Wang SH, Fuh LJ, Chen MYC, Tsai MT, Huang HL, Peng SL, Hsu JT. Preoperative assessment of bone density for dental implantation: a comparative study of three different ROI methods. Head Face Med 2024; 20:33. [PMID: 38760840 PMCID: PMC11100211 DOI: 10.1186/s13005-024-00434-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 05/10/2024] [Indexed: 05/19/2024] Open
Abstract
BACKGROUND Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.
Collapse
Affiliation(s)
- Shiuan-Hui Wang
- School of Dentistry, China Medical University, Taichung, 404, Taiwan
| | - Lih-Jyh Fuh
- School of Dentistry, China Medical University, Taichung, 404, Taiwan
- Department of Dentistry, China Medical University Hospital, Taichung, 404, Taiwan
| | - Michael Y C Chen
- School of Dentistry, China Medical University, Taichung, 404, Taiwan
- Department of Dentistry, China Medical University Hospital, Taichung, 404, Taiwan
| | - Ming-Tzu Tsai
- Department of Biomedical Engineering, Hungkuang University, Taichung, 433, Taiwan
| | - Heng-Li Huang
- Department of Dentistry, China Medical University Hospital, Taichung, 404, Taiwan
- Department of Biomedical Engineering, China Medical University, 91 Hsueh-Shih Road, Taichung, 40402, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung, 413, Taiwan
| | - Shin-Lei Peng
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung 91 Hsueh-Shih Road, Taichung, 40402, Taiwan.
| | - Jui-Ting Hsu
- Department of Dentistry, China Medical University Hospital, Taichung, 404, Taiwan.
- Department of Biomedical Engineering, China Medical University, 91 Hsueh-Shih Road, Taichung, 40402, Taiwan.
| |
Collapse
|
2
|
Pithani KD, Vadhi R. Enhanced non-alcoholic fatty liver detection: Computed tomography scan image analysis and noise reduction with morphological dilation. Arab J Gastroenterol 2024; 25:1-12. [PMID: 38245473 DOI: 10.1016/j.ajg.2023.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 07/26/2023] [Indexed: 01/22/2024]
Abstract
Non-alcoholic fatty liver disease (NAFLD) is characterized by accumulation of fat in the liver cells caused by means other than alcohol consumption. It is one of the most common chronic liver diseases worldwide and can lead to severe conditions, such as cirrhosis and liver cancer. NAFLD is often associated with other metabolic disorders, such as obesity and diabetes, and is closely related to lifestyle factors, such as diet and physical activity [1]. The diagnosis as well as management of NAFLD are complex and involve a multidisciplinary approach. The available treatment options include lifestyle modifications, pharmacological interventions, and in severe cases, liver transplantation. The increasing prevalence of NAFLD highlights the urgent requirement of effective prevention and management strategies. This disease is a growing health concern in India, given the rise in the incidence of obesity and diabetes. According to a study published in the Journal of Clinical and Experimental Hepatology in 2020, the prevalence of NAFLD in India is estimated to be between 9% and 32%. In accordance with the research population and diagnostic criteria employed, a study published in the Indian Journal of Gastroenterology in 2019 found that the prevalence of NAFLD in India ranged from 9.6% to 32.3% [2]. The same study also revealed that the prevalence of non-alcoholic steatohepatitis (NASH), a highly severe form of NAFLD, ranged from 1.5% to 8.4%. These statistics highlight the need for increased awareness and preventive measures to manage the growing burden of NAFLD in India.
Collapse
Affiliation(s)
- Kishan Dev Pithani
- Electronics and Communication Engineering, Pragati Engineering College, Surampalem, Kakinada 533437, Andhra Pradesh, India.
| | - Radhika Vadhi
- Electronics and Communication Engineering, Pragati Engineering College, Surampalem, Kakinada 533437, Andhra Pradesh, India.
