1
|
Kaushik N, Sharma P, Himori N, Matsumoto T, Miya T, Nakazawa T. Mobile infrared slit-light scanner for rapid eye disease screening. J Med Imaging (Bellingham) 2024; 11:026003. [PMID: 38606184 PMCID: PMC11003872 DOI: 10.1117/1.jmi.11.2.026003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 03/14/2024] [Accepted: 03/28/2024] [Indexed: 04/13/2024] Open
Abstract
Purpose Timely detection and treatment of visual impairments and age-related eye diseases are essential for maintaining a longer, healthier life. However, the shortage of appropriate medical equipment often impedes early detection. We have developed a portable self-imaging slit-light device utilizing NIR light and a scanning mirror. The objective of our study is to assess the accuracy and compare the performance of our device with conventional nonportable slit-lamp microscopes and anterior segment optical coherence tomography (AS-OCT) for screening and remotely diagnosing eye diseases, such as cataracts and glaucoma, outside of an eye clinic. Approach The NIR light provides an advantage as measurements are nonmydriatic and less traumatic for patients. A cross-sectional study involving Japanese adults was conducted. Cataract evaluation was performed using photographs captured by the device. Van-Herick grading was assessed by the ratio of peripheral anterior chamber depth to peripheral corneal thickness, in addition to the iridocorneal angle using Image J software. Results The correlation coefficient between values obtained by AS-OCT, and our fabricated portable scanning slit-light device was notably high. The results indicate that our portable device is equally reliable as the conventional nonportable slit-lamp microscope and AS-OCT for screening and evaluating eye diseases. Conclusions Our fabricated device matches the functionality of the traditional slit lamp, offering a cost-effective and portable solution. Ideal for remote locations, healthcare facilities, or areas affected by disasters, our scanning slit-light device can provide easy access to initial eye examinations and supports digital eye healthcare initiatives.
Collapse
Affiliation(s)
- Neelam Kaushik
- Tohoku University Graduate School of Medicine, Department of Ophthalmology, Sendai, Japan
| | - Parmanand Sharma
- Tohoku University Graduate School of Medicine, Department of Ophthalmology, Sendai, Japan
- Tohoku University Graduate School of Medicine, Advanced Research Center for Innovations in Next-Generation Medicine, Sendai, Japan
| | - Noriko Himori
- Tohoku University Graduate School of Medicine, Department of Ophthalmology, Sendai, Japan
- Tohoku University Graduate School of Biomedical Engineering, Department of Aging Vision Healthcare, Sendai, Japan
| | - Takuro Matsumoto
- Tohoku University Graduate School of Medicine, Department of Ophthalmology, Sendai, Japan
| | - Takehiro Miya
- Tohoku University Graduate School of Medicine, Department of Ophthalmology, Sendai, Japan
| | - Toru Nakazawa
- Tohoku University Graduate School of Medicine, Department of Ophthalmology, Sendai, Japan
- Tohoku University Graduate School of Medicine, Advanced Research Center for Innovations in Next-Generation Medicine, Sendai, Japan
- Tohoku University Graduate School of Medicine, Department of Retinal Disease Control, Sendai, Japan
- Tohoku University Graduate School of Medicine, Department of Ophthalmic Imaging and Information Analytics, Sendai, Japan
- Tohoku University Graduate School of Medicine, Department of Advanced Ophthalmic Medicine, Sendai, Japan
| |
Collapse
|
2
|
Miao YY, Ma XM, Qu ZX, Eliasy A, Wu BW, Xu H, Wang P, Zheng XB, Wang JJ, Ye YF, Chen SH, Elsheikh A, Bao FJ. Performance of Corvis ST Parameters Including Updated Stress-Strain Index in Differentiating Between Normal, Forme-Fruste, Subclinical, and Clinical Keratoconic Eyes. Am J Ophthalmol 2024; 258:196-207. [PMID: 37879454 DOI: 10.1016/j.ajo.2023.10.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 10/18/2023] [Accepted: 10/20/2023] [Indexed: 10/27/2023]
Abstract
PURPOSE This study seeks to evaluate the ability of the updated stress strain index (SSIv2) and other Corvis ST biomechanical parameters in distinguishing between keratoconus at different disease stages and normal eyes. DESIGN Diagnostic accuracy analysis to distinguish disease stages. METHODS 1084 eyes were included and divided into groups of normal (199 eyes), forme fruste keratoconus (FFKC, 194 eyes), subclinical keratoconus (SKC, 113 eyes), mild clinical keratoconus (CKC-Ⅰ, 175 eyes), moderate clinical keratoconus (CKC-Ⅱ, 204 eyes), and severe clinical keratoconus (CKC-Ⅲ, 199 eyes). Each eye was subjected to a Corvis ST examination to determine the central corneal thickness (CCT), biomechanically corrected intraocular pressure (bIOP), SSIv2 (updated stress-strain index), and other 8 Corvis parameters including the stress-strain index (SSIv1), stiffness parameter at first applanation (SP-A1), first applanation time (A1T), Ambrósio relational thickness to the horizontal profile (ARTh), integrated inverse radius (IIR), maximum deformation amplitude (DAM), ratio between deformation amplitude at the apex and at 2 mm nasal and temporal (DARatio2), and Corvis biomechanical index (CBI). The sensitivity and specificity of these parameters in diagnosing keratoconus were analyzed through receiver operating characteristic curves. RESULTS Before and after correction for CCT and bIOP, SSIv2 and ARTh were significantly higher and IIR and CBI were significantly lower in the normal group than in the FFKC group, SKC group and the 3 CKC groups (all P < .05). There were also significant correlations between the values of SSIv2, ARTh, IIR, CBI, and the CKC severity (all P < .05). AUC of SSIv2 was significantly higher than all other Corvis parameters in distinguishing normal eyes from FFKC, followed by IIR, ARTh and CBI. CONCLUSION Corvis ST's updated stress-strain index, SSIv2, demonstrated superior performance in differentiating between normal and keratoconic corneas, and between corneas with different keratoconus stages. Similar, but less pronounced, performance was demonstrated by the IIR, ARTh and CBI.
Collapse
Affiliation(s)
- Yuan-Yuan Miao
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China
| | - Xiao-Min Ma
- Shanghai Eighth People's Hospital (X.-M.M.), Shanghai, China
| | - Zhan-Xin Qu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool (A.Eli., A.Els.), Liverpool, United Kingdom
| | - Bo-Wen Wu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China
| | - Hui Xu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China
| | - Pu Wang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China
| | - Xiao-Bo Zheng
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China; The Institute of Ocular Biomechanics, Wenzhou Medical University (X.-B.Z., J.-J.W., S.-H.C., F.-J.B.), Wenzhou, Zhejiang, China
| | - Jun-Jie Wang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China; The Institute of Ocular Biomechanics, Wenzhou Medical University (X.-B.Z., J.-J.W., S.-H.C., F.-J.B.), Wenzhou, Zhejiang, China
| | - Yu-Feng Ye
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China
| | - Shi-Hao Chen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China; The Institute of Ocular Biomechanics, Wenzhou Medical University (X.-B.Z., J.-J.W., S.-H.C., F.-J.B.), Wenzhou, Zhejiang, China.
