1
|
Li Y, Lu F, Yi P, Zou Z, Zhang X, Zhang J. Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study. Proc Inst Mech Eng H 2024; 238:897-908. [PMID: 39180409 DOI: 10.1177/09544119241272782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/26/2024]
Abstract
The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area.At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.
Collapse
Affiliation(s)
- Yafeng Li
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Fengyuan Lu
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Peng Yi
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Zichun Zou
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Xi Zhang
- Traumatic Orthopedics, Tianjin Hospital, Tianjin, China
| | - Jing Zhang
- Department of Mechanical and Energy Engineering, Indiana University-Purdue University Indianapolis, IN, USA
| |
Collapse
|
2
|
Jian Z, Jiang X, Li D, Zhou J, Yu B, Yi C. Finite element analysis of a novel anatomical plate in posterolateral plateau fractures. Front Surg 2024; 11:1346462. [PMID: 39077678 PMCID: PMC11284072 DOI: 10.3389/fsurg.2024.1346462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 07/01/2024] [Indexed: 07/31/2024] Open
Abstract
Objective This study aims to analyze the biomechanical characteristics of posterolateral plateau fractures fixed by a novel anatomical plate using finite element analysis. Methods A three-dimensional digital model of the full length of right tibiofibula was obtained by CT scanning. A posterolateral tibial plateau fracture model was then created. The acquired fracture model was assembled with 4 groups of internal fixations: Group A, novel anatomical plate; Group B, straight buttress plate; Group C, oblique T-shaped locking plate; Group D, two lag screws. Axial loads of 500, 1,000 and 1,500 N perpendicular to the horizontal plane were used to simulate the stress on the lateral plateau of a 65 kg person standing, walking and fast running. Results Vertical displacements of the posterolateral fragments in each of the four groups gradually increased under loads from 500 N to 1,500 N. The maximum displacement of the fracture fragment in four groups were all located on the lateral side of the proximal part, and the displacement gradually decreased from the proximal part to the distal end. The maximum displacement values under the axial load of 1,500 N was in the following order: novel anatomical plate (1.2365 mm) < oblique T-shaped locking plate (1.314 mm) < two lag screws (1.3747 mm) < straight buttress plate (1.3932 mm). As the axial load increased, the stress value of the different internal fixation models gradually increased. The stress behavior of the same internal fixation model under different loads was similar. The maximum stress value under the axial load of 1,500 N was in the following order: novel anatomical plate (114.63 MPa) < oblique T-shaped locking plate (277.17 MPa) < two lag screws (236.75 MPa) < straight buttress plate (136.2 MPa). Conclusion The patients with posterolateral plateau fractures fixed with a novel anatomical plate in standing, walking and fast running can achieve satisfactory biomechanical results, which lays the foundation for future applications. At the same time, clinical fracture types are often diverse and accompanied by damage to the soft tissue. Therefore, the ideal surgical approach and appropriate internal fixation must be selected based on the patient's injury condition.
Collapse
Affiliation(s)
- Zhen Jian
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Xinhua Jiang
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Dejian Li
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Jianhua Zhou
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Baoqing Yu
- Department of Orthopedics, Seventh People's Hospital of Shanghai, Shanghai, China
| | - Chengqing Yi
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| |
Collapse
|
3
|
Yan Z, Zou C, Kenmegne GR, Pan X, Ghimire N, Silva KMN, Fang Y. Newly designed plate for the treatment of posterolateral tibial plateau fractures: a finite element analysis. J Orthop Surg Res 2024; 19:201. [PMID: 38532441 DOI: 10.1186/s13018-024-04686-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Accepted: 03/16/2024] [Indexed: 03/28/2024] Open
Abstract
BACKGROUND This study investigated the biomechanical properties of a new plate used for the treatment of posterolateral tibial plateau fractures using finite element analysis. METHODS The study groups were as follows: group PM, model of the new plate with posteromedial tibial plateau fracture; group PL, model of the new plate with posterolateral tibial plateau fracture; and group PC, model of the new plate with posterior tibial plateau fracture. We used two loading modes: uniform loading on the entire plateau, and loading on the posterior plateau. Data such as the displacement of the fracture and distribution of stress on the new plate and screws were recorded and analyzed. RESULTS When the whole plateau was loaded, the displacement of fractures in groups PM, PL, and PC were 0.273, 0.114, and 0.265 mm, respectively. The maximum stresses on the plates in groups PM, PL, and PC were 118.131 MPa, 44.191 MPa, and 115.433 MPa. The maximum stresses on the screws in Groups PM, PL, and PC were 166.731, 80.330, and 164.439 MPa, respectively. When the posterior tibial plateau was loaded, the displacement of the fractures in groups PM, PL, and PC was 0.410, 0.213, and 0.390 mm, respectively. The maximum stresses on the plates in groups PM, PL, and PC were 194.012 MPa, 72.806 MPa, and 185.535 MPa. The maximum stresses on the screws in Groups PM, PL, and PC were 278.265, 114.839, and 266.396 MPa, respectively. CONCLUSION The results of this study revealed that titanium plates have good fixation effects in all groups; therefore, the use of the new plate for posterolateral tibial plateau fractures appears to be safe and valid.
