1
|
Kazberuk M, Pogorzelski P, Kuźma Ł, Kurasz A, Róg-Makal M, Matys U, Tokarewicz J, Kralisz P, Dobrzycki S. Wearable Cardioverter Defibrillator as a Treatment in Patients with Heart Failure of Various Aetiologies-A Series of Ten Cases Within the BIA-VEST Registry. J Clin Med 2024; 13:7686. [PMID: 39768607 PMCID: PMC11677621 DOI: 10.3390/jcm13247686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2024] [Revised: 12/12/2024] [Accepted: 12/15/2024] [Indexed: 01/11/2025] Open
Abstract
Background/Objectives: Sudden cardiac death (SCD) remains a major global health concern and represents one of the most common causes of mortality due to cardiovascular diseases. The wearable cardioverter-defibrillator (WCD) is an innovative, non-invasive medical device designed to provide continuous heart monitoring and immediate defibrillation in patients at risk for SCD. The study aimed to assess the efficacy of WCD usage in patients awaiting decision on therapy with implantable cardioverter-defibrillators (ICDs). Methods: We explored the clinical applications, benefits, and limitations of WCD usage within the BIA-VEST registry in Poland over the years 2021-2023. The study included 10 patients with a mean age of 49.1 ± 12.02 years. Results: All patients demonstrated good tolerance and compliance with the LifeVest WCD, wearing it for an average of 93.1 days, about 22.8 h per day (95.7% of the time). No interventions from LifeVests were recorded, and there were no effective, ineffective, or inadequate discharges. After the first follow-up echocardiography, five patients still required ICDs. Due to improved LVEF and overall condition in six out of ten patients undergoing WCD bridge therapy, ICD implantation was finally waived. Conclusions: The WCD acts as a bridge to therapy, such as ICD implantation or cardiac surgery, and may be particularly beneficial for patients with transient or evolving conditions, such as structural heart diseases and life-threatening ventricular arrhythmias.
Collapse
Affiliation(s)
- Małgorzata Kazberuk
- Department of Invasive Cardiology, Medical University of Białystok, 15-089 Białystok, Poland
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Lenormand T, Bodin A, Fauchier L. The Role of the Wearable Defibrillator in Heart Failure. Curr Heart Fail Rep 2024; 21:33-42. [PMID: 38236485 DOI: 10.1007/s11897-023-00641-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/29/2023] [Indexed: 01/19/2024]
Abstract
PURPOSE OF REVIEW Wearable cardioverter defibrillators (WCDs) have been developed as a temporary measure for protecting patients at risk for sudden cardiac death that do not meet the indication for implantable cardioverter defibrillator (ICD), most notably in the early stages of heart failure with reduced ejection fraction before reassessment of their left ventricular ejection fraction. In this review, we report available evidence in the literature and guidelines regarding WCD use in order to try to define the role WCDs may have in heart failure. RECENT FINDINGS In the last decade, most observational studies found WCDs to be both safe and effective in terminating ventricular arrhythmias in various indications, mostly centered around heart failure with reduced ejection fraction. The only available randomized controlled trial using WCD did not however show a benefit on patients' survival. Hence, recent guidelines only recommended its use in limited indications. Recent data also suggest a possible interest of WCD in monitoring patients, a finding that may prove useful in the context of new-onset heart failure. Data regarding WCD benefit is scarce, and definitive conclusions on its utility are hard to draw. In the context of heart failure, and particularly new-onset heart failure, WCD might find a role in a global comprehensive management of the disease, both acting as an educational tool, a monitoring tool, and, most importantly, a safe and effective tool in preventing sudden cardiac death. The low level of evidence however invites caution, and the decision of prescribing a WCD needs to be individualized and thoroughly discussed with the patient whose compliance is key with this device.
Collapse
Affiliation(s)
- Thibault Lenormand
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, Tours, France
| | - Alexandre Bodin
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, Tours, France
| | - Laurent Fauchier
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, Tours, France.
| |
Collapse
|
3
|
Alshoaibi N, Aljazar A, Bushnag M, Aseeri A, Baeesa L, Alruwaithi S, Bashawri R, Marouf A, Alsaeed R. Assessment of Psychological Implications and Quality of Life After Different Cardiac Device Implantation in Saudi Arabia. Cureus 2024; 16:e52338. [PMID: 38361709 PMCID: PMC10867300 DOI: 10.7759/cureus.52338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/15/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND Cardiac device therapy is likely to affect different aspects of patients' psychological well-being, such as their quality of life. The aim of this study was to examine the mental health status, specifically the conditions of depression and anxiety regarding implantable cardiac device patients. METHODS A cross-sectional retrospective study was conducted in January 2022. This study was conducted at King Abdul-Aziz University Hospital in Jeddah, Saudi Arabia. All patients aged more than 18 years old who underwent heart device implantation for six months or more formed the study population. A total of 30 implantable cardioverter defibrillator (ICD) subtypes were used in our patients (45.8%), including cardiac resynchronization therapy device (CRT-D) in seven patients (14.6%) and one subcutaneous ICD (2.1%). A pacemaker was used in 18 patients (37.5%). Binary logistic regression analysis was conducted to identify the association between type of cardiac implantation device and the likelihood of having abnormal depression and anxiety score. RESULTS A total of 48 patients participated in this study. Hypertension was the most frequently associated risk factor in our sample (64.6%; n=31). In comparison between ICD users and pacemaker users in terms of the SF-36 general health survey, a marginally significant difference was noted in the role of limitations due to emotional health (63 ± 28.6) for ICD patients compared to pacemaker patients (81.8 ± 28.1), (p=0.050). However, pacemaker patients showed a significant favourable social functioning score (90.1 ± 17.7) compared to ICD patients (71.5 ± 19), (p=0.001). There is no significant difference noted regarding the other domains. Binary logistic regression analysis identified that patients who are using ICD were seven times more likely to have abnormal anxiety score (odds ratio: 7.00 (95% confidence interval: 1.36-35.9) (p=0.020). CONCLUSION This study identified a potential association between cardiac devices and the anxiety and quality of life of patients. Nonetheless, further investigation is warranted to assess the psychological and physiological effects of cardiac device therapy on patients, in addition to examining the effects of implantation and follow-up on cardiac function and cardiac symptoms.
