1
|
Valerio TL, Anastácio R, da Silva SS, de Oliveira CC, Vidotti M. An overview of electrochemical biosensors used for COVID-19 detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2164-2176. [PMID: 38536084 DOI: 10.1039/d3ay02042h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
This short review presents the latest advances in the field of electrochemical biosensors, focusing particularly on impedimetric biosensors for the direct measurement of analytes. As a source of study we have chosen to describe these advances in the latest global health crisis originated from the COVID-19 pandemic, initiated by the SARS-CoV-2 virus. In this period, the necessity for swift and precise detection methods has grown rapidly due to an imminent need for the development of an analytical method to identify and isolate infected patients as an attempt to control the spreading of the disease. Traditional approaches such as the enzyme-linked immunosorbent assay (ELISA), were extensively used during the SARS-CoV-2 pandemic, but their drawbacks, including slow response time, became evident. In this context, the potential of electrochemical biosensors as an alternative for COVID-19 detection was emphasized. These biosensors merge electrochemical technology with bioreceptors, offering benefits such as rapidity, accuracy, portability, and real-time result provision. Additionally, we present instances of electrochemical biosensors modified with conductive polymers, eliminating the necessity for an electrochemical probe. The adaptability of the developed materials and devices facilitated the prompt production of electrochemical biosensors during the pandemic, creating opportunities for broader applications in infectious disease diagnosis.
Collapse
Affiliation(s)
- Tatiana Lima Valerio
- Grupo de Pesquisa em Macromoléculas e Interfaces, Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil.
| | - Raquel Anastácio
- Grupo de Pesquisa em Macromoléculas e Interfaces, Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil.
| | - Stella Schuster da Silva
- Laboratório de Células Inflamatórias e Neoplásicas (LCIN) e Laboratório de Investigação de Polissacarídeos Sulfatados (LIPS), Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil
| | - Carolina Camargo de Oliveira
- Laboratório de Células Inflamatórias e Neoplásicas (LCIN) e Laboratório de Investigação de Polissacarídeos Sulfatados (LIPS), Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil
| | - Marcio Vidotti
- Grupo de Pesquisa em Macromoléculas e Interfaces, Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil.
| |
Collapse
|
2
|
Glasco DL, Sheelam A, Ho NHB, Bell JG. Smartphone-based detection of levodopa in human sweat using 3D printed sensors. Anal Chim Acta 2023; 1273:341546. [PMID: 37423672 DOI: 10.1016/j.aca.2023.341546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 06/08/2023] [Accepted: 06/20/2023] [Indexed: 07/11/2023]
Abstract
Parkinson's disease (PD) is one of the leading neurological disorders negatively impacting health on a global scale. Patients diagnosed with PD require frequent monitoring, prescribed medications, and therapy for extended periods as symptom severity worsens. The primary pharmaceutical treatment for PD patients is levodopa (L-Dopa) which reduces many symptoms experienced by PD patients (e.g., tremors, cognitive ability, motor dysfunction, etc.) through the regulation of dopamine levels in the body. Herein, the first detection of L-Dopa in human sweat using a low-cost 3D printed sensor with a simple and rapid fabrication protocol combined with a portable potentiostat wirelessly connected to a smartphone via Bluetooth is reported. By combining saponification and electrochemical activation into a single protocol, the optimized 3D printed carbon electrodes were able to simultaneously detect uric acid and L-Dopa throughout their biologically relevant ranges. The optimized sensors provided a sensitivity of 83 ± 3 nA/μM from 24 μM to 300 nM L-Dopa. Common physiological interferents found in sweat (e.g., ascorbic acid, glucose, caffeine) showed no influence on the response for L-Dopa. Lastly, a percent recovery of L-Dopa in human sweat using a smartphone-assisted handheld potentiostat resulted in the recovery of 100 ± 8%, confirming the ability of this sensor to accurately detect L-Dopa in sweat.
