1
|
Ioussoufovitch S, Cohen DJF, Milej D, Diop M. Compressed sensing time-resolved spectrometer for quantification of light absorbers in turbid media. BIOMEDICAL OPTICS EXPRESS 2021; 12:6442-6460. [PMID: 34745748 PMCID: PMC8547999 DOI: 10.1364/boe.433427] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 08/20/2021] [Accepted: 09/10/2021] [Indexed: 06/13/2023]
Abstract
Time-resolved (TR) spectroscopy is well-suited to address the challenges of quantifying light absorbers in highly scattering media such as living tissue; however, current TR spectrometers are either based on expensive array detectors or rely on wavelength scanning. Here, we introduce a TR spectrometer architecture based on compressed sensing (CS) and time-correlated single-photon counting. Using both CS and basis scanning, we demonstrate that-in homogeneous and two-layer tissue-mimicking phantoms made of Intralipid and Indocyanine Green-the CS method agrees with or outperforms uncompressed approaches. Further, we illustrate the superior depth sensitivity of TR spectroscopy and highlight the potential of the device to quantify absorption changes in deeper (>1 cm) tissue layers.
Collapse
Affiliation(s)
- Seva Ioussoufovitch
- Western University, Faculty of Engineering, School of Biomedical Engineering, Collaborative Training Program in Musculoskeletal Health Research, Bone & Joint Institute, 1151 Richmond St., London, N6A 5C1, Canada
| | - David Jonathan Fulop Cohen
- Western University, Schulich School of Medicine & Dentistry, Department of Medical Biophysics, 1151 Richmond St., London, N6A 5C1, Canada
| | - Daniel Milej
- Western University, Schulich School of Medicine & Dentistry, Department of Medical Biophysics, 1151 Richmond St., London, N6A 5C1, Canada
- Lawson Health Research Institute, Imaging Program, 268 Grosvenor St., London, N6A 4V2, Canada
| | - Mamadou Diop
- Western University, Faculty of Engineering, School of Biomedical Engineering, Collaborative Training Program in Musculoskeletal Health Research, Bone & Joint Institute, 1151 Richmond St., London, N6A 5C1, Canada
- Western University, Schulich School of Medicine & Dentistry, Department of Medical Biophysics, 1151 Richmond St., London, N6A 5C1, Canada
- Lawson Health Research Institute, Imaging Program, 268 Grosvenor St., London, N6A 4V2, Canada
| |
Collapse
|
2
|
The Use of Supercontinuum Laser Sources in Biomedical Diffuse Optics: Unlocking the Power of Multispectral Imaging. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11104616] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Optical techniques based on diffuse optics have been around for decades now and are making their way into the day-to-day medical applications. Even though the physics foundations of these techniques have been known for many years, practical implementation of these technique were hindered by technological limitations, mainly from the light sources and/or detection electronics. In the past 20 years, the developments of supercontinuum laser (SCL) enabled to unlock some of these limitations, enabling the development of system and methodologies relevant for medical use, notably in terms of spectral monitoring. In this review, we focus on the use of SCL in biomedical diffuse optics, from instrumentation and methods developments to their use for medical applications. A total of 95 publications were identified, from 1993 to 2021. We discuss the advantages of the SCL to cover a large spectral bandwidth with a high spectral power and fast switching against the disadvantages of cost, bulkiness, and long warm up times. Finally, we summarize the utility of using such light sources in the development and application of diffuse optics in biomedical sciences and clinical applications.
Collapse
|
3
|
Broadband Time Domain Diffuse Optical Reflectance Spectroscopy: A Review of Systems, Methods, and Applications. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9245465] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This review presents recent developments and a wide overview of broadband time domain diffuse optical spectroscopy (TD-DOS). Various topics including physics of photon migration, advanced instrumentation, methods of analysis, applications covering multiple domains (tissue chromophore, in vivo studies, food, wood, pharmaceutical industry) are elaborated. The key role of standardization and recent studies in that direction are discussed. Towards the end, a brief outlook is presented on the current status and future trends in broadband TD-DOS.