Collapse
Affiliation(s)
- Zhaokui Yan
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Chang Zou
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Guy Romeo Kenmegne
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Xuelin Pan
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Nawin Ghimire
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Kuruwitage Manthi Nihara Silva
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Yue Fang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China.
| |
Collapse
|
4
|
刘 家, 张 英, 郑 占. [Research progress on biomechanics for internal fixation in tibial plateau fracture]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2024; 38:113-118. [PMID: 38225850 PMCID: PMC10796227 DOI: 10.7507/1002-1892.202309077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/23/2023] [Accepted: 11/24/2023] [Indexed: 01/17/2024]
Abstract
Objective To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic. Methods The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed. Results Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures. Conclusion Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
Collapse
Affiliation(s)
- 家伦 刘
- 河北医科大学第三医院创伤急救中心(石家庄 050051)Department of Trauma Emergency Center, the Third Affiliated Hospital of Hebei Medical University, Shijiazhuang Hebei, 050051, P. R. China
| | - 英泽 张
- 河北医科大学第三医院创伤急救中心(石家庄 050051)Department of Trauma Emergency Center, the Third Affiliated Hospital of Hebei Medical University, Shijiazhuang Hebei, 050051, P. R. China
| | - 占乐 郑
- 河北医科大学第三医院创伤急救中心(石家庄 050051)Department of Trauma Emergency Center, the Third Affiliated Hospital of Hebei Medical University, Shijiazhuang Hebei, 050051, P. R. China
| |
Collapse
|
5
|
Zhang BB, Wang BH, Mei J, Luo CF, Zhu Y. Biomechanical study of a new rim plate fixation strategy for two kinds of posterolateral depression patterns of tibial plateau fractures: a finite element analysis. J Orthop Surg Res 2023; 18:840. [PMID: 37932801 PMCID: PMC10629018 DOI: 10.1186/s13018-023-04315-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 10/24/2023] [Indexed: 11/08/2023] Open
Abstract
PURPOSE The biomechanical capacity of "Barrel Hoop Plate (BHP)" in the treatment of the posterolateral tibial plateau (PL) depression fractures remains unknown. In this study, two kinds of posterolateral tibial plateau depression models involving mild slope-type depression fracture (MSDF) and local sink hole-type depression fracture (LSDF) were created to test and compare the biomechanical capacities of BHP with the other two conventional fixations (Anterolateral Plate and Posterolateral Plate, ALP and PLP) by finite element analysis. METHODS The 3D models of three kinds of plate-screw systems and the two kinds of PL-depression models (MSDF and LSDF) were created. An axial force of 400N was applied from the distal femur to the tibial plateau. The maximal displacements of the posterolateral fractures (PLFs), the distribution on the PLFs articular surface and key points displacements were measured. Stresses in the fixation complex including the maximal Equivalent (von-Mises) Stress of implants, the max shear stress of PLFs and stiffness of the fixation were calculated. RESULTS The maximal displacement of MSDF was least in Group BHP. The maximal displacement of LSDF was least in Group ALP. In MSDF, BHP showed the best rim fix effect in MSDF, but unsatisfactory results in LSDF. In both MSDF and LSDF, the greatest max Equivalent Stress of the plate and the screw occurred in the PLP system. ALP and BHP showed a comparable stiffness in MSDF and ALP had the strongest stiffness in the fixation of LSDF. CONCLUSIONS In MSDF, the BHP has the best biomechanical capacity, especially in displacements of key points such as the PL rim, fracture line, and depression center. In LSDF, the ALP system shows the best biomechanical effect. Although the PLP has the best fixation effect on the posterior wall, it is not suitable for PL-depression fracture fixation.
