Cao Q, Deng R, Pan Y, Liu R, Chen Y, Gong G, Zou J, Yang H, Han D. Robotic wireless capsule endoscopy: recent advances and upcoming technologies. Nat Commun 2024; 15:4597. [PMID: 38816464 PMCID: PMC11139981 DOI: 10.1038/s41467-024-49019-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 05/21/2024] [Indexed: 06/01/2024] Open
Abstract
Wireless capsule endoscopy (WCE) offers a non-invasive evaluation of the digestive system, eliminating the need for sedation and the risks associated with conventional endoscopic procedures. Its significance lies in diagnosing gastrointestinal tissue irregularities, especially in the small intestine. However, existing commercial WCE devices face limitations, such as the absence of autonomous lesion detection and treatment capabilities. Recent advancements in micro-electromechanical fabrication and computational methods have led to extensive research in sophisticated technology integration into commercial capsule endoscopes, intending to supersede wired endoscopes. This Review discusses the future requirements for intelligent capsule robots, providing a comparative evaluation of various methods' merits and disadvantages, and highlighting recent developments in six technologies relevant to WCE. These include near-field wireless power transmission, magnetic field active drive, ultra-wideband/intrabody communication, hybrid localization, AI-based autonomous lesion detection, and magnetic-controlled diagnosis and treatment. Moreover, we explore the feasibility for future "capsule surgeons".
Collapse
Affiliation(s)
- Qing Cao
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Runyi Deng
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yue Pan
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Ruijie Liu
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yicheng Chen
- Sir Run-Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Guofang Gong
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Jun Zou
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Huayong Yang
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Dong Han
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China.
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China.
| |
Collapse
|
2
|
Blümler P, Raudzus F, Schmid F. A comprehensive approach to characterize navigation instruments for magnetic guidance in biological systems. Sci Rep 2024; 14:7879. [PMID: 38570608 PMCID: PMC10991419 DOI: 10.1038/s41598-024-58091-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 03/25/2024] [Indexed: 04/05/2024] Open
Abstract
Achieving non-invasive spatiotemporal control over cellular functions, tissue organization, and behavior is a desirable aim for advanced therapies. Magnetic fields, due to their negligible interaction with biological matter, are promising for in vitro and in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic (including superparamagnetic and ferromagnetic, all with a positive magnetic susceptibility) entities through magnetic instruments has emerged as a promising approach across various biological contexts. However, variations in the properties and descriptions of these instruments have led to a lack of reproducibility and comparability among studies. This article addresses the need for standardizing the characterization of magnetic instruments, with a specific focus on their ability to control the movement of paramagnetic objects within organisms. While it is well known that the force exerted on magnetic particles depends on the spatial variation (gradient) of the magnetic field, the magnitude of the field is often overlooked in the literature. Therefore, we comprehensively analyze and discuss both actors and propose a novel descriptor, termed 'effective gradient', which combines both dependencies. To illustrate the importance of both factors, we characterize different magnet systems and relate them to experiments involving superparamagnetic nanoparticles. This standardization effort aims to enhance the reproducibility and comparability of studies utilizing magnetic instruments for biological applications.
Collapse
Affiliation(s)
- Peter Blümler
- Institute of Physics, University of Mainz, 55128, Mainz, Germany.
| | - Fabian Raudzus
- Department of Clinical Application, Center for iPS Cell Research and Application (CiRA), Kyoto University, Kyoto, Japan.
- Neuronal Signaling and Regeneration Unit, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
- Medical Education Center/International Education Section, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
| | | |
Collapse
|
3
|
Wu H, Li C, Masood M, Zhang Z, González-Almela E, Castells-Garcia A, Zou G, Xu X, Wang L, Zhao G, Yu S, Zhu P, Wang B, Qin D, Liu J. Static Magnetic Fields Regulate T-Type Calcium Ion Channels and Mediate Mesenchymal Stem Cells Proliferation. Cells 2022; 11:cells11152460. [PMID: 35954307 PMCID: PMC9368660 DOI: 10.3390/cells11152460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 07/31/2022] [Accepted: 08/01/2022] [Indexed: 11/16/2022] Open
Abstract
The static magnetic fields (SMFs) impact on biological systems, induce a variety of biological responses, and have been applied to the clinical treatment of diseases. However, the underlying mechanisms remain largely unclear. In this report, by using human mesenchymal stem cells (MSCs) as a model, we investigated the biological effect of SMFs at a molecular and cellular level. We showed that SMF exposure promotes MSC proliferation and activates the expression of transcriptional factors such as FOS (Fos Proto-Oncogene, AP-1 Transcription Factor Subunit) and EGR1 (Early Growth Response 1). In addition, the expression of signal-transduction proteins p-ERK1/2 and p-JNK oscillate periodically with SMF exposure time. Furthermore, we found that the inhibition of the T-type calcium ion channels negates the biological effects of SMFs on MSCs. Together, we revealed that the SMFs regulate T-type calcium ion channels and mediate MSC proliferation via the MAPK signaling pathways.
