1
|
Ren Z, Easley TO, Pineda FD, Guo X, Barber RF, Karczmar GS. Pharmacokinetic Analysis of Enhancement-Constrained Acceleration (ECA) reconstruction-based high temporal resolution breast DCE-MRI. PLoS One 2023; 18:e0286123. [PMID: 37319275 PMCID: PMC10270582 DOI: 10.1371/journal.pone.0286123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 05/09/2023] [Indexed: 06/17/2023] Open
Abstract
The high spatial and temporal resolution of dynamic contrast-enhanced MRI (DCE-MRI) can improve the diagnostic accuracy of breast cancer screening in patients who have dense breasts or are at high risk of breast cancer. However, the spatiotemporal resolution of DCE-MRI is limited by technical issues in clinical practice. Our earlier work demonstrated the use of image reconstruction with enhancement-constrained acceleration (ECA) to increase temporal resolution. ECA exploits the correlation in k-space between successive image acquisitions. Because of this correlation, and due to the very sparse enhancement at early times after contrast media injection, we can reconstruct images from highly under-sampled k-space data. Our previous results showed that ECA reconstruction at 0.25 seconds per image (4 Hz) can estimate bolus arrival time (BAT) and initial enhancement slope (iSlope) more accurately than a standard inverse fast Fourier transform (IFFT) when k-space data is sampled following a Cartesian based sampling trajectory with adequate signal-to-noise ratio (SNR). In this follow-up study, we investigated the effect of different Cartesian based sampling trajectories, SNRs and acceleration rates on the performance of ECA reconstruction in estimating contrast media kinetics in lesions (BAT, iSlope and Ktrans) and in arteries (Peak signal intensity of first pass, time to peak, and BAT). We further validated ECA reconstruction with a flow phantom experiment. Our results show that ECA reconstruction of k-space data acquired with 'Under-sampling with Repeated Advancing Phase' (UnWRAP) trajectories with an acceleration factor of 14, and temporal resolution of 0.5 s/image and high SNR (SNR ≥ 30 dB, noise standard deviation (std) < 3%) ensures minor errors (5% or 1 s error) in lesion kinetics. Medium SNR (SNR ≥ 20 dB, noise std ≤ 10%) was needed to accurately measure arterial enhancement kinetics. Our results also suggest that accelerated temporal resolution with ECA with 0.5 s/image is practical.
Collapse
Affiliation(s)
- Zhen Ren
- Department of Radiology, The University of Chicago, Chicago, Illinois, United States of America
| | - Ty O. Easley
- McKelvey School of Engineering, Washington University in St. Louis, St. Louis, Missouri, United States of America
| | - Federico D. Pineda
- Department of Radiology, The University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| | - Xiaodong Guo
- Department of Radiology, The University of Chicago, Chicago, Illinois, United States of America
| | - Rina F. Barber
- Department of Statistics, The University of Chicago, Chicago, Illinois, United States of America
| | - Gregory S. Karczmar
- Department of Radiology, The University of Chicago, Chicago, Illinois, United States of America
| |
Collapse
|
2
|
Ferrazzi G, Bassenge JP, Mayer J, Ruh A, Roujol S, Ittermann B, Schaeffter T, Cordero-Grande L, Schmitter S. Autocalibrated cardiac tissue phase mapping with multiband imaging and k-t acceleration. Magn Reson Med 2020; 84:2429-2441. [PMID: 32306471 DOI: 10.1002/mrm.28288] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 03/05/2020] [Accepted: 03/28/2020] [Indexed: 12/25/2022]
Abstract
PURPOSE To develop an autocalibrated multiband (MB) CAIPIRINHA acquisition scheme with in-plane k-t acceleration enabling multislice three-directional tissue phase mapping in one breath-hold. METHODS A k-t undersampling scheme was integrated into a time-resolved electrocardiographic-triggered autocalibrated MB gradient-echo sequence. The sequence was used to acquire data on 4 healthy volunteers with MB factors of two (MB2) and three (MB3), which were reconstructed using a joint reconstruction algorithm that tackles both k-t and MB acceleration. Forward simulations of the imaging process were used to tune the reconstruction model hyperparameters. Direct comparisons between MB and single-band tissue phase-mapping measurements were performed. RESULTS Simulations showed that the velocities could be accurately reproduced with MB2 k-t (average ± twice the SD of the RMS error of 0.08 ± 0.22 cm/s and velocity peak reduction of 1.03% ± 6.47% compared with fully sampled velocities), whereas acceptable results were obtained with MB3 k-t (RMS error of 0.13 ± 0.58 cm/s and peak reduction of 2.21% ± 13.45%). When applied to tissue phase-mapping data, the proposed technique allowed three-directional velocity encoding to be simultaneously acquired at two/three slices in a single breath-hold of 18 heartbeats. No statistically significant differences were detected between MB2/MB3 k-t and single-band k-t motion traces averaged over the myocardium. Regional differences were found, however, when using the American Heart Association model for segmentation. CONCLUSION An autocalibrated MB k-t acquisition/reconstruction framework is presented that allows three-directional velocity encoding of the myocardial velocities at multiple slices in one breath-hold.
