1
|
Zubanov PS, Tregub PP, Goldberg AS, Godkov MA, Akimkin VG. Comprehensive assessment of medical laboratory performance: a 4D model of quality, economics, velocity, and productivity indicators. Clin Chem Lab Med 2025:cclm-2025-0323. [PMID: 40312975 DOI: 10.1515/cclm-2025-0323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2025] [Accepted: 04/23/2025] [Indexed: 05/03/2025]
Abstract
Laboratory diagnostics play a crucial role in modern medicine and healthcare economics. The effective management of a medical laboratory is based on reliable assessment of indicators characterizing quality of testing, productivity, velocity (speed) and cost-effectiveness. The usual concepts of laboratory management focus on one or two groups of these indicators and exclude a comprehensive assessment of the effectiveness of a medical laboratory. Various guidelines and concepts (ISO, Lean, Six Sigma, etc.) often provide similar approaches but use different terms. This review discusses common options for performance indicators in medical laboratories, as well as practical experience in using these indicators to assess the overall effectiveness of the laboratory and improve medical care for patients. All indicators were divided into four broad groups: quality, economy, velocity, and productivity. Based on these four groups, we describe the new" four-dimensional model" for assessment of medical laboratory performance based on different combinations of indicator groups for different types of laboratories.
Collapse
Affiliation(s)
| | - Pavel P Tregub
- Central Research Institute of Epidemiology, Moscow, Russia
- Department of Pathophysiology, I.M. Sechenov First Moscow State Medical University, Moscow, Russia
- RUDN University, Moscow, Russia
| | - Arkady S Goldberg
- The Federal State Budget Educational Institution of Additional Professional Education the Russian Medical Academy of Continuous Professional Education of Minzdrav of Russia, Moscow, Russia
| | - Mikhail A Godkov
- The Federal State Budget Educational Institution of Additional Professional Education the Russian Medical Academy of Continuous Professional Education of Minzdrav of Russia, Moscow, Russia
- Moscow Department of Healthcare, N.V. Sklifosovsky Research Institute of Emergency Medicine, Moscow, Russia
| | | |
Collapse
|
2
|
Panteghini M, Krintus M. Establishing, evaluating and monitoring analytical quality in the traceability era. Crit Rev Clin Lab Sci 2025; 62:148-181. [PMID: 39743528 DOI: 10.1080/10408363.2024.2434562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 07/16/2024] [Accepted: 11/22/2024] [Indexed: 01/04/2025]
Abstract
Poor analytical quality may be the bane of medical use of laboratory tests, and the fight against excessive analytical variability presents a daily struggle. Laboratories should prioritize the perspectives and needs of their customers (the patients and healthcare personnel). Among them, comparability of results from the same patient sample when measured by different laboratories using different in vitro diagnostic (IVD) medical devices is a logical priority to avoid result misinterpretation and potential patient harm. Harmonization (standardization) of laboratory measurements can be achieved by establishing metrological traceability of the results on clinical samples to stated higher-order references and providing an estimate of the uncertainty of measurement (MU). This estimate should be based on an MU budget including all known MU contributions generated by the employed calibration hierarchy, which in turn should be validated against fit-for-purpose maximum allowable MU derived according to internationally recommended models. In this report, we review the available strategies for establishing, evaluating, and monitoring analytical quality, drawing on three decades experience in the field. We discuss the most important aspects that may influence obtaining and maintaining analytical standardization in laboratory medicine, and offer practical solutions aimed at educating all stakeholders for the achievement of harmonized laboratory results. To fully implement the recommended approaches, all involved parties-i.e. reference providers, IVD manufacturers, medical laboratories, and External Quality Assessment organizers-must agree on their importance and enhance their specific knowledge.
Collapse
Affiliation(s)
- Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Torun, Poland
| | - Magdalena Krintus
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Torun, Poland
| |
Collapse
|
3
|
Çubukçu HC, Thelen M, Plebani M, Panteghini M. IFCC recommendations for internal quality control practice: a missed opportunity. Clin Chem Lab Med 2025:cclm-2025-0486. [PMID: 40287820 DOI: 10.1515/cclm-2025-0486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2025] [Accepted: 04/23/2025] [Indexed: 04/29/2025]
Abstract
The IFCC Task Force on Global Lab Quality (TF-GLQ) has recently released a new guidance for internal quality control (IQC) practice through an approach translating the general principles as stated in the ISO 15189:2022 standard to a series of practical recommendations. The paper contains however important inaccuracies and shortcomings that, in our opinion, make it a missed opportunity for providing a updated guidance for laboratory professionals. In particular, four important issues are discussed: a) how to design IQC strategies in the traceability era, b) how to define IQC acceptance limits, c) how to estimate measurement uncertainty using IQC data, and d) how to manage comparability between the results provided by different analyzers in the same laboratory. Our analysis underscores the necessity for a more systematic, updated, and evidence-based approach to produce an IQC recommendation in line with the IFCC tradition.
Collapse
Affiliation(s)
- Hikmet Can Çubukçu
- Rare Diseases Department, General Directorate of Health Services, Turkish Ministry of Health, Ankara, Turkiye
| | - Marc Thelen
- SKML, Nijmegen, The Netherlands
- Department of Laboratory Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | | | - Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Torun, Poland
| |
Collapse
|
4
|
Panteghini M. Not all biases are created equal: how to deal with bias on laboratory measurements. Clin Chem Lab Med 2025; 63:916-922. [PMID: 39585762 DOI: 10.1515/cclm-2024-1208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2024] [Accepted: 11/18/2024] [Indexed: 11/27/2024]
Abstract
Although the concept of bias appears consolidated in laboratory science, some important changes in its definition and management have occurred since the introduction of metrological traceability theory in laboratory medicine. In the traceability era, medical laboratories should rely on manufacturers who must ensure traceability of their in vitro diagnostic medical devices (IVD-MD) to the highest available references, providing bias correction during the trueness transfer process to calibrators before they are marketed. However, sometimes some bias can be observed arising from an insufficient correction during the traceability implementation. This source of bias can be discovered by the IVD-MD surveillance by traceability-based external quality assessment and confirmed by ad-hoc validation experiments. The assessment of significance should be based on its impact on measurement uncertainty (MU) of results. The IVD manufacturer, appropriately warned, is responsible to take an immediate investigation and eventually fix the problem with a corrective action. Even if IVD-MD is correctly aligned in the validation steps and bias components are eliminated, during ordinary use the system may undergo systematic variations such as those caused by recalibrations and lot changes. These sources of randomly occurring bias are incorporated in the estimate of intermediate reproducibility of IVD-MD through internal quality control and can be tolerated until the estimated MU on clinical samples fulfils the predefined specifications. A readjustment of the IVD-MD by the end-user must be undertaken to try to correct the bias becoming significant. If the bias remains, the IVD manufacturer should be requested to rectify the problem.
Collapse
Affiliation(s)
- Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| |
Collapse
|
5
|
Panteghini M, Wielgosz R. Supporting prioritization efforts of higher-order reference providers using evidence from the Joint Committee for Traceability in Laboratory Medicine database. Clin Chem Lab Med 2025:cclm-2025-0401. [PMID: 40205950 DOI: 10.1515/cclm-2025-0401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2025] [Accepted: 03/31/2025] [Indexed: 04/11/2025]
Abstract
The Joint Committee for Traceability in Laboratory Medicine (JCTLM) database represents a valuable resource for implementing metrological traceability in laboratory medicine. Three main database users can be identified: (a) in vitro diagnostic (IVD) manufacturers, using the database information for meeting ISO 17511:2020 requirements, (b) laboratory professionals, for defining the quality of their test results, and (c) providers of higher-order certified reference materials (CRM) and reference measurement procedures (RMP), to be helped in improving the suitability of their products, if needed, and assistance with prioritizing their future efforts. In this report, we focus on the utility of the information provided (or still not provided) by the JCTLM database on this last category of users. Two types of information are discussed: (a) the use of listed CRMs as common calibrators intended to transfer trueness from the top of the calibration hierarchy to commercial IVD calibrators, and (b) the measurement uncertainty (MU) of CRM certified values and the reproducibility characteristics of RMP measurements, considering their impact on the MU of clinical samples, when compared to maximum allowable MU (MAU). The discussion output is a recommendation for suppliers to respond urgently to the need to provide higher-order references (CRMs and/or RMPs) for a number of key analytes that are currently lacking or do not yet fully meet quality criteria related to: (a) commutability assessment, (b) contribution to MAU fulfilment, and (c) demonstration of the extent of equivalence to an already listed higher-order reference.