Collapse
Affiliation(s)
- Haokaifeng Wu
- CAS Key Laboratory of Regenerative Biology, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
- Guangdong Provincial Key Laboratory of Stem Cell and Regenerative Medicine, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
| | - Chuang Li
- School of Life Sciences, University of Science and Technology of China, Hefei 230026, China
| | - Muqaddas Masood
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510100, China
| | - Zhen Zhang
- CAS Key Laboratory of Regenerative Biology, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
- Guangdong Provincial Key Laboratory of Stem Cell and Regenerative Medicine, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
| | | | | | | | - Xiaoduo Xu
- School of Life Sciences, University of Science and Technology of China, Hefei 230026, China
| | - Luqin Wang
- CAS Key Laboratory of Regenerative Biology, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
- Guangdong Provincial Key Laboratory of Stem Cell and Regenerative Medicine, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
| | | | - Shengyong Yu
- CAS Key Laboratory of Regenerative Biology, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
- Guangdong Provincial Key Laboratory of Stem Cell and Regenerative Medicine, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
| | - Ping Zhu
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510100, China
| | - Bo Wang
- Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510100, China
| | - Dajiang Qin
- Key Laboratory of Biological Targeting Diagnosis, Therapy and Rehabilitation of Guangdong Higher Education Institutes, The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou 510000, China
- Correspondence: (D.Q.); (J.L.)
| | - Jing Liu
- CAS Key Laboratory of Regenerative Biology, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
- Guangdong Provincial Key Laboratory of Stem Cell and Regenerative Medicine, Guangzhou Institute of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China
- Bioland Laboratory, Guangzhou 510005, China
- Correspondence: (D.Q.); (J.L.)
| |
Collapse
|
4
|
Barducci L, Scaglioni B, Martin J, Obstein KL, Valdastri P. Active Stabilization of Interventional Tasks Utilizing a Magnetically Manipulated Endoscope. Front Robot AI 2022; 9:854081. [PMID: 35494547 PMCID: PMC9047764 DOI: 10.3389/frobt.2022.854081] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 03/17/2022] [Indexed: 01/16/2023] Open
Abstract
Magnetically actuated robots have become increasingly popular in medical endoscopy over the past decade. Despite the significant improvements in autonomy and control methods, progress within the field of medical magnetic endoscopes has mainly been in the domain of enhanced navigation. Interventional tasks such as biopsy, polyp removal, and clip placement are a major procedural component of endoscopy. Little advancement has been done in this area due to the problem of adequately controlling and stabilizing magnetically actuated endoscopes for interventional tasks. In the present paper we discuss a novel model-based Linear Parameter Varying (LPV) control approach to provide stability during interventional maneuvers. This method linearizes the non-linear dynamic interaction between the external actuation system and the endoscope in a set of equilibria, associated to different distances between the magnetic source and the endoscope, and computes different controllers for each equilibrium. This approach provides the global stability of the overall system and robustness against external disturbances. The performance of the LPV approach is compared to an intelligent teleoperation control method (based on a Proportional Integral Derivative (PID) controller), on the Magnetic Flexible Endoscope (MFE) platform. Four biopsies in different regions of the colon and at two different system equilibria are performed. Both controllers are asked to stabilize the endoscope in the presence of external disturbances (i.e. the introduction of the biopsy forceps through the working channel of the endoscope). The experiments, performed in a benchtop colon simulator, show a maximum reduction of the mean orientation error of the endoscope of 45.8% with the LPV control compared to the PID controller.