| |
Collapse
|
3
|
Wen C, Zhang Q. Pilot study of fractal dimension analysis of osteogenesis for bone substitute materials of Bio-Oss in lateral sinus augmentation. PLoS One 2023; 18:e0296248. [PMID: 38157335 PMCID: PMC10756558 DOI: 10.1371/journal.pone.0296248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 12/09/2023] [Indexed: 01/03/2024] Open
Abstract
BACKGROUND Fractal dimension (FD) analysis has been proposed and validated in osseointegration-related research. The aim of this study was to evaluate the feasibility of FD analysis in the osteogenesis detection of bone substitute materials (BSMs) of Bio-Oss in maxillary lateral sinus augmentation. METHODS Patients who received lateral maxillary sinus augmentation and underwent grafting with BSMs (Bio-Oss) were included in the study. The cross sections of the BSMs under cone-beam computed tomography (CBCT) at mesial, distal, and sagittal directions were obtained immediately after the graft (T0) and 6 months later (T1), and the obtained images were cropped to include only the BSMs. The FD analysis was performed, and the FD value was obtained by the method of box-counting. Paired t-tests and analysis of variance (ANOVA) were used, and p-values <0.05 was considered statistically significant. RESULTS Twelve participants with 22 implants, which were inserted simultaneously after sinus augmentation, were included in this study. A total of 22 mesial, 22 distal, and 14 sagittal images were obtained after FD analysis. The mean FD value and standard deviation at T0 was 1.2860 ± 0.0896, while at T1, it was 1.2508±0.1023; thus, significant differences were detected (p = 0.022). However, the increasing or decreasing trend of FD value was not stable, and no significant difference was detected for FD values of mesial, distal, and sagittal images between T0 and T1. ANOVA indicated that no significant difference was detected among the FD values of mesial, distal, and sagittal images at any timepoint. Differences in FD values between the sexes were not significant either. CONCLUSIONS Since the FD analysis for the osteogenesis detection of BSMs in maxillary sinus augmentation indicated unstable trends of change, its feasibility is not reliable. The initially rough surface, self-degradation, and volume change of the BSMs during osteogenesis may be the reason for the variation in FD values.
Collapse
Affiliation(s)
- Cai Wen
- Department of Oral Implantology, The Affiliated Stomatology Hospital, Southwest Medical University, Luzhou, Sichuan, China
- Department of VIP Dental Service, The Affiliated Stomatology Hospital, Southwest Medical University, Luzhou, Sichuan, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatology Hospital, Southwest Medical University, Luzhou, Sichuan, China
- Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
| | - Qing Zhang
- Department of Nosocomial Infection Control, The Affiliated Hospital, Southwest Medical University, Luzhou, Sichuan, China
| |
Collapse
|
4
|
Khaohoen A, Sornsuwan T, Chaijareenont P, Poovarodom P, Rungsiyakull C, Rungsiyakull P. Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density-A Narrative Review. J Clin Med 2023; 12:6924. [PMID: 37959389 PMCID: PMC10649288 DOI: 10.3390/jcm12216924] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 10/29/2023] [Accepted: 11/02/2023] [Indexed: 11/15/2023] Open
Abstract
Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as its excellent balance of rigidity and stiffness. Since zirconia is a soft-tissue-friendly material and caters to esthetic demands, it is an alternative to titanium for use in implants. Nevertheless, bone density plays a vital role in determining the material and design of implants. Compromised bone density leads to both early and late implant failures due to a lack of implant stability. Therefore, this narrative review aims to investigate the influence of implant material/design and surgical technique on bone density from both biomechanical and biological standpoints. Relevant articles were included for analysis. Dental implant materials can be fabricated from titanium, zirconia, and PEEK. In terms of mechanical and biological aspects, titanium is still the gold standard for dental implant materials. Additionally, the macro- and microgeometry of dental implants play a role in determining and planning the appropriate treatment because it can enhance the mechanical stress transmitted to the bone tissue. Under low-density conditions, a conical titanium implant design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, and deep thread depth are recommended. Implant material, implant design, surgical techniques, and bone density are pivotal factors affecting the success rates of dental implant placement in low-density bone. Further study is required to find the optimal implant material for a clinical setting's bone state.