Collapse
Affiliation(s)
- Giulio Ferrazzi
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Jean Pierre Bassenge
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Johannes Mayer
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Alexander Ruh
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Sébastien Roujol
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Tobias Schaeffter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- FG Medizintechnik, Technische Universität Berlin, Berlin, Germany
| | - Lucilio Cordero-Grande
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid & CIBER-BBN, Madrid, Spain
- Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| |
Collapse
|
3
|
Automated Description of Regional Left Ventricular Motion in Patients With Cardiac Amyloidosis: A Quantitative Study Using Heart Deformation Analysis. AJR Am J Roentgenol 2017; 209:W57-W63. [PMID: 28537770 DOI: 10.2214/ajr.16.16982] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
OBJECTIVE The purpose of this article is to test the hypothesis that heart deformation analysis can automatically quantify regional myocardial motion patterns in patients with cardiac amyloidosis. SUBJECTS AND METHODS Eleven patients with cardiac amyloidosis and 11 healthy control subjects were recruited to undergo cardiac MRI. Cine images were analyzed using heart deformation analysis and feature tracking. Heart deformation analysis-derived myocardial motion indexes in radial and circumferential directions, including radial and circumferential displacement, radial and circumferential velocity, radial and circumferential strain, and radial and circumferential strain rate, were compared between the two groups. RESULTS ) than did healthy control subjects. Heart deformation analysis-derived indexes correlated with feature tracking-derived indexes (r = 0.411 and 0.552). CONCLUSION Heart deformation analysis is able to automatically quantify regional myocardial motion in patients with cardiac amyloidosis without the need for operator interaction.
Collapse
|
4
|
Arai TJ, Nofiele J, Madhuranthakam AJ, Yuan Q, Pedrosa I, Chopra R, Sawant A. Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy. Med Phys 2017; 43:2807-2820. [PMID: 27277029 DOI: 10.1118/1.4948684] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of "true" information due to greater reliance on a priori information. METHODS Lung tumor motion trajectories in the superior-inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. RESULTS In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3-0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. CONCLUSIONS The authors' initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.
Collapse
Affiliation(s)
- Tatsuya J Arai
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Joris Nofiele
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Qing Yuan
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Ivan Pedrosa
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Amit Sawant
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390; Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390; and Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland, 21201
| |
Collapse
|
5
|
Lin K, Meng L, Collins JD, Chowdhary V, Markl M, Carr JC. Heart deformation analysis: the distribution of regional myocardial motion patterns at left ventricle. Int J Cardiovasc Imaging 2016; 33:351-359. [PMID: 27783187 DOI: 10.1007/s10554-016-1005-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2016] [Accepted: 10/20/2016] [Indexed: 12/14/2022]
Abstract
The aim of the present study was to test the hypothesis that heart deformation analysis (HDA) is able to discriminate regional myocardial motion patterns on the left ventricle (LV). Totally 21 healthy volunteers (15 men and 6 women) without documented cardiovascular diseases were recruited. Cine MRI was performed on those subjects at four-chamber, two-chamber, and short-axis views. The variations of segmental myocardial motion indices of the LV, which were measured with the HDA tool, were investigated. Regional displacement, velocity, strain and strain rate were compared between lateral wall and septal wall using t tests. There are significant variations (CoV = 18.0-72.4%) of myocardial motion indices (average over 21 subjects) among 16 myocardial segments. There are significant differences (p < 0.05) between displacement, velocity, strain and strain rate measured at lateral and septal areas of the LV. In conclusion, HDA is able to present different regional LV motion patterns from multiple aspects in healthy volunteers.
