1
|
Rix A, Heinrichs H, Porte C, Leenaars C, Bleich A, Kiessling F. Ultrasound-induced immune responses in tumors: A systematic review and meta-analysis. J Control Release 2024; 371:146-157. [PMID: 38777126 DOI: 10.1016/j.jconrel.2024.05.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 04/29/2024] [Accepted: 05/17/2024] [Indexed: 05/25/2024]
Abstract
Ultrasound is widely used in the diagnosis and therapy of cancer. Tumors can be treated by thermal or mechanical tissue ablation. Furthermore, tumors can be manipulated by hyperthermia, sonodynamic therapy and sonoporation, e.g., by increasing tumor perfusion or the permeability of biological barriers to enhance drug delivery. These treatments induce various immune responses in tumors. However, conflicting data and high heterogeneity between experimental settings make it difficult to generalize the effects of ultrasound on tumor immunity. Therefore, we performed a systematic review to answer the question: "Does ultrasound alter the immune reaction of peripheral solid tumors in humans and animals compared to control conditions without ultrasound?" A systematic literature search was performed in PubMed, EMBASE, and Web of Science and 24,401 potentially relevant publications were identified. Of these, 96 publications were eligible for inclusion in the systematic review. Experiments were performed in humans, rats, and mice and focused on different tumor types, primarily breast and melanoma. We collected data on thermal and non-thermal ultrasound settings, the use of sono-sensitizers or sono-enhancers, and anti-tumor therapies. Six meta-analyses were performed to quantify the effect of ultrasound on tumor infiltration by T cells (cytotoxic, helper, and regulatory T cells) and on blood cytokines (interleukin-6, interferon-γ, tumor necrosis factor-α). We provide robust scientific evidence that ultrasound alters T cell infiltration into tumors and increases blood cytokine concentrations. Furthermore, we identified significant differences in immune cell infiltration based on tumor type, ultrasound settings, and mouse age. Stronger effects were observed using hyperthermia in combination with sono-sensitizers and in young mice. The latter may impair the translational impact of study results as most cancer patients are older. Thus, our results may help refining ultrasound parameters to enhance anti-tumor immune responses for therapeutic use and to minimize immune effects in diagnostic applications.
Collapse
Affiliation(s)
- Anne Rix
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Helen Heinrichs
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Céline Porte
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Cathalijn Leenaars
- Institute for Laboratory Animal Science, Hannover Medical School, Hannover, Germany
| | - André Bleich
- Institute for Laboratory Animal Science, Hannover Medical School, Hannover, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen University, Aachen, Germany; Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany.
| |
Collapse
|
2
|
Rix A, Girbig R, Porte C, Lederle W, Leenaars C, Kiessling F. Development of a Systematic Review Protocol and a Scoping Review of Ultrasound-Induced Immune Effects in Peripheral Tumors. Mol Imaging Biol 2022; 24:288-297. [PMID: 34845660 PMCID: PMC8983530 DOI: 10.1007/s11307-021-01686-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 11/02/2021] [Accepted: 11/11/2021] [Indexed: 12/09/2022]
Abstract
PURPOSE Publication numbers reporting that ultrasound can stimulate immune reactions in tumors steadily increase. However, the presented data are partially conflicting, and mechanisms are difficult to identify from single publications. These shortcomings can be addressed by a systematic review and meta-analysis of current literature. As a first step, we here present the methodology and protocol for a systematic review to answer the following research question: Does ultrasound alter the immune reaction of peripheral solid tumors in humans and animals compared to control conditions without ultrasound? PROCEDURES We designed a protocol to perform a systematic review and meta-analysis. The suitability of the protocol to detect and sort relevant literature was tested using a subset of publications. We extracted study characteristics, ultrasound parameters, and study outcomes to pre-evaluate the differences between publications and present the data as a scoping review. RESULTS From 6532 publications detected by our preliminary literature search, 320 were selected for testing our systematic review protocol. Of the latter, 15 publications were eligible for data extraction. There, we found large differences between study characteristics (e.g., tumor type, age) and ultrasound settings (e.g., wavelength 0.5-9.5 MHz, acoustic pressure 0.0001-15,000 W/cm2). Finally, study outcomes included reports on cells of the innate (e.g., dendritic cells, macrophages) and adaptive immune system (e.g., CD8-/CD4-positive T cells). CONCLUSION We designed a protocol to identify relevant literature and perform a systematic review and meta-analysis. The differences between extracted features between publications show the necessity for a comprehensive search and selection strategy in the systematic review to get a complete overview of the literature. Meta-analyses of the extracted outcomes can then enable evidence-based conclusions.
