1
|
Gallez B. The Role of Imaging Biomarkers to Guide Pharmacological Interventions Targeting Tumor Hypoxia. Front Pharmacol 2022; 13:853568. [PMID: 35910347 PMCID: PMC9335493 DOI: 10.3389/fphar.2022.853568] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 06/23/2022] [Indexed: 12/12/2022] Open
Abstract
Hypoxia is a common feature of solid tumors that contributes to angiogenesis, invasiveness, metastasis, altered metabolism and genomic instability. As hypoxia is a major actor in tumor progression and resistance to radiotherapy, chemotherapy and immunotherapy, multiple approaches have emerged to target tumor hypoxia. It includes among others pharmacological interventions designed to alleviate tumor hypoxia at the time of radiation therapy, prodrugs that are selectively activated in hypoxic cells or inhibitors of molecular targets involved in hypoxic cell survival (i.e., hypoxia inducible factors HIFs, PI3K/AKT/mTOR pathway, unfolded protein response). While numerous strategies were successful in pre-clinical models, their translation in the clinical practice has been disappointing so far. This therapeutic failure often results from the absence of appropriate stratification of patients that could benefit from targeted interventions. Companion diagnostics may help at different levels of the research and development, and in matching a patient to a specific intervention targeting hypoxia. In this review, we discuss the relative merits of the existing hypoxia biomarkers, their current status and the challenges for their future validation as companion diagnostics adapted to the nature of the intervention.
Collapse
Affiliation(s)
- Bernard Gallez
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain (UCLouvain), Brussels, Belgium
| |
Collapse
|
2
|
Waller J, Onderdonk B, Flood A, Swartz H, Shah J, Shah A, Aydogan B, Halpern H, Hasan Y. The clinical utility of imaging methods used to measure hypoxia in cervical cancer. Br J Radiol 2020; 93:20190640. [PMID: 32286849 PMCID: PMC7336054 DOI: 10.1259/bjr.20190640] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 03/18/2020] [Accepted: 04/07/2020] [Indexed: 12/13/2022] Open
Abstract
While it is well-established that hypoxia is a major factor that affects clinical outcomes in cervical cancer, widespread usage of clinically available methods to detect and evaluate hypoxia during the course of treatment have not been established. This review compares these methods, summarizes their strengths and weaknesses, and assesses the pathways for their useful employment to alter clinical practice. We conducted a search on PubMed for literature pertaining to imaging hypoxic cervical cancer, and implemented keywords related to oxygen measurement tools to improve the relevance of the search results.Oxygenation level-dependent applications of MRI have demonstrated hypoxia-induced radioresistance, and changes in cervix tumor oxygenation from hyperoxic therapy.The hypoxic areas within tumors can be indirectly identified in dynamic contrast-enhanced images, where they generally display low signal enhancement, and diffusion-weighted images, which demonstrates areas of restricted diffusion (which correlates with hypoxia). Positron emmision tomography, used independently and with other imaging modalities, has demonstrated utility in imaging hypoxia through tracers specific for low oxygen levels, like Cu-ATSM tracers and nitroimidazoles. Detecting hypoxia in the tumors of patients diagnosed with cervical cancer via medical imaging and non-imaging tools like electron paramagnetic resonance oximetry can be utilized clinically, such as for guiding radiation and post-treatment surveillance, for a more personalized approach to treatment. The merits of these methods warrant further investigation via comparative effectiveness research and large clinical trials into their clinical applications.