Collapse
Affiliation(s)
- Kai Lin
- Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611, USA.
| | - Leng Meng
- Department of Radiology, Anzhen Hospital, Capital Medical University, Anzhen Li, Chaoyang District, Beijing, 100029, China
| | - Jeremy D Collins
- Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611, USA
| | - Varun Chowdhary
- Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611, USA
| | - James C Carr
- Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611, USA
| |
Collapse
|
6
|
Paul J, Wundrak S, Hombach V, Rottbauer W, Rasche V. On the influence of respiratory motion in radial tissue phase mapping cardiac MRI. J Magn Reson Imaging 2016; 44:1218-1228. [PMID: 27086896 DOI: 10.1002/jmri.25286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 03/31/2016] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To investigate the impact of respiratory motion on radial tissue phase mapping (TPM) measurements, and to improve image quality and scan efficiency without compromising velocity fidelity by increasing the respiratory acceptance window with and without motion correction. MATERIALS AND METHODS A radial golden angle TPM sequence was measured in 10 healthy volunteers in three short axis slices at 3T. Ungated ( CFREE), self-gated with a single acceptance window ( CREF), motion-corrected averaging using all ( CMCall), or selected ( CMC) data reconstructions were compared by means of various image quality measures and resulting velocities. RESULTS Using all data ( CFREE) resulted in significantly higher perceived signal-to-noise ratio (SNR) (P < 0.001), but significantly reduced sharpness (P < 0.001) and contrast (P = 0.02), when compared to CREF. Coefficient of variation (CV) and perceived sharpness were not significantly different (P > 0.05). With motion-correction, perceived sharpness could be significantly improved ( CMC: P = 0.002; CMCall: P = 0.002) in comparison to CFREE. Velocity peaks of CFREE were significantly reduced compared to CREF (all peaks: P < 0.001; except the longitudinal "E" peak: P = 0.03). The peak velocities in CMC and CMCall were not significantly different from CREF (all peaks: P > 0.08; except longitudinal "E"/"A" peaks: P > 0.01). CONCLUSION Free-breathing reconstruction results in good perceived image sharpness and velocity information with slightly, but significantly, reduced peak velocities. For achieving velocities and image quality comparable to data from a single acceptance window, but higher gating efficiency, selected motion-corrected TPM (CMC) can be applied. J. Magn. Reson. Imaging 2016;44:1218-1228.
Collapse
Affiliation(s)
- Jan Paul
- Department of Internal Medicine II, University Hospital of Ulm, Germany.
| | - Stefan Wundrak
- Department of Internal Medicine II, University Hospital of Ulm, Germany
| | - Vinzenz Hombach
- Department of Internal Medicine II, University Hospital of Ulm, Germany
| | | | - Volker Rasche
- Department of Internal Medicine II, University Hospital of Ulm, Germany
| |
Collapse
|
7
|
Paul J, Wundrak S, Bernhardt P, Rottbauer W, Neumann H, Rasche V. Self‐gated tissue phase mapping using golden angle radial sparse SENSE. Magn Reson Med 2015; 75:789-800. [DOI: 10.1002/mrm.25669] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Revised: 01/13/2015] [Accepted: 02/02/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Jan Paul
- Department of Internal Medicine IIUniversity Hospital of Ulm Germany
| | - Stefan Wundrak
- Department of Internal Medicine IIUniversity Hospital of Ulm Germany
| | - Peter Bernhardt
- Department of Internal Medicine IIUniversity Hospital of Ulm Germany
| | | | - Heiko Neumann
- Institute of Neural Information Processing, University of Ulm Germany
| | - Volker Rasche
- Department of Internal Medicine IIUniversity Hospital of Ulm Germany
| |
Collapse
|
8
|
Zhu X, Schwab F, Marcus R, Hetterich H, Theisen D, Kramer H, Notohamiprodjo M, Schlett CL, Nikolaou K, Reiser MF, Bamberg F. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3T. Eur J Radiol 2015; 84:849-55. [PMID: 25791016 DOI: 10.1016/j.ejrad.2015.02.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2014] [Revised: 01/18/2015] [Accepted: 02/15/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. MATERIALS AND METHODS In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. RESULTS Among 25 subjects, 24 were included in the analysis (mean age: 50.5±21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICC<0.40). Similarly, RT cines significantly underestimated peak ejection and filling rates (>103.2±178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (p<0.05). CONCLUSIONS RT cine MRI at 3T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates.