Collapse
Affiliation(s)
- Lavinia Barducci
- STORM Lab United Kingdom, Institute of Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom
| | - Bruno Scaglioni
- STORM Lab United Kingdom, Institute of Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom
| | - James Martin
- STORM Lab United Kingdom, Institute of Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom
| | - Keith L. Obstein
- STORM Lab United States, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Pietro Valdastri
- STORM Lab United Kingdom, Institute of Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
5
|
Chiurazzi M, Damone A, Finocchiaro M, Farnesi F, Secco GL, Forcignano E, Arezzo A, Ciuti G. Small bowel to closest human body surface distance calculation through a custom-made software using CT-based datasets. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:2903-2909. [PMID: 34891853 DOI: 10.1109/embc46164.2021.9630828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Screening of the gastrointestinal tract is imperative for the detection and treatment of physiological and pathological disorders in humans. Ingestible devices (e.g., magnetic capsule endoscopes) represent an alternative to conventional flexible endoscopy for reducing the invasiveness of the procedure and the related patient's discomforts. However, to properly design localization and navigation strategies for capsule endoscopes, the knowledge of anatomical features is paramount. Therefore, authors developed a semi-automatic software for measuring the distance between the small bowel and the closest human external body surface, using CT colonography images. In this study, volumetric datasets of 30 patients were processed by gastrointestinal endoscopists with the dedicated custom-made software and results showed an average distance of 79.29 ± 23.85 mm.
Collapse
|
6
|
Zhang J. Evolving from Laboratory Toys towards Life-Savers: Small-Scale Magnetic Robotic Systems with Medical Imaging Modalities. MICROMACHINES 2021; 12:1310. [PMID: 34832722 PMCID: PMC8620623 DOI: 10.3390/mi12111310] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 10/15/2021] [Accepted: 10/20/2021] [Indexed: 12/23/2022]
Abstract
Small-scale magnetic robots are remotely actuated and controlled by an externally applied magnetic field. These robots have a characteristic size ranging from several millimetres down to a few nanometres. They are often untethered in order to access constrained and hard-to-reach space buried deep in human body. Thus, they promise to bring revolutionary improvement to minimally invasive diagnostics and therapeutics. However, existing research is still mostly limited to scenarios in over-simplified laboratory environment with unrealistic working conditions. Further advancement of this field demands researchers to consider complex unstructured biological workspace. In order to deliver its promised potentials, next-generation small-scale magnetic robotic systems need to address the constraints and meet the demands of real-world clinical tasks. In particular, integrating medical imaging modalities into the robotic systems is a critical step in their evolution from laboratory toys towards potential life-savers. This review discusses the recent efforts made in this direction to push small-scale magnetic robots towards genuine biomedical applications. This review examines the accomplishment achieved so far and sheds light on the open challenges. It is hoped that this review can offer a perspective on how next-generation robotic systems can not only effectively integrate medical imaging methods, but also take full advantage of the imaging equipments to enable additional functionalities.
Collapse
Affiliation(s)
- Jiachen Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| |
Collapse
|
7
|
Magnetic Guiding with Permanent Magnets: Concept, Realization and Applications to Nanoparticles and Cells. Cells 2021; 10:cells10102708. [PMID: 34685688 PMCID: PMC8535073 DOI: 10.3390/cells10102708] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 09/01/2021] [Accepted: 09/02/2021] [Indexed: 02/06/2023] Open
Abstract
The idea of remote magnetic guiding is developed from the underlying physics of a concept that allows for bijective force generation over the inner volume of magnet systems. This concept can equally be implemented by electro- or permanent magnets. Here, permanent magnets are in the focus because they offer many advantages. The equations of magnetic fields and forces as well as velocities are derived in detail and physical limits are discussed. The special hydrodynamics of nanoparticle dispersions under these circumstances is reviewed and related to technical constraints. The possibility of 3D guiding and magnetic imaging techniques are discussed. Finally, the first results in guiding macroscopic objects, superparamagnetic nanoparticles, and cells with incorporated nanoparticles are presented. The constructed magnet systems allow for orientation, movement, and acceleration of magnetic objects and, in principle, can be scaled up to human size.