Collapse
Affiliation(s)
- Joseph Waller
- Drexel College of Medicine, 2900 W Queen Ln, PA 19129, United States
| | - Benjamin Onderdonk
- Department of Radiation and Cellular Oncology, The University of Chicago, 5758 S Maryland Ave, IL 60637, United States
| | - Ann Flood
- Department of Radiology, Dartmouth Geisel School of Medicine, 1 Rope Ferry Rd, NH 03755, United States
| | - Harold Swartz
- Department of Radiology, Dartmouth Geisel School of Medicine, 1 Rope Ferry Rd, NH 03755, United States
| | - Jaffer Shah
- Drexel College of Medicine, 2900 W Queen Ln, PA 19129, United States
| | - Asghar Shah
- Brown University, Providence, RI 02912, United States
| | - Bulent Aydogan
- Department of Radiation and Cellular Oncology, The University of Chicago, 5758 S Maryland Ave, IL 60637, United States
| | - Howard Halpern
- Department of Radiation and Cellular Oncology, The University of Chicago, 5758 S Maryland Ave, IL 60637, United States
| | - Yasmin Hasan
- Department of Radiation and Cellular Oncology, The University of Chicago, 5758 S Maryland Ave, IL 60637, United States
| |
Collapse
|
3
|
Polacco MA, Hou H, Kuppusamy P, Chen EY. Measuring Flap Oxygen Using Electron Paramagnetic Resonance Oximetry. Laryngoscope 2019; 129:E415-E419. [PMID: 31034638 DOI: 10.1002/lary.28043] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 04/03/2019] [Accepted: 04/15/2019] [Indexed: 12/18/2022]
Abstract
OBJECTIVES/HYPOTHESIS To determine if electron paramagnetic resonance (EPR) oximetry is a viable technology to aid in flap monitoring. STUDY DESIGN Prospective cohort. METHODS This was a cohort study assessing accuracy and speed of EPR oximetry in detecting ischemia of a saphenous artery-based flap in a rat model, using transcutaneous oximetry as a control. Measurements were obtained under both resting and ischemic conditions for nine Sprague Dawley rats (18 flaps), for 3 postoperative days following flap elevation. RESULTS The mean partial pressure of oxygen prior to tourniquet application was 66.9 ± 8.9 mm Hg with EPR oximetry and 64.7 ± 5.2 mm Hg with transcutaneous oximetry (P = .45). Mean partial pressures of oxygen during tourniquet application were 8.9 ± 3.2 mm Hg and 8.5 ± 2.9 mm Hg for EPR oximetry and transcutaneous oximetry, respectively (P = .48), and 67.2 ± 6.9 mm Hg and 65.3 ± 6.1 mm Hg after tourniquet release for EPR oximetry and transcutaneous oximetry, respectively (P = .44). The mean ischemia detection time of EPR oximetry was 49 ± 21 seconds. CONCLUSIONS Offering timely, accurate, and noninvasive tissue oxygen measurements, EPR oximetry is a promising adjunct in flap monitoring. LEVEL OF EVIDENCE NA Laryngoscope, 129:E415-E419, 2019.
Collapse
Affiliation(s)
- Marc A Polacco
- Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| | - Huagang Hou
- Brigham and Women's Hospital, Boston, Massachusetts
| | | | - Eunice Y Chen
- Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| |
Collapse
|
4
|
Hou H, Khan N, Gohain S, Eskey CJ, Moodie KL, Maurer KJ, Swartz HM, Kuppusamy P. Dynamic EPR Oximetry of Changes in Intracerebral Oxygen Tension During Induced Thromboembolism. Cell Biochem Biophys 2017; 75:285-294. [PMID: 28434138 DOI: 10.1007/s12013-017-0798-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 04/12/2017] [Indexed: 12/19/2022]
Abstract
Cerebral tissue oxygenation (oxygen tension, pO2) is a critical parameter that is closely linked to brain metabolism, function, and pathophysiology. In this work, we have used electron paramagnetic resonance oximetry with a deep-tissue multi-site oxygen-sensing probe, called implantable resonator, to monitor temporal changes in cerebral pO2 simultaneously at four sites in a rabbit model of ischemic stroke induced by embolic clot. The pO2 values in healthy brain were not significantly different among the four sites measured over a period of 4 weeks. During exposure to 15% O2 (hypoxia), a sudden and significant decrease in pO2 was observed in all four sites. On the other hand, brief exposure to breathing carbogen gas (95% O2 + 5% CO2) showed a significant increase in the cerebral pO2 from baseline value. During ischemic stroke, induced by embolic clot in the left brain, a significant decline in the pO2 of the left cortex (ischemic core) was observed without any change in the contralateral sites. While the pO2 in the non-infarct regions returned to baseline at 24-h post-stroke, pO2 in the infarct core was consistently lower compared to the baseline and other regions of the brain. The results demonstrated that electron paramagnetic resonance oximetry with the implantable resonator can repeatedly and simultaneously report temporal changes in cerebral pO2 at multiple sites. This oximetry approach can be used to develop interventions to rescue hypoxic/ischemic tissue by modulating cerebral pO2 during hypoxic and stroke injury.
