1
|
Hare MM, Wohlgemuth KJ, Blue MNM, Mota JA. Reliability and Validity of Muscle Size and Quality Analysis Techniques. ULTRASOUND IN MEDICINE & BIOLOGY 2024:S0301-5629(24)00177-7. [PMID: 38697896 DOI: 10.1016/j.ultrasmedbio.2024.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 04/05/2024] [Accepted: 04/11/2024] [Indexed: 05/05/2024]
Abstract
OBJECTIVE This study investigated reliability and validity of muscle cross-sectional area and echo intensity using an automatic image analysis program. METHODS Twenty-two participants completed two data collection trials consisting of ultrasound imaging of the vastus lateralis (VL) at 10 and 12 MHz. Images were analyzed manually and with Deep Anatomical Cross-Sectional Area (DeepACSA). Reliability statistics (i.e., intraclass correlation coefficient [ICC] model 2,1, standard error of measure expressed as a percentage of the mean [SEM%], minimal differences [MD] values needed to be considered real) and validity statistics (i.e., constant error [CE], total error [TE], standard error of the estimate [SEE]) were calculated. RESULTS Automatic analyses of ACSA and EI demonstrated good reliability (10 MHz: ICC2,1 = 0.83 - 0.90; 12 MHz: ICC2,1 = 0.87-0.88), while manual analyses demonstrated moderate to excellent reliability (10 MHz: ICC2,1 = 0.82-0.99; 12 MHz: ICC2,1 = 0.73-0.99). Automatic analyses of ACSA presented greater error at 10 (CE = -0.76 cm2, TE = 4.94 cm2, SEE = 3.65 cm2) than 12 MHz (CE = 0.17 cm2, TE = 3.44 cm2, SEE = 3.11 cm2). Analyses of EI presented greater error at 10 (CE = 3.35 a.u., TE = 2.70 a.u., SEE = 2.58 a.u.) than at 12 MHz (CE = 3.21 a.u., TE = 2.61 a.u., SEE = 2.34 a.u.). CONCLUSION The results suggest the DeepACSA program may be less reliable compared to manual analysis for VL ACSA but displayed similar reliability for EI. In addition, the results demonstrated the automatic program had low error for 10 and 12 MHz.
Collapse
Affiliation(s)
- McKenzie M Hare
- Neuromuscular and Occupational Performance Laboratory, Texas Tech University, Lubbock, TX, USA
| | - Kealey J Wohlgemuth
- Neuromuscular and Occupational Performance Laboratory, Texas Tech University, Lubbock, TX, USA
| | - Malia N M Blue
- Health Exercise and Lifestyle Laboratory, University of North Carolina, Chapel Hill, NC, USA
| | - Jacob A Mota
- Neuromuscular and Occupational Performance Laboratory, Texas Tech University, Lubbock, TX, USA.
| |
Collapse
|
2
|
Andersen V, Paulsen G, Stien N, Baarholm M, Seynnes O, Saeterbakken AH. Resistance Training With Different Velocity Loss Thresholds Induce Similar Changes in Strength and Hypertrophy. J Strength Cond Res 2024; 38:e135-e142. [PMID: 34100789 DOI: 10.1519/jsc.0000000000004067] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
ABSTRACT Andersen, V, Paulsen, G, Stien, N, Baarholm, M, Seynnes, O, and Saeterbakken, AH. Resistance training with different velocity loss thresholds induce similar changes in strengh and hypertrophy. J Strength Cond Res 38(3): e135-e142, 2024-The aim of this study was to compare the effects of 2 velocity-based resistance training programs when performing resistance training with matched training volume. Ten resistance-trained adults volunteered (age, 23 ± 4.3 years; body mass, 68 ± 8.9 kg; and height, 171 ± 8 cm) with a mean resistance training experience of 4.5 years. A within person, between leg design was used. For each subject, the legs were randomly assigned to either low velocity loss (LVL) threshold at 15% or high velocity loss (HVL) threshold at 30% velocity loss. Leg press and leg extension were trained unilaterally twice per week over a period of 9 weeks. Before and after the intervention, both legs were tested in 1 repetition maximum (RM) (kg), maximal voluntary contraction (MVC) (N), rate of force development (N·s -1 ), average velocity (m·s -1 ), and power output (W) at 30, 45, 60, and 75% of 1 RM (all in unilateral leg press). Furthermore, muscle thickness (mm) of the vastus lateralis and rectus femoris, pennation angle (°) of the vastus lateralis, and the fascicle length (mm) of the vastus lateralis were measured using ultrasound imaging. The data were analyzed using mixed-design analysis of variance. No differences between the legs in any of the variables were found; however, both low and HVL were effective for increasing 1 RM (ES = 1.25-1.82), MVC (effect size [ES] = 0.42-0.64), power output (ES = 0.31-0.86), and muscle thickness (ES = 0.24-0.51). In conclusion, performing velocity-based resistance training with low and HVL with equal training volume resulted in similar effects in maximal and explosive strength in addition to muscular adaptations.
Collapse
Affiliation(s)
- Vidar Andersen
- Faculty of Education, Arts and Sports, Western Norway University of Applied Sciences, Sogndal, Norway; and
| | - Gøran Paulsen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Nicolay Stien
- Faculty of Education, Arts and Sports, Western Norway University of Applied Sciences, Sogndal, Norway; and
| | - Martin Baarholm
- Faculty of Education, Arts and Sports, Western Norway University of Applied Sciences, Sogndal, Norway; and
| | - Olivier Seynnes
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Atle Hole Saeterbakken
- Faculty of Education, Arts and Sports, Western Norway University of Applied Sciences, Sogndal, Norway; and
| |
Collapse
|
3
|
Hoeffner R, Agergaard AS, Svensson RB, Cullum C, Mikkelsen RK, Konradsen L, Krogsgaard M, Boesen M, Kjaer M, Magnusson SP. Tendon Elongation and Function After Delayed or Standard Loading of Surgically Repaired Achilles Tendon Ruptures: A Randomized Controlled Trial. Am J Sports Med 2024; 52:1022-1031. [PMID: 38353060 DOI: 10.1177/03635465241227178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
BACKGROUND Achilles tendon ruptures often result in long-term functional deficits despite accelerated (standard) rehabilitation. PURPOSE/HYPOTHESIS The purpose of this study was to investigate if delayed loading would influence functional, clinical, and structural outcomes of the muscles and tendon 1 year after a surgical repair. It was hypothesized that delaying the loading would reduce the heel-rise height deficit 1 year after Achilles tendon rupture. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS In total, 48 patients with a surgically repaired Achilles tendon rupture were randomized to 2 groups: the standard group received the currently accepted rehabilitation, and the delayed group received the same rehabilitation except that initial loading was delayed by 6 weeks. The primary outcome was the heel-rise height difference between the injured and uninjured sides at 1 year. The secondary outcomes were (1) tendon length measured with magnetic resonance imaging, (2) muscle fascicle length and pennation angle of the gastrocnemius medialis muscle, (3) Doppler activity measured with ultrasonography, (4) Achilles tendon Total Rupture Score (ATRS), and (5) isometric muscle strength. RESULTS The mean heel-rise height deficits for the standard and delayed groups were -2.2 cm and -2.1 cm, respectively (P = .719). The soleus part of the tendon was already elongated 1 week after surgery in both groups without a between-group difference (side-to-side difference: standard, 16.3 mm; delayed, 17.5 mm; P = .997) and did not change over 52 weeks. The gastrocnemius tendon length was unchanged at 1 week but elongated over time without a between-group difference (side-to-side difference at 52 weeks: standard, 10.5 mm; delayed, 13.0 mm; P = .899). The delayed group had less Doppler activity at 12 weeks (P = .006) and a better ATRS (standard, 60 points; delayed, 72 points; P = .032) at 52 weeks. CONCLUSION Delayed loading was not superior to standard loading in reducing the heel-rise height difference at 1 year. The data indirectly suggested reduced inflammation in the initial months and a better patient-reported outcome at 1 year in the delayed group. The soleus part of the tendon was already markedly elongated (35%) 1 week after surgery, while the length of the gastrocnemius tendon was unchanged at 1 week but was 6% elongated at 1 year. Together, these data indirectly suggest that the delayed group fared better, although this finding needs to be confirmed in future investigations. REGISTRATION NCT04263493 (ClinicalTrials.gov identifier).
Collapse
Affiliation(s)
- Rikke Hoeffner
- Institute of Sports Medicine Copenhagen, Department of Orthopaedic Surgery, University Hospital Bispebjerg-Frederiksberg, Copenhagen, Denmark
- Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Physical and Occupational Therapy, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Anne-Sofie Agergaard
- Institute of Sports Medicine Copenhagen, Department of Orthopaedic Surgery, University Hospital Bispebjerg-Frederiksberg, Copenhagen, Denmark
- Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Physical and Occupational Therapy, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Rene B Svensson
- Institute of Sports Medicine Copenhagen, Department of Orthopaedic Surgery, University Hospital Bispebjerg-Frederiksberg, Copenhagen, Denmark
- Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Camilla Cullum
- Department of Physical and Occupational Therapy, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Rasmus Kramer Mikkelsen
- Section for Sports Traumatology, Department of Orthopedic Surgery, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Lars Konradsen
- Section for Sports Traumatology, Department of Orthopedic Surgery, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Michael Krogsgaard
- Section for Sports Traumatology, Department of Orthopedic Surgery, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Mikael Boesen
- Department of Radiology, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| | - Michael Kjaer
- Institute of Sports Medicine Copenhagen, Department of Orthopaedic Surgery, University Hospital Bispebjerg-Frederiksberg, Copenhagen, Denmark
- Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - S Peter Magnusson
- Institute of Sports Medicine Copenhagen, Department of Orthopaedic Surgery, University Hospital Bispebjerg-Frederiksberg, Copenhagen, Denmark
- Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Physical and Occupational Therapy, University Hospital Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark
| |
Collapse
|
4
|
Beausejour JP, Knowles KS, Wilson AT, Mangum LC, Hill EC, Hanney WJ, Wells AJ, Fukuda DH, Stout J, Stock MS. Innovations in the Assessment of Skeletal Muscle Health: A Glimpse into the Future. Int J Sports Med 2024. [PMID: 38198822 DOI: 10.1055/a-2242-3226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
Skeletal muscle is the largest organ system in the human body and plays critical roles in athletic performance, mobility, and disease pathogenesis. Despite growing recognition of its importance by major health organizations, significant knowledge gaps remain regarding skeletal muscle health and its crosstalk with nearly every physiological system. Relevant public health challenges like pain, injury, obesity, and sarcopenia underscore the need to accurately assess skeletal muscle health and function. Feasible, non-invasive techniques that reliably evaluate metrics including muscle pain, dynamic structure, contractility, circulatory function, body composition, and emerging biomarkers are imperative to unraveling the complexities of skeletal muscle. Our concise review highlights innovative or overlooked approaches for comprehensively assessing skeletal muscle in vivo. We summarize recent advances in leveraging dynamic ultrasound imaging, muscle echogenicity, tensiomyography, blood flow restriction protocols, molecular techniques, body composition, and pain assessments to gain novel insight into muscle physiology from cellular to whole-body perspectives. Continued development of precise, non-invasive tools to investigate skeletal muscle are critical in informing impactful discoveries in exercise and rehabilitation science.