Collapse
|
4
|
Kitsmiller VJ, Dummer MM, Johnson K, Cole GD, O'Sullivan TD. Frequency domain diffuse optical spectroscopy with a near-infrared tunable vertical cavity surface emitting laser. OPTICS EXPRESS 2018; 26:21033-21043. [PMID: 30119409 DOI: 10.1364/oe.26.021033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
We present an approach for performing frequency domain diffuse optical spectroscopy (fd-DOS) utilizing a near-infrared tunable vertical cavity surface emitting laser (VCSEL) that enables high spectral resolution optical sensing in a miniature format. The tunable VCSEL, designed specifically for deep tissue imaging and sensing, utilizes an electrothermally tunable microelectromechanical systems topside mirror to tune the laser cavity resonance. At room temperature, the laser is tunable across 14nm from 769 to 782nm with single mode CW output and a peak output power of 1.3mW. We show that the tunable VCSEL is suitable for use in fd-DOS by measuring the optical properties of a tissue-simulating phantom over the tunable range. Optical properties were recovered within 0.0006mm-1 (absorption) and 0.09mm-1 (reduced scattering) compared to a broadband fd-DOS reference system. Our results indicate that tunable VCSELs may be an attractive choice to enable high spectral resolution optical sensing in a wearable format.
Collapse
|
5
|
Gerega A, Milej D, Weigl W, Kacprzak M, Liebert A. Multiwavelength time-resolved near-infrared spectroscopy of the adult head: assessment of intracerebral and extracerebral absorption changes. BIOMEDICAL OPTICS EXPRESS 2018; 9:2974-2993. [PMID: 29984079 PMCID: PMC6033559 DOI: 10.1364/boe.9.002974] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Revised: 04/27/2018] [Accepted: 05/17/2018] [Indexed: 05/23/2023]
Abstract
An optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for the clinical assessment of brain perfusion at the bedside. We report on multiwavelength time-resolved diffuse reflectance spectroscopy measurements carried out on the head of a healthy adult during the intravenous administration of a bolus of ICG. Intracerebral and extracerebral changes in absorption were estimated from an analysis of changes in statistical moments (total number of photons, mean time of flight and variance) of the distributions of times of flight (DTOF) of photons recorded simultaneously at 16 wavelengths from the range of 650-850 nm using sensitivity factors estimated by diffusion approximation based on a layered model of the studied medium. We validated the proposed method in a series of phantom experiments and in-vivo measurements. The results obtained show that changes in the concentration of the ICG can be assessed as a function of time of the experiment and depth in the tissue. Thus, the separation of changes in ICG concentration appearing in intra- and extracerebral tissues can be estimated from optical data acquired at a single source-detector pair of fibers/fiber bundles positioned on the surface of the head.
Collapse
Affiliation(s)
- Anna Gerega
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences Trojdena 4, 02-109 Warsaw, Poland
| | - Daniel Milej
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences Trojdena 4, 02-109 Warsaw, Poland
- Department of Medical Biophysics, Western University, London, Ontario N6A 5C1, Canada
- Imaging Division, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada
| | - Wojciech Weigl
- Anesthesiology and Intensive Care, Department of Surgical Sciences, Uppsala University, Akademiska Hospital, 751 85 Uppsala, Sweden
| | - Michal Kacprzak
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences Trojdena 4, 02-109 Warsaw, Poland
| | - Adam Liebert
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences Trojdena 4, 02-109 Warsaw, Poland
| |
Collapse
|
6
|
Pifferi A, Contini D, Mora AD, Farina A, Spinelli L, Torricelli A. New frontiers in time-domain diffuse optics, a review. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:091310. [PMID: 27311627 DOI: 10.1117/1.jbo.21.9.091310] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2016] [Accepted: 05/24/2016] [Indexed: 05/20/2023]
Abstract
The recent developments in time-domain diffuse optics that rely on physical concepts (e.g., time-gating and null distance) and advanced photonic components (e.g., vertical cavity source-emitting laser as light sources, single photon avalanche diode, and silicon photomultipliers as detectors, fast-gating circuits, and time-to-digital converters for acquisition) are focused. This study shows how these tools could lead on one hand to compact and wearable time-domain devices for point-of-care diagnostics down to the consumer level and on the other hand to powerful systems with exceptional depth penetration and sensitivity.