Collapse
Affiliation(s)
- Huagang Hou
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Nadeem Khan
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Sangeeta Gohain
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Clifford J Eskey
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Karen L Moodie
- Center for Comparative Medicine and Research, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Kirk J Maurer
- Center for Comparative Medicine and Research, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Harold M Swartz
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Periannan Kuppusamy
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA.
| |
Collapse
|
5
|
Frank J, Gündel D, Drescher S, Thews O, Mäder K. Injectable LiNc-BuO loaded microspheres as in vivo EPR oxygen sensors after co-implantation with tumor cells. Free Radic Biol Med 2015; 89:741-9. [PMID: 26459034 DOI: 10.1016/j.freeradbiomed.2015.10.401] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 10/03/2015] [Accepted: 10/08/2015] [Indexed: 10/22/2022]
Abstract
Electron paramagnetic resonance (EPR) oximetry is a technique which allows accurate and repeatable oxygen measurements. We encapsulated a highly oxygen sensitive particulate EPR spin probe into microparticles to improve its dispersibility and, hence, facilitate the administration. These biocompatible, non-toxic microspheres contained 5-10 % (w/w) spin probe and had an oxygen sensitivity of 0.60 ± 0.01 µT/mmHg. To evaluate the performance of the microparticles as oxygen sensors, they were co-implanted with syngeneic tumor cells in 2 different rat strains. Thus, tissue injury was avoided and the microparticles were distributed all over the tumor tissue. Dynamic changes of the intratumoral oxygen partial pressure during inhalation of 8 %, 21 %, or 100 % oxygen were monitored in vivo by EPR spectroscopy and quantified. Values were verified in vivo by invasive fluorometric measurements using Oxylite probes and ex vivo by pimonidazole adduct accumulation. There were no hints that the tumor physiology or tissue oxygenation had been altered by the microparticles. Hence, these microprobes offer great potential as oxygen sensors in preclinical research, not only for EPR spectroscopy but also for EPR imaging. For instance, the assessment of tissue oxygenation during therapeutic interventions might help understanding pathophysiological processes and lead to an individualized treatment planning or the use of formulations with hypoxia triggered release of active agents.
Collapse
Affiliation(s)
- Juliane Frank
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale), Germany
| | - Daniel Gündel
- Julius-Bernstein-Institute of Physiology, Martin Luther University Halle-Wittenberg, Magdeburger Str. 6, 06112 Halle (Saale), Germany
| | - Simon Drescher
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale), Germany
| | - Oliver Thews
- Julius-Bernstein-Institute of Physiology, Martin Luther University Halle-Wittenberg, Magdeburger Str. 6, 06112 Halle (Saale), Germany.
| | - Karsten Mäder
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale), Germany.
| |
Collapse
|
6
|
Khan N, Hou H, Swartz HM, Kuppusamy P. Direct and Repeated Measurement of Heart and Brain Oxygenation Using In Vivo EPR Oximetry. Methods Enzymol 2015; 564:529-52. [PMID: 26477264 DOI: 10.1016/bs.mie.2015.06.023] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Low level of oxygen (hypoxia) is a critical factor that defines the pathological consequence of several pathophysiologies, particularly ischemia, that usually occur following the blockage of a blood vessel in vital organs, such as brain and heart, or abnormalities in the microvasculature, such as peripheral vascular disease. Therefore, methods that can directly and repeatedly quantify oxygen levels in the brain and heart will significantly improve our understanding of ischemic pathologies. Importantly, such oximetry capability will facilitate the development of strategies to counteract low levels of oxygen and thereby improve outcome following stroke or myocardial infarction. In vivo electron paramagnetic resonance (EPR) oximetry has the capability to monitor tissue oxygen levels in real time. The method has largely been tested and used in experimental animals, although some clinical measurements have been performed. In this chapter, a brief overview of the methodology to repeatedly quantify oxygen levels in the brain and heart of experimental animal models, ranging from mice to swine, is presented. EPR oximetry requires a one-time placement of an oxygen-sensitive probe in the tissue of interest, while the rest of the procedure for reliable, accurate, and repeated measurements of pO2 (partial pressure of oxygen) is noninvasive and can be repeated as often as desired. A multisite oximetry approach can be used to monitor pO2 at many sites simultaneously. Building on significant advances in the application of EPR oximetry in experimental animal models, spectrometers have been developed for use in human subjects. Initial feasibility of pO2 measurement in solid tumors of patients has been successfully demonstrated.