Collapse
Affiliation(s)
- Anne Rix
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Aachen, Germany.
| | - Renée Girbig
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Aachen, Germany
| | - Céline Porte
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Aachen, Germany
| | - Wiltrud Lederle
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Aachen, Germany
| | - Cathalijn Leenaars
- Department for Health Evidence, Radboud Institute for Health Sciences, Radboud University Medical Centre, 6525 GA, Nijmegen, The Netherlands
- Department of Population Health Science, Unit Animals in Science and Society, Utrecht University, 3508 TD, Utrecht, The Netherlands
- Institute for Laboratory Animal Science, Hannover Medical School, 30625, Hannover, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Aachen, Germany
| |
Collapse
|
3
|
Coiado OC, Lowe J, O'Brien WD. Therapeutic Ultrasound in Cardiovascular Medicine. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 40:1061-1076. [PMID: 32964505 DOI: 10.1002/jum.15493] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 07/20/2020] [Accepted: 08/08/2020] [Indexed: 06/11/2023]
Abstract
An advantage of therapeutic ultrasound (US) is the ability to cause controlled biological effects noninvasively. Depending on the magnitude and frequency of exposure parameters, US can interact in different ways with a variety of biological tissues. The development and clinical utility of therapeutic US techniques are now rapidly growing, especially with regard to the application of US pulses for cardiac pacing and the potential treatment of cardiovascular diseases. This review outlines the basic principles of US-based therapy in cardiology, including the acoustic properties of the cardiovascular tissue, and the use of US in therapeutic cardiovascular medicine.
Collapse
Affiliation(s)
- Olivia C Coiado
- Department of Biomedical and Translational Sciences, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Jacques Lowe
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - William D O'Brien
- Bioacoustics Research Laboratory, Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| |
Collapse
|
4
|
Abstract
The use of contrast agents as signal enhancers during ultrasound improves visualization and the diagnostic utility of this technology in medical imaging. Although widely used in many disciplines, contrast ultrasound is not routinely implemented in obstetrics, largely due to safety concerns of administered agents for pregnant women and the limited number of studies that address this issue. Here the microbubble characteristics that make them beneficial for enhancement of the blood pool and the quantification of real-time imaging are reviewed. Literature from pregnant animal model studies and safety assessments are detailed, and the potential for contrast-enhanced ultrasound to provide clinically relevant data and benefit our understanding of early placental development and detection of placental dysfunction is discussed.
Collapse
|
5
|
Izadifar Z, Babyn P, Chapman D. Mechanical and Biological Effects of Ultrasound: A Review of Present Knowledge. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1085-1104. [PMID: 28342566 DOI: 10.1016/j.ultrasmedbio.2017.01.023] [Citation(s) in RCA: 154] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 01/26/2017] [Accepted: 01/30/2017] [Indexed: 05/12/2023]
Abstract
Ultrasound is widely used for medical diagnosis and increasingly for therapeutic purposes. An understanding of the bio-effects of sonography is important for clinicians and scientists working in the field because permanent damage to biological tissues can occur at high levels of exposure. Here the underlying principles of thermal mechanisms and the physical interactions of ultrasound with biological tissues are reviewed. Adverse health effects derived from cellular studies, animal studies and clinical reports are reviewed to provide insight into the in vitro and in vivo bio-effects of ultrasound.
Collapse
Affiliation(s)
- Zahra Izadifar
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
| | - Paul Babyn
- Department of Medical Imaging, Royal University Hospital, University of Saskatchewan and Saskatoon Health Region, Saskatoon, Saskatchewan, Canada
| | - Dean Chapman
- Anatomy & Cell Biology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| |
Collapse
|
6
|
Yoshida K, Obata K, Tsukamoto A, Ushida T, Watanabe Y. Limited damage of tissue mimic caused by a collapsing bubble under low-frequency ultrasound exposure. ULTRASONICS 2014; 54:1603-1609. [PMID: 24751130 DOI: 10.1016/j.ultras.2014.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Revised: 02/27/2014] [Accepted: 03/21/2014] [Indexed: 06/03/2023]
Abstract
In this study, we investigated the bubble induced serious damage to tissue mimic exposed to 27-kHz ultrasound. The initial bubble radius ranged from 80 to 100 μm, which corresponded approximately to the experimentally-evaluated resonant radius of the given ultrasound frequency. The tissue mimic consisted of 10 wt% gelatine gel covered with cultured canine kidney epithelial cells. The collapsing bubble behaviour during the ultrasound exposure with negative peak pressures of several hundred kPa was captured by a high-speed camera system. After ultrasound exposure, a cell viability test was conducted based on microscopic bright-field images and fluorescence images for living and dead cells. In the viability test, cells played a role in indicating the damaged area. The bubble oscillations killed the cells, and on occasion detached layers of cultured cells from the gel. The damaged area was comparable or slightly larger than the initial bubble size, and smaller than the maximum bubble size. We concluded that only a small area in close proximity to the bubble could be damaged even above transient cavitation threshold.