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool (A.Eli., A.Els.), Liverpool, United Kingdom; National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology (A.Els.), London, United Kingdom; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University (A.Els.), Beijing, China
| | - Fang-Jun Bao
- National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China; The Institute of Ocular Biomechanics, Wenzhou Medical University (X.-B.Z., J.-J.W., S.-H.C., F.-J.B.), Wenzhou, Zhejiang, China.
| |
Collapse
|
3
|
Kuo AN, Cortina MS, Greiner MA, Li JY, Miller DD, Shtein RM, Veldman PB, Yin J, Kim SJ, Shen JF. Advanced Corneal Imaging in Keratoconus: A Report by the American Academy of Ophthalmology. Ophthalmology 2024; 131:107-121. [PMID: 37855776 DOI: 10.1016/j.ophtha.2023.07.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/31/2023] [Accepted: 07/31/2023] [Indexed: 10/20/2023] Open
Abstract
PURPOSE To review the published literature on the diagnostic capabilities of the newest generation of corneal imaging devices for the identification of keratoconus. METHODS Corneal imaging devices studied included tomographic platforms (Scheimpflug photography, OCT) and functional biomechanical devices (imaging an air impulse on the cornea). A literature search in the PubMed database for English language studies was last conducted in February 2023. The search yielded 469 citations, which were reviewed in abstract form. Of these, 147 were relevant to the assessment objectives and underwent full-text review. Forty-five articles met the criteria for inclusion and were assigned a level of evidence rating by the panel methodologist. Twenty-six articles were rated level II, and 19 articles were rated level III. There were no level I evidence studies of corneal imaging for the diagnosis of keratoconus found in the literature. To provide a common cross-study outcome measure, diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were extracted. (A perfect diagnostic test that identifies all cases properly has an AUC of 1.0.) RESULTS: For the detection of keratoconus, sensitivities for all devices and parameters (e.g., anterior or posterior corneal curvature, corneal thickness) ranged from 65% to 100%. The majority of studies and parameters had sensitivities greater than 90%. The AUCs ranged from 0.82 to 1.00, with the majority greater than 0.90. Combined indices that integrated multiple parameters had an AUC in the mid-0.90 range. Keratoconus suspect detection performance was lower with AUCs ranging from 0.66 to 0.99, but most devices and parameters had sensitivities less than 90%. CONCLUSIONS Modern corneal imaging devices provide improved characterization of the cornea and are accurate in detecting keratoconus with high AUCs ranging from 0.82 to 1.00. The detection of keratoconus suspects is less accurate with AUCs ranging from 0.66 to 0.99. Parameters based on single anatomic locations had a wide range of AUCs. Studies with combined indices using more data and parameters consistently reported high AUCs. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Anthony N Kuo
- Duke Eye Center, Duke University Medical Center, Durham, North Carolina
| | - Maria S Cortina
- Department of Ophthalmology and Visual Science, University of Illinois College of Medicine, Chicago, Illinois
| | - Mark A Greiner
- Department of Ophthalmology and Visual Sciences, Carver College of Medicine and Institute for Vision Research, University of Iowa, Iowa City, Iowa
| | - Jennifer Y Li
- University of California, Davis Eye Center, University of California, Davis, California
| | - Darby D Miller
- Department of Ophthalmology, Mayo Clinic, Jacksonville, Florida
| | - Roni M Shtein
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, Michigan
| | - Peter B Veldman
- Department of Ophthalmology and Visual Sciences, The University of Chicago, Chicago, Illinois
| | - Jia Yin
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | - Stephen J Kim
- Department of Ophthalmology, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Joanne F Shen
- Department of Ophthalmology, Mayo Clinic, Scottsdale, Arizona.
| |
Collapse
|
4
|
Yavangi M, Rabiee S, Sanavi Farimani M, Khansary S, Farhadian M, Ranjbar A, Mahmoudi M, Karimi M, Barati S, Barati Mosleh A, Mohammadpour N. The effects of green tea tablets and metformin on ovulation and menstrual cycle regularity in women with polycystic ovary syndrome. J Med Life 2024; 17:109-115. [PMID: 38737668 PMCID: PMC11080502 DOI: 10.25122/jml-2022-0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 12/28/2023] [Indexed: 05/14/2024] Open
Abstract
Polycystic ovary syndrome is the most common cause of oligo-ovulation and anovulation among women of reproductive age, contributing to infertility. This study aimed to compare the effects of green tea tablets and metformin on ovulation, menstrual cycle regularity, and antioxidant biomarkers in women with polycystic ovary syndrome (PCOS). In this clinical trial study, 94 women with PCOS were randomly assigned to three groups: green tea (n = 33), metformin (n = 29), and control (n = 32). Menstrual status and oxidative stress parameters, including total antioxidant capacity, thiol, and lipid peroxidation, were compared before and 3 months after the intervention among all three groups. Data analysis was conducted using SPSS software version 22 and employing the analysis of variance and paired t-tests. Following the intervention, the mean menstrual cycle duration in the green tea, metformin, and control groups was 32.22 ± 12.78, 48.72 ± 37.06, and 48.53 ± 31.04 days, respectively (P = 0.040). There was no statistically significant difference between the three groups in terms of biochemical, hormonal, and antioxidant indices before and after the intervention (P > 0.05). The intake of green tea tablets was associated with better outcomes in regulating the menstrual cycle in women with PCOS.
Collapse
Affiliation(s)
- Mahnaz Yavangi
- Department of Gynecology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Soghra Rabiee
- Department of Gynecology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Marzieh Sanavi Farimani
- Department of Gynecology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Shahede Khansary
- Department of Gynecology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Maryam Farhadian
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Akram Ranjbar
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Minoo Mahmoudi
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Masoud Karimi
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Somayeh Barati
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Amir Barati Mosleh
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Noushin Mohammadpour
- Department of Biostatistics, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
5
|
Ćirković A, Katz T. Exploring the Potential of ChatGPT-4 in Predicting Refractive Surgery Categorizations: Comparative Study. JMIR Form Res 2023; 7:e51798. [PMID: 38153777 PMCID: PMC10784977 DOI: 10.2196/51798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 11/01/2023] [Accepted: 12/04/2023] [Indexed: 12/29/2023] Open
Abstract
BACKGROUND Refractive surgery research aims to optimally precategorize patients by their suitability for various types of surgery. Recent advances have led to the development of artificial intelligence-powered algorithms, including machine learning approaches, to assess risks and enhance workflow. Large language models (LLMs) like ChatGPT-4 (OpenAI LP) have emerged as potential general artificial intelligence tools that can assist across various disciplines, possibly including refractive surgery decision-making. However, their actual capabilities in precategorizing refractive surgery patients based on real-world parameters remain unexplored. OBJECTIVE This exploratory study aimed to validate ChatGPT-4's capabilities in precategorizing refractive surgery patients based on commonly used clinical parameters. The goal was to assess whether ChatGPT-4's performance when categorizing batch inputs is comparable to those made by a refractive surgeon. A simple binary set of categories (patient suitable for laser refractive surgery or not) as well as a more detailed set were compared. METHODS Data from 100 consecutive patients from a refractive clinic were anonymized and analyzed. Parameters included age, sex, manifest refraction, visual acuity, and various corneal measurements and indices from Scheimpflug imaging. This study compared ChatGPT-4's performance with a clinician's categorizations using Cohen κ coefficient, a chi-square test, a confusion matrix, accuracy, precision, recall, F1-score, and receiver operating characteristic area under the curve. RESULTS A statistically significant noncoincidental accordance was found between ChatGPT-4 and the clinician's categorizations with a Cohen κ coefficient of 0.399 for 6 categories (95% CI 0.256-0.537) and 0.610 for binary categorization (95% CI 0.372-0.792). The model showed temporal instability and response variability, however. The chi-square test on 6 categories indicated an association between the 2 raters' distributions (χ²5=94.7, P<.001). Here, the accuracy was 0.68, precision 0.75, recall 0.68, and F1-score 0.70. For 2 categories, the accuracy was 0.88, precision 0.88, recall 0.88, F1-score 0.88, and area under the curve 0.79. CONCLUSIONS This study revealed that ChatGPT-4 exhibits potential as a precategorization tool in refractive surgery, showing promising agreement with clinician categorizations. However, its main limitations include, among others, dependency on solely one human rater, small sample size, the instability and variability of ChatGPT's (OpenAI LP) output between iterations and nontransparency of the underlying models. The results encourage further exploration into the application of LLMs like ChatGPT-4 in health care, particularly in decision-making processes that require understanding vast clinical data. Future research should focus on defining the model's accuracy with prompt and vignette standardization, detecting confounding factors, and comparing to other versions of ChatGPT-4 and other LLMs to pave the way for larger-scale validation and real-world implementation.