Collapse
Affiliation(s)
- Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Torun, Poland
| | - Robert Wielgosz
- Bureau International des Poids et Mésures (BIPM), Paris, France
| |
Collapse
|
6
|
Wadhwa N, Bhat K, Kalsi M, Sadhu T. Evaluation of Measurement Uncertainty in Clinical Chemistry and its Comparison With Analytical Performance Specifications. Cureus 2025; 17:e79043. [PMID: 40099095 PMCID: PMC11912806 DOI: 10.7759/cureus.79043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/15/2025] [Indexed: 03/19/2025] Open
Abstract
Introduction To evaluate the variability in values reported by a clinical laboratory, it is important to assess the measurement uncertainty (MU). Furthermore, verifying that the estimated MU aligns with relevant analytical performance specifications (APS) is essential. Previous research has indicated variability in how laboratories estimate and apply MU, with some failing to meet APS, potentially affecting clinical decision-making. Additionally, factors such as differences in instrumentation, reagent quality, and calibration protocols may contribute to regional variations in MU, emphasizing the need for a systematic evaluation. This study aimed to determine the MU of 31 measurands and compare it with the APS available in the literature to assess whether our measuring systems can meet these APS. Methods The study was conducted in the Clinical Biochemistry Laboratory of the Himalayan Institute of Medical Sciences, Dehradun, India. The measuring systems in our laboratory are Beckman Coulter DxC 700 AU (Beckman Coulter, Inc., Brea, California, United States), Beckman Coulter UniCel DxI 800 (Beckman Coulter, Inc.,), and bioMérieux VIDAS (bioMérieux SA, Marcy-l'Étoile, France). The 'top-down' approach which uses internal quality control data and calibrator information was used for the estimation of MU. The formula used was: u result =√(u cal 2 + u Rw 2+ u bias 2). Objectively derived APS available in the literature were utilized to determine the allowable MU. Results A total of 24 measurands exhibited uncertainty estimates below the minimum APS limits. However, serum lactate dehydrogenase (LD), creatine kinase (CK), alkaline phosphatase (ALP), sodium, chloride, glucose, and ferritin showed MU higher than the minimum APS. The calibrator uncertainties (ucal) for ALP (4.7), LD (5.45), CK (11.06), and Ferritin (23.2) were significantly high, contributing to their elevated MU estimates. Additionally, the minimum APS for serum chloride (0.74) and sodium (0.40) were particularly stringent and could not be met. Conclusion The evaluation of MU provides objective insights into the quality of measurement systems and, its comparison, against set APS, supports the applicability of laboratory results in clinical decision-making. Failing to meet APS can lead to misdiagnosis, treatment errors, and patient safety risks. It may also hinder ISO 15189 accreditation and increase retesting costs.
Collapse
Affiliation(s)
- Nishtha Wadhwa
- Biochemistry, Himalayan Institute of Medical Sciences, Dehradun, IND
| | - Kiran Bhat
- Biochemistry, Himalayan Institute of Medical Sciences, Dehradun, IND
| | - Mansi Kalsi
- Biochemistry, Himalayan Institute of Medical Sciences, Dehradun, IND
| | - Tushita Sadhu
- Biochemistry, Shri Guru Ram Rai Institute of Medical and Health Science, Dehradun, IND
| |
Collapse
|
7
|
Borrillo F, Panteghini M. An outline of measurement uncertainty of total protein in urine estimated according to the ISO Technical Specification 20914. Clin Chem Lab Med 2024; 62:e175-e177. [PMID: 38353161 DOI: 10.1515/cclm-2024-0064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 01/30/2024] [Indexed: 06/25/2024]
Affiliation(s)
| | - Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| |
Collapse
|
8
|
Panteghini M. Analytical performance specifications for combined uncertainty budget in the implementation of metrological traceability. Clin Chem Lab Med 2024; 62:1497-1504. [PMID: 38311825 DOI: 10.1515/cclm-2023-1325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/23/2024] [Indexed: 02/06/2024]
Abstract
In addition to the correct implementation of calibration traceability, the definition and fulfillment of maximum allowable measurement uncertainty (MAU) are essential in assuring that laboratory measurements are clinically usable. Across the entire calibration hierarchy, three major contributors to the measurement uncertainty (MU) budget are identified, starting with the higher-order reference providers, extending through the in vitro diagnostic (IVD) manufacturers and their processes for assigning calibrator values, and ending with medical laboratories generating the random variability of results reported to clinicians. To understand if it is possible to achieve MAU and, consequently, to fix the possible drawbacks, the definition of combined MU budget limits across the entire calibration hierarchy has a central role. In particular, quality specifications for MU of reference and commercial calibrator materials should be defined according to the MAU on clinical samples. All involved stakeholders (i.e., higher-order reference providers, IVD manufacturers, medical laboratories) should be prepared to improve their performance whenever the clinical application of the test is made questionable by the failure to achieve MAU.
Collapse
Affiliation(s)
- Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Torun, Poland
| |
Collapse
|
9
|
Sandberg S, Zima T, Panteghini M. Analytical performance specifications - moving from models to practical recommendations. Clin Chem Lab Med 2024; 62:1451-1454. [PMID: 38841878 DOI: 10.1515/cclm-2024-0661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2024]
Affiliation(s)
- Sverre Sandberg
- Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway
- Norwegian Porphyria Centre, Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen, Norway
- Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Tomas Zima
- Institute of Medical Chemistry and Laboratory Medicine, 1st Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
| | - Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Torun, Poland
| |
Collapse
|
10
|
Borrillo F, Panteghini M. State-of-the-art model for derivation of analytical performance specifications: how to define the highest level of analytical performance technically achievable. Clin Chem Lab Med 2024; 62:1490-1496. [PMID: 38353168 DOI: 10.1515/cclm-2023-1286] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Accepted: 01/24/2024] [Indexed: 06/25/2024]
Abstract
To be accurate and equivalent among assays, laboratory results should be traceable to higher-order references and their quality should fulfill maximum allowable measurement uncertainty (MU) as defined to fit the intended clinical use. Accordingly, laboratory professionals should estimate and validate MU of performed tests using appropriate analytical performance specifications (APS). Current consensus supports the derivation of APS by using one of the three models established by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Strategic Conference held in Milan in 2014. It is recognized that some models are better suited for certain measurands than for others and the attention should be primarily directed towards their biological and clinical characteristics. Among others, model 3 should reflect the state of the art of the measurements that can be defined as the best analytical performance that is technically achievable. Taking serum C-reactive protein and ferritin as examples, here we describe the theoretical premises and the experimental protocol to be used to derive APS for MU when a measurand is allocated to this model. Although the model lacks a direct relationship with clinical outcomes, useful information about the in vitro diagnostic medical device performance and the average quality of provided results may be obtained.
Collapse
Affiliation(s)
| | - Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| |
Collapse
|
11
|
Dong L, Zhang Y, Fu B, Swart C, Jiang H, Liu Y, Huggett J, Wielgosz R, Niu C, Li Q, Zhang Y, Park SR, Sui Z, Yu L, Liu Y, Xie Q, Zhang H, Yang Y, Dai X, Shi L, Yin Y, Fang X. Reliable biological and multi-omics research through biometrology. Anal Bioanal Chem 2024; 416:3645-3663. [PMID: 38507042 DOI: 10.1007/s00216-024-05239-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/28/2024] [Accepted: 03/04/2024] [Indexed: 03/22/2024]
Abstract
Metrology is the science of measurement and its applications, whereas biometrology is the science of biological measurement and its applications. Biometrology aims to achieve accuracy and consistency of biological measurements by focusing on the development of metrological traceability, biological reference measurement procedures, and reference materials. Irreproducibility of biological and multi-omics research results from different laboratories, platforms, and analysis methods is hampering the translation of research into clinical uses and can often be attributed to the lack of biologists' attention to the general principles of metrology. In this paper, the progresses of biometrology including metrology on nucleic acid, protein, and cell measurements and its impacts on the improvement of reliability and comparability in biological research are reviewed. Challenges in obtaining more reliable biological and multi-omics measurements due to the lack of primary reference measurement procedures and new standards for biological reference materials faced by biometrology are discussed. In the future, in addition to establishing reliable reference measurement procedures, developing reference materials from single or multiple parameters to multi-omics scale should be emphasized. Thinking in way of biometrology is warranted for facilitating the translation of high-throughput omics research into clinical practices.
Collapse
Affiliation(s)
- Lianhua Dong
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China.
| | - Yu Zhang
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | - Boqiang Fu
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | - Claudia Swart
- Physikalisch-Technische Bundesanstalt, 38116, Braunschweig, Germany
| | | | - Yahui Liu
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | - Jim Huggett
- National Measurement Laboratory at LGC (NML), Teddington, Middlesex, UK
| | - Robert Wielgosz
- Bureau International Des Poids Et Mesures (BIPM), Pavillon de Breteuil, 92312, Sèvres Cedex, France
| | - Chunyan Niu
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | - Qianyi Li
- BGI, BGI-Shenzhen, Shenzhen, 518083, China
| | - Yongzhuo Zhang
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | - Sang-Ryoul Park
- Korea Research Institute of Standards and Science, Daejeon, Republic of Korea
| | - Zhiwei Sui
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | - Lianchao Yu
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China
| | | | - Qing Xie
- BGI, BGI-Shenzhen, Shenzhen, 518083, China
| | - Hongfu Zhang
- BGI Genomics, BGI-Shenzhen, Shenzhen, 518083, China
| | | | - Xinhua Dai
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China.
| | - Leming Shi
- State Key Laboratory of Genetic Engineering, School of Life Sciences and Human Phenome Institute, Fudan University, Shanghai, 200438, China
| | - Ye Yin
- BGI, BGI-Shenzhen, Shenzhen, 518083, China.
| | - Xiang Fang
- Center for Advanced Measurement of Science, National Institute of Metrology, Beijing, 100029, China.
| |
Collapse
|
12
|
Schierscher T, Salzmann L, Singh N, Bachmann M, Kobel A, Wild J, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of phenobarbital in human serum and plasma. Clin Chem Lab Med 2024; 62:1314-1326. [PMID: 38407268 DOI: 10.1515/cclm-2023-1104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/12/2024] [Indexed: 02/27/2024]
Abstract
OBJECTIVES Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 μg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.
Collapse
Affiliation(s)
| | | | - Neeraj Singh
- 111618 Roche Diagnostics GmbH , Penzberg, Germany
| | | | - Anja Kobel
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | - Janik Wild
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | |
Collapse
|
13
|
Schierscher T, Salzmann L, Singh N, Wild J, Fischer V, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of zonisamide in human serum and plasma. Clin Chem Lab Med 2024; 62:1288-1300. [PMID: 38105272 DOI: 10.1515/cclm-2023-0736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 11/03/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVES To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 μg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.