Collapse
Affiliation(s)
- Angkoon Khaohoen
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Tanapon Sornsuwan
- Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok 65000, Thailand;
| | - Pisaisit Chaijareenont
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Pongsakorn Poovarodom
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand;
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| |
Collapse
|
5
|
Yadegari A, Safi Y, Shahbazi S, Yaghoutiazar S, Ghazizadeh Ahsaie M. Assessment of CBCT gray value in different regions-of-interest and fields-of-view compared to Hounsfield unit. Dentomaxillofac Radiol 2023; 52:20230187. [PMID: 37874074 DOI: 10.1259/dmfr.20230187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023] Open
Abstract
OBJECTIVES Different factors can affect the discrepancy between the gray value (GV) measurements obtained from CBCT and the Hounsfield unit (HU) derived from multidetector CT (MDCT), which is considered the gold-standard density scale. This study aimed to explore the impact of region of interest (ROI) location and field of view (FOV) size on the difference between these two scales as a potential source of error. METHODS Three phantoms, each consisting of a water-filled plastic bin containing a dry dentate human skull, were prepared. CBCT scans were conducted using the NewTom VGi evo system, while MDCT scans were performed using Philips system. Three different FOV sizes (8 × 8 cm, 8 × 12 cm, and 12 × 15 cm) were used, and the GVs obtained from eight distinct ROIs were compared with the HUs from the MDCT scans. The ROIs included dental and bony regions within the anterior and posterior areas of both jaws. Statistical analyses were performed using SPSS v. 26. RESULTS The GVs derived from CBCT images were significantly influenced by both ROI location and FOV size (p < 0.05 for both factors). Following the comparison between GVs and HUs, the anterior mandibular bone ROI represented the minimum error, while the posterior mandibular teeth exhibited the maximum error. Moreover, the 8 × 8 cm and 12 × 15 cm FOVs resulted in the lowest and highest degrees of GV error, respectively. CONCLUSIONS The ROI location and the FOV size can significantly affect the GVs obtained from CBCT images. It is not recommended to use the GV scale within the posterior mandibular teeth region due to the potential for error. Additionally, selecting smaller FOV sizes, such as 8 × 8 cm, can provide GVs closer to the gold-standard numbers.
Collapse
Affiliation(s)
- Atiye Yadegari
- Department of Pediatric Dentistry, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Yaser Safi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Soheil Shahbazi
- Dental Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Sahar Yaghoutiazar
- Department of Pediatric Dentistry, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mitra Ghazizadeh Ahsaie
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Hasani M, Afzoon S, Karandish M, Parastar M. Three-dimensional evaluation of the cortical and cancellous bone density and thickness for miniscrew insertion: a CBCT study of interradicular area of adults with different facial growth pattern. BMC Oral Health 2023; 23:753. [PMID: 37833666 PMCID: PMC10571361 DOI: 10.1186/s12903-023-03440-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023] Open
Abstract
AIM The purpose of this study was to evaluate the effect of the density and the thickness of the cortical and the cancellous bone at selected inter-radicular areas in subjects with different facial growth patterns using cone beam computed tomography (CBCT) in order to choose the optimal area for miniscrew insertion. MATERIALS AND METHODS From 150 CBCT scans, 45 scans were included in the study. The subjects were categorized into three groups based on their skeletal growth pattern according to SN-GoMe angle and facial height index. Cortical and cancellous bone density and thickness were measured at the selected inter-radicular areas. RESULTS Compared to the other two groups, the hyperdivergent group had thinner cortical bone in the anterior region of the maxilla between the central and the lateral incisors on the buccal side at 4 mm from the alveolar crest (P-value: 0.012) and on the palatal side at 7 mm from the alveolar crest (P-value: 0.030). Cancellous bone density values in these areas were higher in subjects with hypodivergent and hyperdivergent growth pattern. Furthermore, in hyperdivergent group less dense cortical bone in the posterior region of the maxilla on the palatal side between the second premolar and the first molar (p-value: 0.020) and on the buccal side between the first molar and the second molar (p-value: 0.038 & 0.047) was observed. No significant differences were found in the mandible between the three groups. No significant differences were found between the male and the female subjects. CONCLUSION Hyperdivegents presented thinner cortical bone in the anterior of the maxilla between the central and the lateral incisors. Less dense cortical bone was found between maxillary second premolar and first molar on the palatal side and also between the maxillary first molar and the second molar on the buccal side in this group too. Normal showed higher density values in the posterior of the maxilla compared to the other two groups. No significant differences were found among three groups in mandible.