Collapse
Affiliation(s)
| | - Toam Katz
- Department of Ophthalmology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
6
|
Hashemi A, Khabazkhoob M, Narooei F, Mortazavi A, Hashemi H. Corneal topographic indices of scheimpflug camera in type 2 diabetic and non-diabetic elderly populations. BMC Ophthalmol 2023; 23:427. [PMID: 37872473 PMCID: PMC10594925 DOI: 10.1186/s12886-023-03169-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 10/10/2023] [Indexed: 10/25/2023] Open
Abstract
PURPOSE The present study was conducted to determine the corneal topographic indices of Scheimpflug camera in type 2 diabetes patients without diabetic retinopathy (DR), DR and non-diabetic elderly populations. METHODS A total of 1105 participants were selected using random cluster sampling from Tehran, Iran and categorized into three groups including type 2 diabetes patients without diabetic retinopathy (DR), DR and non-diabetic. The diabetic group had HbA1c levels ≥ 6.4% with no other systemic problems. The non-diabetic participants had normal eye findings and no systemic diseases. The pachymetric progression index (PPI) values were measured using the Pentacam AXL. RESULTS A total of 1105 participants including 429 diabetes patients (38.46% male) and 676 non-diabetic (38.76% male) subjects entered the study. Only PPIavg and PPImax were higher in the diabetics versus non-diabetics (P = 0.019 and 0.010, respectively). There was a significant difference in PPImax between the three groups (P = 0.036). There were significant differences only in index of vertical asymmetry (IVA), central keratoconus index (CKI), PPI average, and PPI max between different stages of diabetic retinopathy (DR) (P = 0.045, 0.005, 0.002, and 0.004, respectively). There was a significant difference in index of Surface Variance (ISV), index of vertical asymmetry (IVA), PPIavg, and PPImax between diabetes patients with and without DR (P = 0.016, 0.022, < 0.001, and < 0.001, respectively). CONCLUSION According to the results, diabetes and DR change several topographic indices. In addition, the HbA1c level may affect pachymetric progression index max. Therefore, special attention should be paid to these patients for different treatment strategies.
Collapse
Affiliation(s)
- Alireza Hashemi
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Mehdi Khabazkhoob
- Department of Basic Sciences, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Foroozan Narooei
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| | - Abolghasem Mortazavi
- Department of Neurosurgery, Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Hassan Hashemi
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran.
| |
Collapse
|
7
|
Xian Y, Zhao Y, Sun L, Zhang X, Ding L, Liu Z, Li Y, Ding Y, Jiang L, Zhou X, Shen Y. Comparison of bilateral differential characteristics of corneal biomechanics between keratoconus and normal eyes. Front Bioeng Biotechnol 2023; 11:1163223. [PMID: 37324412 PMCID: PMC10267412 DOI: 10.3389/fbioe.2023.1163223] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 05/12/2023] [Indexed: 06/17/2023] Open
Abstract
Purpose: To compare bilateral differences in corneal biomechanics between keratoconus and normal eyes. Methods: In this case-control study, 346 eyes of 173 patients (aged 22.1 ± 6.1 years) with keratoconus (KC group) and 378 eyes of 189 patients (aged 26.7 ± 5.6 years) with ametropia (control group) were enrolled. Corneal tomography and biomechanical properties were examined using Pentacam HR and Corvis ST, respectively. The corneal biomechanical parameters were compared between eyes with forme fruste keratoconus (FFKC) and normal eyes. Bilateral differences in corneal biomechanical parameters were compared between the KC and control groups. Receiver operating characteristic (ROC) analysis was used to assess discriminative efficacies. Results: The areas under the ROC curves (AUROCs) of stiffness parameter at the first applanation (SP-A1) and Tomographic and Biomechanical Index (TBI) for identifying FFKC were 0.641 and 0.694, respectively. The bilateral differential values of major corneal biomechanical parameters were significantly increased in the KC group (all p < 0.05), except for the Corvis Biomechanical Index (CBI). The AUROCs of the bilateral differential values of the deformation amplitude ratio at 2 mm (ΔDAR2), Integrated Radius (ΔIR), SP-A1 (ΔSP-A1), and the maximum inverse concave radius (ΔMax ICR) for discriminating keratoconus were 0.889, 0.884, 0.826, and 0.805, respectively. The Logistic Regression Model-1 (comprising of ΔDAR2, ΔIR, and age) and the Logistic Regression Model-2 (comprising of ΔIR, ΔARTh, ΔBAD-D, and age) had AUROCs of 0.922 and 0.998, respectively, for discriminating keratoconus. Conclusion: The bilateral asymmetry of corneal biomechanics was significantly increased in keratoconus compared with normal eyes, which may be helpful for the early detection of keratoconus.
Collapse
Affiliation(s)
- Yiyong Xian
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yu Zhao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Ling Sun
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xiaoyu Zhang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Lan Ding
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Zesheng Liu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yuan Li
- Shangqiu First People’s Hospital, Shangqiu, China
| | - Yanlan Ding
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Lin Jiang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yang Shen
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Key Laboratory of Myopia, Fudan University, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| |
Collapse
|
8
|
Fikret CZ, Ucgun NI, Karaca EE, Kemer OE. Corneal characteristics in patients with Retinitis Pigmentosa. Photodiagnosis Photodyn Ther 2023; 42:103554. [PMID: 37030435 DOI: 10.1016/j.pdpdt.2023.103554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 04/03/2023] [Accepted: 04/03/2023] [Indexed: 04/10/2023]
Abstract
BACKGROUND To evaluate corneal topography and specular microscopic findings in patients with retinitis pigmentosa. METHODS One hundred and two eyes of 51 patients with retinitis pigmentosa and 60 eyes of 30 healty subjects were included in our study. A detailed ophthalmological examination involving best corrected visual acuity (BCVA) was performed. A rotating Scheimpflug imaging system, was used to evaluate all eyes for topographic and aberrometrics parameters. Specular microscopy measurements were also noted. RESULTS The retinitis pigmentosa group consisted of 51 patients (29 male and 22 female, mean age of 35.61±13.55 (18-65) years and the control group also consisted of 30 healty subjects (29 male and 22 female, mean age of 33.67±9.92 (20-58) years. There was no difference between the groups in terms of age (p=0.624) and gender (p=0.375). Spherical equivalents were higher in the RP group (p<0.001). Central keratoconus index (CKI) (p<0.001), Belin Ambrosio enhanced ectasia display total deviation value (BAD-D) (p=0.003), index of surface variance (ISV) (p<0.001), index of vertical asymmetry (IVA) (p<0.001), Ambrosio related thickness (ART max) (p=0.018), index of height asymmetry (IHA) (p=0.009), index of height decentration (IHD) (p<0.001), maximum anterior elevation (p<0.001), front elevation in thin location (p=0.05), progression index average (p=0.015), root mean square (RMS) total (p=0.010) and RMS-higher order aberration (RMS-HOA) (p<0.001) values were higher in RP group. There was a weak negative correlation between BCVA and ART max measurements (r=-0.256, p=0.009) in RP group. We detected keratoconus-suspect in 6 eyes and clinically manifest keratoconus in one eye in the RP group. CONCLUSIONS Patients with retinitis pigmentosa may have corneal morphological disorders that may affect vision. In our study, corneal topographic pathologies including keratoconus and possible keratoconus were detected in RP patients.