Collapse
|
8
|
Freitas RB, Rodrigues JA, Puga H, Correia JH. Design, simulation, and fabrication of an ingestible capsule with gastric balloon for obesity treatment. Biomed Phys Eng Express 2021; 7. [PMID: 34388748 DOI: 10.1088/2057-1976/ac1d88] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 08/13/2021] [Indexed: 11/11/2022]
Abstract
The treatment of obesity based only on lifestyle changes has been shown ineffectiveness in a long-term period. The development of more definitive and non-invasive therapies has been the subject of study. In this paper, a magnetically driven ingestible capsule with the capacity to inflate a gastric balloon is devised, simulated, and fabricated. The balloon is inflated to a volume of 150 ml using an acid-base reaction between citric acid and potassium bicarbonate. Finite element method simulations were performed to study the interaction between the permanent external magnet and the ingestible capsule and confirm the magnetic activation mechanism. A fabrication process was proposed to manufacture a polydimethylsiloxane (PDMS) balloon in a simple, functional, and reproducible way. The two layers and 1:8 ratio balloons are the most cost-effective without compromising their mechanical properties. The capsule body parts manufactured by a three-dimensional (3D) printing process - Digital Light Processing (DLP) showed high accuracy and excellent resolution. This study demonstrated that the proposed ingestible capsule would successfully inflate the gastric balloon to treat obesity.
Collapse
Affiliation(s)
- R B Freitas
- CMEMS-UMinho, University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
| | - J A Rodrigues
- CMEMS-UMinho, University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
| | - H Puga
- CMEMS-UMinho, University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
| | - J H Correia
- CMEMS-UMinho, University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
| |
Collapse
|
9
|
Iacovacci V, Naselli I, Salgarella AR, Clemente F, Ricotti L, Cipriani C. Stability and in vivo safety of gold, titanium nitride and parylene C coatings on NdFeB magnets implanted in muscles towards a new generation of myokinetic prosthetic limbs. RSC Adv 2021; 11:6766-6775. [PMID: 35423178 PMCID: PMC8694929 DOI: 10.1039/d0ra07989h] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 01/31/2021] [Indexed: 01/11/2023] Open
Abstract
Rare earth magnets are the elective choice when high magnetic field density is required and they are particularly intriguing for inclusion in implantable devices. A safe implantation of NdFeB magnets in muscles would enable the control of limb prostheses using a myokinetic interface i.e., direct control of artificial limb movements by means of magnetic tracking of residual muscle contractions. However, myokinetic prosthesis control is prevented by NdFeB magnets poor biocompatibility, at present. Here we investigated three biocompatible materials as NdFeB magnet coating candidates, namely gold, titanium nitride and parylene C, which have not been analyzed in a systematic way for this purpose, so far. In vitro testing in a tissue-mimicking environment and upon contact with C2C12 myoblasts enabled assessment of the superiority of parylene C coated magnets in terms of corrosion prevention and lack of cytotoxicity. In addition, parylene C coated magnets implanted in rabbit muscles for 28 days confirmed, both locally and systemically, their biocompatibility, with a lack of irritation and toxicity associated with the implant. These findings pave the way towards the development of implantable devices based on permanent magnets and of a new generation of limb prostheses.
Collapse
Affiliation(s)
- Veronica Iacovacci
- The BioRobotics Institute, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
| | - Irene Naselli
- The BioRobotics Institute, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
| | - Alice Rita Salgarella
- The BioRobotics Institute, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
| | - Francesco Clemente
- The BioRobotics Institute, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
- Prensilia SRL Viale Rinaldo Piaggio 32 56025 Pontedera Italy
| | - Leonardo Ricotti
- The BioRobotics Institute, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
| | - Christian Cipriani
- The BioRobotics Institute, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
| |
Collapse
|
10
|
Saw WS, Anasamy T, Foo YY, Kwa YC, Kue CS, Yeong CH, Kiew LV, Lee HB, Chung LY. Delivery of Nanoconstructs in Cancer Therapy: Challenges and Therapeutic Opportunities. ADVANCED THERAPEUTICS 2021. [DOI: 10.1002/adtp.202000206] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Wen Shang Saw