Collapse
Affiliation(s)
| | | | | | - Janik Wild
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Schierscher T, Salzmann L, Singh N, Bachmann M, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma. Clin Chem Lab Med 2024; 62:1301-1313. [PMID: 38095314 DOI: 10.1515/cclm-2023-0943] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 11/14/2023] [Indexed: 05/30/2024]
Abstract
OBJECTIVES An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) was developed and validated to accurately measure serum and plasma concentrations of carbamazepine. METHODS Quantitative nuclear magnetic resonance (qNMR) spectroscopy was used to determine the absolute content of the reference material, ensuring its traceability to SI units. The separation of carbamazepine from potential interferences, whether known or unknown, was achieved using a C18 column. A protein precipitation protocol followed by a high dilution step was established for sample preparation. Assay validation and determination of measurement uncertainty were performed in accordance with the guidelines of the Clinical and Laboratory Standards Institute, the International Conference on Harmonization (ICH), and the Guide to the Expression of Uncertainty in Measurement (GUM). In order to demonstrate equivalence to the already existing RMP a method comparison study was performed. RESULTS The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of carbamazepine within the range of 0.800-18.0 μg/mL. Intermediate precision and repeatability (n=60 measurements) was found to be <1.6 % and <1.3 % over all concentration levels and independent from the matrix. The relative mean bias ranged from -0.1 to 0.6 % for native serum and from -0.3 to -0.1 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were found to be <1.8 % and <1.3 %, respectively. Method comparison showed a good agreement between the Joint Committee of Traceability in Laboratory Medicine (JCTLM) listed RMP and the candidate RMP resulting in a Passing-Bablok regression equation with a slope of 1.01 and an intercept of -0.01. The bias in the patient cohort was found to be 0.9 %. CONCLUSIONS We present a novel LC-MS/MS-based candidate RMP for carbamazepine in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.
Collapse
|
15
|
Schierscher T, Salzmann L, Singh N, Fischer V, Kobel A, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of primidone in human serum and plasma. Clin Chem Lab Med 2024; 62:1327-1338. [PMID: 38549258 DOI: 10.1515/cclm-2023-1032] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 03/12/2024] [Indexed: 05/30/2024]
Abstract
OBJECTIVES Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 μg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.
Collapse
Affiliation(s)
| | | | | | | | - Anja Kobel
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | |
Collapse
|
16
|
Schierscher T, Singh N, Kobel A, Wild J, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine-10,11-epoxide in human serum and plasma. Clin Chem Lab Med 2024; 62:1339-1351. [PMID: 38515344 DOI: 10.1515/cclm-2023-1045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 02/29/2024] [Indexed: 03/23/2024]
Abstract
OBJECTIVES A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 μg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.
Collapse
Affiliation(s)
| | - Neeraj Singh
- 111618 Roche Diagnostics GmbH , Penzberg, Germany
| | - Anja Kobel
- 58117 Dr. Risch Ostschweiz AG , Buchs, Switzerland
| | - Janik Wild
- 58117 Dr. Risch Ostschweiz AG , Buchs, Switzerland
| | | | | | - Lorenz Risch
- 58117 Dr. Risch Ostschweiz AG , Buchs, Switzerland
| | | | | | | |
Collapse
|
17
|
Van Hoovels L, Massa B, Stavelin A, De Meyer H, De Schrijver P, Van Laethem V, Barglazan D, Gruson D, Hopstaken R, Peeters B, Van Hoof V, Verdonck A, Verbakel JY. Analytical performance and user-friendliness of four commercially available point-of-care devices for C-reactive protein. Clin Chim Acta 2024; 560:119737. [PMID: 38768699 DOI: 10.1016/j.cca.2024.119737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 05/14/2024] [Accepted: 05/15/2024] [Indexed: 05/22/2024]
Abstract
INTRODUCTION Proper implementation of Point-of-Care testing (POCT) for C-reactive protein (CRP) in primary care can decrease the inappropriate use of antibiotics, thereby tackling the problem of growing antimicrobial resistance. OBJECTIVE The analytical performance and user-friendliness of four POCT-CRP assays were evaluated: QuikRead go easy, LumiraDx, cobas b 101 and Afinion 2. MATERIALS AND METHODS Imprecision was evaluated using plasma pools in addition to manufacturer-specific control material. Trueness was assessed by verification of traceability to ERM-DA474/IFCC in parallel to method comparison towards the central laboratory CRP method (cobas c 503) using i) retrospectively selected plasma samples (n = 100) and ii) prospectively collected capillary whole blood samples (n = 50). User-friendliness was examined using a questionnaire. RESULTS Between-day imprecision on plasma pools varied from 4.5 % (LumiraDx) to 11.5 % (QuikRead). Traceability verification revealed no significant difference between cobas c 503 CRP results and the ERM-DA474/IFCC certified value. cobas b 101 and Afinion achieved the best agreement with the central laboratory method. LumiraDx and QuikRead revealed a negative mean difference, with LumiraDx violating the criterion of > 95 % of POCT-CRP-results within ± 20 % of the comparison method. Regarding user-friendliness, Afinion obtained the highest Likert-scores. CONCLUSION The analytical performance and user-friendliness of POCT-CRP devices varies among manufacturers, emphasizing the need for quality assurance supervised by a central laboratory.
Collapse
Affiliation(s)
- Lieve Van Hoovels
- Department of Laboratory Medicine, OLV Hospital Aalst, Aalst, Belgium; Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium.
| | - Bo Massa
- Department of Laboratory Medicine, OLV Hospital Aalst, Aalst, Belgium; Department of Laboratory Medicine, University Hospital Leuven, Leuven, Belgium
| | - Anne Stavelin
- Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway
| | - Helene De Meyer
- Department of Laboratory Medicine, OLV Hospital Aalst, Aalst, Belgium
| | | | | | - Dragos Barglazan
- Laboratoire Hospitalier Universitaire de Bruxelles, Universitair Laboratorium Brussel (LHUB-ULB), Brussels, Belgium
| | - Damien Gruson
- Department of Medical Biochemistry, Clinique Saint-Luc, UCLouvain, Woluwe-Saint-Lambert, Belgium
| | | | - Bart Peeters
- Department of Laboratory Medicine, Heilig Hart Hospital Lier, Lier, Belgium
| | - Viviane Van Hoof
- Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Ann Verdonck
- Department of Laboratory Medicine, University Hospital Leuven, Leuven, Belgium
| | - Jan Y Verbakel
- EPI-Centre, Academisch Centrum Huisartsgeneeskunde, KU Leuven, Leuven, Belgium; NIHR Community Healthcare Medtech and IVD cooperative, Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
18
|
Sonntag O, Loh TP. Calibración, un componente subestimado del proceso analítico en el laboratorio clínico. ADVANCES IN LABORATORY MEDICINE 2024; 5:153-158. [PMID: 38939209 PMCID: PMC11206177 DOI: 10.1515/almed-2023-0147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 10/12/2023] [Indexed: 06/29/2024]
Abstract
En el laboratorio clínico, la calibración de los procedimientos de medición es un aspecto clave a la hora de garantizar la fiabilidad de los resultados del paciente. A lo largo de los años, se han publicado multitud de publicaciones y procedimientos para la evaluación del control de calidad y la interpretación de sus resultados. En esta publicación, nos centraremos en un aspecto crítico, la calibración, ya que no existen publicaciones o directrices claras sobre metodologías de calibración. Por lo general, solo están disponibles las recomendaciones del fabricante del reactivo o instrumento. El propósito de esta revisión es ahondar en esta deficiencia, con el fin de suscitar un debate y mejorar la situación actual.
Collapse
Affiliation(s)
| | - Tze Ping Loh
- Consultor Senior, División de Química Clínica, Departamento de Medicina de Laboratorio, Hospital Nacional Universitario, Singapore, Singapore
| |
Collapse
|
19
|
Sonntag O, Loh TP. Calibration - an under-appreciated component in the analytical process of the medical laboratories. ADVANCES IN LABORATORY MEDICINE 2024; 5:148-152. [PMID: 38939195 PMCID: PMC11206179 DOI: 10.1515/almed-2023-0127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 10/12/2023] [Indexed: 06/29/2024]
Abstract
Calibration of an analytical measurement procedure is an important basis for the reliability of patient results. Many publications and as well as procedures on how to estimate quality control and interpret those results have been become available over the years. In this publication we are focusing on the critical part of the calibration as there are no clear communication or guidelines on how to perform it. Usually only the recommendation of the reagent or instrument manufacturer is available. We would like to point out this gap to invite for a discussion and improvement of the current situation.
