1
|
Mishra V, Yadav R, Chaudhary S, Pandey L, Pandey A. Retrospective Analysis of Dosimetric Comparison Between Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy in Patients With Esophageal Cancer. Cureus 2025; 17:e76981. [PMID: 39912037 PMCID: PMC11794999 DOI: 10.7759/cureus.76981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/05/2025] [Indexed: 02/07/2025] Open
Abstract
Introduction Esophageal cancer is a significant global health concern, with high incidence and mortality rates, particularly in India, where it ranks among the top causes of cancer-related deaths. Radiotherapy plays a critical role in the treatment of advanced-stage esophageal cancer. This study aims to compare the dosimetric outcomes of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) to evaluate their efficacy and safety in managing mid-esophageal carcinoma. Materials and methods A retrospective study was carried out on thirty patients with middle-third esophageal cancer who received treatment at Rohilkhand Medical College and Hospital, Bareilly, India. The patients, aged between 50 and 70 years (mean age of 66.5 years), were in stages II to III of cancer according to the American Joint Committee on Cancer (AJCC) 2018 guidelines. All patients had histologically confirmed cases of moderately differentiated squamous cell carcinoma. The treatment procedure included immobilization using a thoracic mold, CT simulation with intravenous and oral contrast, and contouring of the gross tumor volume (GTV), clinical target volume (CTV), planning target volume (PTV), and organs at risk (OARs) following the Radiation Therapy Oncology Group (RTOG) 0436 protocol. VMAT planning was done using the Varian Eclipse™ Treatment Planning System, while IMRT planning employed a seven-field non-coplanar beam setup. Comparative virtual IMRT plans were generated for these patients. Both VMAT and IMRT plans were evaluated based on dosimetric parameters for the PTV and OARs. Results Both VMAT and IMRT achieved sufficient PTV coverage, with no statistically significant differences in dosimetric parameters (dose to 99 % volume of PTV, dose to 95 %volume of PTV, maximum dose to PTV, minimum dose to PTV). VMAT demonstrated reduced lung and heart doses compared to IMRT; however, the observed differences were not statistically significant. There was a reduction in lung dose with VMAT when evaluating the dose-volume constraints: volume receiving 15 Gy dose (V15) by 11%, volume receiving 20 Gy dose (V20) by 20%, and volume receiving 25 Gy dose (V25) by 41%, though these differences were not statistically significant. The mean maximum spinal cord dose was significantly lower with VMAT (19.69 Gy) compared to IMRT (30.80 Gy, p=0.01). Heart dosimetry showed slight improvements with VMAT, particularly in volume receiving 30 Gy dose (V30), volume receiving 40 Gy dose (V40), and mean heart dose, though these differences were not statistically significant. Conclusion Both VMAT and IMRT provided similar PTV coverage. VMAT showed a reduction in spinal cord dose, which was statistically significant, and a trend toward lower lung and heart doses, though these differences were not statistically significant. VMAT appears to be an effective option for treating mid-esophageal carcinoma while reducing exposure to critical organs.
Collapse
Affiliation(s)
- Vishwadeep Mishra
- Radiation Oncology, All India Institute of Medical Sciences, Gorakhpur, IND
| | - Rashmi Yadav
- Radiation Oncology, Hind Institute of Medical Sciences, Barabanki, IND
| | | | - Laxman Pandey
- Radiation Oncology, Rohilkhand Medical College and Hospital, Bareilly, IND
| | - Archana Pandey
- Radiation Oncology, Rohilkhand Medical College and Hospital, Bareilly, IND
| |
Collapse
|
2
|
Fukuzawa T, Nagao R, Kuroki T, Mikami T, Akiba T, Nakano Y, Toyoda Y, Takazawa T, Matsumoto Y, Kabuki S, Sugawara A. Clinical outcomes and prognostic factors of volumetric modulated arc therapy (VMAT) of esophageal cancer. Rep Pract Oncol Radiother 2024; 29:426-436. [PMID: 39895953 PMCID: PMC11785388 DOI: 10.5603/rpor.101529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 07/11/2024] [Indexed: 02/04/2025] Open
Abstract
Background The objective was to evaluate the efficacy and safety of radiotherapy and the prognostic factors in patients with esophageal cancer who received definitive radiotherapy, using volumetric modulated arc therapy (VMAT). Materials and methods Forty-seven patients who received definitive radiotherapy using VMAT between September 2017 and December 2020 were enrolled. Prescription doses were 60 Gy in 30 fractions to the planning target volume (PTV) primary and 48 Gy in 30 fractions to the PTV subclinical. Overall survival (OS), progression free survival (PFS), and toxicity were analyzed, and univariate and multivariate analyses were used to investigate the prognostic factors. Results Median follow up time was 10 months. Most of the patients had an advanced disease stage (stage I, 12.8%; II, 8.5%; III, 27.7%; IV, 51.0%) patients (38.3%) had a T4 tumor. The median survival time was 14 months (range: 0-56 months). The 2-year OS and PFS were 31.3% and 20.4%, respectively. Acute adverse events (≥ Grade 3) were observed in 25 patients (53.2%), and the most frequent types were dysphagia, hematological toxicities including leukopenia, and febrile neutropenia in 14 (29.8%), 10 (21%), and 10 (21%) patients, respectively. Late adverse events (Grade 3 or higher) were observed in eight patients (17.0%), and the most frequent types were pneumonitis in four patients (8.5%), and Grade 5 in one patient (2.1%; esophageal fistula). In multivariate analysis, neutrophil-to-lymphocyte ratio (NLR) > 3 (p = 0.026) was significantly associated with poor survival. Conclusion Definitive radiotherapy of 60Gy with VMAT is feasible and safe for patients with esophageal cancer. Pre-treatment NLR >3 was an independent prognostic factor for OS.