- Department of Pharmaceutical Chemistry Faculty of Pharmacy University of Malaya Kuala Lumpur 50603 Malaysia
| | - Theebaa Anasamy
- Department of Pharmaceutical Chemistry Faculty of Pharmacy University of Malaya Kuala Lumpur 50603 Malaysia
| | - Yiing Yee Foo
- Department of Pharmacology Faculty of Medicine University of Malaya Kuala Lumpur 50603 Malaysia
| | - Yee Chu Kwa
- Department of Pharmaceutical Chemistry Faculty of Pharmacy University of Malaya Kuala Lumpur 50603 Malaysia
| | - Chin Siang Kue
- Department of Diagnostic and Allied Health Sciences Faculty of Health and Life Sciences Management and Science University Shah Alam Selangor 40100 Malaysia
| | - Chai Hong Yeong
- School of Medicine Faculty of Health and Medical Sciences Taylor's University Subang Jaya Selangor 47500 Malaysia
| | - Lik Voon Kiew
- Department of Pharmacology Faculty of Medicine University of Malaya Kuala Lumpur 50603 Malaysia
| | - Hong Boon Lee
- Department of Pharmaceutical Chemistry Faculty of Pharmacy University of Malaya Kuala Lumpur 50603 Malaysia
- School of Biosciences Faculty of Health and Medical Sciences Taylor's University Subang Jaya Selangor 47500 Malaysia
| | - Lip Yong Chung
- Department of Pharmaceutical Chemistry Faculty of Pharmacy University of Malaya Kuala Lumpur 50603 Malaysia
| |
Collapse
|
11
|
Ciuti G, Skonieczna-Żydecka K, Marlicz W, Iacovacci V, Liu H, Stoyanov D, Arezzo A, Chiurazzi M, Toth E, Thorlacius H, Dario P, Koulaouzidis A. Frontiers of Robotic Colonoscopy: A Comprehensive Review of Robotic Colonoscopes and Technologies. J Clin Med 2020; 9:E1648. [PMID: 32486374 PMCID: PMC7356873 DOI: 10.3390/jcm9061648] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/16/2020] [Accepted: 05/19/2020] [Indexed: 12/15/2022] Open
Abstract
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead.
Collapse
Affiliation(s)
- Gastone Ciuti
- The BioRobotics Institute, Scuola Superiore Sant’Anna, 56025 Pisa, Italy; (V.I.); (M.C.); (P.D.)
- Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
| | - Karolina Skonieczna-Żydecka
- Department of Human Nutrition and Metabolomics, Pomeranian Medical University in Szczecin, 71-460 Szczecin, Poland;
| | - Wojciech Marlicz
- Department of Gastroenterology, Pomeranian Medical University in Szczecin, 71-252 Szczecin, Poland;
- Endoklinika sp. z o.o., 70-535 Szczecin, Poland
| | - Veronica Iacovacci
- The BioRobotics Institute, Scuola Superiore Sant’Anna, 56025 Pisa, Italy; (V.I.); (M.C.); (P.D.)
- Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
| | - Hongbin Liu
- School of Biomedical Engineering & Imaging Sciences, Faculty of Life Sciences and Medicine, King’s College London, London SE1 7EH, UK;
| | - Danail Stoyanov
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London W1W 7TY, UK;
| | - Alberto Arezzo
- Department of Surgical Sciences, University of Torino, 10126 Torino, Italy;
| | - Marcello Chiurazzi
- The BioRobotics Institute, Scuola Superiore Sant’Anna, 56025 Pisa, Italy; (V.I.); (M.C.); (P.D.)
- Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
| | - Ervin Toth
- Department of Gastroenterology, Skåne University Hospital, Lund University, 20502 Malmö, Sweden;
| | - Henrik Thorlacius
- Department of Clinical Sciences, Section of Surgery, Lund University, 20502 Malmö, Sweden;
| | - Paolo Dario
- The BioRobotics Institute, Scuola Superiore Sant’Anna, 56025 Pisa, Italy; (V.I.); (M.C.); (P.D.)
- Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
| | | |
Collapse
|
12
|
A Development Study of a New Bi-directional Solenoid Actuator for Active Locomotion Capsule Robots. ELECTRONICS 2020. [DOI: 10.3390/electronics9050736] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A new bi-directional, simple-structured solenoid actuator for active locomotion capsule robots (CRs) is investigated in this paper. This active actuator consists of two permanent magnets (PMs) attached to the two ends of the capsule body and a vibration inner mass formed by a solenoidal coil with an iron core. The proposed CR, designed as a sealed structure without external legs, wheels, or caterpillars, can achieve both forward and backward motions driven by the internal collision force. This new design concept has been successfully confirmed on a capsule prototype. The measured displacements show that its movement can be easily controlled by changing the supplied current amplitude and frequency of the solenoid actuator. To validate the new bi-directional CR prototype, various experimental as well as finite element analysis results are presented in this paper.