Collapse
Affiliation(s)
- Bin-Bin Zhang
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China
| | - Bing-Hao Wang
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China
| | - Jiong Mei
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
| | - Cong-Feng Luo
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
| | - Yi Zhu
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
| |
Collapse
|
6
|
Zhu B, Chen J, Zhang Y, Song L, Fang J. Revisiting the flexion-valgus type unicondylar posterolateral tibial plateau depression fracture pattern: classification and treatment. J Orthop Surg Res 2023; 18:825. [PMID: 37919777 PMCID: PMC10621237 DOI: 10.1186/s13018-023-04318-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 10/24/2023] [Indexed: 11/04/2023] Open
Abstract
OBJECTIVE This study aimed to reclassify posterolateral tibial plateau fractures caused by a flexion-valgus force and describe this fracture pattern to provide a relatively programmed surgical treatment based on morphological characteristics that may improve reduction and stabilization. METHODS We retrospectively reviewed the fracture pattern and injury mechanism of patients with posterolateral tibial plateau fractures who underwent surgery at the First Affiliated Hospital of Nanjing Medical University between January 2014 and April 2020. The cohort was divided into three types. Type I was a depression fracture of the posterolateral platform with an intact posterolateral cortex. Type II was a depression fracture of the posterolateral platform with a disrupted posterolateral cortex. Type III was a depression fracture of the posterolateral platform in combination with anterior cruciate ligament (ACL) rupture or tibial insertion avulsion fracture of the ACL. The lateral window of the modified Frosch approach with an L-type locking plate was used for patients with type I and type III fractures. For patients with type II fractures, both lateral and posterolateral windows of the modified Frosch approach were used for surgery, and a T-plate on the posterior side with an L-plate on the lateral side were used for fixation. The Rasmussen radiology scoring was used to evaluate the quality of surgical reduction and the Rasmussen functional scoring evaluation standard was used to evaluate knee joint function. RESULTS A total of 69 tibial plateau fractures (36 male, 33 female) involving the posterolateral platform were discovered and included in this study. All patients suffered flexion-valgus force at the moment of the accident. There were 32 cases of Type I fracture, 28 cases of Type II fracture, and 9 cases of Type III fracture. The patients were followed up for 12-30 (mean 20.8 ± 9.4) months. The postoperative Rasmussen radiological scores for the three types of fractures were 15-17 (mean 16.31 ± 0.78), 14-17 (mean 15.93 ± 0.94), and 14-17 (mean 16.22 ± 0.97), respectively. The postoperative Rasmussen functional scores for the three types of fractions were 27-30 (mean 27.97 ± 0.90), 27-29 (mean 27.36 ± 0.56), and 27-29 (mean 27.56 ± 0.73), respectively. CONCLUSION Flexion-valgus posterolateral tibial plateau fractures were divided into three types based on the integrity of the posterolateral wall and ACL injuries. We hope the classification can play a certain reference role in recognizing and treating flexion-valgus-type posterolateral tibial plateau fractures.