Collapse
Affiliation(s)
| | - Alaa Aljazar
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| | - Maal Bushnag
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| | - Afnan Aseeri
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| | - Layan Baeesa
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| | | | - Roba Bashawri
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| | - Amjad Marouf
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| | - Refan Alsaeed
- College of Medicine, King Abdulaziz University, Jeddah, SAU
| |
Collapse
|
4
|
Wild C, Götz G, Wernly B. Correspondence: Authors' reply to Critical appraisal of "Goetz G, Wernly B, Wild C (2023) Wearable cardioverter defibrillator for preventing sudden cardiac death in patients at risk: An updated systematic review of comparative effectiveness and safety. IJC Heart & Vasculature 45 (2023) 101189" by M. Nürnberg, F. Semrau. IJC HEART & VASCULATURE 2023; 49:101299. [PMID: 38059169 PMCID: PMC10696452 DOI: 10.1016/j.ijcha.2023.101299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 11/03/2023] [Accepted: 11/05/2023] [Indexed: 12/08/2023]
Affiliation(s)
- Claudia Wild
- Austrian Institute for Health Technology Assessment (AIHTA), Austria
| | - Gregor Götz
- Austrian Institute for Health Technology Assessment (AIHTA), Austria
| | - Bernhard Wernly
- Department of Internal Medicine, General Hospital Oberndorf, Teaching Hospital of the Paracelsus Medical University Salzburg, and Institute of General Practice, Family Medicine and Preventive Medicine, Paracelsus Medical University, Salzburg, Austria
| |
Collapse
|
5
|
Nürnberg M, Semrau F. Critical appraisal of "Goetz G, Wernly B, Wild C (2023) Wearable cardioverter defibrillator for preventing sudden cardiac death in patients at risk: An updated systematic review of comparative effectiveness and safety. IJC Heart & Vasculature 45 (2023) 101189". IJC HEART & VASCULATURE 2023; 48:101258. [PMID: 37680548 PMCID: PMC10480618 DOI: 10.1016/j.ijcha.2023.101258] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 08/16/2023] [Accepted: 08/16/2023] [Indexed: 09/09/2023]
Affiliation(s)
- Michael Nürnberg
- Hospital Ottakring/Wilhelminenspital, 3. Med. Div. of Cardiology with ICU, Vienna, Austria
| | | |
Collapse
|
6
|
Marijon E, Narayanan K, Smith K, Barra S, Basso C, Blom MT, Crotti L, D'Avila A, Deo R, Dumas F, Dzudie A, Farrugia A, Greeley K, Hindricks G, Hua W, Ingles J, Iwami T, Junttila J, Koster RW, Le Polain De Waroux JB, Olasveengen TM, Ong MEH, Papadakis M, Sasson C, Shin SD, Tse HF, Tseng Z, Van Der Werf C, Folke F, Albert CM, Winkel BG. The Lancet Commission to reduce the global burden of sudden cardiac death: a call for multidisciplinary action. Lancet 2023; 402:883-936. [PMID: 37647926 DOI: 10.1016/s0140-6736(23)00875-9] [Citation(s) in RCA: 51] [Impact Index Per Article: 25.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 04/13/2023] [Accepted: 04/25/2023] [Indexed: 09/01/2023]
Abstract
Despite major advancements in cardiovascular medicine, sudden cardiac death (SCD) continues to be an enormous medical and societal challenge, claiming millions of lives every year. Efforts to prevent SCD are hampered by imperfect risk prediction and inadequate solutions to specifically address arrhythmogenesis. Although resuscitation strategies have witnessed substantial evolution, there is a need to strengthen the organisation of community interventions and emergency medical systems across varied locations and health-care structures. With all the technological and medical advances of the 21st century, the fact that survival from sudden cardiac arrest (SCA) remains lower than 10% in most parts of the world is unacceptable. Recognising this urgent need, the Lancet Commission on SCD was constituted, bringing together 30 international experts in varied disciplines. Consistent progress in tackling SCD will require a completely revamped approach to SCD prevention, with wide-sweeping policy changes that will empower the development of both governmental and community-based programmes to maximise survival from SCA, and to comprehensively attend to survivors and decedents' families after the event. International collaborative efforts that maximally leverage and connect the expertise of various research organisations will need to be prioritised to properly address identified gaps. The Commission places substantial emphasis on the need to develop a multidisciplinary strategy that encompasses all aspects of SCD prevention and treatment. The Commission provides a critical assessment of the current scientific efforts in the field, and puts forth key recommendations to challenge, activate, and intensify efforts by both the scientific and global community with new directions, research, and innovation to reduce the burden of SCD worldwide.
Collapse
Affiliation(s)
- Eloi Marijon
- Division of Cardiology, European Georges Pompidou Hospital, AP-HP, Paris, France; Université Paris Cité, Inserm, PARCC, Paris, France; Paris-Sudden Death Expertise Center (Paris-SDEC), Paris, France.