Collapse
|
13
|
Bruns TL, Riojas KE, Ropella DS, Cavilla MS, Petruska AJ, Freeman MH, Labadie RF, Abbott JJ, Webster RJ. Magnetically Steered Robotic Insertion of Cochlear-Implant Electrode Arrays: System Integration and First-In-Cadaver Results. IEEE Robot Autom Lett 2020; 5:2240-2247. [PMID: 34621979 DOI: 10.1109/lra.2020.2970978] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Cochlear-implant electrode arrays (EAs) must be inserted accurately and precisely to avoid damaging the delicate anatomical structures of the inner ear. It has previously been shown on the benchtop that using magnetic fields to steer magnet-tipped EAs during insertion reduces insertion forces, which correlate with insertion errors and damage to internal cochlear structures. This paper presents several advancements toward the goal of deploying magnetic steering of cochlear-implant EAs in the operating room. In particular, we integrate image guidance with patient-specific insertion vectors, we incorporate a new nonmagnetic insertion tool, and we use an electromagnetic source, which provides programmable control over the generated field. The electromagnet is safer than prior permanent-magnet approaches in two ways: it eliminates motion of the field source relative to the patient's head and creates a field-free source in the power-off state. Using this system, we demonstrate system feasibility by magnetically steering EAs into a cadaver cochlea for the first time. We show that magnetic steering decreases average insertion forces, in comparison to manual insertions and to image-guided robotic insertions alone.
Collapse
Affiliation(s)
- Trevor L Bruns
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Katherine E Riojas
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Dominick S Ropella
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Matt S Cavilla
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Andrew J Petruska
- Department of Mechanical Engineering, Colorado School of Mines, Golden, CO, USA
| | - Michael H Freeman
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jake J Abbott
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Robert J Webster
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
14
|
Bianchi F, Masaracchia A, Shojaei Barjuei E, Menciassi A, Arezzo A, Koulaouzidis A, Stoyanov D, Dario P, Ciuti G. Localization strategies for robotic endoscopic capsules: a review. Expert Rev Med Devices 2019; 16:381-403. [PMID: 31056968 DOI: 10.1080/17434440.2019.1608182] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Affiliation(s)
- Federico Bianchi
- The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
| | | | | | | | - Alberto Arezzo
- Department of Surgical Sciences, University of Torino, Torino, Italy
| | | | - Danail Stoyanov
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK
| | - Paolo Dario
- The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
| | - Gastone Ciuti
- The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
| |
Collapse
|
15
|
Liu YL, Chen D, Shang P, Yin DC. A review of magnet systems for targeted drug delivery. J Control Release 2019; 302:90-104. [PMID: 30946854 DOI: 10.1016/j.jconrel.2019.03.031] [Citation(s) in RCA: 112] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 03/28/2019] [Accepted: 03/29/2019] [Indexed: 11/18/2022]
Abstract
Magnetic drug targeting is a method by which magnetic drug carriers in the body are manipulated by external magnetic fields to reach the target area. This method is potentially promising in applications for treatment of diseases like cancers, nervous system diseases, sudden sensorineural hearing loss, and so on, due to the advantages in that it can improve efficacy, reduce drug dosage and side effects. Therefore, it has received extensive attention in recent years. Successful magnetic drug targeting requires a good magnet system to guide the drug carriers to the target site. Up to date there have been many efforts to design the magnet systems for targeted drug delivery. However, there are few comprehensive reviews on these systems. Here we review the progresses made in this field. We summarized the systems already developed or proposed, and categorized them into two groups: static field magnet systems and varying field magnet systems. Based on the requirements for more powerful targeting performance, the prospects and the future research directions in this field are anticipated.
Collapse
Affiliation(s)
- Ya-Li Liu
- Institute for Special Environmental Biophysics, Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, PR China; Shenzhen Research Institute of Northwestern Polytechnical University, Shenzhen 518057, Guangzhou, PR China
| | - Da Chen
- Institute for Special Environmental Biophysics, Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, PR China
| | - Peng Shang
- Institute for Special Environmental Biophysics, Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, PR China; Shenzhen Research Institute of Northwestern Polytechnical University, Shenzhen 518057, Guangzhou, PR China
| | - Da-Chuan Yin
- Institute for Special Environmental Biophysics, Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, PR China; Shenzhen Research Institute of Northwestern Polytechnical University, Shenzhen 518057, Guangzhou, PR China.