Collapse
Affiliation(s)
- Tsuyoshi Fukuzawa
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Ryuta Nagao
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Toshihisa Kuroki
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Tatsuya Mikami
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Takeshi Akiba
- Department of Radiation Oncology, Tokai University School of Medicine Hachioji Hospital, Tokyo, Japan
| | - Yoji Nakano
- Department of Radiation Oncology, Tokai University School of Medicine Hachioji Hospital, Tokyo, Japan
| | - Yuri Toyoda
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Tsuyoshi Takazawa
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Yoshitsugu Matsumoto
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Shigeto Kabuki
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| | - Akitomo Sugawara
- Department of Radiation Oncology, Tokai University School of Medicine, Kanagawa, Japan
| |
Collapse
|
3
|
Li Y, Ke Y, Huang X, Zhang R, Su W, Ma H, He P, Cui X, Huang S. Innovative regression model-based decision support tool for optimizing radiotherapy techniques in thoracic esophageal cancer. Front Oncol 2024; 14:1370293. [PMID: 39114310 PMCID: PMC11303316 DOI: 10.3389/fonc.2024.1370293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 06/25/2024] [Indexed: 08/10/2024] Open
Abstract
Background Modern radiotherapy exemplified by intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), has transformed esophageal cancer treatment. Facing challenges in treating thoracic esophageal cancer near vital organs, this study introduces a regression model-based decision support tool for the optimal selection of radiotherapy techniques. Methods We enrolled 106 patients diagnosed with locally advanced thoracic esophageal cancer in this study and designed individualized IMRT and VMAT radiotherapy plans for each patient. Detailed dosimetric analysis was performed to evaluate the differences in dose distribution between the two radiotherapy techniques across various thoracic regions. Single-factor and multifactorial logistic regression analyses were employed to establish predictive models (P1 and P2) and factors such as TLV/PTV ratio. These models were used to predict the compliance and potential advantages of IMRT and VMAT plans. External validation was performed in a validation group of 30 patients. Results Using predictive models, we developed a data-driven decision support tool. For upper thoracic cases, VMAT plans were recommended; for middle/lower thoracic cases, the tool guided VMAT/IMRT choices based on TLV/PTV ratio. Models P1 and P2 assessed IMRT and VMAT compliance. In validation, the tool showed high specificity (90.91%) and sensitivity (78.95%), differentiating IMRT and VMAT plans. Balanced performance in compliance assessment demonstrated tool reliability. Conclusion In summary, our regression model-based decision support tool provides practical guidance for selecting optimal radiotherapy techniques for thoracic esophageal cancer patients. Despite a limited sample size, the tool demonstrates potential clinical benefits, alleviating manual planning burdens and ensuring precise, individualized treatment decisions for patients.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Shan Huang
- Department of Radiation Oncology, the Second Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| |
Collapse
|
4
|
Mu Y, Wang H, Xu L, Shi L, Song R, Wang D, Gao Y, Yan H. Analysis of the therapeutic effect of synchronous integrated intensity modulated radiotherapy combined with chemotherapy in stage IIIc of cervical cancer. Front Oncol 2024; 14:1283991. [PMID: 38884092 PMCID: PMC11177616 DOI: 10.3389/fonc.2024.1283991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 05/09/2024] [Indexed: 06/18/2024] Open
Abstract
Objective To explore the Therapeutic effect of synchronous Integrated intensity modulated radiotherapy combined with chemotherapy in stage IIIc of Cervical Cancer. Methods A total of 58 patients with stage IIIC cervical cancer (KPS ≥ 80) were analyzed in this study. They were admitted to our hospital between August 2017 and August 2022. Synchronous integrated boost intensity-modulated radiotherapy (SIB-IMRT) and sequential boost intensity-modulated radiotherapy (LCB-IMRT) were used to treat pelvic and/or para-aortic metastatic lymph nodes, with 30 cases in the SIB group and 28 cases in the LCB group. Comparison of short-term and long-term efficacy. Comparison of recurrence and metastasis rates, radiation dose to organs at risk and incidence of adverse drug reactions. Result 30 patients were treated with simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT), and 28 patients were treated with sequential boost intensity-modulated radiotherapy (LCB-IMRT). At the completion of radiotherapy and 3 months after radiotherapy, there was no significant difference in clinical efficacy observed between the two treatment groups. The median overall survival (OS), progression-free survival (PFS), and disease-free survival (DMR) in the SIB-IMRT group were significantly higher compared to the LCB-IMRT group. The SIB-IMRT group demonstrated significantly lower rates compared to the LCB-IMRT group. Furthermore, within 3 years and 5 years, the rates of lymph node recurrence, cervical and vaginal local recurrence, and distant metastasis within the radiotherapy field were significantly lower in the SIB-IMRT group compared to the LCB-IMRT group. There were no significant differences observed between the two groups in terms of the maximum dose to the small intestine (Dmax), dose received by 2cc of the small intestine (D2cc), maximum dose to the rectum (Dmax), and dose received by 1cc of the bladder (D1cc). The incidence of bone marrow toxicity in the SIB-IMRT group was significantly lower compared to the LCB-IMRT group. Moreover, the occurrence of grade III and IV bone marrow toxicity was also significantly lower in the SIB-IMRT group compared to the LCB-IMRT group. Conclusion The study has concluded that there is no significant differences in in terms of bladder associated adverse events and gastrointestinal toxicity in both Simultaneous Integrated Boost Intensity-Modulated Radiotherapy and Layered Conical Beam Intensity-Modulated Radiation Therapy.
Collapse
Affiliation(s)
- Yanru Mu
- Radiotherapy Department, Liaoning Health Industry Group Bengang General Hospital, Benxi, Liaoning, China
| | - Hui Wang
- Radiotherapy Department, Liaoning Health Industry Group Bengang General Hospital, Benxi, Liaoning, China
| | - Li Xu
- Radiotherapy Department, Liaoning Health Industry Group Bengang General Hospital, Benxi, Liaoning, China
| | - Li Shi
- Gynaecology and Obstetrics, Liaoning Health Industry Group Bengang General Hospital, Benxi, Liaoning, China
| | - Rui Song
- Gynaecology and Obstetrics, Liaoning Health Industry Group Bengang General Hospital, Benxi, Liaoning, China
| | - Dezhi Wang
- Medical Imaging Department, Liaoning Health Industry Group Bengang General Hospital, Benxi, Liaoning, China
| | - Yuhua Gao
- Gynecology and Oncology Department, Liaoning Cancer Institute and Hospital, Shenyang, Liaoning, China
- Nuclear Medicine, Benxi Central Hospital, Benxi, Liaoning, China
| | - Haibo Yan
- Gynecology and Oncology Department, Liaoning Cancer Institute and Hospital, Shenyang, Liaoning, China
- Nuclear Medicine, Benxi Central Hospital, Benxi, Liaoning, China
| |
Collapse
|
5
|
Acharya R, Mahapatra A, Verma HK, Bhaskar LVKS. Unveiling Therapeutic Targets for Esophageal Cancer: A Comprehensive Review. Curr Oncol 2023; 30:9542-9568. [PMID: 37999111 PMCID: PMC10670555 DOI: 10.3390/curroncol30110691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/19/2023] [Accepted: 10/27/2023] [Indexed: 11/25/2023] Open
Abstract
Esophageal cancer is a highly aggressive and deadly disease, ranking as the sixth leading cause of cancer-related deaths worldwide. Despite advances in treatment, the prognosis remains poor. A multidisciplinary approach is crucial for achieving complete remission, with treatment options varying based on disease stage. Surgical intervention and endoscopic treatment are used for localized cancer, while systemic treatments like chemoradiotherapy and targeted drug therapy play a crucial role. Molecular markers such as HER2 and EGFR can be targeted with drugs like trastuzumab and cetuximab, and immunotherapy drugs like pembrolizumab and nivolumab show promise by targeting immune checkpoint proteins. Epigenetic modifications offer new avenues for targeted therapy. Treatment selection depends on factors like stage, tumor location, and patient health, with post-operative and rehabilitation care being essential. Early diagnosis, appropriate treatment, and supportive care are key to improving outcomes. Continued research is needed to develop effective targeted drugs with minimal side effects. This review serves as a valuable resource for clinicians and researchers dedicated to enhancing esophageal cancer treatment outcomes.