Collapse
Affiliation(s)
- Antonio Pifferi
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, Milan I-20133, ItalybIstituto di Fotonica e Nanotecnologie, Consiglio Nazionale per le Ricerche, Piazza Leonardo da Vinci 32, Milan I-20133, Italy
| | - Davide Contini
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, Milan I-20133, Italy
| | - Alberto Dalla Mora
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, Milan I-20133, Italy
| | - Andrea Farina
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale per le Ricerche, Piazza Leonardo da Vinci 32, Milan I-20133, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale per le Ricerche, Piazza Leonardo da Vinci 32, Milan I-20133, Italy
| | - Alessandro Torricelli
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, Milan I-20133, ItalybIstituto di Fotonica e Nanotecnologie, Consiglio Nazionale per le Ricerche, Piazza Leonardo da Vinci 32, Milan I-20133, Italy
| |
Collapse
|
7
|
Lemaillet P, Bouchard JP, Hwang J, Allen DW. Double-integrating-sphere system at the National Institute of Standards and Technology in support of measurement standards for the determination of optical properties of tissue-mimicking phantoms. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:121310. [PMID: 26505172 DOI: 10.1117/1.jbo.20.12.121310] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Accepted: 09/29/2015] [Indexed: 05/22/2023]
Abstract
There is a need for a common reference point that will allow for the comparison of the optical properties of tissue-mimicking phantoms. After a brief review of the methods that have been used to measure the phantoms for a contextual backdrop to our approach, this paper reports on the establishment of a standardized double-integrating-sphere platform to measure absorption and reduced scattering coefficients of tissue-mimicking biomedical phantoms. The platform implements a user-friendly graphical user interface in which variations of experimental configurations and model-based analysis are implemented to compute the coefficients based on a modified inverse adding-doubling algorithm allowing a complete uncertainty evaluation. Repeatability and validation of the measurement results of solid phantoms are demonstrated for three samples of different thicknesses, d = 5.08 mm, 7.09 mm, and 9.92 mm, with an absolute error estimate of 4.0% to 5.0% for the absorption coefficient and 11% to 12% for the reduced scattering coefficient (k = 2). The results are in accordance with those provided by the manufacturer. Measurements with different polarization angles of the incident light are also presented, and the resulting optical properties were determined to be equivalent within the estimated uncertainties.
Collapse
Affiliation(s)
- Paul Lemaillet
- National Institute of Standards and Technology, Physical Measurement Laboratory, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | | | - Jeeseong Hwang
- National Institute of Standards and Technology, Physical Measurement Laboratory, 325 Broadway Street, Boulder, Colorado 80305, United States
| | - David W Allen
- National Institute of Standards and Technology, Physical Measurement Laboratory, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| |
Collapse
|
8
|
Khoptyar D, Subash AA, Johansson S, Saleem M, Sparén A, Johansson J, Andersson-Engels S. Broadband photon time-of-flight spectroscopy of pharmaceuticals and highly scattering plastics in the VIS and close NIR spectral ranges. OPTICS EXPRESS 2013; 21:20941-53. [PMID: 24103967 DOI: 10.1364/oe.21.020941] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We present extended spectroscopic analysis of pharmaceutical tablets in the close near infrared spectral range performed using broadband photon time-of-flight (PTOF) absorption and scattering spectra measurements. We show that the absorption spectra can be used to perform evaluation of the chemical composition of pharmaceutical tablets without need for chemo-metric calibration. The spectroscopic analysis was performed using an advanced PTOF spectrometer operating in the 650 to 1400 nm spectral range. By employing temporal stabilization of the system we achieve the high precision of 0.5% required to evaluate the concentration of tablet ingredients. In order to further illustrate the performance of the system, we present the first ever reported broadband evaluation of absorption and scattering spectra from pure and doped Spectralon®.