Collapse
Affiliation(s)
- Bin Zhu
- Department of Orthopaedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Jian Chen
- Department of Orthopaedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Yu Zhang
- Department of Orthopaedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Lijun Song
- Department of Orthopaedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Jiahu Fang
- Department of Orthopaedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
| |
Collapse
|
7
|
Wei G, Niu X, Li Y, Chang T, Zhang J, Wang H, Li X, He Y, Wang R, Tian F, Xu Y. Biomechanical analysis of internal fixation system stability for tibial plateau fractures. Front Bioeng Biotechnol 2023; 11:1199944. [PMID: 37388773 PMCID: PMC10303893 DOI: 10.3389/fbioe.2023.1199944] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 06/06/2023] [Indexed: 07/01/2023] Open
Abstract
Background: Complex bone plateau fractures have been treated with bilateral plate fixation, but previous research has overemphasized evaluating the effects of internal fixation design, plate position, and screw orientation on fracture fixation stability, neglecting the internal fixation system's biomechanical properties in postoperative rehabilitation exercises. This study aimed to investigate the mechanical properties of tibial plateau fractures after internal fixation, explore the biomechanical mechanism of the interaction between internal fixation and bone, and make suggestions for early postoperative rehabilitation and postoperative weight-bearing rehabilitation. Methods: By establishing the postoperative tibia model, the standing, walking and running conditions were simulated under three axial loads of 500 N, 1000 N, and 1500 N. Accordingly, finite element analysis (FEA) was performed to analyze the model stiffness, displacement of fractured bone fragments, titanium alloy plate, screw stress distribution, and fatigue properties of the tibia and the internal fixation system under various conditions. Results: The stiffness of the model increased significantly after internal fixation. The anteromedial plate was the most stressed, followed by the posteromedial plate. The screws at the distal end of the lateral plate, the screws at the anteromedial plate platform and the screws at the distal end of the posteromedial plate are under greater stress, but at a safe stress level. The relative displacement of the two medial condylar fracture fragments varied from 0.002-0.072 mm. Fatigue damage does not occur in the internal fixation system. Fatigue injuries develop in the tibia when subjected to cyclic loading, especially when running. Conclusion: The results of this study indicate that the internal fixation system tolerates some of the body's typical actions and may sustain all or part of the weight early in the postoperative period. In other words, early rehabilitative exercise is recommended, but avoid strenuous exercise such as running.
Collapse
Affiliation(s)
- Guoqiang Wei
- Department of Rehabilitation Medicine, Changzhi Medical College Affiliated Changzhi People’s Hospital, Changzhi, China
| | - Xiaofen Niu
- Department of Rehabilitation Medicine, Changzhi Medical College Affiliated Changzhi People’s Hospital, Changzhi, China
| | - Yuan Li
- Department of Orthopedics, Changzhi Medical College Affiliated Peace Hospital, Changzhi, China
| | - Tingjie Chang
- Department of Orthopedics, Changzhi Medical College Affiliated Peace Hospital, Changzhi, China
| | - Jianfang Zhang
- Department of Rehabilitation Medicine, Changzhi Medical College Affiliated Changzhi People’s Hospital, Changzhi, China
| | - Haiyan Wang
- Department of Anatomy, School of Basic Medical Sciences, Inner Mongolia Medical University, Hohhot, China
| | - Xiaohe Li
- Department of Anatomy, School of Basic Medical Sciences, Inner Mongolia Medical University, Hohhot, China
| | - Yujie He
- Department of Anatomy, School of Basic Medical Sciences, Inner Mongolia Medical University, Hohhot, China
| | - Ruijiang Wang
- Department of Orthopedics, Changzhi Second People’s Hospital, Changzhi, China
| | - Fei Tian
- Department of Health Management, Changzhi Medical College, Changzhi, China
- Department of Rehabilitation Medicine, Changzhi Medical College Affiliated Peace Hospital, Changzhi, China
| | - Yangyang Xu
- Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable and Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
8
|
Yan B, Huang X, Xu Y, Zou C. A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis. Orthop Surg 2023; 15:1104-1116. [PMID: 36793219 PMCID: PMC10102290 DOI: 10.1111/os.13660] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 12/16/2022] [Accepted: 12/23/2022] [Indexed: 02/17/2023] Open
Abstract
OBJECTIVE The complex tibial plateau fractures involving both medial and posterolateral columns are of frequent occurrence in clinics, but the existing fixation system cannot deal with medial and posterolateral fragments simultaneously. Therefore, a novel locking buttress plate named as medial and posterior column plate (MPCP) was designed in this study to fix the simultaneous medial and posterolateral tibial plateau fractures. Meanwhile, the comparative finite element analysis (FEA) was conducted to investigate the discrepancy between MPCP and traditional multiple plates (MP + PLP) in their biomechanical characteristics. METHODS Two 3D finite element models of simultaneous medial and posterolateral tibial plateau fracture fixed with MPCP and MP + PLP system, respectively, was constructed. To imitate the axial stress of knee joint in ordinary life, diverse axial forces with 100, 500, 1000, and 1500 N were applied in the two fixation models, and then the equivalent displacement and stress nephograms and values were obtained. RESULTS The similar trend of displacement and stress increasing with the loads was observed in the two fixation models. However, several heterogeneities of displacement and stress distribution were found in the two fixation models. The max displacement and von Mises stress values of plates, screws, and fragments in the MPCP fixation model were significantly smaller than that in the MP + PLP fixation model, except for the max-shear stress values. CONCLUSION As a single locking buttress plate, the MPCP system showed the excellent benefit on improving the stability of the simultaneous medial and posterolateral tibial plateau fractures, compared with the traditional double plate fixation system. However, the excessive shear stress around screw holes should be paid attention to prevent trabecular microfracture and screw loosening.