Collapse
Affiliation(s)
| | - Tze Ping Loh
- Clinical Chemistry Division, Department of Laboratory Medicine, National University Hospital, Singapore, Singapore
| |
Collapse
|
20
|
Rigo-Bonnin R, Mas-Bosch V, Canalias F. Measurement uncertainty estimation of free drug concentrations in clinical laboratories using equilibrium dialysis. Clin Chem Lab Med 2024; 62:870-880. [PMID: 38050372 DOI: 10.1515/cclm-2023-1023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 11/20/2023] [Indexed: 12/06/2023]
Abstract
OBJECTIVES Developing procedures based on equilibrium dialysis (ED) that allow measuring the free drug concentration in plasma improves therapeutic drug monitoring (TDM) in those cases where its measurement is justified. However, this procedure requires specific sample preparation and presents different pitfalls, which are not error-free. As with any result provided by a clinical laboratory, this one should be as accurate as possible to allow a correct clinical interpretation. The measurement uncertainty (MU) is a parameter that enables the accuracy of results to be known, and that is mandated by ISO 15189. Herein, this study suggests how the MU for the results of the free drug concentrations in serum could be estimated when an ED is used. METHODS A combination of the top-down and bottom-up approaches was used to estimate the MU based on the ISO/TS 20914:2019 and JCGM 100:2008 guidelines, including the concentration of free phenytoin in serum, as an example. Different scenarios were incorporated considering or not a significant bias related to the primary drawbacks of ED: the non-specific binding, the volume shift effect and the Gibbs-Donnan effect. RESULTS The expanded uncertainties estimated ranged between 13.0 and 30.9 %. The highest MU corresponded to the free drug concentrations in serum results when significant biases related to the volume shift and Gibbs-Donnan effects exist. CONCLUSIONS A detailed estimation of MU for free drug concentrations is presented using ED, considering different scenarios. This study could stimulate clinical laboratories to perform MU studies and its application in TDM.
Collapse
Affiliation(s)
- Raúl Rigo-Bonnin
- Laboratori Clínic, IDIBELL, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Barcelona, Spain
| | - Virgínia Mas-Bosch
- Laboratori Clínic, IDIBELL, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Barcelona, Spain
| | - Francesca Canalias
- Departament de Bioquímica i Biologia Molecular, Laboratori de Referència d'Enzimologia Clínica, Universitat Autònoma de Barcelona, Bellaterra, Spain
| |
Collapse
|
21
|
Cattaneo D, Panteghini M. Analytical performance specifications for measurement uncertainty in therapeutic monitoring of immunosuppressive drugs. Clin Chem Lab Med 2024; 62:e81-e83. [PMID: 37855255 DOI: 10.1515/cclm-2023-1063] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 10/09/2023] [Indexed: 10/20/2023]
Affiliation(s)
- Dario Cattaneo
- Department of Infectious Diseases, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Mauro Panteghini
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
22
|
Çubukçu HC, Vanstapel F, Thelen M, van Schrojenstein Lantman M, Bernabeu-Andreu FA, Meško Brguljan P, Milinkovic N, Linko S, Panteghini M, Boursier G. APS calculator: a data-driven tool for setting outcome-based analytical performance specifications for measurement uncertainty using specific clinical requirements and population data. Clin Chem Lab Med 2024; 62:597-607. [PMID: 37978287 DOI: 10.1515/cclm-2023-0740] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 10/18/2023] [Indexed: 11/19/2023]
Abstract
OBJECTIVES According to ISO 15189:2022, analytical performance specifications (APS) should relate to intended clinical use and impact on patient care. Therefore, we aimed to develop a web application for laboratory professionals to calculate APS based on a simulation of the impact of measurement uncertainty (MU) on the outcome using the chosen decision limits, agreement thresholds, and data of the population of interest. METHODS We developed the "APS Calculator" allowing users to upload and select data of concern, specify decision limits and agreement thresholds, and conduct simulations to determine APS for MU. The simulation involved categorizing original measurand concentrations, generating measured (simulated) results by introducing different degrees of MU, and recategorizing measured concentrations based on clinical decision limits and acceptable clinical misclassification rates. The agreements between original and simulated result categories were assessed, and values that met or exceeded user-specified agreement thresholds that set goals for the between-category agreement were considered acceptable. The application generates contour plots of agreement rates and corresponding MU values. We tested the application using National Health and Nutrition Examination Survey data, with decision limits from relevant guidelines. RESULTS We determined APS for MU of six measurands (blood total hemoglobin, plasma fasting glucose, serum total and high-density lipoprotein cholesterol, triglycerides, and total folate) to demonstrate the potential of the application to generate APS. CONCLUSIONS The developed data-driven web application offers a flexible tool for laboratory professionals to calculate APS for MU using their chosen decision limits and agreement thresholds, and the data of the population of interest.
Collapse
Affiliation(s)
- Hikmet Can Çubukçu
- General Directorate of Health Services, Rare Diseases Department, Turkish Ministry of Health, Ankara, Türkiye
- Hacettepe University Institute of Informatics, Ankara, Türkiye
| | - Florent Vanstapel
- Laboratory Medicine, University Hospital Leuven, Leuven, Belgium
- Department of Public Health, Biomedical Sciences Group, Catholic University Leuven, Leuven, Belgium
| | - Marc Thelen
- SKML, Foundation for Quality Assurance in Laboratory Medicine, Nijmegen, The Netherlands
- Department of Laboratory Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Marith van Schrojenstein Lantman
- SKML, Foundation for Quality Assurance in Laboratory Medicine, Nijmegen, The Netherlands
- Department of Laboratory Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
- Result Laboratory for Clinical Chemistry, Amphia Hospital Breda, Breda, The Netherlands
| | | | - Pika Meško Brguljan
- Department of Clinical Chemistry, University Clinic for Respiratory and Allergic Deseases, Golnik, Slovenia
| | - Neda Milinkovic
- Department of Medical Biochemistry, Faculty of Pharmacy, University of Belgrade, Belgrade, Serbia
| | | | - Mauro Panteghini
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Guilaine Boursier
- Department of Molecular Genetics and Cytogenomics, Rare Diseases and Autoinflammatory Unit, CHU Montpellier, University of Montpellier, Montpellier, France
| |
Collapse
|
23
|
Borrillo F, Capoferri A, Rovegno L, Panteghini M. Closed analyser lids do not reduce the measurement uncertainty of serum total carbon dioxide. Ann Clin Biochem 2024; 61:154-155. [PMID: 37978867 DOI: 10.1177/00045632231216598] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Affiliation(s)
| | | | - Leila Rovegno
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milano, Italy
| | - Mauro Panteghini
- Department of Laboratory Medicine, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Poland
| |
Collapse
|
24
|
Rovegno L, Civera E, Infusino I, Panteghini M. State of the art of measurement uncertainty of serum ferritin. Clin Chem Lab Med 2024; 62:e6-e8. [PMID: 37466239 DOI: 10.1515/cclm-2023-0711] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 07/07/2023] [Indexed: 07/20/2023]
Affiliation(s)
- Leila Rovegno
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milano, Milan, Italy
| | - Elisa Civera
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milano, Milan, Italy
| | - Ilenia Infusino
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milano, Milan, Italy
| | - Mauro Panteghini
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
25
|
Bianchi G, Frusciante E, Colombo G, Infusino I, Aloisio E, Panteghini M. Validation of metrological traceability of the new generation of Abbott Alinity alkaline phosphatase assay. Clin Chem Lab Med 2024; 62:280-287. [PMID: 37614121 DOI: 10.1515/cclm-2023-0553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 08/06/2023] [Indexed: 08/25/2023]
Abstract
OBJECTIVES Recently, Abbott Diagnostics marketed a new generation of Alinity enzyme assays, introducing a multiparametric calibrator [Consolidated Chemistry Calibrator (ConCC)] in place of or in addition to factor-based calibrations. For alkaline phosphatase (ALP), both calibration options are offered, i.e., with ConCC (ALP2) and with an experimental calibration factor (ALP2F). Both options are declared traceable to the 2011 IFCC reference measurement procedure (RMP). Before to replace the old generation (ALP1) with the new one, we decided to validate the trueness of ALP2/ALP2F. METHODS Three approaches were employed: (a) preliminary comparison on 48 native frozen serum samples with ALP1, of which traceability to RMP was previously successfully verified; (b) examination of three banked serum pools (BSP) with values assigned by RMP; (c) direct comparison with RMP on a set of 24 fresh serum samples. Bias estimation and regression studies were performed, and the standard measurement uncertainty associated with ALP measurements on clinical samples (uresult) was estimated and compared with established analytical performance specifications (APS). ConCC commutability was also assessed. RESULTS A positive proportional bias was found with both ALP2 and ALP2F when compared to ALP1 and RMP. This positive bias was confirmed on BSP: in average, +13.1 % for ALP2 and +10.0 % for ALP2F, respectively. uresult were 13.28 % for ALP2 and 10.04 % for ALP2F, both not fulfilling the minimum APS of 4.0 %. Furthermore, ConCC was not commutable with clinical samples. CONCLUSIONS Our results unearth problems in the correct implementation of traceability of Alinity ALP2/ALP2F, with the risk for the new assay to be unfit for clinical purposes.
Collapse
Affiliation(s)
- Giorgia Bianchi
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Erika Frusciante
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Giulia Colombo
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Ilenia Infusino
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Elena Aloisio
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Mauro Panteghini
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
26
|
Metsu D, Mille D, Pailly C, Oancea VG, Essemilaire L, Coppin D. Analytical assays and bootstrap resampling method to validate performance of the Roche Elecsys STAT highly sensitive troponin T assay and its application for the 'rule-out' part of ESC guidelines for NTSTEMI. Ann Clin Biochem 2024; 61:63-69. [PMID: 37525403 DOI: 10.1177/00045632231194449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
BACKGROUND The European Society of Cardiology (ESC) guidelines recommend a dynamic (0-1h) cardiac troponin (cTn) determination for non-ST elevation myocardial infarction diagnosis. For patients with low cTn levels, a discharge from emergency can be considered. Nevertheless, cTn cutoffs for discharge are lower than the limits of quantification proposed by laboratory reagent suppliers. AIM Validate cTn assay on the Elecsys STAT kit. MATERIALS AND METHODS Precision, trueness, repeatability and within-laboratory variability were calculated from internal quality control and plasma pooled at 5.78 and 10.73 ng/L. Accuracy was calculated from external quality control. Uncertainty of measurement was calculated from (i) the uncertainty of the standard and control values and (ii) by precision from pooled plasma. Distribution of precision results from pooled plasma has been evaluated by bootstrap simulations. Dilution linearity tests with patient plasma were performed to evaluate the method for values near 5 ng/L. RESULTS Precision and trueness ranged from 1.35 to 4.45% and from 0.14 to -3.74%, respectively. Accuracy results ranged from 101.40 to 104.90%. Within laboratory variability was 2.91%. Uncertainty ranged from 3.66% to 19.90% for higher (2188) to lower values (5.78 ng/L). Bootstrap simulations allowed utilization of precision data from pooled plasma to evaluate cTn assay. The method was linear from 4.48 to 39.80 ng/L. A linear regression model best described the data. CONCLUSION Elecsys STAT method provides accurate cTn results, including patients with cTn results categorizing them as 'rule-out' in the ESC guidelines.
