1
|
Li J, Wei WF, Song LN, Mei XY, Yuan XS, He JB, Jiang LZ, Li HY, Wu HL, Chen JP. Double low-dose computed tomography (CT) angiography of craniocervical arteries using a test bolus of diluted contrast medium and a personalized contrast protocol. Clin Radiol 2024; 79:e1330-e1338. [PMID: 39198109 DOI: 10.1016/j.crad.2024.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 07/24/2024] [Accepted: 07/29/2024] [Indexed: 09/01/2024]
Abstract
AIM To prospectively assess the value of a test bolus of diluted contrast medium (CM) combined with a personalized contrast protocol in craniocervical computed tomography angiography (cc-CTA) with low radiation and CM doses. MATERIALS AND METHODS Eighty-six consecutive subjects were divided into two groups at random (43 in each one): group A: 100/Sn140 kVp, filtered back-projection reconstruction, iopromide (370 mgI/ml) 50 ml; group B: 80/Sn140 kVp, iterative reconstruction, iodixanol (270 mgI/ml). In group B, the test bolus contained 27 ml of diluted CM, a personalized protocol with low-concentration CM was used for angiography, and the test bolus injection duration in angiography remained the same. Artery values over 200 Hounsfield units were considered significant. RESULTS Image quality for all cases was found to be diagnostic. No significant differences were found in the arterial densities of the ascending aorta or basilar artery between the groups. The values of the common carotid artery, internal carotid artery, and middle cerebral artery in group B were significantly lower. The effective dose and average iodine uptake were significantly lower in group B. CONCLUSION With double-low-dose cc-CTA, test bolus scanning based on diluted CM combined with a personalized contrast protocol can yield diagnostic-quality images and significantly reduce the radiation and CM doses.
Collapse
Affiliation(s)
- J Li
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - W-F Wei
- Department of Neurosurgery, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - L-N Song
- Medical Record Department, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - X-Y Mei
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - X-S Yuan
- Department of Neurosurgery, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - J-B He
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - L-Z Jiang
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China
| | - H-Y Li
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China.
| | - H-L Wu
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China.
| | - J-P Chen
- Department of Radiology, Wujin Hospital Affiliated to Jiangsu University, Wujin Clinical College of Xuzhou Medical University, Changzhou 213002, Jiangsu, China.
| |
Collapse
|
2
|
Tsalafoutas IA, AlKhazzam S, Kharita MH. The impact of automatic tube current modulation related settings of a modern GE CT scanner on image quality and patient dose; details do matter. J Appl Clin Med Phys 2024; 25:e14356. [PMID: 38659159 PMCID: PMC11163491 DOI: 10.1002/acm2.14356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 03/12/2024] [Accepted: 03/18/2024] [Indexed: 04/26/2024] Open
Abstract
PURPOSE To investigate the operation principles of the automatic tube current modulation (ATCM) of a modern GE healthcare CT scanner, and the impact of related settings on image quality and patient dose. MATERIAL & METHODS A dedicated phantom (Mercury 4.0) was scanned using two of the most frequently used clinical scanning protocols (chest and abdomen-pelvis). The preset protocol settings were used as starting points (reference conditions). Scan direction, scan mode (helical vs. axial), total beam width, tube potential (kVp), and ATCM settings were then modified individually to understand their impact on radiation dose and image quality. Regarding the ATCM settings, the SmartmA minimum and maximum mA limits, and the noise index (NI) values were varied. As surrogates of patient dose, the CTDIvol and DLP values of each scan were used. As surrogates of image quality were used the image noise and the detectability index (d') of five different materials (air, solid water, polystyrene, iodine, and bone) embedded in the Mercury phantom calculated with the ImQuest software. RESULTS The scanning direction did not have any effect on ATCM curves, unlike what has been observed in CT scanners from other manufacturers. Total beam width does matter, however, the SmartmA limit settings and kVp selection had the greatest impact on image quality and dose. It was seen that improper minimum mA limit settings practically invalidated the ATCM operation. In contrast, when full modulation was allowed without restrictions, noise standard deviation, and detectability index became much more consistent across the wide range of phantom diameters. For lower kVp settings an impressive dose reduction was observed that requires further investigation. CONCLUSION SmartmA is a tool that if not properly used may increase the patient doses considerably. Therefore, its settings should be carefully adjusted for each preset different clinical protocol.
