1
|
Amambo GN, Innocentia N, Abong RA, Fombad FF, Njouendou AJ, Nietcho F, Ekanya R, Kien CA, Ebai R, Lenz B, Ritter M, Esum ME, Deribe K, Cho JF, Beng AA, Enyong PI, Li Z, Hübner MP, Pfarr K, Hoerauf A, Carlow C, Wanji S. Application of loop mediated isothermal amplification (LAMP) assays for the detection of Onchocerca volvulus, Loa loa and Mansonella perstans in humans and vectors. FRONTIERS IN TROPICAL DISEASES 2023; 3:1016176. [PMID: 36684508 PMCID: PMC7614089 DOI: 10.3389/fitd.2022.1016176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Conventional diagnosis of filarial infections is based on morphological identification of microfilariae using light microscopy and requires considerable expertise, is time-consuming, and can be subjective. Loop-mediated isothermal amplification (LAMP) has advantages over microscopy or PCR because of its operational simplicity, rapidity and versatility of readout options. LAMP assays represent a major step forward in improved filarial diagnostic tools suitable for low resource settings and field applicability. The study goal was to retrospectively evaluate the performance and suitability of the O-150, RF4, and Mp419 LAMP assays for diagnosing Onchocerca volvulus, Loa loa and Mansonella perstans infections, respectively, in humans and vectors under experimental and natural field conditions. Surveys were conducted in four health districts of Cameroon using skin snip and thick blood film methods to detect skin (O. volvulus) and blood (L. loa and M. perstans) dwelling microfilaria in humans. Engorged vectors (Simulium spp., Chrysops spp., and Culicoides spp.) were evaluated by LAMP. Dissected, wild-caught vectors were also analyzed. LAMP showed a prevalence of 40.4% (O. volvulus), 17.8% (L. loa) and 36.6% (M. perstans) versus 20.6% (O. volvulus), 17.4% (L. loa) and 33.8% (M. perstans) with microscopy. Simulium spp. were dissected for microscopy and pooled for LAMP. The O-150 LAMP assay infection rate was 4.3% versus 4.1% by microscopy. Chrysops spp. were dissected and analyzed individually in the LAMP assay. The RF4 LAMP assay infection rate was 23.5% versus 3.3% with microscopy. The RF4 LAMP assay also detected parasites in Chrysops spp. fed on low microfilaremic volunteers. The Mp419 LAMP assay infection rate was 0.2% for C. milnei and 0.04% for C. grahamii, while three other species were LAMP-negative. The sensitivity, species specificity, rapidity and ease of its use of these filarial LAMP assays, and validation of their performance in the field support use as alternatives to microscopy as diagnostic and surveillance tools in global health programs aimed to eliminate onchocerciasis.
Collapse
Affiliation(s)
- Glory Ngongeh Amambo
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Ngong Innocentia
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Raphael Awah Abong
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Fanny Fri Fombad
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Abdel Jelil Njouendou
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Department of Biomedical Science, Faculty of Health Sciences, University of Buea, Buea, Cameroon
| | - Franck Nietcho
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
| | - Relindis Ekanya
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Chi Anizette Kien
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Rene Ebai
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Benjamin Lenz
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
| | - Manuel Ritter
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
| | - Mathias Eyong Esum
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Kebede Deribe
- Global Health and Infection Department, Brighton and Sussex Medical School, Brighton, United Kingdom
- School of Public Health, Addis Ababa University, Addis Ababa, Ethiopia
| | - Jerome Fru Cho
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Amuam Andrew Beng
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Peter Ivo Enyong
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| | - Zhiru Li
- New England Biolabs, Ipswich, MA, United States
| | - Marc P. Hübner
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
- German Center for Infection Research (DZIF), Partner Site Bonn-Cologne, Bonn, Germany
| | - Kenneth Pfarr
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
- German Center for Infection Research (DZIF), Partner Site Bonn-Cologne, Bonn, Germany
| | - Achim Hoerauf
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
- German Center for Infection Research (DZIF), Partner Site Bonn-Cologne, Bonn, Germany
- German-West African Centre for Global Health and Pandemic Prevention (G-WAC), Partner Site Bonn, Bonn, Germany