Collapse
Affiliation(s)
- Rakesh Acharya
- Department of Zoology, Guru Ghasidas Vishwavidyalaya, Bilaspur 495009, India; (R.A.); (A.M.)
| | - Ananya Mahapatra
- Department of Zoology, Guru Ghasidas Vishwavidyalaya, Bilaspur 495009, India; (R.A.); (A.M.)
| | - Henu Kumar Verma
- Department of Immunopathology, Institute of lungs Health and Immunity, Comprehensive Pneumology Center, Helmholtz Zentrum, Neuherberg, 85764 Munich, Germany;
| | - L. V. K. S. Bhaskar
- Department of Zoology, Guru Ghasidas Vishwavidyalaya, Bilaspur 495009, India; (R.A.); (A.M.)
| |
Collapse
|
6
|
Fang J, Zhang Q, Liu Y, Yu Y, Jiang T, Wang J, Li X. Correlation analysis of treatment positions and body mass index on acute radiation enteritis for cervical cancer patients underwent volumetric modulated arc therapy. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2023. [DOI: 10.1016/j.jrras.2023.100568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
|
7
|
Xie K, Gao L, Zhang H, Zhang S, Xi Q, Zhang F, Sun J, Lin T, Sui J, Ni X. Inpainting truncated areas of CT images based on generative adversarial networks with gated convolution for radiotherapy. Med Biol Eng Comput 2023:10.1007/s11517-023-02809-y. [PMID: 36897469 DOI: 10.1007/s11517-023-02809-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 02/20/2023] [Indexed: 03/11/2023]
Abstract
This study aimed to inpaint the truncated areas of CT images by using generative adversarial networks with gated convolution (GatedConv) and apply these images to dose calculations in radiotherapy. CT images were collected from 100 patients with esophageal cancer under thermoplastic membrane placement, and 85 cases were used for training based on randomly generated circle masks. In the prediction stage, 15 cases of data were used to evaluate the accuracy of the inpainted CT in anatomy and dosimetry based on the mask with a truncated volume covering 40% of the arm volume, and they were compared with the inpainted CT synthesized by U-Net, pix2pix, and PConv with partial convolution. The results showed that GatedConv could directly and effectively inpaint incomplete CT images in the image domain. For the results of U-Net, pix2pix, PConv, and GatedConv, the mean absolute errors for the truncated tissue were 195.54, 196.20, 190.40, and 158.45 HU, respectively. The mean dose of the planning target volume, heart, and lung in the truncated CT was statistically different (p < 0.05) from those of the ground truth CT ([Formula: see text]). The differences in dose distribution between the inpainted CT obtained by the four models and [Formula: see text] were minimal. The inpainting effect of clinical truncated CT images based on GatedConv showed better stability compared with the other models. GatedConv can effectively inpaint the truncated areas with high image quality, and it is closer to [Formula: see text] in terms of image visualization and dosimetry than other inpainting models.
Collapse
Affiliation(s)
- Kai Xie
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, 213000, China
- Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, 213000, China
| | - Liugang Gao
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, 213000, China
- Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, 213000, China
| | - Heng Zhang
- Center for Medical Physics, Nanjing Medical University, Changzhou, 213003, China
- Key Laboratory of Medical Physics, Changzhou, 213000, China
| | - Sai Zhang
- Center for Medical Physics, Nanjing Medical University, Changzhou, 213003, China
- Key Laboratory of Medical Physics, Changzhou, 213000, China
| | - Qianyi Xi
- Center for Medical Physics, Nanjing Medical University, Changzhou, 213003, China
- Key Laboratory of Medical Physics, Changzhou, 213000, China
| | - Fan Zhang
- Center for Medical Physics, Nanjing Medical University, Changzhou, 213003, China
- Key Laboratory of Medical Physics, Changzhou, 213000, China
| | - Jiawei Sun
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, 213000, China
- Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, 213000, China
| | - Tao Lin
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, 213000, China
- Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, 213000, China
| | - Jianfeng Sui
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, 213000, China
- Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, 213000, China
| | - Xinye Ni
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, 213000, China.
- Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, 213000, China.
- Center for Medical Physics, Nanjing Medical University, Changzhou, 213003, China.
- Key Laboratory of Medical Physics, Changzhou, 213000, China.
| |
Collapse
|
8
|
Hsu CX, Lin KH, Wang SY, Tsai WT, Chang CH, Tien HJ, Shueng PW, Wu TH, Mok GSP. Planning evaluation of a novel volume-based algorithm for personalized optimization of lung dose in VMAT for esophageal cancer. Sci Rep 2022; 12:2513. [PMID: 35169144 PMCID: PMC8847643 DOI: 10.1038/s41598-021-04571-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/20/2021] [Indexed: 11/09/2022] Open
Abstract
Radiotherapy treatment planning (RTP) is time-consuming and labor-intensive since medical physicists must devise treatment plans carefully to reduce damage to tissues and organs for patients. Previously, we proposed the volume-based algorithm (VBA) method, providing optimal partial arcs (OPA) angle to achieve the low-dose volume of lungs in dynamic arc radiotherapy. This study aimed to implement the VBA for esophageal cancer (EC) patients and compare the lung dose and delivery time between full arcs (FA) without using VBA and OPA angle using VBA in volumetric modulated arc therapy (VMAT) plans. We retrospectively included 30 patients diagnosed with EC. RTP of each patient was replanned to 4 VMAT plans, including FA plans without (FA-C) and with (FA + C) dose constraints of OARs and OPA plans without (OPA-C) and with (OPA + C) dose constraints of OARs. The prescribed dose was 45 Gy. The OARs included the lungs, heart, and spinal cord. The dose distribution, dose-volume histogram, monitor units (MUs), delivery time, and gamma passing rates were analyzed. The results showed that the lung V5 and V10 in OPA + C plans were significantly lower than in FA + C plans (p < 0.05). No significant differences were noted in planning target volume (PTV) coverage, lung V15, lung V20, mean lung dose, heart V30, heart V40, mean heart dose, and maximal spinal cord dose between FA + C and OPA + C plans. The delivery time was significantly longer in FA + C plans than in OPA + C plans (237 vs. 192 s, p < 0.05). There were no significant differences between FA + C and OPA + C plans in gamma passing rates. We successfully applied the OPA angle based on the VBA to clinical EC patients and simplified the arc angle selection in RTP. The VBA could provide a personalized OPA angle for each patient and effectively reduce lung V5, V10, and delivery time in VMAT.