Collapse
Affiliation(s)
- Kenji Yoshida
- Laboratory of Ultrasonic Electronics, Doshisha University, 610-0321 Kyotanabe, Kyoto, Japan; Center for Frontier Medical Engineering, Chiba University, 263-8522 Chiba, Japan.
| | - Kazuya Obata
- Laboratory of Ultrasonic Electronics, Doshisha University, 610-0321 Kyotanabe, Kyoto, Japan
| | - Akira Tsukamoto
- Department of Applied Physics, National Defense Academy of Japan, 239-8686 Yokosuka, Kanagawa, Japan
| | - Takashi Ushida
- Center for Disease Biology and Integrative Medicine, The University of Tokyo, 113-0033 Bunkyo-ku, Tokyo, Japan
| | - Yoshiaki Watanabe
- Laboratory of Ultrasonic Electronics, Doshisha University, 610-0321 Kyotanabe, Kyoto, Japan
| |
Collapse
|
7
|
Lapchak PA, Kikuchi K, Butte P, Hölscher T. Development of transcranial sonothrombolysis as an alternative stroke therapy: incremental scientific advances toward overcoming substantial barriers. Expert Rev Med Devices 2014; 10:201-13. [DOI: 10.1586/erd.12.88] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
8
|
|
9
|
Abdelmoneim SS, Mulvagh SL. Perflutren lipid microsphere injectable suspension for cardiac ultrasound. ACTA ACUST UNITED AC 2012. [DOI: 10.2217/iim.12.11] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
10
|
Molina CA, Barreto AD, Tsivgoulis G, Sierzenski P, Malkoff MD, Rubiera M, Gonzales N, Mikulik R, Pate G, Ostrem J, Singleton W, Manvelian G, Unger EC, Grotta JC, Schellinger PD, Alexandrov AV. Transcranial ultrasound in clinical sonothrombolysis (TUCSON) trial. Ann Neurol 2009; 66:28-38. [PMID: 19670432 DOI: 10.1002/ana.21723] [Citation(s) in RCA: 164] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Microspheres (microS) reach intracranial occlusions and transmit energy momentum from an ultrasound wave to residual flow to promote recanalization. We report a randomized multicenter phase II trial of microS dose escalation with systemic thrombolysis. METHODS Stroke patients receiving 0.9mg/kg tissue plasminogen activator (tPA) with pretreatment proximal intracranial occlusions on transcranial Doppler (TCD) were randomized (2:1 ratio) to microS (MRX-801) infusion over 90 minutes (Cohort 1, 1.4ml; Cohort 2, 2.8ml) with continuous TCD insonation, whereas controls received tPA and brief TCD assessments. The primary endpoint was symptomatic intracerebral hemorrhage (sICH) within 36 hours after tPA. RESULTS Among 35 patients (Cohort 1 = 12, Cohort 2 = 11, controls = 12) no sICH occurred in Cohort 1 and controls, whereas 3 (27%, 2 fatal) sICHs occurred in Cohort 2 (p = 0.028). Sustained complete recanalization/clinical recovery rates (end of TCD monitoring/3 month) were 67%/75% for Cohort 1, 46%/50% for Cohort 2, and 33%/36% for controls (p = 0.255/0.167). The median time to any recanalization tended to be shorter in Cohort 1 (30 min; interquartile range [IQR], 6) and Cohort 2 (30 min; IQR, 69) compared to controls (60 min; IQR, 5; p = 0.054). Although patients with sICH had similar screening and pretreatment systolic blood pressure (SBP) levels in comparison to the rest, higher SBP levels were documented in sICH+ patients at 30 minutes, 60 minutes, 90 minutes, and 24-36 hours following tPA bolus. INTERPRETATION Perflutren lipid microS can be safely combined with systemic tPA and ultrasound at a dose of 1.4ml. Safety concerns in the second dose tier may necessitate extended enrollment and further experiments to determine the mechanisms by which microspheres interact with tissues. In both dose tiers, sonothrombolysis with microS and tPA shows a trend toward higher early recanalization and clinical recovery rates compared to standard intravenous tPA therapy. Ann Neurol 2009;66:28-38.
