1
|
Liu Y, Xia L, Dutta D. Reduction in sample injection bias using pressure gradients generated on chip. Electrophoresis 2021; 42:983-990. [PMID: 33569844 DOI: 10.1002/elps.202000299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/21/2021] [Accepted: 01/29/2021] [Indexed: 11/10/2022]
Abstract
Sample injection in microchip-based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on-chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure-generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure-driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4-6 for the analyte peaks in a 3 cm long analysis channel.
Collapse
Affiliation(s)
- Yukari Liu
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| | - Ling Xia
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| | - Debashis Dutta
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| |
Collapse
|
2
|
Akram M, Asghar MN, Saleem Khan M, Shahid S, Abdur Rahman HM, Nadeem I. Development and validation of an economical uric acid-Fe3+/Fe2+-ferrozine-based colorimetric assay to estimate uric acid level of pure and biological samples. Biosci Biotechnol Biochem 2020; 84:1967-1974. [DOI: 10.1080/09168451.2020.1781593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Abstract
This work presents the development and validation of a simple, rapid, and cost-effective spectrophotometric method for quantitative analysis of uric acid in biological samples. The method relies upon uric acid-led reduction of Fe(III) to Fe(II) of sample/standard solutions which stoichiometrically engages ferrozine to form a magenta-colored complex. Different parameters including pH, metal and chelator concentrations, temperature, etc., were optimized for the maximum intensity and stability of the complex. The uric acid concentrations of synthetic/plasma solutions were determined by comparing the color intensity of Fe(ferrozine)32+ complex produced by test solution with the standard curve formed by known uric acid concentrations. The method was validated in accordance with ICH guidelines and subjected to human plasma analysis. The results obtained were compared with a reference (enzymatic) method which revealed that there was no significant difference between the two methods at 95% confidence level. The method is highly specific, precise, linear, accurate, and robust.
Collapse
Affiliation(s)
- Maryam Akram
- Department of Chemistry, Forman Christian College (A Chartered University), Lahore, Pakistan
| | - Muhammad Nadeem Asghar
- Department of Chemistry, Forman Christian College (A Chartered University), Lahore, Pakistan
| | - Maria Saleem Khan
- Department of Chemistry, Forman Christian College (A Chartered University), Lahore, Pakistan
| | - Sammia Shahid
- Department of Chemistry, School of Science and Technology, University of Management and Technology, Lahore, Pakistan
| | | | - Iram Nadeem
- Department of Chemistry, COMSATS University Islamabad, Lahore Campus, Pakistan
| |
Collapse
|
3
|
Gwladys Ekwe Priso J, Pierre Nda Mefo’o J, Okalla Ebongue C, Ngouadjeu Dongho Tsakeu E, Akono Ndi C, Beyiha G, Solange Doualla M, Adiogo D. Electrophoretic Profile of Serum Proteins Using Capillary Technique in Patients Attending the Douala General Hospital, Cameroon. AVICENNA JOURNAL OF MEDICAL BIOCHEMISTRY 2018. [DOI: 10.15171/ajmb.2018.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background: Electrophoresis of serum proteins is an orientation examination routinely used in clinical practice. For a few years, agarose gel electrophoresis has tended to be replaced with capillary electrophoresis owing to an increase in the accuracy of results. However, this technique is uncommon and is not widely used in Cameroon. Objectives: The research aimed at studying the electrophoretic profile of serum proteins using capillary technique among patients attending the Douala General Hospital, Cameroon. Methods: Capillary electrophoresis was used to carry out tests on blood samples from any inpatients and outpatients and fasting for 8-12 hours. Capillary electrophoresis of serum samples was used for the separation of proteins into six fractions and the total protidemia of each serum samples was determined using the Biuret method. Results were interpreted by observing the shape of curves and quantitative variations in each fraction of the different serum proteins. Results: A total of 311 patients participated in the study. The sampled population aged 50±18 years on average and consisted of 55.3% men and 44.7% women. All capillary electrophoresis profiles presented six protein fractions, namely, albumin, alpha (1 and 2), beta (1 and 2) and gamma globulins. Pathological disorders were diagnosed in 290 patients and 21 patients had normal results. Inflammatory syndromes accounted for 63.34% and monoclonal gammopathies for 10.29% the main pathological disorder identified. Conclusion: Capillary electrophoresis provides a more precise identification of biological syndromes and clear distinction of the six fractions of each protein. Monoclonal profiles and inflammatory syndromes were well detected. A prevalence of 10.29% was determined for gammopathies.