Collapse
Affiliation(s)
- Ioannis A. Tsalafoutas
- Medical Physics SectionOccupational Health and Safety DepartmentHamad Medical CorporationDohaQatar
| | - Shady AlKhazzam
- Medical Physics SectionOccupational Health and Safety DepartmentHamad Medical CorporationDohaQatar
| | - Mohammed Hassan Kharita
- Medical Physics SectionOccupational Health and Safety DepartmentHamad Medical CorporationDohaQatar
| |
Collapse
|
3
|
Im DJ, Kim YH, Choo KS, Kang JW, Jung JI, Won Y, Kim HR, Chung MH, Han K, Choi BW. Comparison of Coronary Computed Tomography Angiography Image Quality With High-concentration and Low-concentration Contrast Agents: The Randomized CONCENTRATE Trial. J Thorac Imaging 2023; 38:120-127. [PMID: 36821380 DOI: 10.1097/rti.0000000000000633] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To confirm that the image quality of coronary computed tomography (CT) angiography with a low tube voltage (80 to 100 kVp), iterative reconstruction, and low-concentration contrast agents (iodixanol 270 to 320 mgI/mL) was not inferior to that with conventional high tube voltage (120 kVp) and high-concentration contrast agent (iopamidol 370 mgI/mL). MATERIALS AND METHODS This prospective, multicenter, noninferiority, randomized trial enrolled a total of 318 patients from 8 clinical sites. All patients were randomly assigned 1: 1: 1 for each contrast medium of 270, 320, and 370 mgI/mL. CT scans were taken with a standard protocol in the high-concentration group (370 mgI/mL) and with 20 kVp lower protocol in the low-concentration group (270 or 320 mgI/mL). Image quality and radiation dose were compared between the groups. Image quality was evaluated with a score of 1 to 4 as subject image quality. RESULTS The mean HU, signal-to-noise ratio, and contrast-to-noise ratio of the 3 groups were significantly different (all P<0.0001). The signal-to-noise ratio and contrast-to-noise ratio of the low-concentration groups were significantly lower than those of the high-concentration group (P<0.05). However, the image quality scores were not significantly different among the 3 groups (P=0.745). The dose length product and effective dose of the high-concentration group were significantly higher than those of the low-concentration group (P<0.0001 and 0.003, respectively). CONCLUSIONS The CT protocol with iterative reconstruction and lower tube voltage for low-concentration contrast agents significantly reduced the effective radiation dose (mean: 3.7±2.7 to 4.1±3.1 mSv) while keeping the subjective image quality as good as the standard protocol (mean: 5.7±3.4 mSv).
Collapse
Affiliation(s)
- Dong Jin Im
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine
| | - Yun-Hyeon Kim
- Department of Radiology, Chonnam National University Hospital, Chonnam University Medical School, Gwangju
| | - Ki Seok Choo
- Department of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan
| | - Joon-Won Kang
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Jung Im Jung
- Department of Radiology, Seoul St. Mary's Hospital
| | - Yoodong Won
- Department of Radiology, Uijeongbu St. Mary's Hospital, Catholic University of Korea, Uijeongbu
| | - Hyo Rim Kim
- Department of Radiology, Yeouido St. Mary's Hospital, Catholic University of Korea, Seoul
| | - Myung Hee Chung
- Department of Radiology, Bucheon St. Mary's Hospital, Catholic University of Korea, Bucheon, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine
| | - Byoung Wook Choi
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine
| |
Collapse
|
4
|
Li M, Liu J, Chen F, Fan C, Yang X, Sun X. Contrast-induced encephalopathy following endovascular treatment for intracranial aneurysms-risk factors analysis and clinical strategy. Neuroradiology 2023; 65:629-635. [PMID: 36287224 DOI: 10.1007/s00234-022-03077-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 10/19/2022] [Indexed: 10/31/2022]
Abstract
PURPOSE Contrast-induced encephalopathy (CIE) was defined as new onset of neurological deficits after exposure to contrast media, which could be observed after the endovascular treatment for intracranial aneurysms. METHODS We enrolled a consecutive cohort of patients who underwent endovascular treatment for unruptured intracranial aneurysms. CIE was defined as a reversible neuropathic syndrome that occurred after interventional therapy, accompanied by imaging abnormalities and excluding other diseases. Multivariable Poisson regression analysis was performed to show risk factors by incidence rate ratio (IRR) and a clinical strategy was proposed. RESULTS Among the 579 patients who underwent interventional therapy for intracranial aneurysms, the crude incidence rate of CIE was 2.4% (95% CI, 1.2-3.6%) at our center. Headache, hemiplegia, and disorientation could be initial symptoms, and cortical blindness was the most common localized deficit. Cerebral edema and sulci effacement on CT were observed, and re-revaluation after treatments on CT/MRI showed absent lesions. The risk factors were history of stroke (IRR, 7.752; P = 0.007), history of hypertension (IRR, 1.064; P = 0.042), posterior circulation aneurysms (IRR, 9.412; P = 0.004) and higher dosage of contrast agents (IRR, 1.018; P = 0.007). After the strategy of accelerating excretion of contrast agents, reduction of intracranial pressure and anti-inflammation/vasospasm therapy, the prognosis was favorable with most patients fully recovered within 72 h. CONCLUSION History of stroke and posterior circulation aneurysms were main risk factors for CIE. A higher dosage of contrast agents might induce CIE, and the history of hypertension should be considered as well.