| | | | - Samuel Wanji
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), Buea, Cameroon
| |
Collapse
|
2
|
Li Z, Bruce JL, Cohen B, Cunningham CV, Jack WE, Kunin K, Langhorst BW, Miller J, Moncion RA, Poole CB, Premsrirut PK, Ren G, Roberts RJ, Tanner NA, Zhang Y, Carlow CKS. Development and implementation of a simple and rapid extraction-free saliva SARS-CoV-2 RT-LAMP workflow for workplace surveillance. PLoS One 2022; 17:e0268692. [PMID: 35617204 PMCID: PMC9135294 DOI: 10.1371/journal.pone.0268692] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 05/04/2022] [Indexed: 01/12/2023] Open
Abstract
Effective management of the COVID-19 pandemic requires widespread and frequent testing of the population for SARS-CoV-2 infection. Saliva has emerged as an attractive alternative to nasopharyngeal samples for surveillance testing as it does not require specialized personnel or materials for its collection and can be easily provided by the patient. We have developed a simple, fast, and sensitive saliva-based testing workflow that requires minimal sample treatment and equipment. After sample inactivation, RNA is quickly released and stabilized in an optimized buffer, followed by reverse transcription loop-mediated isothermal amplification (RT-LAMP) and detection of positive samples using a colorimetric and/or fluorescent readout. The workflow was optimized using 1,670 negative samples collected from 172 different individuals over the course of 6 months. Each sample was spiked with 50 copies/μL of inactivated SARS-CoV-2 virus to monitor the efficiency of viral detection. Using pre-defined clinical samples, the test was determined to be 100% specific and 97% sensitive, with a limit of detection of 39 copies/mL. The method was successfully implemented in a CLIA laboratory setting for workplace surveillance and reporting. From April 2021-February 2022, more than 30,000 self-collected samples from 755 individuals were tested and 85 employees tested positive mainly during December and January, consistent with high infection rates in Massachusetts and nationwide.
Collapse
Affiliation(s)
- Zhiru Li
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | | | - Barry Cohen
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | | | - William E. Jack
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | - Katell Kunin
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | | | - Jacob Miller
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | - Reynes A. Moncion
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | | | | | - Guoping Ren
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | | | - Nathan A. Tanner
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | - Yinhua Zhang
- New England Biolabs, Ipswich, Massachusetts, United States of America
| | | |
Collapse
|
3
|
Colorimetric and Real-Time Loop-Mediated Isothermal Amplification (LAMP) for Detection of Loa loa DNA in Human Blood Samples. Diagnostics (Basel) 2022; 12:diagnostics12051079. [PMID: 35626235 PMCID: PMC9139441 DOI: 10.3390/diagnostics12051079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/22/2022] [Accepted: 04/23/2022] [Indexed: 02/04/2023] Open
Abstract
Loiasis, caused by the filarial nematode Loa loa, is endemic in Central and West Africa. Loa loa has been associated with severe adverse reactions in high Loa-infected individuals receiving ivermectin during mass drug administration programs for the control of onchocerciasis and lymphatic filariasis. Diagnosis of loiasis still depends on microscopy in blood samples, but this is not effective for large-scale surveys. New diagnostics methods for loiasis are urgently needed. Previously, we developed a colorimetric high-sensitive and species-specific LAMP for Loa loa DNA detection. Here, we evaluate it in a set of 100 field-collected clinical samples stored as dried blood spots. In addition, Loa loa-LAMP was also evaluated in real-time testing and compared with microscopy and a specific PCR/nested PCR. A simple saponin/Chelex-based method was used to extract DNA. Colorimetric and real-time LAMP assays detected more samples with microscopy-confirmed Loa loa and Loa loa/Mansonella perstans mixed infections than PCR/nested-PCR. Samples with the highest Loa loa microfilariae counts were amplified faster in real-time LAMP assays. Our Loa loa-LAMP could be a promising molecular tool for the easy, rapid and accurate screening of patients for loiasis in endemic areas with low-resource settings. The real-time testing (feasible in a handheld device) could be very useful to rule out high-microfilariae loads in infected patients.