Collapse
Affiliation(s)
| | - Jean Pierre Nda Mefo’o
- Clinical Biology Laboratory, Douala General Hospital, Cameroon
- Department of Biological Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| | - Cécile Okalla Ebongue
- Clinical Biology Laboratory, Douala General Hospital, Cameroon
- Department of Biological Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| | - Eveline Ngouadjeu Dongho Tsakeu
- Clinical Biology Laboratory, Douala General Hospital, Cameroon
- Department of Biological Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| | - Catherine Akono Ndi
- Clinical Biology Laboratory, Douala General Hospital, Cameroon
- Department of Biological Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| | - Gérard Beyiha
- Department of Clinical Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| | - Marie Solange Doualla
- Department of Clinical Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| | - Dieudonné Adiogo
- Department of Biological Sciences, Faculty of Medicine and Pharmaceutical Sciences, Douala, Cameroon
| |
Collapse
|
4
|
Neaga I, Bodoki E, Hambye S, Blankert B, Oprean R. Study of nucleic acid–ligand interactions by capillary electrophoretic techniques: A review. Talanta 2016; 148:247-56. [DOI: 10.1016/j.talanta.2015.10.077] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Revised: 10/21/2015] [Accepted: 10/25/2015] [Indexed: 10/22/2022]
|
5
|
Li SK, Liddell MR, Wen H. Effective electrophoretic mobilities and charges of anti-VEGF proteins determined by capillary zone electrophoresis. J Pharm Biomed Anal 2011; 55:603-7. [PMID: 21269789 DOI: 10.1016/j.jpba.2010.12.027] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2010] [Revised: 12/12/2010] [Accepted: 12/17/2010] [Indexed: 11/15/2022]
Abstract
Macromolecules such as therapeutic proteins currently serve an important role in the treatment of eye diseases such as wet age-related macular degeneration and diabetic retinopathy. Particularly, bevacizumab and ranibizumab have been shown to be effective in the treatment of these diseases. Iontophoresis can be employed to enhance ocular delivery of these macromolecules, but the lack of information on the properties of these macromolecules has hindered its development. The objectives of the present study were to determine the effective electrophoretic mobilities and charges of bevacizumab, ranibizumab, and model compound polystyrene sulfonate (PSS) using capillary zone electrophoresis. Salicylate, lidocaine, and bovine serum albumin (BSA), which have known electrophoretic mobilities in the literature, were also studied to validate the present technique. The hydrodynamic radii and diffusion coefficients of BSA, bevacizumab, ranibizumab, and PSS were measured by dynamic light scattering. The effective charges were calculated using the Einstein relation between diffusion coefficient and electrophoretic mobility and the Henry equation. The results show that bevacizumab and ranibizumab have low electrophoretic mobilities and are net negatively charged in phosphate buffered saline (PBS) of pH 7.4 and 0.16M ionic strength. PSS has high negative charge but the electrophoretic mobility in PBS is lower than that expected from the polymer structure. The present study demonstrated that capillary electrophoresis could be used to characterize the mobility and charge properties of drug candidates in the development of iontophoretic drug delivery.