Collapse
|
9
|
Tu H, Boppart SA. Coherent fiber supercontinuum for biophotonics. LASER & PHOTONICS REVIEWS 2013; 7:10.1002/lpor.201200014. [PMID: 24358056 PMCID: PMC3864867 DOI: 10.1002/lpor.201200014] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2012] [Accepted: 07/05/2012] [Indexed: 05/17/2023]
Abstract
Biophotonics and nonlinear fiber optics have traditionally been two independent fields. Since the discovery of fiber-based supercontinuum generation in 1999, biophotonics applications employing incoherent light have experienced a large impact from nonlinear fiber optics, primarily because of the access to a wide range of wavelengths and a uniform spatial profile afforded by fiber supercontinuum. However, biophotonics applications employing coherent light have not benefited from the most well-known techniques of supercontinuum generation for reasons such as poor coherence (or high noise), insufficient controllability, and inadequate portability. Fortunately, a few key techniques involving nonlinear fiber optics and femtosecond laser development have emerged to overcome these critical limitations. Despite their relative independence, these techniques are the focus of this review, because they can be integrated into a low-cost portable biophotonics source platform. This platform can be shared across many different areas of research in biophotonics, enabling new applications such as point-of-care coherent optical biomedical imaging.
Collapse
Affiliation(s)
- Haohua Tu
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Stephen A Boppart
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
10
|
Farina A, Bargigia I, Taroni P, Pifferi A. Note: Comparison between a prism-based and an acousto-optic tunable filter-based spectrometer for diffusive media. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:016109. [PMID: 23387715 DOI: 10.1063/1.4789312] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This paper compares two continuously tunable systems for time-resolved spectroscopy of diffusive media based on a supercontinuum laser source. Two approaches for spectral selection are considered relying either on a dispersive prism or on a commercial acoustic-optic tunable filter (AOTF) device. The comparison was performed first in terms of extracted power and spectral response function, then in terms of distortions introduced in the retrieved absorption and scattering spectra. Simulations and experiments on diffusive phantoms confirmed that, besides narrower FWHM in the AOTF bandpass, the prism solution is superior with respect to the distortions produced on the recovered spectra.
Collapse
Affiliation(s)
- A Farina
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza L. da Vinci 32, I-20133 Milano, Italy.
| | | | | | | |
Collapse
|
11
|
Bargigia I, Tosi A, Bahgat Shehata A, Della Frera A, Farina A, Bassi A, Taroni P, Dalla Mora A, Zappa F, Cubeddu R, Pifferi A. Time-resolved diffuse optical spectroscopy up to 1700 nm by means of a time-gated InGaAs/InP single-photon avalanche diode. APPLIED SPECTROSCOPY 2012; 66:944-50. [PMID: 22800436 DOI: 10.1366/11-06461] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We present a new compact system for time-domain diffuse optical spectroscopy of highly scattering media operating in the wavelength range from 1100 nm to 1700 nm. So far, this technique has been exploited mostly up to 1100 nm: we extended the spectral range by means of a pulsed supercontinuum light source at a high repetition rate, a prism to spectrally disperse the radiation, and a time-gated InGaAs/InP single-photon avalanche diode working up to 1700 nm. A time-correlated single-photon counting board was used as processing electronics. The system is characterized by linear behavior up to absorption values of about 3.4 cm(-1) where the relative error is 17%. A first measurement performed on lipids is presented: the absorption spectrum shows three major peaks at 1200 nm, 1400 nm, and 1700 nm.