Collapse
Affiliation(s)
- Carlos A Molina
- Neurovascular Unit, Department of Neurology, Hospital Vall d'Hebron, Barcelona, Spain
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Abstract
The main mechanisms by which ultrasound can induce biological effects as it passes through the body are thermal and mechanical in nature. The mechanical effects are primarily related to the presence of gas, whether drawn out of solution by the negative going ultrasound pressure wave (acoustic cavitation), a naturally occurring gas body (such as lung alveoli), or deliberately introduced into the blood stream to increase imaging contrast (microbubble contrast agents). Observed biological effects are discussed in the context of these mechanisms and their relevance to ultrasound safety is discussed.
Collapse
Affiliation(s)
- G ter Haar
- Joint Department of Physics, Institute of Cancer Research, Royal Marsden Hospital, Sutton, Surrey SM2 5PT, UK,
| |
Collapse
|
12
|
Safety and bio-effects of ultrasound contrast agents. Med Biol Eng Comput 2009; 47:893-900. [DOI: 10.1007/s11517-009-0507-3] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2009] [Accepted: 06/21/2009] [Indexed: 10/20/2022]
|
13
|
Wink MH, Wijkstra H, De La Rosette JJMCH, Grimbergen CA. Ultrasound imaging and contrast agents: A safe alternative to MRI? MINIM INVASIV THER 2009; 15:93-100. [PMID: 16754192 DOI: 10.1080/13645700600674252] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Microbubble contrast media are used to enhance ultrasound images. Because ultrasound is a real-time investigation, contrast-enhanced ultrasound offers possibilities for perfusion imaging. This review is conducted to evaluate the safety of contrast-enhanced ultrasound and its possible role in medical imaging. The safety of diagnostic ultrasound is still an important field of research. The wanted and unwanted effects of ultrasound and microbubble contrast media as well as the effects of ultrasound on these microbubbles are described. Furthermore, some of the possible applications and indications of contrast-enhanced ultrasound will be discussed. The shared advantages of MRI and ultrasound are the use of non-ionizing radiation and non-nephrotoxic contrast media. From this review it can be concluded that, for certain indications, contrast enhanced ultrasound could be a safe alternative to MRI and a valuable addition to medical imaging.
Collapse
Affiliation(s)
- Margot H Wink
- Department of Urology, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.
| | | | | | | |
Collapse
|
14
|
Qin S, Caskey CF, Ferrara KW. Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering. Phys Med Biol 2009; 54:R27-57. [PMID: 19229096 PMCID: PMC2818980 DOI: 10.1088/0031-9155/54/6/r01] [Citation(s) in RCA: 280] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Microbubble contrast agents and the associated imaging systems have developed over the past 25 years, originating with manually-agitated fluids introduced for intra-coronary injection. Over this period, stabilizing shells and low diffusivity gas materials have been incorporated in microbubbles, extending stability in vitro and in vivo. Simultaneously, the interaction of these small gas bubbles with ultrasonic waves has been extensively studied, resulting in models for oscillation and increasingly sophisticated imaging strategies. Early studies recognized that echoes from microbubbles contained frequencies that are multiples of the microbubble resonance frequency. Although individual microbubble contrast agents cannot be resolved-given that their diameter is on the order of microns-nonlinear echoes from these agents are used to map regions of perfused tissue and to estimate the local microvascular flow rate. Such strategies overcome a fundamental limitation of previous ultrasound blood flow strategies; the previous Doppler-based strategies are insensitive to capillary flow. Further, the insonation of resonant bubbles results in interesting physical phenomena that have been widely studied for use in drug and gene delivery. Ultrasound pressure can enhance gas diffusion, rapidly fragment the agent into a set of smaller bubbles or displace the microbubble to a blood vessel wall. Insonation of a microbubble can also produce liquid jets and local shear stress that alter biological membranes and facilitate transport. In this review, we focus on the physical aspects of these agents, exploring microbubble imaging modes, models for microbubble oscillation and the interaction of the microbubble with the endothelium.