Collapse
Affiliation(s)
- S Kevin Li
- Division of Pharmaceutical Sciences, College of Pharmacy, University of Cincinnati, 3225 Eden Ave, 136 HPB, Cincinnati, OH 45267, United States.
| | | | | |
Collapse
|
6
|
Bazylak G, Monge ME, Everaert J, Nagels LJ. Hydrophobicity-aided potentiometric detection of catecholamines, beta-agonists, and beta-blockers in a mixed-solvent capillary electrophoresis system. J Sep Sci 2009; 32:135-46. [DOI: 10.1002/jssc.200800450] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
7
|
Zhao S, Wang J, Ye F, Liu YM. Determination of uric acid in human urine and serum by capillary electrophoresis with chemiluminescence detection. Anal Biochem 2008; 378:127-31. [DOI: 10.1016/j.ab.2008.04.014] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2007] [Revised: 04/04/2008] [Accepted: 04/07/2008] [Indexed: 11/28/2022]
|
8
|
Pasteurella multocida sialic acid aldolase: a promising biocatalyst. Appl Microbiol Biotechnol 2008; 79:963-70. [PMID: 18521592 DOI: 10.1007/s00253-008-1506-2] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2008] [Revised: 04/06/2008] [Accepted: 04/14/2008] [Indexed: 10/22/2022]
Abstract
Sialic acid aldolases or N-acetylneuraminate lyases (NanAs) catalyze the reversible aldol cleavage of N-acetylneuraminic acid (Neu5Ac) to form pyruvate and N-acetyl-D: -mannosamine (ManNAc). A capillary electrophoresis assay was developed to directly characterize the activities of NanAs in both Neu5Ac cleavage and Neu5Ac synthesis directions. The assay was used to obtain the pH profile and the kinetic data of a NanA cloned from Pasteurella multocida P-1059 (PmNanA) and a previously reported recombinant Escherichia coli K12 NanA (EcNanA). Both enzymes are active in a broad pH range of 6.0-9.0 in both reaction directions and have similar kinetic parameters. Substrates specificity studies showed that 5-O-methyl-ManNAc, a ManNAc derivative, can be used efficiently as a substrate by PmNanA, but not efficiently by EcNanA, for the synthesis of 8-O-methyl Neu5Ac. In addition, PmNanA (250 mg l(-1) culture) has a higher expression level (2.5-fold) than EcNanA (94 mg l(-1) culture). The higher expression level and a broader substrate tolerance make PmNanA a better catalyst than EcNanA for the chemoenzymatic synthesis of sialic acids and their derivatives.
Collapse
|
9
|
Abstract
There has been increased activity in the last few years in the search for disease markers using fractionation of complex biological fluids combined with MS. While electrophoretic and chromatographic separations have played a major role in this endeavor, this manuscript is limited to a review of electrophoretic methods that have been established for disease biomarker discovery. These methods include 2-DE, difference gel electrophoresis (DIGE), and CE. We define what constitutes a biomarker, identify the steps required for establishing a biomarker, and describe the parameters needed in the design of an ideal diagnostic test. The application, advantages, and limitations of CE, DIGE, and 2-DE in meeting the goal of discovering novel biomarkers is discussed in detail, along with a few selected examples that illustrate the search for biomarkers for cancer and neurological diseases.
Collapse
Affiliation(s)
- Haleem J Issaq
- Laboratory of Proteomics and Analytical Technologies, SAIC-Frederick, Inc., NCI-Frederick, Frederick, MD 21702, USA.
| | | |
Collapse
|
10
|
Abstract
Proteomic technologies are used with increasing frequency in the renal community. In this review, we highlight the use in renal research of a number of available techniques including two-dimensional gel electrophoresis, liquid chromatography/mass spectrometry, surface-enhanced laser desorption/ionization, capillary electrophoresis/mass spectrometry, and antibody and tissue arrays. These techniques have been used to identify proteins or changes in proteins specific to regions of the kidney or associated with renal diseases or toxicity. They have also been used to examine protein expression changes and posttranslational modifications of proteins during signaling. A number of studies have used proteomic methodologies to look for diagnostic biomarkers in body fluids. The rapid rate of development of the technologies along with the combination of classic physiological and biochemical techniques with proteomics will enable new discoveries.