Collapse
Affiliation(s)
- Chen-Xiong Hsu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Kuan-Heng Lin
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan.,Industrial Ph.D. Program of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Shan-Ying Wang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Wei-Ta Tsai
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chiu-Han Chang
- Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hui-Ju Tien
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Pei-Wei Shueng
- Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan. .,Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| | - Greta S P Mok
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, SAR, China
| |
Collapse
|
9
|
Shao Y, Chen H, Wang H, Duan Y, Feng A, Huang Y, Gu H, Kong Q, Xu Z. Investigation of Predictors to Achieve Acceptable Lung Dose in T-Shaped Upper and Middle Esophageal Cancer With IMRT and VMAT. Front Oncol 2021; 11:735062. [PMID: 34692508 PMCID: PMC8529030 DOI: 10.3389/fonc.2021.735062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 09/09/2021] [Indexed: 12/24/2022] Open
Abstract
Purpose The purpose of this study is to investigate whether there are predictors and cutoff points that can predict the acceptable lung dose using intensity-modulated radiation therapy (IMRT) and volume-modulated arc therapy (VMAT) in radiotherapy for upper ang middle esophageal cancer. Material and Methods Eighty-two patients with T-shaped upper-middle esophageal cancer (UMEC) were enrolled in this retrospective study. Jaw-tracking IMRT plan (JT-IMRT), full-arc VMAT plan (F-VMAT), and pactial-arc VMAT plan (P-VMAT) were generated for each patient. Dosimetric parameters such as MLD and V20 of total lung were compared among the three plannings. Ten factors such as PCTVinferior length and PCTVinferior length/total lung length were calculated to find the predictors and cutoff points of the predictors. All patients were divided into two groups according to the cutoff points, and the dosimetric differences between the two groups of the three plans were compared. ANOVA, receiver operating characteristic (ROC) analysis, and Mann–Whitney U-test were performed for comparisons between datasets. A p <0.05 was considered statistically significant. Result The quality of the targets of the three plannings was comparable. The total lung dose in P-VMAT was significantly lower than that in JT IMRT and F-VMAT. Monitor unit (MU) of F-VMAT and P-VMAT was significantly lower than that of JT IMRT. ROC analysis showed that among JT IMRT, F-VMAT, and P-VMAT, PCTVi-L, and PCTVi-L/TLL had diagnostic power to predict the suitability of RT plans according to lung dose constraints of our department. For JT IMRT, the cutoff points of PCTVi-L and PCTVi-L/TLL were 16.6 and 0.59. For F-VMAT, the cutoff points of PCTVi-L and PCTVi-L/TLL were 16.75 and 0.62. For P-VMAT, the cutoff points of PCTVi-L and PCTVi-L/TLL were 15.15 and 0.59. After Mann–Whitney U-test analysis, it was found that among the three plannings, the group with lower PCTVi-L and PCTVi-L/TLL could significantly reduce the dose of total lung and heart (p <0.05). Conclusion PCTVi-L <16.6 and PCTVi-L/TLL <0.59 for JT IMRT, PCTVi-L <16.75 and PCTVi-L/TLL <0.62 for F-VMAT and PCTVi-L <15.15, and PCTVi-L/TLL <0.59 for P-VMAT can predict whether patients with T-shaped UMEC can meet the lung dose limits of our department.
Collapse
Affiliation(s)
- Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.,Institute of Modern Physics, Fudan University, Shanghai, China
| | - Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.,Institute of Modern Physics, Fudan University, Shanghai, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yanhua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Aihui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hengle Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Qing Kong
- Institute of Modern Physics, Fudan University, Shanghai, China
| | - Zhiyong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
10
|
Chen H, Huang Y, Wang H, Shao Y, Yue NJ, Gu H, Duan Y, Feng A, Xu Z. Dosimetric comparison and biological evaluation of fixed-jaw intensity-modulated radiation therapy for T-shaped esophageal cancer. Radiat Oncol 2021; 16:158. [PMID: 34412656 PMCID: PMC8375041 DOI: 10.1186/s13014-021-01882-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 08/11/2021] [Indexed: 12/24/2022] Open
Abstract
Background To evaluate the dosimetric and biological benefits of the fixed-jaw (FJ) intensity-modulated radiation therapy (IMRT) technique for patients with T-shaped esophageal cancer. Methods FJ IMRT plans were generated for thirty-five patients and compared with jaw tracking (JT) IMRT, static jaw (SJ) IMRT and JT volumetric modulated arc therapy (VMAT). Dosimetric parameters, tumor control probability (TCP) and normal tissue complication probability (NTCP), monitor units (MUs), delivery time and gamma passing rate, as a measure of dosimetric verification, were compared. The correlation between the length of PTV-C below the upper boundary of lung tissue (PTV-Cinferior) and dosimetric parameters and NTCP of the lung tissue were analyzed. Results The homogeneity and conformity of the target in the four plans were basically equivalent. When compared to the JT IMRT and SJ IMRT plans, FJ IMRT plan led to a statistically significant improvement in the NTCP and low-middle dosimetric parameters of the lung, and the improvement had a moderately positive correlation with the length of PTV-Cinferior, with a correlation coefficient ranging from 0.523 to 0.797; the FJ IMRT plan exhibited better lung sparing in low-dose volumes than the JT VMAT plan. The FJ IMRT plan had similar MUs (888 ± 99) and delivery times (516.1 ± 54.7 s) as the JT IMRT plan (937 ± 194, 522 ± 5.6 s) but higher than SJ IMRT (713 ± 137, 488.8 ± 45.2 s) and JT VMAT plan (517 ± 59, 263.7 ± 43.3 s). Conclusions The FJ IMRT technique is superior in reducing the low-dose volumes of lung tissues for patients with T-shaped esophageal cancer.