Collapse
Affiliation(s)
- Dalton L Glasco
- Department of Chemistry, Washington State University, Pullman, WA, 99163, USA
| | - Anjaiah Sheelam
- Department of Chemistry, Washington State University, Pullman, WA, 99163, USA
| | - Nguyen H B Ho
- Department of Chemistry, Washington State University, Pullman, WA, 99163, USA
| | - Jeffrey G Bell
- Department of Chemistry, Washington State University, Pullman, WA, 99163, USA.
| |
Collapse
|
3
|
Petrunin AA, Rabchinskii MK, Sysoev VV, Glukhova OE. Adaptive Peptide Molecule as the Promising Highly-Efficient Gas-Sensor Material: In Silico Study. SENSORS (BASEL, SWITZERLAND) 2023; 23:5780. [PMID: 37447630 PMCID: PMC10346805 DOI: 10.3390/s23135780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 06/12/2023] [Accepted: 06/17/2023] [Indexed: 07/15/2023]
Abstract
Gas sensors are currently employed in various applications in fields such as medicine, ecology, and food processing, and serve as monitoring tools for the protection of human health, safety, and quality of life. Herein, we discuss a promising direction in the research and development of gas sensors based on peptides-biomolecules with high selectivity and sensitivity to various gases. Thanks to the technique developed in this work, which uses a framework based on the density-functional tight-binding theory (DFTB), the most probable adsorption centers were identified and used to describe the interaction of some analyte molecules with peptides. The DFTB method revealed that the physical adsorption of acetone, ammonium, benzene, ethanol, hexane, methanol, toluene, and trinitrotoluene had a binding energy in the range from -0.28 eV to -1.46 eV. It was found that peptides may adapt to the approaching analyte by changing their volume up to a maximum value of approx. 13%, in order to confine electron clouds around the adsorbed molecule. Based on the results obtained, the prospects for using the proposed peptide configurations in gas sensor devices are good.
Collapse
Affiliation(s)
- Alexander A. Petrunin
- Institute of Physics, Saratov State University, Astrakhanskaya Street 83, 410012 Saratov, Russia;
| | | | - Victor V. Sysoev
- Department of Physics, Yuri Gagarin State Technical University of Saratov, Polytechnicheskaya Street 77, 410054 Saratov, Russia
| | - Olga E. Glukhova
- Institute of Physics, Saratov State University, Astrakhanskaya Street 83, 410012 Saratov, Russia;
- Laboratory of Biomedical Nanotechnology, I.M. Sechenov First Moscow State Medical University, Trubetskaya Street 8-2, 119991 Moscow, Russia
| |
Collapse
|
4
|
Guliy OI, Evstigneeva SS, Khanadeev VA, Dykman LA. Antibody Phage Display Technology for Sensor-Based Virus Detection: Current Status and Future Prospects. BIOSENSORS 2023; 13:640. [PMID: 37367005 DOI: 10.3390/bios13060640] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 05/31/2023] [Accepted: 06/08/2023] [Indexed: 06/28/2023]
Abstract
Viruses are widespread in the environment, and many of them are major pathogens of serious plant, animal, and human diseases. The risk of pathogenicity, together with the capacity for constant mutation, emphasizes the need for measures to rapidly detect viruses. The need for highly sensitive bioanalytical methods to diagnose and monitor socially significant viral diseases has increased in the past few years. This is due, on the one hand, to the increased incidence of viral diseases in general (including the unprecedented spread of a new coronavirus infection, SARS-CoV-2), and, on the other hand, to the need to overcome the limitations of modern biomedical diagnostic methods. Phage display technology antibodies as nano-bio-engineered macromolecules can be used for sensor-based virus detection. This review analyzes the commonly used virus detection methods and approaches and shows the prospects for the use of antibodies prepared by phage display technology as sensing elements for sensor-based virus detection.
Collapse
Affiliation(s)
- Olga I Guliy
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Subdivision of the Federal State Budgetary Research Institution Saratov Federal Scientific Centre of the Russian Academy of Sciences (IBPPM RAS), 13 Prospect Entuziastov, Saratov 410049, Russia
| | - Stella S Evstigneeva
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Subdivision of the Federal State Budgetary Research Institution Saratov Federal Scientific Centre of the Russian Academy of Sciences (IBPPM RAS), 13 Prospect Entuziastov, Saratov 410049, Russia
| | - Vitaly A Khanadeev
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Subdivision of the Federal State Budgetary Research Institution Saratov Federal Scientific Centre of the Russian Academy of Sciences (IBPPM RAS), 13 Prospect Entuziastov, Saratov 410049, Russia
| | - Lev A Dykman
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Subdivision of the Federal State Budgetary Research Institution Saratov Federal Scientific Centre of the Russian Academy of Sciences (IBPPM RAS), 13 Prospect Entuziastov, Saratov 410049, Russia
| |
Collapse
|
5
|
Ang PC, Perumal V, Ibrahim MNM, Adnan R, Mohd Azman DK, Gopinath SCB, Raja PB. Electrochemical biosensor detection on respiratory and flaviviruses. Appl Microbiol Biotechnol 2023; 107:1503-1513. [PMID: 36719432 PMCID: PMC9887245 DOI: 10.1007/s00253-023-12400-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 01/14/2023] [Accepted: 01/18/2023] [Indexed: 02/01/2023]
Abstract
Viruses have spread throughout the world and cause acute illness or death among millions of people. There is a growing concern about methods to control and combat early-stage viral infections to prevent the significant public health problem. However, conventional detection methods like polymerase chain reaction (PCR) requires sample purification and are time-consuming for further clinical diagnosis. Hence, establishing a portable device for rapid detection with enhanced sensitivity and selectivity for the specific virus to prevent further spread becomes an urgent need. Many research groups are focusing on the potential of the electrochemical sensor to become a key for developing point-of-care (POC) technologies for clinical analysis because it can solve most of the limitations of conventional diagnostic methods. Herein, this review discusses the current development of electrochemical sensors for the detection of respiratory virus infections and flaviviruses over the past 10 years. Trends in future perspectives in rapid clinical detection sensors on viruses are also discussed. KEY POINTS: • Respiratory related viruses and Flavivirus are being concerned for past decades. • Important to differentiate the cross-reactivity between the virus in same family. • Electrochemical biosensor as a suitable device to detect viruses with high performance.