Collapse
Affiliation(s)
- Bangji Yan
- Department of Orthopaedics and TraumatologyCixi Hospital of Traditional Chinese MedicineNingboChina
| | - Xiaotao Huang
- Department of Orthopaedics and TraumatologyCixi Hospital of Traditional Chinese MedicineNingboChina
| | - Yingxing Xu
- Department of Trauma CenterFirst Affiliated Hospital of Kunming Medical UniversityKunmingChina
| | - Chengshi Zou
- Department of RadiologyCixi Hospital of Traditional Chinese MedicineNingboChina
| |
Collapse
|
9
|
Hu S, Li S, Chang S, Du S, Xiong W. Surgical exposure to posterolateral quadrant tibial plateau fractures: an anatomic comparison of posterolateral and posteromedial approaches. J Orthop Surg Res 2022; 17:346. [PMID: 35841047 PMCID: PMC9284737 DOI: 10.1186/s13018-022-03236-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 06/25/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Management of posterolateral tibial plateau quadrant fractures can be challenging, and two posterior approaches were frequently used for exposure, reduction, and fixation: posterolateral approach and posteromedial approach. The purpose of this study was to compare their deep anatomical structure and analyze their limits and the risk of injury to important structures during surgical dissection of two approaches. METHOD Five lower limb specimens were used in this study. After dissection of the skin and superficial fascia of each specimen, deep structures were dissected via posteromedial and posterolateral approach, and several parameters including perpendicular distance from the anterior tibial artery coursing through the interosseous membrane fissure to the lateral joint line and apex of fibular head and so on were measured and analyzed. RESULT The perpendicular distance from the ATA coursing through the interosseous membrane fissure to the lateral joint line was 49.3 ± 5.6 mm (range 41.3-56.7 mm), while the distance to the apex of fibular head was 37.7 ± 7.2 mm (range 29.0-48.0 mm). The transverse distance of the anterior tibial vascular bundle is around 10 mm. The perpendicular distance from the top accompanying vein of the ATA bundle to lateral joint line and apex of fibular head was 44.1 ± 6.3 mm and 32.5 ± 7.6 mm, respectively. The maximum proportion of posterolateral tibial plateau shielded by the fibular head from the posterior view was 61.7 ± 4.9% (range 55.6-64.1%). The average length of popliteus muscle outside the joint was 83.1 ± 6.0 mm (range 76.5-92.2 mm), and the width in the middle was 28.1 ± 4.3 mm (range 26.6-29.1 mm). CONCLUSION Although posterolateral approach seems more direct for exposure of posterolateral quadrant tibial plateau fracture, it has three major disadvantages in deep dissection. Posteromedial approach through the medial board of medial head of gastrocnemius-soleus may be safer, but it was hard for direct visualization of articular surface which limits it usage for only a few cases.