| | - Kumar Narayanan
- Université Paris Cité, Inserm, PARCC, Paris, France; Paris-Sudden Death Expertise Center (Paris-SDEC), Paris, France; Medicover Hospitals, Hyderabad, India
| | - Karen Smith
- School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia; Silverchain Group, Melbourne, VIC, Australia
| | - Sérgio Barra
- Department of Cardiology, Hospital da Luz Arrábida, Vila Nova de Gaia, Portugal
| | - Cristina Basso
- Cardiovascular Pathology Unit-Azienda Ospedaliera and Department of Cardiac Thoracic and Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Marieke T Blom
- Department of General Practice, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Lia Crotti
- Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy; Istituto Auxologico Italiano, IRCCS, Center for Cardiac Arrhythmias of Genetic Origin, Cardiomyopathy Unit and Laboratory of Cardiovascular Genetics, Department of Cardiology, Milan, Italy
| | - Andre D'Avila
- Department of Cardiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Department of Cardiology, Hospital SOS Cardio, Santa Catarina, Brazil
| | - Rajat Deo
- Department of Cardiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| | - Florence Dumas
- Université Paris Cité, Inserm, PARCC, Paris, France; Paris-Sudden Death Expertise Center (Paris-SDEC), Paris, France; Emergency Department, Cochin Hospital, Paris, France
| | - Anastase Dzudie
- Cardiology and Cardiac Arrhythmia Unit, Department of Internal Medicine, DoualaGeneral Hospital, Douala, Cameroon; Yaounde Faculty of Medicine and Biomedical Sciences, University of Yaounde 1, Yaounde, Cameroon
| | - Audrey Farrugia
- Hôpitaux Universitaires de Strasbourg, France, Strasbourg, France
| | - Kaitlyn Greeley
- Division of Cardiology, European Georges Pompidou Hospital, AP-HP, Paris, France; Université Paris Cité, Inserm, PARCC, Paris, France; Paris-Sudden Death Expertise Center (Paris-SDEC), Paris, France
| | | | - Wei Hua
- Cardiac Arrhythmia Center, FuWai Hospital, Beijing, China
| | - Jodie Ingles
- Centre for Population Genomics, Garvan Institute of Medical Research and UNSW Sydney, Sydney, NSW, Australia
| | - Taku Iwami
- Kyoto University Health Service, Kyoto, Japan
| | - Juhani Junttila
- MRC Oulu, University of Oulu and Oulu University Hospital, Oulu, Finland
| | - Rudolph W Koster
- Heart Center, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | | | - Theresa M Olasveengen
- Department of Anesthesia and Intensive Care Medicine, Oslo University Hospital and Institute of Clinical Medicine, Oslo, Norway
| | - Marcus E H Ong
- Singapore General Hospital, Duke-NUS Medical School, Singapore
| | - Michael Papadakis
- Cardiovascular Clinical Academic Group, St George's University of London, London, UK
| | | | - Sang Do Shin
- Department of Emergency Medicine at the Seoul National University College of Medicine, Seoul, South Korea
| | - Hung-Fat Tse
- University of Hong Kong, School of Clinical Medicine, Queen Mary Hospital, Hong Kong Special Administrative Region, China; Cardiac and Vascular Center, The University of Hong Kong-Shenzhen Hospital, Shenzhen, China
| | - Zian Tseng
- Division of Cardiology, UCSF Health, University of California, San Francisco Medical Center, San Francisco, California
| | - Christian Van Der Werf
- University of Amsterdam, Heart Center, Amsterdam, Netherlands; Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Fredrik Folke
- Department of Cardiology, Copenhagen University Hospital - Herlev and Gentofte, Herlev, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Christine M Albert
- Department of Cardiology, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Bo Gregers Winkel
- Department of Cardiology, University Hospital Copenhagen, Rigshospitalet, Copenhagen, Denmark
| |
Collapse
|
7
|
Goetz G, Wernly B, Wild C. Wearable cardioverter defibrillator for preventing sudden cardiac death in patients at risk: An updated systematic review of comparative effectiveness and safety. IJC HEART & VASCULATURE 2023; 45:101189. [PMID: 37025482 PMCID: PMC10070821 DOI: 10.1016/j.ijcha.2023.101189] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 02/08/2023] [Accepted: 02/21/2023] [Indexed: 03/29/2023]
Abstract
Objectives To synthesise the available evidence of wearable cardioverter defibrillator (WCD) therapy as an add-on measure to optimal medical therapy (OMT) or as a replacement of hospital stay. Methods An update systematic review (SR) of comparative effectiveness and safety of WCD therapy was conducted. We included randomised controlled trials (RCT), prospective comparative studies and prospective uncontrolled studies with at least 100 patients. A narrative synthesis of the evidence was conducted. Results One RCT (n = 2348) and further eleven observational studies (n = 5345) fulfilled our inclusion criteria. In the only available RCT, the use of the WCD was not statistically associated with a clinical benefit on arrhythmic mortality in post-myocardial infarction (MI) patients with an ejection fraction of ≤35%. The compliance with WCD therapy was low in the RCT and high in observational studies, with ten observational studies reporting on a daily wear time between 20 and 23.5 h. The range of percentage of patients receiving at least one appropriate shock was 1-4.8% and the rate of first shock success was reported to be 100% in three studies. Serious adverse events (SAEs) such as inappropriate shocks occurred rarely, with between 0% and 2% of patients being inappropriately shocked within ten observational studies. In one of the observational studies, two patients (2%) were allergic to nickel developing skin rash and false alarms occurred in 58 patients (57%) in this study. Another registry study (n = 448) reported milder AEs, such as dermatitis and pressure marks, occurring in 0.9% and 0.2% of enrolled patients, respectively. Conclusion The only available RCT failed to show superiority of add-on use of WCD in post MI patients. Observational evidence shows that the compliance with WCD is good, but the evidence is afflicted with selection bias and the inclusion of diverse mixed patient populations diluting the ability to draw indication-specific conclusions on the utility of the device. More comparative data is needed to justify continuing or expanding use of WCD therapy.