Collapse
Affiliation(s)
- Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Ning J Yue
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08903, USA
| | - Hengle Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Yanhua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Aihui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Zhiyong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China.
| |
Collapse
|
11
|
Xie M, Ding X, Chen A, Xiao H, Wang X, Wang Y, Zhang H. Efficacy and Safety of Image-Guided Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Combined with Paclitaxel Liposomes and Cisplatin for Locally Advanced Stage IIB-IIIB Cervical Cancer: A Retrospective Study at a Single Center. Med Sci Monit 2020; 26:e927563. [PMID: 33293504 PMCID: PMC7734881 DOI: 10.12659/msm.927563] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/12/2020] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND This retrospective study aimed to investigate the efficacy and safety of image-guided intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) combined with administration of paclitaxel liposomes and cisplatin for locally advanced stage IIB-IIIB cervical cancer at a single center in China. MATERIAL AND METHODS The clinical data of 126 patients with stage IIB-IIIB cervical cancer treated in our hospital were retrospectively analyzed. The patients were divided into the IMRT group (n=63) and the VMAT group (n=63). The short-term clinical efficacy, the incidence of adverse reactions, the quality-of-life score, and the changes in levels of T-lymphocyte subsets, serum inflammatory factors, and tumor markers were compared pre- and posttreatment between the 2 groups. RESULTS The clinical response rate was 90.5% and 96.8% in the IMRT group and the VMAT group, respectively; the difference was not statistically significant. After treatment, the levels of CD3⁺, CD4⁺, and CD4⁺/CD8⁺ subsets rose significantly, while the CD8⁺ level declined significantly in both groups compared with the pretreatment levels. After treatment, the levels of serum vascular endothelial growth factor, squamous cell carcinoma antigen, interleukin-8, tumor necrosis factor-a, carcinoembryonic antigen, and carbohydrate antigen 125 declined in both groups compared with pretreatment levels. After treatment, the Karnofsky performance scale score rose in both groups, and it was higher in the VMAT group than in the IMRT group. CONCLUSIONS IMRT and VMAT combined with paclitaxel liposomes and cisplatin have similar short-term clinical efficacy and long-term survival rates in the treatment of stage IIB-IIIB cervical cancer.
Collapse
|
12
|
The effect of photon energy on dose distribution in volumetric-modulated arc therapy planning for head and neck cancer. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396920000254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractAim:To investigate the effect of different energies on dose distribution in volumetric-modulated arc therapy (VMAT) plans for head and neck cancer.Materials and methods:Data from nine patients undergoing VMAT plans using 6 MV, 10 MV and dual-energy X-ray beams with the Pinnacle 3 V 9.10 treatment planning system (Philips Medical System, Fitchburg, WI, USA) were analysed for quality using the conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), and for mean and maximum dose to the organs at risk (OARs): parotid glands, brainstem, spinal cord and optic nerves.Results:There were no clear differences in the HIs of the PTV dose among the different plans. The CIs for 10 MV and dual-energy VMAT plans were superior to that of the 6 MV VMAT plan (0·8 ± 0·3, 0·8 ± 0·3, and 0·7 ± 0·2, respectively; p = 0·001). There were no significant differences in mean/maximum dose to the OARs among the three VMAT plans.Findings:Compared with the 6 MV VMAT plan, the dual-energy VMAT plan slightly increased the coverage of the PTV with the prescribed dose but did not decrease dose to the OARs.
Collapse
|
13
|
Song W, Lu H, Liu J, Zhao D, Ma J, Zhang B, Yu D, Sun X, Li J. Fixed-jaw technique to improve IMRT plan quality for the treatment of cervical and upper thoracic esophageal cancer. J Appl Clin Med Phys 2019; 20:24-32. [PMID: 31460704 PMCID: PMC6806698 DOI: 10.1002/acm2.12704] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 06/30/2019] [Accepted: 07/26/2019] [Indexed: 11/12/2022] Open
Abstract
The purpose of this study was to investigate the potential advantages of the fixed-jaw technique (FJT) over the conventional split-field technique (SFT) for cervical and upper thoracic esophageal cancer (EC) patients treated with intensity-modulated radiotherapy. The SFT and FJT plans were generated for 15 patients with cervical and upper thoracic EC. Dosimetric parameters and delivery efficiency were compared. An area ratio (AR) of the jaw opening to multileaf collimator (MLC) aperture weighted by the number of monitor units (MUs) was defined to evaluate the impact of the transmission through the MLC on the dose gradient outside the PTV50.4, and the correlation between the gradient index (GI) and AR was analyzed. The FJT plans achieved a better GI and AR (P < 0.001). There was a positive correlation between the GI and AR in the FJT (r = 0.883, P < 0.001) and SFT plans (r = 0.836, P < 0.001), respectively. Moreover, the mean dose (Dmean ), V5Gy -V40Gy for the lungs and the Dmean , V5Gy -V50Gy for the body-PTV50.4 in the FJT plans were lower than those in the SFT plans (P < 0.05). The FJT plans demonstrated a reduction trend in the doses to the spinal cord PRV and heart, but only the difference in the heart Dmean reached statistical significance (P < 0.05). The FJT plans reduced the number of MUs and subfields by 5.5% and 17.9% and slightly shortened the delivery time by 0.23 min (P < 0.05). The gamma-index passing rates were above 95% for both plans. The FJT combined with target splitting can provide superior organs at risk sparing and similar target coverage without compromising delivery efficiency and should be a preferred intensity-modulated radiotherapy planning method for cervical and upper thoracic EC patients.
Collapse
Affiliation(s)
- Wei Song
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Hong Lu
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Jie Liu
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Di Zhao
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Jun Ma
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Biyun Zhang
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Dahai Yu
- Department of Radiation Oncology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Xinchen Sun
- Department of Radiation Oncology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Jinkai Li
- Department of Radiation Oncology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| |
Collapse
|
14
|
Du XX, Yu R, Wang ZF, Du DC, Liu QY, Wang RM, Kang SR, Yang H. Outcomes and prognostic factors for patients with cervical esophageal cancer undergoing definitive radiotherapy or chemoradiotherapy. Bosn J Basic Med Sci 2019; 19:186-194. [PMID: 30877837 DOI: 10.17305/bjbms.2019.3873] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Accepted: 10/16/2018] [Indexed: 12/26/2022] Open
Abstract
Cervical esophageal cancer (CEC) is uncommon, accounting for less than 5% of all esophageal cancers. The management of CEC is controversial. This study investigated treatment outcomes and prognostic factors of survival in CEC patients undergoing definitive radiotherapy or concurrent chemoradiotherapy (CCRT). Ninety-one CEC patients were treated by intensity-modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3DCRT) between July 2007 and September 2017. The mean prescription dose was 64 Gy (range 54-70 Gy) delivered as 1.8-2.2 Gy per fraction per day, 5 days a week. Out of 91 patients, 34 received concurrent cisplatin-based chemotherapy (CT) including 18 patients who also received neoadjuvant CT. Overall survival (OS), locoregional failure-free survival (LRFFS), and progression-free survival (PFS) were estimated by the Kaplan-Meier method. Prognostic factors of survival were determined in univariate (log-rank test) and multivariate (Cox proportional hazard model) analysis. Treatment-related toxicity was also assessed. Median follow-up time for all patients was 19 months. Two-year OS, LRFFS and PFS of all patients were 58.2%, 52.5% and 48.1%, respectively. Clinical stage was an independent prognostic factor for OS (HR = 2.35, 95% CI: 1.03-5.37, p = 0.042), LRFFS (HR = 3.84, 95% CI: 1.38-10.69, p = 0.011), and PFS (HR = 2.68, 95% CI: 1.11-6.45, p = 0.028). Hoarseness was an independent prognostic factor for OS (HR = 2.10, 95% CI: 1.05-4.19, p = 0.036). CCRT was independently associated with better LRFFS (HR = 0.33, 95% CI: 0.14-0.79, p = 0.012). 3DCRT and IMRT with concurrent CT is well-tolerated and may improve local tumor control in CEC patients. Advanced clinical stage and hoarseness are adverse prognostic factors for OS, LRFFS, and PFS in CEC.