Collapse
Affiliation(s)
- David Metsu
- Department of Laboratory Medicine, Montauban Hospital, Montauban, France
| | - Daphné Mille
- Department of Emergency Medicine, Montauban Hospital, Montauban, France
| | - Carole Pailly
- Department of Emergency Medicine, Montauban Hospital, Montauban, France
| | - Valerica G Oancea
- Department of Laboratory Medicine, Montauban Hospital, Montauban, France
- Université Toulouse III, Toulouse University Hospital, Toulouse, France
| | - Luc Essemilaire
- Accredited Medical Laboratories Network (LABAC), Lyon, France
| | - Dominique Coppin
- Department of Emergency Medicine, Montauban Hospital, Montauban, France
| |
Collapse
|
27
|
Kobel A, Schierscher T, Singh N, Salzmann L, Liesch F, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of levetiracetam in human serum and plasma. Clin Chem Lab Med 2023; 61:1967-1977. [PMID: 37011038 DOI: 10.1515/cclm-2022-1038] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 03/14/2023] [Indexed: 04/04/2023]
Abstract
OBJECTIVES To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma. METHODS Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation. Spiked matrix samples of serum and plasma were used to test selectivity and specificity. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Precision and accuracy were evaluated over 5 days. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of levetiracetam within the range of 1.53-90.0 μg/mL. Intermediate precision was <2.2% and repeatability was 1.1-1.7% across all concentrations. The relative mean bias ranged from -2.5% to -0.3% across all levels and matrices within the measuring range. Diluted samples were found with a mean bias ranging from -0.1 to 2.9%. The predefined acceptance criterion for measurement uncertainty was met and determined for individual measurements independently of the concentration level and sample type to be ≤4.0% (k=2). CONCLUSIONS We present a novel LC-MS/MS)-based candidate RMP for levetiracetam in human serum and plasma. Its expanded measurement uncertainty of ≤4.0% meets the clinical needs in levetiracetam monitoring. Utilizing qNMR to characterize levetiracetam reference materials allowed metrological traceability to SI units.
Collapse
Affiliation(s)
- Anja Kobel
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Salzmann L, Spescha T, Singh N, Kobel A, Fischer V, Schierscher T, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of topiramate in human serum and plasma. Clin Chem Lab Med 2023; 61:1942-1954. [PMID: 37466369 DOI: 10.1515/cclm-2022-1273] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 07/05/2023] [Indexed: 07/20/2023]
Abstract
OBJECTIVES Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS The method enabled topiramate quantification within the range of 1.20-36.0 μg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.
Collapse
Affiliation(s)
| | | | | | - Anja Kobel
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Salzmann L, Wild J, Singh N, Schierscher T, Liesch F, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma. Clin Chem Lab Med 2023; 61:1955-1966. [PMID: 36689915 DOI: 10.1515/cclm-2022-0998] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/23/2022] [Indexed: 01/24/2023]
Abstract
OBJECTIVES To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations. METHODS A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. ID-LC-MS/MS parameters evaluated included selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement. RESULTS The use of qNMR provided traceability to International System (SI) units. The chromatographic assay was highly selective, allowing baseline separation of gabapentin and the gabapentin-lactam impurity, without observable matrix effects. Variability between injections, preparations, calibrations, and days (intermediate precision) was <2.3%, independent of the matrix, while the coefficient of variation for repeatability was 0.9-2.0% across all concentration levels. The relative mean bias ranged from -0.8-1.0% for serum and plasma samples. Passing-Bablok regression analysis indicated very good inter-laboratory agreement; the slope was 1.00 (95% confidence interval [CI] 0.98 to 1.03) and the intercept was -0.05 (95% CI -0.14 to 0.03). Pearson's correlation coefficient was ≥0.996. Expanded measurement uncertainties for single measurements were found to be ≤5.0% (k=2). CONCLUSIONS This analytical protocol for gabapentin, utilizing traceable and selective qNMR and ID-LC-MS/MS techniques, allows for the standardization of routine tests and the reliable evaluation of clinical samples.
Collapse
Affiliation(s)
| | - Janik Wild
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Salzmann L, Spescha T, Singh N, Schierscher T, Bachmann M, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma. Clin Chem Lab Med 2023; 61:1930-1941. [PMID: 36785916 DOI: 10.1515/cclm-2022-0997] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 02/02/2023] [Indexed: 02/15/2023]
Abstract
OBJECTIVES We developed an isotope dilution (ID)-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for lamotrigine in human serum and plasma, using quantitative nuclear magnetic resonance-characterized reference standards to ensure traceability to the International System of Units. METHODS A sample preparation protocol based on protein precipitation combined with LC-MS/MS analysis using a C18 column for chromatographic separation was established for the quantification of lamotrigine in human serum and plasma. Assay validation was performed according to current guidelines. Spiked serum and plasma samples were used to assess selectivity and specificity; a post-column infusion experiment and comparison of standard line slopes were performed to ascertain possible matrix effects. Precision and accuracy were determined in a 5 days validation experiment. Measurement uncertainty was determined per the Guide to the Expression of Uncertainty in Measurement. RESULTS The method allowed the quantification of lamotrigine in serum and plasma in a range of 0.600-24.0 μg/mL without any observable matrix effects. The relative mean bias (n=6) ranged from 1.7 to 3.7%; intermediate precision, including variances in between-day, -calibration, and -injection, was ≤2.4%, independent of the level and matrix. Total measurement uncertainty for a single measurement was ≤2.6%; expanded uncertainty was ≤5.2% (coverage factor k=2). CONCLUSIONS This candidate RMP based on ID-LC-MS/MS provides a traceable and reliable platform for the standardization of routine assays and the evaluation of clinical samples.
Collapse
|
31
|
Schäffler J, Habler K, Vogeser M. A suggested protocol for value assignment using isotope-dilution-LC-MS/MS in reference measurement procedures - Exemplary application for ciprofloxacin in serum. Clin Chim Acta 2023; 549:117556. [PMID: 37709112 DOI: 10.1016/j.cca.2023.117556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 09/11/2023] [Accepted: 09/11/2023] [Indexed: 09/16/2023]
Abstract
BACKGROUND Reference measurement procedures for assigning values to calibration materials play a crucial role in the concept of metrological traceability in laboratory medicine. ISO standard 15,193 specifies the requirements for such measurement procedures, albeit in a very general terms. MATERIALS AND METHODS A standard structure of analysis series for value assignment by LC-MS/MS was developed and tested,this structure was complemented by a spreadsheet file for result calculation, metadata evaluation, and finally validation and confirmation of individual analysis runs and individual results, and measurement uncertainty evaluation. This framework was applied to a procedure for the quantification of ciprofloxacin in serum as an example. RESULTS The approach of a detailed description of the analytical procedures of isotope dilution LC-MS/MS reference measurement methods together with a highly standardized spreadsheet-based method for data processing was found to be practical and efficient. The described measurement procedure for the quantification of ciprofloxacin in serum was found to be fit for purpose. CONCLUSION A standardized, detailed procedure for the application of isotope dilution LC-MS/MS in reference measurement procedures can complement the ISO 15193 standard with respect to this particular analytical technique, which is now widely used in the context of metrological traceability in laboratory medicine.
Collapse
Affiliation(s)
- Judith Schäffler
- Institute of Laboratory Medicine, University Hospital, LMU Munich, Germany
| | - Katharina Habler
- Institute of Laboratory Medicine, University Hospital, LMU Munich, Germany
| | - Michael Vogeser
- Institute of Laboratory Medicine, University Hospital, LMU Munich, Germany.
| |
Collapse
|
32
|
Borrillo F, Panteghini M. Current performance of C-reactive protein determination and derivation of quality specifications for its measurement uncertainty. Clin Chem Lab Med 2023; 61:1552-1557. [PMID: 36773318 DOI: 10.1515/cclm-2023-0069] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 01/31/2023] [Indexed: 02/13/2023]
Abstract
From External Quality Assessment data, current harmonization of CRP measuring systems appears to be satisfactory, the inter-assay CV being well below 10%. The inter-method variability is even better (close to 3%) when the widely used measuring systems are compared at CRP concentrations employed as cut-off for detecting sub-clinical infection (i.e., 10.0 mg/L) and measurement variability estimated, according to ISO 20914:2019 Technical Specification, from the intermediate within-lab reproducibility of 6-month consecutive measurement data. According to the state-of-the-art model (which is better suited for CRP), the maximum allowable measurement uncertainty (MAU) for CRP measurement on clinical samples with 10.0 mg/L concentrations is 3.76% (desirable quality). As measurement uncertainty (MU) of the only available reference material (ERM-DA474/IFCC) is ∼3%, to fulfil desirable MAU on clinical samples, IVD manufacturers should work to keep the contribution of remaining MU sources (commercial calibrator and intermediate within-lab reproducibility) lower than 2.3%.