Collapse
Affiliation(s)
- Sunjun Hu
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, 450 Tengyue Road, Shanghai, 200090, People's Republic of China
| | - Shijie Li
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, 450 Tengyue Road, Shanghai, 200090, People's Republic of China
| | - Shimin Chang
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, 450 Tengyue Road, Shanghai, 200090, People's Republic of China.
| | - Shouchao Du
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, 450 Tengyue Road, Shanghai, 200090, People's Republic of China
| | - Wenfeng Xiong
- Department of Orthopedic Surgery, Yangpu Hospital, Tongji University School of Medicine, 450 Tengyue Road, Shanghai, 200090, People's Republic of China
| |
Collapse
|
10
|
Ferre LS, Di Nisio FG, Mendonça CJA, Belo IM. Comparative analysis of tibial plateau fracture osteosynthesis: A finite element study. J Mech Behav Biomed Mater 2022; 134:105392. [DOI: 10.1016/j.jmbbm.2022.105392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 02/12/2022] [Accepted: 07/19/2022] [Indexed: 11/16/2022]
|
11
|
A finite element analysis of relationship between fracture, implant and tibial tunnel. Sci Rep 2021; 11:1781. [PMID: 33469082 PMCID: PMC7815705 DOI: 10.1038/s41598-021-81401-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Accepted: 01/06/2021] [Indexed: 01/14/2023] Open
Abstract
The purpose of this article was to use finite element analysis (FEA) to study the relationship of tibial tunnel (TT) with fracture pattern and implants. A computed tomography scan of full-length tibia and fibula was obtained. Models were built after three-dimensional reconstruction. The corresponding plates and screws were constructed and assembled together with fracture models. FEA was performed and contourplots were output. The Von Mises stresses of nodes and displacements of elements were extracted. Student’s t test was used to compare the values of Von Mises stresses and displacements between corresponding models. Differences in Von Mises stresses and displacements of fragments and implants between models with and without TT were nearly all statistically significant. However, the displacements of fragments and implants for all models were < 2 mm. TT in fracture models had larger Von Mises stresses than TT in intact tibial model. However, displacements of TT in fracture models showed similar or even smaller results to those in intact tibial model. Although almost all the tested parameters were statistically significant, differences were small and values were all below the clinical threshold. This study could promote open reduction and internal fixation with one-stage reconstruction for treatment of tibial plateau fractures associated with anterior cruciate ligament (ACL) ruptures.
Collapse
|
12
|
Finite element analysis of Bi-condylar Tibial Plateau fractures to assess the effect of coronal splits. Med Eng Phys 2020; 84:84-95. [DOI: 10.1016/j.medengphy.2020.07.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 06/08/2020] [Accepted: 07/26/2020] [Indexed: 11/21/2022]
|
13
|
Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10144941] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bone interface. A Schatzker type I tibial fracture was considered, and four different screw configurations were investigated. The obtained results demonstrated that, for this specific case study, screw orientation affected the pressure distribution at the screw/bone interface. The proposed approach could be used effectively to investigate different fracture types in order to give orthopaedists useful guidelines for the treatment of proximal tibial fractures.
Collapse
|
14
|
Ozturk AM, Suer O, Derin O, Ozer MA, Govsa F, Aktuglu K. Surgical advantages of using 3D patient-specific models in high-energy tibial plateau fractures. Eur J Trauma Emerg Surg 2020; 46:1183-1194. [DOI: 10.1007/s00068-020-01378-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Accepted: 04/20/2020] [Indexed: 01/17/2023]
|
15
|
Quintens L, Herteleer M, Vancleef S, Carette Y, Duflou J, Nijs S, Sloten JV, Hoekstra H. Anatomical Variation of the Tibia - a Principal Component Analysis. Sci Rep 2019; 9:7649. [PMID: 31114000 PMCID: PMC6529455 DOI: 10.1038/s41598-019-44092-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 05/07/2019] [Indexed: 12/17/2022] Open
Abstract
Conventional anatomically contoured plates do not adequately fit most tibiae. This emphasizes the need for a more thorough morphological study. Statistical shape models are promising tools to display anatomical variations within a population. Herein, we aim to provide a better insight into the anatomical variations of the tibia and tibia plateau. Seventy-nine CT scans of tibiae were segmented, and a principal component analysis was performed. Five morphologically important parameters were measured on the 3D models of the mean tibial shapes as well as the −3SD and +3 SD tibial shapes of the first five components. Longer, wider tibiae are related to a more rounded course of the posterior column, a less prominent tip of the medial malleolus, and a more posteriorly directed fibular notch. Varus/valgus deformations and the angulation of the posterior tibia plateau represent only a small percentage of the total variation. Right and left tibiae are not always perfectly symmetrical, especially not at the level of the tibia plateau. The largest degree of anatomical variation of the tibia is found in its length and around the tibia plateau. Because of the large variation in the anatomy, a more patient-specific approach could improve implant fit, anatomical reduction, biomechanical stability and hardware-related complications.