Collapse
Affiliation(s)
- Cenk Zeki Fikret
- Ankara City Hospital, Ankara, Turkey, Department of Ophthalmology.
| | - Nil Irem Ucgun
- University of Health Sciences, Ankara City Hospital, Ankara, Turkey, Department of Ophthalmology.
| | | | - Ozlem Evren Kemer
- University of Health Sciences, Ankara City Hospital, Ankara, Turkey, Department of Ophthalmology.
| |
Collapse
|
9
|
Achiron A, Yavnieli R, Olshaker H, Levinger E, Tuuminen R, Livny E, Elbaz U, Bahar I, Nahum Y. Validation of the multi-metric D-index change in the assessment of keratoconus progression. Int Ophthalmol 2022; 42:2665-2671. [PMID: 35381894 DOI: 10.1007/s10792-022-02255-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Accepted: 03/12/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE To validate the effectiveness of the multi-metric D-index by Pentacam in detecting keratoconus (KC) progression. MATERIALS AND METHODS This was a retrospective study of KC patients at the Rabin Medical Center, Petah Tikva, Israel, during 2016-2018 with at least two corneal tomography examinations six months apart. Agreement between clinical diagnosis of progression (1.5D increase in mean keratometric value, 1D increase in Kmax, a 5% decrease in central corneal thickness (CCT), worsening of visual acuity by more than one line, or deterioration of manifest corneal astigmatism > 1.5D) and the D-index was evaluated. Receiver operating characteristic (ROC) analysis was used to find the D-index's optimal cutoff value to show progression. RESULTS We included KC eyes in the stable group (N = 7) and the progression group (N = 54). Patient demographics and tomographic parameters at baseline were similar between the groups. The D-index change was significantly higher in the progression group than in the stable group (median + 1 and 0.0, respectively, p = 0.024). Based on the ROC analysis, the optimal D-index cutoff change within at least six months was 0.32 (59.3% sensitivity and 100% specificity (area under the curve [AUC] = 0.771, Youden = 0.592). Subjects with a D-index change above this value had a 21.1-fold increase in odds for corneal ectasia progression requiring CXL (OR: 21.1, 95%CI 1.17-398.8, p = 0.038). CONCLUSION The multi-metric D-index can serve as a clinically feasible parameter to detect KC progression and guide patients' referral for further interventions.
Collapse
Affiliation(s)
- Asaf Achiron
- Department of Ophthalmology, Rabin Medical Center, 39 Ze'ev Jabotinsky St., 4941492, Petah-Tikva, Israel. .,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Roy Yavnieli
- Department of Ophthalmology, Rabin Medical Center, 39 Ze'ev Jabotinsky St., 4941492, Petah-Tikva, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Hagar Olshaker
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Department of Ophthalmology, Sackler Faculty of Medicine, Tel Aviv Medical Center, Tel Aviv, Israel
| | - Eliya Levinger
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Department of Ophthalmology, Sackler Faculty of Medicine, Tel Aviv Medical Center, Tel Aviv, Israel
| | - Raimo Tuuminen
- Department of Ophthalmology, Kymenlaakso Central Hospital, Kotka, Finland.,Helsinki Retina Research Group, Faculty of Medicine, University of Helsinki, Helsinki, Finland
| | - Eitan Livny
- Department of Ophthalmology, Rabin Medical Center, 39 Ze'ev Jabotinsky St., 4941492, Petah-Tikva, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Uri Elbaz
- Department of Ophthalmology, Rabin Medical Center, 39 Ze'ev Jabotinsky St., 4941492, Petah-Tikva, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Irit Bahar
- Department of Ophthalmology, Rabin Medical Center, 39 Ze'ev Jabotinsky St., 4941492, Petah-Tikva, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yoav Nahum
- Department of Ophthalmology, Rabin Medical Center, 39 Ze'ev Jabotinsky St., 4941492, Petah-Tikva, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
10
|
Diagnostic Value of Corneal Epithelial and Stromal Thickness Distribution Profiles in Forme Fruste Keratoconus and Subclinical Keratoconus. Cornea 2021; 40:61-72. [PMID: 32769675 DOI: 10.1097/ico.0000000000002435] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE To assess the diagnostic values of corneal epithelial and stromal thickness distribution characteristics in forme fruste keratoconus (FFKC) and subclinical keratoconus (KC). METHODS This cross-sectional study was conducted at VISSUM Innovation and Miguel Hernandez University, Alicante, Spain. Twenty-seven eyes (27 subjects) with FFKC, 50 eyes (50 subjects) with subclinical KC with a best spectacle corrected distance visual acuity ≥20/20 (Snellen) (grade zero KC according to the Red Temática de Investigación Cooperativa en Salud classification), and 66 control eyes (66 subjects) were included. Epithelial and stromal thicknesses and epithelium/stroma (E/S) thickness ratio at center, thinnest point, 5-, and 8-mm circles obtained from the MS-39 device (CSO, Firenze, Italy) were compared among the control, FFKC, and subclinical KC groups. RESULTS The FFKC group had thinner 8-mm superior-nasal epithelium and higher central E/S ratio compared with the control group (P < 0.05). In the subclinical KC group, the E/S ratios in the 5-mm temporal and superior zones were higher than those in the control group (P < 0.05). The FFKC and subclinical KC groups had thinner stroma compared with the control group (P < 0.05). A two-parameter formula correctly classified 94% of the eyes with subclinical KC and 98.5% of the normals, whereas another three-parameter model had 75% sensitivity and 94.3% specificity for discriminating FFKC from normals. CONCLUSIONS This study identified different epithelial distributional and behavioral patterns in eyes with FFKC and subclinical KC. Eyes with FFKC seem to have increased central E/S ratio and asymmetric superior-nasal epithelial thinning, whereas keratometric and volumetric alterations seem to be more prominent in subclinical KC.