Collapse
Affiliation(s)
- Francesca Borrillo
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mauro Panteghini
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
33
|
Aloisio E, Colombo G, Dolci A, Panteghini M. C-reactive protein and clinical outcome in COVID-19 patients: the importance of harmonized measurements. Clin Chem Lab Med 2023; 61:1546-1551. [PMID: 37036741 DOI: 10.1515/cclm-2023-0276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 03/30/2023] [Indexed: 04/11/2023]
Abstract
C-reactive protein (CRP) is a cytokine-mediated acute phase reactant with a recognized role in inflammatory conditions and infectious disease. In coronavirus disease 2019 (COVID-19), elevated CRP concentrations in serum were frequently detected and significantly associated with poor outcome in terms of disease severity, need for intensive care, and in-hospital death. For these reasons, the marker was proposed as a powerful test for prognostic classification of COVID-19 patients. In most of available publications, there was however confounding information about how interpretative criteria for CRP in COVID-19 should be derived, including quality of employed assays and optimal cut-off definition. Assuring result harmonization and controlling measurement uncertainty in terms of performance specifications are fundamental to allow worldwide application of clinical information according to specific CRP thresholds and to avoid risk of patient misclassification.
Collapse
|
34
|
Panteghini M. Evaluating and monitoring analytical quality by internal quality control. Clin Biochem 2023; 118:110594. [PMID: 37271492 DOI: 10.1016/j.clinbiochem.2023.110594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/27/2023] [Accepted: 05/30/2023] [Indexed: 06/06/2023]
Affiliation(s)
- Mauro Panteghini
- Research Center for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milano, Italy.
| |
Collapse
|
35
|
Borrillo F, Pasqualetti S, Panteghini M. Measurement Uncertainty of Thyroid Function Tests on a Chemiluminescent Microparticle Immunoassay System Needs to Be Improved. J Appl Lab Med 2023; 8:420-422. [PMID: 36645382 DOI: 10.1093/jalm/jfac132] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Francesca Borrillo
- Research Center for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Sara Pasqualetti
- Research Center for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mauro Panteghini
- Research Center for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
36
|
Krintus M, Panteghini M. Judging the clinical suitability of analytical performance of cardiac troponin assays. Clin Chem Lab Med 2023; 61:801-810. [PMID: 36798043 DOI: 10.1515/cclm-2023-0027] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 02/07/2023] [Indexed: 02/18/2023]
Abstract
New millennium diagnostic criteria for acute myocardial infarction precipitated a revolutionary shift from an approach based primarily on electrocardiography and clinical symptoms to a strategy based on biomarkers, and preferably cardiac troponins (cTn) I and T. In the last 20 years, clinical recommendations have strengthened the role of cTn and led to the development of highly sensitive (hs-cTn) assays, which are now leading players in all current clinical practice guidelines. To optimize the clinical use of these hs-cTn assays, focus on their analytical aspects has become increasingly important, emphasizing the need for the establishment of suitable analytical performance by the definition and implementation of appropriate specifications. An accurate estimate of measurement uncertainty, together with the acquisition of the highest analytical quality when very low concentrations of hs-cTn are measured, are essential requirements and should represent a practical laboratory standard in assuring optimal clinical use. Additional goals for further improving the quality of laboratory information should be the establishment of robust data concerning biological variation of cTn and the resolution of practical challenges opposed to the harmonization of cTn I results obtained by differing commercial measuring systems.
Collapse
Affiliation(s)
- Magdalena Krintus
- Department of Laboratory Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Torun, Poland
| | - Mauro Panteghini
- Department of Biomedical and Clinical Sciences, University of Milan, Milano, Italy
| |
Collapse
|
37
|
Rotgers E, Linko S, Theodorsson E, Kouri TT. Clinical decision limits as criteria for setting analytical performance specifications for laboratory tests. Clin Chim Acta 2023; 540:117233. [PMID: 36693582 DOI: 10.1016/j.cca.2023.117233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 01/17/2023] [Accepted: 01/18/2023] [Indexed: 01/22/2023]
Abstract
BACKGROUND The biological (CVI), preanalytical (CVPRE), and analytical variation (CVA) are inherent to clinical laboratory testing and consequently, interpretation of clinical test results. METHODS The sum of the CVI, CVPRE, and CVA, called diagnostic variation (CVD), was used to derive clinically acceptable analytical performance specifications (CAAPS) for clinical chemistry measurands. The reference change concept was applied to clinically significant differences (CD) between two measurements, with the formula CD = z*√2* CVD. CD for six measurands were sought from international guidelines. The CAAPS were calculated by subtracting variances of CVI and CVPRE from CVD. Modified formulae were applied to consider statistical power (1-β) and repeated measurements. RESULTS The obtained CAAPS were 44.9% for urine albumin, 0.6% for plasma sodium, 22.9% for plasma pancreatic amylase, and 8.0% for plasma creatinine (z = 3, α = 2.5%, 1-β = 85%). For blood HbA1c and plasma low-density lipoprotein cholesterol, replicate measurements were necessary to reach CAAPS for patient monitoring. The derived CAAPS were compared with analytical performance specifications, APS, based on biological variation. CONCLUSIONS The CAAPS models pose a new tool for assessing APS in a clinical laboratory. Their usability depends on the relevance of CD limits, required statistical power and the feasibility of repeated measurements.
Collapse
Affiliation(s)
- Emmi Rotgers
- Department of Clinical Chemistry, University of Helsinki, and HUSLAB, HUS Diagnostic Center, Helsinki University Hospital, FIN-00029 Helsinki, Finland
| | | | - Elvar Theodorsson
- Department of Biomedical and Clinical Sciences, Division of Clinical Chemistry and Pharmacology, Linkoping University, SE-58183 Linkoping, Sweden
| | - Timo T Kouri
- Department of Clinical Chemistry, University of Helsinki, and HUSLAB, HUS Diagnostic Center, Helsinki University Hospital, FIN-00029 Helsinki, Finland.
| |
Collapse
|
38
|
Braga F, Pasqualetti S, Borrillo F, Capoferri A, Chibireva M, Rovegno L, Panteghini M. Definition and application of performance specifications for measurement uncertainty of 23 common laboratory tests: linking theory to daily practice. Clin Chem Lab Med 2023; 61:213-223. [PMID: 36282875 DOI: 10.1515/cclm-2022-0806] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 09/30/2022] [Indexed: 12/15/2022]
Abstract
Laboratories should estimate and validate [using analytical performance specifications (APS)] the measurement uncertainty (MU) of performed tests. It is therefore essential to appropriately define APS for MU, but also to provide a perspective on suitability of the practical application of these APS. In this study, 23 commonly ordered measurands were allocated to the models defined during the 2014 EFLM Strategic Conference to derive APS for MU. Then, we checked if the performance of commercial measuring systems used in our laboratory may achieve them. Most measurands (serum alkaline phosphatase, aspartate aminotransferase, creatine kinase, γ-glutamyltransferase, lactate dehydrogenase, pancreatic amylase, total proteins, immunoglobulin G, A, M, magnesium, urate, and prostate-specific antigen, plasma homocysteine, and blood red and white cells) were allocated to the biological variation (BV) model and desirable APS were defined accordingly (2.65%, 4.75%, 7.25%, 4.45%, 2.60%, 3.15%, 1.30%, 2.20%, 2.50%, 2.95%, 1.44%, 4.16%, 3.40%, 3.52%, 1.55%, and 5.65%, respectively). Desirable APS for serum total cholesterol (3.00%) and urine albumin (9.00%) were derived using outcome-based model. Lacking outcome-based information, serum albumin, high-density lipoprotein cholesterol, triglycerides, and blood platelets were temporarily reallocated to BV model, the corresponding desirable APS being 1.25%, 2.84%, 9.90%, and 4.85%, respectively. A mix between the two previous models was employed for serum digoxin, with a 6.00% desirable APS. In daily practice by using our laboratory systems, 16 tests fulfilled desirable and five minimum APS, while two (serum albumin and plasma homocysteine) exceeded goals, needing improvements.
Collapse
Affiliation(s)
- Federica Braga
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Sara Pasqualetti
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | | | - Alessia Capoferri
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mariia Chibireva
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Leila Rovegno
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mauro Panteghini
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
39
|
Panteghini M. Redesigning the surveillance of in vitro diagnostic medical devices and of medical laboratory performance by quality control in the traceability era. Clin Chem Lab Med 2022; 61:759-768. [PMID: 36542481 DOI: 10.1515/cclm-2022-1257] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 12/12/2022] [Indexed: 12/24/2022]
Abstract
Abstract
IVD manufacturers have total responsibility in terms of the traceability of marketed in vitro diagnostic medical devices (IVD-MD). This includes the provision of a quality control (QC) material as a part of the measuring system, suitable for traceability verification and alignment surveillance by end-users in daily practice. This material [to be used for the internal QC (IQC) component I as described in this paper] should have unbiased target values and an acceptability range corresponding to analytical performance specifications (APS) for suitable (expanded) measurement uncertainty (MU) on clinical samples. On the other hand, medical laboratories (by the IQC component II as described in this paper) should improve the IQC process and its judging criteria to establish a direct link between their performance, estimated as MU of provided results, and APS defined according to recommended models to apply corrective actions if the performance is worsening with the risk to jeopardize the clinical validity of test results. The participation to external quality assessment (EQA) programs that meet specific metrological criteria is also central to the evaluation of performance of IVD-MDs and of medical laboratories in terms of harmonization and clinical suitability of their measurements. In addition to the use of commutable materials, in this type of EQA it is necessary to assign values to them with selected reference procedures and to define and apply maximum allowable APS to substantiate the suitability of laboratory measurements in the clinical setting.