Collapse
|
4
|
Maddison MD, Li Z, Miley KM, Poole CB, Carlow CKS, Unnasch TR. Development and Validation of a Colorimetric Reverse Transcriptase Loop-Mediated Isothermal Amplification Assay for Detection of Eastern Equine Encephalitis Virus in Mosquitoes. JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION 2022; 38:7-18. [PMID: 35276729 DOI: 10.2987/21-7047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Eastern equine encephalitis virus (EEEV) is a highly pathogenic alphavirus that causes periodic outbreaks in the eastern USA. Mosquito abatement programs are faced with various challenges with surveillance and control of EEEV and other mosquito-borne illnesses. Environmental sampling of mosquito populations can be technically complex. Here we report the identification of biomarkers, development and validation of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the detection of EEEV. Positive samples are easily visualized by a color change from pink to yellow. The assay was validated using EEEV from viral culture, experimentally spiked mosquito pools, and previously tested mosquito pools. The RT-LAMP assay detected viral titers down to approximately 10% of what would be present in a single infectious mosquito, based upon EEEV viral titers determined by previous competency studies. The RT-LAMP assay efficiently detected EEEV in combined aliquots from previously homogenized pools of mosquitoes, allowing up to 250 individual mosquitoes to be tested in a single reaction. No false positive results were obtained from RNA prepared from negative mosquito pools acquired from known and potential EEEV vectors. The colorimetric RT-LAMP assay is highly accurate, technically simple, and does not require sophisticated equipment, making it a cost-effective alternative to real time reverse transcriptase-polymerase chain reaction (RT-PCR) for vector surveillance.
Collapse
|
5
|
Amambo GN, Abong RA, Fombad FF, Njouendou AJ, Nietcho F, Beng AA, Manuel R, Esum ME, Deribe K, Cho JF, Enyong PI, Poole C, Hoerauf A, Carlow C, Wanji S. Validation of loop-mediated isothermal amplification for the detection of Loa loa infection in Chrysops spp in experimental and natural field conditions. Parasit Vectors 2021; 14:19. [PMID: 33407819 PMCID: PMC7788981 DOI: 10.1186/s13071-020-04506-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 11/30/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The mass drug administration of ivermectin for onchocerciasis control has contributed to a significant drop in Loa loa microfilaria loads in humans that has, in turn, led to reduction of infection levels in Chrysops vectors. Accurate parasite detection is essential for assessing loiasis transmission as it provides a potential alternative or indirect strategy for addressing the problem of co-endemic loiasis and lymphatic filariasis through the Onchocerciasis Elimination Programme and it further reflects the true magnitude of the loiasis problem as excess human mortality has been reported to be associated with the disease. Although microscopy is the gold standard for detecting the infection, the sensitivity of this method is compromised when the intensity of infection is low. The loop-mediated isothermal amplification (LAMP) assay of parasite DNA is an alternative method for detecting infection which offers operational simplicity, rapidity and versatility of visual readout options. The aim of this study was to validate the Loa loa LAMP assay for the detection of infected Chrysops spp. under experimental and natural field conditions. METHODS Two sets of 18 flies were fed on volunteers with either a low (< 10 mf/ml) or high (> 30,000mf/ml) microfilarial load. The fed flies were maintained under laboratory conditions for 14 days and then analysed using LAMP for the detection of L. loa infection. In addition, a total of 9270 flies were collected from the north-west, east, and south-west regions (SW 1 and 2) of Cameroon using sweep nets and subjected to microscopy (7841 flies) and LAMP (1291 flies plus 138 nulliparous flies) analyses. RESULTS The LAMP assay successfully detected parasites in Chrysops fed on volunteers with both low and high microfilariaemic loads. Field validation and surveillance studies revealed LAMP-based infection rates ranging from 0.5 to 31.6%, with the lowest levels in SW 2 and the highest infection rates in SW 1. The LAMP assay detected significantly higher infection rates than microscopy in four of the five study sites. CONCLUSION This study demonstrated the potential of LAMP as a simple surveillance tool. It was found to be more sensitive than microscopy for the detection of experimental and natural L. loa infections in Chrysops vectors.