Collapse
Affiliation(s)
- Gregor Goetz
- HTA Austria - Austrian Institute for Health Technology Assessment GmbH, Vienna, Austria
- Department of Health Care Management, Technical University Berlin, Germany
| | - Bernhard Wernly
- Institute of general practice, family medicine and preventive medicine, Strubergasse 21, 5020 Paracelsus Medical University, Salzburg, Austria
- Department of Internal Medicine, Teaching Hospital of the Paracelsus Medical University Salzburg, General Hospital Oberndorf, Paracelsus Medical University Salzburg, Oberndorf, Austria
| | - Claudia Wild
- HTA Austria - Austrian Institute for Health Technology Assessment GmbH, Vienna, Austria
| |
Collapse
|
8
|
Aidelsburger P, Seyed-Ghaemi J, Bonderman D. Patient-reported outcomes using a wearable cardioverter-defibrillator: results from a systematic review. Int J Technol Assess Health Care 2023; 39:e1. [PMID: 36606325 PMCID: PMC11574545 DOI: 10.1017/s0266462322003300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 11/05/2022] [Accepted: 11/26/2022] [Indexed: 01/07/2023]
Abstract
OBJECTIVES The aim of this study was to assess the effect of the wearable cardioverter-defibrillator (WCD) on patient-reported outcomes (PRO) in adult patients with high risk for sudden cardiac arrest. METHODS We performed a systematic literature search in Medline (via PubMed) and Cochrane Library in February 2022 and included studies with a study population ≥18 years and prescribed WCD. PRO include health-related quality of life (QoL), symptoms, utilities, or satisfaction ratings. Study selection was done by two reviewers independently using predefined inclusion and exclusion criteria. Quality assessment of studies as well as data extraction was performed by one author and approved by a second author. Results of the included studies are presented quantitatively. RESULTS One randomized controlled trial (RCT), one comparative non-randomized trial, and three single-arm trials were included. QoL was assessed in four studies, but with different assessment tools. One study additionally evaluated the change in depressive symptoms and anxiety and one study focused on acceptability of WCD but evaluated items that are closely related to QoL. Results of the RCT show no statistically significant difference in QoL assessed by SF-36 and EQ-5D comparing WCD and Guideline-Directed Medical Therapy (GDMT) versus GDMT alone. One comparative study reports an improvement in depressive symptoms and anxiety within groups but no significant difference between groups. Further, one single-arm study reported improvement in QoL between baseline and day 90 and day 180. CONCLUSIONS The available evidence demonstrates that the usage of WCD is not affecting PRO, like QoL, depressive symptoms or anxiety negatively.
Collapse
Affiliation(s)
| | | | - Diana Bonderman
- Medical University of Vienna, Vienna, Austria
- Favoriten Clinic, Vienna, Austria
| |
Collapse
|
9
|
Relationship Between Resilience and Perceived Control After Acute Coronary Syndrome: A Prospective Study. J Cardiovasc Nurs 2023; 38:E20-E30. [PMID: 35297392 DOI: 10.1097/jcn.0000000000000898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Patients with acute coronary syndrome report poor health-related quality of life and decreased levels of perceived control. Perceived control is a person's belief that they can cope with negative events. Resilience is an adaptation that gives people the capacity to recover from difficult situations, and higher levels of resilience may impact recovery after an acute event. OBJECTIVE The aim of this study was to analyze the relationship between resilience, perceived control, and health outcomes of patients hospitalized with acute coronary syndrome within 6 months of discharge. METHODS Data were collected prospectively from adult patients hospitalized with acute coronary syndrome in 3 university hospitals in the Tokyo Metropolitan area, Japan. All data were collected between December 2015 and December 2019. The Sukemune-Hiew Resilience Test (part 1) was used to measure resilience, which includes 3 domains of social support, self-efficacy, and sociality. The Control Attitudes Scale-Revised was used to measure perceived control. Linear regression and path analysis were used to statistically analyze the relationship among variables. RESULTS Higher resilience, especially self-efficacy, was associated with higher perceived control during admission. Higher resilience, especially social support, during admission was associated with perceived control at 6 months after adjusting for income and education. Higher resilience during admission was associated with better perceived control at 3 months, which was associated with better health outcomes at 6 months. Higher income and lower depression were related to higher resilience. CONCLUSIONS Nurses should make sure patients with depression, low income, and low social support are connected with appropriate treatment and social support resources.
Collapse
|
10
|
Zhang H, Wang Y, Cai X, Tang N, Wei S, Yang Y. Family functioning and health-related quality of life of inpatients with coronary heart disease: a cross-sectional study in Lanzhou city, China. BMC Cardiovasc Disord 2022; 22:397. [PMID: 36068504 PMCID: PMC9446873 DOI: 10.1186/s12872-022-02844-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 08/25/2022] [Indexed: 11/21/2022] Open
Abstract
Background A key outcome in coronary heart disease (CHD) is Health Related Quality of Life (HRQoL), and family functioning is important in the management of CHD. But few studies have examined both together, and little is known about them among inpatients with CHD in less developed areas of China. Therefore, this study aimed to assess the HRQoL and family functioning status of inpatients with CHD in Lanzhou from Northwest China, and identify the factors that affect their HRQoL. Methods A cross‑sectional study was conducted in 224 CHD inpatients at one major hospital. Sociodemographic data and disease information of CHD inpatients were collected by face-to-face using a structured questionnaire and data were also obtained from patient medical records. HRQoL was measured using the Sickness Impact Profile (SIP). Family functioning was measured using the family APGAR index. Multiple binary logistic regression analysis (MBLRA) was used to explore potential risk factors associated with HRQoL, and Pearson’s correlations were used to assess the relationship between family functioning and HRQoL. Results The overall, physical and psychosocial SIP scores were 25.03 ± 8.52, 18.61 ± 9.90 and 28.08 ± 9.64, respectively. The total family APGAR score was 6.11 ± 2.45. MBLRA found older age, poorer cardiac function and more severe disease were associated with poorer HRQoL, while better family functioning, higher monthly income, and urban living were associated with better HRQoL. Family functioning was weakly to moderately correlated with total and psychosocial HRQoL. Conclusions Older and less affluent inpatients with lower educational level, less family support and more severe CHD have poorest quality of life, and health care providers should consider interventions to support them. Supplementary Information The online version contains supplementary material available at 10.1186/s12872-022-02844-x.