Collapse
Affiliation(s)
- Michael G Janech
- Medical University of South Carolina, Ralph H. Johnson Veterans Affairs Medical Center, Charleston, SC 29425-2220, USA
| | | | | |
Collapse
|
11
|
Saleh S, Hempel G. Quantification of ganciclovir in human plasma using capillary electrophoresis. Electrophoresis 2006; 27:2439-43. [PMID: 16718717 DOI: 10.1002/elps.200500903] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A fast, simple, specific capillary electrophoretic method in the MEKC mode for the quantification of the antiviral drug ganciclovir is described. The separation was obtained using a 50 microm id fused-silica capillary, 60 mM borax buffer (pH 9.25) containing 40 mM SDS using ethenoadenosine as the internal standard. Sample preparation was done by ultrafiltration with a Microcon 30 000 kDa filter. The analytes were detected with UV detector at 254 nm. A sufficient sensitivity was achieved by using a bubble cell capillary. The linear range was from 0.5 to 10 mg/L with a LOQ of 0.5 mg/L. Correlation coefficients were better than 0.999 whereas inter- and intraday precision and accuracy were less than 10.7%. The analysis of patients' samples after administration of ganciclovir indicates that the method is suitable for drug monitoring in the clinic.
Collapse
Affiliation(s)
- Soundos Saleh
- Klinik und Poliklinik für Kinder- und Jugendmedizin--Pädiatrische Hämatologie und Onkologie, Münster, Germany
| | | |
Collapse
|
12
|
Sekula J, Everaert J, Bohets H, Vissers B, Pietraszkiewicz M, Pietraszkiewicz O, Du Prez F, Vanhoutte K, Prus P, Nagels LJ. Coated Wire Potentiometric Detection for Capillary Electrophoresis Studied Using Organic Amines, Drugs, and Biogenic Amines. Anal Chem 2006; 78:3772-9. [PMID: 16737236 DOI: 10.1021/ac060066y] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Capillary electrophoresis was coupled successfully and reliably to potentiometric sensors, which are based on an ionically conductive rubber phase coating, applied on a 250 microm diameter metal substrate. The membrane components included potassium tetrakis(p-chlorophenyl)borate (TCPB), bis(2-ethylhexyl)sebacate (DOS), and high molecular mass poly(vinyl chloride) (PVC). Potentiometry reveals a very sensitive CE detection mode, with sub-micromolar detection limits for amines and the randomly chosen drugs quinine, clozapine, cocaine, heroine, noscapine, papaverine, and ritodrine. The lowest detection limit, 1 x 10(-8) M injected concentration, was obtained for the quaternary ammonium compound tetrahexylammonium chloride. The more polar lower aliphatic amines and the biogenic amines dopamine, adrenaline, and cadaverine have much higher detection limits. The detection limits are log P dependent. Addition of a commercially available calixarene molecule or a synthetic macrocyclic amphiphilic receptor molecule to the electrode coatings enhanced the sensitivity respectively for the lower aliphatic amines and for the biogenic amines. A transpose of the Nikolskii-Eisenman-type function was suggested and used to convert the signal of the detector to a concentration-dependent signal.