Collapse
|
11
|
Differentiating highly asymmetric keratoconus eyes using a combined Scheimpflug/Placido device. J Cataract Refract Surg 2021; 46:1588-1595. [PMID: 32818347 DOI: 10.1097/j.jcrs.0000000000000358] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE To determine the ability to differentiate between normal eyes and clinically unaffected eyes of patients with highly asymmetric keratoconus (AKC) using a Scheimpflug/Placido device. SETTING Tel Aviv Sourasky Medical Center and Enaim Medical Center, Israel. DESIGN Retrospective case-control. METHODS Imaging from a combined Scheimpflug/Placido device (Sirius, C.S.O.) was obtained from 26 clinically unaffected eyes of patients with frank keratoconus in the fellow eye, and 166 eyes from 166 patients with bilaterally normal corneal examinations that underwent uneventful corneal refractive surgery with at least 1 year of follow-up. Receiver operating characteristic curves were produced to calculate the area under the curve, sensitivity, and specificity of 60 metrics, and finally a logistic regression modeling was used to determine optimal variables to differentiate populations. RESULTS The most predictive individual metric able to differentiate between 26 eyes in the case group to 166 eye in the control group was the posterior wall inferior-superior (I-S) ratio, with an receiver operating characteristics (ROC) of 0.862. A combination model of 4 metrics (posterior wall I-S ratio in the central 3 mm, thinnest pachymetry coordinate on the x horizontal axis, posterior asymmetry and asphericity index, corneal volume) yielded an ROC of 0.936, with a sensitivity/specificity pair of 92.3%/87%. Variables related to elevation were not found significant. CONCLUSIONS Using a combination of metrics from a combined Scheimpflug/Placido device, a practical model for discrimination between clinically normal eyes of patients with highly AKC and normal eyes was constructed. Variables related to pachymetry and posterior cornea asymmetry were the most impactful.
Collapse
|
12
|
Shneor E, Piñero DP, Doron R. Contrast sensitivity and higher-order aberrations in Keratoconus subjects. Sci Rep 2021; 11:12971. [PMID: 34155283 PMCID: PMC8217180 DOI: 10.1038/s41598-021-92396-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 06/09/2021] [Indexed: 02/05/2023] Open
Abstract
This study analyzes the relationship between contrast-sensitivity and higher-order aberrations (HOA) in mild and subclinical-keratoconus in subjects with good visual-acuity (VA). Keratoconus group (including subclinical-keratoconus) and controls underwent autokeratometry, corneal-tomography, autorefraction and HOA measurement. Contrast-sensitivity was tested using a psychophysical two-alternative forced-choice Gabor patches in three blocks (6, 9, 12 cycles/deg). Controls were compared to the keratoconus group and to a keratoconus subgroup with VA of 0.00 LogMar group ("keratoconus-0.00VA"). Spearman correlation tested association between HOA and contrast-sensitivity. Twenty-two keratoconus subjects (38 eyes: 28 keratoconus, 10 subclinical-keratoconus, 20 keratoconus-0.00VA) and 35 controls were included. There was a significant difference between control and keratoconus, and between control and keratoconus-0.00VA, for keratometry, cylinder, thinnest and central corneal thickness (p < 0.001). Controls showed lower HOA and higher contrast-sensitivity for all spatial-frequencies (p < 0.001). Most HOA were negatively correlated with contrast-sensitivity for all spatial-frequencies for keratoconus group and for 9 and 12 cycles/deg for keratoconus-0.00VA. Keratoconus subjects with good VA showed reduction in contrast-sensitivity and increased HOAs compared to controls. HOA and contrast-sensitivity are inversely correlated in subjects with mild keratoconus despite good VA. This suggests that the main mechanism underlying the decreased vision quality in keratoconus is the increase of HOA.
Collapse
Affiliation(s)
- Einat Shneor
- Department of Optometry and Vision Science, Hadassah Academic College, Haniviim St. 37, 9101001, Jerusalem, Israel.
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - Ravid Doron
- Department of Optometry and Vision Science, Hadassah Academic College, Haniviim St. 37, 9101001, Jerusalem, Israel
| |
Collapse
|
13
|
Rodrigues FW, Vilela ABV, Nishi JF, Silva RED. Análise comparativa entre os índices tomográficos em pacientes com ceratocone inicial. REVISTA BRASILEIRA DE OFTALMOLOGIA 2021. [DOI: 10.37039/1982.8551.20210003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
14
|
Shimizu E, Yazu H, Aketa N, Yokoiwa R, Sato S, Yajima J, Katayama T, Sato R, Tanji M, Sato Y, Ogawa Y, Tsubota K. A Study Validating the Estimation of Anterior Chamber Depth and Iridocorneal Angle with Portable and Non-Portable Slit-Lamp Microscopy. SENSORS (BASEL, SWITZERLAND) 2021; 21:1436. [PMID: 33669487 PMCID: PMC7921911 DOI: 10.3390/s21041436] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 02/13/2021] [Accepted: 02/17/2021] [Indexed: 11/16/2022]
Abstract
This study assessed the anterior chamber depth (ACD) and iridocorneal angle using a portable smart eye camera (SEC) compared to the conventional slit-lamp microscope and anterior-segment optical coherence tomography (AS-OCT). This retrospective case-control study included 170 eyes from 85 Japanese patients. The correlation between the ACD evaluations conducted with the SEC and conventional slit-lamp was high (r = 0.814). The correlation between the Van-Herick Plus grade obtained using two devices was also high (r = 0.919). A high kappa value was observed for the Van-Herick Plus grading (Kappa = 0.757). A moderate correlation was observed between the ACD measured using AS-OCT and the slit-lamp image acquired with the conventional slit-lamp microscope and SEC (r = 0.609 and 0.641). A strong correlation was observed between the trabecular-iris angle (TIA) measured using AS-OCT and Van-Herick Plus grade obtained with the conventional slit-lamp microscope and SEC (r = 0.702 and 0.764). Strong correlations of ACD evaluation and high kappa value of the Van-Herick Plus grading indicated the adequate subjective assessment function of the SEC. Moderate correlations between the ACD objective measurement and evaluation and strong correlation between the TIA and Van-Herick Plus grade suggested the good objective assessment function of the SEC. The SEC demonstrated adequate performance for ACD evaluation and angle estimation.
Collapse
Affiliation(s)
- Eisuke Shimizu
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
- OUI Inc., Tokyo 160-0022, Japan;
- Yokohama Keiai Eye Clinic, Kanagawa 240-0065, Japan
| | - Hiroyuki Yazu
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
- OUI Inc., Tokyo 160-0022, Japan;
- Yokohama Keiai Eye Clinic, Kanagawa 240-0065, Japan
- Department of Ophthalmology, Tsurumi University School of Dental Medicine, Kanagawa 230-8501, Japan
| | - Naohiko Aketa
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
| | | | - Shinri Sato
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
- Yokohama Keiai Eye Clinic, Kanagawa 240-0065, Japan
| | - Junichiro Yajima
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
| | - Taiichiro Katayama
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
| | - Rio Sato
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
| | - Makoto Tanji
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
- OUI Inc., Tokyo 160-0022, Japan;
| | - Yasunori Sato
- Department of Preventive Medicine and Public Health, School of Medicine, Keio University, Tokyo 160-8582, Japan;
| | - Yoko Ogawa
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
| | - Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan; (H.Y.); (N.A.); (S.S.); (J.Y.); (T.K.); (R.S.); (M.T.); (Y.O.); (K.T.)