Collapse
Affiliation(s)
- Jonathan P Beausejour
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - Kevan S Knowles
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - Abigail T Wilson
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - L Colby Mangum
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - Ethan C Hill
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - William J Hanney
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - Adam J Wells
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - David H Fukuda
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - JeffreyR Stout
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| | - Matt S Stock
- Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, United States
| |
Collapse
|
5
|
Ritsche P, Franchi MV, Faude O, Finni T, Seynnes O, Cronin NJ. Fully Automated Analysis of Muscle Architecture from B-Mode Ultrasound Images with DL_Track_US. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:258-267. [PMID: 38007322 DOI: 10.1016/j.ultrasmedbio.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 10/25/2023] [Accepted: 10/26/2023] [Indexed: 11/27/2023]
Abstract
OBJECTIVE B-mode ultrasound can be used to image musculoskeletal tissues, but one major bottleneck is analyses of muscle architectural parameters (i.e., muscle thickness, pennation angle and fascicle length), which are most often performed manually. METHODS In this study we trained two different neural networks (classic U-Net and U-Net with VGG16 pre-trained encoder) to detect muscle fascicles and aponeuroses using a set of labeled musculoskeletal ultrasound images. We determined the best-performing model based on intersection over union and loss metrics. We then compared neural network predictions on an unseen test set with those obtained via manual analysis and two existing semi/automated analysis approaches (simple muscle architecture analysis [SMA] and UltraTrack). DL_Track_US detects the locations of the superficial and deep aponeuroses, as well as multiple fascicle fragments per image. RESULTS For single images, DL_Track_US yielded results similar to those produced by a non-trainable automated method (SMA; mean difference in fascicle length: 5.1 mm) and human manual analysis (mean difference: -2.4 mm). Between-method differences in pennation angle were within 1.5°, and mean differences in muscle thickness were less than 1 mm. Similarly, for videos, there was overlap between the results produced with UltraTrack and DL_Track_US, with intraclass correlations ranging between 0.19 and 0.88. CONCLUSION DL_Track_US is fully automated and open source and can estimate fascicle length, pennation angle and muscle thickness from single images or videos, as well as from multiple superficial muscles. We also provide a user interface and all necessary code and training data for custom model development.
Collapse
Affiliation(s)
- Paul Ritsche
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland.
| | - Martino V Franchi
- Department of Biomedical Sciences, University of Padova, Padova, Italy
| | - Oliver Faude
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| | - Taija Finni
- Faculty of Sport and Health Sciences, University of Jyvaskyla, Jyvaskyla, Finland
| | - Olivier Seynnes
- Department for Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Neil J Cronin
- Faculty of Sport and Health Sciences, University of Jyvaskyla, Jyvaskyla, Finland; School of Sport & Exercise, University of Gloucestershire, Gloucester, UK
| |
Collapse
|
6
|
Kilpatrick H, Bush E, Lockard C, Zhou X, Coolbaugh C, Damon B. Quantitative Muscle Fascicle Tractography Using Brightness-Mode Ultrasound. J Appl Biomech 2023; 39:421-431. [PMID: 37793655 DOI: 10.1123/jab.2022-0270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 06/01/2023] [Accepted: 07/17/2023] [Indexed: 10/06/2023]
Abstract
A muscle's architecture, defined as the geometric arrangement of its fibers with respect to its mechanical line of action, impacts its abilities to produce force and shorten or lengthen under load. Ultrasound and other noninvasive imaging methods have contributed significantly to our understanding of these structure-function relationships. The goal of this work was to develop a MATLAB toolbox for tracking and mathematically representing muscle architecture at the fascicle scale, based on brightness-mode ultrasound imaging data. The MuscleUS_Toolbox allows user-performed segmentation of a region of interest and automated modeling of local fascicle orientation; calculation of streamlines between aponeuroses of origin and insertion; and quantification of fascicle length, pennation angle, and curvature. A method is described for optimizing the fascicle orientation modeling process, and the capabilities of the toolbox for quantifying and visualizing fascicle architecture are illustrated in the human tibialis anterior muscle. The toolbox is freely available.
Collapse
Affiliation(s)
- Hannah Kilpatrick
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Emily Bush
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Carly Lockard
- Carle Clinical Imaging Research Program, Stephens Family Clinical Research Institute, Carle Health, Urbana, IL, USA
| | - Xingyu Zhou
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
- Carle Clinical Imaging Research Program, Stephens Family Clinical Research Institute, Carle Health, Urbana, IL, USA
| | - Crystal Coolbaugh
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Bruce Damon
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
- Carle Clinical Imaging Research Program, Stephens Family Clinical Research Institute, Carle Health, Urbana, IL, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| |
Collapse
|
7
|
Pincheira PA, Mayfield DL, Fox AS, Brown NAT, Carroll TJ, Cresswell AG, Lichtwark GA. Increased muscle force does not induce greater stretch-induced damage to calf muscles during work-matched heel drop exercise. Eur J Appl Physiol 2023; 123:1801-1808. [PMID: 37055644 PMCID: PMC10363059 DOI: 10.1007/s00421-023-05188-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 03/22/2023] [Indexed: 04/15/2023]
Abstract
PURPOSE To investigate the effect of muscle force during active stretch on quantitative and qualitative indicators of exercise-induced muscle damage (EIMD) in the medial gastrocnemius (MG) muscle. METHODS Twelve recreationally active volunteers performed two trials of an eccentric heel drop exercise. Participants performed a single bout of low-load (body weight) and high-load (body weight + 30% body weight) exercises on separate legs. The total mechanical work output for each condition was matched between legs. Before, two hours and 48 h after each bout of eccentric exercise, electrically stimulated triceps surae twitch torque, muscle soreness, MG active fascicle length at maximum twitch torque and muscle passive stiffness were collected. Triceps surae electromyographic (EMG) activity, MG fascicle stretch and MG muscle-tendon unit (MTU) length were measured during the eccentric tasks. RESULTS The high-load condition increased triceps surae muscle activity by 6-9%, but reduced MG fascicle stretch (p < 0.001). MTU stretch was similar between conditions. The greater muscle force during stretch did not give rise to additional torque loss (5 vs 6%) or intensify muscle soreness. CONCLUSIONS Adding 30% body weight during eccentric contractions has a modest impact on exercise-induced muscle damage in the medial gastrocnemius muscle. These results suggest that muscle load may not be an important determinant of stretch-induced muscle damage in the human MG muscle. The muscle investigated does exhibit large pennation angles and high series elastic compliance; architectural features that likely buffer muscle fibres against stretch and damage.
Collapse
Affiliation(s)
- Patricio A Pincheira
- School of Human Movement and Nutrition Sciences, The University of Queensland, Blair Drive 26B, St Lucia, Brisbane, 4067, Australia.
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia.
| | - Dean L Mayfield
- Department of Evolution, Ecology, and Organismal Biology, University of California, Riverside, USA
| | - Aaron S Fox
- Centre for Sport Research, School of Exercise and Nutrition Sciences, Deakin University, Geelong, Australia
| | | | - Timothy J Carroll
- School of Human Movement and Nutrition Sciences, The University of Queensland, Blair Drive 26B, St Lucia, Brisbane, 4067, Australia
| | - Andrew G Cresswell
- School of Human Movement and Nutrition Sciences, The University of Queensland, Blair Drive 26B, St Lucia, Brisbane, 4067, Australia
| | - Glen A Lichtwark
- School of Human Movement and Nutrition Sciences, The University of Queensland, Blair Drive 26B, St Lucia, Brisbane, 4067, Australia
| |
Collapse
|
8
|
Quinlan JI, Dhaliwal A, Williams FR, Allen SL, Choudhary S, Rowlands A, Breen L, Lavery GG, Lord JM, Elsharkawy AM, Armstrong MJ, Greig CA. Impaired lower limb muscle mass, quality and function in end stage liver disease: A cross-sectional study. Exp Physiol 2023; 108:1066-1079. [PMID: 37166422 PMCID: PMC10988432 DOI: 10.1113/ep091157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 04/26/2023] [Indexed: 05/12/2023]
Abstract
NEW FINDINGS What is the central question of this study? To what extent does musculoskeletal impairment occur (i.e., muscle mass, quality and function) in patients with end stage liver disease (ESLD) by comparison to a healthy age/sex-matched control group? What is the main finding and its importance? Muscle mass, quality and function are impaired in patients with ESLD (compared to age/sex matched controls). Importantly, greater impairments were seen in lower limb compared to arm and trunk muscle groups. These findings may suggest that there should be greater consideration of muscle health in functionally relevant lower limb muscle groups. ABSTRACT Sarcopenia is associated with reduced quality of life and increased mortality in patients with end stage liver disease (ESLD). Historically, sarcopenia identification in ESLD utilised L3 skeletal muscle index (SMI). There are few data on muscle quality and function within lower limb muscle groups with high functional relevance. The aim of this prospective case-control study was to evaluate the quadriceps muscle in patients with ESLD. Muscle mass and quality were evaluated using MRI (quadriceps anatomical cross sectional area (ACSA), quadriceps volume index, L3 SMI, quadriceps intermuscular adipose tissue (IMAT)), mid-arm muscle circumference (MAMC) and ultrasonography (vastus lateralis (VL) thickness and quadriceps ACSA). Muscle strength/function was assessed by handgrip strength, peak quadriceps isokinetic torque and chair rise time. Thirty-nine patients with ESLD (55 years, 61% male, 48% alcoholic related liver disease (ArLD), 71% Child-Pugh B/C) and 18 age/sex-matched healthy control participants (HC) were studied. Quadriceps mass was significantly reduced in ESLD versus HC (-17%), but L3 SMI and MAMC were unchanged. Quadriceps IMAT percentage was increased in ESLD (+103%). Handgrip strength (-15%), peak isokinetic torque (-29%), and chair rise time (+56%) were impaired in ESLD. Ultrasound measures of VL thickness (r = 0.56, r = 0.57, r = 0.42) and quadriceps ACSA (r = 0.98, r = 0.86, r = 0.67) correlated to MRI quadriceps ACSA, quadriceps volume and L3 SMI, respectively. Quadriceps muscle mass, quality, and function were impaired in patients with ESLD, whereas conventional assessments of muscle (L3 SMI and MAMC) highlighted no differences between ESLD and HC. Full evaluation of lower limb muscle health is essential in ESLD in order to accurately assess sarcopenia and target future interventions.