Collapse
Affiliation(s)
- Glory Ngongeh Amambo
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | - Raphael Awah Abong
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | - Fanny Fri Fombad
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | - Abdel Jelil Njouendou
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Department of Biomedical science, Faculty of Health Sciences, University of Buea, P.O. Box 63, Buea, Cameroon
| | - Franck Nietcho
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
| | - Amuam Andrew Beng
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | - Ritter Manuel
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
| | - Mathias Eyong Esum
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | - Kebede Deribe
- Global Health and Infection Department, Brighton and Sussex Medical School, Brighton, BN1 9PX, UK
- School of Public Health, Addis Ababa University, Addis Ababa, Ethiopia
| | - Jerome Fru Cho
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | - Peter Ivo Enyong
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon
| | | | - Achim Hoerauf
- Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany
- German Center for Infection Research (DZIF), Partner Site Bonn-Cologne, Bonn, Germany
| | | | - Samuel Wanji
- Parasites and Vector Research Unit (PAVRU), Department of Microbiology and Parasitology, University of Buea, P.O. Box 63, Buea, Cameroon.
- Research Foundation in Tropical Diseases and Environment (REFOTDE), P.O. Box 474, Buea, Cameroon.
| |
Collapse
|
6
|
A Simple and Multiplex Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid Detection of SARS-CoV. BIOCHIP JOURNAL 2019; 13:341-351. [PMID: 32226589 PMCID: PMC7097549 DOI: 10.1007/s13206-019-3404-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Accepted: 08/23/2019] [Indexed: 12/29/2022]
Abstract
The current diagnosis of severe acute respiratory syndrome-associated coronavirus (SARS-CoV) relies on laboratory-based tests since its clinical features are nonspecific, unlike other respiratory pathogens. Therefore, the development of a rapid and simple method for on-site detection of SARS-CoV is crucial for the identification and prevention of future SARS outbreaks. In this study, a simple colorimetric and multiplex loop-mediated isothermal amplification (LAMP) assay was developed to rapid screening of severe acute respiratory syndrome-associated coronavirus (SARS-CoV). It can be visually detected based on color change and monitored in real-time with fluorescent signals. The performance of this assay, based on six primers targeting open reading frame (ORF1b) and nucleocapsid (N) genes located in different regions of the SARS-CoV, was compared with real-time RT-PCR assay using various concentrations of target genes. The detection limit of the LAMP assay was comparable to that of real-time RT-PCR assay and therefore a few target RNA to 104-105 copies could be detected within a short period of time (20–25 min). In addition, we established a multiplex real-time LAMP assay to simultaneously detect two target regions within the SARS-CoV genome. Two target sequences were amplified by specific primers in the same reaction tube and revealed that it was able to detect down to 105 copies. The standard curve had a linear relationship with similar amplification efficiencies. The LAMP assay results in shorter “sample-to-answer” time than conventional PCR method. Therefore, it is suitable not only for diagnosis of clinical test, but also for surveillance of SARS virus in developing countries.