Collapse
Affiliation(s)
- Shengping Qin
- Department of Biomedical Engineering, University of California, 451 East Health Sciences Drive, Davis, CA 95616, USA
| | | | | |
Collapse
|
15
|
Miller DL, Averkiou MA, Brayman AA, Everbach EC, Holland CK, Wible JH, Wu J. Bioeffects considerations for diagnostic ultrasound contrast agents. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2008; 27:611-32; quiz 633-6. [PMID: 18359911 DOI: 10.7863/jum.2008.27.4.611] [Citation(s) in RCA: 166] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Diagnostic ultrasound contrast agents have been developed for enhancing the echogenicity of blood and for delineating other structures of the body. Approved agents are suspensions of gas bodies (stabilized microbubbles), which have been designed for persistence in the circulation and strong echo return for imaging. The interaction of ultrasound pulses with these gas bodies is a form of acoustic cavitation, and they also may act as inertial cavitation nuclei. This interaction produces mechanical perturbation and a potential for bioeffects on nearby cells or tissues. In vitro, sonoporation and cell death occur at mechanical index (MI) values less than the inertial cavitation threshold. In vivo, bioeffects reported for MI values greater than 0.4 include microvascular leakage, petechiae, cardiomyocyte death, inflammatory cell infiltration, and premature ventricular contractions and are accompanied by gas body destruction within the capillary bed. Bioeffects for MIs of 1.9 or less have been reported in skeletal muscle, fat, myocardium, kidney, liver, and intestine. Therapeutic applications that rely on these bioeffects include targeted drug delivery to the interstitium and DNA transfer into cells for gene therapy. Bioeffects of contrast-aided diagnostic ultrasound happen on a microscopic scale, and their importance in the clinical setting remains uncertain.
Collapse
Affiliation(s)
- Douglas L Miller
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109-0553, USA.
| | | | | | | | | | | | | |
Collapse
|
16
|
Stratmeyer ME, Greenleaf JF, Dalecki D, Salvesen KA. Fetal ultrasound: mechanical effects. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2008; 27:597-609. [PMID: 18359910 DOI: 10.7863/jum.2008.27.4.597] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
In this discussion, any biological effect of ultrasound that is accompanied by temperature increments less than 1 degrees C above normal physiologic levels is called a mechanical effect. However, one should keep in mind that the term mechanical effect also includes processes that are not of a mechanical nature but arise secondary to mechanical interaction between ultrasound and tissues, such as chemical reactions initiated by free oxygen species generated during cavitation and sonoluminescence. Investigations with laboratory animals have documented that pulsed ultrasound can produce damage to biological tissues in vivo through nonthermal mechanisms. The acoustic output used to induce these adverse bio-effects is considerably greater than the output of diagnostic devices when gas bodies are not present. However, low-intensity pulsed ultrasound is used clinically to accelerate the bone fracture repair process and induce healing of nonunions in humans. Low-intensity pulsed ultrasound also has been shown to enhance repair of soft tissue damage and accelerate nerve regeneration in animal models. Although such exposures to low intensity do not appear to cause damage to exposed tissues, they do raise questions about the acoustic threshold that might induce potentially adverse developmental effects in the fetus. To date, bioeffects studies in humans do not substantiate a causal relationship between diagnostic ultrasound exposure during pregnancy and adverse biological effects to the fetus. However, the epidemiologic studies were conducted with commercially available devices predating 1992, having outputs not exceeding a derated spatial-peak temporal-average intensity (ISPTA.3) of 94 mW/cm2. Current limits in the United States allow an ISPTA.3 of 720 mW/cm2 for obstetric modes. At the time of this report, available evidence, experimental or epidemiologic, is insufficient to conclude that there is a causal relationship between obstetric diagnostic ultrasound exposure and adverse nonthermal effects to the fetus. However, low-intensity pulsed ultrasound effects reported in humans and animal models indicate a need for further investigation of potentially adverse developmental effects.
Collapse
Affiliation(s)
- Melvin E Stratmeyer
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, 9200 Corporate Blvd, HFZ-120, Rockville, MD 20850 USA.