Collapse
Affiliation(s)
- Jonathan I. Quinlan
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- School of Sport, Exercise and Rehabilitation SciencesUniversity of BirminghamBirminghamUK
| | - Amritpal Dhaliwal
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- Institute of Inflammation and AgeingUniversity of BirminghamBirminghamUK
| | - Felicity R. Williams
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- Institute of Inflammation and AgeingUniversity of BirminghamBirminghamUK
- Therapies DepartmentUniversity Hospitals BirminghamBirminghamUK
| | - Sophie L. Allen
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- School of Sport, Exercise and Rehabilitation SciencesUniversity of BirminghamBirminghamUK
| | | | - Alex Rowlands
- NIHR Leicester Biomedical Research CentreLeicesterUK
- Diabetes Research CentreUniversity of Leicester, Leicester General HospitalLeicesterUK
| | - Leigh Breen
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- School of Sport, Exercise and Rehabilitation SciencesUniversity of BirminghamBirminghamUK
- MRC‐Versus Arthritis Centre for Musculoskeletal Ageing ResearchUniversity of BirminghamBirminghamUK
| | - Gareth G. Lavery
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- MRC‐Versus Arthritis Centre for Musculoskeletal Ageing ResearchUniversity of BirminghamBirminghamUK
- Department of BiosciencesNottingham Trent UniversityNottinghamUK
| | - Janet M. Lord
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- Institute of Inflammation and AgeingUniversity of BirminghamBirminghamUK
- MRC‐Versus Arthritis Centre for Musculoskeletal Ageing ResearchUniversity of BirminghamBirminghamUK
| | - Ahmed M. Elsharkawy
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- Liver UnitQueen Elizabeth Hospital BirminghamBirminghamUK
| | - Matthew J. Armstrong
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- Liver UnitQueen Elizabeth Hospital BirminghamBirminghamUK
| | - Carolyn A. Greig
- NIHR Birmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation Trust and University of BirminghamBirminghamUK
- School of Sport, Exercise and Rehabilitation SciencesUniversity of BirminghamBirminghamUK
- MRC‐Versus Arthritis Centre for Musculoskeletal Ageing ResearchUniversity of BirminghamBirminghamUK
| |
Collapse
|
9
|
Macías-Valle A, Rodríguez-López C, González-Senac NM, Mayordomo-Cava J, Vidán MT, Cruz-Arnés ML, Jiménez-Gómez LM, Dujovne-Lindenbaum P, Pérez-Menéndez ME, Ortiz-Alonso J, Valenzuela PL, Rodríguez-Romo G, Serra-Rexach JA. Exercise effects on functional capacity and quality of life in older patients with colorectal cancer: study protocol for the ECOOL randomized controlled trial. BMC Geriatr 2023; 23:314. [PMID: 37211611 DOI: 10.1186/s12877-023-04026-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 05/08/2023] [Indexed: 05/23/2023] Open
Abstract
BACKGROUND Surgery and treatment for colorectal cancer (CRC) in the elderly patient increase the risk of developing post-operative complications, losing functional independence, and worsening health-related quality of life (HRQoL). There is a lack of high-quality randomized controlled trials evaluating the potential benefit of exercise as a countermeasure. The primary aim of this study is to evaluate the effectiveness of a home-based multicomponent exercise program for improving HRQoL and functional capacity in older adults undergoing CRC surgery and treatment. METHODS This randomized, controlled, observer-blinded, single-center trial aims to randomize 250 patients (>74 years) to either an intervention or a control group (i.e., usual care). The intervention group will perform an individualized home-based multicomponent exercise program with weekly telephone supervision from diagnosis until three months post-surgery. The primary outcomes will be HRQoL (EORTC QLQ-C30; CR29; and ELD14) and functional capacity (Barthel Index and Short Physical Performance Battery), which will be assessed at diagnosis, at discharge, and one, three, and six months after surgery. Secondary outcomes will be frailty, physical fitness, physical activity, inspiratory muscle function, sarcopenia and cachexia, anxiety and depression, ambulation ability, surgical complications, and hospital length of stay, readmission and mortality. DISCUSSION This study will examine the effects of an exercise program in older patients with CRC across a range of health-related outcomes. Expected findings are improvement in HRQoL and physical functioning. If proven effective, this simple exercise program may be applied in clinical practice to improve CRC care in older patients. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT05448846.
Collapse
Affiliation(s)
- Angela Macías-Valle
- Faculty of Physical Activity and Sport Sciences (INEF), Universidad Politécnica de Madrid, Madrid, Spain
| | - Carlos Rodríguez-López
- Centro de Investigación Biomédica en Red de Fragilidad y Envejecimiento Saludable (CIBERFES), Madrid, Spain.
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain.
| | - Nicolas María González-Senac
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain
| | - Jennifer Mayordomo-Cava
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain
| | - María Teresa Vidán
- Centro de Investigación Biomédica en Red de Fragilidad y Envejecimiento Saludable (CIBERFES), Madrid, Spain
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain
- School of Medicine, Department of Medicine, Universidad Complutense, Madrid, Spain
| | - María Luisa Cruz-Arnés
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain
| | - Luis Miguel Jiménez-Gómez
- Colorectal Surgery Unit - General Surgery Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Paula Dujovne-Lindenbaum
- Colorectal Surgery Unit - General Surgery Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Maria Elena Pérez-Menéndez
- Colorectal Surgery Unit - General Surgery Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Javier Ortiz-Alonso
- Centro de Investigación Biomédica en Red de Fragilidad y Envejecimiento Saludable (CIBERFES), Madrid, Spain
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain
- School of Medicine, Department of Medicine, Universidad Complutense, Madrid, Spain
| | - Pedro L Valenzuela
- Physical Activity and Health Research Group (PaHerg), Research Institute of the Hospital Universitario 12 de Octubre ("Imas12"), Madrid, Spain
| | - Gabriel Rodríguez-Romo
- Faculty of Physical Activity and Sport Sciences (INEF), Universidad Politécnica de Madrid, Madrid, Spain
- Centro de Investigación Biomédica en Red de Fragilidad y Envejecimiento Saludable (CIBERFES), Madrid, Spain
| | - Jose Antonio Serra-Rexach
- Centro de Investigación Biomédica en Red de Fragilidad y Envejecimiento Saludable (CIBERFES), Madrid, Spain
- Department of Geriatrics, Hospital General Universitario Gregorio Marañón. Health Research Institute Gregorio Marañón (IiSGM), Dr.Esquerdo 46, 28007, Madrid, Spain
- School of Medicine, Department of Medicine, Universidad Complutense, Madrid, Spain
| |
Collapse
|
10
|
Bao X, Zhang Q, Fragnito N, Wang J, Sharma N. A clustering-based method for estimating pennation angle from B-mode ultrasound images. WEARABLE TECHNOLOGIES 2023; 4:e6. [PMID: 38487764 PMCID: PMC10936288 DOI: 10.1017/wtc.2022.30] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 08/08/2022] [Accepted: 11/25/2022] [Indexed: 03/17/2024]
Abstract
B-mode ultrasound (US) is often used to noninvasively measure skeletal muscle architecture, which contains human intent information. Extracted features from B-mode images can help improve closed-loop human-robotic interaction control when using rehabilitation/assistive devices. The traditional manual approach to inferring the muscle structural features from US images is laborious, time-consuming, and subjective among different investigators. This paper proposes a clustering-based detection method that can mimic a well-trained human expert in identifying fascicle and aponeurosis and, therefore, compute the pennation angle. The clustering-based architecture assumes that muscle fibers have tubular characteristics. It is robust for low-frequency image streams. We compared the proposed algorithm to two mature benchmark techniques: UltraTrack and ImageJ. The performance of the proposed approach showed higher accuracy in our dataset (frame frequency is 20 Hz), that is, similar to the human expert. The proposed method shows promising potential in automatic muscle fascicle orientation detection to facilitate implementations in biomechanics modeling, rehabilitation robot control design, and neuromuscular disease diagnosis with low-frequency data stream.
Collapse
Affiliation(s)
- Xuefeng Bao
- Department of Biomedical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA
| | - Qiang Zhang
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, USA
- Joint Department of Biomedical Engineering, The University of North Carolina, Chapel Hill, NC, USA
| | - Natalie Fragnito
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, USA
- Joint Department of Biomedical Engineering, The University of North Carolina, Chapel Hill, NC, USA
| | | | - Nitin Sharma
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, USA
- Joint Department of Biomedical Engineering, The University of North Carolina, Chapel Hill, NC, USA
| |
Collapse
|
11
|
Directionality quantification of in vitro grown dorsal root ganglion neurites using Fast Fourier Transform. J Neurosci Methods 2023; 386:109796. [PMID: 36652975 DOI: 10.1016/j.jneumeth.2023.109796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 12/22/2022] [Accepted: 01/13/2023] [Indexed: 01/16/2023]
Abstract
BACKGROUND The directionality analysis of the neurite outgrowths is an important methodology in neuroscience, especially in determining the behavior of neurons grown on silicon substrates. NEW METHOD Here we aimed to describe the methodology for quantification of the directionality of neurites based on the Fast Fourier Transform (FFT). We performed an image analysis case study that incorporates several software solutions and provides a rapid and precise technique to determine the directionality of neurites. In order to elicit aligned or unaligned neurite growth patterns, we used adult and newborn dorsal root ganglion (DRG) neurons grown on silicon micro-pillar substrates (MPS) with different pillar widths and spacing. RESULTS Compared to the control glass surfaces the neonatal and adult N52 and IB4 DRG neurites exhibited regular growth patterns more pronounced in the MPS regions with s narrow pillar spacing range. The neurites were preferentially oriented along three directional axes at 30°, 90°, and 150°. CONCLUSION The proposed methodology showed that FFT analysis is a reliable and easily reproducible method that can be successfully used to test growth patterns of DRG neurites grown on different substrates by considering the direction and angle of the neurites as well as the size of the soma.
Collapse
|
12
|
Vo MHT, Lin CJ, Chieh HF, Kuo LC, An KN, Wang YL, Su FC. Behavior of medial gastrocnemius muscle beneath kinesio taping during isometric contraction and badminton lunge performance after fatigue induction. Sci Rep 2023; 13:1779. [PMID: 36720990 PMCID: PMC9889375 DOI: 10.1038/s41598-023-28818-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 01/25/2023] [Indexed: 02/02/2023] Open
Abstract
Kinesio taping (KT) is widely used in sports for performance improvement and injury prevention. However, little is known of the behavior of the muscle region beneath the KT with movement, particularly when the muscle is fatigued. Accordingly, this study investigated the changes in the medial gastrocnemius muscle architecture and fascia thickness when using KT during maximum isometric plantar flexion (MVIC) and badminton lunges following heel rise exercises performed to exhaustion. Eleven healthy collegiate badminton players (4 males and 7 females) were recruited. All of the participants performed two tasks (MVIC and badminton lunge) with a randomized sequence of no taping, KT and sham taping and repeated following exhaustive repetitive heel rise exercise. In the MVIC task, the fascia thickness with the medial gastrocnemius muscle at rest significantly decreased following fatigue induction both without taping and with KT and sham taping (p = 0.036, p = 0.028 and p = 0.025, respectively). In the lunge task, the fascia thickness reduced after fatigue induction in the no taping and sham taping trials; however, no significant change in the fascia thickness occurred in the KT trials. Overall, the results indicate that KT provides a better effect during dynamic movement than in isometric contraction.