Collapse
|
7
|
In Silico Identification of Novel Biomarkers and Development of New Rapid Diagnostic Tests for the Filarial Parasites Mansonella perstans and Mansonella ozzardi. Sci Rep 2019; 9:10275. [PMID: 31311985 PMCID: PMC6635353 DOI: 10.1038/s41598-019-46550-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 06/29/2019] [Indexed: 02/02/2023] Open
Abstract
Mansonelliasis is a widespread yet neglected tropical infection of humans in Africa and South America caused by the filarial nematodes, Mansonella perstans, M. ozzardi, M. rodhaini and M. streptocerca. Clinical symptoms are non-distinct and diagnosis mainly relies on the detection of microfilariae in skin or blood. Species-specific DNA repeat sequences have been used as highly sensitive biomarkers for filarial nematodes. We have developed a bioinformatic pipeline to mine Illumina reads obtained from sequencing M. perstans and M. ozzardi genomic DNA for new repeat biomarker candidates which were used to develop loop-mediated isothermal amplification (LAMP) diagnostic tests. The M. perstans assay based on the Mp419 repeat has a limit of detection of 0.1 pg, equivalent of 1/1000th of a microfilaria, while the M. ozzardi assay based on the Mo2 repeat can detect as little as 0.01 pg. Both LAMP tests possess remarkable species-specificity as they did not amplify non-target DNAs from closely related filarial species, human or vectors. We show that both assays perform successfully on infected human samples. Additionally, we demonstrate the suitability of Mp419 to detect M. perstans infection in Culicoides midges. These new tools are field deployable and suitable for the surveillance of these understudied filarial infections.
Collapse
|
8
|
Deng MH, Zhong LY, Kamolnetr O, Limpanont Y, Lv ZY. Detection of helminths by loop-mediated isothermal amplification assay: a review of updated technology and future outlook. Infect Dis Poverty 2019; 8:20. [PMID: 30905322 PMCID: PMC6432754 DOI: 10.1186/s40249-019-0530-z] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Accepted: 03/07/2019] [Indexed: 02/06/2023] Open
Abstract
Background Helminths are endemic in more than half of the world’s countries, raising serious public health concerns. Accurate diagnosis of helminth infection is crucial to control strategies. Traditional parasitological methods, serological tests and PCR-based assays are the major means of the diagnosis of helminth infection, but they are time-consuming and/or expensive, and sometimes provide inaccurate results. Loop mediated isothermal amplification (LAMP) assay, a sensitive, simple and rapid method was therefore developed for detection of helminths. This study aims to discuss the current status of application of LAMP on helminths detection and to make a comprehensive evaluation about this updated technology and its future outlook by comparing with several other diagnostic methods. Main body This review summarizes LAMP assay applied for helminth detection and helminthiasis surveillance. The basic principle of LAMP is introduced to help better understand its characteristics and each reported assay is assessed mainly based on its detection sensitivity, specificity and limitations, in comparison with other common diagnostic tests. Moreover, we discuss the limitations of the assays so as to clarify some potential ways of improvement. Conclusions Here, we summarize and discuss the advantages, disadvantages and promising future of LAMP in heliminth detection, which is expected to help update current knowledge and future perspectives of LAMP in highly sensitive and specific diagnosis and surveillance of helminthiasis and other parasitic diseases, and can contribute to the elimination of the diseases from endemic areas. Electronic supplementary material The online version of this article (10.1186/s40249-019-0530-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Miao-Han Deng
- Zhongshan School of Medicine, Sun Yat-sen University, Guangzhou, 510080, China.,Key Laboratory of Tropical Disease Control (Sun Yat-sen University), Ministry of Education, Guangzhou, 510080, China
| | - Lan-Yi Zhong
- Zhongshan School of Medicine, Sun Yat-sen University, Guangzhou, 510080, China.,Key Laboratory of Tropical Disease Control (Sun Yat-sen University), Ministry of Education, Guangzhou, 510080, China
| | - Okanurak Kamolnetr
- Faculty of Tropical Medicine, Mahidol University, Bangkok, 10400, Thailand
| | - Yanin Limpanont
- Faculty of Tropical Medicine, Mahidol University, Bangkok, 10400, Thailand.
| | - Zhi-Yue Lv
- Zhongshan School of Medicine, Sun Yat-sen University, Guangzhou, 510080, China. .,Key Laboratory of Tropical Disease Control (Sun Yat-sen University), Ministry of Education, Guangzhou, 510080, China. .,Provincial Engineering Technology Research Center for Biological Vector Control, Guangzhou, 510080, China. .,Fifth Affiliated Hospital, Sun Yat-sen University, Guangzhou, 519000, China.