| | | | | | | |
Collapse
|
17
|
Rudzki JR, Adler RS, Warren RF, Kadrmas WR, Verma N, Pearle AD, Lyman S, Fealy S. Contrast-enhanced ultrasound characterization of the vascularity of the rotator cuff tendon: age- and activity-related changes in the intact asymptomatic rotator cuff. J Shoulder Elbow Surg 2008; 17:96S-100S. [PMID: 18069013 DOI: 10.1016/j.jse.2007.07.004] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2007] [Revised: 06/18/2007] [Accepted: 07/05/2007] [Indexed: 02/01/2023]
Abstract
The natural history of the blood supply to the rotator cuff and its role in the etiology of rotator cuff disease has not been definitively established. To date, there has not been an in-vivo dynamic assessment of the baseline vascularity of the asymptomatic rotator cuff. This study was designed to test the hypothesis that regional variations in supraspinatus tendon vascularity exist with an age-dependent decrease in asymptomatic individuals with intact rotator cuffs. Lipid microsphere, contrast-enhanced ultrasound shoulder examinations were done in 31 patients with a mean age of 41.5 years (range, 22-65 years). Images were obtained at baseline, after contrast administration at rest, and after contrast administration following exercise to visualize the intratendinous blood flow to the supraspinatus tendon. Qualitative and quantitative analysis was performed by determining 4 regions of interest (bursal medial, articular medial, bursal lateral, and articular lateral) with quantification and analysis software (QLAB Philips, Andover, MA) to examine each region of interest and normalize data for interpretation of the mean intensity per pixel. A statistically significant decrease in blood flow to the supraspinatus tendon with age was observed in a comparative analysis of patients aged younger than 40 and older than 40, (P < .05 for all 4 zones after exercise and for the bursal medial, articular medial, and bursal lateral zones after exercise; P = .07 for the articular lateral zone after exercise). A statistically significant increase in blood flow with exercise was observed in an analysis of all patients (P < .001). The age-related decrease in the vascular supply of the tendon observed in this study is consistent with published reports demonstrating an increasing prevalence of rotator cuff pathology with age and may predispose to the development of rotator cuff tendinopathy and, ultimately, attritional tears.
Collapse
Affiliation(s)
- Jonas R Rudzki
- Sports Medicine & Shoulder Service, Hospital for Special Surgery, New York, NY, USA.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Hirokawa T, Karshafian R, Pavlin CJ, Burns PN. Insonation of the eye in the presence of microbubbles: preliminary study of the duration and degree of vascular bioeffects--work in progress. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2007; 26:731-8. [PMID: 17526604 DOI: 10.7863/jum.2007.26.6.731] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
OBJECTIVE The purpose of this study was to investigate the presence and duration of vascular permeability changes induced by the combination of ultrasound and an intravascular microbubble contrast agent in the rabbit eye. METHODS Five eyes were studied in 8 anaesthetized rabbits. Insonation was performed with a diagnostic B-mode system (center frequency = 2 MHz; mechanical index [MI] = 0.2 and 1.7) for 5 minutes after administration of perflutren microbubbles (0.07 mL/kg). Fluorescein fundus angiography was performed before and 3 minutes after insonation; at 6 minutes, color fundus photography was used to assess the dye leakage, bleeding, and alteration of the diameter of fundus vessels. RESULTS Alteration of fundus vessel diameters was observed in 1 of 5 cases at a low MI and in 4 of 5 cases at a higher MI. In 1 case, leakage of fluorescein indicated increased permeability at the higher MI. No bleeding was detected in any case. CONCLUSIONS The permeability change induced by insonation and this dose of an ultrasound contrast agent appears to be transient under the conditions studied, although the time delay between insonation and optical assessment limits the completeness of the findings. This preliminary study may be relevant to drug delivery strategies using ultrasound and microbubbles.
Collapse
Affiliation(s)
- Tomihiko Hirokawa
- Department of Medical Biophysics, University of Toronto, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | | | | | | |
Collapse
|
19
|
Greenbaum L, Burns P, Copel J, Cosgrove D, Fowlkes JB, Goldberg B, Mattrey R, Merton D, Robbin M, Wilson S. American Institute ofUltrasound in Medicine recommendations for contrast-enhanced liver ultrasound imaging clinical trials. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2007; 26:705-16. [PMID: 17526602 DOI: 10.7863/jum.2007.26.6.705] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
|
20
|
Dalecki D. WFUMB Safety Symposium on Echo-Contrast Agents: bioeffects of ultrasound contrast agents in vivo. ULTRASOUND IN MEDICINE & BIOLOGY 2007; 33:205-13. [PMID: 17239521 DOI: 10.1016/j.ultrasmedbio.2006.07.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Affiliation(s)
- Diane Dalecki
- Department of Biomedical Engineering, Rochester Center for Biomedical Ultrasound, University of Rochester, Rochester, NY 14627, USA.