Collapse
Affiliation(s)
- Xin-Xin Du
- Department of Radiotherapy, Inner Mongolia Cancer Hospital, The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot; Department of Obstetrics and Gynecology, Chinese PLA General Hospital, Beijing, China; Research Group for Reproductive Medicine and IVF-Laboratory, Department of Obstetrics and Genecology, University of Cologne, Cologne, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Kim KH, Chung JB, Suh TS, Kang SW, Kang SH, Eom KY, Song C, Kim IA, Kim JS. Dosimetric and radiobiological comparison in different dose calculation grid sizes between Acuros XB and anisotropic analytical algorithm for prostate VMAT. PLoS One 2018; 13:e0207232. [PMID: 30419058 PMCID: PMC6231664 DOI: 10.1371/journal.pone.0207232] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 10/27/2018] [Indexed: 11/19/2022] Open
Abstract
To investigate feasible treatment planning parameters, we aimed to evaluate the dosimetric and radiobiological impact of the dose calculation algorithm and grid size in the volumetric modulated arc therapy (VMAT) plan for prostate cancer. Twenty patients were selected, and the treatment plans were initially generated with anisotropic analytical algorithm (AAA) and recalculated with Acuros XB (AXB) algorithm. Various dose grids were used for AXB (1, 2, and 3 mm) and AAA (1, 3, and 5 mm) plan. Dosimetric parameters such as homogeneity index (HI) and conformity index (CI), and radiobiological parameters such as tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated. Significant differences were observed in the planning target volume (PTV) coverage between both algorithms, and the V95%, HI, and CI of AAA were significantly affected by grid (p < 0.01). On 1 mm grid, the mean rectal dose difference between both algorithms was 2.87% of the prescription dose (p < 0.01), which was the highest among the critical organs. The TCP and NTCP of the AAA were higher than those of AXB (p < 0.01). Compared to AXB with 1 mm grid, the 2 mm grid showed comparable dose calculation accuracy with short calculation time. This study found that the PTV and rectum show significant differences according to dose calculation algorithm and grid. Considering the dose calculation performance for heterogeneous area, we recommend AXB with 2 mm grid for improving treatment efficiency of prostate VMAT.
Collapse
Affiliation(s)
- Kyeong-Hyeon Kim
- Department of Biomedicine & Health Sciences, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea, Seoul, Korea
| | - Jin-Beom Chung
- Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Korea
- * E-mail: (JBC); (TSS)
| | - Tae Suk Suh
- Department of Biomedicine & Health Sciences, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea, Seoul, Korea
- * E-mail: (JBC); (TSS)
| | - Sang-Won Kang
- Department of Biomedicine & Health Sciences, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea, Seoul, Korea
| | - Seong-Hee Kang
- Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Keun-Yong Eom
- Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Changhoon Song
- Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - In-Ah Kim
- Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Jae-Sung Kim
- Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Korea
| |
Collapse
|
16
|
Nachbar M, Mönnich D, Kalwa P, Zips D, Thorwarth D, Gani C. Comparison of treatment plans for a high-field MRI-linac and a conventional linac for esophageal cancer. Strahlenther Onkol 2018; 195:327-334. [PMID: 30361744 DOI: 10.1007/s00066-018-1386-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 10/09/2018] [Indexed: 01/06/2023]
Abstract
PURPOSE To compare radiotherapy treatments plans in esophageal cancer calculated for a high-field magnetic resonance imaging (MRI)-linac with plans for a conventional linac. MATERIALS AND METHODS Ten patients with esophageal squamous cell carcinomas were re-planned retrospectively using the research version of Monaco (V 5.19.03, Elekta AB, Stockholm, Sweden). Intensity modulated radiotherapy (IMRT) plans with a nine-field step-and-shoot technique and two-arc volumetric modulated arc therapy (VMAT) plans were created for the Elekta MRI-linac and a conventional linac, respectively. The prescribed dose was 60 Gy to the primary tumor (PTV60) and 50 Gy to elective volumes (PTV50). Plans were optimized for optimal coverage of the 60 Gy volume and compared using dose-volume histogram parameters. RESULTS All calculated treatment plans met predefined criteria for target volume coverage and organs at risk dose both for MRI-linac and conventional linac. Plans for the MRI-linac had a lower number of segments and monitor units. No significant differences between both plans were seen in terms of V20Gy of the lungs and V40Gy of the heart with slightly higher mean doses to the heart (14.0 Gy vs. 12.5 Gy) and lungs (12.8 Gy vs. 12.2 Gy). CONCLUSION Applying conventional target volume and margin concepts as well as dose-fractionation prescription reveals clinically acceptable dose distributions using hybrid MRI-linac in its current configuration compared to standard IMRT/VMAT. This represents an important prerequisite for future studies to investigate the clinical benefit of MRI-guided radiotherapy exploiting the conceptional advantages such as reduced margins, plan adaptation and biological individualization and hypofractionation.
Collapse
Affiliation(s)
- Marcel Nachbar
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - David Mönnich
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Paul Kalwa
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Daniel Zips
- German Cancer Consortium (DKTK), Partner Site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany
| | - Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
- German Cancer Consortium (DKTK), Partner Site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Cihan Gani
- German Cancer Consortium (DKTK), Partner Site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany.