Collapse
Affiliation(s)
- Minh Hoang-Thuc Vo
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chien-Ju Lin
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Hsiao-Feng Chieh
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Li-Chieh Kuo
- Department of Occupational Therapy, National Cheng Kung University, Tainan, Taiwan
| | - Kai-Nan An
- Division of Orthopedic Research, Mayo Clinic, Rochester, USA
| | - Yu-Lin Wang
- Department of Rehabilitation, Chi Mei Medical Center, Tainan, Taiwan
| | - Fong-Chin Su
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
| |
Collapse
|
13
|
Werkhausen A, Gløersen Ø, Nordez A, Paulsen G, Bojsen-Møller J, Seynnes OR. Linking muscle architecture and function in vivo: conceptual or methodological limitations? PeerJ 2023; 11:e15194. [PMID: 37077309 PMCID: PMC10108853 DOI: 10.7717/peerj.15194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 03/15/2023] [Indexed: 04/21/2023] Open
Abstract
Background Despite the clear theoretical link between sarcomere arrangement and force production, the relationship between muscle architecture and function remain ambiguous in vivo. Methods We used two frequently used ultrasound-based approaches to assess the relationships between vastus lateralis architecture parameters obtained in three common conditions of muscle lengths and contractile states, and the mechanical output of the muscle in twenty-one healthy subjects. The relationship between outcomes obtained in different conditions were also examined. Muscle architecture was analysed in panoramic ultrasound scans at rest with the knee fully extended and in regular scans at an angle close to maximum force (60°), at rest and under maximum contraction. Isokinetic and isometric strength tests were used to estimate muscle force production at various fascicle velocities. Results Measurements of fascicle length, pennation angle and thickness obtained under different experimental conditions correlated moderately with each other (r = 0.40-.74). Fascicle length measured at 60° at rest correlated with force during high-velocity knee extension (r = 0.46 at 400° s-1) and joint work during isokinetic knee extension (r = 0.44 at 200° s-1 and r = 0.57 at 100° s-1). Muscle thickness was related to maximum force for all measurement methods (r = 0.44-0.73). However, we found no significant correlations between fascicle length or pennation angle and any measures of muscle force or work. Most correlations between architecture and force were stronger when architecture was measured at rest close to optimal length. Conclusion These findings reflect methodological limitations of current approaches to measure fascicle length and pennation angle in vivo. They also highlight the limited value of static architecture measurements when reported in isolation or without direct experimental context.
Collapse
Affiliation(s)
- Amelie Werkhausen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Øyvind Gløersen
- Smart Sensors and Microsystems, SINTEF Digital, Oslo, Norway
| | - Antoine Nordez
- Movement - Interactions - Performance, MIP, Nantes Université, Nantes, France
- Institut Universitaire de France, IUF, France
| | - Gøran Paulsen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Jens Bojsen-Møller
- Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark
| | - Olivier R. Seynnes
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| |
Collapse
|
14
|
Ritsche P, Schmid R, Franchi MV, Faude O. Agreement and reliability of lower limb muscle architecture measurements using a portable ultrasound device. Front Physiol 2022; 13:981862. [PMID: 36117694 PMCID: PMC9478722 DOI: 10.3389/fphys.2022.981862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 08/10/2022] [Indexed: 11/13/2022] Open
Abstract
High end ultrasonography devices lack in portability and are expensive. We investigated the agreement and reliability of a handheld and portable ultrasound system for human lower limb muscle architecture measurements. We captured ultrasound images of the rectus femoris (RF), vastus lateralis (VL) and gastrocnemius medialis (GM) in 36 active healthy participants (15 female, 21 male) at 50% of muscle length using the handheld Lumify (L12-4, linear-array 37 mm, Philips Healthcare, Amsterdam, Netherlands) and a high-end laboratory device (ACUSON Juniper, linear-array 54 mm, 12L3, SIEMENS Healthineers, Erlangen, Germany). We compared measurements of muscle fascicle length, pennation angle and thickness. To assess inter-session reliability of the Lumify system, participants were measured twice within 1 week. Comparing RF architecture measurements of both devices resulted in intra-class correlations (ICCs) ranging from 0.46–0.82 and standardized mean difference (SMDs) ranging from −0.45–0.05. For VL, ICCs ranged from 0.60–0.89 and SMDs ranged from −0.11–0.13. ICCs and SMDs for the GM ranged from 0.82–0.86 and −0.07–0.07. Calculating inter-session reliability for RF resulted in ICCs ranging from 0.44–0.76 and SMDs ranging from −0.38–0.15. For VL, ICCs and SMDs ranged from 0.57–0.75 and −0.13–0.02. ICCs for GM ranged from 0.75–0.92 and SMDs ranged from −0.15–0.16. Measurement of muscle thickness demonstrated the highest agreement (ICC ≥0.82) and reliability (ICC ≥0.75) across all muscles. The Lumify system was comparable to a high-end device and reliable for GM measurements. However, agreement and reliability were lower for the RF and VL. Of all evaluated architectural parameters, muscle thickness exhibited highest agreement and reliability.
Collapse
Affiliation(s)
- Paul Ritsche
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
- *Correspondence: Paul Ritsche,
| | - Reto Schmid
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| | - Martino V. Franchi
- Department of Biomedical Sciences, University of Padova, Padua, Italy
- CIR-MYO Myology Center, University of Padova, Padua, Italy
| | - Oliver Faude
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| |
Collapse
|
15
|
Tennler J, Hahn D, Raiteri BJ. Medial gastrocnemius muscle-tendon unit ratios of young females and males. J Biomech 2022; 142:111261. [PMID: 36027634 DOI: 10.1016/j.jbiomech.2022.111261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/25/2022] [Accepted: 08/11/2022] [Indexed: 10/15/2022]
Abstract
A muscle's contractile element length relative to its muscle-tendon unit (MTU) length is a fundamental design feature affecting MTU function, with high (0.9) or low ratios (0.1) favouring either rapid or economical force production, respectively. Despite the importance for MTU function, little in vivo work has been done to understand contractile element-MTU length ratio variability between individuals and sexes. We therefore compared the medial gastrocnemius (MG) MTU ratios of thirteen females and eighteen males, and explored whether individual ratios could be predicted based on anatomical features. At the presumed tendon slack length ankle joint angle, lengths of MG's MTU, Achilles tendon, muscle belly and its muscle fascicles were measured from B-mode ultrasound images. Contractile element length was represented by the in-series muscle fascicle length (FL) and was calculated by multiplying FL by the cosine of fascicle angle. The mean ± standard deviation in-series FL-MTU length ratio was 0.09 ± 0.02 and ranged from 0.06 to 0.11, whereas the muscle belly length-MTU length ratio was 0.54 ± 0.38 and ranged from 0.47 to 0.60. Neither ratio was significantly different between females and males (p ≥ 0.116). In-series FL was not significantly correlated with MTU length (r = -0.115, p =.538), muscle belly length (r = 0.05, p =.788), or shank length (r = 0.169, p =.364), but MTU length was significantly correlated with muscle belly length (r = 0.641, p <.001), and shank length (r = 0.575, p =.001). A low in-series FL-MTU length ratio suggests that the MG of young, healthy individuals is specialised for energy-efficient stretch-shortening cycles. These findings provide useful inputs for the MTU actuator design of Hill-type models.
Collapse
Affiliation(s)
- Janina Tennler
- Ruhr University Bochum, Faculty of Sport Science, Human Movement Science, Germany.
| | - Daniel Hahn
- Ruhr University Bochum, Faculty of Sport Science, Human Movement Science, Germany; School of Human Movement and Nutrition Science, University of Queensland, Brisbane, Australia
| | - Brent J Raiteri
- Ruhr University Bochum, Faculty of Sport Science, Human Movement Science, Germany
| |
Collapse
|
16
|
Wohlgemuth KJ, Blue MN, Mota JA. Reliability and accuracy of ultrasound image analyses completed manually versus an automated tool. PeerJ 2022; 10:e13609. [PMID: 35729910 PMCID: PMC9206842 DOI: 10.7717/peerj.13609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 05/28/2022] [Indexed: 01/17/2023] Open
Abstract
Analysis of Brightness-mode ultrasound-captured fascicle angle (FA) and fascicle length (FL) can be completed manually with computer-based programs or by automated programs. Insufficient data exists regarding reliability and accuracy of automated tools. Therefore, the purpose of this study was to determine the test-retest reliability of automatic and manual ultrasound analyses, while determining accuracy of the automatic tool against the manual equivalent. Twenty-three participants (mean ± SD; age = 24 ± 4 years; height = 172.2 ± 10.5 cm; body mass = 73.1 ± 16.1 kg) completed one laboratory visit consisting of two trials where vastus lateralis muscle architecture was assessed with ultrasound. Images were taken at both lower (10 MHz) and higher frequency (12 MHz). Images were analyzed manually in an open-source imaging program and automatically using a separate open-source macro function. Test-retest reliability statistics were calculated for automatic and manual analyses. Accuracy was determined with validity statistics and were calculated for automatic analyses. The results show that manual ultrasound analyses for FA and FL for both lower and higher frequency displayed good reliability (ICC2,1 = 0.75-0.86). However, automatic ultrasound analyses for FA and FL revealed moderate reliability (ICC2,1 = 0.61-0.72) for the lower frequency images and poor reliability (ICC2,1 = 0.16-0.27) for higher frequency images. When assessed against manual techniques, automatic analyses presented greater total error (TE) and standard error of the estimate (SEE) for FA at lower frequency (constant error (CE) = -3.91°, TE = 5.57°, SEE = 3.45°) than higher (CE = -2.78°, TE = -4.54°, SEE = 2.45°). For FL, the higher frequency error (CE = 0.92 cm, TE = 2.12 cm, SEE = 1.15 cm) was similar to lower frequency error (CE = 1.98 cm, TE = 3.66 cm, SEE = 1.57 cm). The findings overall show that manual analyses had good reliability and low absolute error, while demonstrating the automated counterpart had poor to moderate reliability and large errors in analyses. These findings may be impactful as they highlight the good reliability and low error associated with manually analyzed ultrasound images and validate a novel automatic tool for analyzing ultrasound images. Future work should focus on improving reliability and decreasing error in automated image analysis tools. Automated tools are promising for the field as they eliminate biases between analysts and may be more time efficient than manual techniques.