Collapse
Affiliation(s)
- Xiaomei Zhu
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, 300, Guangzhou Road, 210029 Nanjing, Jiangsu, China.
| | - Felix Schwab
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany.
| | - Roy Marcus
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany.
| | - Holger Hetterich
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany.
| | - Daniel Theisen
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany.
| | - Harald Kramer
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany.
| | - Mike Notohamiprodjo
- Department of Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany.
| | - Christopher L Schlett
- Department of Radiology, University of Heidelberg, Neuenheimer Feld 110, 69120 Heidelberg, Germany.
| | - Konstantin Nikolaou
- Department of Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany.
| | - Maximilian F Reiser
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany.
| | - Fabian Bamberg
- Institute of Clinical Radiology, Ludwig-Maximilians-University Hospital, Marchioninistrasse 15, 81377 Munich, Germany; Department of Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany.
| |
Collapse
|
9
|
Pokharel P, Yoon AJ, Bella JN. Noninvasive measurement and clinical relevance of myocardial twist and torsion. Expert Rev Cardiovasc Ther 2014; 12:1305-15. [DOI: 10.1586/14779072.2014.970179] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
10
|
Simpson R, Keegan J, Gatehouse P, Hansen M, Firmin D. Spiral tissue phase velocity mapping in a breath-hold with non-cartesian SENSE. Magn Reson Med 2014; 72:659-68. [PMID: 24123135 PMCID: PMC3979503 DOI: 10.1002/mrm.24971] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Revised: 08/23/2013] [Accepted: 09/05/2013] [Indexed: 11/07/2022]
Abstract
PURPOSE Tissue phase velocity mapping (TPVM) is capable of reproducibly measuring regional myocardial velocities. However acquisition durations of navigator gated techniques are long and unpredictable while current breath-hold techniques have low temporal resolution. This study presents a spiral TPVM technique which acquires high resolution data within a clinically acceptable breath-hold duration. METHODS Ten healthy volunteers are scanned using a spiral sequence with temporal resolution of 24 ms and spatial resolution of 1.7 × 1.7 mm. Retrospective cardiac gating is used to acquire data over the entire cardiac cycle. The acquisition is accelerated by factors of 2 and 3 by use of non-Cartesian SENSE implemented on the Gadgetron GPU system resulting in breath-holds of 17 and 13 heartbeats, respectively. Systolic, early diastolic, and atrial systolic global and regional longitudinal, circumferential, and radial velocities are determined. RESULTS Global and regional velocities agree well with those previously reported. The two acceleration factors show no significant differences for any quantitative parameter and the results also closely match previously acquired higher spatial resolution navigator-gated data in the same subjects. CONCLUSION By using spiral trajectories and non-Cartesian SENSE high resolution, TPVM data can be acquired within a clinically acceptable breath-hold.
Collapse
Affiliation(s)
- R. Simpson
- NIHR Royal Brompton Cardiovascular Biomedical Research Unit, London, UK
- Imperial College, London
| | - J. Keegan
- NIHR Royal Brompton Cardiovascular Biomedical Research Unit, London, UK
- Imperial College, London
| | - P. Gatehouse
- NIHR Royal Brompton Cardiovascular Biomedical Research Unit, London, UK
| | - M. Hansen
- National Heart, Lung and Blood Institute, NIH, Bethesda, Maryland, USA
| | - D. Firmin
- NIHR Royal Brompton Cardiovascular Biomedical Research Unit, London, UK
- Imperial College, London
| |
Collapse
|
11
|
Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography. MAGMA (NEW YORK, N.Y.) 2013; 27:211-8. [PMID: 24013857 DOI: 10.1007/s10334-013-0405-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2013] [Revised: 08/16/2013] [Accepted: 08/27/2013] [Indexed: 10/26/2022]
Abstract
OBJECT Phase contrast imaging is widely used to measure blood velocity. However tissue Doppler imaging (TDI) echocardiography is the reference for myocardial velocity assessment. This study aims at validating the ability of phase contrast (PC) sequences to correctly assess myocardial velocities and to compare these velocities to TDI. The phase contrast sequence was performed with breath-hold parameters and with parameters tuned to increase temporal resolution in free breathing. MATERIALS AND METHODS Left and Right auriculo-ventricular annuluses longitudinal velocities were recorded on six healthy volunteers with different temporal resolutions (TDI: 5 ms, breath-hold PC: 94 ms and free-breathing PC: 19 ms). Free-breathing PC was obtained by averaging of three excitations. Amplitudes of four standard echocardiographic and clinically relevant myocardial longitudinal velocity waves were compared: Early filling and auricular, systolic and isovolumic contractions. RESULTS Isovolumic contraction waves were only visible with free-breathing PC and TDI. The differences with the reference TDI wave velocities were lower (p = 0.02) for free-breathing PC (19.2 ± 2.6%) than for breath-hold PC (28.1 ± 2.9%). These differences for free-breathing PC were close to (p = 0.21) the coefficient of variation of the measurements provided by TDI (14.8 ± 1.2%). CONCLUSION Myocardial longitudinal peak velocities can be assessed with a PC sequence tuned to optimize temporal resolution.