Collapse
Affiliation(s)
- Phaik Ching Ang
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Gelugor, Penang, Malaysia
| | - Veeradasan Perumal
- Centre of Innovative Nanostructures and Nanodevices (COINN), Universiti Teknologi PETRONAS (UTP), Seri Iskandar, Perak, Malaysia
- Mechanical Engineering Department, Universiti Teknologi PETRONAS (UTP), Seri Iskandar, Perak, Malaysia
| | | | - Rohana Adnan
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Gelugor, Penang, Malaysia
| | - Daruliza Kernain Mohd Azman
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, 11800, Penang, Gelugor, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia
- Micro System Technology, Centre of Excellence (CoE), Universiti Malaysia Perlis (UniMAP), Pauh Campus, 02600, Arau, Perlis, Malaysia
| | - Pandian Bothi Raja
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Gelugor, Penang, Malaysia.
| |
Collapse
|
6
|
Fakhr MH, Beshchasna N, Balakin S, Carrasco IL, Heitbrink A, Göhler F, Rösch N, Opitz J. Cleaning of LTCC, PEN, and PCB Au electrodes towards reliable electrochemical measurements. Sci Rep 2022; 12:20431. [PMID: 36443326 PMCID: PMC9705539 DOI: 10.1038/s41598-022-23395-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 10/31/2022] [Indexed: 11/29/2022] Open
Abstract
Surface cleaning of the working electrode has a key role in improved electrochemical and physicochemical properties of the biosensors. Herein, chemical oxidation in piranha, chemical cleaning in potassium hydroxide-hydrogen peroxide, combined (electro-) chemical alkaline treatment, and potential cycling in sulfuric acid were applied to gold finish electrode surfaces deposited onto three different substrates; low temperature co-fired ceramics (LTCC), polyethylene naphthalate (PEN), and polyimide (PI), using three different deposition technologies; screen printing, inkjet printing, and electroplating (printed circuit board technology, PCB) accordingly. The effects of the (electro-) chemical treatments on the gold content and electrochemical responses of LTCC, PEN, and PCB applicable for aptamer-based sensors are discussed. In order to assess the gold surface and to compare the efficiency of the respective cleaning procedures; cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) were employed. LTCC sensors electrochemically cycled in sulfuric acid resulted in the most gold content on the electrode surface, the lowest peak potential difference, and the highest charge transfer ability. While, for PEN, the highest elemental gold and the lowest peak-to-peak separation were achieved by a combined (electro-) chemical alkaline treatment. Gold content and electrochemical characteristics on the PCB surface with extremely thin gold layer could be slightly optimized with the chemical cleaning in KOH + H2O2. The proposed cleaning procedures might be generally applied to various kinds of Au electrodes fabricated with the same conditions comparable with those are introduced in this study.