Collapse
Affiliation(s)
- Justyna Sekula
- Chemistry Department, Antwerp University, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
He X, Hauan S. Microfluidic modeling and design for continuous flow in electrokinetic mixing-reaction channels. AIChE J 2006. [DOI: 10.1002/aic.10985] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
14
|
Zinellu A, Sotgia S, Caddeo S, Deiana L, Carru C. Sodium glycylglycine as effective electrolyte run buffer for ascorbic and uric acid separation by CZE: A comparison with two other CE assays. J Sep Sci 2005; 28:2193-9. [PMID: 16318217 DOI: 10.1002/jssc.200500109] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A new CE method for ascorbic acid (AA) and uric acid (UA) detection in human plasma has been developed. Analytes were resolved in less than 4 min by employing sodium glycylglycine (Glygly) as electrolyte run buffer at pH 8.0. Using the diode array detector ability to measure multiple wavelengths simultaneously, detection was optimized by monitoring the run at 262 nm for AA and at 288 nm for UA. Electrophoretic parameters such as resolution, migration times, efficiency, and peak areas of this new method were compared to those obtained by the two CE assays described in literature, in which the analytes separation was achieved by using sodium borate (that allows faster migration times but poor resolution) or tricine (with the highest resolution but elevated migration times) as electrolyte run buffer. Sodium Glygly allows to obtain the same good resolution given by the tricine buffer but with the faster analysis times of the sodium borate run buffer. Ascorbate and urate levels were measured in 35 healthy volunteers by the three methods and the obtained data were compared by three different statistical tests (mountain plot, Passing-Bablok regression, and Bland-Altman test) in order to verify the accuracy of our proposed method.
Collapse
Affiliation(s)
- Angelo Zinellu
- Clinical Biochemistry, University of Sassari, Sassari, Italy
| | | | | | | | | |
Collapse
|
15
|
Miao H, Rubakhin SS, Sweedler JV. Confirmation of peak assignments in capillary electrophoresis using immunoprecipitation. Application to D-aspartate measurements in neurons. J Chromatogr A 2005; 1106:56-60. [PMID: 16199049 DOI: 10.1016/j.chroma.2005.09.037] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2005] [Revised: 09/14/2005] [Accepted: 09/16/2005] [Indexed: 10/25/2022]
Abstract
Capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection is a powerful tool for analysis of samples ranging from tissue extracts to single cells. However, accurate peak identification in electropherograms is challenging when complex biological samples are analyzed, as often matching a migration time between an analyte and corresponding standard may be insufficient to confirm the peak's identity. A method which combines single-step immunoprecipitation and CE-LIF analysis for investigation of the chiral amino acids in single cells and small tissue samples is demonstrated. D-Aspartate (D-Asp) has been reported in the central nervous system of the invertebrate neurobiological model Aplysia californica. In order to confirm the identity of D-Asp signal in the complex electropherograms of nerve tissue extracts and individual neurons, anti-D-Asp serum, preincubated with L-Asp conjugate, is added to the sample. This selectively binds the free D-Asp, creating an antibody-antigen complex with a migration time similar to that of antibody alone, but not that of D-Asp. The complete disappearance of the putative D-Asp peak confirms its identity and validates that there are no other detectable analytes co-migrating with D-Asp in the electropherogram.
Collapse
Affiliation(s)
- Hai Miao
- Department of Chemistry, University of Illinois, Champaign, School of Chemical Sciences, 600 South Mathews Avenue 63-5, Urbana, IL 61801, USA
| | | | | |
Collapse
|
16
|
Iadarola P, Cetta G, Luisetti M, Annovazzi L, Casado B, Baraniuk J, Zanone C, Viglio S. Micellar electrokinetic chromatographic and capillary zone electrophoretic methods for screening urinary biomarkers of human disorders: a critical review of the state-of-the-art. Electrophoresis 2005; 26:752-766. [PMID: 15669008 DOI: 10.1002/elps.200410195] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Human urine plays a central role in clinical diagnostic being one of the most-frequently used body fluid for detection of biological markers. Samples from patients with different diseases display patterns of biomarkers that differ significantly from those obtained from healthy subjects. The availability of fast, reproducible, and easy-to-apply analytical techniques that would allow identification of a large number of these analytes is thus highly desiderable since they may provide detailed information about the progression of a pathological process. From among the variety of methods so far applied for the determination of urinary metabolites, capillary electrophoresis, both in the capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) modes, represents a robust and reliable analytical tool widely used in this area. The aim of the present article is to focus the interest of the reader on recent applications of MEKC and CZE in the field of urinary biomarkers and to discuss advantages and/or limitations of each mode.