Collapse
|
12
|
Pennell DJ, Baksi AJ, Carpenter JP, Firmin DN, Kilner PJ, Mohiaddin RH, Prasad SK. Review of Journal of Cardiovascular Magnetic Resonance 2012. J Cardiovasc Magn Reson 2013; 15:76. [PMID: 24006874 PMCID: PMC3847143 DOI: 10.1186/1532-429x-15-76] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2013] [Accepted: 08/22/2013] [Indexed: 02/07/2023] Open
Abstract
There were 90 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2012, which is an 8% increase in the number of articles since 2011. The quality of the submissions continues to increase. The editors are delighted to report that the 2011 JCMR Impact Factor (which is published in June 2012) has risen to 4.44, up from 3.72 for 2010 (as published in June 2011), a 20% increase. The 2011 impact factor means that the JCMR papers that were published in 2009 and 2010 were cited on average 4.44 times in 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.
Collapse
Affiliation(s)
- Dudley J Pennell
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| | - A John Baksi
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| | - John Paul Carpenter
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| | - David N Firmin
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| | - Philip J Kilner
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| | - Raad H Mohiaddin
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| | - Sanjay K Prasad
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Imperial College, London, UK
| |
Collapse
|
13
|
Pennell DJ, Carpenter JP, Firmin DN, Kilner PJ, Mohiaddin RH, Prasad SK. Review of Journal of Cardiovascular Magnetic Resonance 2011. J Cardiovasc Magn Reson 2012; 14:78. [PMID: 23158097 PMCID: PMC3519784 DOI: 10.1186/1532-429x-14-78] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Accepted: 11/08/2012] [Indexed: 12/15/2022] Open
Abstract
There were 83 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2011, which is an 11% increase in the number of articles since 2010. The quality of the submissions continues to increase. The editors had been delighted with the 2010 JCMR Impact Factor of 4.33, although this fell modestly to 3.72 for 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, we remain very pleased with the progress of the journal's impact over the last 5 years. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors feel it is useful to summarize the papers for the readership into broad areas of interest or theme, which we feel would be useful, so that areas of interest from the previous year can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.
Collapse
Affiliation(s)
- Dudley J Pennell
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - John Paul Carpenter
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - David N Firmin
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Philip J Kilner
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Raad H Mohiaddin
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| | - Sanjay K Prasad
- CMR Unit Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, Exhibition Road, London, SW7 2AZ, UK
| |
Collapse
|
14
|
Lutz A, Paul J, Bornstedt A, Nienhaus GU, Etyngier P, Bernhardt P, Rottbauer W, Rasche V. Volumetric motion quantification by 3D tissue phase mapped CMR. J Cardiovasc Magn Reson 2012; 14:74. [PMID: 23101880 PMCID: PMC3514160 DOI: 10.1186/1532-429x-14-74] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Accepted: 09/27/2012] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND The objective of this study was the quantification of myocardial motion from 3D tissue phase mapped (TPM) CMR. Recent work on myocardial motion quantification by TPM has been focussed on multi-slice 2D acquisitions thus excluding motion information from large regions of the left ventricle. Volumetric motion assessment appears an important next step towards the understanding of the volumetric myocardial motion and hence may further improve diagnosis and treatments in patients with myocardial motion abnormalities. METHODS Volumetric motion quantification of the complete left ventricle was performed in 12 healthy volunteers and two patients applying a black-blood 3D TPM sequence. The resulting motion field was analysed regarding motion pattern differences between apical and basal locations as well as for asynchronous motion pattern between different myocardial segments in one or more slices. Motion quantification included velocity, torsion, rotation angle and strain derived parameters. RESULTS All investigated motion quantification parameters could be calculated from the 3D-TPM data. Parameters quantifying hypokinetic or asynchronous motion demonstrated differences between motion impaired and healthy myocardium. CONCLUSIONS 3D-TPM enables the gapless volumetric quantification of motion abnormalities of the left ventricle, which can be applied in future application as additional information to provide a more detailed analysis of the left ventricular function.