Collapse
Affiliation(s)
- Hongchen Zhang
- School of Nursing, Lanzhou University, Lanzhou, 730000, Gansu, China
| | - Yanhong Wang
- School of Nursing, Lanzhou University, Lanzhou, 730000, Gansu, China
| | - Xiaoqing Cai
- Department of Cardiology, The 940th Hospital of Joint Logistic Support Force of PLA, Lanzhou, 730050, Gansu, China
| | - Nan Tang
- School of Nursing, Lanzhou University, Lanzhou, 730000, Gansu, China
| | - Siqi Wei
- School of Nursing, Lanzhou University, Lanzhou, 730000, Gansu, China
| | - Yanwei Yang
- Department of Stomatology, The 940th Hospital of Joint Logistic Support Force of PLA, No. 333 South Binhe Road, Qilihe District, Lanzhou, 730050, Gansu, China.
| |
Collapse
|
11
|
Willy K, Ellermann C, Reinke F, Rath B, Wolfes J, Eckardt L, Doldi F, Wegner FK, Köbe J, Morina N. The Impact of Cardiac Devices on Patients’ Quality of Life—A Systematic Review and Meta-Analysis. J Cardiovasc Dev Dis 2022; 9:jcdd9080257. [PMID: 36005421 PMCID: PMC9409697 DOI: 10.3390/jcdd9080257] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/03/2022] [Accepted: 08/06/2022] [Indexed: 12/13/2022] Open
Abstract
The implantation of cardiac devices significantly reduces morbidity and mortality in patients with cardiac arrhythmias. Arrhythmias as well as therapy delivered by the device may impact quality of life of patients concerned considerably. Therefore we aimed at conducting a systematic search and meta-analysis of trials examining the impact of the implantation of cardiac devices, namely implantable cardioverter-defibrillators (ICD), pacemakers and left-ventricular assist devices (LVAD) on quality of life. After pre-registering the trial with the PROSPERO database, we searched Medline, PsycINFO, Web of Science and the Cochrane databases for relevant publications. Study quality was assessed by two independent reviewers using standardized protocols. A total of 37 trials met our inclusion criteria. Of these, 31 trials were cohort trials while 6 trials used a randomized controlled design. We found large pre-post effect sizes for positive associations between quality of life and all types of devices. The effect sizes for LVAD, pacemaker and ICD patients were g = 1.64, g = 1.32 and g = 0.64, respectively. There was a lack of trials examining the effect of implantation on quality of life relative to control conditions. Trials assessing quality of life in patients with cardiac devices are still scarce. Yet, the existing data suggest beneficial effects of cardiac devices on quality of life. We recommend that clinical trials on cardiac devices routinely assess quality of life or other parameters of psychological well-being as a decisive study endpoint. Furthermore, improvements in psychological well-being should influence decisions about implantations of cardiac devices and be part of patient education and may impact shared decision-making.
Collapse
Affiliation(s)
- Kevin Willy
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
- Department of Psychology, University of Münster, 48149 Münster, Germany
- Correspondence: ; Tel.: +49-251-83-44949; Fax: +49-251-83-52980
| | - Christian Ellermann
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Florian Reinke
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Benjamin Rath
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Julian Wolfes
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Lars Eckardt
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Florian Doldi
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Felix K. Wegner
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Julia Köbe
- Department for Cardiology II: Electrophysiology, University Hospital Münster, 48149 Münster, Germany
| | - Nexhmedin Morina
- Department of Psychology, University of Münster, 48149 Münster, Germany
| |
Collapse
|
12
|
Olic JJ, Stöllberger C, Schukro C, Odening KE, Reuschel E, Fischer M, Veltmann C, Duncker D, Baessler A. Usage of the wearable cardioverter-defibrillator during pregnancy. IJC HEART & VASCULATURE 2022; 41:101066. [PMID: 35676917 PMCID: PMC9168609 DOI: 10.1016/j.ijcha.2022.101066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/15/2022] [Accepted: 05/25/2022] [Indexed: 11/25/2022]
Abstract
Background Pregnancy can trigger or aggravate the risk for life-threating arrhythmias in cardiac diseases. Pregnancy is associated with reluctance for implantable cardioverter-defibrillators (ICD) due to concerns about radiation. Thus, the wearable cardioverter-defibrillator (WCD) might be an option during pregnancy. Aim of the study was to collect experiences about the use of WCD in pregnancy. Methods and results This study retrospectively included eight women who received a WCD during pregnancy. They suffered from ventricular tachycardia (VT) without known cardiac disease (n = 3), Brugada syndrome (n = 1), hypertrophic cardiomyopathy (n = 1), dilated cardiomyopathy (n = 1), non-compaction (n = 1), and survived sudden cardiac arrest during a preceding pregnancy (n = 1). WCD usage was started between 13 and 28 weeks of gestation. WCD wearing period ranged from 3 days to 30.9 weeks, WCD wearing time ranged from 13.0 to 23.7 h per day. Two women (25%) abandoned WCD already during pregnancy. Neither appropriate nor inappropriate WCD shocks were recorded. Antiarrhythmic management included beta-blockers (n = 5) and flecainide (n = 2). After delivery, ICD were implanted (n = 4), refused (n = 2) and estimated not necessary after successful catheter ablation (n = 2). Conclusion Uneventful pregnancy is possible in women at risk for sudden cardiac death by interdisciplinary monitoring and diligent pharmacotherapy protected by the WCD. Since no WCD shocks were recorded, the effectiveness of WCD during pregnancy is still unclear. However, arrhythmia detection by WCD was very good despite the changed anatomy in pregnancy. Nevertheless, further studies are necessary to assess effectiveness of WCD in pregnant women. Furthermore, efforts should be made to increase the wearing adherence of WCD during pregnancy.