Collapse
Affiliation(s)
- Ilaria Bargigia
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Bogdanov AA, Metelev V, Zhang S, Kumar ATN. Sensing of transcription factor binding via cyanine dye pair fluorescence lifetime changes. MOLECULAR BIOSYSTEMS 2012; 8:2166-73. [PMID: 22710322 DOI: 10.1039/c2mb25057h] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
We designed and synthesized sensors for imaging transcription factor-DNA interactions using a complementary pair of 21-base pair long oligonucleotides (ODNs) carrying two internucleoside phosphate-linked cyanine fluorophores that can either engage in Förster's resonance energy transfer (FRET) with fluorescence emission or assemble into a ground state quenched dimer with short fluorescence lifetimes (FL). Cyanine fluorophores were linked to ODNs within the NF-κB binding site. These sensors were tested in the presence of recombinant p50 and p65 NF-κB proteins or constitutively NF-κB activating HeLa cell lysates. By using a coherent light excitation source we followed changes in fluorescence lifetime of the donor (Cy5.5) at the donor's excitation and emission light wavelengths, as well as the acceptor (800CW or Cy7 cyanine fluorophores) in FRET mode. We observed increases in the donor lifetime in both emitting (0.08-0.15 ns) and non-emitting quenched (0.21 ns) sensors in response to protein binding. The measurements of lifetimes in FRET mode in quenched pair-carrying ODN duplex sensors showed significant differences in FL of the acceptor cyanine fluorophore between NF-κB-containing and NF-κB-free samples but not in control sensors with ODN sequences that have decreased binding affinity to NF-κB. We anticipate that the observed effects will be instrumental for developing sensors enabling non-invasive imaging in cells that undergo activation of NF-κB.
Collapse
Affiliation(s)
- Alexei A Bogdanov
- The Laboratory of Molecular Imaging Probes S6-434, Department of Radiology, University of Massachusetts Medical School, 55 Lake Ave North, Worcester, MA 01655, USA.
| | | | | | | |
Collapse
|
13
|
Svensson T, Alerstam E, Khoptyar D, Johansson J, Folestad S, Andersson-Engels S. Near-infrared photon time-of-flight spectroscopy of turbid materials up to 1400 nm. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2009; 80:063105. [PMID: 19566194 DOI: 10.1063/1.3156047] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Photon time-of-flight spectroscopy (PTOFS) is a powerful tool for analysis of turbid materials. We have constructed a time-of-flight spectrometer based on a supercontinuum fiber laser, acousto-optical tunable filtering, and an InP/InGaAsP microchannel plate photomultiplier tube. The system is capable of performing PTOFS up to 1400 nm, and thus covers an important region for vibrational spectroscopy of solid samples. The development significantly increases the applicability of PTOFS for analysis of chemical content and physical properties of turbid media. The great value of the proposed approach is illustrated by revealing the distinct absorption features of turbid epoxy resin. Promising future applications of the approach are discussed, including quantitative assessment of pharmaceuticals, powder analysis, and calibration-free near-infrared spectroscopy.
Collapse
Affiliation(s)
- Tomas Svensson
- Department of Physics, Lund University, P.O. Box 118, S-221 00 Lund, Sweden
| | | | | | | | | | | |
Collapse
|
14
|
Farina A, Bassi A, Pifferi A, Taroni P, Comelli D, Spinelli L, Cubeddu R. Bandpass effects in time-resolved diffuse spectroscopy. APPLIED SPECTROSCOPY 2009; 63:48-56. [PMID: 19146718 DOI: 10.1366/000370209787169795] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
This paper discusses the spectral distortions occurring when time-resolved spectroscopy of diffusive media is performed illuminating with a wide bandpass. It is shown that the spectral region within the bandpass that exhibits the lowest absorption will dominate the resulting time-resolved curve, leading to significant underestimations of absorption as well as distortions in the spectral shape (including shifts in peak positions). Due to the nonlinear behavior of absorption, this effect becomes even more pronounced when including longer and longer photon path lengths. First, a theoretical treatment of the problem is given, and then the distortion is described by time-resolved reflectance simulations and experimental measurements of lipid and water samples. A spectrally constrained data analysis is proposed that takes into account the spectrum of the light injected into the sample, used to overcome the distortion and improve the accuracy of the estimation of chromophore concentrations from absorption spectra. Measurements on a lipid sample show a reduction of the error from 30% to 6%.