| |
Collapse
|
9
|
Rolando JC, Jue E, Schoepp NG, Ismagilov RF. Real-Time, Digital LAMP with Commercial Microfluidic Chips Reveals the Interplay of Efficiency, Speed, and Background Amplification as a Function of Reaction Temperature and Time. Anal Chem 2018; 91:1034-1042. [PMID: 30565936 PMCID: PMC6322147 DOI: 10.1021/acs.analchem.8b04324] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
![]()
Real-time,
isothermal, digital nucleic acid amplification is emerging
as an attractive approach for a multitude of applications including
diagnostics, mechanistic studies, and assay optimization. Unfortunately,
there is no commercially available and affordable real-time, digital
instrument validated for isothermal amplification; thus, most researchers
have not been able to apply digital, real-time approaches to isothermal
amplification. Here, we generate an approach to real-time digital
loop-mediated isothermal amplification (LAMP) using commercially available
microfluidic chips and reagents and open-source components. We demonstrate
this approach by testing variables that influence LAMP reaction speed
and the probability of detection. By analyzing the interplay of amplification
efficiency, background, and speed of amplification, this real-time
digital method enabled us to test enzymatic performance over a range
of temperatures, generating high-precision kinetic and end-point measurements.
We were able to identify the unique optimal temperature for two polymerase
enzymes while accounting for amplification efficiency, nonspecific
background, and time to threshold. We validated this digital LAMP
assay and pipeline by performing a phenotypic antibiotic susceptibility
test on 17 archived clinical urine samples from patients diagnosed
with urinary tract infections. We provide all the necessary workflows
to perform digital LAMP using standard laboratory equipment and commercially
available materials. This real-time digital approach will be useful
to others in the future to understand the fundamentals of isothermal
chemistries, including which components determine amplification fate,
reaction speed, and enzymatic performance. Researchers can also adapt
this pipeline, which uses only standard equipment and commercial components,
to quickly study and optimize assays using precise, real-time digital
quantification, accelerating development of critically needed diagnostics.
Collapse
Affiliation(s)
- Justin C Rolando
- Division of Chemistry & Chemical Engineering , California Institute of Technology , 1200 East California Boulevard , Mail Code 210-41, Pasadena , California , 91125 , United States
| | - Erik Jue
- Division of Biology & Biological Engineering , California Institute of Technology , 1200 East California Boulevard , Mail Code 210-41, Pasadena , California 91125 United States
| | - Nathan G Schoepp
- Division of Chemistry & Chemical Engineering , California Institute of Technology , 1200 East California Boulevard , Mail Code 210-41, Pasadena , California , 91125 , United States
| | - Rustem F Ismagilov
- Division of Chemistry & Chemical Engineering , California Institute of Technology , 1200 East California Boulevard , Mail Code 210-41, Pasadena , California , 91125 , United States.,Division of Biology & Biological Engineering , California Institute of Technology , 1200 East California Boulevard , Mail Code 210-41, Pasadena , California 91125 United States
| |
Collapse
|
10
|
Wong YP, Othman S, Lau YL, Radu S, Chee HY. Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms. J Appl Microbiol 2018; 124:626-643. [PMID: 29165905 PMCID: PMC7167136 DOI: 10.1111/jam.13647] [Citation(s) in RCA: 337] [Impact Index Per Article: 56.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 11/09/2017] [Accepted: 11/13/2017] [Indexed: 12/11/2022]
Abstract
Loop‐mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. (2000Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro‐organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro‐organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real‐time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro‐organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
Collapse
Affiliation(s)
- Y-P Wong
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| | - S Othman
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| | - Y-L Lau
- Department of Parasitology, Faculty of Medicine, Tropical Infectious Diseases Research and Education Centre (TIDREC), University of Malaya, Kuala Lumpur, Malaysia
| | - S Radu
- Centre of Excellence for Food Safety Research (FOSREC), Faculty of Food Science and Technology, Universiti Putra Malaysia, Serdang, Malaysia
| | - H-Y Chee
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| |
Collapse
|
11
|
Pedram B, Pasquetto V, Drame PM, Ji Y, Gonzalez-Moa MJ, Baldwin RK, Nutman TB, Biamonte MA. A novel rapid test for detecting antibody responses to Loa loa infections. PLoS Negl Trop Dis 2017; 11:e0005741. [PMID: 28749939 PMCID: PMC5531435 DOI: 10.1371/journal.pntd.0005741] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Accepted: 06/23/2017] [Indexed: 01/06/2023] Open