Collapse
Affiliation(s)
- Mahan Hosseinzadeh Fakhr
- grid.461622.50000 0001 2034 8950Fraunhofer Institute for Ceramic Technologies and Systems IKTS, 01109 Dresden, Germany ,grid.6810.f0000 0001 2294 5505Institute of Physics, Chemnitz University of Technology, 09126 Chemnitz, Germany
| | - Natalia Beshchasna
- grid.461622.50000 0001 2034 8950Fraunhofer Institute for Ceramic Technologies and Systems IKTS, 01109 Dresden, Germany
| | - Sascha Balakin
- grid.461622.50000 0001 2034 8950Fraunhofer Institute for Ceramic Technologies and Systems IKTS, 01109 Dresden, Germany
| | - Ivan Lopez Carrasco
- grid.461622.50000 0001 2034 8950Fraunhofer Institute for Ceramic Technologies and Systems IKTS, 01109 Dresden, Germany ,grid.4488.00000 0001 2111 7257Max Bergmann Center of Biomaterials (MBC), Technical University of Dresden, 01069 Dresden, Germany
| | - Alexander Heitbrink
- grid.461622.50000 0001 2034 8950Fraunhofer Institute for Ceramic Technologies and Systems IKTS, 01109 Dresden, Germany ,grid.4488.00000 0001 2111 7257Max Bergmann Center of Biomaterials (MBC), Technical University of Dresden, 01069 Dresden, Germany ,InnoME GmbH, 32339 Espelkamp, Germany
| | - Fabian Göhler
- grid.6810.f0000 0001 2294 5505Institute of Physics, Chemnitz University of Technology, 09126 Chemnitz, Germany
| | - Niels Rösch
- grid.6810.f0000 0001 2294 5505Institute of Physics, Chemnitz University of Technology, 09126 Chemnitz, Germany
| | - Joerg Opitz
- grid.461622.50000 0001 2034 8950Fraunhofer Institute for Ceramic Technologies and Systems IKTS, 01109 Dresden, Germany ,grid.4488.00000 0001 2111 7257Max Bergmann Center of Biomaterials (MBC), Technical University of Dresden, 01069 Dresden, Germany
| |
Collapse
|
7
|
A Review on Potential Electrochemical Point-of-Care Tests Targeting Pandemic Infectious Disease Detection: COVID-19 as a Reference. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070269] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Fast and accurate point-of-care testing (POCT) of infectious diseases is crucial for diminishing the pandemic miseries. To fight the pandemic coronavirus disease 2019 (COVID-19), numerous interesting electrochemical point-of-care (POC) tests have been evolved to rapidly identify the causal organism SARS-CoV-2 virus, its nucleic acid and antigens, and antibodies of the patients. Many of those electrochemical biosensors are impressive in terms of miniaturization, mass production, ease of use, and speed of test, and they could be recommended for future applications in pandemic-like circumstances. On the other hand, self-diagnosis, sensitivity, specificity, surface chemistry, electrochemical components, device configuration, portability, small analyzers, and other features of the tests can yet be improved. Therefore, this report reviews the developmental trend of electrochemical POC tests (i.e., test platforms and features) reported for the rapid diagnosis of COVID-19 and correlates any significant advancements with relevant references. POCTs incorporating microfluidic/plastic chips, paper devices, nanomaterial-aided platforms, smartphone integration, self-diagnosis, and epidemiological reporting attributes are also surfed to help with future pandemic preparedness. This review especially screens the low-cost and easily affordable setups so that management of pandemic disease becomes faster and easier. Overall, the review is a wide-ranging package for finding appropriate strategies of electrochemical POCT targeting pandemic infectious disease detection.
Collapse
|
8
|
Sharma S, Thomas E, Caputi M, Asghar W. RT-LAMP-Based Molecular Diagnostic Set-Up for Rapid Hepatitis C Virus Testing. BIOSENSORS 2022; 12:298. [PMID: 35624599 PMCID: PMC9138684 DOI: 10.3390/bios12050298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/23/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
Hepatitis C virus (HCV) infections occur in approximately 3% of the world population. The development of an enhanced and extensive-scale screening is required to accomplish the World Health Organization's (WHO) goal of eliminating HCV as a public health problem by 2030. However, standard testing methods are time-consuming, expensive, and challenging to deploy in remote and underdeveloped areas. Therefore, a cost-effective, rapid, and accurate point-of-care (POC) diagnostic test is needed to properly manage the disease and reduce the economic burden caused by high case numbers. Herein, we present a fully automated reverse-transcription loop-mediated isothermal amplification (RT-LAMP)-based molecular diagnostic set-up for rapid HCV detection. The set-up consists of an automated disposable microfluidic chip, a small surface heater, and a reusable magnetic actuation platform. The microfluidic chip contains multiple chambers in which the plasma sample is processed. The system utilizes SYBR green dye to detect the amplification product with the naked eye. The efficiency of the microfluidic chip was tested with human plasma samples spiked with HCV virions, and the limit of detection observed was 500 virions/mL within 45 min. The entire virus detection process was executed inside a uniquely designed, inexpensive, disposable, and self-driven microfluidic chip with high sensitivity and specificity.