Collapse
Affiliation(s)
- A Farina
- IIT, CNR-INFM and CNR-IFN, Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.
| | | | | | | | | | | | | |
Collapse
|
15
|
Torricelli A, Spinelli L, Contini D, Vanoli M, Rizzolo A, Eccher Zerbini P. Time-resolved reflectance spectroscopy for non-destructive assessment of food quality. ACTA ACUST UNITED AC 2008. [DOI: 10.1007/s11694-008-9036-2] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
16
|
Pifferi A, Torricelli A, Taroni P, Comelli D, Bassi A, Cubeddu R. Fully automated time domain spectrometer for the absorption and scattering characterization of diffusive media. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2007; 78:053103. [PMID: 17552808 DOI: 10.1063/1.2735567] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
We describe a system for absorption and scattering spectroscopy of diffusive media based on time-resolved reflectance and transmittance measurements. The system is operated with mode-locked lasers tunable in the 550-1050 nm spectral range and on a detection chain based on time-correlated single-photon counting. All measurement procedures such as laser tuning and optimization, signal conditioning, data acquisition, and analysis are completely automated, permitting spectral measurements over the whole range in a few minutes. The criticalities of the system are discussed together with the strategies to compensate them. The Medphot protocol devised for the characterization of photon migration instruments was applied to assess the system performances in terms of accuracy, linearity, noise, stability, and reproducibility. Finally, an example of application of the instrument to the spectroscopy of powders is presented.
Collapse
Affiliation(s)
- Antonio Pifferi
- ULTRAS-CNR-INFM and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy.
| | | | | | | | | | | |
Collapse
|
17
|
Bassi A, Spinelli L, D'Andrea C, Giusto A, Swartling J, Pifferi A, Torricelli A, Cubeddu R. Feasibility of white-light time-resolved optical mammography. JOURNAL OF BIOMEDICAL OPTICS 2006; 11:054035. [PMID: 17092184 DOI: 10.1117/1.2355663] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We demonstrate the feasibility of white-light time-resolved optical mammography. The instrumentation is based on supercontinuum light generated in photonic crystal fiber and 32-channel parallel time-correlated single-photon-counting detection. Total measurement time is of the order of 10 min for typical clinical applications. Preliminary measurements performed on volunteers show the ability of the system to determine tissue constituent concentrations and structure over the entire breast area. Furthermore, measurements on a tissue-like sample demonstrate detection and characterization of inclusions.
Collapse
Affiliation(s)
- Andrea Bassi
- ULTRAS-CNR-INFM and CNR-IFN, Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Swartling J, Bassi A, D'Andrea C, Pifferi A, Torricelli A, Cubeddu R. Dynamic time-resolved diffuse spectroscopy based on supercontinuum light pulses. APPLIED OPTICS 2005; 44:4684-92. [PMID: 16075881 DOI: 10.1364/ao.44.004684] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We present a detailed characterization of a system for fast time-resolved spectroscopy of turbid media based on supercontinuum generation in a photonic crystal fiber. The light source provides subpicosecond pulses in the 550-1000-nm spectral range, at 85 MHz, at an average power of up to 50 mW. Wavelength-resolved detection is accomplished by means of a spectrometer coupled to a 16-channel, multianode photomultiplier tube, giving a resolution of 4.5-35 nm/channel, depending on the grating. Time-dispersion curves are acquired with time-correlated single-photon counting, and absorption and reduced scattering coefficients are determined by fitting the data to the diffusion equation. We characterized the system by measuring the time-resolved diffuse reflectance of epoxy phantoms and by assessing the performance in terms of accuracy, linearity, noise sensitivity, stability, and reproducibility. The results were similar to those from previous systems, whereas the full-spectrum (610-810 nm) acquisition time was as short as 1 s owing to the parallel acquisition. We also present the first in vivo real-time dynamic spectral measurements showing tissue oxygenation changes in the arm of a human subject.
Collapse
Affiliation(s)
- Johannes Swartling
- ULTRAS-INFM, IFN-CNR, Dipartimento di Fisica, Politecnico di Milano, P. L. da Vinci 32, I-20133 Milano, Italy.
| | | | | | | | | | | |
Collapse
|