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
- Gastrointestinal Cancer Center, Comprehensive Cancer Center Tübingen-Stuttgart, Tübingen, Germany.
| |
Collapse
|
17
|
Patel SA, Edgington SK, Adams J, Morse C, Ryan DP, Hong TS. Novel use of proton beam therapy for neoadjuvant treatment of radiation-associated squamous cell carcinoma of the esophagus. J Gastrointest Oncol 2018; 10:155-160. [PMID: 30788171 DOI: 10.21037/jgo.2018.09.06] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Secondary esophageal cancers from prior thoracic radiation therapy are rare but challenging cases to deliver standard combined modality therapy as part of a curative approach. In patients with prior exposure to cardiopulmonary-toxic chemotherapy or radiotherapy, management requires meticulous multidisciplinary evaluation given the morbidity associated with surgery in the previously irradiated thorax and re-irradiation of the spinal cord, heart, and lungs. Oftentimes, suboptimal treatment regimens, either with compromised radiation coverage, attenuated chemotherapy doses, or exclusion of surgery, are required to avoid significant toxicity. The physical properties inherent to protons allow for optimal coverage of tumor while achieving remarkably low dose to surrounding normal tissue compared to standard photon treatment. Proton therapy has been studied across various disease sites and may facilitate treatment intensification for radiation-associated esophageal tumors. While no comparative studies have evaluated the efficacy and safety of protons versus photons for esophageal cancer, three cases of radiation-associated esophageal cancer presented in this series are exemplary to highlight the benefit of protons in this unique clinical circumstance. The technical considerations in planning, including passively scattered versus pencil-beam scanning technique, as well as the clinical course and tolerance to treatment, are discussed, which may guide consideration of this advanced treatment modality in this disease site.
Collapse
Affiliation(s)
- Sagar A Patel
- Department of Radiation Oncology, Emory University, Atlanta, GA, USA.,Harvard Radiation Oncology Program, Harvard Medical School, Boston, MA, USA
| | - Samantha K Edgington
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| | - Judith Adams
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| | - Christopher Morse
- Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - David P Ryan
- Department of Medicine, Massachusetts General Hospital, Boston, MA, USA
| | - Theodore S Hong
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
18
|
Deng W, Lin SH. Advances in radiotherapy for esophageal cancer. ANNALS OF TRANSLATIONAL MEDICINE 2018; 6:79. [PMID: 29666802 DOI: 10.21037/atm.2017.11.28] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Esophageal cancer is a common type of malignancy worldwide and usually requires multidisciplinary care. Radiotherapy plays an important part in management of the disease. During the past few years, researchers have made much progress about radiotherapy for esophageal cancer, which was revealed in every aspect of clinical practice. Neoadjuvant chemoradiotherapy remains the standard treatment for locally advanced esophageal cancer, whereas neoadjuvant chemotherapy appears to show less toxicities and non-inferior prognosis. What's more, definitive chemoradiotherapy could be an option for non-surgical candidates and good responders to chemoradiotherapy. Advances in radiation techniques result in higher conformity, homogeneity, more normal tissue sparing and less treatment time. Promising prognoses and less toxicities were also seen in advanced techniques. As radiation dose higher than 50 Gy obtains better local control and survival, simultaneously integrated boost is designed to increase primary tumor dosage and keep prophylactic dose to subclinical areas. Elective nodal irradiation brings about better local control but do not show advantages in survival compared with involved field irradiation (IFI). As a trend, more tolerable chemoradiotherapy regimen would be taken into account in dealing with elderly patients.
Collapse
Affiliation(s)
- Wei Deng
- Department of Radiation Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
| | - Steven H Lin
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
19
|
Haefner MF, Lang K, Verma V, Koerber SA, Uhlmann L, Debus J, Sterzing F. Intensity-modulated versus 3-dimensional conformal radiotherapy in the definitive treatment of esophageal cancer: comparison of outcomes and acute toxicity. Radiat Oncol 2017; 12:131. [PMID: 28810885 PMCID: PMC5558777 DOI: 10.1186/s13014-017-0863-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Accepted: 08/04/2017] [Indexed: 12/20/2022] Open
Abstract
Background Though the vast majority of seminal trials for locally advanced esophageal cancer (EC) utilized three-dimensional conformal radiotherapy (3DCRT), the advanced and highly conformal technology known as intensity-modulated radiotherapy (IMRT) can decrease doses to critical cardiopulmonary organs. To date, there have been no studies comparing both modalities as part of definitive chemoradiation (dCRT) for EC. Herein, we investigated local control and survival and evaluated clinical factors associated with these endpoints between cohorts. Methods We retrospectively analyzed 93 patients (3DCRT n = 49, IMRT n = 44) who received dCRT at our institution between 2000 and 2012 with the histologic diagnosis of nonmetastatic EC, a Karnofsky performance status of ≥70, curative treatment intent, and receipt of concomitant CRT. Patients were excluded if receiving <50 Gy. Kaplan-Meier analysis was used to evaluate the endpoints of local relapse rate (LR), progression-free survival (PFS), and overall survival (OS). Cox proportional hazards modeling addressed factors associated with outcomes with univariate and multivariate approaches. Rates of acute toxicities and basic dosimetric parameters were compared between 3DCRT and IMRT patients. Results Mean follow-up was 34.7 months. The 3-year LR was 28.6% in the 3DCRT group and 22.7% in the IMRT group (p = 0.620). Median PFS were 13.8 and 16.6 months, respectively (p = 0.448). Median OS were 18.4 and 42.0 months, respectively (p = 0.198). On univariate analysis, only cumulative radiation dose was associated with superior LR (hazard ratio (HR) 0.736; 95% confidence interval (CI) 0.635 – 0.916, p = 0.004). Factors clearly affecting survival were not observed. Conclusions When comparing 3DCRT- versus IMRT-based dCRT, no survival benefits were observed. However, we found a lower local recurrence rate in the IMRT group potentially owing to dose-escalation. Prospective data are needed to verify the presented results herein.
Collapse
Affiliation(s)
- Matthias Felix Haefner
- Department of Radiation Oncology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. .,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Kristin Lang
- Department of Radiation Oncology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Vivek Verma
- Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Stefan Alexander Koerber
- Department of Radiation Oncology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Lorenz Uhlmann
- Institute of Medical Biometry and Informatics (IMBI), University of Heidelberg, Im Neuenheimer Feld 130.3, 69120, Heidelberg, Germany
| | - Juergen Debus
- Department of Radiation Oncology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Florian Sterzing
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Department of Radiation Oncology, Hospital Kempten, Robert-Weixler-Strasse 50, 87439, Kempten, Germany
| |
Collapse
|
20
|
Xi M, Lin SH. Recent advances in intensity modulated radiotherapy and proton therapy for esophageal cancer. Expert Rev Anticancer Ther 2017; 17:635-646. [PMID: 28503964 DOI: 10.1080/14737140.2017.1331130] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Radiotherapy is an important component of the standard of care for esophageal cancer. In the past decades, significant improvements in the planning and delivery of radiation techniques have led to better dose conformity to the target volume and improved normal tissue sparing. Areas covered: This review focuses on the advances in radiotherapy techniques and summarizes the availably dosimetric and clinical outcomes of intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, proton therapy, and four-dimensional radiotherapy for esophageal cancer, and discusses the challenges and future development of proton therapy. Expert commentary: Although three-dimensional conformal radiotherapy is the standard radiotherapy technique in esophageal cancer, the retrospectively comparative studies strongly suggest that the dosimetric advantage of IMRT over three-dimensional conformal radiotherapy can translate into improved clinical outcomes, despite the lack of prospective randomized evidence. As a novel form of conventional IMRT technique, volumetric modulated arc therapy can produce equivalent or superior dosimetric quality with significantly higher treatment efficiency in esophageal cancer. Compared with photon therapy, proton therapy has the potential to achieve further clinical improvement due to their physical properties; however, prospective clinical data, long-term results, and cost-effectiveness are needed.