Collapse
Affiliation(s)
- Mahvash Hasani
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Afzoon
- School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Maryam Karandish
- Department of Orthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Mina Parastar
- School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
7
|
Lee SH, Yun PY, Yi YJ, Kim YK, Lee HJ, Jo DW. Low Bone Density Predictability of CBCT and Its Relation to Primary Stability of Tapered Implant Design: A Pilot Study. J ORAL IMPLANTOL 2023; 49:556-563. [PMID: 35881816 DOI: 10.1563/aaid-joi-d-21-00159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 04/04/2022] [Accepted: 05/31/2022] [Indexed: 11/22/2022]
Abstract
Research regarding bone density assessment using cone beam computed tomography (CBCT) in low bone density regions is sparse. This in vitro study aimed to evaluate the predictability of CBCT for low bone density regions and its correlations with primary implant stability when placing tapered design implants with a stepped osteotomy. Eighteen porcine mandibular condyles were used as simulated low bone density regions. Hounsfield units (HU), obtained via multislice computed tomography, and gray values (GVs), obtained via CBCT, were measured 3 times at 1-month intervals. The maximum implant insertion torque (MIT) and implant stability quotient (ISQ) were recorded as the taper design implants were placed using a stepped osteotomy. Hounsfield units and GV were measured as 335.05-803.07 and 389.98-906.40, respectively. For repeated measurements of HU and GV, the intraclass correlation coefficients were 0.989 and 0.980; the corresponding value for mean HU and GV was 0.768. Bland-Altman plots showed a mean difference between HU and GV of -78.15. Pearson correlation coefficients revealed a strong correlation between HU and GV (r = 0.91, P < .01). The mean ± SD values for MIT and ISQ were 36.44 ± 6.64 Ncm and 80.85 ± 2.03, respectively, but no statistically significant correlations were found with GV and HU. Within the study's limitations, GV showed similar bone density estimation compared with HU in soft bones. Tapered implant placement with a stepped osteotomy achieved stable primary implant stability in soft bones. However, these in vitro results need to be approved in further clinical studies.
Collapse
Affiliation(s)
- Sang-Hoon Lee
- Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Pil-Young Yun
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
- Department of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Yang-Jin Yi
- Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
- Department of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Young-Kyun Kim
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Hyo-Jung Lee
- Department of Periodontology, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Deuk-Won Jo
- Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| |
Collapse
|
8
|
Wagendorf O, Nahles S, Vach K, Kernen F, Zachow S, Heiland M, Flügge T. The impact of teeth and dental restorations on gray value distribution in cone-beam computer tomography: a pilot study. Int J Implant Dent 2023; 9:27. [PMID: 37676412 PMCID: PMC10484826 DOI: 10.1186/s40729-023-00493-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 08/29/2023] [Indexed: 09/08/2023] Open
Abstract
PURPOSE To investigate the influence of teeth and dental restorations on the facial skeleton's gray value distributions in cone-beam computed tomography (CBCT). METHODS Gray value selection for the upper and lower jaw segmentation was performed in 40 patients. In total, CBCT data of 20 maxillae and 20 mandibles, ten partial edentulous and ten fully edentulous in each jaw, respectively, were evaluated using two different gray value selection procedures: manual lower threshold selection and automated lower threshold selection. Two sample t tests, linear regression models, linear mixed models, and Pearson's correlation coefficients were computed to evaluate the influence of teeth, dental restorations, and threshold selection procedures on gray value distributions. RESULTS Manual threshold selection resulted in significantly different gray values in the fully and partially edentulous mandible. (p = 0.015, difference 123). In automated threshold selection, only tendencies to different gray values in fully edentulous compared to partially edentulous jaws were observed (difference: 58-75). Significantly different gray values were evaluated for threshold selection approaches, independent of the dental situation of the analyzed jaw. No significant correlation between the number of teeth and gray values was assessed, but a trend towards higher gray values in patients with more teeth was noted. CONCLUSIONS Standard gray values derived from CT imaging do not apply for threshold-based bone segmentation in CBCT. Teeth influence gray values and segmentation results. Inaccurate bone segmentation may result in ill-fitting surgical guides produced on CBCT data and misinterpreting bone density, which is crucial for selecting surgical protocols. Created with BioRender.com.