Collapse
Affiliation(s)
- Sandhya Sharma
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA;
- Asghar-Lab: Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA
| | - Emmanuel Thomas
- Department of Microbiology and Immunology and Sylvester Comprehensive Cancer Center, University of Miami School of Medicine, Miami, FL 33136, USA;
| | - Massimo Caputi
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL 33431, USA;
| | - Waseem Asghar
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA;
- Asghar-Lab: Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA
- Department of Biological Sciences (Courtesy Appointment), Florida Atlantic University, Boca Raton, FL 33431, USA
| |
Collapse
|
9
|
Luta EP, Miller BL. Development of Methods for Specific Capture of Biological Targets on Aluminum Substrates: Application to Bacillus subtilis Spore Detection as a Model for Anthrax. SENSORS (BASEL, SWITZERLAND) 2022; 22:3441. [PMID: 35591130 PMCID: PMC9106032 DOI: 10.3390/s22093441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/20/2022] [Accepted: 04/26/2022] [Indexed: 02/04/2023]
Abstract
Many (if not most) biosensors rely on functional silane coatings as a first step toward covalent immobilization of specific capture molecules. While methods for silanization of silica (SiO2) surfaces are very well developed, less has been done to develop and characterize silanization methods for alternative substrates, such as alumina (Al2O3). In particular, the behavior of Al2O3 coatings grown on aluminum under ambient conditions has not been studied. To address this issue, we have tested solution-phase deposition of two silanes on Al2O3 (3-aminopropyl triethoxysilane and 3-triethoxysilyl)propylsuccinic anhydride) and their applicability to analyte-specific biosensing. Contact angle measurements and imaging via Scanning Electron Microsopy (SEM) were employed to characterize surfaces. We find that 3-aminopropyl triethoxysilane produces well-behaved films and demonstrate that this surface can undergo further reaction with glutaraldehyde followed by an anti-Bacillus subtilis antibody to yield functionalized Al2O3 surfaces capable of specific capture of B. subtilis spores (a model of B. anthracis, the causative organism of Anthrax). In contrast, 3-triethoxysilyl)propylsuccinic anhydride did not behave well with Al/Al2O3 under the reaction conditions tested. In addition to providing specific protocols for Al/Al2O3 functionalization, this work highlights the importance of surface chemistry assessment in the development of new sensors.
Collapse
Affiliation(s)
| | - Benjamin L. Miller
- Department of Dermatology, University of Rochester, Rochester, NY 14642, USA;
| |
Collapse
|
10
|
Bushra KA, Prasad KS. Paper-based field-effect transistor sensors. Talanta 2021; 239:123085. [PMID: 34890939 DOI: 10.1016/j.talanta.2021.123085] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 11/07/2021] [Accepted: 11/16/2021] [Indexed: 01/10/2023]
Abstract
The present scenario in the world largely demands affordable, fast, recyclable, and flexible electronic devices for bio sensing. Varieties of paper-based devices such as microfluidics paper electrodes, paper diodes, and paper-based transistors etc. have been developed and validated. Most of the fabrication techniques published so far have focused on economic, environment-friendly straightforward methods to develop paper-based field-effect transistors (PFET) sensors, additionally, explored their applications. The synthetic-free, mechanically flexible, biocompatible, and signal amplification capability render PFET based sensors for wearable device makers. Modified organic/inorganic PFETs identify target analytes based on the electrical signal and endow them as perfect transducers. In the field of PFET bio sensing technology, numerous challenges are needed to be discussed to proceed forward in biomedical and other analytical applications. Realizing biologically or chemically modified PFET having an exceptional signal to noise ratio, specificity, with rapid detection ability is challenging. This review recapitulates the fabrication techniques, performances of various PFET sensors, and summarizes the report by concluding remarks including the limitations of the existing PFET based sensors and the future holds in regards to the sustainable nature of PFET.
Collapse
Affiliation(s)
- K Ayshathil Bushra
- Nanomaterial Research Laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya University, Deralakatte, Mangalore, 575018, India.
| | - K Sudhakara Prasad
- Nanomaterial Research Laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya University, Deralakatte, Mangalore, 575018, India; Centre for Nutrition Studies, Yenepoya (Deemed to Be University), Deralakatte, Mangalore, 575 018, India.
| |
Collapse
|