1
|
Fluorescent quantum dot-based nanotool for targeted identification and evaluation of the schistosomiasis circulating cathodic antigen in tissue samples. Micron 2024; 183:103658. [PMID: 38788484 DOI: 10.1016/j.micron.2024.103658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2024] [Revised: 05/09/2024] [Accepted: 05/09/2024] [Indexed: 05/26/2024]
Abstract
Schistosomiasis represents a serious public health problem, a disease for which the circulating cathodic antigen (CCA) is a relevant biomarker. Quantum dots (QDs) are advantageous fluorescent nanoparticles that can be used as specific nanoprobes. In this study, a nanotool based on QDs and anti-CCA antibodies was developed, which, in association with fluorescence microscopy, was applied to trace and evaluate the CCA profile in schistosomiasis-infected tissue samples. Kidney and liver tissues from mice at different disease phases were used as models. QDs and the conjugates were characterized by absorption and emission spectroscopies. Microscopy analyses were used to map and assess CCA accumulation in infected tissue slices in respect to non-infected control samples. The fluorescent microplate assay (FMA) and Zeta potential (ζ) analyses indicated an effective conjugation, which was corroborated by the absence of labeling in non-infected tissue slices (which lack CCA) after incubation with the nanoprobe. Infected liver and kidney tissues exhibited notable staining by the QDs-anti-CCA conjugate. The CCA accumulation increased as follows: 30 < 60 = 120 days post-infection, with 30, 60, and 120 days corresponding to the pre-patent, acute, and beginning of chronic disease phases, respectively. Therefore, this innovative approach, combining imaging acquisition with the sensitivity and specificity of the QDs-anti-CCA conjugate, demonstrated efficiency in locating and comparatively evaluating CCA deposition in biological samples, thereby opening new possibilities for schistosomiasis research.
Collapse
|
2
|
A Mini-Review on Elisa-Based Diagnosis of Schistosomiasis. Curr Mol Med 2024; 24:585-598. [PMID: 37143281 DOI: 10.2174/1566524023666230504140828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 03/06/2023] [Accepted: 03/08/2023] [Indexed: 05/06/2023]
Abstract
BACKGROUND Schistosomiasis is a neglected tropical parasitic disease caused by trematode worms of the genus schistosoma, which affects approximately 240 million people worldwide. the diagnosis of the disease can be performed by parasitological, molecular, and/or immunological methods, however, the development of new diagnostic methods still essential to guide policy decisions, monitor disease trends and assess the effectiveness of interventions. OBJECTIVE in this sense, the current work summarizes the findings of a systematic review regarding antigens applied in the enzyme-linked immunosorbent assay test, which were patented and published over the last ten years. METHODS the literature search strategy used medical subject heading (mesh) terms to define as descriptors. "schistosoma mansoni" was used in arrangement with the descriptors "immunoassay", "enzyme-linked immunosorbent assay", "elisa", and "antigens", using the "and" connector. the patent search was done using keywords, including diagnosis and schistosoma or schistosomiasis or schistosome. several databases were employed for the patent search, such as intellectual property national institute; european patent office; the united states patent and trademark office; patent scope, and google patents. RESULTS forty-one articles were retrieved, of which only five met the eligibility criteria. seventeen patents were taken from the databases, and a brief description of the most relevant inventions is given here. CONCLUSION schistosomiasis is considered the most important helminthic disease in worldwide. therefore, it is important to of searching for and develops diagnostic methods based on serology to reduce morbidity and mortality caused by the disease.