Collapse
Affiliation(s)
- J.-Jacqueline Olic
- Department of Cardiology, University Hospital of Regensburg, Regensburg, Germany
| | | | - Christoph Schukro
- Department for Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Katja E. Odening
- Translational Cardiology, Department of Cardiology and Institute of Physiology, University Hospital Bern, University of Bern, Switzerland
| | - Edith Reuschel
- University Department of Obstetrics and Gynecology At The Hospital St. Hedwig of The Order of St. John, University of Regensburg, 93049 Regensburg, Germany
| | - Marcus Fischer
- Department of Cardiology, University Hospital of Regensburg, Regensburg, Germany
| | - Christian Veltmann
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany
| | - David Duncker
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany
| | - Andrea Baessler
- Department of Cardiology, University Hospital of Regensburg, Regensburg, Germany
| |
Collapse
|
13
|
Kurokawa T, Arimoto T, Hashimoto N, Koyama K, Watanabe K, Kutsuzawa D, Kato S, Watanabe T, Yaguchi Y, Suzuki T, Watanabe M. Contact dermatitis associated with wearable cardioverter-defibrillator. J Cardiol Cases 2022; 25:266-268. [DOI: 10.1016/j.jccase.2021.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 10/06/2021] [Accepted: 10/27/2021] [Indexed: 11/26/2022] Open
|
14
|
Alzahrani A, Alqahtani A, Saleh A, Aloqalaa M, Abdulmajeed A, Nadhrah A, Alhazmi N. Quality of life of cardiac outpatients with and without psychiatric disorders: a cross-sectional study. THE EGYPTIAN JOURNAL OF NEUROLOGY, PSYCHIATRY AND NEUROSURGERY 2022. [DOI: 10.1186/s41983-021-00444-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
The study aims to measure the quality of life (QOL) for cardiac outpatients with psychiatric disorders (CPP) in comparison to cardiac outpatients without psychiatric disorders (CPOP). A semi-structured interview was performed for consecutive cardiac outpatients. Psychiatric diagnoses were confirmed using the mini-international neuropsychiatric interview (MINI). The QOL was measured by the World Health Organization quality of life (WHOQOL-BREF).
Results
Out of the 343 enrolled patients, 93 (27.1%) patients were found to have psychiatric disorders. The WHO-BREF score of QOL was 4.25 ± 0.85. The CPP were found to have statistically significant lower scores in QOL than CPOP in all the WHOQOL-BREF domains. Particularly, the domain of psychological health showed the highest difference between the two groups (76.9 vs. 87.8, P < 0.001), whereas the environment domain showed the lowest difference between them (80.2 vs. 87.9, P < 0.001). Within each QOL domain, patients with congestive heart failure and psychiatric disorders showed the lowest QOL in both the physical domain (51.4 vs. 71.3, P < 0.02) and the social domain (64.7 vs. 81.9, P < 0.05), while patients with vulvular heart disease and psychiatric disorders showed the lowest QOL in the psychological domain (74.6 vs. 85.7, P < 0.001) and patients with arrhythmias and psychiatric disorders in the environment domain (80 vs. 86.2, P < 0.02).
Conclusions
The QOL of CPP were found to have poorer QOL than CPOP. The magnitude of difference in QOL was the highest in the psychological health domain and the lowest in the environment domain.
Collapse
|
15
|
Depressive symptoms in patients after primary and secondary prophylactic ICD implantation. Clin Res Cardiol 2021; 111:1210-1218. [PMID: 34779916 DOI: 10.1007/s00392-021-01940-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 09/06/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVE Implantable cardioverter defibrillators (ICD) are successfully used to treat life-threatening arrhythmias and prevent sudden cardiac death. However, they are also known to have a major psychological impact leading to higher prevalence of depression and anxiety in a substantial proportion of patients. The aim of this study was to assess the prevalence of depressive symptoms in a large cohort of ICD carriers with a different clinical background and to compare prevalence and risk factors between patients with primary and secondary prophylactic indication for ICD implantation. METHODS 315 out of 622 patients (50.6%), who regularly attended ICD assessments at the University Hospital Zurich completed the Beck Depression Inventory (BDI I-II) to estimate current depressive symptoms. RESULTS Overall, depressive symptoms were common in ICD patients, with 20.3% of the patients showing clinically relevant depression (12.4% mild depressive symptoms, 6.0% moderate, 1.9% severe). Moderate to severe depressive symptoms seem to be more likely in patients with secondary prophylactic indication of the ICD as compared to a group of patients with primary prophylactic implantation. Patients that received more than 5 ICD shocks since implantation reveal more depressive symptoms than those with less events. Mean BDI Score in total (n = 315) was at 8.44 ± 7.56 without a statistically significant difference between the primary (M = 8.04 ± 7.10, n = 153) and secondary (M = 8.81 ± 7.98, n = 162) preventive group (p value = 0.362), even after adjustment for various clinical characteristics. ICD patients should therefore be well supported and advised concerning the psychological impact of their device and particular aspects of daily life concerns (e.g. physical activity), with a special focus on patients, who have received multiple shocks.
Collapse
|
16
|
Increased Quality of Life Among Newly Diagnosed Patients With Heart Failure With Reduced Ejection Fraction in the Months After Initiation of Guideline-Directed Medical Therapy and Wearable Cardioverter Defibrillator Prescription. J Cardiovasc Nurs 2021; 36:589-594. [PMID: 34608886 DOI: 10.1097/jcn.0000000000000864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND The patient experience of heart failure involves a multi-impact symptom response with functional limitations, psychological changes, and significant treatment burden. OBJECTIVE The aim of this study was to examine the change in patient-reported outcomes in newly diagnosed patients with heart failure and reduced ejection fraction (HFrEF) prescribed a wearable cardioverter defibrillator. METHODS Adults hospitalized for new-onset heart failure, due to ischemic or nonischemic cardiomyopathy, and prescribed a wearable cardioverter defibrillator within 10 days post discharge were approached for inclusion. Participants completed the Kansas City Cardiomyopathy Questionnaire at 3 time points: baseline, day 90, and day 180. RESULTS A total of 210 patients (26% female) were included. All Kansas City Cardiomyopathy Questionnaire subscales (physical limitation, symptom frequency, quality of life, and social limitation) showed improvement from baseline to day 90 (all Ps < .001). Only quality of life continued to improve from day 90 to day 180 (P < .001). By day 90, nearly 70% of patients showed an improvement in quality of life (67.9%, n = 91), and by day 180, more than 80% (82.8%, n = 111) reported a net improvement. Five patients (3.7%) reported a net decrease, and 18 patients (13.4%) had no net change in quality of life during the 180-day period. CONCLUSION Patient-reported quality of life improved significantly among patients newly diagnosed with HFrEF and prescribed a wearable cardioverter defibrillator. These results suggest that pursuing guideline-directed medical therapy for HFrEF, while being protected by the wearable cardioverter defibrillator, is likely to provide symptom relief and improve quality of life.