Collapse
Affiliation(s)
- Nadeem Khan
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA
| | - Huagang Hou
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA
| | - Harold M Swartz
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA
| | - Periannan Kuppusamy
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.
| |
Collapse
|
7
|
Abstract
The mass transport or flux of neurochemicals in the brain and how this flux affects chemical measurements and their interpretation is reviewed. For all endogenous neurochemicals found in the brain, the flux of each of these neurochemicals exists between sources that produce them and the sites that consume them all within μm distances. Principles of convective-diffusion are reviewed with a significant emphasis on the tortuous paths and discrete point sources and sinks. The fundamentals of the primary methods of detection, microelectrodes and microdialysis sampling of brain neurochemicals are included in the review. Special attention is paid to the change in the natural flux of the neurochemicals caused by implantation and consumption at microelectrodes and uptake by microdialysis. The detection of oxygen, nitric oxide, glucose, lactate, and glutamate, and catecholamines by both methods are examined and where possible the two techniques (electrochemical vs. microdialysis) are compared. Non-invasive imaging methods: magnetic resonance, isotopic fluorine MRI, electron paramagnetic resonance, and positron emission tomography are also used for different measurements of the above-mentioned solutes and these are briefly reviewed. Although more sophisticated, the imaging techniques are unable to track neurochemical flux on short time scales, and lack spatial resolution. Where possible, determinations of flux using imaging are compared to the more classical techniques of microdialysis and microelectrodes.
Collapse
Affiliation(s)
- David W Paul
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR 72701, USA.
| | | |
Collapse
|
8
|
Noninvasive monitoring of small intestinal oxygen in a rat model of chronic mesenteric ischemia. Cell Biochem Biophys 2014; 67:451-9. [PMID: 23636684 DOI: 10.1007/s12013-013-9611-y] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
We noninvasively monitored the partial pressure of oxygen (pO2) in rat's small intestine using a model of chronic mesenteric ischemia by electron paramagnetic resonance oximetry over a 7-day period. The particulate probe lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) was embedded into the oxygen permeable material polydimethyl siloxane by cast-molding and polymerization (Oxy-Chip). A one-time surgical procedure was performed to place the Oxy-Chip on the outer wall of the small intestine (SI). The superior mesenteric artery (SMA) was banded to ~30% of blood flow for experimental rats. Noninvasive measurement of pO2 was performed at the baseline for control rats or immediate post-banding and on days 1, 3, and 7. The SI pO2 for control rats remained stable over the 7-day period. The pO2 on day-7 was 54.5 ± 0.9 mmHg (mean ± SE). SMA-banded rats were significantly different from controls with a noted reduction in pO2 post banding with a progressive decline to a final pO2 of 20.9 ± 4.5 mmHg (mean ± SE; p = 0.02). All SMA-banded rats developed adhesions around the Oxy-Chip, yet remained asymptomatic. The hypoxia marker Hypoxyprobe™ was used to validate the low tissue pO2. Brown cytoplasmic staining was consistent with hypoxia. Mild brown staining was noted predominantly on the villus tips in control animals. SMA-banded rats had an extended region of hypoxic involvement in the villus with a higher intensity of cytoplasmic staining. Deep brown stainings of the enteric nervous system neurons and connective tissue both within layers and in the mesentery were noted. SMA-banded rats with lower pO2 values had a higher intensity of staining. Thus, monitoring SI pO2 using the probe Oxy-Chip provides a valid measure of tissue oxygenation. Tracking pO2 in conditions that produce chronic mesenteric ischemia will contribute to our understanding of intestinal tissue oxygenation and how changes impact symptom evolution and the trajectory of chronic disease.