| |
Collapse
|
15
|
Henriquez MA, Hadid M, Izquierdo L. A Systematic Review of Subclinical Keratoconus and Forme Fruste Keratoconus. J Refract Surg 2021; 36:270-279. [PMID: 32267959 DOI: 10.3928/1081597x-20200212-03] [Citation(s) in RCA: 59] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Accepted: 02/10/2020] [Indexed: 02/07/2023]
Abstract
PURPOSE To identify the definitions used for the terms sub-clinical keratoconus and forme fruste keratoconus in published articles. METHODS This was a prospective, systematic literature review of the electronic database in PubMed, the Cochrane Library, and LILACS Database of all studies using the keywords "subclinical keratoconus" and/or "forme fruste keratoconus" until August 18, 2017. Two independent reviewers analyzed the data. The inclusion criteria for articles were having analyzed subclinical keratoconus or forme fruste keratoconus eyes with a sample size greater than 10 eyes; containing the definition of subclinical keratoconus or forme fruste keratoconus; and the quality of published reports was assessed using standards quality index methods. The following aspects of the selected articles were then analyzed: inclusion criteria for definition and technology used. RESULTS A total of 198 and 95 studies, respectively, including the definition of subclinical keratoconus and forme fruste keratoconus were collected in an initial search, of which 165 and 73 studies, respectively, were excluded. Definitions for subclinical keratoconus and forme fruste keratoconus included the criteria of having keratoconus in the fellow eye in 72.72% (24 of 33) and 77.27% (17 of 22) of the articles, respectively. A total of 96.97% (32 of 33) and 90.90% (20 of 22) of the studies used more than one parameter to define subclinical keratoconus and forme fruste keratoconus, respectively. The most common extra parameters included normal slit-lamp examination and cornea on slit-lamp biomicroscopy and inferior-superior asymmetry and/or bowtie pattern with skewed radial axes. CONCLUSIONS This review demonstrates the lack of unified criteria to define subclinical keratoconus and forme fruste keratoconus. According to the literature review, the most common subclinical keratoconus definition used refers to an eye with topographic signs of keratoconus and/or suspicious topographic findings under normal slit-lamp examination and keratoconus in the fellow eye and the most common forme fruste keratoconus definition refers to an eye with normal topography, normal slit-lamp examination, and keratoconus in the fellow eye. [J Refract Surg. 2020;36(4):270-279.].
Collapse
|
16
|
A Combined Biomechanical and Tomographic Model for Identifying Cases of Subclinical Keratoconus. Cornea 2021; 39:461-467. [PMID: 31738245 DOI: 10.1097/ico.0000000000002205] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To develop a combined biomechanical and tomographic model for identifying eyes with subclinical keratoconus (SKC) that are categorized as normal or borderline in the Pentacam Belin/Ambrósio Enhanced Ectasia Display. METHODS This case-control study comprised 62 eyes with SKC and randomly selected eyes of 186 age-matched healthy controls. SKC was defined as the presence of the following: 1) normal topography, topometric indices, and slit lamp; 2) normal or borderline Belin/Ambrósio Enhanced Ectasia Display D index, back and front elevation difference; and 3) keratoconus in the fellow eye. Stepwise logistic regression analysis was performed to identify the best variable combination for detecting SKC cases from Ocular Response Analyzer and Pentacam parameters. Receiver operating characteristic curve analysis was used to determine the predictive accuracy [area under the curve (AUC)] of the model. Based on the predictors in the final logistic regression model, a linear equation was derived using the discriminant function analysis. RESULTS The final model (AUC: 0.948, sensitivity: 87.1%, and specificity: 91.4%) chose corneal hysteresis (CH) and D index from a total of 63 candidate variables. The final model had a higher AUC compared with D (0.933, P = 0.053) and CH (0.80, P < 0.001) alone. According to the discriminant function analysis, a higher CH was required with increasing D index to classify an eye as normal. CONCLUSIONS The proposed combined model provided varying cutoffs for CH and D as a function of the other. The probability plot as a function of CH and D index may be used for identifying eyes with SKC.
Collapse
|
17
|
Masiwa LE, Moodley V. A review of corneal imaging methods for the early diagnosis of pre-clinical Keratoconus. JOURNAL OF OPTOMETRY 2020; 13:269-275. [PMID: 31917136 PMCID: PMC7520528 DOI: 10.1016/j.optom.2019.11.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 10/22/2019] [Accepted: 11/09/2019] [Indexed: 05/15/2023]
Abstract
BACKGROUND Keratoconus (KC) is a corneal ectasia characterised by steepening corneal curvature, changes in refractive error and corneal thickness that result in visual impairment. Early signs of KC include displacement of the thinnest part of the cornea from the central position, changes in the corneal epithelial layer cell distribution, variations in the anterior corneal astigmatism/posterior corneal astigmatism relationship and a variation in corneal thickness. It is important that we review the corneal imaging methods for the diagnosis of preclinical KC. METHOD An online literature search was carried out on PubMed. Only publications detailing corneal assessment procedures were considered for this review and any publication on instruments that did not generate KC predictability indices were also excluded from the review. The 308 publications were reviewed. DISCUSSION Corneal assessment techniques, with the ability to characterise both the anterior and posterior corneal surfaces, are invaluable in the diagnosis of pre-clinical KC. Reflection based and elevation based corneal imaging systems should be used in conjunction with other assessments such as higher order aberration measuring systems to improve sensitivity and reliability in the diagnosis of pre-clinical KC. Ultra high resolution ultrasound can detect pre-clinical KC. The ability to asses both the epithelium and endothelium makes anterior surface optical coherence tomography a superior technique for pre-clinical KC diagnosis. There is a positive correlation between central corneal thickness and corneal hysteresis. Corneal biomechanics should be considered in conjunction with other corneal assessments in the diagnosis of pre-clinical KC.
Collapse
Affiliation(s)
- Lynett Erita Masiwa
- Department of Ophthalmology, University of Zimbabwe, College of Health Sciences, P. O. Box A178, Avondale, Harare, Zimbabwe.
| | - Vanessa Moodley
- School of Health Sciences, Department of Optometry, University of Kwazulu Natal, Durban, South Africa
| |
Collapse
|
18
|
Anterior and posterior ratio of corneal surface areas: A novel index for detecting early stage keratoconus. PLoS One 2020; 15:e0231074. [PMID: 32240243 PMCID: PMC7117727 DOI: 10.1371/journal.pone.0231074] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 03/15/2020] [Indexed: 11/30/2022] Open
Abstract
Purpose To evaluate the diagnostic ability of the ratio of anterior and posterior corneal surface areas (As/Ps) comparing with other keratoconus screening indices in distinguishing forme fruste keratoconus (FFKC) from normal eyes. Methods In this comparative study, 13 eyes of 13 patients with FFKC, 29 eyes of 29 patients with keratoconus (KC) and 88 eyes of 88 patients with normal subjects were involved. The As/Ps measured by the anterior segment optical coherence tomography (AS-OCT) and other indices measured by AS-OCT and rotating Scheimpflug–based corneal tomography were evaluated. The area under receiver-operating-characteristics (AU-ROC) was calculated to assess the diagnostic ability in discriminating FFKC from normal eyes. Results The As/Ps, the Belin/Ambrosio display enhanced ectasia total derivation value (BAD-D) and posterior and anterior elevation values showed the AU-ROC 0.9 or more in differentiating FFKC from normal eyes (0.980, 0.951, 0.924 and 0.903, respectively). The sensitivity and specificity were 0.92 and 0.96 for the As/Ps, 1.00 and 0.90 for BAD-D, 0.85 and 0.86 for posterior elevation value, and 0.85 and 0.96 for anterior elevation value, respectively. Conclusions Among the several indices for keratoconus screening which we evaluated, the As/Ps obtained by AS-OCT had the large AU-ROC with high sensitivity and specificity in detecting FFKC, which was comparable with BAD-D obtained by rotating Scheimpflug–based corneal tomography. The As/Ps may provide information for improving the diagnostic accuracy of KC, even in the initial stage of the disease.