Collapse
Affiliation(s)
- Liselore Quintens
- KU Leuven - University of Leuven, Faculty of Medicine, Leuven, Belgium
| | - Michiel Herteleer
- Department of Trauma Surgery, University Hospitals Leuven, Leuven, Belgium.,Biomedical Science Group, Organ Systems, KU Leuven - University of Leuven, Leuven, Belgium
| | - Sanne Vancleef
- Department of Mechanical Engineering, KU Leuven - University of Leuven, Leuven, Belgium
| | - Yannick Carette
- Department of Mechanical Engineering, KU Leuven - University of Leuven, Leuven, Belgium
| | - Joost Duflou
- Department of Mechanical Engineering, KU Leuven - University of Leuven, Leuven, Belgium
| | - Stefaan Nijs
- Department of Trauma Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Development and Regeneration, KU Leuven - University of Leuven, Leuven, Belgium
| | - Jos Vander Sloten
- Department of Mechanical Engineering, KU Leuven - University of Leuven, Leuven, Belgium
| | - Harm Hoekstra
- Department of Trauma Surgery, University Hospitals Leuven, Leuven, Belgium. .,Department of Development and Regeneration, KU Leuven - University of Leuven, Leuven, Belgium.
| |
Collapse
|
16
|
Belaid D, Vendeuvre T, Bouchoucha A, Brémand F, Brèque C, Rigoard P, Germaneau A. Utility of cement injection to stabilize split-depression tibial plateau fracture by minimally invasive methods: A finite element analysis. Clin Biomech (Bristol, Avon) 2018; 56:27-35. [PMID: 29777960 DOI: 10.1016/j.clinbiomech.2018.05.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 04/16/2018] [Accepted: 05/04/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Treatment for fractures of the tibial plateau is in most cases carried out by stable fixation in order to allow early mobilization. Minimally invasive technologies such as tibioplasty or stabilization by locking plate, bone augmentation and cement filling (CF) have recently been used to treat this type of fracture. The aim of this paper was to determine the mechanical behavior of the tibial plateau by numerically modeling and by quantifying the mechanical effects on the tibia mechanical properties from injury healing. METHODS A personalized Finite Element (FE) model of the tibial plateau from a clinical case has been developed to analyze stress distribution in the tibial plateau stabilized by balloon osteoplasty and to determine the influence of the cement injected. Stress analysis was performed for different stages after surgery. FINDINGS Just after surgery, the maximum von Mises stresses obtained for the fractured tibia treated with and without CF were 134.9 MPa and 289.9 MPa respectively on the plate. Stress distribution showed an increase of values in the trabecular bone in the treated model with locking plate and CF and stress reduction in the cortical bone in the model treated with locking plate only. INTERPRETATION The computed results of stresses or displacements of the fractured models show that the cement filling of the tibial depression fracture may increase implant stability, and decrease the loss of depression reduction, while the presence of the cement in the healed model renders the load distribution uniform.
Collapse
Affiliation(s)
- D Belaid
- Department of Mechanical Engineering, Faculty of Technology Sciences, University of Mentouri Brothers - Constantine, P.O. Box 325, Ain-El-Bey Way, Constantine 25017, Algeria; Institut Pprime UPR 3346, CNRS - Université de Poitiers - ISAE-ENSMA, Poitiers, France
| | - T Vendeuvre
- Institut Pprime UPR 3346, CNRS - Université de Poitiers - ISAE-ENSMA, Poitiers, France; Department of Orthopaedic Surgery and Traumatology, CHU Poitiers, Poitiers, France; Spine & neuromodulation functional unit, Department of neurosurgery, CHU Poitiers, PRISMATICS Lab, Poitiers, France
| | - A Bouchoucha
- Department of Mechanical Engineering, Faculty of Technology Sciences, University of Mentouri Brothers - Constantine, P.O. Box 325, Ain-El-Bey Way, Constantine 25017, Algeria
| | - F Brémand
- Institut Pprime UPR 3346, CNRS - Université de Poitiers - ISAE-ENSMA, Poitiers, France
| | - C Brèque
- Institut Pprime UPR 3346, CNRS - Université de Poitiers - ISAE-ENSMA, Poitiers, France; ABS Lab, Université de Poitiers, France
| | - P Rigoard
- Institut Pprime UPR 3346, CNRS - Université de Poitiers - ISAE-ENSMA, Poitiers, France; Spine & neuromodulation functional unit, Department of neurosurgery, CHU Poitiers, PRISMATICS Lab, Poitiers, France
| | - A Germaneau
- Institut Pprime UPR 3346, CNRS - Université de Poitiers - ISAE-ENSMA, Poitiers, France.