Collapse
Affiliation(s)
- Anja Lutz
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Dusseldorf, Germany
| | - Jan Paul
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
| | - Axel Bornstedt
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
| | - G Ulrich Nienhaus
- Institute of Applied Physics and Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | | | - Peter Bernhardt
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
| | - Wolfgang Rottbauer
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
| | - Volker Rasche
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
| |
Collapse
|
15
|
van Ooij P, Guédon A, Marquering HA, Schneiders JJ, Majoie CB, van Bavel E, Nederveen AJ. k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2012; 26:261-70. [PMID: 22955942 DOI: 10.1007/s10334-012-0336-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Revised: 07/20/2012] [Accepted: 08/06/2012] [Indexed: 10/27/2022]
Abstract
OBJECTIVE The objective of this study was to investigate the performance of k-t BLAST (Broad-use Linear Acquisition Speed-up Technique) accelerated time-resolved 3D PC-MRI compared to SENSE (SENSitivity Encoding) acceleration in an in vitro and in vivo intracranial aneurysm. MATERIALS AND METHODS Non-accelerated, SENSE and k-t BLAST accelerated time-resolved 3D PC-MRI measurements were performed in vivo and in vitro. We analysed the consequences of various temporal resolutions in vitro. RESULTS Both in vitro and in vivo measurements showed that the main effect of k-t BLAST was underestimation of velocity during systole. In the phantom, temporal blurring decreased with increasing temporal resolution. Quantification of the differences between the non-accelerated and accelerated measurements confirmed that in systole SENSE performed better than k-t BLAST in terms of mean velocity magnitude. In both in vitro and in vivo measurements, k-t BLAST had higher SNR compared to SENSE. Qualitative comparison between measurements showed good similarity. CONCLUSION Comparison with SENSE revealed temporal blurring effects in k-t BLAST accelerated measurements.
Collapse
Affiliation(s)
- Pim van Ooij
- Department of Radiology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
16
|
Lutz A, Bornstedt A, Manzke R, Etyngier P, Nienhaus GU, Rottbauer W, Rasche V. Acceleration of tissue phase mapping with sensitivity encoding at 3T. J Cardiovasc Magn Reson 2011; 13:59. [PMID: 21992267 PMCID: PMC3217863 DOI: 10.1186/1532-429x-13-59] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2011] [Accepted: 10/12/2011] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The objective of this study was to investigate the impact of sensitivity encoding on the quantitative assessment of cardiac motion in black blood cine tissue phase mapping (TPM) sequences. Up to now whole volume coverage of the heart is still limited by the long acquisition times. Therefore, a significant increase in imaging speed without deterioration of quantitative motion information is indispensable. METHODS 20 volunteers were enrolled in this study. Each volunteer underwent myocardial short-axis TPM scans with different SENSE acceleration factors. The influence of SENSE acceleration on the measured motion curves was investigated. RESULTS It is demonstrated that all TPM sequences with SENSE acceleration have only minimum influence on the motion curves. Even with a SENSE factor of four, the decrease in the amplitude of the motion curve was less than 3%. No significant difference was observed for the global correlation coefficient and deviation between the motion curves obtained by the reproducibility and the SENSE accelerated measurements. CONCLUSIONS It is feasible to accelerate myocardial TPM measurements with SENSE factors up to 4 without losing substantial information of the motion pattern.
Collapse
Affiliation(s)
- Anja Lutz
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| | - Axel Bornstedt
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| | - Robert Manzke
- Philips Research North America, Briarcliff Manor, USA
| | | | | | - Wolfgang Rottbauer
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| | - Volker Rasche
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| |
Collapse
|