Collapse
|
3
|
Evaluation of isotype-based serology for diagnosis of Schistosoma mansoni infection in individuals living in endemic areas with low parasite burden. Acta Trop 2023; 248:107017. [PMID: 37774894 DOI: 10.1016/j.actatropica.2023.107017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 08/31/2023] [Accepted: 09/01/2023] [Indexed: 10/01/2023]
Abstract
Intestinal schistosomiasis is a chronic and debilitating disease that affects public health systems worldwide. Control interventions to reduce morbidity primarily involve the diagnosis and treatment of infected individuals. However, the recommended Kato-Katz (KK) parasitological method shows low sensitivity in individuals with low parasite loads and is not useful for monitoring elimination of parasite transmission at later stages. In the current study, we evaluated the accuracy of serum reactivity levels of different immunoglobulin isotypes in an enzyme-linked immunosorbent assay (ELISA), utilizing Schistosoma mansoni crude extracts, with the aim to improve the diagnosis of infected individuals with low parasite loads. The serum reactivity of IgM and IgG subclass antibodies (IgG1, IgG3, and IgG4) against soluble adult worm and egg antigen preparations was evaluated in residents from a schistosomiasis-endemic area in northern Minas Gerais, Brazil. The parasitological status of the study population was determined through fecal examination with multiple parasitological tests to create a consolidated reference standard (CRS) plus a fecal DNA detection test (q-PCR). Twelve months after praziquantel treatment, a second serum sample was obtained from the population for reexamination. A two-graph receiver operating characteristic curve (TG-ROC) analysis was performed using the serum reactivity of non-infected endemic controls and egg-positive individuals, and the cut-off value was established based on the intersection point of the sensibility and specificity curves in TG-ROC analyses. The diagnostic accuracy of each serological test was evaluated in relation to the parasitological CRS and to the combination of CRS plus qPCR results. The data revealed that serum reactivity of IgM and IgG3 against S. mansoni antigens did not allow identification of infected individuals from the endemic area. In contrast, serum IgG1 and IgG4-reactivity against schistosome antigens could distinguish between infected and non-infected individuals, with AUC values ranging between 0.728-0.925. The reactivity of IgG4 anti-soluble egg antigen - SEA (sensitivity 79 %, specificity 69 %, kappa = 0.49) had the best diagnostic accuracy, showing positive reactivity in more than 75 % of the infected individuals who eliminated less than 12 eggs per gram of feces. Moreover, serum IgG4 reactivity against SEA and against soluble worm antigen preparation (SWAP) was significantly reduced in the serum of infected individuals after 12 months of confirmed parasitological cure and in the absence of re-infection. These results reinforce that the described IgG4 anti-SEA ELISA assay is a sensitive alternative for the diagnosis of active intestinal schistosomiasis in individuals from endemic areas, including in those with a very low parasite load.
Collapse
|
4
|
Development and evaluation of an indirect ELISA using a multiepitope antigen for the diagnosis of intestinal schistosomiasis. Parasitology 2023; 150:683-692. [PMID: 37092694 PMCID: PMC10410369 DOI: 10.1017/s0031182023000409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/29/2023] [Accepted: 04/15/2023] [Indexed: 04/25/2023]
Abstract
The laboratory diagnosis of intestinal schistosomiasis, carried out by detecting parasite eggs in feces, has low sensitivity when applied to individuals with low parasitic load. Serological tests can be more sensitive for the diagnosis of the disease. Therefore, the objective of this work was to develop and evaluate an ELISA-based immunoenzymatic assay, using a Schistosoma mansoni multiepitope antigen (ELISA IgG anti-SmME). For this, the amino acid sequences of S. mansoni cathepsin B and asparaginyl endopeptidase were submitted to the prediction of B cell epitopes and, together with peptide sequences obtained from earlier works, were used in the construction of a minigene. The multiepitope protein was expressed in Escherichia coli and the performance of the ELISA IgG anti-SmME for schistosomiasis was evaluated using serum samples from 107 individuals either egg positive or negative. In addition, 11 samples from individuals with other helminth infections were included. The ELISA IgG anti-SmME showed a sensitivity of 81.1% and a specificity of 46.1%. Further analysis revealed a 77.2% sensitivity in diagnosis of individuals with egg counts of ≤12 epg (eggs per gram feces) and 87.5% for individuals with 13–99 epg. It is worth mentioning that, to our knowledge, this was the first study using a multiepitope recombinant antigen in an ELISA for diagnosis of intestinal schistosomiasis, which demonstrated promising results in the diagnosis of individuals with low parasitic loads.