Collapse
|
17
|
High Incidence of Inappropriate Alarms in Patients with Wearable Cardioverter-Defibrillators: Findings from the Swiss WCD Registry. J Clin Med 2021; 10:jcm10173811. [PMID: 34501258 PMCID: PMC8432131 DOI: 10.3390/jcm10173811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/15/2021] [Accepted: 08/16/2021] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The wearable cardioverter defibrillator (WCD) uses surface electrodes to detect arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. OBJECTIVE The aim of this study is to assess the alarm burden in patients and its impact on clinical outcomes. METHODS Patients from the nationwide Swiss WCD Registry were included. Clinical characteristics and data were obtained from the WCDs. Arrhythmia recordings ≥30 s in length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia (SVT) or artefact. RESULTS A total of 10653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0 ± 1.6 months. Episode duration was 30 s or more in 2996 alarms (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) SVT). Two-hundred and seven patients (45%) had three or more alarms per month. Obesity was significantly associated with three or more alarms per month (p = 0.01, 27.7% vs. 15.9%). High alarm burden was not associated with a lower average daily wear time (20.8 h vs. 20.7 h, p = 0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs. 47.3%, p = 0.156). CONCLUSIONS In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden was associated with obesity but did not lead to a decreased adherence.
Collapse
|
18
|
Sears SF, Tripp C, Huber NL, Khan S, Nekkanti R, Burch AE, Pokorney SD. Collaborative care for the wearable cardioverter defibrillator patient: Getting the patient and medical team "vested and active". J Cardiovasc Electrophysiol 2020; 31:2509-2515. [PMID: 32757437 DOI: 10.1111/jce.14708] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 07/24/2020] [Accepted: 07/24/2020] [Indexed: 01/10/2023]
Abstract
Patients with a reduced ejection fraction of 35% or less and a history of myocardial infarction (MI) are at increased risk of sudden cardiac death (SCD). These patients have a class I indication for an implantable cardioverter-defibrillator after allowing time for medical therapy optimization and potential cardiac recovery. The rates of SCD are highest in this "gap" period early after a cardiac event, and the wearable cardioverter-defibrillator (WCD) is an intervention that can be used to protect against SCD during this time period. There has been a clinical trial that randomized patients with a reduced ejection fraction at the time of MI to a WCD versus control. Results of the trial showed no statistically significant difference in the primary endpoint of SCD. There are many intricacies to the interpretation of the trial, including the importance of patient adherence to WCD therapy, which is affected by the patient experience and psychological factors. Patients with a new cardiomyopathy are affected by a mix of psychological factors, including the feeling of safety and protection from a WCD contrasted by the WCD providing a reminder of awareness and fear of ventricular arrhythmias and SCD. Beyond the capabilities of a WCD to defibrillate a life-threatening ventricular arrhythmia, the device can also provide activity and heart failure diagnostics monitoring. Patients need to be engaged in shared decision-making conversations about a WCD, so that patients can make a decision based on their own values construct, ultimately increasing adherence among the patients that want a WCD.
Collapse
Affiliation(s)
- Samuel F Sears
- Department of Psychology, East Carolina University, Greenville, North Carolina, USA.,Department of Cardiovascular Sciences, East Carolina University, Greenville, North Carolina, USA
| | - Connor Tripp
- Department of Psychology, East Carolina University, Greenville, North Carolina, USA
| | - Nichelle L Huber
- Department of Psychology, East Carolina University, Greenville, North Carolina, USA
| | - Saleen Khan
- Department of Cardiovascular Sciences, East Carolina University, Greenville, North Carolina, USA
| | - Rajasekhar Nekkanti
- Department of Cardiovascular Sciences, East Carolina University, Greenville, North Carolina, USA
| | - Ashley E Burch
- Department of Psychology, East Carolina University, Greenville, North Carolina, USA.,Department of Cardiovascular Sciences, East Carolina University, Greenville, North Carolina, USA.,Division of Cardiology, Duke University, Durham, North Carolina, USA
| | - Sean D Pokorney
- Division of Cardiology, Duke University, Durham, North Carolina, USA
| |
Collapse
|
19
|
Bahall M, Legall G, Khan K. Quality of life among patients with cardiac disease: the impact of comorbid depression. Health Qual Life Outcomes 2020; 18:189. [PMID: 32552773 PMCID: PMC7302374 DOI: 10.1186/s12955-020-01433-w] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Accepted: 06/03/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Patients with cardiac disease with or without depression may also have major physical and mental problems. This study assesses and compares the quality of life (QOL) of patients with cardiac disease with and without depression and accompanying comorbidities. METHODS A cross-sectional study was conducted with a convenience sample of 388 patients with cardiac disease. The 12-item Short-Form (SF-12)-patient was used to measure physical component scale (PCS) and mental component scale (MCS) QOL, and the Patient Health Questionnaire (PHQ-9) was used to measure depression. The Charlson Comorbidity Index was used to estimate 10-year survival probability. Descriptive statistics, analysis of covariance (ANCOVA), chi-square tests, and binary logistic regression were used for analysis. RESULTS The prevalence of minimal to mild depression was 65.7% [(95% CI (60.8, 70.4)] and that of moderate to severe depression was 34.3% [95% CI (29.6, 39.2)]. There was no significant association between the level of PHQ-categorised depression and age (p = 0.171), sex (p = 0.079), or ethnicity (p = 0.407). The overall mean PCS and MCS QOL was 32.5 [95% CI (24.4, 40.64)] and 45.4 [95% CI (44.4, 46.4)], respectively, with no significant correlation between PCS and MCS [r (Pearson's) = 0.011; p = 0.830)]. There were QOL differences among the five PHQ categories (PCS: p = 0.028; MCS: p ≤ 0.001) with both MCS and PCS decreasing with increasing depression. ANCOVA (with number of comorbidities as the covariate) showed a significant age × ethnicity interaction for PCS (p = 0.044) and MCS (p = 0.039), respectively. Young Indo-Trinidadians had significantly lower PCS than did Afro-Trinidadians, while the converse was true for MCS. Depression, age, and number of comorbidities were predictors of PCS, while depression, age, and sex were predictors of MCS. CONCLUSIONS Increasing severity of depression worsened both PCS and MCS QOL. Age and level of clinical depression predicted QOL, with number of comorbidities predicting only PCS and sex predicting only MCS. Efforts must be made to treat depression in all age groups of patients with cardiac disease.