| |
Collapse
|
16
|
Cohn D, Sloutski A, Elyashiv A, Varma VB, Ramanujan R. In Situ Generated Medical Devices. Adv Healthc Mater 2019; 8:e1801066. [PMID: 30828989 DOI: 10.1002/adhm.201801066] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 11/25/2018] [Indexed: 12/19/2022]
Abstract
Medical devices play a major role in all areas of modern medicine, largely contributing to the success of clinical procedures and to the health of patients worldwide. They span from simple commodity products such as gauzes and catheters, to highly advanced implants, e.g., heart valves and vascular grafts. In situ generated devices are an important family of devices that are formed at their site of clinical function that have distinct advantages. Among them, since they are formed within the body, they only require minimally invasive procedures, avoiding the pain and risks associated with open surgery. These devices also display enhanced conformability to local tissues and can reach sites that otherwise are inaccessible. This review aims at shedding light on the unique features of in situ generated devices and to underscore leading trends in the field, as they are reflected by key developments recently in the field over the last several years. Since the uniqueness of these devices stems from their in situ generation, the way they are formed is crucial. It is because of this fact that in this review, the medical devices are classified depending on whether their in situ generation entails chemical or physical phenomena.
Collapse
Affiliation(s)
- Daniel Cohn
- Casali Center of Applied ChemistryInstitute of ChemistryHebrew University of Jerusalem Jerusalem 91904 Israel
| | - Aaron Sloutski
- Casali Center of Applied ChemistryInstitute of ChemistryHebrew University of Jerusalem Jerusalem 91904 Israel
| | - Ariel Elyashiv
- Casali Center of Applied ChemistryInstitute of ChemistryHebrew University of Jerusalem Jerusalem 91904 Israel
| | - Vijaykumar B. Varma
- School of Materials Science and EngineeringNanyang Technological University 639798 Singapore Singapore
| | - Raju Ramanujan
- School of Materials Science and EngineeringNanyang Technological University 639798 Singapore Singapore
| |
Collapse
|
17
|
Scaglioni B, Fornarelli N, Garbin N, Menciassi A, Valdastri P. Independent Control of Multiple Degrees of Freedom Local Magnetic Actuators With Magnetic Cross-Coupling Compensation. IEEE Robot Autom Lett 2018. [DOI: 10.1109/lra.2018.2854921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
18
|
Do TN, Ho KY, Phee SJ. A Magnetic Soft Endoscopic Capsule-Inflated Intragastric Balloon for Weight Management. Sci Rep 2016; 6:39486. [PMID: 28000756 PMCID: PMC5175216 DOI: 10.1038/srep39486] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 11/21/2016] [Indexed: 02/06/2023] Open
Abstract
Overweight and obesity have been identified as a cause of high risk diseases like diabetes and cancer. Although conventional Intragastric Balloons (IGBs) have become an efficient and less invasive method for overweight and obesity treatment, the use of conventional tools such as catheter or endoscope to insert and remove the IGBs from the patient's body causes nausea, vomiting, discomfort, and even gastric mucous damage. To eliminate these drawbacks, we develop a novel magnetic soft capsule device with gas-filled balloon inflation. The balloon is made from a thin and biocompatible material that can be inflated to a desired volume using biocompatible effervescent chemicals. In addition, both the outer balloon and inner capsule are designed to be soft and chemical resistance. The soft capsule shell is fabricated using scaffold-solvent approach while the outer balloon utilizes a novel fabrication approach for 3D spherical structure. A prototype of the proposed capsule and balloon is given. Experiments are successfully carried out in stimulated gastric environment and fresh porcine stomach to validate the effectiveness and reliability of the proposed approach.
Collapse
Affiliation(s)
- Thanh Nho Do
- California NanoSystems Institute (CNSI), University of California, Santa Barbara, Room 2810, Elings Hall, Mesa Road, CA, 93106, USA
| | - Khek Yu Ho
- Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore and National University of Health System, 119260 Singapore
| | - Soo Jay Phee
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| |
Collapse
|
19
|
Mura M, Abu-Kheil Y, Ciuti G, Visentini-Scarzanella M, Menciassi A, Dario P, Dias J, Seneviratne L. Vision-based haptic feedback for capsule endoscopy navigation: a proof of concept. JOURNAL OF MICRO-BIO ROBOTICS 2016. [DOI: 10.1007/s12213-016-0090-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|