Collapse
Affiliation(s)
- Paolo Iadarola
- Dipartimento di Biochimica A.Castellani, Università di Pavia, Pavia, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Zamfir A, Peter-Katalinić J. Capillary electrophoresis-mass spectrometry for glycoscreening in biomedical research. Electrophoresis 2004; 25:1949-1963. [PMID: 15237394 DOI: 10.1002/elps.200405825] [Citation(s) in RCA: 108] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Application of capillary electrophoresis (CE) in combination with mass spectrometry (MS) and tandem MS to glycoscreening in biomedical projects is highlighted. In the first part recent CE-MS experiments by sheath liquid CE and multiple stage MS are reported. Neutral and negatively charged N-glycan mixtures from ribonuclease B and fetuin, high-mannose type N-glycoforms, oligosaccharides from lipopolysaccharides (LPS) of Haemophilus influenzae, polysaccharides of Pseudomonas aeruginosa and Staphylococcus aureus were analyzed. A particular emphasis is devoted to the applicability of novel off- and on-line CE-MS and tandem MS methods for screening of proteoglycan-derived oligosaccharides, glycosaminoglycans (GAGs), such as hyaluronates from Streptococcus agalactiae, chondroitin/dermatan sulfates (CS/DS) from bovine aorta and human skin fibroblast decorin, and heparin/heparan sulfate (HS) from porcine and bovine mucosa. The performance of CE-MS/MS for identification of glycoforms in glycopeptides and glycoproteins is illustrated by experiments performed on complex mixtures from urine of patients suffering from a hereditary N-acetylhexosaminidase deficiency (Schindler's disease) and urine of patients suffering from cancer cachexia. For determination of glycosylation patterns in glycoproteins like enzymes and antibodies by CE/MS, both CE-matrix assisted laser desorption/ionization (MALDI) and CE-electrospray ionization (ESI)-MS were functional. Finally, the potential of CE-ESI-MS strategy in glycolipid analysis is demonstrated for gangliosides from bovine brain for which particular CE buffer conditions are required.
Collapse
Affiliation(s)
- Alina Zamfir
- Institute for Medical Physics and Biophysics, Biomedical Analysis Department, University of Münster, Münster, Germany
| | - Jasna Peter-Katalinić
- Institute for Medical Physics and Biophysics, Biomedical Analysis Department, University of Münster, Münster, Germany
| |
Collapse
|
18
|
Zinellu A, Carru C, Sotgia S, Deiana L. Optimization of ascorbic and uric acid separation in human plasma by free zone capillary electrophoresis ultraviolet detection. Anal Biochem 2004; 330:298-305. [PMID: 15203336 DOI: 10.1016/j.ab.2004.04.009] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2004] [Indexed: 02/04/2023]
Abstract
In this paper we propose a new fast free zone capillary electrophoresis method for the simultaneous determination of ascorbic acid (AA) and uric acid (UA) in human plasma. We investigated the effect of analytical parameters, such as concentration and pH of borate running buffer, cartridge temperature, and sample treatment, on resolution, migration times, corrected peak areas, and efficiency. A good separation was achieved using a 60.2-cmx75-microm uncoated silica capillary and 100 mmol/L sodium borate buffer, pH 8, when metaphosphoric acid was employed as protein precipitant, in less than 4 min. These conditions gave a good reproducibility of migration times (CV 0.35 and 0.34%) and peak areas (CV 3.2 and 3.1%) for ascorbate and urate, respectively. The limit of detection was 0.5mg/L for both analytes when the detection was performed at 254 nm for AA and at 292 nm for UA. We compared the present method with a validated capillary electrophoresis assay by measuring plasma urate and ascorbate in 32 normal subjects and the obtained data were analyzed by the Passing and Bablok regression.
Collapse
Affiliation(s)
- Angelo Zinellu
- Chair of Clinical Biochemistry, University of Sassari, 07100 Sassari, Italy
| | | | | | | |
Collapse
|