| |
Collapse
|
17
|
Sun H, He QF, Zhang BB, Zhu Y, Zhang W, Chai YM. A biomechanical evaluation of different fixation strategies for posterolateral fragments in tibial plateau fractures and introduction of the 'magic screw'. Knee 2018; 25:417-426. [PMID: 29678367 DOI: 10.1016/j.knee.2018.03.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 02/28/2018] [Accepted: 03/26/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Posterior plate fixation is biomechanically the strongest fixation method for posterolateral column fracture (PLCF) of the tibial plateau; however, there are inherent deficiencies and risks of a posterior approach. Thus, the 'magic screw' was proposed to enhance fixation stability of the lateral rafting plate used for PLCF. The purpose of this study was to re-examine and compare the stability of different fixation methods for PLCF. METHODS Synthetic tibiae models were used to simulate posterolateral split fractures. The fracture models were randomly assigned into three groups: Group A, fixed with posterolateral buttress plates; Group B, with lateral locking compression plates (LCP); and Group C fixed with lateral LCPs and one 'magic screw'. Gradually increased axial compressive loads were applied to each specimen. RESULTS There was a mean subsidence hierarchy of the posterolateral fragment at different load levels: Group A had the least subsidence, followed by Group C, and Group B had the most. There were no significant differences in the mean loads at different displacements between Group A and Group C. Group A had the highest axial stiffness. Additionally, there was a significant difference in axial stiffness between Group B and Group C. CONCLUSION Biomechanical stability of the combined fixation of the posteriorly positioned lateral rafting plate with the 'magic screw' was much closer to that of posterior plate fixation for split-type PLCF. The necessity of posterior fixation through a posterior approach may be reduced for selected patients.
Collapse
Affiliation(s)
- Hui Sun
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Qi-Fang He
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Bin-Bin Zhang
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Yi Zhu
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Wei Zhang
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
| | - Yi-Min Chai
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
| |
Collapse
|
18
|
Chen F, Huang X, Ya Y, Ma F, Qian Z, Shi J, Guo S, Yu B. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures. J Orthop Surg Res 2018; 13:12. [PMID: 29338748 PMCID: PMC5771144 DOI: 10.1186/s13018-017-0707-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 12/26/2017] [Indexed: 11/18/2022] Open
Abstract
Background Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. Methods A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. Results The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P < 0.0001). The maximal value of displacement (sum) in the IMN system was 8.82 mm, which was lower than that in the DLP fixation system (9.48 mm). Conclusions This study demonstrated that the stability provided by the locking plate fixation system was superior to the intramedullary nails fixation system and served as an alternative fixation for the extra-articular proximal tibial fractures of young patients.
Collapse
Affiliation(s)
- Fancheng Chen
- Shanghai Medical College, Fudan University, Shanghai City, China
| | - Xiaowei Huang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Yingsun Ya
- Shanghai Medical College, Fudan University, Shanghai City, China
| | - Fenfen Ma
- Department of Pharmacy, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai City, China
| | - Zhi Qian
- Shanghai Medical College, Fudan University, Shanghai City, China
| | - Jifei Shi
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, No.2800 gongwei road, Huinan town, Pudong new area, Shanghai City, China
| | - Shuolei Guo
- Shanghai Medical College, Fudan University, Shanghai City, China
| | - Baoqing Yu
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, No.2800 gongwei road, Huinan town, Pudong new area, Shanghai City, China.
| |
Collapse
|