Collapse
Affiliation(s)
- Mengxing Li
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Jian Liu
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Feng Chen
- Department of Medical Statistics, School of Public Health, Sun Yat-Sen University, Guangzhou, China
| | - Chengzhe Fan
- Department of Neurology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Xinjian Yang
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Xuan Sun
- Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, No. 119, South 4th Ring West Road, Fengtai District, Beijing, China.
| |
Collapse
|
5
|
Kim J, Kim JY, Oh SW, Kim HG. Evaluating the Image Quality of Neck Structures Scanned on Chest CT with Low-Concentration-Iodine Contrast Media. Tomography 2022; 8:2854-2863. [PMID: 36548531 PMCID: PMC9785131 DOI: 10.3390/tomography8060239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/21/2022] [Accepted: 11/24/2022] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The purpose of this study was to investigate and compare the image quality of low-concentration-iodine (240 mgI/mL) contrast media (CM) and high-concentration-iodine (320 mgI/mL) CM according to the radiation dose. METHODS A total of 366 CT examinations were examined. Based on an assessment of quantitative and qualitative parameters by two radiologists, the quality was compared between Group A (low-concentration-iodine CM) and Group B (high-concentration-iodine CM) images of thyroid gland, sternocleidomastoid muscle (SCM), internal jugular vein (IJV), and common carotid artery (CCA). Another subgroup analysis compared Group a, (using ≤90 kVp in Group A), and Group b, (using ≥100 kVp in Group B) for finding the difference in image quality when the tube voltage is lowered. RESULTS Image quality did not differ between Groups A and B or between Groups a and b. The signal-to-noise ratio and contrast-to-noise ratio were significantly higher for Group B than Group A for the thyroid gland, IJV, and CCA. No statistical differences were found in the comparison of all structures between Groups a and b. CONCLUSION There was no significant difference in image quality based on CM concentration with variable radiation doses. Therefore, if an appropriate CT protocol is applied, clinically feasible neck CT images can be obtained even using low-concentration-iodine CM.
Collapse
Affiliation(s)
| | - Jee-Young Kim
- Department of Radiology, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 03312, Republic of Korea
| | | | | |
Collapse
|
6
|
Jiang J, Zhang M, Ji Y, Li C, Fang X, Zhang S, Wang W, Wang L, Liu A. An Individualized Contrast-Enhanced Liver Computed Tomography Imaging Protocol Based on Body Mass Index in 126 Patients Seen for Liver Cirrhosis. Med Sci Monit 2021; 27:e932109. [PMID: 34162827 PMCID: PMC8240488 DOI: 10.12659/msm.932109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background Computed tomography (CT) imaging using iodinated contrast medium is associated with the radiation dose to the patient, which may require reduction in individual circumstances. This study aimed to evaluate an individualized liver CT protocol based on body mass index (BMI) in 126 patients investigated for liver cirrhosis. Material/Methods From November 2017 to December 2020, in this prospective study, 126 patients with known or suspected liver cirrhosis were recruited. Patients underwent liver CT using individualized protocols based on BMI, as follows. BMI ≤24.0 kg/m2: 80 kV, 352 mg I/kg; BMI 24.1–28.0 kg/m2: 100 kV, 440 mg I/kg; BMI ≥28.1 kg/m2: 120 kV, 550 mg I/kg. Figure of merit (FOM) and size-specific dose estimates (SSDEs) were calculated and compared using the Mann-Whitney U test. Subjective image quality and timing adequacy of the late arterial phase were evaluated with Likert scales. Results The SSDE was significantly lower in the 80 kV protocol, corresponding to a dose reduction of 36% and 50% compared with the others (all P<0.001). In the comparison of 80-, 100-, and 120-kV protocols, no statistically significant differences were found in FOMs (P=0.108~0.620). Of all the examinations, 95.2% (120 of 126) were considered as appropriate timing for the late arterial phase. In addition, overall image quality, hepatocellular carcinoma conspicuity, and detection rate did not differ significantly among the 3 protocols (P=0.383~0.737). Conclusions This study demonstrated the feasibility of using an individualized liver CT protocol based on BMI, and showed that patients with lower BMI should receive lower doses of iodinated contrast medium and significantly reduced radiation dose.
Collapse
Affiliation(s)
- Jian Jiang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Maowei Zhang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Yuan Ji
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Chunfeng Li
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Xin Fang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Shuyuan Zhang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Wei Wang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China (mainland)
| | - Lijun Wang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| | - Ailian Liu
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, China (mainland)
| |
Collapse
|