Abstract
Ivermectin-based mass drug administration (MDA) programs have achieved remarkable success towards the elimination of onchocerciasis and lymphatic filariasis. However, their full implementation has been hindered in Central Africa by the occurrence of ivermectin-related severe adverse events (SAEs) in a subset of individuals with high circulating levels of Loa loa microfilariae. Extending MDA to areas with coincident L. loa infection is problematic, and inexpensive point-of-care tests for L. loa are acutely needed. Herein, we present a lateral flow assay (LFA) to identify subjects with a serological response to Ll-SXP-1, a specific and validated marker of L. loa. The test was evaluated on serum samples from patients infected with L. loa (n = 109) and other helminths (n = 204), as well as on uninfected controls (n = 77). When read with the naked eye, the test was 94% sensitive for L. loa infection and was 100% specific when sera from healthy endemic and non-endemic controls or from those with S. stercoralis infections were used as the comparators. When sera of patients with O. volvulus, W. bancrofti, or M. perstans were used as the comparators, the specificity of the LFA was 82%, 87%, and 88%, respectively. A companion smartphone reader allowed measurement of the test line intensities and establishment of cutoff values. With a cutoff of 600 Units, the assay sensitivity decreased to 71%, but the specificity increased to 96% for O. volvulus, 100% for W. bancrofti, and 100% for M. perstans-infected individuals. The LFA may find applications in refining the current maps of L. loa prevalence, which are needed to eliminate onchocerciasis and lymphatic filariasis from the African continent.
Collapse
Affiliation(s)
- Bijan Pedram
- Drugs & Diagnostics for Tropical Diseases, San Diego, California, United States of America
| | - Valérie Pasquetto
- Drugs & Diagnostics for Tropical Diseases, San Diego, California, United States of America
| | - Papa M. Drame
- Laboratory of Parasitic Diseases, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Yongchang Ji
- Drugs & Diagnostics for Tropical Diseases, San Diego, California, United States of America
| | - Maria J. Gonzalez-Moa
- Drugs & Diagnostics for Tropical Diseases, San Diego, California, United States of America
| | | | - Thomas B. Nutman
- Laboratory of Parasitic Diseases, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Marco A. Biamonte
- Drugs & Diagnostics for Tropical Diseases, San Diego, California, United States of America
- * E-mail:
| |
Collapse
|
12
|
Poole CB, Li Z, Alhassan A, Guelig D, Diesburg S, Tanner NA, Zhang Y, Evans TC, LaBarre P, Wanji S, Burton RA, Carlow CKS. Colorimetric tests for diagnosis of filarial infection and vector surveillance using non-instrumented nucleic acid loop-mediated isothermal amplification (NINA-LAMP). PLoS One 2017; 12:e0169011. [PMID: 28199317 PMCID: PMC5310896 DOI: 10.1371/journal.pone.0169011] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Accepted: 11/19/2016] [Indexed: 11/26/2022] Open
Abstract
Accurate detection of filarial parasites in humans is essential for the implementation and evaluation of mass drug administration programs to control onchocerciasis and lymphatic filariasis. Determining the infection levels in vector populations is also important for assessing transmission, deciding when drug treatments may be terminated and for monitoring recrudescence. Immunological methods to detect infection in humans are available, however, cross-reactivity issues have been reported. Nucleic acid-based molecular assays offer high levels of specificity and sensitivity, and can be used to detect infection in both humans and vectors. In this study we developed loop-mediated isothermal amplification (LAMP) tests to detect three different filarial DNAs in human and insect samples using pH sensitive dyes for enhanced visual detection of amplification. Furthermore, reactions were performed in a portable, non-instrumented nucleic acid amplification (NINA) device that provides a stable heat source for LAMP. The efficacy of several strand displacing DNA polymerases were evaluated in combination with neutral red or phenol red dyes. Colorimetric NINA-LAMP assays targeting Brugia Hha I repeat, Onchocerca volvulus GST1a and Wuchereria bancrofti LDR each exhibit species-specificity and are also highly sensitive, detecting DNA equivalent to 1/10-1/5000th of one microfilaria. Reaction times varied depending on whether a single copy gene (70 minutes, O. volvulus) or repetitive DNA (40 min, B. malayi and W. bancrofti) was employed as a biomarker. The NINA heater can be used to detect multiple infections simultaneously. The accuracy, simplicity and versatility of the technology suggests that colorimetric NINA-LAMP assays are ideally suited for monitoring the success of filariasis control programs.