Collapse
Affiliation(s)
- Kealey J. Wohlgemuth
- Department of Kinesiology, University of Alabama - Tuscaloosa, Tuscaloosa, AL, United States
| | - Malia N.M Blue
- Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States
| | - Jacob A. Mota
- Department of Kinesiology, University of Alabama - Tuscaloosa, Tuscaloosa, AL, United States
| |
Collapse
|
17
|
Lindberg K, Lohne-Seiler H, Fosstveit SH, Sibayan EE, Fjeller JS, Løvold S, Kolnes T, Vårvik FT, Berntsen S, Paulsen G, Seynnes O, Bjørnsen T. Effectiveness of individualized training based on force-velocity profiling on physical function in older men. Scand J Med Sci Sports 2022; 32:1013-1025. [PMID: 35305276 PMCID: PMC9313882 DOI: 10.1111/sms.14157] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 03/05/2022] [Accepted: 03/08/2022] [Indexed: 11/27/2022]
Abstract
The study aimed to investigate the effectiveness of an individualized power training program based on force–velocity (FV) profiling on physical function, muscle morphology, and neuromuscular adaptations in older men. Forty‐nine healthy men (68 ± 5 years) completed a 10‐week training period to enhance muscular power. They were randomized to either a generic power training group (GPT) or an individualized power training group (IPT). Unlike generic training, individualized training was based on low‐ or high‐resistance exercises, from an initial force–velocity profile. Lower‐limb FV profile was measured in a pneumatic leg‐press, and physical function was assessed as timed up‐and‐go time (TUG), sit‐to‐stand power, grip strength, and stair‐climbing time (loaded [20kg] and unloaded). Vastus lateralis morphology was measured with ultrasonography. Rate of force development (RFD) and rate of myoelectric activity (RMA) were measured during an isometric knee extension. The GPT group improved loaded stair‐climbing time (6.3 ± 3.8 vs. 2.3% ± 7.3%, p = 0.04) more than IPT. Both groups improved stair‐climbing time, sit to stand, and leg press power, grip strength, muscle thickness, pennation angle, fascicle length, and RMA from baseline (p < 0.05). Only GPT increased loaded stair‐climbing time and RFD (p < 0.05). An individualized power training program based on FV profiling did not improve physical function to a greater degree than generic power training. A generic power training approach combining both heavy and low loads might be advantageous through eliciting both force‐ and velocity‐related neuromuscular adaptions with a concomitant increase in muscular power and physical function in older men.
Collapse
Affiliation(s)
- Kolbjørn Lindberg
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Hilde Lohne-Seiler
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Sindre H Fosstveit
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Erlend E Sibayan
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Joachim S Fjeller
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Sondre Løvold
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Tommy Kolnes
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Fredrik T Vårvik
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Sveinung Berntsen
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| | - Gøran Paulsen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Olivier Seynnes
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Thomas Bjørnsen
- Department of Sport Science and Physical Education, University of Agder, Kristiansand, Norway
| |
Collapse
|
18
|
van der Zee TJ, Kuo AD. TimTrack: A drift-free algorithm for estimating geometric muscle features from ultrasound images. PLoS One 2022; 17:e0265752. [PMID: 35324967 PMCID: PMC8947026 DOI: 10.1371/journal.pone.0265752] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 03/07/2022] [Indexed: 11/27/2022] Open
Abstract
Ultrasound imaging is valuable for non-invasively estimating fascicle lengths and other features of pennate muscle, especially when performed computationally. Effective analysis techniques to date typically use optic flow to track displacements from image sequences, but are sensitive to integration drift for longer sequences. We here present an alternative algorithm that objectively estimates geometric features of pennate muscle from ultrasound images, without drift sensitivity. The algorithm identifies aponeuroses and estimates fascicle angles to derive fascicle lengths. Length estimates of human vastus lateralis and gastrocnemius fascicles in healthy subjects (N = 9 and N = 17 respectively) compared well (overall root-mean-square difference, RMSD = 0.52 cm) to manual estimates by independent observers (n = 3), with overall coefficient of multiple correlation (CMC) of 0.98. Our tests yielded accuracy (CMC, RMSD) and processing speed similar to or exceeding that of state-of-the-art algorithms. The algorithm requires minimal manual intervention and can optionally extrapolate fascicle lengths that extend beyond the image frame. It thus facilitates automated analysis of ultrasound images without drift.
Collapse
Affiliation(s)
- Tim J. van der Zee
- Biomedical Engineering Graduate Program, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
- * E-mail:
| | - Arthur D. Kuo
- Biomedical Engineering Graduate Program, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
19
|
Hernández-Belmonte A, Martínez-Cava A, Pallarés JG. Pectoralis Cross-Sectional Area can be Accurately Measured using Panoramic Ultrasound: A Validity and Repeatability Study. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:460-468. [PMID: 34857426 DOI: 10.1016/j.ultrasmedbio.2021.10.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 09/13/2021] [Accepted: 10/20/2021] [Indexed: 06/13/2023]
Abstract
The objective of the current study was to examine the validity and repeatability of panoramic ultrasound in evaluating the anatomical cross-sectional area (ACSA) of the pectoralis major. Specifically, we aimed to quantify the measurement errors generated during the image acquisition and analysis (repeatability), as well as when comparing with magnetic resonance imaging (MRI) (validity). Moreover, we aimed to analyze the influence of the operator's experience on these measurement errors. Both sides of the chest of 16 participants (n = 32) were included. Errors made by two operators (trained and novice) when measuring pectoralis major ACSA (50% of sternum-areola mammae distance) were examined. Acquisition errors included the comparison of two images acquired 5 min apart. Acquisition 1 was analyzed twice to quantify analysis errors. Thereafter, acquisition 1 was compared with MRI. Statistics include the standard error of measurement (SEM), expressed in absolute (cm2) and relative (%) terms as a coefficient of variation (CV), and the calculation of systematic bias. Errors made by the trained operator were lower than those made by the novice, especially during the image acquisition (SEM = 0.25 vs. 0.66 cm2, CV = 1.06 vs. 2.98%) and when compared with MRI (SEM = 0.27 vs. 1.90 cm2, CV = 1.13 vs. 8.16%). Furthermore, although both operators underestimated the ACSA, magnitude and variability [SD] of these errors were lower for the trained operator (bias = -0.19 [0.34] cm2) than for the novice (bias = -1.97 [2.59] cm2). Panoramic ultrasound is a valid and repeatable technique for measuring pectoralis major ACSA, especially when implemented by a trained operator.
Collapse
Affiliation(s)
| | - Alejandro Martínez-Cava
- Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, Murcia, Spain
| | - Jesús G Pallarés
- Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, Murcia, Spain.
| |
Collapse
|
20
|
Hamarsland H, Moen H, Skaar OJ, Jorang PW, Rødahl HS, Rønnestad BR. Equal-Volume Strength Training With Different Training Frequencies Induces Similar Muscle Hypertrophy and Strength Improvement in Trained Participants. Front Physiol 2022; 12:789403. [PMID: 35069251 PMCID: PMC8766679 DOI: 10.3389/fphys.2021.789403] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 12/03/2021] [Indexed: 11/16/2022] Open
Abstract
The main goal of the current study was to compare the effects of volume-equated training frequency on gains in muscle mass and strength. In addition, we aimed to investigate whether the effect of training frequency was affected by the complexity, concerning the degrees of freedom, of an exercise. Participants were randomized to a moderate training frequency group (two weekly sessions) or high training frequency group (four weekly sessions). Twenty-one participants (male: 11, female: 10, age: 25.9 ± 4.0) completed the 9-week whole-body progressive heavy resistance training intervention with moderate (n = 13) or high (n = 8) training frequency. Whole-body and regional changes in lean mass were measured using dual-energy x-ray absorptiometry, while the vastus lateralis thickness was measured by ultrasound. Changes in muscle strength were measured as one repetition maximum for squat, hack squat, bench press, and chest press. No differences between groups were observed for any of the measures of muscle growth or muscle strength. Muscle strength increased to a greater extent in hack squat and chest press than squat and bench press for both moderate (50 and 21% vs. 19 and 14%, respectively) and high-frequency groups (63 and 31% vs. 19 and 16%, respectively), with no differences between groups. These results suggest that training frequency is less decisive when weekly training volume is equated. Further, familiarity with an exercise seems to be of greater importance for strength adaptations than the complexity of the exercise.
Collapse
Affiliation(s)
- Håvard Hamarsland
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Hermann Moen
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Ole Johannes Skaar
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Preben Wahlstrøm Jorang
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Håvard Saeterøy Rødahl
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Bent R Rønnestad
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| |
Collapse
|
21
|
Zhang Q, Iyer A, Lambeth K, Kim K, Sharma N. Ultrasound Echogenicity as an Indicator of Muscle Fatigue during Functional Electrical Stimulation. SENSORS 2022; 22:s22010335. [PMID: 35009875 PMCID: PMC8749646 DOI: 10.3390/s22010335] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/10/2021] [Accepted: 12/31/2021] [Indexed: 12/02/2022]
Abstract
Functional electrical stimulation (FES) is a potential neurorehabilitative intervention to enable functional movements in persons with neurological conditions that cause mobility impairments. However, the quick onset of muscle fatigue during FES is a significant challenge for sustaining the desired functional movements for more extended periods. Therefore, a considerable interest still exists in the development of sensing techniques that reliably measure FES-induced muscle fatigue. This study proposes to use ultrasound (US) imaging-derived echogenicity signal as an indicator of FES-induced muscle fatigue. We hypothesized that the US-derived echogenicity signal is sensitive to FES-induced muscle fatigue under isometric and dynamic muscle contraction conditions. Eight non-disabled participants participated in the experiments, where FES electrodes were applied on their tibialis anterior (TA) muscles. During a fatigue protocol under either isometric and dynamic ankle dorsiflexion conditions, we synchronously collected the isometric dorsiflexion torque or dynamic dorsiflexion angle on the ankle joint, US echogenicity signals from TA muscle, and the applied stimulation intensity. The experimental results showed an exponential reduction in the US echogenicity relative change (ERC) as the fatigue progressed under the isometric (R2=0.891±0.081) and dynamic (R2=0.858±0.065) conditions. The experimental results also implied a strong linear relationship between US ERC and TA muscle fatigue benchmark (dorsiflexion torque or angle amplitude), with R2 values of 0.840±0.054 and 0.794±0.065 under isometric and dynamic conditions, respectively. The findings in this study indicate that the US echogenicity signal is a computationally efficient signal that strongly represents FES-induced muscle fatigue. Its potential real-time implementation to detect fatigue can facilitate an FES closed-loop controller design that considers the FES-induced muscle fatigue.
Collapse
Affiliation(s)
- Qiang Zhang
- UNC/NCSU Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA; (Q.Z.); (A.I.); (K.L.)
