaluation of changes in myocardial perfusion, metabolism, apoptosis, inflammation and gene expression or measurement of changes in left ventricular functional parameters. With technological advances, dedicated small laboratory PET/CT imaging has emerged in cardiovascular research, providing in vivo a non-invasive, serial and quantitative assessment of left ventricular function, myocardial perfusion and metabolism at a molecular level. This non-invasive methodology might be useful in longitudinal studies to monitor cardiac biochemical parameters and might facilitate studies to assess the effect of different interventions after acute myocardial ischaemia.
Collapse
Affiliation(s)
- Adelaide Greco
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, Naples 80131, Italy
| | | | | | | | | | | |
Collapse
|
13
|
Coolen BF, Paulis LEM, Geelen T, Nicolay K, Strijkers GJ. Contrast-enhanced MRI of murine myocardial infarction - part II. NMR IN BIOMEDICINE 2012; 25:969-984. [PMID: 22311260 DOI: 10.1002/nbm.2767] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Revised: 11/07/2011] [Accepted: 11/29/2011] [Indexed: 05/31/2023]
Abstract
Mouse models are increasingly used to study the pathophysiology of myocardial infarction in vivo. In this area, MRI has become the gold standard imaging modality, because it combines high spatial and temporal resolution functional imaging with a large variety of methods to generate soft tissue contrast. In addition, (target-specific) MRI contrast agents can be employed to visualize different processes in the cascade of events following myocardial infarction. Here, the MRI sequence has a decisive role in the detection sensitivity of a contrast agent. However, a straightforward translation of clinically available protocols for human cardiac imaging to mice is not feasible, because of the small size of the mouse heart and its extremely high heart rate. This has stimulated intense research in the development of cardiac MRI protocols specifically tuned to the mouse with regard to timing parameters, acquisition strategies, and ECG- and respiratory-triggering methods to find an optimal trade-off between sensitivity, scan time, and image quality. In this review, a detailed analysis is given of the pros and cons of different mouse cardiac MR imaging methodologies and their application in contrast-enhanced MRI of myocardial infarction.
Collapse
Affiliation(s)
- Bram F Coolen
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, the Netherlands
| | | | | | | | | |
Collapse
|
14
|
Functional and morphological cardiac magnetic resonance imaging of mice using a cryogenic quadrature radiofrequency coil. PLoS One 2012; 7:e42383. [PMID: 22870323 PMCID: PMC3411643 DOI: 10.1371/journal.pone.0042383] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Accepted: 07/04/2012] [Indexed: 11/19/2022] Open
Abstract
Cardiac morphology and function assessment by magnetic resonance imaging is of increasing interest for a variety of mouse models in pre-clinical cardiac research, such as myocardial infarction models or myocardial injury/remodeling in genetically or pharmacologically induced hypertension. Signal-to-noise ratio (SNR) constraints, however, limit image quality and blood myocardium delineation, which crucially depend on high spatial resolution. Significant gains in SNR with a cryogenically cooled RF probe have been shown for mouse brain MRI, yet the potential of applying cryogenic RF coils for cardiac MR (CMR) in mice is, as of yet, untapped. This study examines the feasibility and potential benefits of CMR in mice employing a 400 MHz cryogenic RF surface coil, compared with a conventional mouse heart coil array operating at room temperature. The cryogenic RF coil affords SNR gains of 3.0 to 5.0 versus the conventional approach and hence enables an enhanced spatial resolution. This markedly improved image quality – by better deliniation of myocardial borders and enhanced depiction of papillary muscles and trabeculae – and facilitated a more accurate cardiac chamber quantification, due to reduced intraobserver variability. In summary the use of a cryogenically cooled RF probe represents a valuable means of enhancing the capabilities of CMR of mice.