Collapse
|
9
|
Swartz HM, Williams BB, Zaki BI, Hartford AC, Jarvis LA, Chen EY, Comi RJ, Ernstoff MS, Hou H, Khan N, Swarts SG, Flood AB, Kuppusamy P. Clinical EPR: unique opportunities and some challenges. Acad Radiol 2014; 21:197-206. [PMID: 24439333 DOI: 10.1016/j.acra.2013.10.011] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/03/2013] [Accepted: 10/14/2013] [Indexed: 11/29/2022]
Abstract
Electron paramagnetic resonance (EPR) spectroscopy has been well established as a viable technique for measurement of free radicals and oxygen in biological systems, from in vitro cellular systems to in vivo small animal models of disease. However, the use of EPR in human subjects in the clinical setting, although attractive for a variety of important applications such as oxygen measurement, is challenged with several factors including the need for instrumentation customized for human subjects, probe, and regulatory constraints. This article describes the rationale and development of the first clinical EPR systems for two important clinical applications, namely, measurement of tissue oxygen (oximetry) and radiation dose (dosimetry) in humans. The clinical spectrometers operate at 1.2 GHz frequency and use surface-loop resonators capable of providing topical measurements up to 1 cm depth in tissues. Tissue pO2 measurements can be carried out noninvasively and repeatedly after placement of an oxygen-sensitive paramagnetic material (currently India ink) at the site of interest. Our EPR dosimetry system is capable of measuring radiation-induced free radicals in the tooth of irradiated human subjects to determine the exposure dose. These developments offer potential opportunities for clinical dosimetry and oximetry, which include guiding therapy for individual patients with tumors or vascular disease by monitoring of tissue oxygenation. Further work is in progress to translate this unique technology to routine clinical practice.
Collapse
Affiliation(s)
- Harold M Swartz
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766.
| | - Benjamin B Williams
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Bassem I Zaki
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Alan C Hartford
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Lesley A Jarvis
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Eunice Y Chen
- Department of Surgery, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Richard J Comi
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Marc S Ernstoff
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Huagang Hou
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Nadeem Khan
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Steven G Swarts
- Dept. of Radiation Oncology, University of Florida, Gainesville, FL
| | - Ann B Flood
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Periannan Kuppusamy
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| |
Collapse
|
10
|
Liu XB, Cheng Q, Geng W, Ling CC, Liu Y, Ng KTP, Yam JWP, Guan XY, Lo CM, Man K. Enhancement of cisplatin-based TACE by a hemoglobin-based oxygen carrier in an orthotopic rat HCC model. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2013; 42:229-36. [DOI: 10.3109/21691401.2013.808647] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
11
|
Tran LBA, Bol A, Labar D, Jordan B, Magat J, Mignion L, Grégoire V, Gallez B. Hypoxia imaging with the nitroimidazole 18F-FAZA PET tracer: a comparison with OxyLite, EPR oximetry and 19F-MRI relaxometry. Radiother Oncol 2012; 105:29-35. [PMID: 22677038 DOI: 10.1016/j.radonc.2012.04.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2011] [Revised: 04/02/2012] [Accepted: 04/16/2012] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND PURPOSE (18)F-FAZA is a nitroimidazole PET tracer that can provide images of tumor hypoxia. However, it cannot provide absolute pO(2) values. To qualify (18)F-FAZA PET, we compared PET images to pO(2) measured by OxyLite, EPR oximetry and (19)F-MRI. MATERIALS AND METHODS Male WAG/Rij rats grafted with rhabdomyosarcoma were used. Tumor oxygenation was modified by gas breathing (air or carbogen). The same day of PET acquisition, the pO(2) was measured in the same tumor either by OxyLite probes (measurement at 10 different sites), EPR oximetry using low frequency EPR or (19)F-relaxometry using 15C5 on an 11.7T MR system. RESULTS There was a good correlation between the results obtained by PET and EPR (R = 0.93). In the case of OxyLite, although a weaker correlation was observed (R = 0.55), the trend for two values to agree was still related to the inverse function theoretically predicted. For the comparison of (18)F-FAZA PET and (19)F-MRI, no change in T(1) was observed. CONCLUSIONS A clear correlation between (18)F-FAZA PET image intensities and tumor oxygenation was demonstrated, suggesting that (18)F-FAZA PET is a promising imaging technique to guide cancer therapy.