- UNC/NCSU Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA
| | - Ashwin Iyer
- UNC/NCSU Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA; (Q.Z.); (A.I.); (K.L.)
- UNC/NCSU Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA
| | - Krysten Lambeth
- UNC/NCSU Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA; (Q.Z.); (A.I.); (K.L.)
- UNC/NCSU Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA
| | - Kang Kim
- The Department of Bioengineering, School of Engineering, University of Pittsburgh, Pittsburgh, PA 15260, USA;
- The Center for Ultrasound Molecular Imaging and Therapeutics, Department of Medicine and Heart and Vascular Institute, University of Pittsburgh School of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA 15213, USA
- The Department of Mechanical Engineering and Materials Science, School of Engineering, University of Pittsburgh, Pittsburgh, PA 15260, USA
- The McGowan Institute for Regenerative Medicine, University of Pittsburgh Medical Center, University of Pittsburgh, Pittsburgh, PA 15219, USA
| | - Nitin Sharma
- UNC/NCSU Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA; (Q.Z.); (A.I.); (K.L.)
- UNC/NCSU Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA
- Correspondence: ; Tel.: +1-919-513-0787
| |
Collapse
|
22
|
Zhang Q, Iyer A, Lambeth K, Kim K, Sharma N. Ultrasound Echogenicity-based Assessment of Muscle Fatigue During Functional Electrical Stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5948-5952. [PMID: 34892473 DOI: 10.1109/embc46164.2021.9630325] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The rapid onset of muscle fatigue during functional electrical stimulation (FES) is a major challenge when attempting to perform long-term periodic tasks such as walking. Surface electromyography (sEMG) is frequently used to detect muscle fatigue for both volitional and FES-evoked muscle contraction. However, sEMG contamination from both FES stimulation artifacts and residual M-wave signals requires sophisticated processing to get clean signals and evaluate the muscle fatigue level. The objective of this paper is to investigate the feasibility of computationally efficient ultrasound (US) echogenicity as a candidate indicator of FES-induced muscle fatigue. We conducted isometric and dynamic ankle dorsiflexion experiments with electrically stimulated tibialis anterior (TA) muscle on three human participants. During a fatigue protocol, we synchronously recorded isometric dorsiflexion force, dynamic dorsiflexion angle, US images, and stimulation intensity. The temporal US echogenicity from US images was calculated based on a gray-scaled analysis to assess the decrease in dorsiflexion force or motion range due to FES-induced TA muscle fatigue. The results showed a monotonic reduction in US echogenicity change along with the fatigue progression for both isometric (R2 =0.870±0.026) and dynamic (R2 =0.803±0.048) ankle dorsiflexion. These results implied a strong linear relationship between US echogenicity and TA muscle fatigue level. The findings indicate that US echogenicity may be a promising computationally efficient indicator for assessing FES-induced muscle fatigue and may aid in the design of muscle-in-the-loop FES controllers that consider the onset of muscle fatigue.
Collapse
|
23
|
Rodriguez-Lopez C, Alcazar J, Sanchez-Martin C, Baltasar-Fernandez I, Ara I, Csapo R, Alegre LM. Neuromuscular adaptations after 12 weeks of light- vs. heavy-load power-oriented resistance training in older adults. Scand J Med Sci Sports 2021; 32:324-337. [PMID: 34618979 DOI: 10.1111/sms.14073] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 10/02/2021] [Accepted: 10/05/2021] [Indexed: 12/24/2022]
Abstract
This study aimed to determine the specific adaptations provoked by power-oriented resistance training using light (LL-PT, 40% 1-RM) vs. heavy (HL-PT, 80% 1-RM) loads in older adults. Using a randomized within-subject study design, 45 older adults (>65 years) completed an 8-week control period (CTR) followed by 12 weeks of unilateral LL-PT vs. HL-PT on a leg press. The 1-RM, theoretical force at zero velocity (F0 ), maximal unloaded velocity (V0 ), and maximal muscle power (Pmax ) were determined through a force-velocity relationship test. Isometrically, the rate of force development (RFD) and the corresponding muscle excitation of the knee extensor muscles were assessed. In addition, muscle cross-sectional area (CSA) and architecture of two quadriceps muscles were determined. Changes after CTR, LL-PT and HL-PT were compared using linear mixed models. HL-PT provoked greater improvements in 1-RM and F0 (effect size (ES) = 0.55-0.68; p < 0.001) than those observed after LL-PT (ES = 0.27-0.47; p ≤ 0.001) (post hoc treatment effect, p ≤ 0.057). By contrast, ES of changes in V0 was greater in LL-PT compared to HL-PT (ES = 0.71, p < 0.001 vs. ES = 0.39, p < 0.001), but this difference was not statistically significant. Both power training interventions elicited a moderate increase in Pmax (ES = 0.65-0.69, p < 0.001). Only LL-PT improved early RFD (ie, ≤100 ms) and muscle excitation (ES = 0.36-0.60, p < 0.05). Increased CSA were noted after both power training programs (ES = 0.13-0.35, p < 0.035), whereas pennation angle increased only after HL-PT (ES = 0.37, p = 0.004). In conclusion, HL-PT seems to be more effective in improving the capability to generate large forces, whereas LL-PT appears to trigger greater gains in movement velocity in older adults. However, both interventions promoted similar increases in muscle power as well as muscle hypertrophy.
Collapse
Affiliation(s)
- Carlos Rodriguez-Lopez
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Julian Alcazar
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Coral Sanchez-Martin
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Ivan Baltasar-Fernandez
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Ignacio Ara
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Robert Csapo
- Centre for Sport Science and University Sports, University of Vienna, Vienna, Austria
| | - Luis M Alegre
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| |
Collapse
|
24
|
May S, Locke S, Kingsley M. Reliability of ultrasonographic measurement of muscle architecture of the gastrocnemius medialis and gastrocnemius lateralis. PLoS One 2021; 16:e0258014. [PMID: 34587209 PMCID: PMC8480904 DOI: 10.1371/journal.pone.0258014] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 09/15/2021] [Indexed: 11/28/2022] Open
Abstract
Ultrasonography is widely used to measure gastrocnemius muscle architecture; however, it is unclear if values obtained from digitised images are sensitive enough to track architectural responses to clinical interventions. The purpose of this study was to explore the reliability and determine the minimal detectable change (MDC) of gastrocnemius medialis (GM) and gastrocnemius lateralis (GL) muscle architecture using ultrasound in a clinical setting. A trained sonographer obtained three B-mode images from each of the GM and GL muscles in 87 volunteers (44 males, 43 females; 22±9 years of age) on two separate occasions. Three independent investigators received training, then digitised the images to determine intra-rater, inter-rater, and test-retest reliability for fascicle length (FL), pennation angle (θ) and muscle thickness. Median FL, θ, and muscle thickness for GM and GL were 53.6–55.7 mm and 65.8–69.3 mm, 18.7–19.5° and 11.9–12.5°, and 12.8–13.2 mm and 15.9–16.9 mm, respectively. Intra- and inter-rater reliability of manual digitisation was excellent for all parameters. Test-retest reliability was moderate to excellent with intraclass correlation coefficient (ICC) values ≥0.80 for FL, ≥0.61 for θ, and ≥0.81 for muscle thickness, in both GM and GL. The respective MDC for GM and GL FL, θ, and muscle thickness was ≤12.1 mm and ≤18.00 mm, ≤6.4° and ≤4.2°, and ≤3.2 mm and ≤3.1 mm. Although reliable, the relatively large MDC suggest that clinically derived ultrasound measurements of muscle architecture in GM and GL are more likely to be useful to detect differences between populations than to detect changes in muscle architecture following interventions.
Collapse
Affiliation(s)
- Samantha May
- La Trobe Rural Health School, La Trobe University, Bendigo, Victoria, Australia
| | - Simon Locke
- La Trobe Rural Health School, La Trobe University, Bendigo, Victoria, Australia
| | - Michael Kingsley
- Holsworth Research Initiative, La Trobe University, Bendigo, Victoria, Australia.,Department of Exercise Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
25
|
Pincheira PA, Hoffman BW, Cresswell AG, Carroll TJ, Brown NAT, Lichtwark GA. Cyclic eccentric stretching induces more damage and improved subsequent protection than stretched isometric contractions in the lower limb. Eur J Appl Physiol 2021; 121:3349-3360. [PMID: 34436674 DOI: 10.1007/s00421-021-04787-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 08/09/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Controversy remains about whether exercise-induced muscle damage (EIMD) and the subsequent repeated bout effect (RBE) are caused by the stretching of an activated muscle, or the production of high force at long, but constant, muscle lengths. The aim of this study was to determine the influence of muscle fascicle stretch elicited during different muscle contraction types on the magnitude of EIMD and the RBE. METHODS Fourteen participants performed an initial bout of lower limb exercise of the triceps surae. One leg performed sustained static contractions at a constant long muscle length (ISO), whereas the contralateral leg performed a bout of eccentric heel drop exercise (ECC). Time under tension was matched between the ECC and ISO conditions. Seven days later, both legs performed ECC. Plantar flexor twitch torque, medial gastrocnemius (MG) fascicle length and muscle soreness were assessed before, 2 h and 2 days after each exercise bout. MG fascicle length and triceps surae surface electromyography were examined across the bouts of exercise. RESULTS We found that both ECC and ISO conditions elicited EIMD and a RBE. ISO caused less damage 2 h after the initial bout (14% less drop in twitch torque, P = 0.03) and less protection from soreness 2 days after the repeated bout (56% higher soreness, P = 0.01). No differences were found when comparing neuromechanical properties across exercise bouts. CONCLUSION For MG, the action of stretching an active muscle seems to be more important for causing damage than a sustained contraction at a long length.