Collapse
Affiliation(s)
- Mauro Panteghini
- Centre for Metrological Traceability in Laboratory Medicine (CIRME) , University of Milan , Milano , Italy
| |
Collapse
|
40
|
Farré-Segura J, Le Goff C, Lukas P, Cobraiville G, Fillet M, Servais AC, Delanaye P, Cavalier E. Validation of an LC-MS/MS Method Using Solid-Phase Extraction for the Quantification of 1-84 Parathyroid Hormone: Toward a Candidate Reference Measurement Procedure. Clin Chem 2022; 68:1399-1409. [PMID: 36056745 DOI: 10.1093/clinchem/hvac135] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 07/05/2022] [Indexed: 11/12/2022]
Abstract
BACKGROUND Parathyroid hormone (PTH) measurement is important for patients with disorders of calcium metabolism, including those needing bone-turnover monitoring due to chronic kidney disease-mineral bone disorder. There are currently 2 generations of PTH immunoassays on the market, both having cross-reactivity issues and lacking standardization. Therefore, we developed an LC-MS/MS higher-order method for PTH analysis. METHODS The method was calibrated against the international standard for 1-84 PTH (WHO 95/646). Antibody-free sample preparation with the addition of an isotope-labeled internal standard was performed by solid-phase extraction. Extracts were analyzed by LC-MS/MS. EDTA-K2 plasma was used throughout the development and validation. Bias and uncertainty sources were tested according to ISO 15193. Clinical Laboratory Standards Institute guidelines and reference measurement procedures were consulted for the design of the validation. Patient samples and external quality controls were compared between LC-MS/MS and 2 third-generation immunoassays. RESULTS The method was validated for 1-84 PTH from 5.7 to 872.6 pg/mL. The interassay imprecision was between 1.2% and 3.9%, and the accuracy ranged from 96.2% to 103.2%. The measurement uncertainty was <5.6%. The comparison between LC-MS/MS and the immunoassays showed a proportional bias but moderate to substantial correlation between methods. CONCLUSIONS This LC-MS/MS method, which is independent of antibodies, is suitable for a wide range of PTH concentrations. The obtained analytical performance specifications demonstrate that development of a reference measurement procedure will be possible once a higher order reference standard is available.
Collapse
Affiliation(s)
- Jordi Farré-Segura
- Department of Clinical Chemistry, University of Liège (ULiège), CHU de Liège, Liège, Belgium
| | - Caroline Le Goff
- Department of Clinical Chemistry, University of Liège (ULiège), CHU de Liège, Liège, Belgium
| | - Pierre Lukas
- Department of Clinical Chemistry, University of Liège (ULiège), CHU de Liège, Liège, Belgium
| | - Gaël Cobraiville
- Laboratory for the Analysis of Medicines, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège (ULiège), Liège, Belgium
| | - Marianne Fillet
- Laboratory for the Analysis of Medicines, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège (ULiège), Liège, Belgium
| | - Anne-Catherine Servais
- Laboratory for the Analysis of Medicines, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège (ULiège), Liège, Belgium
| | - Pierre Delanaye
- Department of Nephrology-Dialysis-Transplantation, University of Liège (ULiège), CHU Liège, Liège, Belgium
- Department of Nephrology-Dialysis-Apheresis, Hôpital Universitaire Carémeau, Nîmes, France
| | - Etienne Cavalier
- Department of Clinical Chemistry, University of Liège (ULiège), CHU de Liège, Liège, Belgium
| |
Collapse
|
41
|
Gu H, Lee J, Hong J, Lee W, Yun YM, Chun S, Lee WI, Min WK. Practical Considerations for Clinical Laboratories in Top-down Approach for Assessing the Measurement Uncertainty of Clinical Chemistry Analytes. Ann Lab Med 2022; 42:630-637. [PMID: 35765871 PMCID: PMC9277045 DOI: 10.3343/alm.2022.42.6.630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 03/22/2022] [Accepted: 06/20/2022] [Indexed: 11/23/2022] Open
Abstract
Background The top-down (TD) approach using internal quality control (IQC) data is regarded a practical method for estimating measurement uncertainty (MU) in clinical laboratories. We estimated the MU of 14 clinical chemistry analytes using the TD approach and evaluated the effect of lot changes on the MU. Methods MU values were estimated using subgrouping by reagent lot changes or using the data as a whole, and both methods were compared. Reagent lot change was simulated using randomly generated data, and the mean values and MU for two IQC datasets (different QC material lots) were compared using statistical methods. Results All MU values calculated using subgrouping were lower than the total values; however, the average differences were minimal. The simulation showed that the greater the increase in the extent of the average shift, the larger the difference in MU. In IQC data comparison, the mean values and MU exhibited statistically significant differences for most analytes. The MU calculation methods gave rise to minimal differences, suggesting that IQC data in clinical laboratories show no significant shift. However, the simulation results demonstrated that notable differences in the MU can arise from significant variations in IQC results before and after a reagent lot change. Additionally, IQC material lots should be treated separately when IQC data are collected for MU estimation. Conclusions Lot changes in IQC data are a key factor affecting MU estimation and should not be overlooked during MU estimation.
Collapse
Affiliation(s)
- Hyunjung Gu
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Juhee Lee
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jinyoung Hong
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Woochang Lee
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Yeo-Min Yun
- Department of Laboratory Medicine, Konkuk University School of Medicine, Seoul, Korea
| | - Sail Chun
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Woo-In Lee
- Department of Laboratory Medicine, School of Medicine, Kyung Hee University and Kyung Hee University Hospital at Gangdong, Seoul, Korea
| | - Won-Ki Min
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
42
|
Bianchi G, Colombo G, Pasqualetti S, Panteghini M. Alignment of the new generation of Abbott Alinity γ-glutamyltransferase assay to the IFCC reference measurement system should be improved. Clin Chem Lab Med 2022; 60:e228-e231. [PMID: 35938935 DOI: 10.1515/cclm-2022-0684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 07/24/2022] [Indexed: 11/15/2022]
Affiliation(s)
- Giorgia Bianchi
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Giulia Colombo
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Sara Pasqualetti
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mauro Panteghini
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
43
|
Panteghini M. The simple reproducibility of a measurement result does not equal its overall measurement uncertainty. Clin Chem Lab Med 2022; 60:e221-e222. [PMID: 35802464 DOI: 10.1515/cclm-2022-0618] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 07/01/2022] [Indexed: 11/15/2022]
Affiliation(s)
- Mauro Panteghini
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
44
|
Plebani M. Quality in laboratory medicine and the Journal: walking together. Clin Chem Lab Med 2022; 61:713-720. [PMID: 35969689 DOI: 10.1515/cclm-2022-0755] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/15/2022]
Abstract
Quality in laboratory medicine is defined as "an unfinished journey", as the more essential the laboratory information provided, the more assured its quality should be. In the past decades, the Journal Clinical Chemistry and Laboratory Medicine has provided a valuable forum for garnering new insights into the analytical and extra-analytical phases of the testing cycle, and for debating crucial aspects of quality in clinical laboratories. The impressive number of papers published in the Journal is testimony to the efforts made by laboratory professionals, national and international scientific societies and federations in the quest to continuously improve upon the pre-, intra- and post-analytical steps of the testing cycle, thus enhancing the quality of laboratory information. The paper appearing in this special issue summarizes the most important and interesting contributions published in the Journal, thus updating our knowledge on quality in laboratory medicine and offering further stimuli to identify the most valuable measures of quality in clinical laboratories.
Collapse
Affiliation(s)
- Mario Plebani
- Clinical Biochemistry and Clinical Molecular Biology, University of Padova, Padova, Italy
- Department of Pathology, University of Texas Medical Branch, Galveston, USA
| |
Collapse
|
45
|
Nyssen L, Fillet M, Cavalier E, Servais AC. Qualitative and quantitative comparison of different commercially available 1-84 parathyroid hormone proteins to the WHO international standard 95/646 using orthogonal methods. J Pharm Biomed Anal 2022; 219:114942. [PMID: 35863167 DOI: 10.1016/j.jpba.2022.114942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 07/01/2022] [Accepted: 07/12/2022] [Indexed: 11/18/2022]
Abstract
Relative quantitation methods rely on the use of reference substances to determine the content of samples. The aim of this study was to compare 1-84 parathyroid hormone (PTH) standards from different manufacturers to the WHO international standard 95/646. CE and LC with UV detection were investigated as quick and inexpensive quantitation methods, with an emphasis on selectivity between intact 1-84 PTH and its oxidized forms. Both methods were fully validated according to ICH Q2R1. Moreover, method performance was also evaluated according to guidelines defining the maximum allowable measurement uncertainty (MU) of a biological parameter from its intraindividual variation (CVI), as well as the proportion of that MU devoted to the reference material. This study highlighted the fact that some 1-84 PTH standards have a content that is actually twice as high as the one stated on the label, which was confirmed by an amino acid analysis investigation. Our approach offers a quick and inexpensive way to estimate the content of 1-84 PTH standards.