Collapse
Affiliation(s)
- Oliver Wagendorf
- Department of Oral and Maxillofacial Surgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Susanne Nahles
- Department of Oral and Maxillofacial Surgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Kirstin Vach
- Faculty of Medicine and Medical Center, Institute of Medical Biometry and Statistics, University of Freiburg, Stefan-Meier-Straße 26, 79104, Freiburg im Breisgau, Germany
| | - Florian Kernen
- Department of Oral and Maxillofacial Surgery and Translational Implantology, Faculty of Medicine and Medical Center, University of Freiburg, Stefan-Meier-Straße 26, 79104, Freiburg im Breisgau, Germany
| | - Stefan Zachow
- Department of Oral and Maxillofacial Surgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
- Zuse Institute Berlin (ZIB), Takustraße 7, 14195, Berlin, Germany
| | - Max Heiland
- Department of Oral and Maxillofacial Surgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Tabea Flügge
- Department of Oral and Maxillofacial Surgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
9
|
Solnik M, Paduszyńska N, Czarnecka AM, Synoradzki KJ, Yousef YA, Chorągiewicz T, Rejdak R, Toro MD, Zweifel S, Dyndor K, Fiedorowicz M. Imaging of Uveal Melanoma—Current Standard and Methods in Development. Cancers (Basel) 2022; 14:cancers14133147. [PMID: 35804919 PMCID: PMC9265106 DOI: 10.3390/cancers14133147] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 06/06/2022] [Accepted: 06/13/2022] [Indexed: 11/19/2022] Open
Abstract
Simple Summary Uveal melanoma is the most prevalent intraocular tumor in adults, derived from melanocytes; the liver is the most common site of its metastases. Due to troublesome tumor localization, different imaging techniques are utilized in diagnostics, i.e., fundus imaging (FI), ultrasonography (US), optical coherence tomography (OCT), single-photon emission computed tomography (SPECT), positron emission tomography/computed tomography (PET/CT), magnetic resonance imaging (MRI), fundus fluorescein angiography (FFA), indocyanine green angiography (ICGA), or fundus autofluorescence (FAF). Specialists eagerly use these techniques, but sometimes the precision and quality of the obtained images are imperfect, raising diagnostic doubts and prompting the search for new ones. In addition to analyzing the currently utilized methods, this review also introduces experimental techniques that may be adapted to clinical practice in the future. Moreover, we raise the topic and present a perspective for personalized medicine in uveal melanoma treatment. Abstract Uveal melanoma is the most common primary intraocular malignancy in adults, characterized by an insidious onset and poor prognosis strongly associated with tumor size and the presence of distant metastases, most commonly in the liver. Contrary to most tumor identification, a biopsy followed by a pathological exam is used only in certain cases. Therefore, an early and noninvasive diagnosis is essential to enhance patients’ chances for early treatment. We reviewed imaging modalities currently used in the diagnostics of uveal melanoma, including fundus imaging, ultrasonography (US), optical coherence tomography (OCT), single-photon emission computed tomography (SPECT), fundus fluorescein angiography (FFA), indocyanine green angiography (ICGA), fundus autofluorescence (FAF), as well as positron emission tomography/computed tomography (PET/CT) or magnetic resonance imaging (MRI). The principle of imaging techniques is briefly explained, along with their role in the diagnostic process and a summary of their advantages and limitations. Further, the experimental data and the advancements in imaging modalities are explained. We describe UM imaging innovations, show their current usage and development, and explain the possibilities of utilizing such modalities to diagnose uveal melanoma in the future.
Collapse
Affiliation(s)
- Małgorzata Solnik
- Faculty of Medicine, Medical University of Warsaw, 02-091 Warsaw, Poland; (M.S.); (N.P.)
- Department of Soft Tissue/Bone Sarcoma and Melanoma, Maria Sklodowska-Curie National Research Institute of Oncology, 5 Roentgen Str., 02-781 Warsaw, Poland;
| | - Natalia Paduszyńska
- Faculty of Medicine, Medical University of Warsaw, 02-091 Warsaw, Poland; (M.S.); (N.P.)