Collapse
|
19
|
Koc M, Tekin K, Kiziltoprak H, Inanc M, Kosekahya P, Ozulken K, Durukan I. Topometric and Tomographic Evaluation of Subclinical Keratoconus. Ophthalmic Epidemiol 2020; 27:289-297. [PMID: 32172662 DOI: 10.1080/09286586.2020.1741010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
PURPOSE To investigate the corneal topometric and tomographic findings that can be used in the diagnosis of subclinical keratoconus. METHODS A retrospective cohort study. The study group was selected from patients with clinically evident keratoconus in one eye and subclinical keratoconus without evident topographic findings in fellow eye. The age-matched control group was selected from patients who were candidates for laser in situ keratomileusis (LASIK) and did not develop ectasia after LASIK surgery at least 1-year follow-up. All subjects underwent topographic, topometric and tomographic (Belin-Ambrósio Enhanced Ectasia Display III) analyses via a Pentacam HR rotating Scheimpflug camera (Oculus, Germany, version 1.20r.98) before LASIK surgery. RESULTS The study group consisted of 151 patients (69 male and 82 female, mean age of 24.8 ± 7.2 years) and the control group also consisted of 150 patients (70 male and 80 female, mean age of 26.0 ± 6.3 years). There were statistically significant differences in all measured topometric (p˂.05) and tomographic (p˂.001) parameters between the eyes with subclinical keratoconus and those of the control group. In discriminating eyes with subclinical keratoconus from normal eyes, final D showed the highest area under curve value (0.858, sensitivity 85.2%, specificity 66.7%), followed by maximum pachymetric progression index (0.809, sensitivity 81.9%, specificity 69.4%) and average pachymetric progression index (0.796, sensitivity 81.9%, specificity 68.1%) in receiver operating characteristic analysis. CONCLUSION Topometric and tomographic parameters might be useful for early detection of keratoconus, but the sensitivity and specificity of any parameter are not high enough to be used alone.
Collapse
Affiliation(s)
- Mustafa Koc
- Ophthalmology Department, Ankara Ulucanlar Eye Training and Research Hospital , Ankara, Turkey
| | - Kemal Tekin
- Ophthalmology Department, Ercis State Hospital , Van, Turkey
| | - Hasan Kiziltoprak
- Ophthalmology Department, Ankara Ulucanlar Eye Training and Research Hospital , Ankara, Turkey
| | - Merve Inanc
- Ophthalmology Department, Ercis State Hospital , Van, Turkey
| | - Pinar Kosekahya
- Ophthalmology Department, Ankara Ulucanlar Eye Training and Research Hospital , Ankara, Turkey
| | - Kemal Ozulken
- Ophthalmology Department, TOBB ETU Hospital , Ankara, Turkey
| | - Irfan Durukan
- Ophthalmology department, Era Eye Hospital , Ankara, Turkey
| |
Collapse
|
20
|
A Machine-Learning Model Based on Morphogeometric Parameters for RETICS Disease Classification and GUI Development. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10051874] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
This work pursues two objectives: defining a new concept of risk probability associated with suffering early-stage keratoconus, classifying disease severity according to the RETICS (Thematic Network for Co-Operative Research in Health) scale. It recruited 169 individuals, 62 healthy and 107 keratoconus diseased, grouped according to the RETICS classification: 44 grade I; 18 grade II; 15 grade III; 15 grade IV; 15 grade V. Different demographic, optical, pachymetric and eometrical parameters were measured. The collected data were used for training two machine-learning models: a multivariate logistic regression model for early keratoconus detection and an ordinal logistic regression model for RETICS grade assessments. The early keratoconus detection model showed very good sensitivity, specificity and area under ROC curve, with around 95% for training and 85% for validation. The variables that made the most significant contributions were gender, coma-like, central thickness, high-order aberrations and temporal thickness. The RETICS grade assessment also showed high-performance figures, albeit lower, with a global accuracy of 0.698 and a 95% confidence interval of 0.623–0.766. The most significant variables were CDVA, central thickness and temporal thickness. The developed web application allows the fast, objective and quantitative assessment of keratoconus in early diagnosis and RETICS grading terms.
Collapse
|
21
|
Hashemi H, Asgari S, Mehravaran S, Emamian MH, Fotouhi A. Keratoconus after 40 years of age: a longitudinal comparative population-based study. Int Ophthalmol 2019; 40:583-589. [PMID: 31701363 DOI: 10.1007/s10792-019-01216-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 11/02/2019] [Indexed: 11/28/2022]
Abstract
PURPOSE To determine 5-year changes in keratoconus indices and corrected distance visual acuity in 40-64-year-old keratoconus compared with normal subjects. METHODS In this prospective population-based cohort study, 5-year changes in Belin grading system indices including the average radii of curvature in the 3 mm zone surrounding the thinnest point in the anterior (ARC-3 mm) and posterior (PRC-3 mm) cornea, corrected distance visual acuity, minimum corneal thickness, maximum Ambrosio's relational thickness (ART-max), and maximum anterior keratometry indices centered on steepest point in the central 3 mm (Kmax-3 mm), 4 mm (Kmax-4 mm), and 5 mm (Kmax-5 mm) zones were compared between keratoconus and normal participants. In the analysis, comparisons were made between all keratoconus eyes and the right eyes of normal participants. RESULTS The mean age in the keratoconus (n = 16 eyes) and normal (n = 1986 eyes) groups (48.31 ± 4.78, 49.37 ± 5.79 years, respectively) was not statistically different (P = 0.327). The two groups differed in terms of changes in PRC-3 mm (- 0.07 ± 0.15 vs. + 0.001 ± 0.14 mm, respectively, P = 0.042) and ART-max (- 6.28 ± 25.19 vs. + 15.8 ± 72.7 μm, respectively, P = 0.003). There were significant correlations between the reduction in PRC-3 mm and its baseline value (β = - 0.20, P < 0.001) and keratoconus (β = - 0.26, P < 0.001). The reduction in ART-max significantly correlated with its baseline value (β = - 0.43, P < 0.001) and keratoconus (β = - 111.74, P < 0.001). CONCLUSION According to these findings, posterior corneal steepening and thinning in keratoconus patients continue after the age of 40 years, but it is clinically negligible. The changes are independent of normal age-related changes and appear to be slower in cases with steeper and thinner corneas.