Collapse
Affiliation(s)
- Laurent Nyssen
- Department of Clinical Chemistry, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, CHU de Liège, Liège, Belgium; Laboratory for the Analysis of Medicines (LAM), Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, Liège, Belgium
| | - Marianne Fillet
- Laboratory for the Analysis of Medicines (LAM), Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, Liège, Belgium
| | - Etienne Cavalier
- Department of Clinical Chemistry, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, CHU de Liège, Liège, Belgium
| | - Anne-Catherine Servais
- Laboratory for the Analysis of Medicines (LAM), Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, Liège, Belgium.
| |
Collapse
|
46
|
Panteghini M. Reply to Westgard et al.: 'Keep your eyes wide … as the present now will later be past'. Clin Chem Lab Med 2022; 60:e202-e203. [PMID: 35786491 DOI: 10.1515/cclm-2022-0557] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 06/08/2022] [Indexed: 01/02/2023]
Affiliation(s)
- Mauro Panteghini
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milan, Italy
| |
Collapse
|
47
|
van Schrojenstein Lantman M, Çubukçu HC, Boursier G, Panteghini M, Bernabeu-Andreu FA, Milinkovic N, Mesko Brguljan P, Linko S, Brugnoni D, O'Kelly R, Kroupis C, Lohmander M, Šprongl L, Vanstapel F, Thelen M. An approach for determining allowable between reagent lot variation. Clin Chem Lab Med 2022; 60:681-688. [PMID: 35172415 DOI: 10.1515/cclm-2022-0083] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 02/02/2022] [Indexed: 11/15/2022]
Abstract
Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Laboratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use. The APC can in part be determined by estimating the measurement uncertainty component under conditions of within-laboratory precision (uRw), which comprises all components influencing the measurement uncertainty of random sources. To maintain the adequacy of their measurement procedures, laboratories need to distinguish aspects that are manageable vs. those that are not. One of the aspects that may influence uRw is the momentary significant bias caused by shifts in reagent and/or calibrator lots, which, when accepted or unnoticed, become a factor of the APC. In this paper, we postulate a model for allocating a part of allowable uRw to between-reagent lot variation, based on the need for long-term consistency of the measurement variability for that specific measurand. The allocation manages the ratio between short-term and long-term variation and indicates laboratories when to reject or correct certain variations due to reagent lots.
Collapse
Affiliation(s)
- Marith van Schrojenstein Lantman
- Result Laboratory for Clinical Chemistry, Amphia Hospital, Breda, The Netherlands
- Department of Laboratory Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Hikmet Can Çubukçu
- Interdisciplinary Stem Cells and Regenerative Medicine, Ankara University Stem Cell Institute, Ankara, Turkey
| | - Guilaine Boursier
- Dept of Genetics, Rare Diseases and Personalized Medicine Rare Diseases and Autoinflammatory Unit, CHU Montpellier, Univ Montpellier, Montpellier, France
| | - Mauro Panteghini
- Department of Biomedical and Clinical Sciences "Luigi Sacco", and Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milano, Italy
| | | | - Neda Milinkovic
- Department of Medical Biochemistry, Faculty of Pharmacy, University of Belgrade, Belgrade, Serbia
| | - Pika Mesko Brguljan
- Department of Clinical Chemistry, University Clinic for Respiratory and Allergic Diseases, Golnik, Slovenia
| | | | - Duilio Brugnoni
- Clinical Chemistry Laboratory, Spedali Civili, Brescia, Italy
| | - Ruth O'Kelly
- Association of Clinical Biochemists in Ireland, Dublin, Ireland
| | - Christos Kroupis
- Department of Clinical Biochemistry, Medical School, Attikon University General Hospital, National and Kapodistrian University of Athens, Haidari, Greece
| | - Maria Lohmander
- Regional Laboratoriemedicin, Sahlgrenska Universitetssjukhuset, Trollhättan, Sweden
| | - Luděk Šprongl
- Clinical Laboratory, Hospital Kladno, Kladno, Czech Republic
| | - Florent Vanstapel
- Belgium and Department of Public Health, Laboratory Medicine, University Hospital Leuven, Biomedical Sciences Group, Leuven, Belgium
| | - Marc Thelen
- Result Laboratory for Clinical Chemistry, Amphia Hospital, Breda, The Netherlands
- Department of Laboratory Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| |
Collapse
|
48
|
Capoferri A, Aloisio E, Pasqualetti S, Panteghini M. More about the random uncertainty of photometric determination of hemolysis index on the Abbott Alinity c platform. Clin Biochem 2022; 105-106:94-95. [PMID: 35460611 DOI: 10.1016/j.clinbiochem.2022.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/14/2022] [Accepted: 04/19/2022] [Indexed: 11/03/2022]
Affiliation(s)
- Alessia Capoferri
- Clinical Pathology Unit, 'Luigi Sacco' University Hospital, Milan, Italy.
| | - Elena Aloisio
- Clinical Pathology Unit, 'Luigi Sacco' University Hospital, Milan, Italy
| | - Sara Pasqualetti
- Clinical Pathology Unit, 'Luigi Sacco' University Hospital, Milan, Italy
| | - Mauro Panteghini
- Clinical Pathology Unit, 'Luigi Sacco' University Hospital, Milan, Italy
| |
Collapse
|
49
|
Gifford JL, Seiden-Long I. Filling in the GAPS: validation of anion gap (AGAP) measurement uncertainty estimates for use in clinical decision making. Clin Chem Lab Med 2022; 60:851-858. [PMID: 35442590 DOI: 10.1515/cclm-2021-1279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 03/14/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVES We compare measurement uncertainty (MU) calculations to real patient result variation observed by physicians using as our model anion gap (AGAP) sequentially measured on two different instrument types. An approach for discretely quantifying the pre-analytical contributions and validating AGAP MU estimates for interpretation of patient results is proposed. METHODS AGAP was calculated from sodium, chloride, and bicarbonate reported from chemistry or blood gas analyzers which employ different methodologies and specimen types. AGAP MU was calculated using a top-down approach both assuming no correlation between measurands and alternatively, including consideration of measurand correlation. MU-derived reference change values (RCV) were calculated between chemistry and blood gas analyzers results. Observational paired AGAP data (n=39,626 subjects) was obtained from retrospectively analyzed specimens from five urban tertiary care hospitals in Calgary, Alberta, Canada. RESULTS The MU derived AGAP RCV for paired specimen data by the two platforms was 5.2-6.1 mmol/L assuming no correlation and 2.6-3.1 mmol/L assuming correlation. From the paired chemistry and blood gas data, total observed variation on a reported AGAP has a 95% confidence interval of ±6.0 mmol/L. When the MU-derived RCV assuming correlation is directly compared against the observed distribution of patient results, we obtained a pre-analytical variation contribution of 2.9-3.5 mmol/L to the AGAP observed variation. In contrast, assuming no correlation leads to a negligible pre-analytical contribution (<1.0 mmol/L). CONCLUSIONS MU estimates assuming no correlation are more representative of the total variation seen in real patient data. We present a pragmatic approach for validating an MU calculation to inform clinical decisions and determine the pre-analytical contribution to MU in this system.
Collapse
Affiliation(s)
- Jessica L Gifford
- Alberta Precision Laboratories and Department of Pathology and Laboratory Medicine, University of Calgary, Calgary, Canada
| | - Isolde Seiden-Long
- Alberta Precision Laboratories and Department of Pathology and Laboratory Medicine, University of Calgary, Calgary, Canada
| |
Collapse
|
50
|
Pasqualetti S, Carnevale A, Dolci A, Panteghini M. A step towards optimal efficiency of HbA 1c measurement as a first-line laboratory test: the TOP-HOLE (Towards OPtimal glycoHemOgLobin tEsting) project. Clin Chem Lab Med 2022; 60:441-450. [PMID: 35041303 DOI: 10.1515/cclm-2021-1249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 01/06/2022] [Indexed: 12/30/2022]
Abstract
OBJECTIVES The TOP-HOLE (Towards OPtimal glycoHemOgLobin tEsting) project aimed to validate the HbA1c enzymatic method on the Abbott Alinity c platform and to implement the HbA1c testing process on the total laboratory automation (TLA) system of our institution. METHODS Three different measuring systems were employed: Architect c4000 stand-alone (s-a), Alinity c s-a, and Alinity c TLA. Eight frozen whole blood samples, IFCC value-assigned, were used for checking trueness. A comparison study testing transferability of HbA1c results from Architect to Alinity was also performed. The alignment of Alinity TLA vs. s-a was verified and the measurement uncertainty (MU) estimated according to ISO 20914:2019. Turnaround time (TAT) and full time equivalent (FTE) were used as efficiency indicators. RESULTS For HbA1c concentrations covering cut-offs adopted in clinical setting, the bias for both Architect and Alinity s-a was negligible. When compared with Architect, Alinity showed a mean positive bias of 0.54 mmol/mol, corresponding to a mean difference of 0.87%. A perfect alignment of Alinity TLA to the Alinity s-a was shown, and a MU of 1.58% was obtained, widely fulfilling the desirable 3.0% goal. After the full automation of HbA1c testing, 90% of results were released with a maximum TAT of 1 h, 0.30 FTE resource was also saved. CONCLUSIONS The traceability of Alinity HbA1c enzymatic assay to the IFCC reference system was correctly implemented. We successfully completed the integration of the HbA1c testing on our TLA system, without worsening the optimal analytical performance. The shift of HbA1c testing from s-a mode to TLA significantly decreased TAT.
Collapse
Affiliation(s)
- Sara Pasqualetti
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | | | - Alberto Dolci
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
- Department of Biomedical and Clinical Sciences 'Luigi Sacco', University of Milan, Milan, Italy
| | - Mauro Panteghini
- Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Milan, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
- Department of Biomedical and Clinical Sciences 'Luigi Sacco', University of Milan, Milan, Italy
| |
Collapse
|