- Department of Soft Tissue/Bone Sarcoma and Melanoma, Maria Sklodowska-Curie National Research Institute of Oncology, 5 Roentgen Str., 02-781 Warsaw, Poland;
| | - Anna M. Czarnecka
- Department of Soft Tissue/Bone Sarcoma and Melanoma, Maria Sklodowska-Curie National Research Institute of Oncology, 5 Roentgen Str., 02-781 Warsaw, Poland;
- Department of Experimental Pharmacology, Mossakowski Medical Research Institute, Polish Academy of Sciences, 5 Pawinskiego Str., 02-106 Warsaw, Poland
| | - Kamil J. Synoradzki
- Department of Experimental Pharmacology, Mossakowski Medical Research Institute, Polish Academy of Sciences, 5 Pawinskiego Str., 02-106 Warsaw, Poland
- Small Animal Magnetic Resonance Imaging Laboratory, Mossakowski Medical Research Institute, Polish Academy of Sciences, 5 Pawinskiego Str., 02-106 Warsaw, Poland;
- Correspondence:
| | - Yacoub A. Yousef
- Department of Surgery (Ophthalmology), King Hussein Cancer Centre, Amman 11941, Jordan;
| | - Tomasz Chorągiewicz
- Department of General and Pediatric Ophthalmology, Medical University of Lublin, Chmielna 1, 20-079 Lublin, Poland; (T.C.); (R.R.); (M.D.T.)
| | - Robert Rejdak
- Department of General and Pediatric Ophthalmology, Medical University of Lublin, Chmielna 1, 20-079 Lublin, Poland; (T.C.); (R.R.); (M.D.T.)
| | - Mario Damiano Toro
- Department of General and Pediatric Ophthalmology, Medical University of Lublin, Chmielna 1, 20-079 Lublin, Poland; (T.C.); (R.R.); (M.D.T.)
- Eye Clinic, Public Health Department, Federico II University, via Pansini 5, 80131 Naples, Italy
| | - Sandrine Zweifel
- Department of Ophthalmology, University of Zurich, 8091 Zurich, Switzerland;
| | - Katarzyna Dyndor
- Department of Radiography, Medical University of Lublin, 8 Jaczewskiego Str., 20-090 Lublin, Poland;
| | - Michał Fiedorowicz
- Small Animal Magnetic Resonance Imaging Laboratory, Mossakowski Medical Research Institute, Polish Academy of Sciences, 5 Pawinskiego Str., 02-106 Warsaw, Poland;
| |
Collapse
|
10
|
Supachaiyakit P, Serichetaphongse P, Chengprapakorn W. The influence of implant design on implant stability in low-density bone under guided surgical template in inexperienced surgeons: A pilot randomized controlled clinical trial using resonance frequency analysis. Clin Implant Dent Relat Res 2022; 24:444-454. [PMID: 35580961 DOI: 10.1111/cid.13100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 03/21/2022] [Accepted: 05/01/2022] [Indexed: 11/28/2022]
Abstract
INTRODUCTION There are several factors that greatly influence implant stability with implant design being a paramount factor; however, few studies investigate its impact. AIM To investigate the implant stability in relation to two different implant designs, a cylindrical shaped single-threaded design (CS/ST) and a tapered shaped double-threaded design (TS/DT) using resonance frequency analysis over the first 8 weeks after implantation. MATERIALS AND METHODS Twenty-eight implants were randomly allocated using computer-generated random numbers into two groups and were placed as single tooth implant in the posterior arch in human jaw as specimens. iCAT™ CBCT scan (Hatfield, PA) was used to determine the bone density according to Misch's Bone classification. The osseotomy sites were prepared and implants were placed with guided surgical template by inexperienced surgeons which were prepared with the same implant planning software (3shape® implant studio). The implant stability was measured using the resonance frequency analysis Osstell® ISQ (Osstell AB, Sweden) on the implant level over the first 8 weeks at three different time intervals. A mean implant stability quotient (ISQ) value was recorded at each measurement time points. The first ISQ of each implant recorded at the time of implant placement were considered as baseline and were the so-called primary stability. RESULTS All 28 dental implants were analyzed. A similar pattern of implant stability changes was observed in both implant designs. A significant decreased was found at the first 4 weeks after implantation (p < 0.05) before ascending to maximum cumulative stability by the eighth week (p < 0.05). Between the two groups, TS/DT group had a higher mean ISQ values than that of the CS/ST group at all three observation periods but did not reach statistical significance (p = 0.69). Regarding different types of bone, TS/DT showed a significant difference in mean ISQ values in D4 bone. To date, all 28 implants are in function with no failure/and or complications. CONCLUSIONS The difference in implant design did not significantly influence the implant stability. TS/DT shows superiority over CS/ST when placed in D4 bone and offer a significant advantage due to their positive bounce back of the ISQ values by the eighth week after implant installation. CLINICAL TRIAL REGISTRATION TCTR20211020005.