Collapse
Affiliation(s)
- Patricio A Pincheira
- Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, 4072, Australia.
| | - Ben W Hoffman
- Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, 4072, Australia.,School of Health and Wellbeing, University of Southern Queensland, Toowoomba, QLD, Australia
| | - Andrew G Cresswell
- Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Timothy J Carroll
- Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Nicholas A T Brown
- Research Institute for Sport and Exercise, University of Canberra, Canberra, ACT, Australia
| | - Glen A Lichtwark
- Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, 4072, Australia
| |
Collapse
|
26
|
Krupenevich RL, Funk CJ, Franz JR. Automated analysis of medial gastrocnemius muscle-tendon junction displacements in heathy young adults during isolated contractions and walking using deep neural networks. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 206:106120. [PMID: 33991901 PMCID: PMC8223120 DOI: 10.1016/j.cmpb.2021.106120] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 04/14/2021] [Indexed: 05/31/2023]
Abstract
BACKGROUND AND OBJECTIVE Direct measurement of muscle-tendon junction (MTJ) position is important for understanding dynamic tendon behavior and muscle-tendon interaction in healthy and pathological populations. Traditionally, obtaining MTJ position during functional activities is accomplished by manually tracking the position of the MTJ in cine B-mode ultrasound images - a laborious and time-consuming process. Recent advances in deep learning have facilitated the availability of user-friendly open-source software packages for automated tracking. However, these software packages were originally intended for animal pose estimation and have not been widely tested on ultrasound images. Therefore, the purpose of this paper was to evaluate the efficacy of deep neural networks to accurately track medial gastrocnemius MTJ positions in cine B-mode ultrasound images across tasks spanning controlled loading during isolated contractions to physiological loading during treadmill walking. METHODS Cine B-mode ultrasound images of the medial gastrocnemius MTJ were collected from 15 subjects (6M/9F, 23 yr, 71.9 kg, 1.8 m) during treadmill walking at 1.25 m/s and during maximal voluntary isometric plantarflexor contractions (MVICs). Five deep neural networks were trained using 480 manually-labeled images collected during walking, defined as the ground truth, and were then used to predict MTJ position in images from novel subjects: 1) during walking (novel-subject) and 2) during MVICs (novel-condition). RESULTS We found an average mean absolute error of 1.26±1.30 mm and 2.61±3.31 mm between the ground truth and predicted MTJ positions in the novel-subject and novel-condition evaluations, respectively. CONCLUSIONS Our results provide support for the use of open-source software for creating deep neural networks to reliably track MTJ positions in B-mode ultrasound images. We believe this approach to MTJ position tracking is an accessible and time-saving solution, with broad applications for many fields, such as rehabilitation or clinical diagnostics.
Collapse
Affiliation(s)
- Rebecca L Krupenevich
- Joint Department of Biomedical Engineering, UNC Chapel Hill & NC State University, Chapel Hill 27599, NC, USA.
| | - Callum J Funk
- Joint Department of Biomedical Engineering, UNC Chapel Hill & NC State University, Chapel Hill 27599, NC, USA
| | - Jason R Franz
- Joint Department of Biomedical Engineering, UNC Chapel Hill & NC State University, Chapel Hill 27599, NC, USA
| |
Collapse
|
27
|
Ritsche P, Wirth P, Franchi MV, Faude O. ACSAuto-semi-automatic assessment of human vastus lateralis and rectus femoris cross-sectional area in ultrasound images. Sci Rep 2021; 11:13042. [PMID: 34158572 PMCID: PMC8219722 DOI: 10.1038/s41598-021-92387-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 06/07/2021] [Indexed: 01/19/2023] Open
Abstract
Open-access scripts to perform muscle anatomical cross-sectional area (ACSA) evaluation in ultrasound images are currently unavailable. This study presents a novel semi-automatic ImageJ script (named "ACSAuto") for quantifying the ACSA of lower limb muscles. We compared manual ACSA measurements from 180 ultrasound scans of vastus lateralis (VL) and rectus femoris (RF) muscles to measurements assessed by the ACSAuto script. We investigated inter- and intra-investigator reliability of the script. Consecutive-pairwise intra-class correlations (ICC) and standard error of measurement (SEM) with 95% compatibility interval were calculated. Bland-Altman analyses were employed to test the agreement between measurements. Comparing manual and ACSAuto measurements, ICCs and SEMs ranged from 0.96 to 0.999 and 0.12 to 0.96 cm2 (1.2-5.9%) and mean bias was smaller than 0.5 cm2 (4.3%). Inter-investigator comparison revealed ICCs, SEMs and mean bias ranging from 0.85 to 0.999, 0.07 to 1.16 cm2 (0.9-7.6%) and - 0.16 to 0.66 cm2 (- 0.6 to 3.2%). Intra-investigator comparison revealed ICCs, SEMs and mean bias between 0.883-0.998, 0.07-0.93 cm2 (1.1-7.6%) and - 0.80 to 0.15 cm2 (- 3.4 to 1.8%). Image quality needs to be high for efficient and accurate ACSAuto analyses. Taken together, the ACSAuto script represents a reliable tool to measure RF and VL ACSA, is comparable to manual analysis and can reduce time needed to evaluate ultrasound images.
Collapse
Affiliation(s)
- Paul Ritsche
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland.
| | - Philipp Wirth
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| | - Martino V Franchi
- Institute of Physiology, Department of Biomedical Sciences, University of Padua, Padua, Italy
| | - Oliver Faude
- Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
| |
Collapse
|
28
|
Sarto F, Spörri J, Fitze DP, Quinlan JI, Narici MV, Franchi MV. Implementing Ultrasound Imaging for the Assessment of Muscle and Tendon Properties in Elite Sports: Practical Aspects, Methodological Considerations and Future Directions. Sports Med 2021; 51:1151-1170. [PMID: 33683628 PMCID: PMC8124062 DOI: 10.1007/s40279-021-01436-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/06/2021] [Indexed: 12/16/2022]
Abstract
Ultrasound (US) imaging has been widely used in both research and clinical settings to evaluate the morphological and mechanical properties of muscle and tendon. In elite sports scenarios, a regular assessment of such properties has great potential, namely for testing the response to training, detecting athletes at higher risks of injury, screening athletes for structural abnormalities related to current or future musculoskeletal complaints, and monitoring their return to sport after a musculoskeletal injury. However, several practical and methodological aspects of US techniques should be considered when applying this technology in the elite sports context. Therefore, this narrative review aims to (1) present the principal US measures and field of applications in the context of elite sports; (2) to discuss, from a methodological perspective, the strengths and shortcomings of US imaging for the assessment of muscle and tendon properties; and (3) to provide future directions for research and application.
Collapse
Affiliation(s)
- Fabio Sarto
- Department of Biomedical Sciences, University of Padova, Padova, Italy
| | - Jörg Spörri
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- Department of Orthopaedics, University Centre for Prevention and Sports Medicine, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Daniel P Fitze
- Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Jonathan I Quinlan
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, UK
- National Institute for Health Research, Birmingham Biomedical Research Centre at University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Marco V Narici
- Department of Biomedical Sciences, University of Padova, Padova, Italy
- CIR-MYO Myology Centre, University of Padova, Padova, Italy
| | - Martino V Franchi
- Department of Biomedical Sciences, University of Padova, Padova, Italy.
| |
Collapse
|
29
|
Pelikh O, Pinnapireddy SR, Keck CM. Dermal Penetration Analysis of Curcumin in an ex vivo Porcine Ear Model Using Epifluorescence Microscopy and Digital Image Processing. Skin Pharmacol Physiol 2021; 34:281-299. [PMID: 33784713 DOI: 10.1159/000514498] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Accepted: 12/24/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Curcumin is a promising drug candidate, but its use for dermal application is limited due to its poor aqueous solubility. Thus, formulations that increase the solubility of curcumin are needed to fully exploit the therapeutic potential of curcumin. Various previous studies address this issue, but a comparison of the efficacy between these formulations remains difficult. The reason for this is a missing standard formulation as benchmark control and an easy-to-use skin penetration model that allows for a fast discrimination between different formulations. OBJECTIVE Thus, the aims of this study were the development of a curcumin standard formulation and a screening tool that allows for a fast discrimination between the dermal penetration efficacies of curcumin from different formulations. METHODS Ethanolic curcumin solutions were selected as simple and easy to produce standard formulations, and the ex vivo porcine ear model, coupled with epifluorescence microscopy and subsequent digital image analysis, was utilized to determine the dermal penetration efficacy of curcumin from the different formulations. RESULTS Results show that the utilized skin penetration model is a suitable and versatile tool that enables not only a fast determination of the dermal penetration efficacy of curcumin from different formulations but also a detailed and mechanistic information on the fate of chemical compounds after dermal penetration. Ethanolic solutions containing 0.25% curcumin were found to be the most suitable standard formulation. CONCLUSIONS Results of the study provide a new, effective screening tool for the development of dermal formulations for improved dermal delivery of curcumin.
Collapse
Affiliation(s)
- Olga Pelikh
- Department of Pharmaceutics and Biopharmaceutics, Philipps-Universität Marburg, Marburg, Germany
| | - Shashank R Pinnapireddy
- Department of Pharmaceutics and Biopharmaceutics, Philipps-Universität Marburg, Marburg, Germany.,CSL Behring GmbH, Marburg, Germany
| | - Cornelia M Keck
- Department of Pharmaceutics and Biopharmaceutics, Philipps-Universität Marburg, Marburg, Germany
| |
Collapse
|
30
|
Zheng W, Liu S, Chai QW, Pan JS, Chu SC. Automatic Measurement of Pennation Angle from Ultrasound Images using Resnets. ULTRASONIC IMAGING 2021; 43:74-87. [PMID: 33563138 DOI: 10.1177/0161734621989598] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this study, an automatic pennation angle measuring approach based on deep learning is proposed. Firstly, the Local Radon Transform (LRT) is used to detect the superficial and deep aponeuroses on the ultrasound image. Secondly, a reference line are introduced between the deep and superficial aponeuroses to assist the detection of the orientation of muscle fibers. The Deep Residual Networks (Resnets) are used to judge the relative orientation of the reference line and muscle fibers. Then, reference line is revised until the line is parallel to the orientation of the muscle fibers. Finally, the pennation angle is obtained according to the direction of the detected aponeuroses and the muscle fibers. The angle detected by our proposed method differs by about 1° from the angle manually labeled. With a CPU, the average inference time for a single image of the muscle fibers with the proposed method is around 1.6 s, compared to 0.47 s for one of the image of a sequential image sequence. Experimental results show that the proposed method can achieve accurate and robust measurements of pennation angle.
Collapse
Affiliation(s)
- Weimin Zheng
- College of Computer Science and Engineering, Shandong University of Science and Technology, Qingdao, China
| | - Shangkun Liu
- College of Computer Science and Engineering, Shandong University of Science and Technology, Qingdao, China
| | - Qing-Wei Chai
- College of Computer Science and Engineering, Shandong University of Science and Technology, Qingdao, China
| | - Jeng-Shyang Pan
- College of Computer Science and Engineering, Shandong University of Science and Technology, Qingdao, China
| | - Shu-Chuan Chu
- College of Computer Science and Engineering, Shandong University of Science and Technology, Qingdao, China
| |
Collapse
|
31
|
Rodriguez-Lopez C, Alcazar J, Losa-Reyna J, Martin-Espinosa NM, Baltasar-Fernandez I, Ara I, Csapo R, Alegre LM. Effects of Power-Oriented Resistance Training With Heavy vs. Light Loads on Muscle-Tendon Function in Older Adults: A Study Protocol for a Randomized Controlled Trial. Front Physiol 2021; 12:635094. [PMID: 33679447 PMCID: PMC7935559 DOI: 10.3389/fphys.2021.635094] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Accepted: 01/26/2021] [Indexed: 11/24/2022] Open
Abstract
Background Power-oriented resistance training (PRT) is one of the most effective exercise programs to counteract neuromuscular and physical function age-related declines. However, the optimal load that maximizes these outcomes or the load-specific adaptations induced on muscle power determinants remain to be better understood. Furthermore, to investigate whether these adaptations are potentially transferred to an untrained limb (i.e., cross-education phenomenon) could be especially relevant during limb-immobilization frequently observed in older people (e.g., after hip fracture). Methods At least 30 well-functioning older participants (>65 years) will participate in a within-person randomized controlled trial. After an 8-week control period, the effects of two 12-week PRT programs using light vs. heavy loads will be compared using an unilateral exercise model through three study arms (light-load PRT vs. non-exercise; heavy-load PRT vs. non-exercise; and light- vs. heavy- load PRT). Muscle-tendon function, muscle excitation and morphology and physical function will be evaluated to analyze the load-specific effects of PRT in older people. Additionally, the effects of PRT will be examined on a non-exercised contralateral limb. Discussion Tailored exercise programs are largely demanded given their potentially greater efficiency preventing age-related negative consequences, especially during limb-immobilization. This trial will provide evidence supporting the use of light- or heavy-load PRT on older adults depending on individual needs, improving decision making and exercise program efficacy. Clinical Trial Registration NCT03724461 registration data: October 30, 2018.