Collapse
Affiliation(s)
| | - Zhiru Li
- New England Biolabs, Ipswich, MA United States of America
| | - Andy Alhassan
- New England Biolabs, Ipswich, MA United States of America
| | - Dylan Guelig
- PATH, Seattle, Washington, United States of America
| | | | | | - Yinhua Zhang
- New England Biolabs, Ipswich, MA United States of America
| | | | - Paul LaBarre
- PATH, Seattle, Washington, United States of America
| | - Samuel Wanji
- Research Foundation in Tropical Diseases and Environment, Buea, Cameroon
| | | | | |
Collapse
|
13
|
Lagatie O, Merino M, Batsa Debrah L, Debrah AY, Stuyver LJ. An isothermal DNA amplification method for detection of Onchocerca volvulus infection in skin biopsies. Parasit Vectors 2016; 9:624. [PMID: 27906100 PMCID: PMC5134125 DOI: 10.1186/s13071-016-1913-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Accepted: 11/24/2016] [Indexed: 12/20/2022] Open
Abstract
Background Diagnostic procedures for the diagnosis of infection with the nematode parasite Onchocerca volvulus are currently based on the microscopic detection of microfilariae in skin biopsies. Alternative approaches based on amplification of parasitic DNA in these skin biopsies are currently being explored. Mostly this is based on the detection of the O-150 repeat sequence using PCR based techniques. Methods An isothermal, loop-mediated amplification method has been designed using the mitochondrial O. volvulus cox1 gene as a target. Results Analysis of dilution series of synthetic DNA containing the targeted sequence show a non-linear dose-response curve, as is usually the case for isothermal amplification methods. Evaluation of cross-reactivity with the heterologous sequence from the closely related parasites Wuchereria bancrofti, Loa loa and Brugia malayi demonstrated strong specificity, as none of these sequences was amplified. The assay however amplified both O. volvulus and O. ochengi DNA, but with a different melting point that can be used to discriminate between the species. Evaluation of this assay in a set of skin snip biopsies collected in an endemic area in Ghana showed a high correlation with O-150 qPCR and also demonstrated a similar sensitivity. Compared to qPCR, LAMP had a sensitivity of 88.2% and a specificity of 99.2%. Conclusions We have developed a sensitive and specific loop-mediated amplification method for detection of O. volvulus DNA in skin biopsies that is capable of providing results within 30 min. Electronic supplementary material The online version of this article (doi:10.1186/s13071-016-1913-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Ole Lagatie
- Janssen Diagnostics, Janssen R&D, Turnhoutseweg 30, 2340, Beerse, Belgium.
| | - Michelle Merino
- Janssen Diagnostics, Janssen R&D, Turnhoutseweg 30, 2340, Beerse, Belgium
| | - Linda Batsa Debrah
- Kumasi Centre for Collaborative Research into Tropical medicine, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana
| | - Alexander Y Debrah
- Faculty of Allied Health Sciences, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana
| | - Lieven J Stuyver
- Janssen Diagnostics, Janssen R&D, Turnhoutseweg 30, 2340, Beerse, Belgium
| |
Collapse
|