Collapse
|
5
|
Anti-mitochondrial Tryparedoxin Peroxidase Monoclonal Antibody-Based Immunohistochemistry for Diagnosis of Cutaneous Leishmaniasis. Front Microbiol 2022; 12:790906. [PMID: 35295679 PMCID: PMC8918995 DOI: 10.3389/fmicb.2021.790906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 12/27/2021] [Indexed: 11/13/2022] Open
Abstract
Cutaneous leishmaniasis (CL) remains a globally spreading public health problem. Among Latin America countries, Brazil has the greatest number of recorded CL cases with several Leishmania species being associated with human cases. Laboratory diagnosis is one of the major challenges to disease control due to the low accuracy of parasitological techniques, the restricted use of molecular techniques, and the importance of differential diagnosis with regard to several dermatological and systemic diseases. In response, we have developed and validated an immunohistochemistry (IHC) technique for CL diagnosis using anti-mTXNPx monoclonal antibody (mAb). Recombinant Leishmania–mTXNPx was produced and used as an immunogen for mAb production through the somatic hybridization technique. The viability of mAb labeling of Leishmania amastigotes was tested by IHC performed with skin biopsies from hamsters experimentally infected with Leishmania amazonensis, Leishmania braziliensis, and Leishmania guyanensis. The enzymes horseradish peroxidase (IHC-HRP) and alkaline phosphatase (IHC-AP), both biotin-free polymer detection systems, were used in the standardization step. The IHC was further validated with skin biopsies from 49 CL patients diagnosed by clinical examination and quantitative real-time polymerase chain reaction and from 37 patients presenting other dermatological infectious diseases. Other parasitological techniques, such as direct examination and culture, were also performed for confirmed CL patients. Histopathology and IHC were performed for all included patients. Overall, the highest sensitivity was observed for IHC-AP (85.7%), followed by IHC-HRP (79.6%), direct examination (77.6%), histopathological examination (HE; 65.3%), and in vitro culture (49%). Only IHC and HE presented specificity over 90% and were able to detect CL patients regardless of parasite burden (odds ratio > 1.94; 95%CI: 0.34–11.23). A significant increase in positivity rates was observed when IHC-AP was combined with direct examination (95.9%) and HE (93.9%). The IHC techniques evaluated in here detected the main Leishmania species causing CL in Brazil and can support diagnostic strategies for controlling this neglected disease, especially if used in combination with other approaches for an integrative laboratorial diagnosis.
Collapse
|
6
|
Schistosomiasis: from established diagnostic assays to emerging micro/nanotechnology-based rapid field testing for clinical management and epidemiology. PRECISION NANOMEDICINE 2019. [DOI: 10.33218/prnano3(1).191205.1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Schistosomiasis is a neglected invasive worm disease with a huge disease burden in developing countries, particularly in children, and is seen increasingly in non-endemic regions through transfer by travellers, expatriates, and refugees. Undetected and untreated infections may be responsible for the persistence of transmission. Rapid and accurate diagnosis is the key to treatment and control. So far, parasitological detection methods remain the cornerstone of Schistosoma infection diagnosis in endemic regions, but conventional tests have limited sensitivity, in particular in low-grade infection. Recent advances contribute to improved detection in clinical and field settings. The recent progress in micro- and nanotechnologies opens a road by enabling the design of new miniaturized point-of-care devices and analytical platforms, which can be used for the rapid detection of these infections. This review starts with an overview of currently available laboratory tests and their performance and then discusses emerging rapid and micro/nanotechnologies-based tools. The epidemiological and clinical setting of testing is then discussed as an important determinant for the selection of the best analytical strategy in patients suspected to suffer from Schistosoma infection. Finally, it discusses the potential role of advanced technologies in the setting near to disease eradication is examined.