Collapse
Affiliation(s)
- Carlos Rodriguez-Lopez
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Julian Alcazar
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Jose Losa-Reyna
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain.,Department of Geriatrics, Hospital Virgen del Valle, Complejo Hospitalario de Toledo, Toledo, Spain
| | | | - Ivan Baltasar-Fernandez
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Ignacio Ara
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| | - Robert Csapo
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention, ISAG, University for Health Sciences, Medical Informatics and Technology, Hall in Tirol, Austria
| | - Luis M Alegre
- GENUD Toledo Research Group, Universidad de Castilla-La Mancha, Toledo, Spain.,CIBER of Frailty and Healthy Aging (CIBERFES), Madrid, Spain
| |
Collapse
|
32
|
Werkhausen A, E Solberg C, Paulsen G, Bojsen-Møller J, Seynnes OR. Adaptations to explosive resistance training with partial range of motion are not inferior to full range of motion. Scand J Med Sci Sports 2021; 31:1026-1035. [PMID: 33465838 DOI: 10.1111/sms.13921] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 12/16/2020] [Accepted: 01/11/2021] [Indexed: 01/20/2023]
Abstract
We tested whether explosive resistance training with partial range of motion (ROM) would be as effective as full ROM training using a noninferiority trial design. Fifteen subjects with strength training experience took part in an explosive-concentric only-leg press training program, three times per week for 10 weeks. One leg was randomly assigned to exercise with partial ROM (ie, 9º) and the other leg to full ROM. Before and after training, we assessed leg press performance, isokinetic concentric and isometric knee extension torque, and vastus lateralis muscle architecture. Overall, both training modalities increased maximal strength and rate of force development. Training with partial ROM yielded noninferior results compared to full ROM for leg press peak power (+69 ± 47% vs. +61 ± 64%), isokinetic strength (4-6 ± 6%-12% vs. 1-6 ± 6%-10% at 30, 60, and 180˚s-1 ), and explosive torque after 100 (47 ± 24 vs. 35 ± 22) and 150 ms (57 ± 22% vs. 42 ± 25%). The comparison was inconclusive for other functional parameters (ie, isokinetic peak torque (300˚s-1 ), joint angle at isokinetic peak torque, explosive torque after 50 ms, and electrically evoked torque) and for muscle fascicle length and thickness, although noninferiority was established for pennation angle. However, partial ROM was not found statistically inferior to full ROM for any measured variable. Under the present conditions, the effects of explosive heavy resistance training were independent of joint ROM. Instead, these data suggest that the distinct timing of muscle work in explosive contractions confers more influence to the starting joint angle than ROM on adaptations to this type of training.
Collapse
Affiliation(s)
- Amelie Werkhausen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Christian E Solberg
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Gøran Paulsen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway.,The Norwegian Olympic and Paralympic Committee and Confederation, Oslo, Norway
| | - Jens Bojsen-Møller
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway.,Research Unit for Muscle Physiology and Biomechanics, University of Southern Denmark, Odense, Denmark
| | - Olivier R Seynnes
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| |
Collapse
|
33
|
Kovács B, Kóbor I, Sebestyén Ö, Tihanyi J. Longer Achilles tendon moment arm results in better running economy. Physiol Int 2021; 107:527-541. [PMID: 33410770 DOI: 10.1556/2060.2020.10000] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 08/29/2020] [Indexed: 11/19/2022]
Abstract
Based on the current literature, the link between Achilles tendon moment arm length and running economy is not well understood. Therefore, the aim of this study was to further investigate the connection between Achilles tendon moment arm and running economy and the influence of Achilles tendon moment arm on the function of the plantarflexor muscle-tendon unit during running.Ten male competitive marathon runners volunteered for this study. The participants ran on a treadmill at two running speeds: 3 and 3.5 m s-1. During running the oxygen consumption, lower leg kinematics, electrical activity of plantar flexor muscles, and fascicle behavior of the lateral gastrocnemius were measured simultaneously. On the second occasion, an MRI scan of the right leg was taken and used to estimate the Achilles tendon moment arm length.There was a negative correlation between running economy and the body height normalized moment arm length at both selected speeds (r = -0.68, P = 0.014 and r = -0.70, P = 0.01). In addition, Achilles tendon moment arm length correlated with the amplitude of the ankle flexion at both speeds (r = -0.59, P = 0.03 and r = -0.60, P = 0.03) and with the electrical activity of the medial gastrocnemius muscle at 3 m s-1 speed (r = -0.62, P = 0.02). Our finding supports the concept that a longer moment arm could be beneficial for distance runners.
Collapse
Affiliation(s)
- B Kovács
- 1Department of Kinesiology, University of Physical Education, Budapest, Hungary
| | - I Kóbor
- 2Semmelweis University, MR Research Centre, Budapest, Hungary
| | - Ö Sebestyén
- 1Department of Kinesiology, University of Physical Education, Budapest, Hungary
| | - J Tihanyi
- 1Department of Kinesiology, University of Physical Education, Budapest, Hungary
| |
Collapse
|
34
|
Jabbar SI, Day C, Chadwick E. Automated measurements of morphological parameters of muscles and tendons. Biomed Phys Eng Express 2021. [DOI: 10.1088/2057-1976/abd3de] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Carbonaro M, Seynnes O, Maffiuletti NA, Busso C, Minetto MA, Botter A. Architectural Changes in Superficial and Deep Compartments of the Tibialis Anterior During Electrical Stimulation Over Different Sites. IEEE Trans Neural Syst Rehabil Eng 2020; 28:2557-2565. [PMID: 32986557 DOI: 10.1109/tnsre.2020.3027037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Electrical stimulation is widely used in rehabilitation to prevent muscle weakness and to assist the functional recovery of neural deficits. Its application is however limited by the rapid development of muscle fatigue due to the non-physiological motor unit (MU) recruitment. This issue can be mitigated by interleaving muscle belly (mStim) and nerve stimulation (nStim) to distribute the temporal recruitment among different MU groups. To be effective, this approach requires the two stimulation modalities to activate minimally-overlapped groups of MUs. In this manuscript, we investigated spatial differences between mStim and nStim MU recruitment through the study of architectural changes of superficial and deep compartments of tibialis anterior (TA). We used ultrasound imaging to measure variations in muscle thickness, pennation angle, and fiber length during mStim, nStim, and voluntary (Vol) contractions at 15% and 25% of the maximal force. For both contraction levels, architectural changes induced by nStim in the deep and superficial compartments were similar to those observed during Vol. Instead, during mStim superficial fascicles underwent a greater change compared to those observed during nStim and Vol, both in absolute magnitude and in their relative differences between compartments. These observations suggest that nStim results in a distributed MU recruitment over the entire muscle volume, similarly to Vol, whereas mStim preferentially activates the superficial muscle layer. The diversity between spatial recruitment of nStim and mStim suggests the involvement of different MU populations, which justifies strategies based on interleaved nerve/muscle stimulation to reduce muscle fatigue during electrically-induced contractions of TA.
Collapse
|
36
|
Cronin NJ, Finni T, Seynnes O. Using deep learning to generate synthetic B-mode musculoskeletal ultrasound images. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 196:105583. [PMID: 32544777 DOI: 10.1016/j.cmpb.2020.105583] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 05/29/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE Deep learning approaches are common in image processing, but often rely on supervised learning, which requires a large volume of training images, usually accompanied by hand-crafted labels. As labelled data are often not available, it would be desirable to develop methods that allow such data to be compiled automatically. In this study, we used a Generative Adversarial Network (GAN) to generate realistic B-mode musculoskeletal ultrasound images, and tested the suitability of two automated labelling approaches. METHODS We used a model including two GANs each trained to transfer an image from one domain to another. The two inputs were a set of 100 longitudinal images of the gastrocnemius medialis muscle, and a set of 100 synthetic segmented masks that featured two aponeuroses and a random number of 'fascicles'. The model output a set of synthetic ultrasound images and an automated segmentation of each real input image. This automated segmentation process was one of the two approaches we assessed. The second approach involved synthesising ultrasound images and then feeding these images into an ImageJ/Fiji-based automated algorithm, to determine whether it could detect the aponeuroses and muscle fascicles. RESULTS Histogram distributions were similar between real and synthetic images, but synthetic images displayed less variation between samples and a narrower range. Mean entropy values were statistically similar (real: 6.97, synthetic: 7.03; p = 0.218), but the range was much narrower for synthetic images (6.91 - 7.11 versus 6.30 - 7.62). When comparing GAN-derived and manually labelled segmentations, intersection-over-union values- denoting the degree of overlap between aponeurosis labels- varied between 0.0280 - 0.612 (mean ± SD: 0.312 ± 0.159), and pennation angles were higher for the GAN-derived segmentations (25.1° vs. 19.3°; p < 0.001). For the second segmentation approach, the algorithm generally performed equally well on synthetic and real images, yielding pennation angles within the physiological range (13.8-20°). CONCLUSIONS We used a GAN to generate realistic B-mode ultrasound images, and extracted muscle architectural parameters from these images automatically. This approach could enable generation of large labelled datasets for image segmentation tasks, and may also be useful for data sharing. Automatic generation and labelling of ultrasound images minimises user input and overcomes several limitations associated with manual analysis.
Collapse
Affiliation(s)
- Neil J Cronin
- Neuromuscular Research Centre, Faculty of Sport and Health Sciences, University of Jyvaskyla, Finland; Department for Health, Bath University, UK; School of Sport & Exercise, University of Gloucestershire, Gloucestershire, UK.
| | - Taija Finni
- Neuromuscular Research Centre, Faculty of Sport and Health Sciences, University of Jyvaskyla, Finland
| | | |
Collapse
|