Collapse
Affiliation(s)
- Mandreker Bahall
- School of Medicine, Faculty of Medical Sciences, University of the West Indies, Eric Williams Medical Sciences Complex, Mt Hope, House #57 LP 62, Calcutta Road Number 3, Mc Bean, Couva, Trinidad, Trinidad and Tobago.
| | - George Legall
- School of Medicine, Faculty of Medical Sciences, University of the West Indies, Eric Williams Medical Sciences Complex, Mt Hope, House #57 LP 62, Calcutta Road Number 3, Mc Bean, Couva, Trinidad, Trinidad and Tobago
| | - Katija Khan
- School of Medicine, Faculty of Medical Sciences, University of the West Indies, Eric Williams Medical Sciences Complex, Mt Hope, House #57 LP 62, Calcutta Road Number 3, Mc Bean, Couva, Trinidad, Trinidad and Tobago
| |
Collapse
|
20
|
Cheung CC, Olgin JE, Lee BK. Wearable cardioverter-defibrillators: A review of evidence and indications. Trends Cardiovasc Med 2020; 31:196-201. [PMID: 32205034 DOI: 10.1016/j.tcm.2020.03.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 02/22/2020] [Accepted: 03/02/2020] [Indexed: 11/28/2022]
Abstract
The wearable cardioverter-defibrillator (WCD) was first approved for clinical use in 2002, and is routinely used in select populations at high risk for sudden cardiac death. WCDs are frequently considered as a bridge to definitive therapy or in circumstances where insertion of conventional implantable cardioverter-defibrillators (ICD) is temporarily contraindicated. In this review, we summarize the literature on WCDs. From prospective trials to the first randomized controlled trial with WCD, there is a growing body of evidence that suggests that the WCD is safe and effective. In the first randomized controlled trial of the WCD (VEST Trial), there was no reduction in arrhythmia death but there was a reduction in all-cause mortality. We discuss the mortality impact, rate of inappropriate shocks, compliance, and potential quality of life implications with the WCD. Finally, we present the evidence for WCD use in select populations (e.g., post-myocardial infarction, device extraction), and the current guideline recommendations for WCD use.
Collapse
Affiliation(s)
- Christopher C Cheung
- Division of Cardiology, Electrophysiology and Arrhythmia Service, University of California, San Francisco. 500 Parnassus Avenue, Box 1354, MU 429, San Francisco, CA 94143-1354, United States.
| | - Jeffrey E Olgin
- Division of Cardiology, Electrophysiology and Arrhythmia Service, University of California, San Francisco. 500 Parnassus Avenue, Box 1354, MU 429, San Francisco, CA 94143-1354, United States.
| | - Byron K Lee
- Division of Cardiology, Electrophysiology and Arrhythmia Service, University of California, San Francisco. 500 Parnassus Avenue, Box 1354, MU 429, San Francisco, CA 94143-1354, United States.
| |
Collapse
|
21
|
Pedersen SS, Carter N, Barr C, Scholten M, Lambiase PD, Boersma L, Johansen JB, Theuns DAMJ. Quality of life, depression, and anxiety in patients with a subcutaneous versus transvenous defibrillator system. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2019; 42:1541-1551. [PMID: 31677279 DOI: 10.1111/pace.13828] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 10/11/2019] [Accepted: 10/30/2019] [Indexed: 12/14/2022]
Abstract
BACKGROUND Use of the subcutaneous implantable defibrillator (S-ICD) has increased because the device received US Food and Drug Administration approval in 2012, but we still know little about whether the quality of life (QoL) of patients with an S-ICD versus a transvenous ICD (TV-ICD) is comparable. We compared S-ICD patients with TV-ICD patients on QoL, depression, and anxiety up to 12 months' follow-up. METHODS A matched cohort of S-ICD (N = 167) and TV-ICD patients (N = 167) completed measures on QoL, depression, anxiety, and personality at baseline, 3, 6, and 12 months post implant. Data were analyzed using multivariable modeling with repeated measures. RESULTS In adjusted analyses, we found no statistically significant differences between cohorts on physical and mental QoL and depression (all Ps > .05), while S-ICD patients reported lower anxiety than TV-ICD patients (P = 0.0007). Both cohorts experienced improvements in physical and mental QoL and symptoms of depression and anxiety over time (all Ps < .001), primarily between implant and 3 months. These improvements were similar for both cohorts with respect to physical and mental QoL and anxiety (Ps > .05), while S-ICD patients experienced greater reductions in depressive symptoms (P = .0317). CONCLUSION The QoL and depression levels were similar in patients with an S-ICD and a TV-ICD up to 12 months' follow-up, while S-ICD patients reported lower anxiety levels and a greater reduction in depression over time as compared to TV-ICD patients. This knowledge may be important for patients and clinicians, if the indication for implantation allows both the S-ICD and the TV-ICD, making a choice possible.
Collapse
Affiliation(s)
- Susanne S Pedersen
- Department of Psychology, University of Southern Denmark, Odense, Denmark.,Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Craig Barr
- Department of Cardiology, Russels Hall Hospital, Dudley, UK
| | - Marcoen Scholten
- Department of Cardiology, Thorax Center Twente, Medisch Spectrum Twente, Enschede, The Netherlands
| | - Pier D Lambiase
- Institute of Cardiovascular Science, University College London & Barts Heart Centre, London, UK
| | | | | | | | -
- Department of Psychology, University of Southern Denmark, Odense, Denmark
| |
Collapse
|