| |
Collapse
|
21
|
Abstract
Ultrasonic biophysics is the study of mechanisms responsible for how ultrasound and biological materials interact. Ultrasound-induced bioeffect or risk studies focus on issues related to the effects of ultrasound on biological materials. On the other hand, when biological materials affect the ultrasonic wave, this can be viewed as the basis for diagnostic ultrasound. Thus, an understanding of the interaction of ultrasound with tissue provides the scientific basis for image production and risk assessment. Relative to the bioeffect or risk studies, that is, the biophysical mechanisms by which ultrasound affects biological materials, ultrasound-induced bioeffects are generally separated into thermal and non-thermal mechanisms. Ultrasonic dosimetry is concerned with the quantitative determination of ultrasonic energy interaction with biological materials. Whenever ultrasonic energy is propagated into an attenuating material such as tissue, the amplitude of the wave decreases with distance. This attenuation is due to either absorption or scattering. Absorption is a mechanism that represents that portion of ultrasonic wave that is converted into heat, and scattering can be thought of as that portion of the wave, which changes direction. Because the medium can absorb energy to produce heat, a temperature rise may occur as long as the rate of heat production is greater than the rate of heat removal. Current interest with thermally mediated ultrasound-induced bioeffects has focused on the thermal isoeffect concept. The non-thermal mechanism that has received the most attention is acoustically generated cavitation wherein ultrasonic energy by cavitation bubbles is concentrated. Acoustic cavitation, in a broad sense, refers to ultrasonically induced bubble activity occurring in a biological material that contains pre-existing gaseous inclusions. Cavitation-related mechanisms include radiation force, microstreaming, shock waves, free radicals, microjets and strain. It is more challenging to deduce the causes of mechanical effects in tissues that do not contain gas bodies. These ultrasonic biophysics mechanisms will be discussed in the context of diagnostic ultrasound exposure risk concerns.
Collapse
Affiliation(s)
- William D O'Brien
- Bioacoustics Research Laboratory, Department of Electrical and Computer Engineering, University of Illinois, 405 N. Mathews, Urbana, IL 61801, USA.
| |
Collapse
|
22
|
Miller DL. Overview of experimental studies of biological effects of medical ultrasound caused by gas body activation and inertial cavitation. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2006; 93:314-30. [PMID: 16989895 DOI: 10.1016/j.pbiomolbio.2006.07.027] [Citation(s) in RCA: 104] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Ultrasound exposure can induce bioeffects in mammalian tissue by the nonthermal mechanism of gas body activation. Pre-existing bodies of gas may be activated even at low-pressure amplitudes. At higher-pressure amplitudes, violent cavitation activity with inertial collapse of microbubbles can be generated from latent nucleation sites or from the destabilization of gas bodies. Mechanical perturbation at the activation sites leads to biological effects on nearby cells and structures. Shockwave lithotripsy was the first medical ultrasound application for which significant cavitational bioeffects were demonstrated in mammalian tissues, including hemorrhage and injury in the kidney. Lithotripter shockwaves can also cause hemorrhage in lung and intestine by activation of pre-existing gas bodies in these tissues. Modern diagnostic ultrasound equipment develops pressure amplitudes sufficient for inertial cavitation, but the living body normally lacks suitable cavitation nuclei. Ultrasound contrast agents (UCAs) are suspensions of microscopic gas bodies created to enhance the echogenicity of blood. Ultrasound contrast agent gas bodies also provide nuclei for inertial cavitation. Bioeffects from contrast-aided diagnostic ultrasound depend on pressure amplitude, UCA dose, dosage delivery method and image timing parameters. Microvascular leakage, capillary rupture, cardiomyocyte killing, inflammatory cell infiltration, and premature ventricular contractions have been reported for myocardial contrast echocardiography with clinical ultrasound machines and clinically relevant agent doses in laboratory animals. Similar bioeffects have been reported in intestine, skeletal muscle, fat, lymph nodes and kidney. These microscale bioeffects could be induced unknowingly in diagnostic examinations; however, the medical significance of bioeffects of diagnostic ultrasound with contrast agents is not yet fully understood in relation to the clinical setting.
Collapse
Affiliation(s)
- Douglas L Miller
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|
23
|
Yoshioka T, Ageyama N, Shibata H, Yasu T, Misawa Y, Takeuchi K, Matsui K, Yamamoto K, Terao K, Shimada K, Ikeda U, Ozawa K, Hanazono Y. Repair of infarcted myocardium mediated by transplanted bone marrow-derived CD34+ stem cells in a nonhuman primate model. Stem Cells 2005; 23:355-64. [PMID: 15749930 DOI: 10.1634/stemcells.2004-0200] [Citation(s) in RCA: 93] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Rodent and human clinical studies have shown that transplantation of bone marrow stem cells to the ischemic myocardium results in improved cardiac function. In this study, cynomolgus monkey acute myocardial infarction was generated by ligating the left anterior descending artery, and autologous CD34(+) cells were transplanted to the peri-ischemic zone. To track the in vivo fate of transplanted cells, CD34(+) cells were genetically marked with green fluorescent protein (GFP) using a lentivirus vector before transplantation (marking efficiency, 41% on average). The group receiving cells (n = 4) demonstrated improved regional blood flow and cardiac function compared with the saline-treated group (n =4) at 2 weeks after transplant. However, very few transplanted cell-derived, GFP-positive cells were found incorporated into the vascular structure, and GFP-positive cardiomyocytes were not detected in the repaired tissue. On the other hand, cultured CD34(+) cells were found to secrete vascular endothelial growth factor (VEGF), and the in vivo regional VEGF levels showed a significant increase after the transplantation. These results suggest that the improvement is not the result of generation of transplanted cell-derived endothelial cells or cardiomyocytes; and raise the possibility that angiogenic cytokines secreted from transplanted cells potentiate angiogenic activity of endogenous cells.