Collapse
Affiliation(s)
- Pinmuk Supachaiyakit
- Esthetic Restorative and Implant Dentistry Program, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Pravej Serichetaphongse
- Esthetic Restorative and Implant Dentistry Program, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | | |
Collapse
|
11
|
The Assessment of the Usefulness of Platelet-Rich Fibrin in the Healing Process Bone Resorption. COATINGS 2022. [DOI: 10.3390/coatings12020247] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
The main subject of this research was the use of PRF in dental surgery aimed at preventing changes in alveolar height and width after tooth extraction. Due to the large growth factor content, it seems to be particularly useful in bone loss management starting from the simplest loss occurring after tooth extraction through loss resulting from tooth resection ending with loss caused by large bone cysts. The study was performed on 50 patients. The extraction of two maxillary or mandibular homonymous teeth was carried out in each patient, where PRF was placed in one alveolus while the other alveolus was left empty. Then, the alveoli were surgically managed with a split flap technique. On the extraction day, after 10 days, and after 6 months, the alveolar process was measured, soft tissues healing was assessed, and imaging examinations were analyzed. It was proved that the healing of soft tissues in the PRF group was better. In the PRF group after 6 months from surgery, the newly formed bone had higher grayscale values in volumetric tomography (CBCT). Moreover, the reduced atrophy of the alveolar process at the site of the extracted tooth was proved in this study.
Collapse
|
12
|
Selvaraj A, Jain RK, Nagi R, Balasubramaniam A. Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis. Imaging Sci Dent 2022; 52:133-140. [PMID: 35799965 PMCID: PMC9226229 DOI: 10.5624/isd.20210274] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 02/28/2022] [Accepted: 03/18/2022] [Indexed: 11/22/2022] Open
Abstract
Purpose The aim of this review was to systematically analyze the available literature on the correlation between the gray values (GVs) of cone-beam computed tomography (CBCT) and the Hounsfield units (HUs) of computed tomography (CT) for assessing bone mineral density. Materials and Methods A literature search was carried out in PubMed, Cochrane Library, Google Scholar, Scopus, and LILACS for studies published through September 2021. In vitro, in vivo, and animal studies that analyzed the correlations GVs of CBCT and HUs of CT were included in this review. The review was prepared according to the PRISMA checklist for systematic reviews, and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A quantitative analysis was performed using a fixed-effects model. Results The literature search identified a total of 5,955 studies, of which 14 studies were included for the qualitative analysis and 2 studies for the quantitative analysis. A positive correlation was observed between the GVs of CBCT and HUs of CT. Out of the 14 studies, 100% had low risks of bias for the domains of patient selection, index test, and reference standards, while 95% of studies had a low risk of bias for the domain of flow and timing. The fixed-effects meta-analysis performed for Pearson correlation coefficients between CBCT and CT showed a moderate positive correlation (r=0.669; 95% CI, 0.388 to 0.836; P<0.05). Conclusion The available evidence showed a positive correlation between the GVs of CBCT and HUs of CT.
Collapse
Affiliation(s)
- Abirami Selvaraj
- Department of Orthodontics and Dentofacial Orthopaedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
| | - Ravindra Kumar Jain
- Department of Orthodontics and Dentofacial Orthopaedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
| | - Ravleen Nagi
- Department of Oral Medicine and Radiology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
| | - Arthi Balasubramaniam
- Department of Public Health Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
| |
Collapse
|