Collapse
Affiliation(s)
- Mian Xi
- a Department of Radiation Oncology, Cancer Center , Sun Yat-Sen University, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine , Guangzhou , Guangdong , China
| | - Steven H Lin
- b Department of Radiation Oncology , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| |
Collapse
|
21
|
Yang H, Feng C, Cai BN, Yang J, Liu HX, Ma L. Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma. Dis Esophagus 2017; 30:1-8. [PMID: 27629865 DOI: 10.1111/dote.12497] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The aim of this study was to evaluate the effectiveness and toxicities of three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) in patients with cervical esophageal cancer. Specifically, we asked whether technological advances conferred an advantage with respect to the clinical curative effect. Seventy-eight patients with cervical esophageal cancer treated with definitive radiotherapy with or without concomitant chemotherapy at our institution between 2007 and 2014 were enrolled in the study: 26 received 3DCRT, 30 were treated with IMRT, and 22 underwent VMAT. Kaplan-Meier analysis and the Cox proportional hazard model were used to analyze overall survival (OS) and failure-free survival (FFS). Treatment-related toxicity was also assessed. For all patients, the 2-year OS and FFS rates were 56.2 and 53.9%, respectively. The 2-year OS for the 3DCRT, IMRT, and VMAT groups was 53.6, 55.6, and 60.6%, respectively (P = 0.965). The corresponding 2-year FFS rates were 49.5, 56.7, and 60.1% (P = 0.998). A univariate analysis of the complete response to treatment showed an advantage of treatment modality with respect to OS (P < 0.001). The development of acute hematologic toxicity was not significantly different among the three groups. The survival rates of patients treated with IMRT and VMAT were comparable to the survival of patients administered 3DCRT, while lower lung mean dose, V20, maximum dose of brachial plexus and spinal cord. Grade 1 radiation pneumonitis occurred significantly less in patients treated with IMRT and VMAT than with 3DCRT (P = 0.011). A complete response was the most important prognostic factor of the patients with cervical esophageal cancer.
Collapse
Affiliation(s)
- Hao Yang
- Department of Radiation Oncology, Inner Mongolia Cancer Hospital and The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.,Department of Radiation Oncology, Inner Mongolia Cancer Hospital and The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Cong Feng
- Emergency Medicine , Chinese PLA General Hospital, Beijing, China
| | - Bo-Ning Cai
- Department of Radiation Oncology, Inner Mongolia Cancer Hospital and The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Jun Yang
- Department of Radiation Oncology, Inner Mongolia Cancer Hospital and The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Hai-Xia Liu
- Department of Radiation Oncology, Inner Mongolia Cancer Hospital and The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Lin Ma
- Department of Radiation Oncology, Inner Mongolia Cancer Hospital and The Affiliated People's Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| |
Collapse
|
22
|
Comparison of dosimetric parameters and toxicity in esophageal cancer patients undergoing 3D conformal radiotherapy or VMAT. Strahlenther Onkol 2016; 192:722-9. [PMID: 27418129 DOI: 10.1007/s00066-016-1020-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 06/24/2016] [Indexed: 12/25/2022]
Abstract
PURPOSE Volumetric-modulated arc therapy (VMAT) achieves high conformity to the planned target volume (PTV) and good sparing of organs at risk (OAR). This study compares dosimetric parameters and toxicity in esophageal cancer (EC) patients treated with VMAT and 3D conformal radiotherapy (3D-CRT). MATERIALS AND METHODS Between 2007 and 2014, 17 SC patients received neoadjuvant chemoradiation (CRT) with VMAT. Dose-volume histograms and toxicity were compared between these patients and 20 treated with 3D-CRT. All patients were irradiated with a total dose of 45 Gy. All VMAT patients received simultaneous chemotherapy with cisplatin and 5‑fluorouracil (5-FU) in treatment weeks 1 and 5. Of 20 patients treated with 3D-CRT, 13 (65 %) also received CRT with cisplatin and 5‑FU, whereas 6 patients (30 %) received CRT with weekly oxaliplatin and cetuximab, and a continuous infusion of 5‑FU (OE-7). RESULTS There were no differences in baseline characteristics between the treatment groups. For the lungs, VMAT was associated with a higher V5 (median 90.1 % vs. 79.7 %; p = 0.013) and V10 (68.2 % vs. 56.6 %; p = 0.014), but with a lower V30 (median 6.6 % vs. 11.0 %; p = 0.030). Regarding heart parameters, VMAT was associated with a higher V5 (median 100.0 % vs. 91.0 %; p = 0.043), V10 (92.0 % vs. 79.2 %; p = 0.047), and Dmax (47.5 Gy vs. 46.3 Gy; p = 0.003), but with a lower median dose (18.7 Gy vs. 30.0 Gy; p = 0.026) and V30 (17.7 % vs. 50.4 %; p = 0.015). Complete resection was achieved in 16 VMAT and 19 3D-CRT patients. Due to systemic progression, 2 patients did not undergo surgery. The most frequent postoperative complication was anastomosis insufficiency, occurring in 1 VMAT (6.7 %) and 5 3D-CRT patients (27.8 %; p = 0.180). Postoperative pneumonia was seen in 2 patients of each group (p = 1.000). There was no significant difference in 3‑year overall (65 % VMAT vs. 45 % 3D-CRT; p = 0.493) or 3‑year progression-free survival (53 % VMAT vs. 35 % 3D-CRT; p = 0.453). CONCLUSION Although dosimetric differences in lung and heart exposure were observed, no clinically relevant impact was detected in either patient group. In a real-life patient cohort, VMAT enables reduction of lung and heart V30 compared to 3D-CRT, which may contribute to reduced toxicity.
Collapse
|