Collapse
|
7
|
Diagnosis of Schistosoma mansoni infections: what are the choices in Brazilian low-endemic areas? Mem Inst Oswaldo Cruz 2019; 114:e180478. [PMID: 30942278 PMCID: PMC6440364 DOI: 10.1590/0074-02760180478] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Accepted: 02/21/2019] [Indexed: 12/25/2022] Open
Abstract
The population of Brazil is currently characterised by many individuals harbouring low-intensity Schistosoma mansoni infections. The Kato-Katz technique is the diagnostic method recommended by the World Health Organization (WHO) to assess these infections, but this method is not sensitive enough in the context of low egg excretion. In this regard, potential alternatives are being employed to overcome the limits of the Kato-Katz technique. In the present review, we evaluated the performance of parasitological and immunological approaches adopted in Brazilian areas. Currently, the diagnostic choices involve a combination of strategies, including the utilisation of antibody methods to screen individuals and then subsequent confirmation of positive cases by intensive parasitological investigations.
Collapse
|
8
|
Serological proteomic screening and evaluation of a recombinant egg antigen for the diagnosis of low-intensity Schistosoma mansoni infections in endemic area in Brazil. PLoS Negl Trop Dis 2019; 13:e0006974. [PMID: 30870412 PMCID: PMC6472831 DOI: 10.1371/journal.pntd.0006974] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 04/18/2019] [Accepted: 02/13/2019] [Indexed: 11/22/2022] Open
Abstract
Background Despite decades of use of control programs, schistosomiasis remains a global public health problem. To further reduce prevalence and intensity of infection, or to achieve the goal of elimination in low-endemic areas, there needs to be better diagnostic tools to detect low-intensity infections in low-endemic areas in Brazil. The rationale for development of new diagnostic tools is that the current standard test Kato-Katz (KK) is not sensitive enough to detect low-intensity infections in low-endemic areas. In order to develop new diagnostic tools, we employed a proteomics approach to identify biomarkers associated with schistosome-specific immune responses in hopes of developing sensitive and specific new methods for immunodiagnosis. Methods and findings Immunoproteomic analyses were performed on egg extracts of Schistosoma mansoni using pooled sera from infected or non-infected individuals from a low-endemic area of Brazil. Cross reactivity with other soil-transmitted helminths (STH) was determined using pooled sera from individuals uniquely infected with different helminths. Using this approach, we identified 23 targets recognized by schistosome acute and chronic sera samples. To identify immunoreactive targets that were likely glycan epitopes, we compared these targets to the immunoreactivity of spots treated with sodium metaperiodate oxidation of egg extract. This treatment yielded 12/23 spots maintaining immunoreactivity, suggesting that they were protein epitopes. From these 12 spots, 11 spots cross-reacted with sera from individuals infected with other STH and 10 spots cross-reacted with the negative control group. Spot number 5 was exclusively immunoreactive with sera from S. mansoni-infected groups in native and deglycosylated conditions and corresponds to Major Egg Antigen (MEA). We expressed MEA as a recombinant protein and showed a similar recognition pattern to that of the native protein via western blot. IgG-ELISA gave a sensitivity of 87.10% and specificity of 89.09% represented by area under the ROC curve of 0.95. IgG-ELISA performed better than the conventional KK (2 slides), identifying 56/64 cases harboring 1–10 eggs per gram of feces that were undiagnosed by KK parasitological technique. Conclusions The serological proteome approach was able to identify a new diagnostic candidate. The recombinant egg antigen provided good performance in IgG-ELISA to detect individuals with extreme low-intensity infections (1 egg per gram of feces). Therefore, the IgG-ELISA using this newly identified recombinant MEA can be a useful tool combined with other techniques in low-endemic areas to determine the true prevalence of schistosome infection that is underestimated by the KK method. Further, to overcome the complexity of ELISA in the field, a second generation of antibody-based rapid diagnostic tests (RDT) can be developed. Schistosomiasis