Collapse
Affiliation(s)
- Toru Yoshioka
- Center for Molecular Medicine, Department of Internal Medicine, Jichi Medical School, Minamikawachi, Tochigi 329-0498, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Yasu T, Greener Y, Jablonski E, Killam AL, Fukuda S, Suematsu M, Tojo SJ, Schmid-Schönbein GW. Activated leukocytes and endothelial cells enhance retention of ultrasound contrast microspheres containing perfluoropropane in inflamed venules. Int J Cardiol 2005; 98:245-52. [PMID: 15686774 DOI: 10.1016/j.ijcard.2003.10.042] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2003] [Accepted: 10/12/2003] [Indexed: 11/21/2022]
Abstract
PURPOSE To characterize the flow dynamics of albumin ultrasound contrast microspheres containing perfluoropropane (PFP) in normal and inflamed microvasculature. MATERIALS AND METHODS Mesenteric microvessels of rats were examined after an intravenous injection of fluorocein-labeled erythrocytes or PFP microspheres by fluorescence intravital microscopy with and without local application of 10(-8) M platelet activating factor (PAF) as an experimental form of inflammation. RESULTS All the microspheres passed freely through arterioles and capillaries. Mean velocities of the microspheres in each vessel were closely correlated with those of erythrocytes. Only a minor fraction of the microspheres was retained in the venules (> or =0.1 s stoppage) by attachment to endothelial cells. The frequency of microsphere retention in venules was significantly enhanced by PAF (2.6+/-2.1%, P<0.01 vs. control), especially in regions with leukocyte adhesion. Treatment with a monoclonal antibody to intercellular adhesion molecule-1, P-selectin or the common leukocyte antigen inhibited PAF-induced microsphere retention in venules (P<0.05). In the inflamed microcirculation, a small subgroup of microspheres becomes attached to venular endothelial cells in regions with leukocyte adhesion via interaction among microspheres, activated leukocytes and endothelial cells via adhesion molecules. CONCLUSION In inflamed microcirculation, a small subgroup of microspheres becomes attached to venular endothelial cells in regions with leukocyte adhesion via interaction among microspheres, activated leukocytes and endothelial cells via adhesion molecules. These results suggest that ultrasonography with microspheres has the potential to evaluate inflammatory site distribution as well as tissue perfusion.
Collapse
Affiliation(s)
- Takanori Yasu
- Department of Bioengineering, University of California San Diego, La Jolla, CA 92093-0412, USA.
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Jakobsen JA, Oyen R, Thomsen HS, Morcos SK. Safety of ultrasound contrast agents. Eur Radiol 2005; 15:941-5. [PMID: 15662495 DOI: 10.1007/s00330-004-2601-0] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2004] [Accepted: 11/16/2004] [Indexed: 01/12/2023]
Abstract
The use of ultrasound contrast agents has increased over recent years. The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) decided to review the safety of ultrasound contrast agents in humans and to draw up guidelines. A comprehensive literature search and review was carried out. The resulting report was discussed by the CMSC of ESUR and at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain, in 2004. Ultrasound contrast agents approved for clinical use are well tolerated, and serious adverse reactions are rarely observed. Adverse events are usually minor (e.g. headache, nausea, altered taste, sensation of heat) and self-resolving. These symptoms may not be related to the ultrasound contrast materials as they have also been observed in placebo-control groups. Intolerance to some components may occur. Generalized allergy-like reactions occur rarely. Ultrasound contrast agents are generally safe. The ultrasound scanning time and the acoustic output should be kept to the lowest level consistent with obtaining diagnostic information. Adverse reactions should be treated symptomatically.
Collapse
Affiliation(s)
- Jarl A Jakobsen
- Department of Radiology, Rikshospitalet University Hospital, Oslo, Norway
| | | | | | | |
Collapse
|