Collapse
Affiliation(s)
- Ly-Binh-An Tran
- Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Selvendiran K, Bratasz A, Kuppusamy ML, Tazi MF, Rivera BK, Kuppusamy P. Hypoxia induces chemoresistance in ovarian cancer cells by activation of signal transducer and activator of transcription 3. Int J Cancer 2009; 125:2198-204. [PMID: 19623660 PMCID: PMC2893222 DOI: 10.1002/ijc.24601] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Signal transducer and activator of transcription 3 (STAT3) is activated in a variety of human cancers, including ovarian cancer. The molecular mechanism by which the STAT3 is activated in cancer cells is poorly understood. We observed that human ovarian xenograft tumors (A2780) in mice were severely hypoxic (pO(2) approximately 2 mmHg). We further observed that hypoxic exposure significantly increased the phosphorylation of STAT3 (pSTAT3) at the Tyr705 residue in A2780 cell line. The pSTAT3 (Tyr705) level was highly dependent on cellular oxygenation levels, with a significant increase at <2% O(2), and without any change in the pSTAT3 (Ser727) or total STAT3 levels. The pSTAT3 (Tyr705) elevation following hypoxic exposure could be reversed within 12 hr after returning the cells to normoxia. The increased level of pSTAT3 was partly mediated by increased levels of reactive oxygen species generation in the hypoxic cancer cells. Conventional chemotherapeutic drugs cisplatin and taxol were far less effective in eliminating the hypoxic ovarian cancer cells suggesting a role for pSTAT3 in cellular resistance to chemotherapy. Inhibition of STAT3 by AG490 followed by treatment with cisplatin or taxol resulted in a significant increase in apoptosis suggesting that hypoxia-induced STAT3 activation is responsible for chemoresistance. The results have important clinical implications for the treatment of hypoxic ovarian tumors using STAT3-specific inhibitors.
Collapse
Affiliation(s)
| | - Anna Bratasz
- Department of Internal Medicine, Ohio State University, Columbus, OH
| | | | - Mia F. Tazi
- Department of Internal Medicine, Ohio State University, Columbus, OH
| | - Brian K. Rivera
- Department of Internal Medicine, Ohio State University, Columbus, OH
| | | |
Collapse
|
13
|
Vikram DS, Ahmad R, Pandian RP, Petryakov S, Kuppusamy P. Evaluation of oxygen-response times of phthalocyanine-based crystalline paramagnetic spin probes for EPR oximetry. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 193:127-32. [PMID: 18479953 PMCID: PMC2722937 DOI: 10.1016/j.jmr.2008.04.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 01/26/2008] [Revised: 04/09/2008] [Accepted: 04/24/2008] [Indexed: 05/26/2023]
Abstract
The goal of the present study was to evaluate the temporal response of particulate-based EPR oximetry probes to changes in partial pressure of oxygen (pO(2)). In order to accurately evaluate the oxygen-response time, we developed a method for rapid modulation of pO(2) in a chamber containing the probe using an oscillator-driven speaker-diaphragm setup. The apparatus was capable of producing sinusoidal changes in pO(2) at frequencies up to 300 Hz or more. The pressure-modulation setup was used to evaluate the temporal response of some of the most commonly used phthalocyanine-based particulate probes. For validation, the time-response of the probes was compared to that of a high sensitivity pressure sensor. The results revealed that some particulate probes could respond to changes in pO(2) with a temporal response of 3.3 ms (300 Hz). The observations were interpreted in the light of their crystalline packing in favor of oxygen diffusion. The results of the present study should enable the selection of probes for oximetry applications requiring high temporal resolution.
Collapse
Affiliation(s)
- Deepti S. Vikram
- Center for Biomedical EPR Spectroscopy and Imaging, The Dorothy M. Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, 420 West 12th Avenue, TMRF-114, Columbus, OH 43210, USA
| | - Rizwan Ahmad
- Center for Biomedical EPR Spectroscopy and Imaging, The Dorothy M. Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, 420 West 12th Avenue, TMRF-114, Columbus, OH 43210, USA
| | - Ramasamy P. Pandian
- Center for Biomedical EPR Spectroscopy and Imaging, The Dorothy M. Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, 420 West 12th Avenue, TMRF-114, Columbus, OH 43210, USA
| | - Sergey Petryakov
- Center for Biomedical EPR Spectroscopy and Imaging, The Dorothy M. Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, 420 West 12th Avenue, TMRF-114, Columbus, OH 43210, USA
| | - Periannan Kuppusamy
- Center for Biomedical EPR Spectroscopy and Imaging, The Dorothy M. Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, 420 West 12th Avenue, TMRF-114, Columbus, OH 43210, USA
| |
Collapse
|