remains a serious global public health problem. Detecting parasite eggs in patient stool samples using the KK method is the standard diagnostic recommended by the World Health Organization (WHO) for infection by S. mansoni. As a result of intensive control strategies, many previously high-endemic areas are now considered low-endemic areas and the KK method does not function well in low-endemic areas and therefore cannot be considered the gold standard. Thus, a new emphasis on strategies to accurately diagnose low-intensity infections was outlined in a plan from the WHO focusing on elimination of disease as a public health problem. Successful diagnoses and treatment of infected individuals may result in eradication of low-burden transmitters and consequently contribute to interruption of disease transmission. In this regard, immunological techniques have proven to be more sensitive and promising for identifying low-intensity infections where KK may be negative. The identification of antigens is the initial step for developing new immunodiagnostic assays. In this study, we used sets of pooled human sera samples from controls with acute and chronic infections to identify new target antigens via proteomic screening. Using these approaches, we initially identified 12 different egg proteins in S. mansoni-infected individuals (acute and chronic phase). A single antigen, identified as MEA, was shown to be highly specific as this antigen was not recognized by sera from negative patients or patients infected with other STH. The recombinant MEA protein functioned in an ELISA as a highly sensitive and specific antigen to detect patient IgG-antibodies. Recombinant MEA performed significantly better to detect low-intensity infections (1 egg per gram of feces) than the KK method using 2 slides. Therefore, we were able to use a proteomic screening approach to identify a potential new candidate antigen for development of far more sensitive diagnostic assays. Further diagnostic assays employing the MEA could be useful tools on their own or in combination with other methods for diagnosis of schistosome infection in populations living in extreme low-intensity endemic areas of Brazil.
Collapse
|
9
|
Serological approaches for the diagnosis of schistosomiasis - A review. Mol Cell Probes 2016; 31:2-21. [PMID: 27986555 DOI: 10.1016/j.mcp.2016.12.003] [Citation(s) in RCA: 77] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Revised: 11/28/2016] [Accepted: 12/12/2016] [Indexed: 01/14/2023]
Abstract
Schistosomiasis is a common disease in endemic areas of Sub-Saharan Africa, South America and Asia. It is rare in Europe, mainly imported from endemic countries due to travelling or human migration. Available methods for the diagnosis of schistosomiasis comprise microscopic, molecular and serological approaches, with the latter detecting antigens or antibodies associated with Schistosoma spp. infection. The serological approach is a valuable screening tool in low-endemicity settings and for travel medicine, though the interpretation of any diagnostic results requires knowledge of test characteristics and a patient's history. Specific antibody detection by most currently used assays is only possible in a relatively late stage of infection and does not allow for the differentiation of acute from previous infections for therapeutic control or the discrimination between persisting infection and re-infection. Throughout the last decades, new target antigens have been identified, and assays with improved performance and suitability for use in the field have been developed. For numerous assays, large-scale studies are still required to reliably characterise assay characteristics alone and in association with other available methods for the diagnosis of schistosomiasis. Apart from S. mansoni, S. haematobium and S. japonicum, for which most available tests were developed, other species of Schistosoma that occur less frequently need to be taken into account. This narrative review describes and critically discusses the results of published studies on the evaluation of serological assays that detect antibodies against different Schistosoma species of humans. It provides insights into the diagnostic performance and an overview of available assays and their suitability for large-scale use or individual diagnosis, and thus sets the scene for serological diagnosis of schistosomiasis and the interpretation of results.