Collapse
Affiliation(s)
- Hassan Hashemi
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Soheila Asgari
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Shiva Mehravaran
- ASCEND Center for Biomedical Research, Morgan State University, Baltimore, MD, USA
| | - Mohammad Hassan Emamian
- Ophthalmic Epidemiology Research Center, Shahroud University of Medical Sciences, Shahroud, Iran
| | - Akbar Fotouhi
- Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, PO Box: 14155-6446, Tehran, Iran.
| |
Collapse
|
22
|
Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes. Sci Rep 2019; 9:15379. [PMID: 31653884 PMCID: PMC6814725 DOI: 10.1038/s41598-019-51502-4] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Accepted: 10/02/2019] [Indexed: 12/28/2022] Open
Abstract
To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects were recruited in current study. All participants received three repeated measurements with 2 to 5 minutes interval. The interclass correlation coefficient (ICC), Cronbach' α and repeatability coefficient (RC) were evaluated. The liner regression analysis was used to identify factors that affect the repeatability, and linear mixed effects model was performed to compare the parameters differences. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic ability of new parameters. Eighteen parameters in normal eyes and twenty-two parameters in keratoconus eyes showed excellent repeatability (ICC ≥ 0.90). Age, axial measurement (AL), spherical equivalent, astigmatism, gender, mean keratometry (Kmean), intraocular pressure (IOP) and central corneal thickness (CCT) could affect the repeatability of new Corvis ST parameters. Compared with normal eyes, the Ambrósio's Relational Thickness horizontal (ARTh), biomechanical corrected IOP (bIOP), stiffness parameter at first applanation (SP A1) were low and the Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and Corvis Biomechanical Index (CBI) were high in keratoconus eyes (All P < 0.05). Both ARTh and CBI had high Youden index (0.870), and the corresponding cut-off values were 379.29 and 0.44. The repeatability of Corvis ST parameters was acceptable both in normal and keratoconus eyes, and new parameters could effectively diagnose keratoconus eyes from normal eyes.
Collapse
|
23
|
Kitazawa K, Itoi M, Yokota I, Wakimasu K, Cho Y, Nakamura Y, Hieda O, Kinoshita S, Sotozono C. Involvement of anterior and posterior corneal surface area imbalance in the pathological change of keratoconus. Sci Rep 2018; 8:14993. [PMID: 30302021 PMCID: PMC6177437 DOI: 10.1038/s41598-018-33490-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Accepted: 09/26/2018] [Indexed: 12/19/2022] Open
Abstract
Keratoconus (KC) is an ectatic disorder with a high prevalence rate. However, the exact cause of the disease and possible underlying mechanisms of development remain unclear. In this present study, we aimed to investigate the anterior and the posterior corneal surface area in normal, forme fruste keratoconus (FFKC), and keratoconic eyes (as a reference group) using anterior segment optical coherence tomography (AS-OCT) in order to assess the pathological change of KC. The surface areas of the anterior or posterior cornea, and the anterior-posterior (As/Ps) ratio of corneal surface area, were measured at the central 5.0 mm-, 6.0 mm-, and 7.0 mm-diameter areas via AS-OCT, and a comparison between the normal eyes and FFKC eyes was then performed using the Mann-Whitney U test. The posterior surface area at the central 5.0 mm areas in the FFKC eyes (20.430 mm2) and KC eyes (20.917 mm2) seemed to become larger than that of normal eyes (20.389 mm2) (normal vs FFKC; P = 0.06). Moreover, the As/Ps of the corneal surface area in the FFKC eyes (0.986) and the KC eyes (0.976) was significantly smaller than that of the normal eyes (0.988) (normal vs FFKC; P < 0.01). Anterior and posterior corneal surface area imbalance may reflect keratoconic eyes at the early stage of the disease.
Collapse
Affiliation(s)
- Koji Kitazawa
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan. .,Department of Frontier Medical Science and Technology for Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan. .,Baptist Eye Institute, Kyoto, Japan.
| | - Motohiro Itoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Isao Yokota
- Department of Biostatistics, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | | | - Yuko Cho
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yo Nakamura
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Osamu Hieda
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Shigeru Kinoshita
- Department of Frontier Medical Science and Technology for Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Chie Sotozono
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|
24
|
Hwang ES, Perez-Straziota CE, Kim SW, Santhiago MR, Randleman JB. Distinguishing Highly Asymmetric Keratoconus Eyes Using Combined Scheimpflug and Spectral-Domain OCT Analysis. Ophthalmology 2018; 125:1862-1871. [PMID: 30055838 DOI: 10.1016/j.ophtha.2018.06.020] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 06/05/2018] [Accepted: 06/14/2018] [Indexed: 12/17/2022] Open
Abstract
PURPOSE To determine optimal objective, machine-derived variables and variable combinations from Scheimpflug and spectral-domain (SD) OCT imaging to distinguish the clinically unaffected eye in patients with asymmetric keratoconus (AKC) from a normal control population. DESIGN Retrospective case-control study. PARTICIPANTS Thirty clinically unaffected eyes with no physical findings on slit-lamp examination, no definitive abnormalities on corneal imaging, and corrected distance acuity of 20/20 or better from 30 patients with highly AKC eyes and 60 eyes from 60 normal control patients who had undergone uneventful LASIK with at least 2 years of stable follow-up (controls). METHODS Scheimpflug and SD OCT imaging were obtained in all eyes, and receiver operating characteristic (ROC) curves were generated to determine area under the curve (AUC), sensitivity, and specificity for each machine-derived variable and variable combination. MAIN OUTCOME MEASURES Distinguishing AKC eyes from controls as determined by AUC, sensitivity, and specificity. RESULTS No individual machine-derived metric from Scheimpflug or SD OCT technology yielded an AUC higher than 0.75. Combining 5 Scheimpflug metrics (index height decentration [IHD], index vertical asymmetry [IVA], pachymetry apex, inferior-superior value, and Ambrosio's Relational Thickness Maximum [ARTmax]) yielded the best Scheimpflug results (AUC 0.86, sensitivity 83%, specificity 83%). Combining 11 SD OCT thickness metrics (minimum-median, temporal outer, superior nasal outer, minimum, epithelium minimum-maximum, epithelial standard deviation, superior inner, superior outer, superior temporal outer, superior nasal inner, central) yielded the best SD OCT results (AUC 0.96, sensitivity 89%, specificity 89%). Combining 13 total Scheimpflug/SD OCT metrics yielded the best results overall (AUC 1.0, sensitivity 100%, specificity 100%). The most impactful variables in combined models included epithelial thickness variability and total focal corneal thickness variability from SD OCT and anterior curvature and topometric indices from Scheimpflug technology. No posterior corneal metrics were impactful in modeling. CONCLUSIONS Individual machine-derived metrics from Scheimpflug and SD OCT imaging poorly distinguished normal eyes from minimally affected eyes from patients with highly AKC. Combined SD OCT metrics performed better than combined Scheimpflug metrics. Combining anterior curvature and asymmetry indices from Scheimpflug with regional total thickness and epithelial thickness variability metrics from SD OCT clearly distinguished the 2 populations. Posterior corneal indices were not useful in distinguishing populations.
Collapse
Affiliation(s)
- Eric S Hwang
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | | | - Sang Woo Kim
- Department of Ophthalmology, Ulsan University of College of Medicine, Ulsan, South Korea
| | - Marcony R Santhiago
- USC Roski Eye Institute, Los Angeles, California; Department of Ophthalmology at University of Sao Paulo, Sao Paulo, Brazil; Department of Ophthalmology at Federal University of Rio de Janeiro, Sao Paulo, Brazil
| | - J Bradley Randleman
- Keck School of Medicine of the University of Southern California, Los Angeles, California; USC Roski Eye Institute, Los Angeles, California.
| |
Collapse
|