Collapse
|
15
|
Nindl V, Maier R, Ratering D, De Giuli R, Züst R, Thiel V, Scandella E, Di Padova F, Kopf M, Rudin M, Rülicke T, Ludewig B. Cooperation of Th1 and Th17 cells determines transition from autoimmune myocarditis to dilated cardiomyopathy. Eur J Immunol 2012; 42:2311-21. [DOI: 10.1002/eji.201142209] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2011] [Revised: 04/27/2012] [Accepted: 05/24/2012] [Indexed: 01/22/2023]
Affiliation(s)
- Veronika Nindl
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| | - Reinhard Maier
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| | - David Ratering
- Institute for Biomedical Engineering; University and ETH Zurich; Zurich; Switzerland
| | - Rita De Giuli
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| | - Roland Züst
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| | - Volker Thiel
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| | - Elke Scandella
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| | - Franco Di Padova
- Novartis Institutes for Biomedical Research (NIBR); Basel; Switzerland
| | - Manfred Kopf
- Institute of Integrative Biology; ETH Zürich; Zürich; Switzerland
| | - Markus Rudin
- Institute for Biomedical Engineering; University and ETH Zurich; Zurich; Switzerland
| | - Thomas Rülicke
- Institute of Laboratory Animal Science; University of Veterinary Medicine; Vienna; Austria
| | - Burkhard Ludewig
- Institute of Immunobiology; Kantonal Hospital St. Gallen; St. Gallen; Switzerland
| |
Collapse
|
16
|
Greco A, Petretta MP, Larobina M, Gargiulo S, Panico M, Nekolla SG, Esposito G, Petretta M, Brunetti A, Cuocolo A. Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT. J Nucl Cardiol 2012; 19:492-9. [PMID: 22395780 DOI: 10.1007/s12350-012-9538-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2011] [Accepted: 02/18/2012] [Indexed: 12/26/2022]
Abstract
BACKGROUND This study assessed the reproducibility and accuracy of 2-deoxy-2[(18)F]fluoro-D-glucose ((18)F-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. METHODS AND RESULTS Mice were studied by (18)F-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% ± 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). CONCLUSIONS In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution (18)F-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.
Collapse
Affiliation(s)
- Adelaide Greco
- Department of Biomorphological and Functional Sciences, University Federico II, Naples, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Cardiovascular Magnetic Resonance of Myocardial Structure, Function, and Perfusion in Mouse and Rat Models. CURRENT CARDIOVASCULAR IMAGING REPORTS 2012. [DOI: 10.1007/s12410-012-9122-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
18
|
Wech T, Lemke A, Medway D, Stork LA, Lygate CA, Neubauer S, Köstler H, Schneider JE. Accelerating cine-MR imaging in mouse hearts using compressed sensing. J Magn Reson Imaging 2011; 34:1072-9. [PMID: 21932360 PMCID: PMC3261377 DOI: 10.1002/jmri.22718] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2011] [Accepted: 06/20/2011] [Indexed: 12/23/2022] Open
Abstract
Purpose To combine global cardiac function imaging with compressed sensing (CS) in order to reduce scan time and to validate this technique in normal mouse hearts and in a murine model of chronic myocardial infarction. Materials and Methods To determine the maximally achievable acceleration factor, fully acquired cine data, obtained in sham and chronically infarcted (MI) mouse hearts were 2–4-fold undersampled retrospectively, followed by CS reconstruction and blinded image segmentation. Subsequently, dedicated CS sampling schemes were implemented at a preclinical 9.4 T magnetic resonance imaging (MRI) system, and 2- and 3-fold undersampled cine data were acquired in normal mouse hearts with high temporal and spatial resolution. Results The retrospective analysis demonstrated that an undersampling factor of three is feasible without impairing accuracy of cardiac functional parameters. Dedicated CS sampling schemes applied prospectively to normal mouse hearts yielded comparable left-ventricular functional parameters, and intra- and interobserver variability between fully and 3-fold undersampled data. Conclusion This study introduces and validates an alternative means to speed up experimental cine-MRI without the need for expensive hardware. J. Magn. Reson. Imaging 2011. © 2011 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Tobias Wech
- Institute of Radiology, University of Würzburg, Würzburg, Germany
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Pennell DJ, Firmin DN, Kilner PJ, Manning WJ, Mohiaddin RH, Prasad SK. Review of journal of cardiovascular magnetic resonance 2010. J Cardiovasc Magn Reson 2011; 13:48. [PMID: 21914185 PMCID: PMC3182946 DOI: 10.1186/1532-429x-13-48] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2011] [Accepted: 09/13/2011] [Indexed: 12/15/2022] Open
Abstract
There were 75 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2010, which is a 34% increase in the number of articles since 2009. The quality of the submissions continues to increase, and the editors were delighted with the recent announcement of the JCMR Impact Factor of 4.33 which showed a 90% increase since last year. Our acceptance rate is approximately 30%, but has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. Last year for the first time, the Editors summarized the papers for the readership into broad areas of interest or theme, which we felt would be useful to practitioners of cardiovascular magnetic resonance (CMR) so that you could review areas of interest from the previous year in a single article in relation to each other and other recent JCMR articles 1. This experiment proved very popular with a very high rate of downloading, and therefore we intend to continue this review annually. The papers are presented in themes and comparison is drawn with previously published JCMR papers to identify the continuity of thought and publication in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.
Collapse
Affiliation(s)
- Dudley J Pennell
- CMR Unit Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - David N Firmin
- CMR Unit Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Philip J Kilner
- CMR Unit Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Warren J Manning
- Department of Medicine (Cardiovascular Division) and Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 USA
- Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 USA
| | - Raad H Mohiaddin
- CMR Unit Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Sanjay K Prasad
- CMR Unit Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| |
Collapse
|