Collapse
|
10
|
Improvement of POC-CCA Interpretation by Using Lyophilization of Urine from Patients with Schistosoma mansoni Low Worm Burden: Towards an Elimination of Doubts about the Concept of Trace. PLoS Negl Trop Dis 2016; 10:e0004778. [PMID: 27326453 PMCID: PMC4915691 DOI: 10.1371/journal.pntd.0004778] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 05/23/2016] [Indexed: 12/05/2022] Open
Abstract
Background Accurate diagnostic techniques for schistosomiasis are essential for prevalence determination and identification of positive patients. A point-of-care test for detecting schistosome circulating cathodic antigen (POC-CCA) has been evaluated for its accuracy in different endemic regions. This reagent strip/dipstick based assay has showed high sensitivity for individuals with high or moderate worm burden, but the interpretation of light infections is less clear, especially for trace readings. Methodology/Principal Findings We introduced a urine lyophilization step to the POC-CCA assay to improve its sensitivity and clarify the interpretation of traces. We evaluated POC-CCA sensitivity and specificity within individuals with low parasite burdens in a Brazilian endemic area where a high number of traces were detected. Patients that were positive for other helminths were also evaluated for cross reactions. In all cases, a combined parasitological diagnosis using Kato-Katz (24 slides) and Saline Gradient (1 g of feces) were used as reference. At baseline, diagnosis by POC-CCA (1–2 cassettes) showed 6% sensitivity, inaccurately predicting a low prevalence of Schistosoma mansoni infections (2 POC-CCA positives/32 egg positives). After urine lyophilization, the sensitivity was increased significantly (p < 0.05). Prevalence rates changed from 2% to 32% (27 POC-CCA positives/32 egg positives), equivalent to parasitological techniques. Most of the trace readings changed to positive after lyophilization while some negatives turned into traces. Cross reaction analysis confirmed the specificity of POC-CCA. Conclusions/Significance Trace readings cannot be primarily defined as positive or negative cases. It is critical to verify case-by-case by concentrating urine 10 fold by lyophilization for the diagnosis. Following lyophilization, persistent trace readings should be read as negatives. No trained technician is needed and cost is restricted to the cost of a lyophilizer and the electricity to run it. Schistosomiasis mansoni is a relevant disease affecting millions of individuals in different countries, in particular countries in Africa, and Brazil. Diagnosis performed by Kato-Katz technique for the detection of eggs in stool and a point-of-care test for circulating cathodic antigen detection in urine (POC-CCA) has been evaluated. Both methods have decreased sensitivity when diagnosing patients with low parasite burdens, which can lead to infected individuals not receiving treatment. Here, we focused on interpretation of POC-CCA results in persons with low parasite burdens. We noted a high number (49%) of indeterminate results, including false negatives and trace readings. A urine concentration step was included to improve the test’s sensitivity. Important differences on sensitivity and prevalence rates were noted when comparing diagnosis by POC-CCA before and after urine concentration. Notably, indeterminate results were easily defined after introduction of this step. Cross reaction analysis confirmed the specificity of POC-CCA, with exceptions noted for individuals with hookworm infection. In conclusion, trace readings cannot be primarily defined as positive or negative cases. It is imperative to analyze each case individually by concentrating urine prior to the introduction of treatment, instead of relying on a point-of-care test with indeterminate results.
Collapse
|
11
|
Abstract
Schistosomiasis is a major neglected tropical disease that afflicts more than 240 million people, including many children and young adults, in the tropics and subtropics. The disease is characterized by chronic infections with significant residual morbidity and is of considerable public health importance, with substantial socioeconomic impacts on impoverished communities. Morbidity reduction and eventual elimination through integrated intervention measures are the focuses of current schistosomiasis control programs. Precise diagnosis of schistosome infections, in both mammalian and snail intermediate hosts, will play a pivotal role in achieving these goals. Nevertheless, despite extensive efforts over several decades, the search for sensitive and specific diagnostics for schistosomiasis is ongoing. Here we review the area, paying attention to earlier approaches but emphasizing recent developments in the search for new diagnostics for schistosomiasis with practical applications in the research laboratory, the clinic, and the field. Careful and rigorous validation of these assays and their cost-effectiveness will be needed, however, prior to their adoption in support of policy decisions for national public health programs aimed at the control and elimination of schistosomiasis.
Collapse
|
12
|
Sensitivity and specificity of multiple Kato-Katz thick smears and a circulating cathodic antigen test for Schistosoma mansoni diagnosis pre- and post-repeated-praziquantel treatment. PLoS Negl Trop Dis 2014; 8:e3139. [PMID: 25211217 PMCID: PMC4161328 DOI: 10.1371/journal.pntd.0003139] [Citation(s) in RCA: 120] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Accepted: 07/22/2014] [Indexed: 12/23/2022] Open
Abstract
Background Two Kato-Katz thick smears (Kato-Katzs) from a single stool are currently recommended for diagnosing Schistosoma mansoni infections to map areas for intervention. This ‘gold standard’ has low sensitivity at low infection intensities. The urine point-of-care circulating cathodic antigen test (POC-CCA) is potentially more sensitive but how accurately they detect S. mansoni after repeated praziquantel treatments, their suitability for measuring drug efficacy and their correlation with egg counts remain to be fully understood. We compared the accuracies of one to six Kato-Katzs and one POC-CCA for the diagnosis of S. mansoni in primary-school children who have received zero to ten praziquantel treatments. We determined the impact each diagnostic approach may have on monitoring and evaluation (M&E) and drug-efficacy findings. Method/Principle Findings In a high S. mansoni endemic area of Uganda, three days of consecutive stool samples were collected from primary school-aged children (six - 12 years) at five time-points in year one: baseline, one-week-post-, four-weeks-post-, six-months-post-, and six-months-one-week-post-praziquantel and three time-points in years two and three: pre-, one-week-post- and four-weeks-post-praziquantel-treatment/retreatment (n = 1065). Two Kato-Katzs were performed on each stool. In parallel, one urine sample was collected and a single POC-CCA evaluated per child at each time-point in year one (n = 367). At baseline, diagnosis by two Kato-Katzs (sensitivity = 98.6%) or one POC-CCA (sensitivity = 91.7%, specificity = 75.0%) accurately predicted S. mansoni infections. However, one year later, a minimum of three Kato-Katzs, and two years later, five Kato-Katzs were required for accurate diagnosis (sensitivity >90%) and drug-efficacy evaluation. The POC-CCA was as sensitive as six Kato-Katzs four-weeks-post and six-months-post-treatment, if trace readings were classified as positive. Conclusions/Significance Six Kato-Katzs (two/stool from three stools) and/or one POC-CCA are required for M&E or drug-efficacy studies. Although unable to measure egg reduction rates, one POC-CCA appears to be more sensitive than six Kato-Katzs at four-weeks-post-praziquantel (drug efficacy) and six-months-post-praziquantel (M&E). Schistosomiasis is a parasitic disease infecting over 200 million people. It remains a major public health concern despite treatment of over 120 million people in sub-Saharan Africa alone. Accurate diagnostic methods are essential for monitoring drug efficacy and long-term control program success. The World Health Organization recommends two Kato-Katz thick smears (Kato-Katzs) from a single stool for Schistosoma mansoni diagnosis to map prevalence and areas for control interventions. Although highly specific, Kato-Katzs are thought to be insensitive at low egg counts. The recently refined urine point-of-care circulating cathodic antigen test (POC-CCA) has been proposed as a diagnostic alternative for mapping areas for interventions, and potentially for assessing drug efficacy. Over three years we assessed the accuracy of six Kato-Katzs and a single POC-CCA in detecting infections in Ugandan primary-school children at 11 time points with repeated praziquantel treatments. Our results demonstrate that two Kato-Katzs accurately detect S. mansoni infection pre-treatment, but at least three days of two Kato-Katzs per stool or one POC-CCA are required for annual monitoring and treatment evaluation and/or drug-efficacy studies. One POC-CCA may be more sensitive in measuring S. mansoni prevalence than six Kato-Katzs, but its accuracies for rigorous intensity measures are still to be proven.
Collapse
|